1
|
Mutlu O, Mazhar N, Saribay M, Yavuz MM, Ozturk D, Ghareeb AN, Alnabti A, Yalcin HC. Finite Element Analysis of Evolut Transcatheter Heart Valves: Effects of Aortic Geometries and Valve Sizes on Post-TAVI Wall Stresses and Deformations. J Clin Med 2025; 14:850. [PMID: 39941521 PMCID: PMC11818669 DOI: 10.3390/jcm14030850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2024] [Revised: 01/12/2025] [Accepted: 01/17/2025] [Indexed: 02/16/2025] Open
Abstract
Background/Objectives: For transcatheter aortic valve implantation (TAVI) therapy, a catheter-guided crimped valve is deployed into the aortic root. Valve types such as Edwards balloon-expandable valves and Medtronic self-expandable valves come in different sizes and are chosen based on patient-specific aortic anatomy, including aortic root diameter measurement. Complications may arise due to variations in anatomical characteristics and the implantation procedure, making pre-implantation assessment important for predicting complications. Methods: Computational modeling, particularly finite element analysis (FEA), has become popular for assessing wall stresses and deformations in TAVI. In this study, a finite element model including the aorta, native leaflets, and TAVI device was used to simulate procedures and assess patient-specific wall stresses and deformations. Results: Using the Medtronic Evolut R valve, we simulated TAVI for 14 patients to analyze the effects of geometrical variations on structural stresses. Virtual TAVIs with different valve sizes were also simulated to study the influence of TAV size on stresses. Our results show that variations in aortic wall geometries and TAV sizes significantly influence wall stresses and deformations. Conclusions: Our study is one of the first comprehensive FEA investigations of aortic geometrical variations and valve sizes on post-TAVI stresses, demonstrating the non-linear relationship between aortic dimensions, TAV sizes, and wall stresses.
Collapse
Affiliation(s)
- Onur Mutlu
- Biomedical Research Center, QU Health, Qatar University, Doha 2713, Qatar; (O.M.); (N.M.)
| | - Noaman Mazhar
- Biomedical Research Center, QU Health, Qatar University, Doha 2713, Qatar; (O.M.); (N.M.)
| | - Murat Saribay
- Mechanical Engineering Department, Istanbul Bilgi University, Istanbul 34050, Turkey;
| | - Mehmet Metin Yavuz
- Mechanical Engineering Department, Middle East Technical University, Ankara 06800, Turkey;
| | | | - Abdel Naser Ghareeb
- Heart Hospital, Hamad Medical Corporation, Doha 3050, Qatar;
- Faculty of Medicine, Al Azhar University, Cairo 11884, Egypt
| | | | - Huseyin Cagatay Yalcin
- Biomedical Research Center, QU Health, Qatar University, Doha 2713, Qatar; (O.M.); (N.M.)
- Department of Biomedical Science, College of Health Sciences, QU Health, Qatar University, Doha 2713, Qatar
- Department of Mechanical and Industrial Engineering, Qatar University, Doha 2713, Qatar
| |
Collapse
|
2
|
Scuoppo R, Cannata S, Gandolfo C, Bellavia D, Pasta S. On the accuracy of the segmentation process and transcatheter heart valve dimensions in TAVI patients. J Biomech 2024; 176:112357. [PMID: 39369627 DOI: 10.1016/j.jbiomech.2024.112357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2024] [Revised: 09/14/2024] [Accepted: 10/01/2024] [Indexed: 10/08/2024]
Abstract
Accurate segmentation of medical images is critical for generating patient-specific models suitable for computational analyses, particularly in the context of transcatheter aortic valve implantation (TAVI). This study aimed to quantify the accuracy of the segmentation process from medical images of TAVI patients to understand the uncertainty in patient-specific geometries. We also quantified discrepancies between actual and CT-related diameter measurements due to artifacts and intra-observer variability. Segmentation accuracy was assessed using both synthetic phantom models and patient-specific data. The impact of voxelization and CT scanner resolution on segmentation accuracy was evaluated, while the intersection over union (IoU) metric was used to compare the consistency of different segmentation methodologies. The voxelization process introduced a marginal error (<1%) in phantom models relative to CAD models. CT scanner resolution impacted segmented model accuracy only after a 7.5-fold increase in voxel size compared to the baseline medical image. IoU analysis revealed higher segmentation accuracy for calcification (93.4 ± 3.1 %) compared to the aortic wall (85.4 ± 8.4 %) and native valve leaflets (75.5 ± 6.3 %). Discrepancies in THV diameter measurements highlighted a ∼5 % error due to metallic artifacts, with variability among observers and at different THV heights. Errors due to voxel size, segmentation methodologies and CT-related artifacts can impact the reliability of patient-specific geometries and ultimately computational predictions used to asses clinical outcomes and enhance decision-making. This study underscores the importance of accurate segmentation and its standardization for patient-specific modeling of TAVI simulations.
Collapse
Affiliation(s)
- Roberta Scuoppo
- Department of Engineering, Università degli Studi di Palermo, Viale delle Scienze Ed.8, Palermo, Italy
| | - Stefano Cannata
- Department for the Treatment and Study of Cardiothoracic Diseases and Cardiothoracic Transplantation, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta Specializzazione), Palermo, Italy
| | - Caterina Gandolfo
- Department for the Treatment and Study of Cardiothoracic Diseases and Cardiothoracic Transplantation, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta Specializzazione), Palermo, Italy
| | - Diego Bellavia
- Department of Research, IRCCS ISMETT via Tricomi, 5, Palermo, Italy
| | - Salvatore Pasta
- Department of Engineering, Università degli Studi di Palermo, Viale delle Scienze Ed.8, Palermo, Italy; Department of Research, IRCCS ISMETT via Tricomi, 5, Palermo, Italy.
| |
Collapse
|
3
|
Mutlu O, Saribay M, Yavuz MM, Salman HE, Al-Nabti ARDMH, Yalcin HC. Material modeling and recent findings in transcatheter aortic valve implantation simulations. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 255:108314. [PMID: 39024970 DOI: 10.1016/j.cmpb.2024.108314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 06/12/2024] [Accepted: 06/28/2024] [Indexed: 07/20/2024]
Abstract
BACKGROUND AND OBJECTIVE Transcatheter aortic valve implantation (TAVI) has significantly transformed the management of aortic valve (AV) diseases, presenting a minimally invasive option compared to traditional surgical valve replacement. Computational simulations of TAVI become more popular and offer a detailed investigation by employing patient-specific models. On the other hand, employing accurate material modeling procedures and applying basic modeling steps are crucial to determining reliable numerical results. Therefore, this review aims to outline the basic modeling approaches for TAVI, focusing on material modeling and geometry extraction, as well as summarizing the important findings from recent computational studies to guide future research in the field. METHODS This paper explains the basic steps and important points in setting up and running TAVI simulations. The material properties of the leaflets, valves, stents, and tissues utilized in TAVI simulations are provided, along with a comprehensive explanation of the geometric extraction methods employed. The differences between the finite element analysis, computational fluid dynamics, and fluid-structure interaction approaches are pointed out and the important aspects of TAVI modeling are described by elucidating the recent computational studies. RESULTS The results of the recent findings on TAVI simulations are summarized to demonstrate its powerful potential. It is observed that the material properties of aortic tissues and components of implanted valves should be modeled realistically to determine accurate results. For patient-specific AV geometries, incorporating calcific deposits on the leaflets is essential for ensuring the accuracy of computational findings. The results of numerical TAVI simulations indicate the significance of the selection of optimal valves and precise deployment within the appropriate anatomical position. These factors collectively contribute to the effective functionality of the implanted valve. CONCLUSIONS Recent studies in the literature have revealed the critical importance of patient-specific modeling, the selection of accurate material models, and bio-prosthetic valve diameters. Additionally, these studies emphasize the necessity of precise positioning of bio-prosthetic valves to achieve optimal performance in TAVI, characterized by an increased effective orifice area and minimal paravalvular leakage.
Collapse
Affiliation(s)
- Onur Mutlu
- Qatar University, Biomedical Research Center, Doha, Qatar
| | - Murat Saribay
- Istanbul Bilgi University, Mechanical Engineering Department, Istanbul, Turkey
| | - Mehmet Metin Yavuz
- Middle East Technical University, Mechanical Engineering Department, Ankara, Turkey
| | - Huseyin Enes Salman
- TOBB University of Economics and Technology, Department of Mechanical Engineering, Ankara, Turkey
| | | | - Huseyin Cagatay Yalcin
- Qatar University, Biomedical Research Center, Doha, Qatar; Department of Biomedical Science, College of Health Sciences, QU Health, Qatar University, Doha, Qatar.
| |
Collapse
|
4
|
Singh R, Chandi SK, Sran S, Aulakh SK, Nijjar GS, Singh K, Singh S, Tanvir F, Kaur Y, Sandhu APS. Emerging Therapeutic Strategies in Cardiovascular Diseases. Cureus 2024; 16:e64388. [PMID: 39131016 PMCID: PMC11317025 DOI: 10.7759/cureus.64388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/12/2024] [Indexed: 08/13/2024] Open
Abstract
Cardiovascular diseases (CVDs), including ischemic heart disease and stroke, are the leading cause of mortality worldwide, causing nearly 20 million deaths annually. Traditional therapies, while effective, have not curbed the rising prevalence of CVDs driven by aging populations and lifestyle factors. This review highlights innovative therapeutic strategies that show promise in improving patient outcomes and transforming cardiovascular care. Emerging pharmacological treatments, such as proprotein convertase subtilisin/kexin type 9 (PCSK9) inhibitors and sodium-glucose co-transporter 2 (SGLT2) inhibitors, introduce novel mechanisms to complement existing therapies, significantly reducing cardiovascular events and mortality. These advancements emphasize the necessity of ongoing clinical trials and research to discover new therapeutic targets. Advanced biological therapies, including gene therapy, stem cell therapy, and RNA-based treatments, offer groundbreaking potential for repairing and regenerating damaged cardiovascular tissues. Despite being in various stages of clinical validation, early results are promising, suggesting these therapies could fundamentally change the CVD treatment landscape. Innovative medical devices and technologies, such as implantable devices, minimally invasive procedures, and wearable technology, are revolutionizing CVD management. These advancements facilitate early diagnosis, continuous monitoring, and effective treatment, driving care out of hospitals and into homes, improving patient outcomes and reducing healthcare costs. Personalized medicine, driven by genetic profiling and biomarker identification, allows for tailored therapies that enhance treatment efficacy and minimize adverse effects. However, the adoption of these emerging therapies faces significant challenges, including regulatory hurdles, cost and accessibility issues, and ethical considerations. Addressing these barriers and fostering interdisciplinary collaboration are crucial for accelerating the development and implementation of innovative treatments. Integrating emerging therapeutic strategies in cardiovascular care holds immense potential to transform CVD management. By prioritizing future research and overcoming existing challenges, a new era of personalized, effective, and accessible cardiovascular care can be achieved.
Collapse
Affiliation(s)
- Rajinderpal Singh
- Internal Medicine, Government Medical College Amritsar, Amritsar, IND
| | | | - Seerat Sran
- Internal Medicine, Sri Guru Ram Das University of Health Sciences and Research, Amritsar, IND
| | - Smriti K Aulakh
- Internal Medicine, Sri Guru Ram Das University of Health Sciences and Research, Amritsar, IND
| | | | | | - Sumerjit Singh
- Medicine, Government Medical College Amritsar, Amritsar, IND
| | - Fnu Tanvir
- Medicine, Government Medical College Amritsar, Amritsar, IND
| | - Yasmeen Kaur
- Medicine, Government Medical College Amritsar, Amritsar, IND
| | - Ajay Pal Singh Sandhu
- Medicine, Sri Guru Ram Das University of Health Sciences and Research, Amritsar, IND
| |
Collapse
|
5
|
Baylous K, Helbock R, Kovarovic B, Anam S, Slepian M, Bluestein D. In silico fatigue optimization of TAVR stent designs with physiological motion in a beating heart model. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 243:107886. [PMID: 37925854 DOI: 10.1016/j.cmpb.2023.107886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 10/17/2023] [Accepted: 10/21/2023] [Indexed: 11/07/2023]
Abstract
BACKGROUND AND OBJECTIVE The rapid expansion of TAVR to younger, low-risk patients raises concerns regarding device durability. Necessarily, extended stent lifetime will become more critical for new generation devices. In vitro methods commonly used for TAVR stent fatigue testing exclude the effects of the beating heart. We present a more realistic in silico stent fatigue analysis utilizing a beating heart model in which TAVR stents experience complex, nonuniform dynamic loading. METHODS Virtual TAVR deployments were simulated in the SIMULIA Living Heart Human Model of a beating heart using stent models of the self-expandable nitinol 26-mm CoreValve and Evolut R devices, and a 27-mm PolyV-2. Stent deformation was monitored over three cardiac cycles, and fatigue resistance was evaluated for the nitinol stents using finite element analysis via ABAQUS/Explicit. The average strain and strain amplitude of each stent element were tracked, and established thresholds were applied to determine potential fatigue failure. Fatigue performance of control stents was compared to parametrically modified models with a 20% increase or decrease in strut width. RESULTS Stents with reduced strut width applied lower radial force against the contracting myocardium of the beating heart, resulting in larger displacements and higher strain values. Formulas relating in vivo strain to stent design do not account for this. In all models, there were elements in which strains exceeded fatigue failure. The PolyV-2 stent had far fewer failing elements since its struts were optimized to reduce the strain in stent joints, achieving better fatigue resistance in the stent crown and waist elements. Different stent sections showed markedly different fatigue resistance due to the varying loading conditions. CONCLUSIONS Our analysis indicates that previous studies underestimate strain amplitudes that may cause stent failure. This study demonstrates the utility of advanced in silico analysis of devices deployed within a beating heart that mimics in vivo loading, offering a cost-effective alternative to human or animal trials and establishing a platform to assess the impact of device design on device durability. The limited fatigue life of TAVR stents indicated here highlights a clinical complication that may eventually develop as younger, lower-risk TAVR patients, age.
Collapse
Affiliation(s)
- Kyle Baylous
- Department of Biomedical Engineering, Stony Brook University, Health Sciences Center, Stony Brook, NY 11794-8084, USA
| | - Ryan Helbock
- Department of Biomedical Engineering, Stony Brook University, Health Sciences Center, Stony Brook, NY 11794-8084, USA
| | - Brandon Kovarovic
- Department of Biomedical Engineering, Stony Brook University, Health Sciences Center, Stony Brook, NY 11794-8084, USA
| | - Salwa Anam
- Department of Biomedical Engineering, Stony Brook University, Health Sciences Center, Stony Brook, NY 11794-8084, USA
| | - Marvin Slepian
- Department of Medicine and Biomedical Engineering Sarver Heart Center, University of Arizona, Tucson, AZ 85721, USA
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Health Sciences Center, Stony Brook, NY 11794-8084, USA.
| |
Collapse
|
6
|
Wilson SI, Ingram KE, Oh A, Moreno MR, Kassi M. The role of innovative modeling and imaging techniques in improving outcomes in patients with LVAD. Front Cardiovasc Med 2023; 10:1248300. [PMID: 37692033 PMCID: PMC10484111 DOI: 10.3389/fcvm.2023.1248300] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 08/10/2023] [Indexed: 09/12/2023] Open
Abstract
Heart failure remains a significant cause of mortality in the United States and around the world. While organ transplantation is acknowledged as the gold standard treatment for end stage heart failure, supply is limited, and many patients are treated with left ventricular assist devices (LVADs). LVADs extend and improve patients' lives, but they are not without their own complications, particularly the hemocompatibility related adverse events (HRAE) including stroke, bleeding and pump thrombosis. Mainstream imaging techniques currently in use to assess appropriate device function and troubleshoot complications, such as echocardiography and cardiac computed tomography, provide some insight but do not provide a holistic understanding of pump induced flow alterations that leads to HRAEs. In contrast, there are technologies restricted to the benchtop-such as computational fluid dynamics and mock circulatory loops paired with methods like particle image velocimetry-that can assess flow metrics but have not been optimized for clinical care. In this review, we outline the potential role and current limitations of converging available technologies to produce novel imaging techniques, and the potential utility in evaluating hemodynamic flow to determine whether LVAD patients may be at higher risk of HRAEs. This addition to diagnostic and monitoring capabilities could improve prevention and treatment of LVAD-induced complications in heart failure patients.
Collapse
Affiliation(s)
- Shannon I. Wilson
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, United States
| | - Katelyn E. Ingram
- DeBakey Heart and Vascular- Heart Center Research, Houston Methodist Research Institute, Houston, TX, United States
| | - Albert Oh
- School of Engineering Medicine, Texas A&M University, Houston, TX, United States
| | - Michael R. Moreno
- J. Mike Walker ‘66 Department of Mechanical Engineering, Texas A&M University, College Station, TX, United States
| | - Mahwash Kassi
- Cardiology, DeBakey Heart and Vascular, Houston Methodist Hospital, Houston, TX, United States
| |
Collapse
|
7
|
Tahir AM, Mutlu O, Bensaali F, Ward R, Ghareeb AN, Helmy SMHA, Othman KT, Al-Hashemi MA, Abujalala S, Chowdhury MEH, Alnabti ARDMH, Yalcin HC. Latest Developments in Adapting Deep Learning for Assessing TAVR Procedures and Outcomes. J Clin Med 2023; 12:4774. [PMID: 37510889 PMCID: PMC10381346 DOI: 10.3390/jcm12144774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 04/08/2023] [Accepted: 04/10/2023] [Indexed: 07/30/2023] Open
Abstract
Aortic valve defects are among the most prevalent clinical conditions. A severely damaged or non-functioning aortic valve is commonly replaced with a bioprosthetic heart valve (BHV) via the transcatheter aortic valve replacement (TAVR) procedure. Accurate pre-operative planning is crucial for a successful TAVR outcome. Assessment of computational fluid dynamics (CFD), finite element analysis (FEA), and fluid-solid interaction (FSI) analysis offer a solution that has been increasingly utilized to evaluate BHV mechanics and dynamics. However, the high computational costs and the complex operation of computational modeling hinder its application. Recent advancements in the deep learning (DL) domain can offer a real-time surrogate that can render hemodynamic parameters in a few seconds, thus guiding clinicians to select the optimal treatment option. Herein, we provide a comprehensive review of classical computational modeling approaches, medical imaging, and DL approaches for planning and outcome assessment of TAVR. Particularly, we focus on DL approaches in previous studies, highlighting the utilized datasets, deployed DL models, and achieved results. We emphasize the critical challenges and recommend several future directions for innovative researchers to tackle. Finally, an end-to-end smart DL framework is outlined for real-time assessment and recommendation of the best BHV design for TAVR. Ultimately, deploying such a framework in future studies will support clinicians in minimizing risks during TAVR therapy planning and will help in improving patient care.
Collapse
Affiliation(s)
- Anas M Tahir
- Electrical and Computer Engineering Department, The University of British Columbia, Vancouver, BC V6T 1Z4, Canada
- Biomedical Research Center, Qatar University, Doha 2713, Qatar
| | - Onur Mutlu
- Biomedical Research Center, Qatar University, Doha 2713, Qatar
| | - Faycal Bensaali
- Department of Electrical Engineering, Qatar University, Doha 2713, Qatar
| | - Rabab Ward
- Electrical and Computer Engineering Department, The University of British Columbia, Vancouver, BC V6T 1Z4, Canada
| | - Abdel Naser Ghareeb
- Heart Hospital, Hamad Medical Corporation, Doha 3050, Qatar
- Faculty of Medicine, Al Azhar University, Cairo 11884, Egypt
| | - Sherif M H A Helmy
- Noninvasive Cardiology Section, Cardiology Department, Heart Hospital, Hamad Medical Corporation, Doha 3050, Qatar
| | | | - Mohammed A Al-Hashemi
- Noninvasive Cardiology Section, Cardiology Department, Heart Hospital, Hamad Medical Corporation, Doha 3050, Qatar
| | | | | | | | - Huseyin C Yalcin
- Biomedical Research Center, Qatar University, Doha 2713, Qatar
- Department of Biomedical Science, College of Health Sciences, QU Health, Qatar University, Doha 2713, Qatar
| |
Collapse
|
8
|
Karakoç A, Aksoy O, Taciroğlu E. Effects of leaflet curvature and thickness on the crimping stresses in transcatheter heart valve. J Biomech 2023; 156:111663. [PMID: 37295168 DOI: 10.1016/j.jbiomech.2023.111663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 05/04/2023] [Accepted: 05/23/2023] [Indexed: 06/12/2023]
Abstract
With the current advances and expertise in biomedical device technologies, transcatheter heart valves (THVs) have been drawing significant attention. Various studies have been carried out on their durability and damage by dynamic loading in operational conditions. However, very few numerical investigations have been conducted to understand the effects of leaflet curvature and thickness on the crimping stresses which arise during the surgical preparation processes. In order to contribute to the current state of the art, a full heart valve model was presented, the leaflet curvature and thickness of which were then parameterized so as to understand the stress generation as a result of the crimping procedure during the surgical preparations. The results show that the existence of stresses is inevitable during the crimping procedure, which is a reduction factor for valve durability. Especially, stresses on the leaflets at the suture sites connected with the skirt were deduced to be critical and may result in leaflet ruptures after THV implantation.
Collapse
Affiliation(s)
- Alp Karakoç
- Aalto University, Department of Communications and Networking, 02150, Finland; Department of Civil and Environmental Engineering, University of California, Los Angeles, 90095, USA.
| | - Olcay Aksoy
- Division of Cardiology, Department of Medicine, University of California, Los Angeles, 90095, USA
| | - Ertuğrul Taciroğlu
- Department of Civil and Environmental Engineering, University of California, Los Angeles, 90095, USA
| |
Collapse
|
9
|
Huang X, Zhang G, Zhou X, Yang X. A review of numerical simulation in transcatheter aortic valve replacement decision optimization. Clin Biomech (Bristol, Avon) 2023; 106:106003. [PMID: 37245279 DOI: 10.1016/j.clinbiomech.2023.106003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 05/08/2023] [Accepted: 05/15/2023] [Indexed: 05/30/2023]
Abstract
BACKGROUND Recent trials indicated a further expansion of clinical indication of transcatheter aortic valve replacement to younger and low-risk patients. Factors related to longer-term complications are becoming more important for use in these patients. Accumulating evidence indicates that numerical simulation plays a significant role in improving the outcome of transcatheter aortic valve replacement. Understanding mechanical features' magnitude, pattern, and duration is a topic of ongoing relevance. METHODS We searched the PubMed database using keywords such as "transcatheter aortic valve replacement" and "numerical simulation" and reviewed and summarized relevant literature. FINDINGS This review integrated recently published evidence into three subtopics: 1) prediction of transcatheter aortic valve replacement outcomes through numerical simulation, 2) implications for surgeons, and 3) trends in transcatheter aortic valve replacement numerical simulation. INTERPRETATIONS Our study offers a comprehensive overview of the utilization of numerical simulation in the context of transcatheter aortic valve replacement, and highlights the advantages, potential challenges from a clinical standpoint. The convergence of medicine and engineering plays a pivotal role in enhancing the outcomes of transcatheter aortic valve replacement. Numerical simulation has provided evidence of potential utility for tailored treatments.
Collapse
Affiliation(s)
- Xuan Huang
- Department of Cardiovascular Surgery, West China Biomedical Big Data Center, West China Hospital/West China School of Medicine, Sichuan University, Chengdu, Sichuan, China; Med-X Center for Informatics, Sichuan University, Chengdu, Sichuan, China
| | - Guangming Zhang
- Center for Computational Systems Medicine, School of Biomedical Informatics, The University of Texas Health Science Center at Houston, Houston, TX 77030, USA
| | - Xiaobo Zhou
- Center for Computational Systems Medicine, School of Biomedical Informatics, The University of Texas Health Science Center at Houston, Houston, TX 77030, USA; McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX 77030, USA; School of Dentistry, The University of Texas Health Science Center at Houston, Houston, TX 77030, USA
| | - Xiaoyan Yang
- Department of Cardiovascular Surgery, West China Biomedical Big Data Center, West China Hospital/West China School of Medicine, Sichuan University, Chengdu, Sichuan, China; Med-X Center for Informatics, Sichuan University, Chengdu, Sichuan, China.
| |
Collapse
|
10
|
Helbock RT, Anam SB, Kovarovic BJ, Slepian MJ, Hamdan A, Haj-Ali R, Bluestein D. Designing a Novel Asymmetric Transcatheter Aortic Valve for Stenotic Bicuspid Aortic Valves Using Patient-Specific Computational Modeling. Ann Biomed Eng 2023; 51:58-70. [PMID: 36042099 DOI: 10.1007/s10439-022-03039-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 07/25/2022] [Indexed: 01/13/2023]
Abstract
Bicuspid aortic valve (BAV), the most common congenital heart malformation, is characterized by the presence of only two valve leaflets with asymmetrical geometry, resulting in elliptical systolic opening. BAV often leads to early onset of calcific aortic stenosis (AS). Following the rapid expansion of transcatheter aortic valve replacement (TAVR), designed specifically for treating conventional tricuspid AS, BAV patients with AS were initially treated "off-label" with TAVR, which recently gained FDA and CE regulatory approval. Despite its increasing use in BAV, pathological BAV anatomy often leads to complications stemming from mismatched anatomical features. To mitigate these complications, a novel eccentric polymeric TAVR valve incorporating asymmetrical leaflets was designed specifically for BAV anatomies. Computational modeling was used to optimize its asymmetric leaflets for lower functional stresses and improved hemodynamic performance. Deployment and flow were simulated in patient-specific BAV models (n = 6) and compared to a current commercial TAVR valve (Evolut R 29 mm), to assess deployment and flow parameters. The novel eccentric BAV-dedicated valve demonstrated significant improvements in peak systolic orifice area, along with lower jet velocity and wall shear stress (WSS). This feasibility study demonstrates the clinical potential of the first known BAV-dedicated TAVR design, which will foster advancement of patient-dedicated valvular devices.
Collapse
Affiliation(s)
- Ryan T Helbock
- Biofluids Research Group, Department of Biomedical Engineering, T8-050 Health Sciences Center, Stony Brook University, Stony Brook, NY11794-8084, USA
| | - Salwa B Anam
- Biofluids Research Group, Department of Biomedical Engineering, T8-050 Health Sciences Center, Stony Brook University, Stony Brook, NY11794-8084, USA
| | - Brandon J Kovarovic
- Biofluids Research Group, Department of Biomedical Engineering, T8-050 Health Sciences Center, Stony Brook University, Stony Brook, NY11794-8084, USA
| | - Marvin J Slepian
- Department of Medicine and Biomedical Engineering Sarver Heart Center, University of Arizona, Tucson, AZ, 85721, USA
| | - Ashraf Hamdan
- Department of Cardiology, Rabin Medical Center, 4941492, Petah Tikva, Israel
| | - Rami Haj-Ali
- School of Mechanical Engineering, Faculty of Engineering, Tel Aviv University, 69978, Tel Aviv, Ramat Aviv, Israel
| | - Danny Bluestein
- Biofluids Research Group, Department of Biomedical Engineering, T8-050 Health Sciences Center, Stony Brook University, Stony Brook, NY11794-8084, USA.
| |
Collapse
|
11
|
Anam SB, Kovarovic BJ, Ghosh RP, Bianchi M, Hamdan A, Haj-Ali R, Bluestein D. Validating In Silico and In Vitro Patient-Specific Structural and Flow Models with Transcatheter Bicuspid Aortic Valve Replacement Procedure. Cardiovasc Eng Technol 2022; 13:840-856. [PMID: 35391657 DOI: 10.1007/s13239-022-00620-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Accepted: 03/28/2022] [Indexed: 01/27/2023]
Abstract
INTRODUCTION Bicuspid aortic valve (BAV) is the most common congenital cardiac malformation, which had been treated off-label by transcatheter aortic valve replacement (TAVR) procedure for several years, until its recent approval by the Food and Drug Administration (FDA) and Conformité Européenne (CE) to treat BAVs. Post-TAVR complications tend to get exacerbated in BAV patients due to their inherent aortic root pathologies. Globally, due to the paucity of randomized clinical trials, clinicians still favor surgical AVR as the primary treatment option for BAV patients. While this warrants longer term studies of TAVR outcomes in BAV patient cohorts, in vitro experiments and in silico computational modeling can be used to guide the surgical community in assessing the feasibility of TAVR in BAV patients. Our goal is to combine these techniques in order to create a modeling framework for optimizing pre-procedural planning and minimize post-procedural complications. MATERIALS AND METHODS Patient-specific in silico models and 3D printed replicas of 3 BAV patients with different degrees of post-TAVR paravalvular leakage (PVL) were created. Patient-specific TAVR device deployment was modeled in silico and in vitro-following the clinical procedures performed in these patients. Computational fluid dynamics simulations and in vitro flow studies were performed in order to obtain the degrees of PVL in these models. RESULTS PVL degree and locations were consistent with the clinical data. Cross-validation comparing the stent deformation and the flow parameters between the in silico and the in vitro models demonstrated good agreement. CONCLUSION The current framework illustrates the potential of using simulations and 3D printed models for pre-TAVR planning and assessing post-TAVR complications in BAV patients.
Collapse
Affiliation(s)
- Salwa B Anam
- Biofluids Research Group, Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - Brandon J Kovarovic
- Biofluids Research Group, Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - Ram P Ghosh
- Biofluids Research Group, Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - Matteo Bianchi
- Biofluids Research Group, Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - Ashraf Hamdan
- Department of Cardiology, Rabin Medical Center, 4941492, Petah Tikva, Israel
| | - Rami Haj-Ali
- School of Mechanical Engineering, Faculty of Engineering, Tel Aviv University, Ramat Aviv, 69978, Tel Aviv, Israel
| | - Danny Bluestein
- Biofluids Research Group, Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA. .,Department of Biomedical Engineering, Stony Brook University, T8-050 Health Sciences Center, Stony Brook, NY, 11794-8084, USA.
| |
Collapse
|
12
|
Fragmentation of Different Calcification Growth Patterns in Bicuspid Valves During Balloon Valvuloplasty Procedure. Ann Biomed Eng 2022; 51:1014-1027. [PMID: 36451023 DOI: 10.1007/s10439-022-03115-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 11/24/2022] [Indexed: 12/05/2022]
Abstract
This study focuses on the calcification development and routes of type-1 bicuspid aortic valves based on CT scans and the effect of the unique geometrical shapes of calcium deposits on their fragmentation under balloon valvuloplasty procedures. Towards this goal, the novel Reverse Calcification Technique (RCT), which can predict the calcification progression leading to the current state based on CT scans, is utilized for n = 26 bicuspid aortic valves patients. Two main calcification patterns of type-1 bicuspid aortic valves were identified; asymmetric and symmetric with either partial or full arcs and circles. Subsequently, a calcification fragmentation biomechanical model was introduced to study the balloon valvuloplasty procedure prior to transcatheter aortic valve replacement implantation that allows better device expansion. To achieve this goal, six representative stenotic bicuspid aortic valves of different calcification patterns were investigated. It was found that the distinct geometrical shape of the calcium deposits had a significant effect on the cracks' initiations. Full or partial circle deposits had stronger resistance to fragmentation and mainly remained intact, yet, arc-shaped pattern deposits resulted in multiple cracks in bottleneck regions. The proposed biomechanical computational models could help assess calcification fragmentation patterns toward improving treatment approaches in stenotic bicuspid aortic valve patients, particularly for the off-label use of transcatheter aortic valve replacement.
Collapse
|
13
|
Nappi F, Avtaar Singh SS, Nappi P, Fiore A. Biomechanics of Transcatheter Aortic Valve Implant. Bioengineering (Basel) 2022; 9:299. [PMID: 35877350 PMCID: PMC9312295 DOI: 10.3390/bioengineering9070299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 06/28/2022] [Accepted: 06/29/2022] [Indexed: 11/16/2022] Open
Abstract
Transcatheter aortic valve implantation (TAVI) has grown exponentially within the cardiology and cardiac surgical spheres. It has now become a routine approach for treating aortic stenosis. Several concerns have been raised about TAVI in comparison to conventional surgical aortic valve replacement (SAVR). The primary concerns regard the longevity of the valves. Several factors have been identified which may predict poor outcomes following TAVI. To this end, the lesser-used finite element analysis (FEA) was used to quantify the properties of calcifications which affect TAVI valves. This method can also be used in conjunction with other integrated software to ascertain the functionality of these valves. Other imaging modalities such as multi-detector row computed tomography (MDCT) are now widely available, which can accurately size aortic valve annuli. This may help reduce the incidence of paravalvular leaks and regurgitation which may necessitate further intervention. Structural valve degeneration (SVD) remains a key factor, with varying results from current studies. The true incidence of SVD in TAVI compared to SAVR remains unclear due to the lack of long-term data. It is now widely accepted that both are part of the armamentarium and are not mutually exclusive. Decision making in terms of appropriate interventions should be undertaken via shared decision making involving heart teams.
Collapse
Affiliation(s)
- Francesco Nappi
- Department of Cardiac Surgery, Centre Cardiologique du Nord, 93200 Saint-Denis, France
| | | | - Pierluigi Nappi
- Department of Clinical and Experimental Medicine, University of Messina, 98122 Messina, Italy;
| | - Antonio Fiore
- Department of Cardiac Surgery, Hôpitaux Universitaires Henri Mondor, Assistance Publique-Hôpitaux de Paris, 94000 Creteil, France;
| |
Collapse
|
14
|
Yao J, Bosi GM, Burriesci G, Wurdemann H. Computational Analysis of Balloon Catheter Behaviour at Variable Inflation Levels. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:3015-3019. [PMID: 36083934 DOI: 10.1109/embc48229.2022.9871164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Aortic valvuloplasty is a minimally invasive procedure for the dilatation of stenotic aortic valves. Rapid ventricular pacing is an established technique for balloon stabilization during this procedure. However, low cardiac output due to the pacing is one of the inherent risks, which is also associated with several potential complications. This paper proposes a numerical modelling approach to understand the effect of different inflation levels of a valvuloplasty balloon catheter on the positional instability caused by a pulsating blood flow. An unstretched balloon catheter model was crimped into a tri-folded configuration and inflated to several levels. Ten different inflation levels were then tested, and a Fluid-Structure Interaction model was built to solve interactions between the balloon and the blood flow modelled in an idealised aortic arch. Our computational results show that the maximum displacement of the balloon catheter increases with the inflation level, with a small step at around 50% inflation and a sharp increase after reaching 85% inflation. This work represents a substantial progress towards the use of simulations to solve the interactions between a balloon catheter and pulsating blood flow.
Collapse
|
15
|
Dowling C, Gooley R, McCormick L, Rashid HN, Dargan J, Khan F, Firoozi S, Brecker SJ. Patient-Specific Computer Simulation to Predict Conduction Disturbance With Current-Generation Self-Expanding Transcatheter Heart Valves. STRUCTURAL HEART : THE JOURNAL OF THE HEART TEAM 2022; 6:100010. [PMID: 37274548 PMCID: PMC10236875 DOI: 10.1016/j.shj.2022.100010] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 01/19/2022] [Accepted: 02/02/2022] [Indexed: 10/18/2022]
Abstract
Background Patient-specific computer simulation may predict the development of conduction disturbance following transcatheter aortic valve replacement (TAVR). Validation of the computer simulations with current-generation devices has not been undertaken. Methods A retrospective study was performed on patients who had undergone TAVR with a current-generation self-expanding transcatheter heart valve (THV). Preprocedural computed tomography imaging was used to create finite element models of the aortic root. Procedural contrast angiography was reviewed, and finite element analysis performed using a matching THV device size and implantation depth. A region of interest corresponding to the atrioventricular bundle and proximal left bundle branch was identified. The percentage of this area (contact pressure index [CPI]) and maximum contact pressure (CPMax) exerted by THV were recorded. Postprocedural electrocardiograms were reviewed, and major conduction disturbance was defined as the development of persistent left bundle branch block or high-degree atrioventricular block. Results A total of 80 patients were included in the study. THVs were 23- to 29-mm Evolut PRO (n = 53) and 34-mm Evolut R (n = 27). Major conduction disturbance occurred in 27 patients (33.8%). CPI (28.3 ± 15.8 vs. 15.6 ± 11.2%; p < 0.001) and CPMax (0.51 ± 0.20 vs. 0.36 ± 0.24 MPa; p = 0.008) were higher in patients who developed major conduction disturbance. CPI (area under the receiver operating characteristic curve [AUC], 0.74; 95% CI, 0.63-0.86; p < 0.001) and CPMax (AUC, 0.69; 95% CI, 0.57-0.81; p = 0.006) demonstrated a discriminatory power to predict the development of major conduction disturbance. Conclusions Patient-specific computer simulation may identify patients at risk for conduction disturbance after TAVR with current-generation self-expanding THVs.
Collapse
Affiliation(s)
- Cameron Dowling
- MonashHeart, Monash Health and Monash Cardiovascular Research Centre, Monash University, Melbourne, Australia
| | - Robert Gooley
- MonashHeart, Monash Health and Monash Cardiovascular Research Centre, Monash University, Melbourne, Australia
| | - Liam McCormick
- MonashHeart, Monash Health and Monash Cardiovascular Research Centre, Monash University, Melbourne, Australia
| | - Hashrul N. Rashid
- MonashHeart, Monash Health and Monash Cardiovascular Research Centre, Monash University, Melbourne, Australia
| | - James Dargan
- Cardiovascular Clinical Academic Group, St. George’s, University of London and St. George’s University Hospitals NHS Foundation Trust, London, UK
| | - Faisal Khan
- Cardiovascular Clinical Academic Group, St. George’s, University of London and St. George’s University Hospitals NHS Foundation Trust, London, UK
| | - Sami Firoozi
- Cardiovascular Clinical Academic Group, St. George’s, University of London and St. George’s University Hospitals NHS Foundation Trust, London, UK
| | - Stephen J. Brecker
- Cardiovascular Clinical Academic Group, St. George’s, University of London and St. George’s University Hospitals NHS Foundation Trust, London, UK
| |
Collapse
|
16
|
Appa H, Park K, Bezuidenhout D, van Breda B, de Jongh B, de Villiers J, Chacko R, Scherman J, Ofoegbu C, Swanevelder J, Cousins M, Human P, Smith R, Vogt F, Podesser BK, Schmitz C, Conradi L, Treede H, Schröfel H, Fischlein T, Grabenwöger M, Luo X, Coombes H, Matskeplishvili S, Williams DF, Zilla P. The Technological Basis of a Balloon-Expandable TAVR System: Non-occlusive Deployment, Anchorage in the Absence of Calcification and Polymer Leaflets. Front Cardiovasc Med 2022; 9:791949. [PMID: 35310972 PMCID: PMC8928444 DOI: 10.3389/fcvm.2022.791949] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2021] [Accepted: 01/18/2022] [Indexed: 12/14/2022] Open
Abstract
Leaflet durability and costs restrict contemporary trans-catheter aortic valve replacement (TAVR) largely to elderly patients in affluent countries. TAVR that are easily deployable, avoid secondary procedures and are also suitable for younger patients and non-calcific aortic regurgitation (AR) would significantly expand their global reach. Recognizing the reduced need for post-implantation pacemakers in balloon-expandable (BE) TAVR and the recent advances with potentially superior leaflet materials, a trans-catheter BE-system was developed that allows tactile, non-occlusive deployment without rapid pacing, direct attachment of both bioprosthetic and polymer leaflets onto a shape-stabilized scallop and anchorage achieved by plastic deformation even in the absence of calcification. Three sizes were developed from nickel-cobalt-chromium MP35N alloy tubes: Small/23 mm, Medium/26 mm and Large/29 mm. Crimp-diameters of valves with both bioprosthetic (sandwich-crosslinked decellularized pericardium) and polymer leaflets (triblock polyurethane combining siloxane and carbonate segments) match those of modern clinically used BE TAVR. Balloon expansion favors the wing-structures of the stent thereby creating supra-annular anchors whose diameter exceeds the outer diameter at the waist level by a quarter. In the pulse duplicator, polymer and bioprosthetic TAVR showed equivalent fluid dynamics with excellent EOA, pressure gradients and regurgitation volumes. Post-deployment fatigue resistance surpassed ISO requirements. The radial force of the helical deployment balloon at different filling pressures resulted in a fully developed anchorage profile of the valves from two thirds of their maximum deployment diameter onwards. By combining a unique balloon-expandable TAVR system that also caters for non-calcific AR with polymer leaflets, a powerful, potentially disruptive technology for heart valve disease has been incorporated into a TAVR that addresses global needs. While fulfilling key prerequisites for expanding the scope of TAVR to the vast number of patients of low- to middle income countries living with rheumatic heart disease the system may eventually also bring hope to patients of high-income countries presently excluded from TAVR for being too young.
Collapse
Affiliation(s)
- Harish Appa
- Strait Access Technologies (SAT), University of Cape Town, Cape Town, South Africa
| | - Kenneth Park
- Strait Access Technologies (SAT), University of Cape Town, Cape Town, South Africa
| | - Deon Bezuidenhout
- Strait Access Technologies (SAT), University of Cape Town, Cape Town, South Africa
- Cardiovascular Research Unit, University of Cape Town, Cape Town, South Africa
| | - Braden van Breda
- Strait Access Technologies (SAT), University of Cape Town, Cape Town, South Africa
| | - Bruce de Jongh
- Strait Access Technologies (SAT), University of Cape Town, Cape Town, South Africa
| | - Jandré de Villiers
- Strait Access Technologies (SAT), University of Cape Town, Cape Town, South Africa
| | - Reno Chacko
- Strait Access Technologies (SAT), University of Cape Town, Cape Town, South Africa
| | - Jacques Scherman
- Cardiovascular Research Unit, University of Cape Town, Cape Town, South Africa
- Chris Barnard Division for Cardiothoracic Surgery, University of Cape Town, Cape Town, South Africa
| | - Chima Ofoegbu
- Cardiovascular Research Unit, University of Cape Town, Cape Town, South Africa
- Chris Barnard Division for Cardiothoracic Surgery, University of Cape Town, Cape Town, South Africa
| | - Justiaan Swanevelder
- Department of Anaesthesia and Perioperative Medicine, University of Cape Town, Cape Town, South Africa
| | - Michael Cousins
- Strait Access Technologies (SAT), University of Cape Town, Cape Town, South Africa
| | - Paul Human
- Cardiovascular Research Unit, University of Cape Town, Cape Town, South Africa
- Chris Barnard Division for Cardiothoracic Surgery, University of Cape Town, Cape Town, South Africa
| | - Robin Smith
- Strait Access Technologies (SAT), University of Cape Town, Cape Town, South Africa
| | - Ferdinand Vogt
- Deparment of Cardiac Surgery, Artemed Clinic Munich South, Munich, Germany
- Department of Cardiac Surgery, Klinikum Nürnberg, Paracelsus Medical University, Nuremberg, Germany
| | - Bruno K. Podesser
- Center for Biomedical Research, Medical University of Vienna, Vienna, Austria
| | - Christoph Schmitz
- Auto Tissue Berlin, Berlin, Germany
- Department of Cardiac Surgery, University of Munich, Munich, Germany
| | - Lenard Conradi
- Department of Cardiovascular Surgery, University Heart Center, Hamburg, Germany
| | - Hendrik Treede
- Department of Cardiac and Vascular Surgery, University Hospital, Mainz, Germany
| | - Holger Schröfel
- Department of Cardiovascular Surgery, University Heart Center, Freiburg, Germany
| | - Theodor Fischlein
- Department of Cardiac Surgery, Klinikum Nürnberg, Paracelsus Medical University, Nuremberg, Germany
| | - Martin Grabenwöger
- Department of Cardiovascular Surgery, Vienna North Hospital, Vienna, Austria
| | - Xinjin Luo
- Department of Cardiac Sugery, Fu Wai Hospital, Peking Union Medical College, Beijing, China
| | - Heather Coombes
- Strait Access Technologies (SAT), University of Cape Town, Cape Town, South Africa
| | | | - David F. Williams
- Strait Access Technologies (SAT), University of Cape Town, Cape Town, South Africa
- Wake Forest Institute of Regenerative Medicine, Wake Forest School of Medicine, Winston-Salem, NC, United States
| | - Peter Zilla
- Strait Access Technologies (SAT), University of Cape Town, Cape Town, South Africa
- Cardiovascular Research Unit, University of Cape Town, Cape Town, South Africa
- Chris Barnard Division for Cardiothoracic Surgery, University of Cape Town, Cape Town, South Africa
- Cape Heart Centre, University of Cape Town, Cape Town, South Africa
| |
Collapse
|
17
|
Reza S, Bianchi M, Kovarovic B, Anam S, Slepian MJ, Hamdan A, Haj-Ali R, Bluestein D. A computational framework for post-TAVR cardiac conduction abnormality (CCA) risk assessment in patient-specific anatomy. Artif Organs 2022; 46:1305-1317. [PMID: 35083748 DOI: 10.1111/aor.14189] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 12/14/2021] [Accepted: 01/18/2022] [Indexed: 11/27/2022]
Abstract
BACKGROUND Cardiac conduction abnormality (CCA)- one of the major persistent complications associated with transcatheter aortic valve replacement (TAVR) may lead to permanent pacemaker implantation. Localized stresses exerted by the device frame on the membranous septum (MS) which lies between the aortic annulus and the bundle of His, may disturb the cardiac conduction and cause the resultant CCA. We hypothesize that the area-weighted average maximum principal logarithmic strain (AMPLS) in the MS region can predict the risk of CCA following TAVR. METHODS Rigorous finite element-based modeling analysis was conducted in two patients (Balloon expandable TAVR recipients) to assess post-TAVR CCA risk. Following the procedure one of the patients required permanent pacemaker (PPM) implantation while the other did not (control case). Patient-specific aortic root was modeled, MS was identified from the CT image, and the TAVR deployment was simulated. Mechanical factors in the MS region such as logarithmic strain, contact force, contact pressure, contact pressure index (CPI) and their time history during the TAVR deployment; and anatomical factors such as MS length, implantation depth, were analyzed. RESULTS Maximum AMPLS (0.47 and 0.37, respectively), contact force (0.92 N and 0.72 N, respectively), and CPI (3.99 and 2.86, respectively) in the MS region were significantly elevated in the PPM patient as compared to control patient. CONCLUSION Elevated stresses generated by TAVR devices during deployment appear to correlate with CCA risk, with AMPLS in the MS region emerging as a strong predictor that could be used for preprocedural planning in order to minimize CCA risk.
Collapse
Affiliation(s)
- Symon Reza
- Department of Biomedical Engineering, Stony Brook University, NY, USA
| | - Matteo Bianchi
- Department of Biomedical Engineering, Stony Brook University, NY, USA
| | - Brandon Kovarovic
- Department of Biomedical Engineering, Stony Brook University, NY, USA
| | - Salwa Anam
- Department of Biomedical Engineering, Stony Brook University, NY, USA
| | - Marvin J Slepian
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, USA
| | - Ashraf Hamdan
- Department of Cardiology, Rabin Medical Center, Faculty of Medicine, Tel-Aviv University, Tel Aviv, Israel
| | - Rami Haj-Ali
- The Fleischman Faculty of Engineering, School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Ramat Aviv, Israel
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, NY, USA
| |
Collapse
|
18
|
Assessment of Paravalvular Leak Severity and Thrombogenic Potential in Transcatheter Bicuspid Aortic Valve Replacements Using Patient-Specific Computational Modeling. J Cardiovasc Transl Res 2021; 15:834-844. [PMID: 34859367 PMCID: PMC9160219 DOI: 10.1007/s12265-021-10191-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Accepted: 11/22/2021] [Indexed: 12/12/2022]
Abstract
Bicuspid aortic valve (BAV), the most common congenital valvular abnormality, generates asymmetric flow patterns and increased stresses on the leaflets that expedite valvular calcification and structural degeneration. Recently adapted for use in BAV patients, TAVR demonstrates promising performance, but post-TAVR complications tend to get exacerbated due to BAV anatomical complexities. Utilizing patient-specific computational modeling, we address some of these complications. The degree and location of post-TAVR PVL was assessed, and the risk of flow-induced thrombogenicity was analyzed in 3 BAV patients - using older generation TAVR devices that were implanted in these patients, and compared them to the performance of the newest generation TAVR devices using in silico patient models. Significant decrease in PVL and thrombogenic potential was observed after implantation of the newest generation device. The current work demonstrates the potential of using simulations in pre-procedural planning to assess post-TAVR complications, and compare the performance of different devices to achieve better clinical outcomes. Patient-specific computational framework to assess post-transcatheter bicuspid aortic valve replacement paravalvular leakage and flow-induced thrombogenic complications and compare device performances.
Collapse
|
19
|
Heitkemper M, Sivakumar S, Hatoum H, Dollery J, Lilly SM, Dasi LP. Simple 2-dimensional anatomic model to predict the risk of coronary obstruction during transcatheter aortic valve replacement. J Thorac Cardiovasc Surg 2021; 162:1075-1083.e1. [PMID: 32222410 PMCID: PMC7434688 DOI: 10.1016/j.jtcvs.2020.01.085] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Revised: 01/17/2020] [Accepted: 01/21/2020] [Indexed: 12/30/2022]
Abstract
OBJECTIVE In this study, a 2-dimensional (2D) index relying on preprocedural computed tomography (CT) data was developed to evaluate the risk of coronary obstruction during transcatheter aortic valve replacement (TAVR) procedures. METHODS Anatomic measurements from pre-TAVR CT scans were collected in 28 patients among 600 who were flagged as high risk (defined as meeting coronary artery height, h, <14 mm and/or sinus of Valsalva diameter, SOVd, <30 mm) for coronary obstruction. A geometric model derived from these anatomic measurements was used to predict the post-TAVR native cusp apposition relative to the coronary ostium. The distance from the cusp to the coronary ostium, DLC2D, was measured from the geometric model and indexed with the coronary artery diameter, d, to yield a fractional obstruction measure, DLC2D/d. RESULTS Twenty-three of 28 high-risk patients successfully underwent TAVR without coronary obstruction, of whom 1 had coronary obstruction and 4 were deemed non-TAVR candidates. DLC2D/d differed significantly between the 2 groups (P < .0018), but neither h nor SOVd did (P > .32). The optimal sensitivity and specificity for DLC2D/d were 85% and occurred at a cutoff of 0.45. The optimal sensitivity and specificity of h and SOVd in this high-risk group were only 60% and 40%, respectively, for cutoffs of h = 10 mm and SOVd = 30.5 mm. CONCLUSIONS The 2D geometric model derived in this study shows promise for identifying patients with low-lying coronary ostium and/or small SOVd that may be safely treated with TAVR. DLC2D/d is more predictive of obstruction or poor TAVR candidacy compared with h and SOVd.
Collapse
Affiliation(s)
- Megan Heitkemper
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio
| | - Srikrishna Sivakumar
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga
| | - Hoda Hatoum
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga
| | - Jennifer Dollery
- Division of Cardiology, The Ohio State University, Columbus, Ohio
| | - Scott M Lilly
- Division of Cardiology, The Ohio State University, Columbus, Ohio
| | - Lakshmi Prasad Dasi
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga.
| |
Collapse
|
20
|
Bui HT, Khair N, Yeats B, Gooden S, James SP, Dasi LP. Transcatheter Heart Valves: A Biomaterials Perspective. Adv Healthc Mater 2021; 10:e2100115. [PMID: 34038627 DOI: 10.1002/adhm.202100115] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 04/23/2021] [Indexed: 11/11/2022]
Abstract
Heart valve disease is prevalent throughout the world, and the number of heart valve replacements is expected to increase rapidly in the coming years. Transcatheter heart valve replacement (THVR) provides a safe and minimally invasive means for heart valve replacement in high-risk patients. The latest clinical data demonstrates that THVR is a practical solution for low-risk patients. Despite these promising results, there is no long-term (>20 years) durability data on transcatheter heart valves (THVs), raising concerns about material degeneration and long-term performance. This review presents a detailed account of the materials development for THVRs. It provides a brief overview of THVR, the native valve properties, the criteria for an ideal THV, and how these devices are tested. A comprehensive review of materials and their applications in THVR, including how these materials are fabricated, prepared, and assembled into THVs is presented, followed by a discussion of current and future THVR biomaterial trends. The field of THVR is proliferating, and this review serves as a guide for understanding the development of THVs from a materials science and engineering perspective.
Collapse
Affiliation(s)
- Hieu T. Bui
- Department of Biomedical Engineering Georgia Institute of Technology 387 Technology Cir NW Atlanta GA 30313 USA
| | - Nipa Khair
- School of Advanced Materials Discovery Colorado State University 700 Meridian Ave Fort Collins CO 80523 USA
| | - Breandan Yeats
- Department of Biomedical Engineering Georgia Institute of Technology 387 Technology Cir NW Atlanta GA 30313 USA
| | - Shelley Gooden
- Department of Biomedical Engineering Georgia Institute of Technology 387 Technology Cir NW Atlanta GA 30313 USA
| | - Susan P. James
- School of Advanced Materials Discovery Colorado State University 700 Meridian Ave Fort Collins CO 80523 USA
| | - Lakshmi Prasad Dasi
- Department of Biomedical Engineering Georgia Institute of Technology 387 Technology Cir NW Atlanta GA 30313 USA
| |
Collapse
|
21
|
Loureiro-Ga M, Veiga C, Fdez-Manin G, Jimenez VA, Juan-Salvadores P, Busto L, Baz JA, Iñiguez A. Predicting TAVI paravalvular regurgitation outcomes based on numerical simulation of the aortic annulus eccentricity and perivalvular areas. Comput Methods Biomech Biomed Engin 2021; 24:1629-1637. [PMID: 33779444 DOI: 10.1080/10255842.2021.1906233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Trans-catheter aortic valve implantation (TAVI) is an increasingly adopted technique which provides a minimal invasive solution for patients who suffer from severe aortic stenosis. Some complications of the procedure could be annular rupture or paravalvular leakage, both related with adverse outcome. In TAVI with balloon expandable devices, a mismatch between those two factors leads to a conflict situation, where improving one worsens the other. The presented research proposes a methodology that uses numerical simulation to obtain certain TAVI outcomes related with aortic regurgitation due to paravalvular leakage, such as perivalvular area, aortic eccentricity or annular pressure. The application of the methodology for two patients shows the possibility of predicting those quantities. The highest stress values are distributed along the contact area. Results also show that a great deformation on the aortic annulus does not necessarily imply a higher stress; pressure can either be converted into root reshape or into root stretching. Validation of the results was done using scientific publications, clinical guidelines and clinical reports. Numerical simulation provides a suitable tool that could possibly contribute to optimize the planification procedure adjusting the mismatch between size and pressure.
Collapse
Affiliation(s)
- Marcos Loureiro-Ga
- Cardiology Research Group, Galicia Sur Health Research Institute (IIS Galicia Sur), SERGAS-UVIGO, Vigo, Spain.,Department of Applied Mathematics II, University of Vigo, Vigo, Spain
| | - Cesar Veiga
- Cardiology Research Group, Galicia Sur Health Research Institute (IIS Galicia Sur), SERGAS-UVIGO, Vigo, Spain
| | | | | | - Pablo Juan-Salvadores
- Cardiology Research Group, Galicia Sur Health Research Institute (IIS Galicia Sur), SERGAS-UVIGO, Vigo, Spain
| | - Laura Busto
- Cardiology Research Group, Galicia Sur Health Research Institute (IIS Galicia Sur), SERGAS-UVIGO, Vigo, Spain
| | - Jose Antonio Baz
- Cardiology Department, Complexo Hospitalario Universitario de Vigo (CHUVI), Vigo, Spain
| | - Andrés Iñiguez
- Cardiology Department, Complexo Hospitalario Universitario de Vigo (CHUVI), Vigo, Spain
| |
Collapse
|
22
|
Yaakobovich H, Plitman Mayo R, Zaretsky U, Finkelstein A, Weiss D, Marom G. The effect of clinically recommended Evolut sizes on anchorage forces after BASILICA. J Biomech 2021; 118:110303. [PMID: 33601185 DOI: 10.1016/j.jbiomech.2021.110303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Accepted: 01/16/2021] [Indexed: 11/28/2022]
Abstract
Coronary artery obstruction (CAO), a fatal complication of transcatheter aortic valve replacement (TAVR), is commonly found after Valve-in-Valve implantation inside a degenerated bioprosthetic valve. Leaflet laceration (BASILICA technique) has been proposed to prevent CAO and to potentially reduce the risk of leaflet thrombosis. We have previously demonstrated that this technique can reduce the anchorage forces of the TAVR device, which may lead to future complications. In this short communication, we hypothesize that the anchorage force reduction can be minimized by implanting a TAVR with a larger diameter, if two sizes are clinically recommended. We evaluated this hypothesis by employing finite element models of the deployments of the Evolut 26 and 29 mm inside a 27 mm Mitroflow valve, with and without leaflet lacerations. The results show that a laceration substantially decreases the contact area between the Evolut stent and the Mitroflow valve. The larger Evolut has a larger contact area and stronger anchorage forces. Additionally, the anchorage forces are less sensitive to additional lacerations in the larger Evolut (29 case). The results suggest that a larger self-expending device can ensure stronger anchorage and can lower the risk of possible migration, when TAVR is performed in a lacerated bioprosthesis.
Collapse
Affiliation(s)
- Halit Yaakobovich
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
| | | | - Uri Zaretsky
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
| | | | - Dar Weiss
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel; Department of Biomedical Engineering, Yale University, CT, USA
| | - Gil Marom
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel.
| |
Collapse
|
23
|
Azriff Basri A, Zuber M, Illyani Basri E, Shukri Zakaria M, Fazli Abd Aziz A, Tamagawa M, Arifin Ahmad K. Fluid-Structure Interaction in Problems of Patient Specific Transcatheter Aortic Valve Implantation with and Without Paravalvular Leakage Complication. FLUID DYNAMICS & MATERIALS PROCESSING 2021; 17:531-553. [DOI: 10.32604/fdmp.2021.010925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
24
|
Ghosh RP, Marom G, Bianchi M, D'souza K, Zietak W, Bluestein D. Numerical evaluation of transcatheter aortic valve performance during heart beating and its post-deployment fluid-structure interaction analysis. Biomech Model Mechanobiol 2020; 19:1725-1740. [PMID: 32095912 DOI: 10.1007/s10237-020-01304-9] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Accepted: 02/02/2020] [Indexed: 01/11/2023]
Abstract
Transcatheter aortic valve replacement (TAVR) is a minimally invasive procedure that provides an effective alternative to open-heart surgical valve replacement for treating advanced calcific aortic valve disease patients. However, complications, such as valve durability, device migration, paravalvular leakage (PVL), and thrombogenicity may lead to increased overall post-TAVR morbidity and mortality. A series of numerical studies involving a self-expandable TAVR valve were performed to evaluate these complications. Structural studies were performed with finite element (FE) analysis, followed by computational fluid dynamics (CFD) simulations, and fluid-structure interaction (FSI) analysis. The FE analysis was utilized to study the effect of TAVR valve implantation depth on valve anchorage in the Living Heart Human Model, which is capable of simulating beating heart during repeated cardiac cycles. The TAVR deployment cases where no valve migration was observed were then used to calculate the post-deployment thrombogenic potential via CFD simulations. FSI analysis followed to further assess the post-deployment TAVR hemodynamic performance for different implantation depths. The deployed valves PVL, geometric and effective orifice areas, and the leaflets structural and flow stress magnitudes were compared to determine the device optimal landing zone. The combined structural and hemodynamic analysis indicated that with the TAVR valve deployed at an aft ventricle position an optimal performance was achieved in the specific anatomy studied. Given the TAVR's rapid expansion to younger lower-risk patients, the comprehensive numerical methodology proposed here can potentially be used as a predictive tool for both procedural planning and valve design optimization to minimize the reported complications.
Collapse
Affiliation(s)
- Ram P Ghosh
- Department of Biomedical Engineering, Health Sciences Center T08-050, Stony Brook University, Stony Brook, NY, 11794-8084, USA
| | - Gil Marom
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Matteo Bianchi
- Department of Biomedical Engineering, Health Sciences Center T08-050, Stony Brook University, Stony Brook, NY, 11794-8084, USA
| | - Karl D'souza
- Dassault Systèmes SIMULIA Corp, Johnston, RI, 02919, USA
| | - Wojtek Zietak
- Capvidia NV, Research Park Haasrode, Technologielaan 3, 3001, Leuven, Belgium
| | - Danny Bluestein
- Department of Biomedical Engineering, Health Sciences Center T08-050, Stony Brook University, Stony Brook, NY, 11794-8084, USA.
| |
Collapse
|
25
|
Chen C, Xiong Y, Jiang W, Wang Y, Wang Z, Chen Y. Experimental and Numerical Simulation of Biodegradable Stents with Different Strut Geometries. Cardiovasc Eng Technol 2019; 11:36-46. [DOI: 10.1007/s13239-019-00433-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 10/09/2019] [Indexed: 10/25/2022]
|
26
|
Does clinical data quality affect fluid-structure interaction simulations of patient-specific stenotic aortic valve models? J Biomech 2019; 94:202-210. [DOI: 10.1016/j.jbiomech.2019.07.047] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Revised: 07/29/2019] [Accepted: 07/31/2019] [Indexed: 11/17/2022]
|
27
|
Luraghi G, Migliavacca F, García-González A, Chiastra C, Rossi A, Cao D, Stefanini G, Rodriguez Matas JF. On the Modeling of Patient-Specific Transcatheter Aortic Valve Replacement: A Fluid-Structure Interaction Approach. Cardiovasc Eng Technol 2019; 10:437-455. [PMID: 31309527 DOI: 10.1007/s13239-019-00427-0] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Accepted: 07/04/2019] [Indexed: 12/14/2022]
Abstract
PURPOSE Transcatheter aortic valve replacement (TAVR) is a minimally invasive treatment for high-risk patients with aortic diseases. Despite its increasing use, many influential factors are still to be understood and require continuous investigation. The best numerical approach capable of reproducing both the valves mechanics and the hemodynamics is the fluid-structure interaction (FSI) modeling. The aim of this work is the development of a patient-specific FSI methodology able to model the implantation phase as well as the valve working conditions during cardiac cycles. METHODS The patient-specific domain, which included the aortic root, native valve and calcifications, was reconstructed from CT images, while the CAD model of the device, metallic frame and pericardium, was drawn from literature data. Ventricular and aortic pressure waveforms, derived from the patient's data, were used as boundary conditions. The proposed method was applied to two real clinical cases, which presented different outcomes in terms of paravalvular leakage (PVL), the main complication after TAVR. RESULTS The results confirmed the clinical prognosis of mild and moderate PVL with coherent values of regurgitant volume and effective regurgitant orifice area. Moreover, the final release configuration of the device and the velocity field were compared with postoperative CT scans and Doppler traces showing a good qualitative and quantitative matching. CONCLUSION In conclusion, the development of realistic and accurate FSI patient-specific models can be used as a support for clinical decisions before the implantation.
Collapse
Affiliation(s)
- Giulia Luraghi
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Piazza L. da Vinci 32, 20133, Milan, Italy.
| | - Francesco Migliavacca
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Piazza L. da Vinci 32, 20133, Milan, Italy
| | - Alberto García-González
- Laboratori de Càlcul Numèric (LaCàN), E.T.S. de Ingenieros de Caminos, Canales y Puertos, Universitat Politècnica de Catalunya (UPC), Jordi Girona 1-3, 08034, Barcelona, Spain
| | - Claudio Chiastra
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Piazza L. da Vinci 32, 20133, Milan, Italy.,PoliToBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129, Turin, Italy
| | - Alexia Rossi
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Pieve Emanuele, MI, Italy
| | - Davide Cao
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Pieve Emanuele, MI, Italy
| | - Giulio Stefanini
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Pieve Emanuele, MI, Italy
| | - Jose Felix Rodriguez Matas
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Piazza L. da Vinci 32, 20133, Milan, Italy
| |
Collapse
|
28
|
Numerical models of valve-in-valve implantation: effect of intentional leaflet laceration on the anchorage. Biomech Model Mechanobiol 2019; 19:415-426. [DOI: 10.1007/s10237-019-01218-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Accepted: 08/22/2019] [Indexed: 11/26/2022]
|
29
|
Rocatello G, El Faquir N, de Backer O, Swaans MJ, Latib A, Vicentini L, Segers P, De Beule M, de Jaegere P, Mortier P. The Impact of Size and Position of a Mechanical Expandable Transcatheter Aortic Valve: Novel Insights Through Computational Modelling and Simulation. J Cardiovasc Transl Res 2019; 12:435-446. [PMID: 31444672 DOI: 10.1007/s12265-019-09877-2] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Accepted: 02/22/2019] [Indexed: 10/26/2022]
Abstract
Transcatheter aortic valve implantation has become an established procedure to treat severe aortic stenosis. Correct device sizing/positioning is crucial for optimal outcome. Lotus valve sizing is based upon multiple aortic root dimensions. Hence, it often occurs that two valve sizes can be selected. In this study, patient-specific computer simulation is adopted to evaluate the influence of Lotus size/position on paravalvular aortic regurgitation (AR) and conduction abnormalities, in patients with equivocal aortic root dimensions. First, simulation was performed in 62 patients to validate the model in terms of predicted AR and conduction abnormalities using postoperative echocardiographic, angiographic and ECG-based data. Then, two Lotus sizes were simulated at two positions in patients with equivocal aortic root dimensions. Large valve size and deep position were associated with higher contact pressure, while only large size, not position, significantly reduced the predicted AR. Despite general trends, simulations revealed that optimal device size/position is patient-specific.
Collapse
Affiliation(s)
| | - Nahid El Faquir
- Department of Cardiology, Erasmus MC, Rotterdam, The Netherlands
| | - Ole de Backer
- Department of Cardiology, Rigshospitalet University Hospital, Copenhagen, Denmark
| | - Martin J Swaans
- Department of Cardiology, St. Antonius Ziekenhuis, Nieuwegein, The Netherlands
| | - Azeem Latib
- Department of Cardiology, San Raffaele Scientific Institute, Milan, Italy
| | - Luca Vicentini
- Department of Cardiology, San Raffaele Scientific Institute, Milan, Italy
| | | | | | - Peter de Jaegere
- Department of Cardiology, Erasmus MC, Rotterdam, The Netherlands
| | - Peter Mortier
- FEops NV, Technologiepark 122, 9052, Ghent, Belgium.
| |
Collapse
|
30
|
Caballero A, Mao W, McKay R, Sun W. The impact of balloon-expandable transcatheter aortic valve replacement on concomitant mitral regurgitation: a comprehensive computational analysis. J R Soc Interface 2019; 16:20190355. [PMID: 31409236 DOI: 10.1098/rsif.2019.0355] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
The aortic and mitral valves function in a reciprocal interdependent fashion. However, the impact of transcatheter aortic valve replacement (TAVR) on the aortic-mitral continuity and severity of mitral regurgitation (MR) are poorly understood. In this study, a comprehensive engineering analysis was performed to investigate the impact of TAVR on MR severity and left heart dynamics in a retrospective patient case who harbours bicuspid aortic valve stenosis and concomitant functional MR. The TAVR procedure was computer simulated using a balloon-expandable valve, and the impact of three implantation heights on aortic-mitral coupling, MR severity and device performance were analysed. The accuracy and predictability of the computer modelling framework were validated with pre- and post-operative echo data. The highest deployment model resulted in higher stresses in the native leaflets, contact radial force and stent recoil, while the midway implantation model gave better haemodynamic performance and MR reduction in this patient case. Although the regurgitant volume decreased (less than 10%) for the three deployment configurations, no significant differences in MR severity improvement and mitral leaflet tethering were found. Acute improvement in MR was (i) due to the mechanical compression of the stent against the aortic-mitral curtain, (ii) due to an immediate drop in the ventricular pressure and transmitral pressure gradient. Albeit a single real clinical case, it is our hope that such detailed engineering computational analysis could shed light on the underlying biomechanical mechanisms of TAVR impact on MR.
Collapse
Affiliation(s)
- Andrés Caballero
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Wenbin Mao
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Raymond McKay
- Division of Cardiology, The Hartford Hospital, Hartford, CT, USA
| | - Wei Sun
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| |
Collapse
|
31
|
Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage. Med Biol Eng Comput 2019; 57:2129-2143. [PMID: 31372826 DOI: 10.1007/s11517-019-02012-y] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Accepted: 07/08/2019] [Indexed: 12/17/2022]
Abstract
Calcific aortic valve disease (CAVD) is characterized by stiffened aortic valve leaflets. Bicuspid aortic valve (BAV) is the most common congenital heart disease. Transcatheter aortic valve replacement (TAVR) is a treatment approach for CAVD where a stent with mounted bioprosthetic valve is deployed on the stenotic valve. Performing TAVR in calcified BAV patients may be associated with post-procedural complications due to the BAV asymmetrical structure. This study aims to develop refined computational models simulating the deployments of Evolut R and PRO TAVR devices in a representative calcified BAV. The paravalvular leakage (PVL) was also calculated by computational fluid dynamics simulations. Computed tomography scan of severely stenotic BAV patient was acquired. The 3D calcium deposits were generated and embedded inside a parametric model of the BAV. Deployments of the Evolut R and PRO inside the calcified BAV were simulated in five bioprosthesis leaflet orientations. The hypothesis of asymmetric and elliptic stent deployment was confirmed. Positioning the bioprosthesis commissures aligned with the native commissures yielded the lowest PVL (15.7 vs. 29.5 mL/beat). The Evolut PRO reduced the PVL in half compared with the Evolut R (15.7 vs. 28.7 mL/beat). The proposed biomechanical computational model could optimize future TAVR treatment in BAV patients. Graphical abstract.
Collapse
|
32
|
Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage. Biomech Model Mechanobiol 2018; 18:435-451. [PMID: 30460623 DOI: 10.1007/s10237-018-1094-8] [Citation(s) in RCA: 89] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2018] [Accepted: 11/01/2018] [Indexed: 10/27/2022]
Abstract
Transcatheter aortic valve replacement (TAVR) has emerged as an effective alternative to conventional surgical valve replacement in high-risk patients afflicted by severe aortic stenosis. Despite newer-generation devices enhancements, post-procedural complications such as paravalvular leakage (PVL) and related thromboembolic events have been hindering TAVR expansion into lower-risk patients. Computational methods can be used to build and simulate patient-specific deployment of transcatheter aortic valves (TAVs) and help predict the occurrence and degree of PVL. In this study finite element analysis and computational fluid dynamics were used to investigate the influence of procedural parameters on post-deployment hemodynamics on three retrospective clinical cases affected by PVL. Specifically, TAV implantation depth and balloon inflation volume effects on stent anchorage, degree of paravalvular regurgitation and thrombogenic potential were analyzed for cases in which Edwards SAPIEN and Medtronic CoreValve were employed. CFD results were in good agreement with corresponding echocardiography data measured in patients in terms of the PVL jets locations and overall PVL degree. Furthermore, parametric analyses demonstrated that positioning and balloon over-expansion may have a direct impact on the post-deployment TAVR performance, achieving as high as 47% in PVL volume reduction. While the model predicted very well clinical data, further validation on a larger cohort of patients is needed to verify the level of the model's predictions in various patient-specific conditions. This study demonstrated that rigorous and realistic patient-specific numerical models could potentially serve as a valuable tool to assist physicians in pre-operative TAVR planning and TAV selection to ultimately reduce the risk of clinical complications.
Collapse
|
33
|
Rotman OM, Bianchi M, Ghosh RP, Kovarovic B, Bluestein D. Principles of TAVR valve design, modelling, and testing. Expert Rev Med Devices 2018; 15:771-791. [PMID: 30318937 PMCID: PMC6417919 DOI: 10.1080/17434440.2018.1536427] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
INTRODUCTION Transcatheter aortic valve replacement (TAVR) has emerged as an effective minimally-invasive alternative to surgical valve replacement in medium- to high-risk, elderly patients with calcific aortic valve disease and severe aortic stenosis. The rapid growth of the TAVR devices market has led to a high variety of designs, each aiming to address persistent complications associated with TAVR valves that may hamper the anticipated expansion of TAVR utility. AREAS COVERED Here we outline the challenges and the technical demands that TAVR devices need to address for achieving the desired expansion, and review design aspects of selected, latest generation, TAVR valves of both clinically-used and investigational devices. We further review in detail some of the up-to-date modeling and testing approaches for TAVR, both computationally and experimentally, and additionally discuss those as complementary approaches to the ISO 5840-3 standard. A comprehensive survey of the prior and up-to-date literature was conducted to cover the most pertaining issues and challenges that TAVR technology faces. EXPERT COMMENTARY The expansion of TAVR over SAVR and to new indications seems more promising than ever. With new challenges to come, new TAV design approaches, and materials used, are expected to emerge, and novel testing/modeling methods to be developed.
Collapse
Affiliation(s)
- Oren M. Rotman
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| | - Matteo Bianchi
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| | - Ram P. Ghosh
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| | - Brandon Kovarovic
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| |
Collapse
|
34
|
Caimi A, Sturla F, Pluchinotta FR, Giugno L, Secchi F, Votta E, Carminati M, Redaelli A. Prediction of stenting related adverse events through patient-specific finite element modelling. J Biomech 2018; 79:135-146. [PMID: 30139536 DOI: 10.1016/j.jbiomech.2018.08.006] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Revised: 08/03/2018] [Accepted: 08/10/2018] [Indexed: 11/29/2022]
Abstract
Right ventricular outflow tract (RVOT) calcific obstruction is frequent after homograft conduit implantation to treat congenital heart disease. Stenting and percutaneous pulmonary valve implantation (PPVI) can relieve the obstruction and prolong the conduit lifespan, but require accurate pre-procedural evaluation to minimize the risk of coronary artery (CA) compression, stent fracture, conduit injury or arterial distortion. Herein, we test patient-specific finite element (FE) modeling as a tool to assess stenting feasibility and investigate clinically relevant risks associated to the percutaneous intervention. Three patients undergoing attempted PPVI due to calcific RVOT conduit failure were enrolled; the calcific RVOT, the aortic root and the proximal CA were segmented on CT scans for each patient. We numerically reproduced RVOT balloon angioplasty to test procedure feasibility and the subsequent RVOT pre-stenting expanding the stent through a balloon-in-balloon delivery system. Our FE framework predicted the occurrence of CA compression in the patient excluded from the real procedure. In the two patients undergoing RVOT stenting, numerical results were consistent with intraprocedural in-vivo fluoroscopic evidences. Furthermore, it quantified the stresses on the stent and on the relevant native structures, highlighting their marked dependence on the extent, shape and location of the calcific deposits. Stent deployment induced displacement and mechanical loading of the calcific deposits, also impacting on the adjacent anatomical structures. This novel workflow has the potential to tackle the analysis of complex RVOT clinical scenarios, pinpointing the procedure impact on the dysfunctional anatomy and elucidating potential periprocedural complications.
Collapse
Affiliation(s)
- Alessandro Caimi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.
| | - Francesco Sturla
- 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Francesca Romana Pluchinotta
- Department of Paediatric Cardiology and Adult Congenital Heart Disease, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Luca Giugno
- Department of Paediatric Cardiology and Adult Congenital Heart Disease, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Francesco Secchi
- Department of Radiology, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Emiliano Votta
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
| | - Mario Carminati
- Department of Paediatric Cardiology and Adult Congenital Heart Disease, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Alberto Redaelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
| |
Collapse
|
35
|
Rotman OM, Kovarovic B, Chiu WC, Bianchi M, Marom G, Slepian MJ, Bluestein D. Novel Polymeric Valve for Transcatheter Aortic Valve Replacement Applications: In Vitro Hemodynamic Study. Ann Biomed Eng 2018; 47:113-125. [PMID: 30194551 DOI: 10.1007/s10439-018-02119-7] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Accepted: 08/17/2018] [Indexed: 11/30/2022]
Abstract
Transcatheter aortic valve replacement (TAVR) is a minimally-invasive approach for treating severe aortic stenosis. All clinically-used TAVR valves to date utilize chemically-fixed xenograft as the leaflet material. Inherent limitation of the tissue (e.g., calcific degeneration) motivates the search for alternative leaflet material. Here we introduce a novel polymeric TAVR valve that was designed to address the limitations of tissue-valves. In this study, we experimentally evaluated the hemodynamic performance of the valve and compared its performance to clinically-used valves: a gold standard surgical tissue valve, and a TAVR valve. Our comparative testing protocols included: (i) baseline hydrodynamics (ISO:5840-3), (ii) complementary patient-specific hydrodynamics in a dedicated system, and (iii) thrombogenicity. The patient-specific testing system facilitated comparing TAVR valves performance under more realistic conditions. Baseline hydrodynamics results at CO 4-7 L/min showed superior effective orifice area (EOA) for the polymer valve, most-notably as compared to the reference TAVR valve. Regurgitation fraction was higher in the polymeric valve, but within the ISO minimum requirements. Thrombogenicity trends followed the EOA results with the polymeric valve being the least thrombogenic, and clinical TAVR being the most. Hemodynamic-wise, the results strongly indicate that our polymeric TAVR valve can outperform tissue valves.
Collapse
Affiliation(s)
- Oren M Rotman
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA
| | - Brandon Kovarovic
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA
| | - Wei-Che Chiu
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA
| | - Matteo Bianchi
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA
| | - Gil Marom
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA.,School of Mechanical Engineering, Tel Aviv University, 6997801, Tel Aviv, Israel
| | - Marvin J Slepian
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA.
| |
Collapse
|
36
|
Study on the Accuracy of Structural and FSI Heart Valves Simulations. Cardiovasc Eng Technol 2018; 9:723-738. [DOI: 10.1007/s13239-018-00373-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Accepted: 08/11/2018] [Indexed: 12/29/2022]
|
37
|
Computational Fluid Dynamics Assessment Associated with Transcatheter Heart Valve Prostheses: A Position Paper of the ISO Working Group. Cardiovasc Eng Technol 2018; 9:289-299. [PMID: 29675697 DOI: 10.1007/s13239-018-0349-y] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Accepted: 03/08/2018] [Indexed: 12/19/2022]
Abstract
The governing international standard for the development of prosthetic heart valves is International Organization for Standardization (ISO) 5840. This standard requires the assessment of the thrombus potential of transcatheter heart valve substitutes using an integrated thrombus evaluation. Besides experimental flow field assessment and ex vivo flow testing, computational fluid dynamics is a critical component of this integrated approach. This position paper is intended to provide and discuss best practices for the setup of a computational model, numerical solving, post-processing, data evaluation and reporting, as it relates to transcatheter heart valve substitutes. This paper is not intended to be a review of current computational technology; instead, it represents the position of the ISO working group consisting of experts from academia and industry with regards to considerations for computational fluid dynamic assessment of transcatheter heart valve substitutes.
Collapse
|
38
|
Rotman OM, Kovarovic B, Sadasivan C, Gruberg L, Lieber BB, Bluestein D. Realistic Vascular Replicator for TAVR Procedures. Cardiovasc Eng Technol 2018; 9:339-350. [PMID: 29654509 DOI: 10.1007/s13239-018-0356-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Accepted: 04/07/2018] [Indexed: 10/17/2022]
Abstract
Transcatheter aortic valve replacement (TAVR) is an over-the-wire procedure for treatment of severe aortic stenosis (AS). TAVR valves are conventionally tested using simplified left heart simulators (LHS). While those provide baseline performance reliably, their aortic root geometries are far from the anatomical in situ configuration, often overestimating the valves' performance. We report on a novel benchtop patient-specific arterial replicator designed for testing TAVR and training interventional cardiologists in the procedure. The Replicator is an accurate model of the human upper body vasculature for training physicians in percutaneous interventions. It comprises of fully-automated Windkessel mechanism to recreate physiological flow conditions. Calcified aortic valve models were fabricated and incorporated into the Replicator, then tested for performing TAVR procedure by an experienced cardiologist using the Inovare valve. EOA, pressures, and angiograms were monitored pre- and post-TAVR. A St. Jude mechanical valve was tested as a reference that is less affected by the AS anatomy. Results in the Replicator of both valves were compared to the performance in a commercial ISO-compliant LHS. The AS anatomy in the Replicator resulted in a significant decrease of the TAVR valve performance relative to the simplified LHS, with EOA and transvalvular pressures comparable to clinical data. Minor change was seen in the mechanical valve performance. The Replicator showed to be an effective platform for TAVR testing. Unlike a simplified geometric anatomy LHS, it conservatively provides clinically-relevant outcomes and complement it. The Replicator can be most valuable for testing new valves under challenging patient anatomies, physicians training, and procedural planning.
Collapse
Affiliation(s)
- Oren M Rotman
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA
| | - Brandon Kovarovic
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA
| | - Chander Sadasivan
- Department of Neurological Surgery, Stony Brook University, Stony Brook, NY, 11794, USA.,Vascular Simulations LLC, Stony Brook, NY, 11790, USA
| | | | - Baruch B Lieber
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA.,Department of Neurological Surgery, Stony Brook University, Stony Brook, NY, 11794, USA.,Vascular Simulations LLC, Stony Brook, NY, 11790, USA
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA.
| |
Collapse
|
39
|
Bosi GM, Capelli C, Cheang MH, Delahunty N, Mullen M, Taylor AM, Schievano S. Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations. J Biomech 2018; 71:236-244. [PMID: 29482928 PMCID: PMC5889787 DOI: 10.1016/j.jbiomech.2018.02.017] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Revised: 02/07/2018] [Accepted: 02/09/2018] [Indexed: 10/31/2022]
Abstract
Patient-specific computational models are an established tool to support device development and test under clinically relevant boundary conditions. Potentially, such models could be used to aid the clinical decision-making process for percutaneous valve selection; however, their adoption in clinical practice is still limited to individual cases. To be fully informative, they should include patient-specific data on both anatomy and mechanics of the implantation site. In this work, fourteen patient-specific computational models for transcatheter aortic valve replacement (TAVR) with balloon-expandable Sapien XT devices were retrospectively developed to tune the material parameters of the implantation site mechanical model for the average TAVR population. Pre-procedural computed tomography (CT) images were post-processed to create the 3D patient-specific anatomy of the implantation site. Balloon valvuloplasty and device deployment were simulated with finite element (FE) analysis. Valve leaflets and aortic root were modelled as linear elastic materials, while calcification as elastoplastic. Material properties were initially selected from literature; then, a statistical analysis was designed to investigate the effect of each implantation site material parameter on the implanted stent diameter and thus identify the combination of material parameters for TAVR patients. These numerical models were validated against clinical data. The comparison between stent diameters measured from post-procedural fluoroscopy images and final computational results showed a mean difference of 2.5 ± 3.9%. Moreover, the numerical model detected the presence of paravalvular leakage (PVL) in 79% of cases, as assessed by post-TAVR echocardiographic examination. The final aim was to increase accuracy and reliability of such computational tools for prospective clinical applications.
Collapse
Affiliation(s)
- Giorgia M Bosi
- Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science & Great Ormond Street Hospital for Children, London, UK; Cardiovascular Engineering Laboratory, UCL Mechanical Engineering, London, UK.
| | - Claudio Capelli
- Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science & Great Ormond Street Hospital for Children, London, UK
| | - Mun Hong Cheang
- Barts Health NHS Trust, University College London Hospital, London, UK
| | - Nicola Delahunty
- Barts Health NHS Trust, University College London Hospital, London, UK
| | - Michael Mullen
- Barts Health NHS Trust, University College London Hospital, London, UK
| | - Andrew M Taylor
- Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science & Great Ormond Street Hospital for Children, London, UK
| | - Silvia Schievano
- Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science & Great Ormond Street Hospital for Children, London, UK
| |
Collapse
|
40
|
Abstract
In this Editor's Review, articles published in 2016 are organized by category and briefly summarized. We aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ Replacement, Recovery, and Regeneration. As the official journal of The International Federation for Artificial Organs, The International Faculty for Artificial Organs, the International Society for Mechanical Circulatory Support, the International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level." Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. We were pleased to publish our second Virtual Issue in April 2016 on "Tissue Engineering in Bone" by Professor Tsuyoshi Takato. Our first was published in 2011 titled "Intra-Aortic Balloon Pumping" by Dr. Ashraf Khir. Other peer-reviewed Special Issues this year included contributions from the 11th International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion edited by Dr. Akif Ündar and selections from the 23rd Congress of the International Society for Rotary Blood Pumps edited by Dr. Bojan Biocina. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide meaningful suggestions to the author's work whether eventually accepted or rejected. Without these excellent and dedicated reviewers the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, John Wiley & Sons for their expert attention and support in the production and marketing of Artificial Organs. We look forward to reporting further advances in the coming years.
Collapse
|
41
|
Bluestein D. Utilizing Computational Fluid Dynamics in Cardiovascular Engineering and Medicine-What You Need to Know. Its Translation to the Clinic/Bedside. Artif Organs 2017; 41:117-121. [PMID: 28181302 DOI: 10.1111/aor.12914] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8181, USA
| |
Collapse
|