1
|
Wu Q, Xue R, Zhao Y, Ramsay K, Wang EY, Savoji H, Veres T, Cartmell SH, Radisic M. Automated fabrication of a scalable heart-on-a-chip device by 3D printing of thermoplastic elastomer nanocomposite and hot embossing. Bioact Mater 2024; 33:46-60. [PMID: 38024233 PMCID: PMC10654006 DOI: 10.1016/j.bioactmat.2023.10.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 10/11/2023] [Accepted: 10/18/2023] [Indexed: 12/01/2023] Open
Abstract
The successful translation of organ-on-a-chip devices requires the development of an automated workflow for device fabrication, which is challenged by the need for precise deposition of multiple classes of materials in micro-meter scaled configurations. Many current heart-on-a-chip devices are produced manually, requiring the expertise and dexterity of skilled operators. Here, we devised an automated and scalable fabrication method to engineer a Biowire II multiwell platform to generate human iPSC-derived cardiac tissues. This high-throughput heart-on-a-chip platform incorporated fluorescent nanocomposite microwires as force sensors, produced from quantum dots and thermoplastic elastomer, and 3D printed on top of a polystyrene tissue culture base patterned by hot embossing. An array of built-in carbon electrodes was embedded in a single step into the base, flanking the microwells on both sides. The facile and rapid 3D printing approach efficiently and seamlessly scaled up the Biowire II system from an 8-well chip to a 24-well and a 96-well format, resulting in an increase of platform fabrication efficiency by 17,5000-69,000% per well. The device's compatibility with long-term electrical stimulation in each well facilitated the targeted generation of mature human iPSC-derived cardiac tissues, evident through a positive force-frequency relationship, post-rest potentiation, and well-aligned sarcomeric apparatus. This system's ease of use and its capacity to gauge drug responses in matured cardiac tissue make it a powerful and reliable platform for rapid preclinical drug screening and development.
Collapse
Affiliation(s)
- Qinghua Wu
- Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, M5S 3G9, Canada
- Toronto General Research Institute, University Health Network, Toronto, Ontario, M5G 2C4, Canada
| | - Ruikang Xue
- Department of Materials, School of Natural Sciences, Faculty of Science and Engineering and The Henry Royce Institute, Royce Hub Building, The University of Manchester, Manchester, UK
| | - Yimu Zhao
- Toronto General Research Institute, University Health Network, Toronto, Ontario, M5G 2C4, Canada
| | - Kaitlyn Ramsay
- Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, M5S 3G9, Canada
| | - Erika Yan Wang
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Houman Savoji
- Institute of Biomedical Engineering and Department of Pharmacology and Physiology, University of Montreal, Montreal, Quebec, H3T 1J4, Canada
- Research Center, Centre Hospitalier Universitaire Sainte-Justine, Montreal, Quebec, H3T 1C5, Canada
- Montreal TransMedTech Institute, Montreal, Quebec, H3T 1J4, Canada
| | - Teodor Veres
- National Research Council of Canada, Boucherville, QC, J4B 6Y4, Canada
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, M5S 3G8, Canada
| | - Sarah H. Cartmell
- Department of Materials, School of Natural Sciences, Faculty of Science and Engineering and The Henry Royce Institute, Royce Hub Building, The University of Manchester, Manchester, UK
| | - Milica Radisic
- Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, M5S 3G9, Canada
- Toronto General Research Institute, University Health Network, Toronto, Ontario, M5G 2C4, Canada
- Department of Chemical Engineering and Applied Chemistry, University of Toronto, Toronto, Ontario, M5S 3E5, Canada
- Terrence Donnelly Centre for Cellular & Biomolecular Research, University of Toronto, Toronto, ON, M5S 3E1, Canada
| |
Collapse
|
2
|
Tian C, Wang Z, Huang L, Liu Y, Wu K, Li Z, Han B, Jiao D, Han X, Zhao Y. One-step fabrication of lidocaine/CalliSpheres ® composites for painless transcatheter arterial embolization. Lab Invest 2022; 20:463. [PMID: 36221084 PMCID: PMC9552470 DOI: 10.1186/s12967-022-03653-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Accepted: 09/17/2022] [Indexed: 11/10/2022]
Abstract
BACKGROUND Transcatheter arterial embolization (TAE) is one of the first-line treatments for advanced hepatocellular cancer. The pain caused by TAE is a stark complication, which remains to be prevented by biomedical engineering methods. METHODS Herein, a commercial embolic agent CalliSpheres® bead (CB) was functionally modified with lidocaine (Lid) using an electrostatic self-assembly technique. The products were coded as CB/Lid-n (n = 0, 5, 10, corresponding to the relative content of Lid). The chemical compositions, morphology, drug-loading, and drug-releasing ability of CB/Lid-n were comprehensively investigated. The biocompatibility was determined by hemolysis assay, live/dead cell staining assay, CCK8 assay, immunofluorescence (IHC) staining assay and quantitative real-time PCR. The thermal withdrawal latency (TWL) and edema ratio (ER) were performed to evaluate the analgesia of CB/Lid-n using a plantar inflammation model. A series of histological staining, including immunohistochemistry (IL-6, IL-10, TGF-β and Navi1.7) and TUNEL were conducted to reveal the underlying mechanism of anti-tumor effect of CB/Lid-n on a VX2-tumor bearing model. RESULTS Lid was successfully loaded onto the surface of CalliSpheres® bead, and the average diameter of CalliSpheres® bead increased along with the dosage of Lid. CB/Lid-n exhibited desirable drug-loading ratio, drug-embedding ratio, and sustained drug-release capability. CB/Lid-n had mild toxicity towards L929 cells, while triggered no obvious hemolysis. Furthermore, CB/Lid-n could improve the carrageenan-induced inflammation response micro-environment in vivo and in vitro. We found that CB/Lid-10 could selectively kill tumor by blocking blood supply, inhibiting cell proliferation, and promoting cell apoptosis. CB/Lid-10 could also release Lid to relieve post-operative pain, mainly by remodeling the harsh inflammation micro-environment (IME). CONCLUSIONS In summary, CB/Lid-10 has relatively good biocompatibility and bioactivity, and it can serve as a promising candidate for painless transcatheter arterial embolization.
Collapse
Affiliation(s)
- Chuan Tian
- Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China
| | - Zijian Wang
- Department of Urology, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China
| | - Lei Huang
- Department of Plastic Surgery, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China
| | - Yimin Liu
- Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China
| | - Kunpeng Wu
- Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China
| | - Zhaonan Li
- Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China
| | - Bin Han
- Department of Radiotherapy, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China
| | - Dechao Jiao
- Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China
| | - Xinwei Han
- Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China.
| | - Yanan Zhao
- Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China.
| |
Collapse
|