1
|
Yamashige D, Hijioka S, Nagashio Y, Maruki Y, Fukuda S, Yagi S, Okamoto K, Hara H, Hagiwara Y, Agarie D, Takasaki T, Chatto M, Ohba A, Kondo S, Morizane C, Ueno H, Sone M, Saito Y, Okusaka T. Incidence and factors associated with stent dysfunction and pancreatitis after gastroduodenal stenting for malignant gastric outlet obstruction. Endosc Int Open 2024; 12:E367-E376. [PMID: 38464977 PMCID: PMC10919994 DOI: 10.1055/a-2261-2833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2023] [Accepted: 12/13/2023] [Indexed: 03/12/2024] Open
Abstract
Background and study aims Endoscopic gastroduodenal stent (GDS) deployment is currently a standard treatment for malignant gastric outlet obstruction (mGOO) in patients with limited life expectancy; however, stent dysfunction (SD) and complicated pancreatitis often occur after GDS deployment. We investigated incidence and contributing factors of SD and complicated pancreatitis. Patients and methods We retrospectively reviewed 203 patients who underwent initial GDS deployment for palliation of mGOO symptoms between October 2017 and July 2022, including 109 who underwent GDS deployment across the duodenal papilla (sub-cohort). Results SDs, including tumor ingrowth (n = 26), kinking (n = 14), and migration (n = 13), occurred in 68 patients (33.5%). Cumulative SD incidence was 41.1% (95% confidence interval, 32.6-49.4%). SD incidence increased to 0.4%, 0.16%, and 0.06% per day at < 8, 8-16, and>16 weeks, respectively. On multivariate analysis, Niti-S pyloric/duodenal stent deployment (sub-distribution hazard ratio [sHR] 0.26, P = 0.01) and survival length ≥ 90 days (sHR 2.5, P = 0.01) were respectively identified as favorable and risk factors significantly associated with SD. Pancreatitis developed in 14 patients (12.8%) in the sub-cohort, which had significantly higher parenchymal diameter ( P < 0.01) and lower main pancreatic duct (MPD) caliber ( P < 0.01) than the non-pancreatitis cohort. On multivariate analysis, MPD caliber < 3 mm independently predicted pancreatitis (odds ratio 6.8, P = 0.03). Conclusions Deployment of the Niti-S pyloric/duodenal stent, with conformability even for angulated strictures, significantly reduced the incidence of SD. Stent selection, life expectancy, and MPD caliber should be taken into consideration during decision-making for GDS deployment for mGOO.
Collapse
Affiliation(s)
- Daiki Yamashige
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Susumu Hijioka
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Yoshikuni Nagashio
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Yuta Maruki
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Soma Fukuda
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Shin Yagi
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Kohei Okamoto
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Hidenobu Hara
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Yuya Hagiwara
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Daiki Agarie
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Tetsuro Takasaki
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Mark Chatto
- Department of Gastroenterology, Makati Medical Center, Makati City, Philippines
| | - Akihiro Ohba
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Shunsuke Kondo
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Chigusa Morizane
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Hideki Ueno
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| | - Miyuki Sone
- Department of Diagnostic Radiology, National Cancer Center Japan, Chuo-ku, Japan
| | - Yutaka Saito
- Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan
| | - Takuji Okusaka
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital Japan, Chuo-ku, Japan
| |
Collapse
|
2
|
Tokura J, Yoshio T, Hayashi S, Yamamoto M, Asai S, Yakushijin T, Ikezawa K, Nagaike K, Takagi T, Fujisawa T, Yamada T, Tsumura H, Maetani I, Hori Y, Ihara H, Matsunaga K, Kuwai T, Ito Y, Hasatani K, Komeda Y, Kurita A, Yamaguchi S, Maruyama H, Iwashita T, Takenaka M, Hosono M, Nishida T. Medical radiation exposure during gastrointestinal enteral metallic stent placement: Post hoc analysis of the REX-GI study. JGH Open 2023; 7:869-874. [PMID: 38162840 PMCID: PMC10757487 DOI: 10.1002/jgh3.12993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Accepted: 10/16/2023] [Indexed: 01/03/2024]
Abstract
BACKGROUND AND AIM Recently, the use of various endoscopic procedures performed under X-ray fluoroscopy guidance has increased. With the popularization of such procedures, diagnostic reference levels (DRLs) have been widely accepted as the global standard for various procedures with ionizing radiation. The Radiation Exposure from Gastrointestinal Fluoroscopic Procedures (REX-GI) study aimed to prospectively collect actual radiation exposure (RE) data and establish DRLs in gastrointestinal endoscopy units. In this post hoc analysis of the REX-GI study, we established DRLs for each disease site by analyzing cases of gastrointestinal enteral metallic stent placement. METHODS The REX-GI study was a multicenter, prospective observational study conducted to collect actual RE data during gastrointestinal enteral metallic stent placement. To establish DRL values for three disease sites, namely the esophagus, gastroduodenum, and colon, we examined fluoroscopy time (FT; min), number of X-ray images, air kerma at the patient entrance reference point (K a,r; mGy), and the air kerma-area product (P KA; Gy cm2) during enteral metallic stent placement. RESULTS Five-hundred and twenty-three stenting procedures were performed. The DRL values of FT (min) and the number of X-ray images for the esophagus/gastroduodenum/colon were 9/16/18 min and 9/15/11 min, respectively. Furthermore, the DRL values of K a,r and P KA for each disease site were 43.3/120/124 mGy and 10.3/36.6/48.4 Gy cm2, respectively. Among the procedures, esophageal stents were significantly associated with the lowest values (P < 0.001). CONCLUSION The characteristics of RE vary according to disease site among gastrointestinal enteral metallic stent placements. Thus, it is desirable to set DRL values based on the disease site.
Collapse
Affiliation(s)
- Junki Tokura
- Department of GastroenterologyCancer Institute Hospital, Japanese Foundation for Cancer ResearchTokyoJapan
| | - Toshiyuki Yoshio
- Department of GastroenterologyCancer Institute Hospital, Japanese Foundation for Cancer ResearchTokyoJapan
| | - Shiro Hayashi
- Department of Gastroenterology and Internal MedicineHayashi ClinicSuitaJapan
- Department of GastroenterologyToyonaka Municipal HospitalToyonakaJapan
| | - Masashi Yamamoto
- Department of GastroenterologyToyonaka Municipal HospitalToyonakaJapan
| | - Satoshi Asai
- Department of GastroenterologyTane General HospitalOsakaJapan
| | - Takayuki Yakushijin
- Department of Gastroenterology and HepatologyOsaka General Medical CenterOsakaJapan
| | - Kenji Ikezawa
- Department of Hepatobiliary and Pancreatic OncologyOsaka International Cancer InstituteOsakaJapan
| | - Koji Nagaike
- Department of Gastroenterology and HepatologySuita Municipal HospitalOsakaJapan
| | - Tadayuki Takagi
- Department of Gastroenterology, Fukushima Medical University School of MedicineFukushimaJapan
| | - Toshio Fujisawa
- Department of GastroenterologyGraduate School of Medicine, Juntendo UniversityTokyoJapan
| | - Takuya Yamada
- Department of Gastroenterology and HepatologyOsaka Rosai HospitalSakaiJapan
| | - Hidetaka Tsumura
- Department of Gastroenterological OncologyHyogo Cancer CenterAkashiJapan
| | - Iruru Maetani
- Division of Gastroenterology and Hepatology, Department of Internal MedicineToho University Ohashi Medical CenterTokyoJapan
| | - Yasuki Hori
- Department of Gastroenterology and MetabolismNagoya City University Graduate School of Medical SciencesNagoyaJapan
| | - Hideyuki Ihara
- Department of GastroenterologyTonan HospitalSapporoJapan
| | - Kazuhiro Matsunaga
- Department of GastroenterologyIshikawa Prefectural Central HospitalKanazawaJapan
| | - Toshio Kuwai
- Department of Gastroenterology, National Hospital OrganizationKure Medical Center and Chugoku Cancer CenterKureJapan
| | - Yukiko Ito
- Department of GastroenterologyJapanese Red Cross Medical CenterTokyoJapan
| | - Kenkei Hasatani
- Department of GastroenterologyFukui Prefectural HospitalFukuiJapan
| | - Yoriaki Komeda
- Department of Gastroenterology and Hepatology, Faculty of MedicineKindai UniversityŌsakasayamaJapan
| | - Akira Kurita
- Department of Gastroenterology and HepatologyDigestive Disease Center, Kitano Hospital, Tazuke Kofukai Medical Research InstituteOsakaJapan
| | - Shinjiro Yamaguchi
- Department of Gastroenterology and HepatologyKansai Rosai HospitalAmagasakiJapan
| | - Hirotsugu Maruyama
- Department of GastroenterologyOsaka City University Graduate School of MedicineOsakaJapan
| | - Takuji Iwashita
- First Department of Internal MedicineGifu University HospitalGifuJapan
| | - Mamoru Takenaka
- Department of Gastroenterology and Hepatology, Faculty of MedicineKindai UniversityŌsakasayamaJapan
| | - Makoto Hosono
- Department of Gastroenterology and Hepatology, Faculty of MedicineKindai UniversityŌsakasayamaJapan
| | - Tsutomu Nishida
- Department of GastroenterologyToyonaka Municipal HospitalToyonakaJapan
| |
Collapse
|
3
|
Maetani I. How to successfully administer palliative treatment with a stent for malignant gastric outlet obstruction? Front Med (Lausanne) 2022; 9:967740. [PMID: 36017000 PMCID: PMC9395687 DOI: 10.3389/fmed.2022.967740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 07/18/2022] [Indexed: 11/13/2022] Open
Abstract
Although endoscopic stenting (ES) has been widely used as a less-invasive palliation method for malignant gastric outlet obstruction (GOO), recent reports have highlighted issues related to the procedure. For successful treatment, various aspects must be assessed before considering the practices. First, it is necessary to eliminate cases with contraindications such as coexistence of distal small-bowel obstruction or perforation. Other factors potentially related to clinical failure (i.e., peritoneal carcinomatosis) may require consideration but remain controversial. ES has better short-term outcomes than surgical gastrojejunostomy (GJ). GJ has recently been considered preferable in cases with longer life expectancy because of superior sustainability. Various types of stents are now commercially available, but their ideal structure and mechanical properties have not yet been clarified. Covered metal stent may reduce stent obstruction but is prone to increase stent migration, and its significance remains uncertain. Subsequent chemotherapy after stenting should be considered, as it is expected to prolong patient survival without increasing the risk of adverse events. Furthermore, it may be helpful in preventing tumor ingrowth. In cases with GOO combined with biliary obstruction, biliary intervention is often difficult. Recently, endoscopic ultrasound-guided biliary drainage (EUS-BD) has been widely used as an alternative procedure for endoscopic transpapillary biliary drainage (ETBD). Despite the lack of consensus as to whether ETBD or EUS-BD is preferred, EUS-BD is useful as a salvage technique for cases where ETBD is difficult. To perform stent placement successfully, it is important to pay attention to the above points; however, many remaining issues need to be clarified in the future.
Collapse
|
4
|
Reijm AN, Zellenrath PA, van der Bogt RD, van Driel LMJW, Siersema PD, Bruno MJ, Spaander MCW. Self-expandable duodenal metal stent placement for the palliation of gastric outlet obstruction over the past 20 years. Endoscopy 2022; 54:1139-1146. [PMID: 35483885 PMCID: PMC9708383 DOI: 10.1055/a-1838-5642] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
INTRODUCTION Duodenal stent placement is a palliative option for management of malignant gastric outlet obstruction (GOO). In the last 20 years, management of gastrointestinal cancers has considerably changed. It is unknown if these changes have affected clinical outcome of duodenal stent placement. METHODS Retrospective cohort study conducted in a tertiary referral center. Patients who underwent duodenal stent placement for GOO-symptoms due to a malignant stricture were included. Primary outcome was GOO-symptom free survival. Secondary outcomes included stent-related adverse event rates. Potential explanatory parameters such as period of stent placement (1998-2009 vs 2010-2019), prior treatments, peritoneal deposits, and stricture length were evaluated using multivariable Cox regression analysis. RESULTS A total of 147 patients (62 % male; median age 64 years) were included. After a median of 28 days after stent placement, 82 patients (57 %) had recurrent GOO-symptoms. GOO-symptom free survival was significantly lower in 2010-2019 (P < 0.01). Time period was the only independent predictor for reduced GOO-symptom free survival (HR 1.76, P < 0.01). Stent-related adverse event rates increased over time (1998-2009: 31 % vs 2010-2019: 37 %). Prior treatment with chemotherapy and/or radiotherapy was significantly associated with an increased risk of adverse events (OR 2.53, P = 0.02). CONCLUSIONS Clinical outcome of duodenal stent placement did not improve over time. The decreased GOO-symptom free survival and increased adverse event rate in more recent years are probably related to the chemo- and/or radiotherapy treatment provided prior to duodenal stent placement.
Collapse
Affiliation(s)
- Agnes N. Reijm
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Pauline A. Zellenrath
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Ruben D. van der Bogt
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Lydi M. J. W. van Driel
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Peter D. Siersema
- Department of Gastroenterology and Hepatology, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Marco J. Bruno
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Manon C. W. Spaander
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
5
|
Krishnamoorthi R, Bomman S, Benias P, Kozarek RA, Peetermans JA, McMullen E, Gjata O, Irani SS. Efficacy and safety of endoscopic duodenal stent versus endoscopic or surgical gastrojejunostomy to treat malignant gastric outlet obstruction: systematic review and meta-analysis. Endosc Int Open 2022; 10:E874-E897. [PMID: 35692924 PMCID: PMC9187371 DOI: 10.1055/a-1794-0635] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 01/13/2022] [Indexed: 11/28/2022] Open
Abstract
Background and study aims Malignant disease accounts for up to 80 % of gastric outlet obstruction (GOO) cases, which may be treated with duodenal self-expanding metal stents (SEMS), surgical gastrojejunostomy (GJ), and more recently endoscopic-ultrasound-guided gastroenterostomy (EUS-GE). These three treatments have not been compared head-to-head in a randomized trial. Methods We searched the Embase and MEDLINE databases for studies published January 2015-February 2021 assessing treatment of malignant GOO using duodenal SEMS, endoscopic (EUS-GE) or surgical (laparoscopic or open) GJ. Efficacy outcomes assessed included technical and clinical success rates, GOO recurrence and reintervention. Safety outcomes included procedure-related bleeding or perforation, and stent-related events for the duodenal SEMS and EUS-GE arms. Results EUS-GE had a lower rate of technical success (95.3%) than duodenal SEMS (99.4 %) or surgical GJ (99.9%) ( P = 0.0048). For duodenal SEMS vs. EUS-GE vs. surgical GJ, rates of clinical success (88.9 % vs. 89.0 % vs. 92.3 % respectively, P = 0.49) were similar. EUS-GE had a lower rate of GOO recurrence based on limited data ( P = 0.0036), while duodenal SEMS had a higher rate of reintervention ( P = 0.041). Overall procedural complications were similar (duodenal SEMS 18.7 % vs. EUS-GE 21.9 % vs. surgical GJ 23.8 %, P = 0.32), but estimated bleeding rate was lowest ( P = 0.0048) and stent occlusion rate was highest ( P = 0.0002) for duodenal SEMS. Conclusions Duodenal SEMS, EUS-GE, and surgical GJ showed similar clinical efficacy for the treatment of malignant GOO. Duodenal SEMS had a lower procedure-related bleeding rate but higher rate of reintervention.
Collapse
Affiliation(s)
- Rajesh Krishnamoorthi
- Department of Gastroenterology and Hepatology, Virginia Mason Medical Center, Seattle, Washington, United States
| | - Shivanand Bomman
- Department of Gastroenterology and Hepatology, Virginia Mason Medical Center, Seattle, Washington, United States
| | - Petros Benias
- Division of Gastroenterology, Zucker School of Medicine at Hofstra/Northwell, North Shore University Hospital, Manhasset, New York, United States
| | - Richard A. Kozarek
- Department of Gastroenterology and Hepatology, Virginia Mason Medical Center, Seattle, Washington, United States
| | - Joyce A. Peetermans
- Endoscopy Division, Boston Scientific Corporation, Marlborough, Massachusetts, United States
| | - Edmund McMullen
- Endoscopy Division, Boston Scientific Corporation, Marlborough, Massachusetts, United States
| | - Ornela Gjata
- Endoscopy Division, Boston Scientific Corporation, Marlborough, Massachusetts, United States
| | - Shayan S. Irani
- Department of Gastroenterology and Hepatology, Virginia Mason Medical Center, Seattle, Washington, United States
| |
Collapse
|
6
|
Abstract
Malignant gastric outlet obstruction (MGOO) is a late complication of advanced malignancies, mostly occurring due to gastrointestinal cancers or external compression outside the lumen. It causes nausea, vomiting, poor appetite, weight loss, and decreased quality of life. In the past, surgical bypass was the gold standard for the management of MGOO. However, the introduction of self-expandable metallic stent (SEMS) provides several advantages over surgical bypass, including earlier oral intake, rapid symptom relief, less invasiveness, and shorter hospital stays; therefore, it has replaced surgical bypass as the mainstream management approach in most situations. Although SEMS placement is a safe and effective way for palliation of MGOO, stent dysfunction with obstruction or migration limits the utilization and increases repeated intervention. Endoscopic ultrasound-guided gastroenterostomy with lumen-apposing metal stent has emerged as an alternative way to bypass the obstruction site and restore the oral intake of patients. Although a lower stent dysfunction rate was reported, further prospective studies are warranted to validate its effectiveness and safety.
Collapse
Affiliation(s)
- Bing-Wei Ye
- Division of Gastroenterology, Department of Medicine, Taiwan Adventist Hospital, Taipei, Taiwan, ROC
- Division of Gastroenterology and Hepatology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
- Department of Medicine, National Yang Ming Chiao Tung University School of Medicine, Taipei, Taiwan, ROC
| | - Kuei-Chuan Lee
- Division of Gastroenterology and Hepatology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
- Department of Medicine, National Yang Ming Chiao Tung University School of Medicine, Taipei, Taiwan, ROC
| | - Ming-Chih Hou
- Division of Gastroenterology and Hepatology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
- Department of Medicine, National Yang Ming Chiao Tung University School of Medicine, Taipei, Taiwan, ROC
| |
Collapse
|
7
|
Patita M, Castro R, Libânio D, Bastos RP, Silva R, Dinis-Ribeiro M, Pimentel-Nunes P. Covered Metal Stent after Dysfunction of Uncovered Stents for Palliation of Gastrointestinal Malignant Obstruction. GE PORTUGUESE JOURNAL OF GASTROENTEROLOGY 2020; 27:383-390. [PMID: 33251287 PMCID: PMC7670366 DOI: 10.1159/000507200] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Accepted: 01/20/2020] [Indexed: 12/24/2022]
Abstract
BACKGROUND Self-expanding metal stents (SEMS) have been used for the palliative treatment of malignant gastrointestinal tract obstruction. However, restenosis or incomplete expansion of a first stent is a frequent complication, and the effectiveness of reintervention with placement of a second stent is still controversial. OBJECTIVE To evaluate the clinical outcomes of covered SEMS (cSEMS) placement after dysfunction of uncovered SEMS (uSEMS) by the stent-in-stent technique. PATIENTS AND METHODS We retrospectively studied a consecutive series of patients receiving palliative treatment for malignant gastrointestinal obstruction with cSEMS placement after uSEMS dysfunction in a tertiary center from January 2013 to August 2018. Technical and clinical success, time of patency, and adverse events were analyzed. RESULTS Twelve patients were included; their mean age was 60 ± 9 years. Eleven patients had gastric outlet obstruction, and 1 patient had compression of the transverse colon due to gastric neoplasia. In 5 cases, there was absence of early clinical success with uSEMS and stent dysfunction in 7 cases (median patency time: 81 days). There was 100% technical success and 91.7% clinical success after cSEMS placement. There were no adverse events nor need for reintervention. The median patency time after placement of both stents was 163 days (vs. 71 days with the initial stent). CONCLUSION cSEMS placement after uSEMS dysfunction is technically feasible and a clinically effective treatment for patients with recurrent malignant gastrointestinal obstruction, with good stent patency in the medium/long term. This approach seems to be safe and without increase in adverse effects.
Collapse
Affiliation(s)
- Marta Patita
- Gastroenterology Department, Hospital Garcia de Orta, Almada, Portugal
| | - Rui Castro
- Gastroenterology Department, Portuguese Oncology Institute of Porto, Porto, Portugal
| | - Diogo Libânio
- Gastroenterology Department, Portuguese Oncology Institute of Porto, Porto, Portugal
- Center for Research in Health Technologies and Information Systems, Porto, Portugal
| | - Rui Pedro Bastos
- Gastroenterology Department, Portuguese Oncology Institute of Porto, Porto, Portugal
| | - Rui Silva
- Gastroenterology Department, Portuguese Oncology Institute of Porto, Porto, Portugal
| | - Mário Dinis-Ribeiro
- Gastroenterology Department, Portuguese Oncology Institute of Porto, Porto, Portugal
- Center for Research in Health Technologies and Information Systems, Porto, Portugal
| | - Pedro Pimentel-Nunes
- Gastroenterology Department, Portuguese Oncology Institute of Porto, Porto, Portugal
- Center for Research in Health Technologies and Information Systems, Porto, Portugal
- Surgery and Physiology Department, Faculty of Medicine, University of Porto, Porto, Portugal
| |
Collapse
|
8
|
Miwa H, Sugimori K, Kaneko T, Ishii T, Iwase S, Irie K, Sanga K, Tozuka Y, Hirotani A, Komiyama S, Sato T, Tezuka S, Goda Y, Numata K, Maeda S. Clinical outcome of a highly flexible duodenal stent for gastric outlet obstruction: A multicenter prospective study. JGH Open 2020; 4:729-735. [PMID: 32782963 PMCID: PMC7411653 DOI: 10.1002/jgh3.12326] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Accepted: 03/05/2020] [Indexed: 12/17/2022]
Abstract
BACKGROUND AND AIM Endoscopic duodenal stenting for patients with malignant gastric outlet obstruction (GOO) has been widespread; however, clinical trials evaluating the structures of duodenal stents are lacking. Thus, we aimed to investigate the clinical outcomes of a highly flexible duodenal stent for GOO patients. METHODS A prospective study of duodenal stenting for GOO patients from five hospitals between August 2017 and August 2018 was performed. WallFlex Duodenal Soft were used in all procedures. The primary endpoint was clinical success, defined as an improvement in the GOO scoring system. RESULTS The study enrolled 31 patients (12 women, 19 men) with GOO, with a median age of 70 (range 52-90) years. Primary diseases were pancreatic cancer, gastric cancer, biliary tract cancer, and others in 14, 10, 3, and 4 patients, respectively. The technical success rate was 97%, and the clinical success rate was 87%. Simultaneous biliary drainage was performed in 19% of patients. Adverse events occurred in three patients. Chemotherapy was given in 41% of clinically successful cases, and the median overall survival time after stent placement was 82 days (range, 30-341 days), and. Stent dysfunction occurred in 30% of clinically successful cases (stent ingrowth in seven and stent overgrowth in one patient). The median time to stent dysfunction was 157 days (range, 11-183 days). Six patients were treated with additional stent placement after dysfunction. CONCLUSION Placement of a highly flexible duodenal stent is an effective and safe treatment for patients with GOO (UMIN-CTR 000028783).
Collapse
Affiliation(s)
- Haruo Miwa
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Kazuya Sugimori
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Takashi Kaneko
- Department of GastroenterologyYokohama Minami Kyousai HospitalYokohamaJapan
| | - Tomohiro Ishii
- Department of GastroenterologySaiseikai Yokohamashi Nanbu HospitalYokohamaJapan
| | - Shigeru Iwase
- Department of GastroenterologyFujisawa City HospitalFujisawaJapan
| | - Kuniyasu Irie
- Department of GastroenterologyYokohama City University Graduate School of MedicineYokohamaJapan
| | - Katsuyuki Sanga
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Yuichiro Tozuka
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Akane Hirotani
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Satoshi Komiyama
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Takeshi Sato
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Shun Tezuka
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Yoshihiro Goda
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Kazushi Numata
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Shin Maeda
- Department of GastroenterologyYokohama City University Graduate School of MedicineYokohamaJapan
| |
Collapse
|
9
|
Suder-Castro L, Ramírez-Solís M, Hernández-Guerrero A, de la Mora-Levy J, Alonso-Lárraga J, Hernández-Lara A. Predictors of self-expanding metallic stent dysfunction in malignant gastric outlet obstruction. REVISTA DE GASTROENTEROLOGÍA DE MÉXICO (ENGLISH EDITION) 2020. [DOI: 10.1016/j.rgmxen.2019.08.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
|
10
|
Miyasako Y, Kuwai T, Ishaq S, Tao K, Konishi H, Miura R, Sumida Y, Kuroki K, Tamaru Y, Kusunoki R, Yamaguchi A, Kouno H, Kohno H. Newly developed self-expandable Niti-S MD colonic metal stent for malignant colonic obstruction. World J Gastrointest Surg 2020; 12:138-148. [PMID: 32426093 PMCID: PMC7215972 DOI: 10.4240/wjgs.v12.i4.138] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2019] [Revised: 03/23/2020] [Accepted: 03/26/2020] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Colonic stents are increasingly used to treat acute malignant colonic obstructions. The WallFlex and Niti-S D type stents are the commonly used self-expandable metallic stents available in Japan since 2012. WallFlex stent has a risk of stent-related perforation because of its axial force, while the Niti-S D type stent has a risk of obstructive colitis because of its weaker radial force. Niti-S MD type stents not only overcome these limitations but also permit delivery through highly flexible-tipped smaller-caliber colonoscopes.
AIM To compare the efficacy and safety of the newly developed Niti-S MD type colonic stents.
METHODS This single-center retrospective observational study included 110 patients with endoscopic self-expandable metallic stents placed between November 2011 and December 2018: WallFlex (Group W, n = 37), Niti-S D type (Group N, n = 53), and Niti-S MD type (Group MD, n = 20). The primary outcome was clinical success, defined as a resolution of obstructive colonic symptoms, confirmed by clinical and radiological assessment within 48 h. The secondary outcome was technical success, defined as accurate stent placement with adequate stricture coverage on the first attempt without complications.
RESULTS The technical success rate was 100% in Groups W, N, and MD, and the overall clinical success rate was 89.2% (33/37), 96.2% (51/53), and 100% (20/20) in Groups W, N, and MD, respectively. Early adverse events included pain (3/37, 8.1%), poor expansion (1/37, 2.7%), and fever (1/37, 2.6%) in Group W and perforation due to obstructive colitis (2/53, 3.8%) in Group N (likely due to poor expansion). Late adverse events (after 7 d) included stent-related perforations (4/36, 11.1%) and stent occlusion (1/36, 2.8%) in Group W and stent occlusion (2/51, 3.9%) in Group N. The stent-related perforation rate in Group W was significantly higher than that in Group N (P < 0.05). No adverse event was observed in Group MD.
CONCLUSION In our early and limited experience, the newly developed Niti-S MD type colonic stent was effective and safe for treating acute malignant colonic obstruction.
Collapse
Affiliation(s)
- Yuki Miyasako
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Toshio Kuwai
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Sauid Ishaq
- Gastroenterology Department, Russells Hall Hospital, Birmingham City University, Birmingham B17 9BE, United Kingdom
- St George’s University, University Centre Grenada, West Indies, Grenada
| | - Kanae Tao
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Hirona Konishi
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Ryoichi Miura
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Yuki Sumida
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Kazutaka Kuroki
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Yuzuru Tamaru
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Ryusaku Kusunoki
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Atsushi Yamaguchi
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Hirotaka Kouno
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| | - Hiroshi Kohno
- Department of Gastroenterology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure 737-0023, Japan
| |
Collapse
|
11
|
Suder-Castro LS, Ramírez-Solís ME, Hernández-Guerrero AI, de la Mora-Levy JG, Alonso-Lárraga JO, Hernández-Lara AH. Predictors of self-expanding metallic stent dysfunction in malignant gastric outlet obstruction. REVISTA DE GASTROENTEROLOGÍA DE MÉXICO 2020; 85:275-281. [PMID: 32229056 DOI: 10.1016/j.rgmx.2019.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 04/16/2019] [Accepted: 08/08/2019] [Indexed: 11/19/2022]
Abstract
INTRODUCTION AND OBJECTIVES Self-expanding metallic stents (SEMS) are the ideal treatment for malignant gastric outlet obstruction (MGOO) in patients with a short life expectancy, but stent dysfunction is frequent. The primary aim of our study was to identify the predictive factors of SEMS dysfunction in MGOO and the secondary aim was to determine the technical success, clinical success, and nutritional impact after SEMS placement. MATERIAL AND METHODS A retrospective, longitudinal study was conducted at the gastrointestinal endoscopy department of the Instituto Nacional de Cancerología in Mexico City. Patients diagnosed with MGOO that underwent SEMS placement within the time frame of January 2015 to May 2018 were included. We utilized the gastric outlet obstruction scoring system (GOOSS) to determine clinical success and SEMS dysfunction. RESULTS The study included 43 patients, technical success was 97.7% (n=42), and clinical success was 88.3% (n=38). SEMS dysfunction presented in 30.2% (n=13) of the patients, occurring in<6 months after placement in 53.8% (n=7) of them. In the univariate analysis, the histologic subtype, diffuse gastric adenocarcinoma (p=0.02) and the use of uncovered SEMS (p=0.02) were the variables associated with dysfunction. Albumin levels and body mass index did not increase after SEMS placement. Medical follow-up was a mean 5.8 months (1-24 months). CONCLUSIONS SEMS demonstrated adequate technical and clinical efficacy in the treatment of MGOO. SEMS dysfunction was frequent and diffuse type gastric cancer and uncovered SEMS appeared to be dysfunction predictors.
Collapse
Affiliation(s)
- L S Suder-Castro
- Departamento de Endoscopia Gastrointestinal, Instituto Nacional de Cancerología, Ciudad de México, México.
| | - M E Ramírez-Solís
- Departamento de Endoscopia Gastrointestinal, Instituto Nacional de Cancerología, Ciudad de México, México
| | - A I Hernández-Guerrero
- Departamento de Endoscopia Gastrointestinal, Instituto Nacional de Cancerología, Ciudad de México, México
| | - J G de la Mora-Levy
- Departamento de Endoscopia Gastrointestinal, Instituto Nacional de Cancerología, Ciudad de México, México
| | - J O Alonso-Lárraga
- Departamento de Endoscopia Gastrointestinal, Instituto Nacional de Cancerología, Ciudad de México, México
| | - A H Hernández-Lara
- Departamento de Endoscopia Gastrointestinal, Instituto Nacional de Cancerología, Ciudad de México, México
| |
Collapse
|
12
|
Bekheet N, Kim MT, Park JH, Kim KY, Tsauo J, Zhe W, Lim YJ, Song HY. Fluoroscopic Gastroduodenal Stent Placement in 55 Patients with Endoscopic Stent Placement Failure. Cardiovasc Intervent Radiol 2018. [PMID: 29541839 DOI: 10.1007/s00270-018-1933-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
PURPOSE To evaluate the technical feasibility and clinical effectiveness of fluoroscopic self-expandable metal stent (SEMS) placement in malignant gastroduodenal obstructions after failed endoscopic SEMS placement. MATERIALS AND METHODS Between September 2010 and July 2017, 874 patients underwent endoscopic SEMS placement for dysphagia caused by malignant gastroduodenal obstructions. Endoscopic SEMS placement failed in 55 of 874 patients (6.3%). These patients were referred for fluoroscopic SEMS placement. In case of failed fluoroscopic SEMS placement, combined endoscopic and fluoroscopic SEMS placement was attempted at the same setting. RESULTS Fluoroscopic SEMS placement was technically successful in 40 of 55 patients (72.7%). Combined endoscopic and fluoroscopic SEMS placement was technically successful in 6 of 15 patients with fluoroscopic SEMS placement failure. Failures in the nine patients were due to complete obstruction (n = 5) and acute angulation at the stricture site (n = 4). The overall technical success rate was 83.6% (46/55). Clinical success was achieved in 95.6% of patients (44/46). Complications occurred in 7 of 46 patients (15.2%), including tumor overgrowth (n = 3), SEMS migration (n = 3), and bleeding (n = 1). The median SEMS patency and patient survival periods were 515 (95% confidence interval (CI), 266.6-761.5) and 83 (95% CI 60.6-105.4) days, respectively. CONCLUSIONS Fluoroscopic SEMS placement is technically feasible and clinically effective in cases of endoscopic SEMS placement failure. A combined endoscopic and fluoroscopic approach increases the technical success rate after failure of the endoscopic or fluoroscopic approach. LEVEL OF EVIDENCE Level IV.
Collapse
Affiliation(s)
- Nader Bekheet
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Republic of Korea.,Gastrointestinal Endoscopy and Liver Unit, Kasr Al-Ainy, Faculty of Medicine, Cairo University, Cairo, Egypt
| | - Min Tae Kim
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Republic of Korea.,Department of Radiologic Technology, Cheju Halla University, Jeju, Republic of Korea
| | - Jung-Hoon Park
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Republic of Korea.,Department of Biomedical Engineering Research Center, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Republic of Korea
| | - Kun Yung Kim
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Republic of Korea
| | - Jiaywei Tsauo
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Republic of Korea
| | - Wang Zhe
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Republic of Korea
| | - Young Je Lim
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Republic of Korea
| | - Ho-Young Song
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Republic of Korea.
| |
Collapse
|
13
|
Bulut E, Çiftçi T, Akhan O, Akıncı D. Palliation of malignant gastroduodenal obstruction: fluoroscopic metallic stent placement with different approaches. Diagn Interv Radiol 2018; 23:211-216. [PMID: 28209556 DOI: 10.5152/dir.2016.16165] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
PURPOSE We aimed to evaluate the safety and effectiveness of fluoroscopy-guided gastroduodenal metallic stent placement with different approaches in malignant obstruction. METHODS We retrospectively assessed 53 patients (33 men and 20 women; mean age, 58.7±15 years) who underwent stent placement between February 2004 and April 2014. All patients had unresectable tumors. The most common causes of obstruction were gastric (38%) and pancreatic cancers (36%). Uncovered self-expandable metallic stents (SEMS) were placed under fluoroscopic guidance. In addition to transoral approach in 46 patients (86.7%), transgastric and transhepatic approaches were used in six patients (11.3%) and one patient (1.8%), respectively. Gastric outlet obstruction scoring system (GOOSS) was used to evaluate oral intake before and after stenting. Patients were followed until death or the end of the study. RESULTS Technical and clinical success rates were 100% and 92%, respectively. The median stent patency was 76 days (range, 4-985 days). Mean preprocedural GOOSS score of 0.1 increased to postprocedural GOOSS score of 2.42 (P < 0.001). Afferent loop decompression was achieved in one symptomatic patient. Neither mortality nor major complications occurred due to stenting. Stent migration occurred in one patient (2%) and stent obstruction occurred in two patients (4%). Combined biliary and duodenal stenting were performed in 21 patients (40%). Post-stenting GOOSS scores were predictive of survival (P = 0.003). CONCLUSION Fluoroscopic metallic stent placement for palliation of malignant gastroduodenal obstruction is safe and effective with high technical and clinical success rates and minimal complications. High technical success rates can be achieved using different approaches.
Collapse
Affiliation(s)
- Elif Bulut
- Department of Radiology, Hacettepe University School of Medicine, Ankara, Turkey.
| | | | | | | |
Collapse
|
14
|
Ye BW, Chou CK, Hsieh YC, Li CP, Chao Y, Hou MC, Lin HC, Lee KC. Metallic Stent Expansion Rate at Day One Predicts Stent Patency in Patients with Gastric Outlet Obstruction. Dig Dis Sci 2017; 62:1286-1294. [PMID: 28315029 DOI: 10.1007/s10620-017-4534-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Accepted: 03/08/2017] [Indexed: 01/18/2023]
Abstract
BACKGROUND AND AIMS Self-expandable metallic stent insertion has been a mainstream treatment for relieving the obstructive symptoms of malignant gastric outlet obstruction (MGOO), a late-stage complication of gastrointestinal malignancies. This study aims to investigate the predictive value of stent expansion rates in clinical outcomes in patients with MGOO. METHODS Eighty-seven patients with inoperable MGOO receiving metallic stents were reviewed retrospectively from April 2010 to December 2014. Clinical outcomes, predictors of stent patency, and survival were analyzed. RESULTS The technical and clinical success rates were 100 and 94.3%, respectively. The median stent patency time was 114 days (range 13-570 days). The median survival time was 133 days (range 13-1145 days). Stent dysfunctions occurred in 28 patients (32.2%), with restenosis accounting for the majority (82%). The stent expansion rate ≥75% at Day 1 predicted the stent patency [hazard ratio (HR) 0.12, P = 0.04]. However, it did not correlate with survival. Non-gastric cancer origins (HR 2.41, P = 0.002) and peritoneal carcinomatosis (HR 2.54, P = 0.001) correlated with poor survival. However, post-stent chemotherapy (HR 0.55, P = 0.03) was related to better outcome. The comparison of clinical outcomes of first and second stent insertions showed no significant difference in the stent expansion rate either at Day 0 and Day 1 (P = 0.97 and P = 0.57). CONCLUSIONS Self-expandable metallic stent insertion is a safe and effective treatment for relieving the obstructive symptoms. The stent expansion rate ≥75% at Day 1 is a novel stent-related predictor of stent patency.
Collapse
Affiliation(s)
- Bing-Wei Ye
- Division of Gastroenterology and Hepatology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan.,Department of Medicine, National Yang-Ming University School of Medicine, Taipei, Taiwan.,Division of Gastroenterology, Department of Medicine, Taiwan Adventist Hospital, Taipei, Taiwan
| | - Chung-Kai Chou
- Department of Medicine, National Yang-Ming University School of Medicine, Taipei, Taiwan.,Division of Gastroenterology, Department of Medicine, National Yang-Ming University Hospital, Ilan, Taiwan
| | - Yun-Cheng Hsieh
- Division of Gastroenterology and Hepatology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan.,Department of Medicine, National Yang-Ming University School of Medicine, Taipei, Taiwan
| | - Chung-Pin Li
- Division of Gastroenterology and Hepatology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan.,Department of Medicine, National Yang-Ming University School of Medicine, Taipei, Taiwan
| | - Yee Chao
- Division of Gastroenterology and Hepatology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan.,Department of Medicine, National Yang-Ming University School of Medicine, Taipei, Taiwan
| | - Ming-Chih Hou
- Division of Gastroenterology and Hepatology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan.,Department of Medicine, National Yang-Ming University School of Medicine, Taipei, Taiwan.,Endoscopic Diagnosis and Therapeutic Center, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Han-Chieh Lin
- Division of Gastroenterology and Hepatology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan.,Department of Medicine, National Yang-Ming University School of Medicine, Taipei, Taiwan
| | - Kuei-Chuan Lee
- Division of Gastroenterology and Hepatology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan. .,Department of Medicine, National Yang-Ming University School of Medicine, Taipei, Taiwan.
| |
Collapse
|
15
|
Kato H, Tsutsumi K, Okada H. Recent advancements in stent therapy in patients with malignant gastroduodenal outlet obstruction. ANNALS OF TRANSLATIONAL MEDICINE 2017; 5:186. [PMID: 28616401 DOI: 10.21037/atm.2017.02.11] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Gastric outlet obstruction (GOO) is one of severe comorbidities caused by many kinds of malignant diseases and is associated with not only degradation of patients' quality of life but also mortality. Although surgical bypass is one of the main therapies for malignant GOO, it is often difficult to perform in end-stage patients. The deployment of self-expandable metallic stents (SEMSs) has recently become a viable alternative to surgical bypass for malignant GOO. This technique is less invasive and more effective, particularly in patients with poor prognoses. Many reports have referred to the feasibility, effectiveness, and safety of the placement of SEMSs for malignant GOO. According to these reports, the rates of technical and clinical success were reported to be relatively high and the rate of adverse events to be acceptable. However, precautions against severe adverse events such as massive bleeding and perforation are necessary. Several reports have described the differences in clinical results among different kinds of SEMSs. The presence of a covered design for SEMSs may affect the patency of SEMSs and the rate of stent dysfunction. Selection of the SEMS according to axial force may affect successful achievement of long patency of SEMSs and avoidance of gastroduodenal perforation at the bending site of the duodenum. Compared with high technical success rates nearing 100%, clinical success rates were usually lower than technical success. Therefore, determination of predictive factors for failure of clinical success is important. Several papers reported that low performance status could be associated with failure of clinical success. However, the association of clinical success with other factors such as carcinomatosa and ascites remains controversial, which is a problem to be solved. Reintervention with SEMS using the stent-in-stent method after stent dysfunction can be performed effectively as well as placement of the first SEMS.
Collapse
Affiliation(s)
- Hironari Kato
- Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
| | - Koichiro Tsutsumi
- Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
| | - Hiroyuki Okada
- Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
| |
Collapse
|
16
|
Hori Y, Naitoh I, Hayashi K, Ban T, Natsume M, Okumura F, Nakazawa T, Takada H, Hirano A, Jinno N, Togawa S, Ando T, Kataoka H, Joh T. Predictors of outcomes in patients undergoing covered and uncovered self-expandable metal stent placement for malignant gastric outlet obstruction: a multicenter study. Gastrointest Endosc 2017; 85:340-348.e1. [PMID: 27475489 DOI: 10.1016/j.gie.2016.07.048] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2016] [Accepted: 07/01/2016] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIMS Uncovered self-expandable metal stents (U-SEMSs) and covered self-expandable metal stents (C-SEMSs) are available for palliative therapy for malignant gastric outlet obstruction (GOO). However, clinical differences and indications between the 2 types of SEMSs have not been elucidated. METHODS We retrospectively compared 126 patients with U-SEMS and 126 patients with C-SEMSs with regard to clinical outcome and factors predictive of clinical improvement after SEMSs placement. RESULTS No significant difference was observed between the U-SEMS and C-SEMS groups with respect to technical success, clinical success, GOO score, or time to stent dysfunction. Stent migration was significantly more frequent in patients with C-SEMSs (U-SEMSs, .79%; C-SEMSs, 8.73%; P = .005). Karnofsky performance status, chemotherapy, peritoneal dissemination, and stent expansion ≤ 30% were associated significantly with poor GOO score improvement in multivariable analyses, but stent type was not (P = .213). In subgroup analyses, insufficient (≤30%) stent expansion was an independent factor in patients with U-SEMSs (P = .041) but not C-SEMSs. In the insufficient stent expansion subgroup, C-SEMSs was associated significantly with superior clinical improvement compared with U-SEMSs (P = .01). Insufficient stent expansion was observed more frequently in patients with GI obstruction because of anastomotic sites or metastatic cancer (44.8% [13/29], P = .001). CONCLUSIONS No clinical difference, apart from stent migration, was observed between patients with U-SEMSs and C-SEMSs. GI obstruction because of an anastomotic site or metastatic cancer may be an indication for C-SEMS use to improve oral intake after SEMSs placement.
Collapse
Affiliation(s)
- Yasuki Hori
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Itaru Naitoh
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Kazuki Hayashi
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Tesshin Ban
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Makoto Natsume
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan; Department of Gastroenterology, Midori Municipal Hospital, Nagoya, Japan
| | - Fumihiro Okumura
- Department of Gastroenterology, Gifu Prefectural Tajimi Hospital, Tajimi, Japan
| | - Takahiro Nakazawa
- Department of Gastroenterology, Nagoya Daini Red Cross Hospital, Nagoya, Japan
| | - Hiroki Takada
- Department of Gastroenterology, Kasugai Municipal Hospital, Kasugai, Japan
| | - Atsuyuki Hirano
- Department of Gastroenterology, Nagoya City West Medical Center, Nagoya, Japan
| | - Naruomi Jinno
- Department of Gastroenterology, Toyokawa City Hospital, Toyokawa, Japan
| | - Shozo Togawa
- Department of Gastroenterology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Japan
| | - Tomoaki Ando
- Department of Gastroenterology, Gamagori City Hospital, Gamagori, Japan
| | - Hiromi Kataoka
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Takashi Joh
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| |
Collapse
|
17
|
Yamao K, Kitano M, Kayahara T, Ishida E, Yamamoto H, Minaga K, Yamashita Y, Nakajima J, Asada M, Okabe Y, Osaki Y, Chiba Y, Imai H, Kudo M. Factors predicting through-the-scope gastroduodenal stenting outcomes in patients with gastric outlet obstruction: a large multicenter retrospective study in West Japan. Gastrointest Endosc 2016; 84:757-763.e6. [PMID: 27055762 DOI: 10.1016/j.gie.2016.03.1498] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Accepted: 03/26/2016] [Indexed: 02/07/2023]
Abstract
BACKGROUND AND AIMS Endoscopic gastroduodenal stenting for malignant gastric outlet obstruction recently has become more effective, but the factors that predict gastroduodenal stenting outcomes are poorly defined. This multicenter retrospective cohort study evaluated the clinical outcomes of gastroduodenal stenting in malignant gastroduodenal obstruction and identified factors predicting clinical ineffectiveness, stent dysfunction, and adverse events. METHODS All consecutive patients with malignant gastroduodenal obstruction who underwent through-the-scope gastroduodenal stenting from 2009 to 2014 at 4 tertiary-care medical centers were identified. Clinically ineffective stenting was defined as symptom recurrence and a gastric outlet obstruction scoring system (GOOSS) score <2. RESULTS Of the 278 patients (mean age ± standard deviation [SD] 71.7 ± 11.4 years), 121 (43.5%) and 87 (31.3%) had pancreatic and gastric cancer, respectively. Technical success was achieved in 277 patients (99.6%). GOOSS scores rose from 0.5 ± 0.6 to 2.6 ± 0.8. Stenting was ineffective in 32 patients (12.6%). Stent dysfunction that caused symptom recurrence during follow-up developed in 46 patients (16.6%). Adverse events occurred in 49 patients (17.7%). Three or more stenosis sites (odds ratio [OR] = 6.11; P < .01) and Karnofsky performance scores ≤50 (OR = 6.63; P < .01) predicted clinical ineffectiveness. Karnofsky performance scores ≤50 predicted stent dysfunction (hazard ratio [HR] = 3.63; P < .01). Bile duct stenosis (HR = 9.55; P = .02) and liver metastasis (HR = 9.42; P < .01) predicted stent overgrowth. Covered stent predicted stent migration (HR = 12.63; P < .01). Deployment of 2 stents predicted perforation (HR = 854.88; P < .01). CONCLUSIONS Through-the-scope gastroduodenal stenting tended to be ineffective in patients with poor performance status and long stenosis sites. Stent dysfunction occurred more frequently in patients with poorer performance status. Deployment of 2 stents was a risk factor for perforation. Identification of these risk variables may help yield better gastroduodenal stenting outcomes.
Collapse
Affiliation(s)
- Kentaro Yamao
- Department of Gastroenterology and Hepatology, Kinki University School of Medicine, Osaka-sayama, Japan
| | - Masayuki Kitano
- Department of Gastroenterology and Hepatology, Kinki University School of Medicine, Osaka-sayama, Japan
| | - Takahisa Kayahara
- Department of Gastroenterology and Hepatology, Kurashiki Central Hospital, Okayama, Japan
| | - Etsuji Ishida
- Department of Gastroenterology and Hepatology, Kurashiki Central Hospital, Okayama, Japan
| | - Hiroshi Yamamoto
- Department of Gastroenterology and Hepatology, Kurashiki Central Hospital, Okayama, Japan
| | - Kosuke Minaga
- Department of Gastroenterology, Japanese Red Cross Wakayama Medical Center, Wakayama, Japan
| | - Yukitaka Yamashita
- Department of Gastroenterology, Japanese Red Cross Wakayama Medical Center, Wakayama, Japan
| | - Jun Nakajima
- Department of Gastroenterology and Hepatology, Osaka Red Cross Hospital, Osaka, Japan
| | - Masanori Asada
- Department of Gastroenterology and Hepatology, Osaka Red Cross Hospital, Osaka, Japan
| | - Yoshihiro Okabe
- Department of Gastroenterology and Hepatology, Osaka Red Cross Hospital, Osaka, Japan
| | - Yukio Osaki
- Department of Gastroenterology and Hepatology, Osaka Red Cross Hospital, Osaka, Japan
| | - Yasutaka Chiba
- Clinical Research Center, Kinki University Hospital, Osaka-sayama, Japan
| | - Hajime Imai
- Department of Gastroenterology and Hepatology, Kinki University School of Medicine, Osaka-sayama, Japan
| | - Masatoshi Kudo
- Department of Gastroenterology and Hepatology, Kinki University School of Medicine, Osaka-sayama, Japan
| |
Collapse
|
18
|
Kato H, Kawamoto H, Matsumoto K, Moriyama I, Kamada H, Tsutsumi K, Goto D, Fukuba N, Kato K, Sonoyama H, Isomoto H, Okada H. Outcome of self-expandable metallic stent deployment in patients with malignant gastroduodenal outlet obstruction and Niti-S and WallFlex comparison: a multicenter retrospective clinical study. J Dig Dis 2016; 17:518-525. [PMID: 27383654 DOI: 10.1111/1751-2980.12377] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Revised: 06/20/2016] [Accepted: 06/30/2016] [Indexed: 12/11/2022]
Abstract
OBJECTIVES Several studies report on the outcomes of self-expandable metallic stents (SEMSs) deployment for malignant gastric outlet obstruction (GOO). However, data was mostly based on the analysis of single-center studies including only a small number of patients. This study aimed to evaluate clinical outcomes after the deployment of SEMS in patients with malignant GOO and to compare the clinical outcomes of two metallic stents with different designs. METHODS Altogether 125 consecutive patients from five institutions were included. Clinical outcomes were evaluated according to technical success, clinical success, stent patency period, survival period and complications. A comparison of clinical outcomes between Niti-S pyloric/duodenal and WallFlex duodenal stents was also undertaken. RESULTS Rates for clinical and technical success were 100% and 92.0%, respectively. The median stent patency and survival periods were 72.0 days (range 3-775 days) and 75.0 days (range 3-775 days), respectively. The rate of overall adverse events was 28.8%. The rate of stent dysfunction was 16.8%, and that of adverse events, except stent dysfunction was 12.0%. Massive bleeding occurred in two patients as a late complication. The clinical success rate for Niti-S stent was significantly higher than that for WallFlex stent (96.2% vs 84.8%, P = 0.023). CONCLUSIONS We successfully deployed a SEMS in malignant GOO. The selection of a SEMS with a lower axial force may be important for patients to resume the oral food intake. Additionally, consideration must be given to the appropriate management of fatal bleeding as a late complication.
Collapse
Affiliation(s)
- Hironari Kato
- Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan. .,Hakushusanbi Endoscopic Workshop Group, Japan.
| | - Hirofumi Kawamoto
- Department of General Internal Medicine 2, Kawasaki Medical School, Okayama, Japan.,Hakushusanbi Endoscopic Workshop Group, Japan
| | - Kazuya Matsumoto
- Department of Gastroenterology, Tottori University Hospital, Yonago, Japan.,Hakushusanbi Endoscopic Workshop Group, Japan
| | - Ichiro Moriyama
- Division of Clinical study of Oncology, Shimane University School of Medicine, Izumo, Japan.,Hakushusanbi Endoscopic Workshop Group, Japan
| | - Hideki Kamada
- Department of Gastroenterology and Neurology, Kagawa University, Kagawa, Japan.,Hakushusanbi Endoscopic Workshop Group, Japan
| | - Koichiro Tsutsumi
- Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
| | - Daisuke Goto
- Department of Gastroenterology and Hepatology, Tottori Municipal Hospital, Tottori, Japan
| | - Nobuhiko Fukuba
- Department of Internal Medicine II, Shimane University School of Medicine, Izumo, Japan
| | - Kiyohito Kato
- Department of Gastroenterology and Neurology, Kagawa University, Kagawa, Japan
| | - Hiroki Sonoyama
- Department of Internal Medicine II, Shimane University School of Medicine, Izumo, Japan
| | - Hajime Isomoto
- Department of Gastroenterology, Tottori University Hospital, Yonago, Japan
| | - Hiroyuki Okada
- Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
| |
Collapse
|
19
|
Okuwaki K, Kida M, Yamauchi H, Imaizumi H, Miyawaza S, Iwai T, Masutani H, Matsumoto T, Hasegawa R, Koizumi W. Randomized controlled exploratory study comparing the usefulness of two types of metallic stents with different axial forces for the management of duodenal obstruction caused by pancreatobiliary cancer. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES 2016; 23:289-97. [PMID: 26946214 DOI: 10.1002/jhbp.341] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Accepted: 03/01/2016] [Indexed: 12/25/2022]
Abstract
BACKGROUND Very few studies have examined effectiveness of duodenal stent placement (DSP) for duodenal obstruction (DO) caused specifically by pancreatobiliary cancer. We compared two types of stents with different axial forces (AF) for DO with pancreatobiliary cancer. METHODS The patients were randomly assigned to two stent groups with different AF (high AF stent, WallFlex™: W-group or low AF stent, Niti-S™: N-group). The primary endpoint was improvement in the Gastric Outlet Obstruction Scoring System (GOOSS) score. This study was registered at UMIN000009061. RESULTS The GOOSS scores significantly improved in both W-group (0.9 before vs. 2.7 after; P = 0.002) and N-group (1.0 before vs. 2.5 after; P = 0.001). The change in the GOOSS score after DSP did not differ significantly between the groups (P = 0.482). The median time to recurrent DO (RDO) was significantly shorter in W-group than in N-group (89 days vs. 421 days; P = 0.025). The incidence of RDO was significantly higher in W-group than in N-group (64% vs. 24%; P = 0.027). Stent kinking occurred only in W-group. CONCLUSIONS The GOOSS scores significantly improved after DSP, but effectiveness did not differ significantly between groups. The use of stents with high AF was related to short-term stent patency, but did not influence survival time.
Collapse
Affiliation(s)
- Kosuke Okuwaki
- Department of Gastroenterology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa 252-0374, Japan.
| | - Mitsuhiro Kida
- Department of Gastroenterology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa 252-0374, Japan
| | - Hiroshi Yamauchi
- Department of Gastroenterology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa 252-0374, Japan
| | - Hiroshi Imaizumi
- Department of Gastroenterology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa 252-0374, Japan
| | - Shiro Miyawaza
- Department of Gastroenterology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa 252-0374, Japan
| | - Tomohisa Iwai
- Department of Gastroenterology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa 252-0374, Japan
| | - Hironori Masutani
- Department of Gastroenterology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa 252-0374, Japan
| | - Takaaki Matsumoto
- Department of Gastroenterology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa 252-0374, Japan
| | - Rikiya Hasegawa
- Department of Gastroenterology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa 252-0374, Japan
| | - Wasaburo Koizumi
- Department of Gastroenterology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa 252-0374, Japan
| |
Collapse
|
20
|
Sato T, Hara K, Mizuno N, Hijioka S, Imaoka H, Yogi T, Tsutsumi H, Fujiyoshi T, Niwa Y, Tajika M, Tanaka T, Ishihara M, Kubota K, Nakajima A, Yamao K. Type of Combined Endoscopic Biliary and Gastroduodenal Stenting Is Significant for Biliary Route Maintenance. Intern Med 2016; 55:2153-61. [PMID: 27522990 DOI: 10.2169/internalmedicine.55.6410] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Objective Some patients with malignant gastric outlet obstruction require combined biliary and gastroduodenal stenting (double stenting). However, biliary stent dysfunction can often disturb biliary route maintenance, thus making the optimal biliary stenting for these patients unclear. The present study was designed to assess the factors associated with the long-term maintenance of biliary drainage routes. Methods The clinical features and long-term outcomes were assessed in patients who underwent double stenting. Patients The outcomes were reviewed in 43 consecutive patients who successfully underwent endoscopic double stenting with metallic stents. Results An univariate analysis of all patients with biliary stent dysfunction showed the separate type of double stenting (two stents placed in a non-crossed position) to be the only predictive factor related to successful biliary re-intervention for stent dysfunction (odds ratio 73.67, p=0.001). A comparison of the clinical features in patients who underwent separate and cross (two stents placed in a crossed position) stenting showed the functional success rate to be higher for the separate (93.3%) than for the cross (61.5%) stent type, with the median times to biliary stent dysfunction differing significantly (330 vs. 298 days, respectively; p=0.048). The success rates of re-intervention in patients with separate and cross type stents were 88.9% and 0.0%, respectively (p=0.001), and the initial biliary route maintenance rates were 96.7% and 53.8%, respectively (p=0.002). Conclusion The separate type of double stenting may enhance successful biliary re-intervention for stent dysfunction and also maintain the initial drainage route longer. The biliary drainage outcomes should therefore be considered when choosing the type of double stenting.
Collapse
Affiliation(s)
- Takamitsu Sato
- Department of Gastroenterology, Aichi Cancer Center Hospital, Japan
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Lee H, Min BH, Lee JH, Shin CM, Kim Y, Chung H, Lee SH. Covered metallic stents with an anti-migration design vs. uncovered stents for the palliation of malignant gastric outlet obstruction: a multicenter, randomized trial. Am J Gastroenterol 2015; 110:1440-9. [PMID: 26372507 PMCID: PMC4697131 DOI: 10.1038/ajg.2015.286] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2015] [Revised: 06/01/2015] [Accepted: 06/03/2015] [Indexed: 12/11/2022]
Abstract
OBJECTIVES Previous studies reported comparable stent patency between covered self-expandable metallic stents (SEMS) and uncovered SEMS (UCS) for palliation of malignant gastric outlet obstruction (GOO). The aim of this study was to evaluate the efficacy and safety of the newly developed WAVE-covered SEMS (WCS), which has an anti-migration design, compared with UCS in gastric cancer patients with symptomatic GOO. METHODS A total of 102 inoperable gastric cancer patients with symptomatic GOO were prospectively enrolled from five referral centers and randomized to undergo UCS or WCS placement. Stent patency and recurrence of obstructive symptoms were assessed at 8 weeks and 16 weeks after stent placement. RESULTS At the 8-week follow-up, both stent patency rates (72.5% vs. 62.7%) and re-intervention rates (19.6% vs. 19.6%) were comparable between the WCS and the UCS groups. Both stent stenosis (2.4% vs. 8.1%) and migration rates (9.5% vs. 5.4%) were comparable between WCS and UCS groups. At the 16-week follow-up, however, the WCS group had a significantly higher stent patency rate than the UCS group (68.6% vs. 41.2%). Re-intervention rates in the WCS and UCS groups were 23.5% and 39.2%, respectively. Compared with the UCS group, the WCS group had a significantly lower stent restenosis rate (7.1% vs. 37.8%) and a comparable migration rate (9.5% vs. 5.4%). Overall stent patency was significantly longer in the WCS group than in the UCS group. No stent-associated significant adverse events occurred in either the WCS or UCS groups. In the multivariate analysis, WCS placement and chemotherapy were identified as independent predictors of 16-week stent patency. CONCLUSIONS WCS group showed comparable migration rate and significantly more durable long-term stent patency compared with UCS group for the palliation of GOO in patients with inoperable gastric cancer.
Collapse
Affiliation(s)
- Hyuk Lee
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Byung-Hoon Min
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Jeong Hoon Lee
- Department of Gastroenterology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea
| | - Cheol Min Shin
- Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Younjoo Kim
- Division of Gastroenterology, Department of Internal Medicine, Korea Cancer Center Hospital, Korea Institute of Radiological and Medical Sciences, Seoul, Republic of Korea
| | - Hyunsoo Chung
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Sang Hyub Lee
- Department of Internal Medicine and Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea,Department of Internal Medicine and Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul 110-744, Republic of Korea. E-mail:
| |
Collapse
|
22
|
Hori Y, Naitoh I, Ban T, Narita K, Nakazawa T, Hayashi K, Miyabe K, Shimizu S, Kondo H, Nishi Y, Yoshida M, Umemura S, Kato A, Yamada T, Ando T, Joh T. Stent under-expansion on the procedure day, a predictive factor for poor oral intake after metallic stenting for gastric outlet obstruction. J Gastroenterol Hepatol 2015; 30:1246-51. [PMID: 25708096 DOI: 10.1111/jgh.12933] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 02/12/2015] [Indexed: 12/28/2022]
Abstract
BACKGROUND AND AIM Self-expandable metallic stents (SEMS) have been widely accepted as palliation therapy for malignant gastric outlet obstruction (GOO). However, the factors predictive of poor oral intake after SEMS placement have not been elucidated sufficiently. We aimed to clarify both the patient and stent-related predictive factors. METHODS We retrospectively reviewed 126 consecutive patients who underwent uncovered SEMS placement for malignant GOO between April 2010 and March 2013 at a university hospital and two tertiary care referral centers. RESULTS Technical success of SEMS placement was achieved in all 126 (100%) patients. Improved oral intake was observed in 111 (88.1%) patients. A Karnofsky performance status ≤ 40 (odds ratio [OR], 1.19; 95% confidence interval [CI], 1.02-1.28; P = 0.041), peritoneal dissemination (OR, 1.20; 95% CI, 1.01-1.26; P = 0.038), and under-expansion of the SEMS on the procedure day (OR, 1.55; 95% CI, 1.26-1.62; P < 0.001) were independent predictive factors for poor improvement on the GOO scoring system, according to multivariate analysis. CONCLUSIONS SEMS under-expansion was a stent related, while poor performance status and peritoneal dissemination were patient related, predictive factors for poor oral intake after SEMS placement for malignant GOO.
Collapse
Affiliation(s)
- Yasuki Hori
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Itaru Naitoh
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Tesshin Ban
- Department of Gastroenterology, Nagoya Daini Red cross Hospital, Nagoya, Japan
| | - Kei Narita
- Department of Gastroenterology, Gamagori City Hospital, Gamagori, Japan
| | - Takahiro Nakazawa
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Kazuki Hayashi
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Katsuyuki Miyabe
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Shuya Shimizu
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Hiromu Kondo
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Yuji Nishi
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Michihiro Yoshida
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Shuichiro Umemura
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Akihisa Kato
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Tomonori Yamada
- Department of Gastroenterology, Nagoya Daini Red cross Hospital, Nagoya, Japan
| | - Tomoaki Ando
- Department of Gastroenterology, Gamagori City Hospital, Gamagori, Japan
| | - Takashi Joh
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| |
Collapse
|