1
|
Gong J, Chen T, Tan Y, Liu D. Pocket-creation method improves efficacy of colorectal endoscopic submucosal dissection: a system review and meta-analysis. Eur J Gastroenterol Hepatol 2021; 33:1241-1246. [PMID: 32732811 DOI: 10.1097/meg.0000000000001864] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The pocket-creation method (PCM) is a new strategy for endoscopic submucosal dissection (ESD). The aim of this system review is to evaluate the clinical efficacy and safety of PCM-ESD compared to conventional ESD (C-ESD) for colorectal neoplasm lesions. We performed literature search using MEDLINE, EMBASE and CENTRAL database from inception to 15 February 2020. Studies provided comparison between PCM-ESD and C-ESD for colorectal neoplasm lesions were included. En bloc resection rate, R0 resection rate, occurrence rate of adverse events and operation speed/time were extracted from included studies. Pooled risk difference with 95% confidence intervals (CIs) was calculated in meta-analysis. Three cohort studies and one randomized control trial (RCT) were included, which contained 432 colorectal lesions removed by PCM-ESD and 959 lesions resected by C-ESD. PCM-ESD achieved significantly higher en bloc/R0 resection rate than C-ESD in cohort studies with pooled risk differences of 0.05 (CI, 0.03-0.07, I2 = 34%) and 0.14 (CI, 0.04-0.24, I2 = 83%). However, comparison of en bloc/R0 resection rate between two surgery strategies could not be estimated in RCT. Pooled results in cohort studies and data from RCT revealed comparable occurrence rate of adverse events between PCM-ESD and C-ESD. Measurements and outcomes of operation time/speed varied between the included studies and no consistent conclusion could be achieved in this aspect. The results indicate that PCM-ESD is an effective and well-tolerated treatment for colorectal neoplasm lesions and may be a superior treatment to C-ESD in en bloc/R0 resection rate.
Collapse
Affiliation(s)
- Jian Gong
- Department of Gastroenterology, The Second Xiangya Hospital, Central South University, Changsha, Hunan, China
| | | | | | | |
Collapse
|
2
|
Kuroki Y, Asonuma K, Uehara N, Endo T, Suzuki R, Yamamoto Y, Nagahama M. Efficacy and suitable indication of colorectal endoscopic submucosal dissection using a balloon-assisted endoscope. JGH Open 2020; 4:185-190. [PMID: 32280763 PMCID: PMC7144785 DOI: 10.1002/jgh3.12247] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2019] [Revised: 07/23/2019] [Accepted: 08/04/2019] [Indexed: 12/14/2022]
Abstract
Background and Aim Cases of colorectal endoscopic submucosal dissection (ESD) with poor maneuverability are often encountered. We aimed to evaluate the efficacy of balloon‐assisted endoscopy (BAE) for such cases. Methods We confirmed maneuverability preoperatively in 400 consecutive cases of colorectal ESD performed at a single center from April 2011 to April 2018. A total of 83 deep colon cases judged as having poor maneuverability were retrospectively reviewed; 54 cases underwent BAE with a single balloon endoscope (group B), and 29 cases underwent conventional procedures without BAE (group C). Tumor size, procedure duration, dissection speed, en bloc resection rate, histology, and associated complications were compared between groups. Results The mean tumor size, tumor invasiveness, fibrosis, and complications did not differ between groups. Although the en bloc resection rate did not differ (both 98%), the groups significantly differed with regard to the R0 resection rate (B: 96%; C: 83%; P = 0.048). Overall, the procedure duration (B: 51 min; C: 70 min; P = 0.17) and dissection speed (B: 19.4 mm2/min; C: 17.4 mm2/min; P = 0.13) were not significantly different between groups. However, the dissection speed for lesions in the cecum/ascending colon was significantly faster in group B than in group C (B: 22.3 mm2/min; C: 11.3 mm2/min; P = 0.037). Conclusions In cases of colorectal ESD with poor maneuverability, the use of BAE contributed to an improvement in the R0 resection rate. In addition, BAE contributed to a quicker dissection speed for lesions located in the cecum/ascending colon.
Collapse
Affiliation(s)
- Yuichiro Kuroki
- Department of Gastroenterology Showa University Fujigaoka Hospital Kanagawa Japan
| | - Kunio Asonuma
- Department of Gastroenterology Showa University Fujigaoka Hospital Kanagawa Japan
| | - Natsumi Uehara
- Department of Gastroenterology Showa University Fujigaoka Hospital Kanagawa Japan
| | - Toshiyuki Endo
- Department of Gastroenterology Showa University Fujigaoka Hospital Kanagawa Japan
| | - Reika Suzuki
- Department of Gastroenterology Showa University Fujigaoka Hospital Kanagawa Japan
| | - Yorimasa Yamamoto
- Department of Gastroenterology Showa University Fujigaoka Hospital Kanagawa Japan
| | - Masatsugu Nagahama
- Department of Gastroenterology Showa University Fujigaoka Hospital Kanagawa Japan
| |
Collapse
|
3
|
Sharma SK, Momose K, Sedrakyan A, Sonoda T, Sharaiha RZ. Endoscopic stabilization device evaluation using IDEAL framework: A quality improvement study. Int J Surg 2019; 67:18-23. [DOI: 10.1016/j.ijsu.2019.02.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Revised: 01/18/2019] [Accepted: 02/10/2019] [Indexed: 11/16/2022]
|
4
|
Yoshida N, Naito Y, Yasuda R, Murakami T, Hirose R, Ogiso K, Inada Y, Konishi H, Rani RA, Kishimoto M, Konishi E, Nakanishi M, Itoh Y. The efficacy of the pocket-creation method for cases with severe fibrosis in colorectal endoscopic submucosal dissection. Endosc Int Open 2018; 6:E975-E983. [PMID: 30083587 PMCID: PMC6075949 DOI: 10.1055/a-0593-5818] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2017] [Accepted: 02/26/2018] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND AND STUDY AIMS Severe fibrosis poses a challenge in colorectal endoscopic submucosal dissection (ESD). Recently, the pocket-creation method (PCM) has been developed for overcoming various difficulties of ESD. A specific tapered hood is used for adequate traction in the PCM, and endoscopic operability becomes stable in the pocket. In this study, we investigated the efficacy of the PCM in ESD for cases with severe fibrosis. PATIENTS AND METHODS We retrospectively reviewed 1000 consecutive colorectal ESD cases (April 2006 to January 2017). Since 2016, the PCM was performed in 58 cases. The indications for ESD included (1) tumors ≥ 20 mm in size diagnosed as intramucosal cancer or high-grade dysplasia and part of T1a cancer using magnifying endoscopic examinations and (2) tumors that appeared impossible to resect with endoscopic mucosal resection because of suspected fibrosis. We identified 120 cases with severe fibrosis and compared them to cases without severe fibrosis. Additionally, the 120 severe fibrosis cases were divided into the PCM and non-PCM groups. En bloc resection, procedure time, discontinuation, and complications were analyzed between these 2 groups. RESULTS Among all 1000 ESDs, severe fibrosis and discontinuation rates were 12.0 % (120 cases) and 1.8 % (18 cases), respectively. Regarding the comparison between cases with severe fibrosis and with no severe fibrosis, there were significant differences about en bloc resection rate (78.3 % vs. 95.7 %, P < 0.001), discontinuance rate (12.5 % vs. 0.3 %, P < 0.001), and perforation rate (8.3 % vs. 2.6 %, P = 0.001). Among the 120 cases with severe fibrosis, 21 and 99 cases were in the PCM and non-PCM groups, respectively. The PCM group had a higher en bloc resection rate (95.2 vs. 74.7, P = 0.03), a shorter mean procedure time (min) (79.6 ± 26.5 vs. 118.8 ± 71.0, P = 0.001), and no cases of discontinuation. An analysis of the interobserver agreement for the diagnosis of severe fibrosis among the 3 endoscopists showed kappa values of > 0.6. CONCLUSIONS In cases with severe fibrosis, the PCM with ESD improved en bloc resection rates and shortened the procedure time compared to the conventional non-PCM method. Additionally, the PCM reduced the discontinuation rate.
Collapse
Affiliation(s)
- Naohisa Yoshida
- Department of Molecular Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan
| | - Yuji Naito
- Department of Molecular Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan
| | - Ritsu Yasuda
- Department of Molecular Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan
| | - Takaaki Murakami
- Department of Molecular Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan
| | - Ryohei Hirose
- Department of Molecular Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan
| | - Kiyoshi Ogiso
- Department of Molecular Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan
| | - Yutaka Inada
- Department of Molecular Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan
| | - Hideyuki Konishi
- Department of Molecular Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan
| | - Rafiz Abdul Rani
- Gastroenterology Unit, Faculty of Medicine, Universiti Teknologi MARA, Selangor, Malaysia
| | - Mitsuo Kishimoto
- Department of Surgical Pathology, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan
| | - Eiichi Konishi
- Department of Surgical Pathology, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan
| | - Masayoshi Nakanishi
- Department of Surgery, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan
| | - Yoshito Itoh
- Department of Molecular Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan
| |
Collapse
|
5
|
Sharma SK, Hiratsuka T, Hara H, Milsom JW. Antigravity ESD - double-balloon-assisted underwater with traction hybrid technique. Endosc Int Open 2018; 6:E739-E744. [PMID: 29876511 PMCID: PMC5988544 DOI: 10.1055/a-0578-8081] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Accepted: 02/05/2018] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND AND STUDY AIMS Complex colorectal polyps or those positioned in difficult anatomic locations are an endoscopic therapeutic challenge. Underwater endoscopic submucosal dissection (UESD) is a potential technical solution to facilitate efficient polyp removal. In addition, endoscopic tissue retraction has been confined to limited methods of varying efficacy and complexity. The aim of this study was to evaluate the efficiency of a unique UESD technique for removing complex polyps using double-balloon-assisted retraction (R). MATERIALS AND METHODS Using fresh ex-vivo porcine rectum, 4-cm polyps were created using electrosurgery and positioned at "6 o'clock" within an established ESD model. Six resections were performed in each group. Underwater techniques were facilitated using a novel double-balloon platform (Dilumen, Lumendi, Westport, Connecticut, United States). RESULTS UESD-R had a significantly shorter total procedural time than cap-assisted ESD and UESD alone (24 vs. 58 vs. 56 mins). UESD-R produced a dissection time on average of 5 minutes, attributed to the retraction provided. There was also a subjective significant reduction in electrosurgical smoke with the underwater techniques contributing to improved visualization. CONCLUSIONS Here we report the first ex-vivo experience of a unique double-balloon endoscopic platform optimized for UESD with tissue traction capability. UESD-R removed complex lesions in significantly shorter time than conventional means. The combined benefits of UESD and retraction appeared to be additive when tackling complex polyps and should be studied further.
Collapse
Affiliation(s)
- Sam K. Sharma
- Minimally Invasive New Technologies, Department of Surgery, Weill Cornell Medicine, New York Presbyterian Hospital, New York, New York, United States,Corresponding author Sam K. Sharma Minimally Invasive New TechnologiesDepartment of Surgery, Weill Cornell Medicine, New York Presbyterian HospitalNew York, New YorkUnited States212-746-8750
| | - Takahiro Hiratsuka
- Minimally Invasive New Technologies, Department of Surgery, Weill Cornell Medicine, New York Presbyterian Hospital, New York, New York, United States
| | - Hisashi Hara
- Minimally Invasive New Technologies, Department of Surgery, Weill Cornell Medicine, New York Presbyterian Hospital, New York, New York, United States
| | - Jeffrey W. Milsom
- Minimally Invasive New Technologies, Department of Surgery, Weill Cornell Medicine, New York Presbyterian Hospital, New York, New York, United States
| |
Collapse
|
6
|
Trindade AJ, Lichtenstein DR, Aslanian HR, Bhutani MS, Goodman A, Melson J, Navaneethan U, Pannala R, Parsi MA, Sethi A, Sullivan S, Thosani N, Trikudanathan G, Watson RR, Maple JT. Devices and methods to improve colonoscopy completion (with videos). Gastrointest Endosc 2018; 87:625-634. [PMID: 29454445 DOI: 10.1016/j.gie.2017.12.011] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Accepted: 12/22/2017] [Indexed: 02/08/2023]
|
7
|
Ponte A, Pinho R, Rodrigues A, Proença L, Silva J, Rodrigues JP, Sousa M, Carlos Silva J, Carvalho J. High Efficacy of Repeating Colonoscopy by an Advanced Endoscopist after an Incomplete Colonoscopy. GE-PORTUGUESE JOURNAL OF GASTROENTEROLOGY 2018; 25:285-290. [PMID: 30480045 DOI: 10.1159/000485803] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2017] [Accepted: 11/28/2017] [Indexed: 12/25/2022]
Abstract
Background and Aims This study aims to evaluate the role of an advanced endoscopist to study the entire colon after an incomplete colonoscopy. Methods All patients with an elective incomplete colonoscopy performed under deep sedation in our department between January 2010 and October 2016 were included. Patients with a colonic stenosis, an inadequate bowel preparation, or a colonoscopy performed without deep sedation were excluded. Included patients were followed up to evaluate if and what type of subsequent examinations (colonoscopy by an advanced endoscopist, single-balloon enteroscopy [SBE], and/or CT colonography) was performed to complete the study of the entire colon. Lesions found during these subsequent examinations were also recorded. Results Ninety-three patients had an incomplete colonoscopy, with no diagnosis of colorectal cancer (CRC) and a high-risk polyp rate of 5.4% (n = 5). Seventy-seven patients with incomplete colonoscopies underwent subsequent examinations, namely CT colonography in 45.5% (n = 35), colonoscopy by an advanced endoscopist in 53.2% (n = 41), and SBE in 13% (n = 10). In the 49 patients who performed either colonoscopy (n = 39) or SBE (n = 10) by an advanced endoscopist, the cecal intubation rate was 100%, and high-risk polyps were found in 26.5% (n = 13) and CRC in 4.1%. CT colonography revealed findings consistent with polyps and CRC in 22.9% (n = 8) and 2.9% (n = 1) of the cases, respectively. Colonoscopy was further repeated in 6 patients with suspected polyps in CT colonography, confirming the initial diagnosis in 5 patients. Conclusions Colonoscopy by an advanced endoscopist achieved cecal intubation in all patients, representing a good choice after an incomplete colonoscopy.
Collapse
Affiliation(s)
- Ana Ponte
- Department of Gastroenterology, Centro Hospitalar Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Portugal
| | - Rolando Pinho
- Department of Gastroenterology, Centro Hospitalar Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Portugal
| | - Adélia Rodrigues
- Department of Gastroenterology, Centro Hospitalar Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Portugal
| | - Luísa Proença
- Department of Gastroenterology, Centro Hospitalar Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Portugal
| | - Joana Silva
- Department of Gastroenterology, Centro Hospitalar Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Portugal
| | - Jaime P Rodrigues
- Department of Gastroenterology, Centro Hospitalar Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Portugal
| | - Mafalda Sousa
- Department of Gastroenterology, Centro Hospitalar Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Portugal
| | - João Carlos Silva
- Department of Gastroenterology, Centro Hospitalar Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Portugal
| | - João Carvalho
- Department of Gastroenterology, Centro Hospitalar Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Portugal
| |
Collapse
|
8
|
Hermans C, Zee DVD, Gilissen L. Double-Balloon Endoscopy after Incomplete Colonoscopy and Its Comparison with Computed Tomography Colonography. Clin Endosc 2018; 51:66-71. [PMID: 29316779 PMCID: PMC5806920 DOI: 10.5946/ce.2017.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2016] [Revised: 10/08/2017] [Accepted: 10/25/2017] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND/AIMS Because of the national screening program for colorectal carcinoma in The Netherlands, the number of colonoscopies has increased. In case of incomplete colonoscopy, computed tomography colonography (CTC) and double-balloon colonoscopy (DBc) are alternative options. This study evaluated cecal intubation rate and pathology detection rate in the previously unexplored part of the colon, complication rate of DBc, and CTC results after incomplete colonoscopy. METHODS Retrospective observational study in a tertiary referral hospital regarding DBc and CTC reports from cases with incomplete colonoscopy. RESULTS Sixty-three DBcs were performed after incomplete colonoscopy. Cecal intubation rate was 95%. Detection rate was 58% (5% carcinoma and 3% high-grade dysplastic adenoma). CTC preceded 54% of DBcs and 62% of CTC findings were confirmed. In 16%, a biopsy was taken, and in 60%, an intervention (mostly polypectomy) was performed. One major complication (1.5%) occurred, i.e., arterial bleeding due to polypectomy necessitating right hemicolectomy. CTC (n=213) showed a possible lesion in 35%, and could be confirmed by follow-up endoscopy or surgery in 65%. CONCLUSIONS DBc is effective and safe for completion of colon inspection in incomplete colonoscopy. In patients with a high likelihood of pathology, DBc is preferred over CTC.
Collapse
Affiliation(s)
- Carlijn Hermans
- Department of Gastroenterology and Hepatology, Catharina Hospital Eindhoven, Eindhoven, Netherlands
| | - Dennis van der Zee
- Department of Radiology, Catharina Hospital Eindhoven, Eindhoven, Netherlands
| | - Lennard Gilissen
- Department of Gastroenterology and Hepatology, Catharina Hospital Eindhoven, Eindhoven, Netherlands
| |
Collapse
|
9
|
Yoshida N, Toyonaga T, Murakami T, Hirose R, Ogiso K, Inada Y, Rani RA, Naito Y, Kishimoto M, Ohara Y, Azuma T, Itoh Y. Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection. Gastroenterol Res Pract 2017; 2017:5897369. [PMID: 29081793 PMCID: PMC5610827 DOI: 10.1155/2017/5897369] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2017] [Revised: 07/05/2017] [Accepted: 07/13/2017] [Indexed: 12/16/2022] Open
Abstract
BACKGROUNDS With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). METHODS In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. RESULTS The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p < 0.001, vacuum amount: 38.0 versus 14.0, p < 0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1-28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. CONCLUSIONS Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results.
Collapse
Affiliation(s)
- Naohisa Yoshida
- Department of Molecular Gastroenterology and Hepatology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | | | - Takaaki Murakami
- Department of Molecular Gastroenterology and Hepatology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Ryohei Hirose
- Department of Molecular Gastroenterology and Hepatology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Kiyoshi Ogiso
- Department of Molecular Gastroenterology and Hepatology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Yutaka Inada
- Department of Molecular Gastroenterology and Hepatology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Rafiz Abdul Rani
- Department of Molecular Gastroenterology and Hepatology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Yuji Naito
- Department of Molecular Gastroenterology and Hepatology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Mitsuo Kishimoto
- Department of Surgical Pathology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Yoshiko Ohara
- Department of Endoscopy, Kobe University Hospital, Hyogo, Japan
| | - Takeshi Azuma
- Division of Gastroenterology, Department of Internal Medicine, Graduate School of Medicine, Kobe University, Kobe, Japan
| | - Yoshito Itoh
- Department of Molecular Gastroenterology and Hepatology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| |
Collapse
|