1
|
Busia P, Cossettini A, Ingolfsson TM, Benatti S, Burrello A, Jung VJB, Scherer M, Scrugli MA, Bernini A, Ducouret P, Ryvlin P, Meloni P, Benini L. Reducing False Alarms in Wearable Seizure Detection With EEGformer: A Compact Transformer Model for MCUs. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2024; 18:608-621. [PMID: 38261487 DOI: 10.1109/tbcas.2024.3357509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2024]
Abstract
The long-term, continuous analysis of electroencephalography (EEG) signals on wearable devices to automatically detect seizures in epileptic patients is a high-potential application field for deep neural networks, and specifically for transformers, which are highly suited for end-to-end time series processing without handcrafted feature extraction. In this work, we propose a small-scale transformer detector, the EEGformer, compatible with unobtrusive acquisition setups that use only the temporal channels. EEGformer is the result of a hardware-oriented design exploration, aiming for efficient execution on tiny low-power micro-controller units (MCUs) and low latency and false alarm rate to increase patient and caregiver acceptance.Tests conducted on the CHB-MIT dataset show a 20% reduction of the onset detection latency with respect to the state-of-the-art model for temporal acquisition, with a competitive 73% seizure detection probability and 0.15 false-positive-per-hour (FP/h). Further investigations on a novel and challenging scalp EEG dataset result in the successful detection of 88% of the annotated seizure events, with 0.45 FP/h.We evaluate the deployment of the EEGformer on three commercial low-power computing platforms: the single-core Apollo4 MCU and the GAP8 and GAP9 parallel MCUs. The most efficient implementation (on GAP9) results in as low as 13.7 ms and 0.31 mJ per inference, demonstrating the feasibility of deploying the EEGformer on wearable seizure detection systems with reduced channel count and multi-day battery duration.
Collapse
|
2
|
Vakilna YS, Li X, Hampson JS, Huang Y, Mosher JC, Dabaghian Y, Luo X, Talavera B, Pati S, Todd M, Hays R, Szabo CA, Zhang GQ, Lhatoo SD. Reliable detection of generalized convulsive seizures using an off-the-shelf digital watch: A multisite phase 2 study. Epilepsia 2024. [PMID: 38738972 DOI: 10.1111/epi.17974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 03/19/2024] [Accepted: 03/25/2024] [Indexed: 05/14/2024]
Abstract
OBJECTIVE The aim of this study was to develop a machine learning algorithm using an off-the-shelf digital watch, the Samsung watch (SM-R800), and evaluate its effectiveness for the detection of generalized convulsive seizures (GCS) in persons with epilepsy. METHODS This multisite epilepsy monitoring unit (EMU) phase 2 study included 36 adult patients. Each patient wore a Samsung watch that contained accelerometer, gyroscope, and photoplethysmographic sensors. Sixty-eight time and frequency domain features were extracted from the sensor data and were used to train a random forest algorithm. A testing framework was developed that would better reflect the EMU setting, consisting of (1) leave-one-patient-out cross-validation (LOPO CV) on GCS patients, (2) false alarm rate (FAR) testing on nonseizure patients, and (3) "fixed-and-frozen" prospective testing on a prospective patient cohort. Balanced accuracy, precision, sensitivity, and FAR were used to quantify the performance of the algorithm. Seizure onsets and offsets were determined by using video-electroencephalographic (EEG) monitoring. Feature importance was calculated as the mean decrease in Gini impurity during the LOPO CV testing. RESULTS LOPO CV results showed balanced accuracy of .93 (95% confidence interval [CI] = .8-.98), precision of .68 (95% CI = .46-.85), sensitivity of .87 (95% CI = .62-.96), and FAR of .21/24 h (interquartile range [IQR] = 0-.90). Testing the algorithm on patients without seizure resulted in an FAR of .28/24 h (IQR = 0-.61). During the "fixed-and-frozen" prospective testing, two patients had three GCS, which were detected by the algorithm, while generating an FAR of .25/24 h (IQR = 0-.89). Feature importance showed that heart rate-based features outperformed accelerometer/gyroscope-based features. SIGNIFICANCE Commercially available wearable digital watches that reliably detect GCS, with minimum false alarm rates, may overcome usage adoption and other limitations of custom-built devices. Contingent on the outcomes of a prospective phase 3 study, such devices have the potential to provide non-EEG-based seizure surveillance and forecasting in the clinical setting.
Collapse
Affiliation(s)
- Yash Shashank Vakilna
- Department of Neurology, University of Texas Health Science Center at Houston, Houston, Texas, USA
- Texas Institute of Restorative Neurotechnologies, University of Texas Health Science Center at Houston, Houston, Texas, USA
| | - Xiaojin Li
- Department of Neurology, University of Texas Health Science Center at Houston, Houston, Texas, USA
- Texas Institute of Restorative Neurotechnologies, University of Texas Health Science Center at Houston, Houston, Texas, USA
| | - Jaison S Hampson
- Department of Neurology, University of Texas Health Science Center at Houston, Houston, Texas, USA
- Texas Institute of Restorative Neurotechnologies, University of Texas Health Science Center at Houston, Houston, Texas, USA
| | - Yan Huang
- Department of Neurology, University of Texas Health Science Center at Houston, Houston, Texas, USA
- Texas Institute of Restorative Neurotechnologies, University of Texas Health Science Center at Houston, Houston, Texas, USA
| | - John C Mosher
- Department of Neurology, University of Texas Health Science Center at Houston, Houston, Texas, USA
- Texas Institute of Restorative Neurotechnologies, University of Texas Health Science Center at Houston, Houston, Texas, USA
| | - Yuri Dabaghian
- Department of Neurology, University of Texas Health Science Center at Houston, Houston, Texas, USA
- Texas Institute of Restorative Neurotechnologies, University of Texas Health Science Center at Houston, Houston, Texas, USA
| | - Xi Luo
- Department of Biostatistics and Data Science, University of Texas Health Science Center at Houston, Houston, Texas, USA
| | - Blanca Talavera
- Department of Neurology, University of Texas Health Science Center at Houston, Houston, Texas, USA
- Texas Institute of Restorative Neurotechnologies, University of Texas Health Science Center at Houston, Houston, Texas, USA
| | - Sandipan Pati
- Department of Neurology, University of Texas Health Science Center at Houston, Houston, Texas, USA
- Texas Institute of Restorative Neurotechnologies, University of Texas Health Science Center at Houston, Houston, Texas, USA
| | - Masel Todd
- Department of Neurology, University of Texas Medical Branch, Galveston, Texas, USA
| | - Ryan Hays
- Department of Neurology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Charles Akos Szabo
- Department of Neurology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
| | - Guo-Qiang Zhang
- Department of Neurology, University of Texas Health Science Center at Houston, Houston, Texas, USA
- Texas Institute of Restorative Neurotechnologies, University of Texas Health Science Center at Houston, Houston, Texas, USA
| | - Samden D Lhatoo
- Department of Neurology, University of Texas Health Science Center at Houston, Houston, Texas, USA
- Texas Institute of Restorative Neurotechnologies, University of Texas Health Science Center at Houston, Houston, Texas, USA
| |
Collapse
|
3
|
Komal K, Cleary F, Wells JSG, Bennett L. A systematic review of the literature reporting on remote monitoring epileptic seizure detection devices. Epilepsy Res 2024; 201:107334. [PMID: 38442551 DOI: 10.1016/j.eplepsyres.2024.107334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 02/19/2024] [Accepted: 02/26/2024] [Indexed: 03/07/2024]
Abstract
BACKGROUND Early detection and alert notification of an impending seizure for people with epilepsy have the potential to reduce Sudden Unexpected Death in Epilepsy (SUDEP). Current remote monitoring seizure detection devices for people with epilepsy are designed to support real-time monitoring of their vital health parameters linked to seizure alert notification. An understanding of the rapidly growing literature on remote seizure detection devices is essential to address the needs of people with epilepsy and their carers. AIM This review aims to examine the technical characteristics, device performance, user preference, and effectiveness of remote monitoring seizure detection devices. METHODOLOGY A systematic review referenced to PRISMA guidelines was used. RESULTS A total of 1095 papers were identified from the initial search with 30 papers included in the review. Sixteen non-invasive remote monitoring seizure detection devices are currently available. Such seizure detection devices were found to have inbuilt intelligent sensor functionality to monitor electroencephalography, muscle movement, and accelerometer-based motion movement for detecting seizures remotely. Current challenges of these devices for people with epilepsy include skin irritation due to the type of patch electrode used and false alarm notifications, particularly during physical activity. The tight-fitted accelerometer-type devices are reported as uncomfortable from a wearability perspective for long-term monitoring. Also, continuous recording of physiological signals and triggering alert notifications significantly reduce the battery life of the devices. The literature highlights that 3.2 out of 5 people with epilepsy are not using seizure detection devices because of the cost and appearance of the device. CONCLUSION Seizure detection devices can potentially reduce morbidity and mortality for people with epilepsy. Therefore, further collaboration of clinicians, technical experts, and researchers is needed for the future development of these devices. Finally, it is important to always take into consideration the expectations and requirements of people with epilepsy and their carers to facilitate the next generation of remote monitoring seizure detection devices.
Collapse
Affiliation(s)
- K Komal
- School of Health Sciences, South East Technological University, Cork Road, Waterford, Ireland; Walton Institute, South East Technological University, Cork Road, Waterford, Ireland.
| | - F Cleary
- Walton Institute, South East Technological University, Cork Road, Waterford, Ireland
| | - J S G Wells
- School of Health Sciences, South East Technological University, Cork Road, Waterford, Ireland
| | - L Bennett
- School of Health Sciences, South East Technological University, Cork Road, Waterford, Ireland
| |
Collapse
|
4
|
Rehman M, Higdon LM, Sperling MR. Long-Term Home EEG Recording: Wearable and Implantable Devices. J Clin Neurophysiol 2024; 41:200-206. [PMID: 38436387 DOI: 10.1097/wnp.0000000000001014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/05/2024] Open
Abstract
SUMMARY Electroencephalography (EEG) monitoring has served as a cornerstone in the diagnostic and therapeutic evaluation of epilepsy since its development. This has been accomplished with short-term inpatient video-EEG hospitalization enabling observation of both the semiological and the electrographic features of seizures or with short-term home ambulatory EEG or video-EEG. The advantages of inpatient video-EEG monitoring are limited by high cost, inconvenience, and inability to monitor patients for long periods (weeks or months) as might be done in the outpatient setting. This limitation has impelled the development of wearable EEG devices, which aim to capture high-quality long-term EEG data in a user-friendly and unobtrusive manner. This review article aims to summarize three broad categories of wearable EEG devices, including scalp, subcutaneous, and intracranial EEG. In this review, we will discuss the features of each type of device and the implications for the management of epilepsy. This review does not aim to describe every wearable EEG device on the market but instead seeks to provide a broad overview of the various categories of device that are available, giving examples of each and those in development (with no intention to recommend or advocate for any particular product).
Collapse
Affiliation(s)
- Mahnoor Rehman
- Department of Neurology, Jefferson Comprehensive Epilepsy Center, Thomas Jefferson University, Philadelphia, Pennsylvania
| | | | | |
Collapse
|
5
|
Donner E, Devinsky O, Friedman D. Wearable Digital Health Technology for Epilepsy. N Engl J Med 2024; 390:736-745. [PMID: 38381676 DOI: 10.1056/nejmra2301913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Affiliation(s)
- Elizabeth Donner
- From the Division of Neurology, Hospital for Sick Children, and the Department of Paediatrics, University of Toronto - both in Toronto (E.D.); and the Epilepsy Center, Department of Neurology, New York University Grossman School of Medicine, New York (O.D., D.F.)
| | - Orrin Devinsky
- From the Division of Neurology, Hospital for Sick Children, and the Department of Paediatrics, University of Toronto - both in Toronto (E.D.); and the Epilepsy Center, Department of Neurology, New York University Grossman School of Medicine, New York (O.D., D.F.)
| | - Daniel Friedman
- From the Division of Neurology, Hospital for Sick Children, and the Department of Paediatrics, University of Toronto - both in Toronto (E.D.); and the Epilepsy Center, Department of Neurology, New York University Grossman School of Medicine, New York (O.D., D.F.)
| |
Collapse
|
6
|
Ingolfsson TM, Benatti S, Wang X, Bernini A, Ducouret P, Ryvlin P, Beniczky S, Benini L, Cossettini A. Minimizing artifact-induced false-alarms for seizure detection in wearable EEG devices with gradient-boosted tree classifiers. Sci Rep 2024; 14:2980. [PMID: 38316856 PMCID: PMC10844293 DOI: 10.1038/s41598-024-52551-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 01/19/2024] [Indexed: 02/07/2024] Open
Abstract
Electroencephalography (EEG) is widely used to monitor epileptic seizures, and standard clinical practice consists of monitoring patients in dedicated epilepsy monitoring units via video surveillance and cumbersome EEG caps. Such a setting is not compatible with long-term tracking under typical living conditions, thereby motivating the development of unobtrusive wearable solutions. However, wearable EEG devices present the challenges of fewer channels, restricted computational capabilities, and lower signal-to-noise ratio. Moreover, artifacts presenting morphological similarities to seizures act as major noise sources and can be misinterpreted as seizures. This paper presents a combined seizure and artifacts detection framework targeting wearable EEG devices based on Gradient Boosted Trees. The seizure detector achieves nearly zero false alarms with average sensitivity values of [Formula: see text] for 182 seizures from the CHB-MIT dataset and [Formula: see text] for 25 seizures from the private dataset with no preliminary artifact detection or removal. The artifact detector achieves a state-of-the-art accuracy of [Formula: see text] (on the TUH-EEG Artifact Corpus dataset). Integrating artifact and seizure detection significantly reduces false alarms-up to [Formula: see text] compared to standalone seizure detection. Optimized for a Parallel Ultra-Low Power platform, these algorithms enable extended monitoring with a battery lifespan reaching 300 h. These findings highlight the benefits of integrating artifact detection in wearable epilepsy monitoring devices to limit the number of false positives.
Collapse
Affiliation(s)
| | - Simone Benatti
- University of Bologna, 40126, Bologna, Italy
- University of Modena and Reggio Emilia, 41121, Reggio Emilia, Italy
| | | | - Adriano Bernini
- University Hospital of Lausanne (CHUV), 1011, Lausanne, Switzerland
| | - Pauline Ducouret
- University Hospital of Lausanne (CHUV), 1011, Lausanne, Switzerland
| | - Philippe Ryvlin
- University Hospital of Lausanne (CHUV), 1011, Lausanne, Switzerland
| | - Sandor Beniczky
- Aarhus University Hospital, 8200, Aarhus, Denmark
- Danish Epilepsy Centre (Filadelfia), 4293, Dianalund, Denmark
| | - Luca Benini
- ETH Zürich, D-ITET, 8092, Zürich, Switzerland
- University of Bologna, 40126, Bologna, Italy
| | | |
Collapse
|
7
|
Wong S, Simmons A, Rivera-Villicana J, Barnett S, Sivathamboo S, Perucca P, Kwan P, Kuhlmann L, Vasa R, O'Brien TJ. EEG based automated seizure detection - A survey of medical professionals. Epilepsy Behav 2023; 149:109518. [PMID: 37952416 DOI: 10.1016/j.yebeh.2023.109518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 10/29/2023] [Accepted: 11/02/2023] [Indexed: 11/14/2023]
Abstract
Diagnosing and managing seizures presents substantial challenges for clinicians caring for patients with epilepsy. Although machine learning (ML) has been proposed for automated seizure detection using EEG data, there is little evidence of these technologies being broadly adopted in clinical practice. Moreover, there is a noticeable lack of surveys investigating this topic from the perspective of medical practitioners, which limits the understanding of the obstacles for the development of effective automated seizure detection. Besides the issue of generalisability and replicability seen in a small amount of studies, obstacles to the adoption of automated seizure detection remain largely unknown. To understand the obstacles preventing the application of seizure detection tools in clinical practice, we conducted a survey targeting medical professionals involved in the management of epilepsy. Our study aimed to gather insights on various factors such as the clinical utility, professional sentiment, benchmark requirements, and perceived barriers associated with the use of automated seizure detection tools. Our key findings are: I) The minimum acceptable sensitivity reported by most of our respondents (80%) seems achievable based on studies reported from most currently available ML-based EEG seizure detection algorithms, but replication studies often fail to meet this minimum. II) Respondents are receptive to the adoption of ML seizure detection tools and willing to spend time in training. III) The top three barriers for usage of such tools in clinical practice are related to availability, lack of training, and the blackbox nature of ML algorithms. Based on our findings, we developed a guide that can serve as a basis for developing ML-based seizure detection tools that meet the requirements of medical professionals, and foster the integration of these tools into clinical practice.
Collapse
Affiliation(s)
- Sheng Wong
- Applied Artificial Intelligence Institute, Deakin University, Burwood, Victoria, Australia.
| | - Anj Simmons
- Applied Artificial Intelligence Institute, Deakin University, Burwood, Victoria, Australia
| | | | - Scott Barnett
- Applied Artificial Intelligence Institute, Deakin University, Burwood, Victoria, Australia
| | - Shobi Sivathamboo
- Department of Neuroscience, Central Clinical School, Monash University, Melbourne, Victoria, Australia; Department of Neurology, Alfred Health, Melbourne, Victoria, Australia; Department of Medicine, The Royal Melbourne Hospital, The University of Melbourne, Parkville, Victoria, Australia; Department of Neurology, The Royal Melbourne Hospital, Parkville, Victoria, Australia
| | - Piero Perucca
- Department of Neurology, Alfred Health, Melbourne, Victoria, Australia; Department of Medicine, The Royal Melbourne Hospital, The University of Melbourne, Parkville, Victoria, Australia; Department of Neurology, The Royal Melbourne Hospital, Parkville, Victoria, Australia; Epilepsy Research Centre, Department of Medicine (Austin Health), The University of Melbourne, Heidelberg, Victoria, Australia; Bladin-Berkovic Comprehensive Epilepsy Program, Austin Health, Heidelberg, Victoria, Australia
| | - Patrick Kwan
- Department of Neuroscience, Central Clinical School, Monash University, Melbourne, Victoria, Australia; Department of Neurology, Alfred Health, Melbourne, Victoria, Australia; Department of Medicine, The Royal Melbourne Hospital, The University of Melbourne, Parkville, Victoria, Australia; Department of Neurology, The Royal Melbourne Hospital, Parkville, Victoria, Australia
| | - Levin Kuhlmann
- Department of Data Science and AI, Faculty of IT, Monash University, Clayton, Victoria, Australia; Department of Medicine, St Vincent's Hospital, The University of Melbourne, Melbourne, Victoria, Australia
| | - Rajesh Vasa
- Applied Artificial Intelligence Institute, Deakin University, Burwood, Victoria, Australia
| | - Terence J O'Brien
- Department of Neuroscience, Central Clinical School, Monash University, Melbourne, Victoria, Australia; Department of Neurology, Alfred Health, Melbourne, Victoria, Australia; Department of Medicine, The Royal Melbourne Hospital, The University of Melbourne, Parkville, Victoria, Australia; Department of Neurology, The Royal Melbourne Hospital, Parkville, Victoria, Australia
| |
Collapse
|
8
|
Abreu M, Carmo AS, Peralta AR, Sá F, Plácido da Silva H, Bentes C, Fred AL. PreEpiSeizures: description and outcomes of physiological data acquisition using wearable devices during video-EEG monitoring in people with epilepsy. Front Physiol 2023; 14:1248899. [PMID: 37881691 PMCID: PMC10597694 DOI: 10.3389/fphys.2023.1248899] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 09/04/2023] [Indexed: 10/27/2023] Open
Abstract
The PreEpiSeizures project was created to better understand epilepsy and seizures through wearable technologies. The motivation was to capture physiological information related to epileptic seizures, besides Electroencephalography (EEG) during video-EEG monitorings. If other physiological signals have reliable information of epileptic seizures, unobtrusive wearable technology could be used to monitor epilepsy in daily life. The development of wearable solutions for epilepsy is limited by the nonexistence of datasets which could validate these solutions. Three different form factors were developed and deployed, and the signal quality was assessed for all acquired biosignals. The wearable data acquisition was performed during the video-EEG of patients with epilepsy. The results achieved so far include 59 patients from 2 hospitals totaling 2,721 h of wearable data and 348 seizures. Besides the wearable data, the Electrocardiogram of the hospital is also useable, totalling 5,838 h of hospital data. The quality ECG signals collected with the proposed wearable is equated with the hospital system, and all other biosignals also achieved state-of-the-art quality. During the data acquisition, 18 challenges were identified, and are presented alongside their possible solutions. Though this is an ongoing work, there were many lessons learned which could help to predict possible problems in wearable data collections and also contribute to the epilepsy community with new physiological information. This work contributes with original wearable data and results relevant to epilepsy research, and discusses relevant challenges that impact wearable health monitoring.
Collapse
Affiliation(s)
- Mariana Abreu
- Instituto de Telecomunicações, Lisboa, Portugal
- Departamento de Bioengenharia, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - Ana Sofia Carmo
- Instituto de Telecomunicações, Lisboa, Portugal
- Departamento de Bioengenharia, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - Ana Rita Peralta
- Lab EEG-Sono, Centro Hospitalar Universitário Lisboa Norte, Hospital de Santa Maria, Lisboa, Portugal
| | - Francisca Sá
- Departamento Neurologia, Centro Hospitalar Lisboa Ocidental, Hospital Egas Moniz, Lisboa, Portugal
| | - Hugo Plácido da Silva
- Instituto de Telecomunicações, Lisboa, Portugal
- Departamento de Bioengenharia, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
- Lisbon Unit for Learning and Intelligent Systems (LUMLIS), A Unit of the European Laboratory for Learning and Intelligent Systems (ELLIS), Lisboa, Portugal
| | - Carla Bentes
- Lab EEG-Sono, Centro Hospitalar Universitário Lisboa Norte, Hospital de Santa Maria, Lisboa, Portugal
| | - Ana Luísa Fred
- Instituto de Telecomunicações, Lisboa, Portugal
- Departamento de Bioengenharia, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| |
Collapse
|
9
|
Garção VM, Abreu M, Peralta AR, Bentes C, Fred A, P da Silva H. A novel approach to automatic seizure detection using computer vision and independent component analysis. Epilepsia 2023; 64:2472-2483. [PMID: 37301976 DOI: 10.1111/epi.17677] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 06/06/2023] [Accepted: 06/07/2023] [Indexed: 06/12/2023]
Abstract
OBJECTIVE Epilepsy is a neurological disease that affects ~50 million people worldwide, 30% of which have refractory epilepsy and recurring seizures, which may contribute to higher anxiety levels and poorer quality of life. Seizure detection may contribute to addressing some of the challenges associated with this condition, by providing information to health professionals regarding seizure frequency, type, and/or location in the brain, thereby improving diagnostic accuracy and medication adjustment, and alerting caregivers or emergency services of dangerous seizure episodes. The main focus of this work was the development of an accurate video-based seizure-detection method that ensured unobtrusiveness and privacy preservation, and provided novel approaches to reduce confounds and increase reliability. METHODS The proposed approach is a video-based seizure-detection method based on optical flow, principal component analysis, independent component analysis, and machine learning classification. This method was tested on a set of 21 tonic-clonic seizure videos (5-30 min each, total of 4 h and 36 min of recordings) from 12 patients using leave-one-subject-out cross-validation. RESULTS High accuracy levels were observed, namely a sensitivity and specificity of 99.06% ± 1.65% at the equal error rate and an average latency of 37.45 ± 1.31 s. When compared to annotations by health care professionals, the beginning and ending of seizures was detected with an average offset of 9.69 ± 0.97 s. SIGNIFICANCE The video-based seizure-detection method described herein is highly accurate. Moreover, it is intrinsically privacy preserving, due to the use of optical flow motion quantification. In addition, given our novel independence-based approach, this method is robust to different lighting conditions, partial occlusions of the patient, and other movements in the video frame, thereby setting the base for accurate and unobtrusive seizure detection.
Collapse
Affiliation(s)
- Vicente M Garção
- Department of Bioengineering (DBE), Instituto de Telecomunicações (IT), Instituto Superior Técnico (IST), Lisbon, Portugal
| | - Mariana Abreu
- Department of Bioengineering (DBE), Instituto de Telecomunicações (IT), Instituto Superior Técnico (IST), Lisbon, Portugal
| | - Ana R Peralta
- Centro de Referência para a área de Epilepsia Refratária (Member of the ERN-EpiCARE) at the Department of Neurosciences and Mental Health of Hospital de Santa Maria, Centro Hospitalar Universitário Lisboa Norte, Lisbon, Portugal
- Centro de Estudos Egas Moniz at Faculdade de Medicina da Universidade de Lisboa (FMUL), Av. Prof. Egas Moniz, Lisbon, Portugal
| | - Carla Bentes
- Centro de Referência para a área de Epilepsia Refratária (Member of the ERN-EpiCARE) at the Department of Neurosciences and Mental Health of Hospital de Santa Maria, Centro Hospitalar Universitário Lisboa Norte, Lisbon, Portugal
- Centro de Estudos Egas Moniz at Faculdade de Medicina da Universidade de Lisboa (FMUL), Av. Prof. Egas Moniz, Lisbon, Portugal
| | - Ana Fred
- Department of Bioengineering (DBE), Instituto de Telecomunicações (IT), Instituto Superior Técnico (IST), Lisbon, Portugal
| | - Hugo P da Silva
- Department of Bioengineering (DBE), Instituto de Telecomunicações (IT), Instituto Superior Técnico (IST), Lisbon, Portugal
| |
Collapse
|
10
|
Rosch M, Gutowski T, Baehr M, Eggert J, Gottfried K, Gundler C, Nürnberg S, Langebrake C, Dadkhah A. Development of an immediate release excipient composition for 3D printing via direct powder extrusion in a hospital. Int J Pharm 2023; 643:123218. [PMID: 37467818 DOI: 10.1016/j.ijpharm.2023.123218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 07/07/2023] [Accepted: 07/08/2023] [Indexed: 07/21/2023]
Abstract
3D printing offers the possibility to prepare personalized tablets on demand, making it an intriguing technology for hospital pharmacies. For the implementation of 3D-printed tablets into the digital Closed Loop Medication Management system, the required tablet formulation and development of the manufacturing process as well as the pharmaceutical validation were conducted. The goal of the formulation development was to enable an optimal printing process and rapid dissolution of the printed tablets for the selected model drugs Levodopa/Carbidopa. The 3D printed tablets were prepared by direct powder extrusion. Printability, thermal properties, disintegration, dissolution, physical properties and storage stability were investigated by employing analytical methods such as HPLC-UV, DSC and TGA. The developed formulation shows a high dose accuracy and an immediate drug release for Levodopa. In addition, the tablets exhibit high crushing strength and very low friability. Unfortunately, Carbidopa did not tolerate the printing process. This is the first study to develop an immediate release excipient composition via direct powder extrusion in a hospital pharmacy setting. The developed process is suitable for the implementation in Closed-Loop Medication Management systems in hospital pharmacies and could therefore contribute to medication safety.
Collapse
Affiliation(s)
- Moritz Rosch
- Hospital Pharmacy, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Tobias Gutowski
- Hospital Pharmacy, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Michael Baehr
- Hospital Pharmacy, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Jan Eggert
- Hospital Pharmacy, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Karl Gottfried
- Institute for Applied Medical Informatics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Christopher Gundler
- Institute for Applied Medical Informatics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Sylvia Nürnberg
- Institute for Applied Medical Informatics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Claudia Langebrake
- Hospital Pharmacy, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Department of Stem Cell Transplantation, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Adrin Dadkhah
- Hospital Pharmacy, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Department of Stem Cell Transplantation, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| |
Collapse
|
11
|
van Westrhenen A, Lazeron RHC, van Dijk JP, Leijten FSS, Thijs RD. Multimodal nocturnal seizure detection in children with epilepsy: A prospective, multicenter, long-term, in-home trial. Epilepsia 2023; 64:2137-2152. [PMID: 37195144 DOI: 10.1111/epi.17654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 05/14/2023] [Accepted: 05/15/2023] [Indexed: 05/18/2023]
Abstract
OBJECTIVE There is a pressing need for reliable automated seizure detection in epilepsy care. Performance evidence on ambulatory non-electroencephalography-based seizure detection devices is low, and evidence on their effect on caregiver's stress, sleep, and quality of life (QoL) is still lacking. We aimed to determine the performance of NightWatch, a wearable nocturnal seizure detection device, in children with epilepsy in the family home setting and to assess its impact on caregiver burden. METHODS We conducted a phase 4, multicenter, prospective, video-controlled, in-home NightWatch implementation study (NCT03909984). We included children aged 4-16 years, with ≥1 weekly nocturnal major motor seizure, living at home. We compared a 2-month baseline period with a 2-month NightWatch intervention. The primary outcome was the detection performance of NightWatch for major motor seizures (focal to bilateral or generalized tonic-clonic [TC] seizures, focal to bilateral or generalized tonic seizures lasting >30 s, hyperkinetic seizures, and a remainder category of focal to bilateral or generalized clonic seizures and "TC-like" seizures). Secondary outcomes included caregivers' stress (Caregiver Strain Index [CSI]), sleep (Pittsburgh Quality of Sleep Index), and QoL (EuroQol five-dimension five-level scale). RESULTS We included 53 children (55% male, mean age = 9.7 ± 3.6 years, 68% learning disability) and analyzed 2310 nights (28 173 h), including 552 major motor seizures. Nineteen participants did not experience any episode of interest during the trial. The median detection sensitivity per participant was 100% (range = 46%-100%), and the median individual false alarm rate was .04 per hour (range = 0-.53). Caregiver's stress decreased significantly (mean total CSI score = 8.0 vs. 7.1, p = .032), whereas caregiver's sleep and QoL did not change significantly during the trial. SIGNIFICANCE The NightWatch system demonstrated high sensitivity for detecting nocturnal major motor seizures in children in a family home setting and reduced caregiver stress.
Collapse
Affiliation(s)
- Anouk van Westrhenen
- Stichting Epilepsie Instellingen Nederland (SEIN), Heemstede and Zwolle, the Netherlands
- Department of Neurology and Clinical Neurophysiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Richard H C Lazeron
- Academic Center of Epileptology Kempenhaeghe, Heeze, the Netherlands
- Faculty of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Johannes P van Dijk
- Academic Center of Epileptology Kempenhaeghe, Heeze, the Netherlands
- Faculty of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
- Department of Orthodontics, Ulm University, Ulm, Germany
| | - Frans S S Leijten
- Brain Center, Department of Neurology, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Roland D Thijs
- Stichting Epilepsie Instellingen Nederland (SEIN), Heemstede and Zwolle, the Netherlands
- Department of Neurology and Clinical Neurophysiology, Leiden University Medical Center, Leiden, the Netherlands
- UCL Queen Square Institute of Neurology, London, UK
| |
Collapse
|
12
|
Djemal A, Bouchaala D, Fakhfakh A, Kanoun O. Wearable Electromyography Classification of Epileptic Seizures: A Feasibility Study. Bioengineering (Basel) 2023; 10:703. [PMID: 37370634 DOI: 10.3390/bioengineering10060703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 05/29/2023] [Accepted: 06/07/2023] [Indexed: 06/29/2023] Open
Abstract
Accurate diagnosis and classification of epileptic seizures can greatly support patient treatments. As many epileptic seizures are convulsive and have a motor component, the analysis of muscle activity can provide valuable information for seizure classification. Therefore, this paper present a feasibility study conducted on healthy volunteers, focusing on tracking epileptic seizures movements using surface electromyography signals (sEMG) measured on human limb muscles. For the experimental studies, first, compact wireless sensor nodes were developed for real-time measurement of sEMG on the gastrocnemius, flexor carpi ulnaris, biceps brachii, and quadriceps muscles on the right side and the left side. For the classification of the seizure, a machine learning model has been elaborated. The 16 common sEMG time-domain features were first extracted and examined with respect to discrimination and redundancy. This allowed the features to be classified into irrelevant features, important features, and redundant features. Redundant features were examined with the Big-O notation method and with the average execution time method to select the feature that leads to lower complexity and reduced processing time. The finally selected six features were explored using different machine learning classifiers to compare the resulting classification accuracy. The results show that the artificial neural network (ANN) model with the six features: IEMG, WAMP, MYOP, SE, SKEW, and WL, had the highest classification accuracy (99.95%). A further study confirms that all the chosen eight sensors are necessary to reach this high classification accuracy.
Collapse
Affiliation(s)
- Achraf Djemal
- Measurement and Sensor Technology, Chemnitz University of Technology, Reichenhainer Straße 70, 09126 Chemnitz, Germany
- Laboratory of Signals, Systems, Artificial Intelligence and Networks, Digital Research Centre of Sfax, National School of Electronics and Telecommunications of Sfax, Technopole of Sfax, Ons City 3021, Tunisia
| | - Dhouha Bouchaala
- National Engineering School of Sfax, University of Sfax, Route de la Soukra km 4, Sfax 3038, Tunisia
| | - Ahmed Fakhfakh
- Laboratory of Signals, Systems, Artificial Intelligence and Networks, Digital Research Centre of Sfax, National School of Electronics and Telecommunications of Sfax, Technopole of Sfax, Ons City 3021, Tunisia
| | - Olfa Kanoun
- Measurement and Sensor Technology, Chemnitz University of Technology, Reichenhainer Straße 70, 09126 Chemnitz, Germany
| |
Collapse
|
13
|
Nouboue C, Selfi S, Diab E, Chen S, Périn B, Szurhaj W. Assessment of an under-mattress sensor as a seizure detection tool in an adult epilepsy monitoring unit. Seizure 2023; 105:17-21. [PMID: 36652886 DOI: 10.1016/j.seizure.2023.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 01/06/2023] [Accepted: 01/08/2023] [Indexed: 01/15/2023] Open
Abstract
OBJECTIVE Because of SUDEP (Sudden and unexpected death in epilepsy) and other direct consequences of generalized tonic-clonic seizures, the use of efficient seizure detection tool may be helpful for patients, relatives and caregivers. We aimed to evaluate an under-mattress detection tool (EMFIT®) in real-life hospital conditions, in particular its sensitivity and false alarm rate (FAR), as well as its impact on patient care. METHODS We carried out a retrospective study on a cohort of patients with epilepsy admitted between September 2017 and June 2021 to Amiens University Hospital for a video-EEG of at least 24 h, during which at least one epileptic seizure was recorded. All video-EEGs records were analyzed visually in order to assess the sensitivity of the under-mattress tool (triggering of the alarm) and to classify the seizure type (convulsive/non convulsive). We also considered whether nurses intervened during the seizure, and the time of their intervention if applicable. An additional prospective survey was conducted over 272 days to analyze the FAR of the tool. RESULTS A total of 220 seizures were included in the study, from 55 patients, including 23 convulsive seizures from 15 patients and 197 non-convulsive seizures. Sensitivity for convulsive seizure detection was 69.6%. As expected, none of the non-convulsive seizures was detected. The false alarm rate was 0.007/day. Median trigger time was 74 s, decreasing to 5 s for generalized tonic-clonic seizure. The frequency of nurses' intervention during convulsive seizures was significantly greater in case of the alarm triggering (100% vs 57%, p<0.02). SIGNIFICANCE These results suggest that EMFIT® sensor is able to detect convulsive seizures with good sensitivity and low FAR, and allows caregivers to intervene more often in the event of a nocturnal seizure. This would be an interesting complementary tool to better secure the patients with epilepsy during hospitalization or at home.
Collapse
Affiliation(s)
- Carole Nouboue
- Clinical Neurophysiology Department, CHU Amiens, France; UR 7516, CHIMERE, University of Picardie Jules Verne, Amiens, France
| | - Sarah Selfi
- Clinical Neurophysiology Department, CHU Amiens, France
| | - Eva Diab
- Clinical Neurophysiology Department, CHU Amiens, France; UR 7516, CHIMERE, University of Picardie Jules Verne, Amiens, France
| | - Simone Chen
- Clinical Neurophysiology Department, CHU Amiens, France
| | | | - William Szurhaj
- Clinical Neurophysiology Department, CHU Amiens, France; UR 7516, CHIMERE, University of Picardie Jules Verne, Amiens, France.
| |
Collapse
|
14
|
Kalitzin S. Adaptive Remote Sensing Paradigm for Real-Time Alerting of Convulsive Epileptic Seizures. SENSORS (BASEL, SWITZERLAND) 2023; 23:968. [PMID: 36679763 PMCID: PMC9862933 DOI: 10.3390/s23020968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 12/30/2022] [Accepted: 01/12/2023] [Indexed: 06/17/2023]
Abstract
Epilepsy is a debilitating neurological condition characterized by intermittent paroxysmal states called fits or seizures. Especially, the major motor seizures of a convulsive nature, such as tonic-clonic seizures, can cause aggravating consequences. Timely alerting for these convulsive epileptic states can therefore prevent numerous complications, during, or following the fit. Based on our previous research, a non-contact method using automated video camera observation and optical flow analysis underwent field trials in clinical settings. Here, we propose a novel adaptive learning paradigm for optimization of the seizure detection algorithm in each individual application. The main objective of the study was to minimize the false detection rate while avoiding undetected seizures. The system continuously updated detection parameters retrospectively using the data from the generated alerts. The system can be used under supervision or, alternatively, through autonomous validation of the alerts. In the latter case, the system achieved self-adaptive, unsupervised learning functionality. The method showed improvement of the detector performance due to the learning algorithm. This functionality provided a personalized seizure alerting device that adapted to the specific patient and environment. The system can operate in a fully automated mode, still allowing human observer to monitor and override the decision process while the algorithm provides suggestions as an expert system.
Collapse
Affiliation(s)
- Stiliyan Kalitzin
- Stichting Epilepsie Instellingen Nederland (SEIN), 2103 SW Heemstede, The Netherlands
| |
Collapse
|
15
|
Gu B, Adeli H. Toward automated prediction of sudden unexpected death in epilepsy. Rev Neurosci 2022; 33:877-887. [PMID: 35619127 DOI: 10.1515/revneuro-2022-0024] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Accepted: 04/19/2022] [Indexed: 12/14/2022]
Abstract
Sudden unexpected death in epilepsy (SUDEP) is a devastating yet overlooked complication of epilepsy. The rare and complex nature of SUDEP makes it challenging to study. No prediction or prevention of SUDEP is currently available in a clinical setting. In the past decade, significant advances have been made in our knowledge of the pathophysiologic cascades that lead to SUDEP. In particular, studies of brain, heart, and respiratory functions in both human patients at the epilepsy monitoring unit and animal models during fatal seizures provide critical information to integrate computational tools for SUDEP prediction. The rapid advances in automated seizure detection and prediction algorithms provide a fundamental framework for their adaption in predicting SUDEP. If a SUDEP can be predicted, then there will be a potential for medical intervention to be administered, either by their caregivers or via an implanted device automatically delivering electrical stimulation or medication, and finally save lives from fatal seizures. This article presents recent developments of SUDEP studies focusing on the pathophysiologic basis of SUDEP and computational implications of machine learning techniques that can be adapted and extended for SUDEP prediction. This article also discusses some novel ideas for SUDEP prediction and rescue including principal component analysis and closed-loop intervention.
Collapse
Affiliation(s)
- Bin Gu
- Department of Neuroscience, Ohio State University, Columbus, OH 43210, USA
| | - Hojjat Adeli
- Department of Neuroscience, Ohio State University, Columbus, OH 43210, USA.,Department of Biomedical Informatics, Ohio State University, Columbus, OH 43210, USA
| |
Collapse
|
16
|
Mecarelli O, Di Gennaro G, Vigevano F. Unmet needs and perspectives in management of drug resistant focal epilepsy: An Italian study. Epilepsy Behav 2022; 137:108950. [PMID: 36347069 DOI: 10.1016/j.yebeh.2022.108950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 10/04/2022] [Accepted: 10/07/2022] [Indexed: 11/07/2022]
Abstract
This study aimed to evaluate the consensus level between a representative group of Italian neurologists and people with Drug-Resistant Epilepsy (DRE) regarding a series of statements about different aspects involved in the management of epilepsy to identify the unmet needs of the People with Epilepsy (PwE) and the future perspectives for the management of this disease. This observational study was conducted using a classic Delphi technique. A 19-statement questionnaire was administered anonymously through an online platform to a panel of expert clinicians and a panel of PwE, analyzing three main topics of interest: drug resistance, access to care, and PwE's experience. The consensus was achieved on 8 of the 19 statements administered to the panel of medical experts and on 4 of the 14 submitted to the panel of PwE, particularly on the definition of DRE and its consequences on treatment, Quality of Life (QoL), and autonomy of PwE. Most of the items, however, did not reach a consensus and highlighted the lack of a shared univocal view on some topics, such as accessibility to care throughout the country and the role of emerging tools such as telemedicine, narrative medicine, and digital devices. In many cases, the two panels expressed different views on the statements. The results outlined many fields of possible intervention, such as the need for educational initiatives targeted at physicians and PwE - for example, regarding telemedicine, digital devices, and narrative medicine - as well as the spread of better knowledge about epilepsy among the general population, in order to reduce epilepsy stigma. Institutions, moreover, could take a cue from this survey to develop facilities aimed at enhancing PwE's autonomy and promoting more equal access to care throughout the country.
Collapse
Affiliation(s)
- Oriano Mecarelli
- Department of Human Neurosciences, Sapienza University, Rome and Past President of LICE, Italian League Against Epilepsy, Rome, Italy.
| | | | - Federico Vigevano
- Department of Neuroscience, Bambino Gesù Children's Hospital, IRCCS, Full Member of European Reference Network EpiCARE, Rome, Italy.
| |
Collapse
|
17
|
Remvig LS, Duun-Henriksen J, Fürbass F, Hartmann M, Viana PF, Kappel Overby AM, Weisdorf S, Richardson MP, Beniczky S, Kjaer TW. Detecting temporal lobe seizures in ultra long-term subcutaneous EEG using algorithm-based data reduction. Clin Neurophysiol 2022; 142:86-93. [PMID: 35987094 DOI: 10.1016/j.clinph.2022.07.504] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 06/10/2022] [Accepted: 07/03/2022] [Indexed: 11/03/2022]
Abstract
OBJECTIVE Ultra long-term monitoring with subcutaneous EEG (sqEEG) offers objective outpatient recording of electrographic seizures as an alternative to self-reported epileptic seizure diaries. This methodology requires an algorithm-based automatic seizure detection to indicate periods of potential seizure activity to reduce the time spent on visual review. The objective of this study was to evaluate the performance of a sqEEG-based automatic seizure detection algorithm. METHODS A multicenter cohort of subjects using sqEEG were analyzed, including nine people with epilepsy (PWE) and 12 healthy subjects, recording a total of 965 days. The automatic seizure detections of a deep-neural-network algorithm were compared to annotations from three human experts. RESULTS Data reduction ratios were 99.6% in PWE and 99.9% in the control group. The cross-PWE sensitivity was 86% (median 80%, range 69-100% when PWE were evaluated individually), and the corresponding median false detection rate was 2.4 detections per 24 hours (range: 2.0-13.0). CONCLUSIONS Our findings demonstrated that step one in a sqEEG-based semi-automatic seizure detection/review process can be performed with high sensitivity and clinically applicable specificity. SIGNIFICANCE Ultra long-term sqEEG bears the potential of improving objective seizure quantification.
Collapse
Affiliation(s)
- Line S Remvig
- UNEEG Medical A/S, Borupvang 2, DK-3450 Allerød, Denmark.
| | | | - Franz Fürbass
- Center for Health & Bioresources, AIT Austrian Institute of Technology GmbH, Giefinggasse 4, 1210 Vienna, Austria
| | - Manfred Hartmann
- Center for Health & Bioresources, AIT Austrian Institute of Technology GmbH, Giefinggasse 4, 1210 Vienna, Austria
| | - Pedro F Viana
- Department of Basic & Clinical Neuroscience, Maurice Wohl Clinical Neuroscience Institute, King's College London, Denmark Hill, London, UK; Faculty of Medicine, University of Lisbon, Av. Prof. Egas Moniz MB, 1649-028 Lisboa, Portugal
| | | | - Sigge Weisdorf
- Center of Neurophysiology, Department Neurology, Zealand University Hospital, Sygehusvej 10, DK-4000 Roskilde, Denmark
| | - Mark P Richardson
- Department of Basic & Clinical Neuroscience, Maurice Wohl Clinical Neuroscience Institute, King's College London, Denmark Hill, London, UK
| | - Sándor Beniczky
- The Danish Epilepsy Centre, Filadelfia, Kolonivej 1, 4293 Dianalund, Denmark; Aarhus University and Aarhus University Hospital, Palle Juul-Jensens Blvd 99, DK-8200 Aarhus, Denmark
| | - Troels W Kjaer
- Center of Neurophysiology, Department Neurology, Zealand University Hospital, Sygehusvej 10, DK-4000 Roskilde, Denmark; Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3b, DK.2200 Copenhagen, Denmark
| |
Collapse
|
18
|
Esmaeili B, Vieluf S, Dworetzky BA, Reinsberger C. The Potential of Wearable Devices and Mobile Health Applications in the Evaluation and Treatment of Epilepsy. Neurol Clin 2022; 40:729-739. [DOI: 10.1016/j.ncl.2022.03.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
19
|
Devi S, Guha K, Jakšić O, Baishnab KL, Jakšić Z. Optimized Design of a Self-Biased Amplifier for Seizure Detection Supplied by Piezoelectric Nanogenerator: Metaheuristic Algorithms versus ANN-Assisted Goal Attainment Method. MICROMACHINES 2022; 13:mi13071104. [PMID: 35888921 PMCID: PMC9324449 DOI: 10.3390/mi13071104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2022] [Revised: 07/11/2022] [Accepted: 07/12/2022] [Indexed: 02/04/2023]
Abstract
This work is dedicated to parameter optimization for a self-biased amplifier to be used in preamplifiers for the diagnosis of seizures in neuro-diseases such as epilepsy. For the sake of maximum compactness, which is obligatory for all implantable devices, power is to be supplied by a piezoelectric nanogenerator (PENG). Several meta-heuristic optimization algorithms and an ANN (artificial neural network)-assisted goal attainment method were applied to the circuit, aiming to provide us with the set of optimal design parameters which ensure the minimal overall area of the preamplifier. These parameters are the slew rate, load capacitor, gain–bandwidth product, maximal input voltage, minimal input voltage, input voltage, reference voltage, and dissipation power. The results are re-evaluated and compared in the Cadence 180 nm SCL environment. It has been observed that, among the metaheuristic algorithms, the whale optimization technique reached the best values at low computational cost, decreased complexity, and the highest convergence speed. However, all metaheuristic algorithms were outperformed by the ANN-assisted goal attainment method, which produced a roughly 50% smaller overall area of the preamplifier. All the techniques described here are applicable to the design and optimization of wearable or implantable circuits.
Collapse
Affiliation(s)
- Swagata Devi
- Department of Electronics and Communication Engineering, National Institute of Technology Silchar, Silchar 788010, Assam, India; (S.D.); (K.G.); (K.L.B.)
| | - Koushik Guha
- Department of Electronics and Communication Engineering, National Institute of Technology Silchar, Silchar 788010, Assam, India; (S.D.); (K.G.); (K.L.B.)
| | - Olga Jakšić
- Center of Microelectronic Technologies, Institute of Chemistry, Technology and Metallurgy—National Institute of the Republic of Serbia, University of Belgrade, Njegoševa 12, 11000 Belgrade, Serbia;
- Correspondence:
| | - Krishna Lal Baishnab
- Department of Electronics and Communication Engineering, National Institute of Technology Silchar, Silchar 788010, Assam, India; (S.D.); (K.G.); (K.L.B.)
| | - Zoran Jakšić
- Center of Microelectronic Technologies, Institute of Chemistry, Technology and Metallurgy—National Institute of the Republic of Serbia, University of Belgrade, Njegoševa 12, 11000 Belgrade, Serbia;
| |
Collapse
|
20
|
Ingolfsson TM, Cossettini A, Benatti S, Benini L. Energy-Efficient Tree-Based EEG Artifact Detection. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:3723-3728. [PMID: 36086434 DOI: 10.1109/embc48229.2022.9871413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In the context of epilepsy monitoring, EEG artifacts are often mistaken for seizures due to their morphological simi-larity in both amplitude and frequency, making seizure detection systems susceptible to higher false alarm rates. In this work we present the implementation of an artifact detection algorithm based on a minimal number of EEG channels on a parallel ultra-low-power (PULP) embedded platform. The analyses are based on the TUH EEG Artifact Corpus dataset and focus on the temporal electrodes. First, we extract optimal feature models in the frequency domain using an automated machine learning framework, achieving a 93.95% accuracy, with a 0.838 F1 score for a 4 temporal EEG channel setup. The achieved accuracy levels surpass state-of-the-art by nearly 20%. Then, these algorithms are parallelized and optimized for a PULP platform, achieving a 5.21x improvement of energy-efficient compared to state-of-the-art low-power implementations of artifact detection frameworks. Combining this model with a low-power seizure detection algorithm would allow for 300h of continuous monitoring on a 300 mAh battery in a wearable form factor and power budget. These results pave the way for implementing affordable, wearable, long-term epilepsy monitoring solutions with low false-positive rates and high sensitivity, meeting both patients' and caregivers' requirements. Clinical relevance- The proposed EEG artifact detection framework can be employed on wearable EEG recording devices, in combination with EEG-based epilepsy detection algorithms, for improved robustness in epileptic seizure detection scenarios.
Collapse
|
21
|
Guermandi M, Cossettini A, Benatti S, Benini L. A Wireless System for EEG Acquisition and Processing in an Earbud Form Factor with 600 Hours Battery Lifetime. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:3139-3145. [PMID: 36086587 DOI: 10.1109/embc48229.2022.9871874] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In recent years, in-ear electroencephalography (EEG) was demonstrated to record signals of similar quality compared to standard scalp-based EEG, and clinical applications of objective hearing threshold estimations have been reported. Existing devices, however, still lack important features. In fact, most of the available solutions are based on wet electrodes, require to be connected to external acquisition platforms, or do not offer on-board processing capabilities. Here we overcome all these limitations, presenting an ear-EEG system based on dry electrodes that includes all the acquisition, processing, and connectivity electronics directly in the ear bud. The earpiece is equipped with an ultra-low power analog front-end for analog-to-digital conversion, a low-power MEMS microphone, a low-power inertial measurement unit, and an ARM Cortex-M4 based microcontroller enabling on-board processing and Bluetooth Low Energy connectivity. The system can stream raw EEG data or perform data processing directly in-ear. We test the device by analysing its capability to detect brain response to external auditory stimuli, achieving 4 and 1.3 mW power consumption for data streaming or on board processing, respectively. The latter allows for 600 hours operation on a PR44 zinc-air battery. To the best of our knowledge, this is the first wireless and fully self-contained ear-EEG system performing on-board processing, all embedded in a single earbud. Clinical relevance- The proposed ear-EEG system can be employed for diagnostic tasks such as objective hearing threshold estimations, outside of clinical settings, thereby enabling it as a point-of-care solution. The long battery lifetime is also suitable for a continuous monitoring scenario.
Collapse
|
22
|
Sivathamboo S, Nhu D, Piccenna L, Yang A, Antonic-Baker A, Vishwanath S, Todaro M, Yap LW, Kuhlmann L, Cheng W, O'Brien TJ, Lannin NA, Kwan P. Preferences and User Experiences of Wearable Devices in Epilepsy: A Systematic Review and Mixed-Methods Synthesis. Neurology 2022; 99:e1380-e1392. [PMID: 35705497 DOI: 10.1212/wnl.0000000000200794] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Accepted: 04/12/2022] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND AND OBJECTIVES To examine the preferences and user experiences of people with epilepsy and caregivers regarding automated wearable seizure detection devices. METHODS We performed a mixed-methods systematic review. We searched electronic databases for original peer-reviewed publications between January 1, 2000, and May 26, 2021. Key search terms included "epilepsy", "seizure", "wearable", and "non-invasive". We performed a descriptive and a qualitative thematic analysis of the studies included according to the technology acceptance model. Full texts of the discussion sections were further analyzed to identify word frequency and word mapping. RESULTS Twenty-two observational studies were identified. Collectively, they comprised responses from 3299 participants including patients with epilepsy, caregivers and healthcare workers. Sixteen studies examined user preferences, five examined user experiences, and one examined both experiences and preferences. Important preferences for wearables included improving care, cost, accuracy, and design. Patients desired real-time detection with a latency of ≤15 minutes from seizure occurrence, along with high sensitivity (≥90%) and low false-alarm rates. Device related costs were a major factor for device acceptance, where device costs of <$300 USD and a monthly subscription fee of <$20 USD were preferred. Despite being a major driver of wearable-based technologies, sudden unexpected death in epilepsy (SUDEP) was rarely discussed. Among studies evaluating user experiences, there was a greater acceptance towards wristwatches. Thematic coding analysis showed that attitudes towards device use, and perceived usefulness were reported consistently. Word mapping identified 'specificity', 'cost', and 'battery' as key single terms, and 'battery life', 'insurance coverage', 'prediction/detection quality', and the effect of devices on 'daily life' as key bigrams. DISCUSSION User acceptance of wearable technology for seizure detection was strongly influenced by accuracy, design, comfort, and cost. Our findings emphasise the need for standardised and validated tools to comprehensively examine preferences and user experiences of wearable devices in this population, using the themes identified in this study. Greater efforts to incorporate perspectives and user experiences in developing wearables for seizure detection, particularly in community-based settings are needed. PROSPERO REGISTRATION CRD42020193565.
Collapse
Affiliation(s)
- Shobi Sivathamboo
- Department of Neuroscience, Central Clinical School, Monash University, Melbourne, 3004, Victoria, Australia.,Department of Neurology, Alfred Health, Melbourne, 3004, Victoria, Australia.,Department of Medicine (The Royal Melbourne Hospital), The University of Melbourne, 3000, Victoria, Australia.,Department of Neurology, The Royal Melbourne Hospital, Melbourne, 3000, Victoria, Australi
| | - Duong Nhu
- Department of Data Science and AI, Faculty of Information Technology, Monash University, Clayton, 3800, Victoria, Australia
| | - Loretta Piccenna
- Department of Neuroscience, Central Clinical School, Monash University, Melbourne, 3004, Victoria, Australia.,Department of Neurology, Alfred Health, Melbourne, 3004, Victoria, Australia.,Department of Medicine (The Royal Melbourne Hospital), The University of Melbourne, 3000, Victoria, Australia
| | - Anthony Yang
- Department of Neuroscience, Central Clinical School, Monash University, Melbourne, 3004, Victoria, Australia.,Department of Neurology, Alfred Health, Melbourne, 3004, Victoria, Australia.,Department of Medicine (The Royal Melbourne Hospital), The University of Melbourne, 3000, Victoria, Australia
| | - Ana Antonic-Baker
- Department of Neuroscience, Central Clinical School, Monash University, Melbourne, 3004, Victoria, Australia
| | - Swarna Vishwanath
- Department of Neuroscience, Central Clinical School, Monash University, Melbourne, 3004, Victoria, Australia
| | - Marian Todaro
- Department of Neuroscience, Central Clinical School, Monash University, Melbourne, 3004, Victoria, Australia.,Department of Neurology, Alfred Health, Melbourne, 3004, Victoria, Australia.,Department of Medicine (The Royal Melbourne Hospital), The University of Melbourne, 3000, Victoria, Australia.,Department of Neurology, The Royal Melbourne Hospital, Melbourne, 3000, Victoria, Australi
| | - Lim Wei Yap
- Department of Chemical and Biological Engineering, Monash University, Clayton, 3800, Victoria, Australi
| | - Levin Kuhlmann
- Department of Data Science and AI, Faculty of Information Technology, Monash University, Clayton, 3800, Victoria, Australia
| | - Wenlong Cheng
- Department of Chemical and Biological Engineering, Monash University, Clayton, 3800, Victoria, Australi
| | - Terence J O'Brien
- Department of Neuroscience, Central Clinical School, Monash University, Melbourne, 3004, Victoria, Australia.,Department of Neurology, Alfred Health, Melbourne, 3004, Victoria, Australia.,Department of Medicine (The Royal Melbourne Hospital), The University of Melbourne, 3000, Victoria, Australia.,Department of Neurology, The Royal Melbourne Hospital, Melbourne, 3000, Victoria, Australi
| | - Natasha A Lannin
- Department of Neuroscience, Central Clinical School, Monash University, Melbourne, 3004, Victoria, Australia.,Alfred Health (Allied Health Directorate), Melbourne, 3004, Victoria, Australia
| | - Patrick Kwan
- Department of Neuroscience, Central Clinical School, Monash University, Melbourne, 3004, Victoria, Australia .,Department of Neurology, Alfred Health, Melbourne, 3004, Victoria, Australia.,Department of Medicine (The Royal Melbourne Hospital), The University of Melbourne, 3000, Victoria, Australia.,Department of Neurology, The Royal Melbourne Hospital, Melbourne, 3000, Victoria, Australi
| |
Collapse
|
23
|
Intra- and Inter-Subject Perspectives on the Detection of Focal Onset Motor Seizures in Epilepsy Patients. SENSORS 2022; 22:s22093318. [PMID: 35591007 PMCID: PMC9105312 DOI: 10.3390/s22093318] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 04/19/2022] [Accepted: 04/22/2022] [Indexed: 01/15/2023]
Abstract
Focal onset epileptic seizures are highly heterogeneous in their clinical manifestations, and a robust seizure detection across patient cohorts has to date not been achieved. Here, we assess and discuss the potential of supervised machine learning models for the detection of focal onset motor seizures by means of a wrist-worn wearable device, both in a personalized context as well as across patients. Wearable data were recorded in-hospital from patients with epilepsy at two epilepsy centers. Accelerometry, electrodermal activity, and blood volume pulse data were processed and features for each of the biosignal modalities were calculated. Following a leave-one-out approach, a gradient tree boosting machine learning model was optimized and tested in an intra-subject and inter-subject evaluation. In total, 20 seizures from 9 patients were included and we report sensitivities of 67% to 100% and false alarm rates of down to 0.85 per 24 h in the individualized assessment. Conversely, for an inter-subject seizure detection methodology tested on an out-of-sample data set, an optimized model could only achieve a sensitivity of 75% at a false alarm rate of 13.4 per 24 h. We demonstrate that robustly detecting focal onset motor seizures with tonic or clonic movements from wearable data may be possible for individuals, depending on specific seizure manifestations.
Collapse
|
24
|
EEG Oscillatory Power and Complexity for Epileptic Seizure Detection. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12094181] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Monitoring patients at risk of epileptic seizure is critical for optimal treatment and ensuing the reduction of seizure risk and complications. In general, seizure detection is done manually in hospitals and involves time-consuming visual inspection and interpretation by experts of electroencephalography (EEG) recordings. The purpose of this study is to investigate the pertinence of band-limited spectral power and signal complexity in order to discriminate between seizure and seizure-free EEG brain activity. The signal complexity and spectral power are evaluated in five frequency intervals, namely, the delta, theta, alpha, beta, and gamma bands, to be used as EEG signal feature representation. Classification of seizure and seizure-free data was performed by prevalent potent classifiers. Substantial comparative performance evaluation experiments were performed on a large EEG data record of 341 patients in the Temple University Hospital EEG seizure database. Based on statistically validated criteria, results show the efficiency of band-limited spectral power and signal complexity when using random forest and gradient-boosting decision tree classifiers (95% of the area under the curve (AUC) and 91% for both F-measure and accuracy). These results support the use of these automatic classification schemes to assist the practicing neurologist interpret EEG records more accurately and without tedious visual inspection.
Collapse
|
25
|
Digital Health Technologies in Pediatric Trials. Ther Innov Regul Sci 2022; 56:929-933. [PMID: 35344202 DOI: 10.1007/s43441-021-00374-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 12/27/2021] [Indexed: 10/18/2022]
Abstract
BACKGROUND Advances in the miniaturization of sensors and other technologies provide opportunities to collect physiological and/or functional data directly from patients participating in clinical trials. The use of such technologies in children is particularly promising. Objective, quantifiable measurements made by these technologies, often on a continuous or frequent basis, may provide more robust data than the episodic reports from caregivers that are used in traditional pediatric trials. METHODS We reviewed the pros and cons of these technologies for use in a variety of pediatric diseases, including seizure and neuromuscular disorders, cardiorespiratory diseases, and metabolic disorders. RESULTS Correlation between sensor measurements and patient observations or traditional clinical measurements varied depending on the disease being evaluated. There was a notable dearth of reports on the use of digital health technology in pediatric patients. Given the range of sensors and measurements that can be made by DHTs, selection of the design, metrics and types of sensors best suited to disease evaluation presents challenges for adoption of these technologies in clinical trials. CONCLUSION Traditional measurements of drug effects are often deficient, particularly in the evaluation of infants and young children. The opportunity to make objective, frequent measurements may increase our power to detect and quantify responses to therapy in these populations. Further research and evaluation are needed to realize the full scientific potential of remote monitoring in pediatric clinical trials.
Collapse
|
26
|
Milne-Ives M, Shankar R, McLean B, Duun-Henriksen J, Blaabjerg L, Meinert E. Remote Electroencephalography Monitoring of Epilepsy in Adults: Protocol for a Scoping Review. JMIR Res Protoc 2022; 11:e33812. [PMID: 35212630 PMCID: PMC8917432 DOI: 10.2196/33812] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 12/07/2021] [Accepted: 12/08/2021] [Indexed: 11/17/2022] Open
Abstract
Background Electroencephalography (EEG) monitoring is a key tool in diagnosing and determining treatment for people with epilepsy; however, obtaining sufficient high-quality data can be a time-consuming, costly, and inconvenient process for patients and health care providers. Remote EEG monitoring has the potential to improve patient experience, data quality, and accessibility for people with intellectual or developmental disabilities. Objective The purpose of this scoping review is to provide an overview of the current research evidence and knowledge gaps regarding the use of remote EEG monitoring interventions for adults with epilepsy. Methods The PRISMA-ScR (Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews) and Population, Intervention, Comparator, Outcome, and Study (PICOS) frameworks will be used to structure the review. Searches will be conducted in 6 databases (PubMed, MEDLINE, Embase, CINAHL, Web of Science, and ClinicalTrials.gov) for articles published in English that evaluate at least one out-of-hospital EEG monitoring intervention or device for adults with epilepsy. A descriptive analysis will be conducted to summarize the results; key themes and gaps in the literature will be discussed. Results Results will be included in the scoping review, which will be submitted for publication by April 2022. Conclusions This scoping review will summarize the state of the field of remote EEG monitoring interventions for adults with epilepsy and provide an overview of the strengths, weaknesses, and gaps in the research. International Registered Report Identifier (IRRID) PRR1-10.2196/33812
Collapse
Affiliation(s)
- Madison Milne-Ives
- Centre for Health Technology, University of Plymouth, Plymouth, United Kingdom
| | - Rohit Shankar
- Peninsula Medical School, Faculty of Health, University of Plymouth, Plymouth, United Kingdom.,Cornwall Partnership NHS Foundation Trust, Bodmin, United Kingdom
| | - Brendan McLean
- Royal Cornwall Hospitals NHS Trust, Truro, United Kingdom
| | - Jonas Duun-Henriksen
- UNEEG medical A/S, Alleroed, Denmark.,Department of Basic & Clinical Neuroscience, King's College London, London, United Kingdom
| | | | - Edward Meinert
- Centre for Health Technology, University of Plymouth, Plymouth, United Kingdom.,Harvard T.H. Chan School of Public Health, Harvard University, Boston, MA, United States.,Department of Primary Care and Public Health, School of Public Health, Imperial College London, London, United Kingdom
| |
Collapse
|
27
|
Westrhenen A, Wijnen BF, Thijs RD. Parental preferences for seizure detection devices: a discrete choice experiment. Epilepsia 2022; 63:1152-1163. [PMID: 35184284 PMCID: PMC9314803 DOI: 10.1111/epi.17202] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Revised: 02/16/2022] [Accepted: 02/16/2022] [Indexed: 11/28/2022]
Abstract
Objective Previous studies identified essential user preferences for seizure detection devices (SDDs), without addressing their relative strength. We performed a discrete choice experiment (DCE) to quantify attributes' strength, and to identify the determinants of user SDD preferences. Methods We designed an online questionnaire targeting parents of children with epilepsy to define the optimal balance between SDD sensitivity and positive predictive value (PPV) while accounting for individual seizure frequency. We selected five DCE attributes from a recent study. Using a Bayesian design, we constructed 11 unique choice tasks and analyzed these using a mixed multinomial logit model. Results One hundred parents responded to the online questionnaire link; 49 completed all tasks, whereas 28 completed the questions, but not the DCE. Most parents preferred a relatively high sensitivity (80%–90%) over a high PPV (>50%). The preferred sensitivity‐to‐PPV ratio correlated with seizure frequency (r = −.32), with a preference for relative high sensitivity and low PPV among those with relative low seizure frequency (p = .04). All DCE attributes significantly impacted parental choices. Parents expressed preferences for consulting a neurologist before device use, personally training the device's algorithm, interaction with their child via audio and video, alarms for all seizure types, and an interface detailing measurements during an alarm. Preferences varied between subgroups (learning disability or not, SDD experience, relative low vs. high seizure frequency based on the population median). Significance Various attributes impact parental SDD preferences and may explain why preferences vary among users. Tailored approaches may help to meet the contrasting needs among SDD users.
Collapse
Affiliation(s)
- Anouk Westrhenen
- Stichting Epilepsie Instellingen Nederland (SEIN) Heemstede PO Box 540 2130 AM Hoofddorp The Netherlands
- Department of Neurology Leiden University Medical Center (LUMC) Albinusdreef 2 2333 ZA Leiden The Netherlands
| | - Ben F.M. Wijnen
- Trimbos Instituut Da Costakade 45 3521 VS Utrecht The Netherlands
- Department of Clinical Epidemiology and Medical Technology Assessment Maastricht University Medical Center Maastricht Netherlands
| | - Roland D. Thijs
- Stichting Epilepsie Instellingen Nederland (SEIN) Heemstede PO Box 540 2130 AM Hoofddorp The Netherlands
- Department of Neurology Leiden University Medical Center (LUMC) Albinusdreef 2 2333 ZA Leiden The Netherlands
- UCL Queen Square Institute of Neurology 23 Queen Square London WC1N United Kingdom
| |
Collapse
|
28
|
Moss A, Moss E, Moss R, Moss L, Chiang S, Crino P. A Patient Perspective on Seizure Detection and Forecasting. Front Neurol 2022; 13:779551. [PMID: 35222243 PMCID: PMC8874203 DOI: 10.3389/fneur.2022.779551] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Accepted: 01/20/2022] [Indexed: 11/24/2022] Open
Affiliation(s)
- Aria Moss
- Northern Virginia Community College, Alexandria, VA, United States
- *Correspondence: Aria Moss
| | - Evan Moss
- W. T. Woodson High School, Fairfax, VA, United States
| | - Robert Moss
- Seizure Tracker, LLC, Springfield, VA, United States
| | - Lisa Moss
- Seizure Tracker, LLC, Springfield, VA, United States
- TSC Alliance, Silver Spring, MD, United States
| | - Sharon Chiang
- Department of Neurology and Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, CA, United States
| | - Peter Crino
- Department of Neurology, University of Maryland School of Medicine, Baltimore, MD, United States
| |
Collapse
|
29
|
Pathmanathan J, Kjaer TW, Cole AJ, Delanty N, Surges R, Duun-Henriksen J. Expert Perspective: Who May Benefit Most From the New Ultra Long-Term Subcutaneous EEG Monitoring? Front Neurol 2022; 12:817733. [PMID: 35126304 PMCID: PMC8810530 DOI: 10.3389/fneur.2021.817733] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Accepted: 12/23/2021] [Indexed: 12/21/2022] Open
Abstract
Today's modalities for short-term monitoring of EEG are primarily meant for supporting clinical diagnosis of epilepsy or classifying seizures and interictal epileptiform discharges while long-term EEG adds the value of differential diagnosis investigation or pre-surgical evaluation. However, longitudinal epilepsy care relies on patient diaries, which is known to be unreliable for most patients and especially those with focal impaired awareness or nocturnal seizures. The subcutaneous ultra long-term EEG (ULT-EEG) systems alleviate those issue by enabling objective, continuous EEG monitoring for days, weeks, months, or years. Albeit a great advance in continuous EEG over extended periods, it comes with the caveat of limited spatial resolution of two channels. Therefore, the new subcutaneous EEG modality may be especially suited for a selected group of patients. We convened a panel of experienced epileptologists to consider the utility of a subcutaneous, two-channel ULT-EEG device with the goal of developing a consensus-based expert recommendation on selecting the optimal patient types for this investigative technique. The ideal patients to select for this type of monitoring would have focal impaired awareness seizures without predominant motor features and seizures with medium to high voltage patterns. As this technology matures and we learn more about its limitations and benefits we might find a wider array of use case scenarios as it is believed that the benefits for many patients are most likely to outweigh the risks and cost.
Collapse
Affiliation(s)
- Jay Pathmanathan
- Department of Neurology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States
| | - Troels W. Kjaer
- Department of Neurology, Center of Neurophysiology, Zealand University Hospital, Roskilde, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Andrew J. Cole
- Massachusetts General Hospital and Harvard Medical School, Boston, MA, United States
| | - Norman Delanty
- Department of Neurology, Beaumont Hospital, Dublin, Ireland
- FutureNeuro Research Centre, Dublin, Ireland
- School of Pharmacy and Biomolecular Sciences, Royal College of Surgeons in Ireland, Dublin, Ireland
| | - Rainer Surges
- Department of Epileptology, University Hospital Bonn, Bonn, Germany
| | | |
Collapse
|
30
|
Kjaer TW, Remvig LS, Helge AW, Duun-Henriksen J. The Individual Ictal Fingerprint: Combining Movement Measures With Ultra Long-Term Subcutaneous EEG in People With Epilepsy. Front Neurol 2022; 12:718329. [PMID: 35002910 PMCID: PMC8733463 DOI: 10.3389/fneur.2021.718329] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Accepted: 12/06/2021] [Indexed: 11/13/2022] Open
Abstract
Background: Epileptic seizures are caused by abnormal brain wave hypersynchronization leading to a range of signs and symptoms. Tools for detecting seizures in everyday life typically focus on cardiac rhythm, electrodermal activity, or movement (EMG, accelerometry); however, these modalities are not very effective for non-motor seizures. Ultra long-term subcutaneous EEG-devices can detect the electrographic changes that do not depend on clinical changes. Nonetheless, this also means that it is not possible to assess whether a seizure is clinical or subclinical based on an EEG signal alone. Therefore, we combine EEG and movement-related modalities in this work. We focus on whether it is possible to define an individual “multimodal ictal fingerprint” which can be exploited in different epilepsy management purposes. Methods: This study used ultra long-term data from an outpatient monitoring trial of persons with temporal lobe epilepsy obtained with a subcutaneous EEG recording system. Subcutaneous EEG, an EMG estimate and chest-mounted accelerometry were extracted from four persons showing more than 10 well-defined electrographic seizures each. Numerous features were computed from all three modalities. Based on these, the Gini impurity measure of a Random Forest classifier was used to select the most discriminative features for the ictal fingerprint. A total of 74 electrographic seizures were analyzed. Results: The optimal individual ictal fingerprints included features extracted from all three tested modalities: an acceleration component; the power of the estimated EMG activity; and the relative power in the delta (0.5–4 Hz), low theta (4–6 Hz), and high theta (6–8 Hz) bands of the subcutaneous EEG. Multimodal ictal fingerprints were established for all persons, clustering seizures within persons, while separating seizures across persons. Conclusion: The existence of multimodal ictal fingerprints illustrates the benefits of combining multiple modalities such as EEG, EMG, and accelerometry in future epilepsy management. Multimodal ictal fingerprints could be used by doctors to get a better understanding of the individual seizure semiology of people with epilepsy. Furthermore, the multimodal ictal fingerprint gives a better understanding of how seizures manifest simultaneously in different modalities. A knowledge that could be used to improve seizure acknowledgment when reviewing EEG without video.
Collapse
Affiliation(s)
- Troels W Kjaer
- Center of Neurophysiology, Department of Neurology, Zealand University Hospital, Roskilde, Denmark.,Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Line S Remvig
- Epilepsy Science, UNEEG medical A/S, Alleroed, Denmark
| | | | | |
Collapse
|
31
|
Olsen LS, Nielsen JM, Simonÿ C, Kjær TW, Beck M. Wearables in real life: A qualitative study of experiences of people with epilepsy who use home seizure monitoring devices. Epilepsy Behav 2021; 125:108398. [PMID: 34785410 DOI: 10.1016/j.yebeh.2021.108398] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 10/18/2021] [Accepted: 10/21/2021] [Indexed: 11/18/2022]
Abstract
OBJECTIVE To explore the experiences of people with epilepsy using wearables for home seizure monitoring. METHODS Nine people with epilepsy participated in eighteen semistructured individual interviews before and after home monitoring with wearable seizure monitoring equipment. An open-ended interview guide was used to encourage the participants to elaborate on their thoughts and experiences. Interviews were analyzed using a three-level process inspired by the philosopher Max van Manen. RESULTS The overall findings illustrate that patients experienced being placed in the spotlight when wearing wearables. The meaning of being in this spotlight is reflected in three themes: Becoming vulnerable through exposure, Standing alone while being with others, and Having a renewed life situation. The analysis and interpretation showed that although the participants expressed readiness to use the wearables, they were less willing to do so after a few days of monitoring. The visibility of the devices influenced how they experienced themselves and were perceived by others. CONCLUSION For people with epilepsy, wearables are more than just technical tools; they have a significant existential impact on everyday life. Wearables spotlight the epilepsy condition, and this causes people with epilepsy to experience an existential disruption, as they experience being exposed and vulnerable. This results in a renewed way of perceiving oneself. Nevertheless, wearables also validate epilepsy symptoms, thereby reducing the uncertainty related to epilepsy.
Collapse
Affiliation(s)
- Lotte Schelde Olsen
- Department of Neurology, Zealand University Hospital, Region Sjælland. Vestermarksvej 11, 4000 Roskilde, Denmark; Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen N, Denmark.
| | - Jonas Munch Nielsen
- Department of Neurology, Zealand University Hospital, Region Sjælland. Vestermarksvej 11, 4000 Roskilde, Denmark; Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen N, Denmark
| | - Charlotte Simonÿ
- Institute of the Regional Health University of Southern Denmark, 5230 Odense, Denmark; The Research Unit PROgrez, Department of Physiotherapy and Occupational Therapy, Næstved-Slagelse-Ringsted Hospitals, Region Zealand, 4200 Slagelse, Denmark; Department of Research Naestved, Slagelse and Ringsted Hospitals, Denmark
| | - Troels Wesenberg Kjær
- Department of Neurology, Zealand University Hospital, Region Sjælland. Vestermarksvej 11, 4000 Roskilde, Denmark; Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen N, Denmark
| | - Malene Beck
- Department of Neurology, Zealand University Hospital, Region Sjælland. Vestermarksvej 11, 4000 Roskilde, Denmark; Institute of the Regional Health University of Southern Denmark, 5230 Odense, Denmark
| |
Collapse
|
32
|
Nielsen JM, Rades D, Kjaer TW. Wearable electroencephalography for ultra-long-term seizure monitoring: a systematic review and future prospects. Expert Rev Med Devices 2021; 18:57-67. [PMID: 34836477 DOI: 10.1080/17434440.2021.2012152] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
INTRODUCTION : Wearable electroencephalography (EEG) for objective seizure counting might transform the clinical management of epilepsy. Non-EEG modalities have been validated for the detection of convulsive seizures, but there is still an unmet need for the detection of non-convulsive seizures. AREAS COVERED : The main objective of this systematic review was to explore the current status on wearable surface- and subcutaneous EEG for long-term seizure monitoring in epilepsy. We included 17 studies and evaluated the progress on the field, including device specifications, intended populations, and main results on the published studies including diagnostic accuracy measures. Furthermore, we examine the hurdles for widespread clinical implementation. This systematic review and expert opinion both consults the PRISMA guidelines and reflects on the future perspectives of this emerging field. EXPERT OPINION : Wearable EEG for long-term seizure monitoring is an emerging field, with plenty of proposed devices and proof-of-concept clinical validation studies. The possible implications of these devices are immense including objective seizure counting and possibly forecasting. However, the true clinical value of the devices, including effects on patient important outcomes and clinical decision making is yet to be unveiled and large-scale clinical validation trials are called for.
Collapse
Affiliation(s)
- Jonas Munch Nielsen
- Department of Neurology, Zealand University Hospital, Region Sjælland. Vestermarksvej 11, 4000 Roskilde, Denmark.,Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen N, Denmark
| | - Dirk Rades
- Department of Radiation Oncology, University of Lübeck, Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
| | - Troels Wesenberg Kjaer
- Department of Neurology, Zealand University Hospital, Region Sjælland. Vestermarksvej 11, 4000 Roskilde, Denmark.,Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen N, Denmark
| |
Collapse
|
33
|
Ambulatory seizure forecasting with a wrist-worn device using long-short term memory deep learning. Sci Rep 2021; 11:21935. [PMID: 34754043 PMCID: PMC8578354 DOI: 10.1038/s41598-021-01449-2] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 10/22/2021] [Indexed: 11/30/2022] Open
Abstract
The ability to forecast seizures minutes to hours in advance of an event has been verified using invasive EEG devices, but has not been previously demonstrated using noninvasive wearable devices over long durations in an ambulatory setting. In this study we developed a seizure forecasting system with a long short-term memory (LSTM) recurrent neural network (RNN) algorithm, using a noninvasive wrist-worn research-grade physiological sensor device, and tested the system in patients with epilepsy in the field, with concurrent invasive EEG confirmation of seizures via an implanted recording device. The system achieved forecasting performance significantly better than a random predictor for 5 of 6 patients studied, with mean AUC-ROC of 0.80 (range 0.72–0.92). These results provide the first clear evidence that direct seizure forecasts are possible using wearable devices in the ambulatory setting for many patients with epilepsy.
Collapse
|
34
|
Hubbard I, Beniczky S, Ryvlin P. The Challenging Path to Developing a Mobile Health Device for Epilepsy: The Current Landscape and Where We Go From Here. Front Neurol 2021; 12:740743. [PMID: 34659099 PMCID: PMC8517120 DOI: 10.3389/fneur.2021.740743] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 09/03/2021] [Indexed: 11/13/2022] Open
Abstract
Seizure detection, and more recently seizure forecasting, represent important avenues of clinical development in epilepsy, promoted by progress in wearable devices and mobile health (mHealth), which might help optimizing seizure control and prevention of seizure-related mortality and morbidity in persons with epilepsy. Yet, very long-term continuous monitoring of seizure-sensitive biosignals in the ambulatory setting presents a number of challenges. We herein provide an overview of these challenges and current technological landscape of mHealth devices for seizure detection. Specifically, we display, which types of sensor modalities and analytical methods are available, and give insight into current clinical practice guidelines, main outcomes of clinical validation studies, and discuss how to evaluate device performance at point-of-care facilities. We then address pitfalls which may arise in patient compliance and the need to design solutions adapted to user experience.
Collapse
Affiliation(s)
- Ilona Hubbard
- Department of Clinical Neurosciences, Vaud University Hospital, Lausanne, Switzerland
| | - Sandor Beniczky
- Department of Clinical Neurophysiology, Danish Epilepsy Center, Dianalund, Denmark.,Department of Clinical Neurophysiology, Aarhus University Hospital, Aarhus, Denmark
| | - Philippe Ryvlin
- Department of Clinical Neurosciences, Vaud University Hospital, Lausanne, Switzerland
| |
Collapse
|
35
|
de Bruin B, Singh K, Wang Y, Huisken J, de Gyvez JP, Corporaal H. Multi-Level Optimization of an Ultra-Low Power BrainWave System for Non-Convulsive Seizure Detection. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:1107-1121. [PMID: 34665740 DOI: 10.1109/tbcas.2021.3120965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
We present a systematic evaluation and optimization of a complex bio-medical signal processing application on the BrainWave prototype system, targeted towards ambulatory EEG monitoring within a tiny power budget of 1 mW. The considered BrainWave processor is completely programmable, while maintaining energy-efficiency by means of a Coarse-Grained Reconfigurable Array (CGRA). This is demonstrated through the mapping and evaluation of a state-of-the-art non-convulsive epileptic seizure detection algorithm, while ensuring real-time operation and seizure detection accuracy. Exploiting the CGRA leads to an energy reduction of 73.1%, compared to a highly tuned software implementation (SW-only). A total of 9 complex kernels were benchmarked on the CGRA, resulting in an average 4.7 × speedup and average 4.4 × energy savings over highly tuned SW-only implementations. The BrainWave processor is implemented in 28-nm FDSOI technology with 80 kB of Foundry-provided SRAM. By exploiting near-threshold computing for the logic and voltage-stacking to minimize on-chip voltage-conversion overhead, additional 15.2% and 19.5% energy savings are obtained, respectively. At the Minimum-Energy-Point (MEP) (223 μW, 8 MHz) we report a measured state-of-the-art 90.6% system conversion efficiency, while executing the epileptic seizure detection in real-time.
Collapse
|
36
|
Shum J, Friedman D. Commercially available seizure detection devices: A systematic review. J Neurol Sci 2021; 428:117611. [PMID: 34419933 DOI: 10.1016/j.jns.2021.117611] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 08/02/2021] [Accepted: 08/03/2021] [Indexed: 10/20/2022]
Abstract
IMPORTANCE Epilepsy can be associated with significant morbidity and mortality. Seizure detection devices could be invaluable tools for both people with epilepsy, their caregivers, and clinicians as they could alert caretakers about seizures, reduce the risk of sudden unexpected death in epilepsy, and provide objective and more reliable seizure tracking to guide treatment decisions or monitor outcomes in clinical trials. OBJECTIVE To synthesize the characteristics of commercial seizure detection tools/devices currently available. METHODS We performed a systematic search utilizing a diverse set of resources to identify commercially available seizure detection products for consumer use. Performance data was obtained through a systematic review on commercially available products. OBSERVATIONS We identified 23 products marketed for seizure detection/alerting. Devices utilize a variety of mechanisms to detect seizures, including movement detectors, autonomic change detectors, electroencephalogram (EEG) based detectors, and other mechanisms (audio). The optimal device for a person with epilepsy depends on a variety of factors including the main purpose of the device, their age, seizure type and personal preferences. Only 8 devices have published peer-reviewed performance data and the majority for tonic-clonic seizures. An informed conversation between the clinician and the patient can help guide if a seizure detection device is appropriate. CONCLUSIONS AND RELEVANCE Seizure detection devices have a potential to reduce morbidity and mortality for certain people with epilepsy. Clinicians should be familiar with the characteristics of commercially available devices to best counsel their patients on whether a seizure detection device may be beneficial and what the optimal devices may be.
Collapse
Affiliation(s)
- Jennifer Shum
- Department of Neurology, Comprehensive Epilepsy Center, New York University Gross School of Medicine, New York, NY, USA.
| | - Daniel Friedman
- Department of Neurology, Comprehensive Epilepsy Center, New York University Gross School of Medicine, New York, NY, USA
| |
Collapse
|
37
|
Onorati F, Regalia G, Caborni C, LaFrance WC, Blum AS, Bidwell J, De Liso P, El Atrache R, Loddenkemper T, Mohammadpour-Touserkani F, Sarkis RA, Friedman D, Jeschke J, Picard R. Prospective Study of a Multimodal Convulsive Seizure Detection Wearable System on Pediatric and Adult Patients in the Epilepsy Monitoring Unit. Front Neurol 2021; 12:724904. [PMID: 34489858 PMCID: PMC8418082 DOI: 10.3389/fneur.2021.724904] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Accepted: 07/27/2021] [Indexed: 12/03/2022] Open
Abstract
Background: Using machine learning to combine wrist accelerometer (ACM) and electrodermal activity (EDA) has been shown effective to detect primarily and secondarily generalized tonic-clonic seizures, here termed as convulsive seizures (CS). A prospective study was conducted for the FDA clearance of an ACM and EDA-based CS-detection device based on a predefined machine learning algorithm. Here we present its performance on pediatric and adult patients in epilepsy monitoring units (EMUs). Methods: Patients diagnosed with epilepsy participated in a prospective multi-center clinical study. Three board-certified neurologists independently labeled CS from video-EEG. The Detection Algorithm was evaluated in terms of Sensitivity and false alarm rate per 24 h-worn (FAR) on all the data and on only periods of rest. Performance were analyzed also applying the Detection Algorithm offline, with a less sensitive but more specific parameters configuration (“Active mode”). Results: Data from 152 patients (429 days) were used for performance evaluation (85 pediatric aged 6–20 years, and 67 adult aged 21–63 years). Thirty-six patients (18 pediatric) experienced a total of 66 CS (35 pediatric). The Sensitivity (corrected for clustered data) was 0.92, with a 95% confidence interval (CI) of [0.85-1.00] for the pediatric population, not significantly different (p > 0.05) from the adult population's Sensitivity (0.94, CI: [0.89–1.00]). The FAR on the pediatric population was 1.26 (CI: [0.87–1.73]), higher (p < 0.001) than in the adult population (0.57, CI: [0.36–0.81]). Using the Active mode, the FAR decreased by 68% while reducing Sensitivity to 0.95 across the population. During rest periods, the FAR's were 0 for all patients, lower than during activity periods (p < 0.001). Conclusions: Performance complies with FDA's requirements of a lower bound of CI for Sensitivity higher than 0.7 and of a FAR lower than 2, for both age groups. The pediatric FAR was higher than the adult FAR, likely due to higher pediatric activity. The high Sensitivity and precision (having no false alarms) during sleep might help mitigate SUDEP risk by summoning caregiver intervention. The Active mode may be advantageous for some patients, reducing the impact of the FAR on daily life. Future work will examine the performance and usability outside of EMUs.
Collapse
Affiliation(s)
| | | | | | - W Curt LaFrance
- Division of Neuropsychiatry and Behavioral Neurology, Rhode Island Hospital, Brown University, Providence, RI, United States
| | - Andrew S Blum
- Department of Neurology, Rhode Island Hospital, Brown University, Providence, RI, United States
| | | | - Paola De Liso
- Department of Neuroscience, Bambino Gesù Children's Hospital, Istituto di Ricovero e Cura a Carattere Scientifico, Rome, Italy
| | - Rima El Atrache
- Department of Neurology, Boston Children's Hospital, Boston, MA, United States
| | - Tobias Loddenkemper
- Department of Neurology, Boston Children's Hospital, Boston, MA, United States
| | | | - Rani A Sarkis
- Department of Neurology, Brigham and Women's Hospital, Boston, MA, United States
| | - Daniel Friedman
- Department of Neurology, New York University Langone Medical Center, New York, NY, United States
| | - Jay Jeschke
- Department of Neurology, New York University Langone Medical Center, New York, NY, United States
| | - Rosalind Picard
- Empatica, Inc., Boston, MA, United States.,MIT Media Lab, Massachusetts Institute of Technology, Cambridge, MA, United States
| |
Collapse
|
38
|
Monfort E, Poulet C, Nahas C, Bakridan S, Clair L, Latour P. Clustering patients and caregivers for technology design: A step prior to the design of an innovative technological device for the detection of epileptic seizures. Epilepsy Behav 2021; 122:108233. [PMID: 34352671 DOI: 10.1016/j.yebeh.2021.108233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 07/19/2021] [Accepted: 07/19/2021] [Indexed: 10/20/2022]
Abstract
AIMS Seizure detection using heart rate variability, from a detailed analysis by deep learning analysis system, may help patients with epilepsy to manage their symptoms. This exploratory study aims to identify patient and caregiver groups, according to acceptability factors. METHODS Two versions of the same questionnaire were designed to survey quality of life, self-efficacy, and patients with epilepsy and caregivers on seizure detection acceptability using a patch, after watching a video that described a patch connected to a companion application. Participation was voluntary and anonymous. RESULTS Responses from 68 patients with epilepsy and 33 caregivers were collected. Patients with epilepsy were grouped into three clusters: supportive, indeterminate, and reluctant to use the technology. Caregivers were also grouped into three clusters: supportive, reluctant to use the technology, either with sensitivity to their environment, or with hedonic motivation. The clusters enable the distinction between participants in self-efficacy. CONCLUSIONS Clustering of patients with epilepsy and caregivers should be a prerequisite to the design of a technological device intended to promote self-management of seizure detection. These groupings distinguish those who are favorable, reluctant or undecided to use the technology. These can be based on an assessment of self-efficacy.
Collapse
Affiliation(s)
| | | | | | | | - Laetitia Clair
- Medical Center of La Teppe, 26600 Tain-l'Hermitage, France
| | - Patrick Latour
- Medical Center of La Teppe, 26600 Tain-l'Hermitage, France
| |
Collapse
|
39
|
Chakrabarti S, Swetapadma A, Pattnaik PK. A channel independent generalized seizure detection method for pediatric epileptic seizures. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 209:106335. [PMID: 34390934 DOI: 10.1016/j.cmpb.2021.106335] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 07/27/2021] [Indexed: 06/13/2023]
Abstract
BACKGROUND AND OBJECTIVE Epilepsy the disorder of the central nervous system has its worldwide presence in roughly 50 million people as estimated by the World Health Organization. Electroencephalogram (EEG) is one of the most common and non-invasive ways of analyzing and studying the subtle changes in neuronal activity of the brain during an epileptic seizure attack. These changes can be analyzed for developing an automated system that would assert the chances of an impending seizure. As changeable nature of seizure affects the patients from having a normal life, hence progress in developing new methods will improve the quality of life and also provide assistance in the medical sector. Objective of the proposed method is to avoid EEG channel selection and use all input EEG channel features to design a generalized epileptic seizure detection framework. METHOD In this work, a long short-term memory network has been proposed that is not complex and has the capability of effectively detecting epileptic seizures from both non-invasive and invasive electroencephalogram recordings. The proposed framework is simple and effective and designed in such capacity that raw electroencephalogram signals can be used to detect seizures. Also, a generalized approach has been followed that is channel independent such that EEG signals belonging to any hemisphere of the brain can be detected effectively by the proposed architecture. RESULTS The automated seizure detection system achieved high seizure detection sensitivity of 99.9%, and a low false-positive rate of 0.003 per hour for the Children's Hospital Boston-Massachusetts Institute of Technology dataset. While for the Sleep-Wake-Epilepsy-Center of the University Department of Neurology at the Inselspital Bern dataset, the sensitivity is 99.4% and false-positive rate of 0.006 per hour. Convergence analysis of the proposed model provides a significant amount of reliability and correctness in the efficient detection of epileptic seizures. CONCLUSION Assessment of the proposed framework on non-invasive as well as invasive EEG signals showed that the framework worked well for different type of EEG recordings as different metrics gave satisfactory results. As the framework is simple and did not require any additional parameter optimization techniques, it reduced the processing overheads without affecting the accuracy. Hence, it can be used as an efficient method for monitoring epileptic seizures.
Collapse
Affiliation(s)
- Satarupa Chakrabarti
- School of Computer Engineering, KIIT University, Bhubaneswar, Odisha 751024, India
| | - Aleena Swetapadma
- School of Computer Engineering, KIIT University, Bhubaneswar, Odisha 751024, India.
| | | |
Collapse
|
40
|
Bruno E, Böttcher S, Viana PF, Amengual-Gual M, Joseph B, Epitashvili N, Dümpelmann M, Glasstetter M, Biondi A, Van Laerhoven K, Loddenkemper T, Richardson MP, Schulze-Bonhage A, Brinkmann BH. Wearable devices for seizure detection: Practical experiences and recommendations from the Wearables for Epilepsy And Research (WEAR) International Study Group. Epilepsia 2021; 62:2307-2321. [PMID: 34420211 DOI: 10.1111/epi.17044] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 07/20/2021] [Accepted: 08/05/2021] [Indexed: 02/06/2023]
Abstract
The Wearables for Epilepsy And Research (WEAR) International Study Group identified a set of methodology standards to guide research on wearable devices for seizure detection. We formed an international consortium of experts from clinical research, engineering, computer science, and data analytics at the beginning of 2020. The study protocols and practical experience acquired during the development of wearable research studies were discussed and analyzed during bi-weekly virtual meetings to highlight commonalities, strengths, and weaknesses, and to formulate recommendations. Seven major essential components of the experimental design were identified, and recommendations were formulated about: (1) description of study aims, (2) policies and agreements, (3) study population, (4) data collection and technical infrastructure, (5) devices, (6) reporting results, and (7) data sharing. Introducing a framework of methodology standards promotes optimal, accurate, and consistent data collection. It also guarantees that studies are generalizable and comparable, and that results can be replicated, validated, and shared.
Collapse
Affiliation(s)
- Elisa Bruno
- Division of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK
| | - Sebastian Böttcher
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg, Germany.,Ubiquitous Computing, Department of Electrical Engineering and Computer Science, University of Siegen, Siegen, Germany
| | - Pedro F Viana
- Division of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK.,Faculty of Medicine, University of Lisbon, Lisboa, Portugal
| | - Marta Amengual-Gual
- Division of Epilepsy and Clinical Neurophysiology, Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Boney Joseph
- Department of Neurology and Biomedical Engineering, Mayo Foundation, Rochester, Minnesota, USA
| | - Nino Epitashvili
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg, Germany
| | - Matthias Dümpelmann
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg, Germany
| | - Martin Glasstetter
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg, Germany
| | - Andrea Biondi
- Division of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK
| | - Kristof Van Laerhoven
- Ubiquitous Computing, Department of Electrical Engineering and Computer Science, University of Siegen, Siegen, Germany
| | - Tobias Loddenkemper
- Division of Epilepsy and Clinical Neurophysiology, Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Mark P Richardson
- Division of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK
| | - Andreas Schulze-Bonhage
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg, Germany
| | - Benjamin H Brinkmann
- Department of Neurology and Biomedical Engineering, Mayo Foundation, Rochester, Minnesota, USA
| |
Collapse
|
41
|
Biondi A, Laiou P, Bruno E, Viana PF, Schreuder M, Hart W, Nurse E, Pal DK, Richardson MP. Remote and Long-Term Self-Monitoring of Electroencephalographic and Noninvasive Measurable Variables at Home in Patients With Epilepsy (EEG@HOME): Protocol for an Observational Study. JMIR Res Protoc 2021; 10:e25309. [PMID: 33739290 PMCID: PMC8088854 DOI: 10.2196/25309] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 12/22/2020] [Accepted: 12/23/2020] [Indexed: 01/06/2023] Open
Abstract
Background Epileptic seizures are spontaneous events that severely affect the lives of patients due to their recurrence and unpredictability. The integration of new wearable and mobile technologies to collect electroencephalographic (EEG) and extracerebral signals in a portable system might be the solution to prospectively identify times of seizure occurrence or propensity. The performances of several seizure detection devices have been assessed by validated studies, and patient perspectives on wearables have been explored to better match their needs. Despite this, there is a major gap in the literature on long-term, real-life acceptability and performance of mobile technology essential to managing chronic disorders such as epilepsy. Objective EEG@HOME is an observational, nonrandomized, noninterventional study that aims to develop a new feasible procedure that allows people with epilepsy to independently, continuously, and safely acquire noninvasive variables at home. The data collected will be analyzed to develop a general model to predict periods of increased seizure risk. Methods A total of 12 adults with a diagnosis of pharmaco-resistant epilepsy and at least 20 seizures per year will be recruited at King’s College Hospital, London. Participants will be asked to self-apply an easy and portable EEG recording system (ANT Neuro) to record scalp EEG at home twice daily. From each serial EEG recording, brain network ictogenicity (BNI), a new biomarker of the propensity of the brain to develop seizures, will be extracted. A noninvasive wrist-worn device (Fitbit Charge 3; Fitbit Inc) will be used to collect non-EEG biosignals (heart rate, sleep quality index, and steps), and a smartphone app (Seer app; Seer Medical) will be used to collect data related to seizure occurrence, medication taken, sleep quality, stress, and mood. All data will be collected continuously for 6 months. Standardized questionnaires (the Post-Study System Usability Questionnaire and System Usability Scale) will be completed to assess the acceptability and feasibility of the procedure. BNI, continuous wrist-worn sensor biosignals, and electronic survey data will be correlated with seizure occurrence as reported in the diary to investigate their potential values as biomarkers of seizure risk. Results The EEG@HOME project received funding from Epilepsy Research UK in 2018 and was approved by the Bromley Research Ethics Committee in March 2020. The first participants were enrolled in October 2020, and we expect to publish the first results by the end of 2022. Conclusions With the EEG@HOME study, we aim to take advantage of new advances in remote monitoring technology, including self-applied EEG, to investigate the feasibility of long-term disease self-monitoring. Further, we hope our study will bring new insights into noninvasively collected personalized risk factors of seizure occurrence and seizure propensity that may help to mitigate one of the most difficult aspects of refractory epilepsy: the unpredictability of seizure occurrence. International Registered Report Identifier (IRRID) PRR1-10.2196/25309
Collapse
Affiliation(s)
- Andrea Biondi
- Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, United Kingdom
| | - Petroula Laiou
- Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, United Kingdom
| | - Elisa Bruno
- Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, United Kingdom
| | - Pedro F Viana
- Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, United Kingdom.,Faculty of Medicine, University of Lisbon, Hospital de Santa Maria, Lisbon, Portugal
| | | | | | - Ewan Nurse
- Seer Medical Inc, Melbourne, Australia.,Department of Medicine, St. Vincent's Hospital Melbourne, The University of Melbourne, Melbourne, Australia
| | - Deb K Pal
- Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, United Kingdom
| | - Mark P Richardson
- Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, United Kingdom
| |
Collapse
|
42
|
Abstract
Machine Learning From Wristband Sensor Data for Wearable, Noninvasive Seizure Forecasting Meisel C, El Atrache R, Jackson M, Schubach S, Ufongene C, Loddenkemper T. Epilepsia. 2020;61(12):2653-2666. doi:10.1111/epi.16719 Objective: Seizure forecasting may provide patients with timely warnings to adapt their daily activities and help clinicians deliver more objective, personalized treatments. Although recent work has convincingly demonstrated that seizure risk assessment is in principle possible, these early approaches relied largely on complex, often invasive setups including intracranial electrocorticography, implanted devices, and multichannel electroencephalography and required patient-specific adaptation or learning to perform optimally, all of which limit translation to broad clinical application. To facilitate broader adaptation of seizure forecasting in clinical practice, noninvasive, easily applicable techniques that reliably assess seizure risk without much prior tuning are crucial. Wristbands that continuously record physiological parameters, including electrodermal activity, body temperature, blood volume pulse, and actigraphy, may afford monitoring of autonomous nervous system function and movement relevant for such a task, hence minimizing potential complications associated with invasive monitoring and avoiding stigma associated with bulky external monitoring devices on the head. Methods: Here, we applied deep learning on multimodal wristband sensor data from 69 patients with epilepsy (total duration >2311 hours, 452 seizures) to assess its capability to forecast seizures in a statistically significant way. Results: Using a leave-one-subject-out cross-validation approach, we identified better-than-chance predictability in 43% of the patients. Time-matched seizure surrogate data analyses indicated forecasting not to be driven simply by time of day or vigilance state. Prediction performance peaked when all sensor modalities were used and did not differ between generalized and focal seizure types but generally increased with the size of the training data set, indicating potential further improvement with larger data sets in the future. Significance: Collectively, these results show that statistically significant seizure risk assessments are feasible from easy-to-use, noninvasive wearable devices without the need of patient-specific training or parameter optimization.
Collapse
|
43
|
Feyissa AM. Hold the Smartphone! Tele-epilepsy in a Post-COVID-19 World. Mayo Clin Proc 2021; 96:4-6. [PMID: 33413834 DOI: 10.1016/j.mayocp.2020.11.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Accepted: 11/17/2020] [Indexed: 12/18/2022]
|
44
|
Viana PF, Duun-Henriksen J, Glasstëter M, Dümpelmann M, Nurse ES, Martins IP, Dumanis SB, Schulze-Bonhage A, Freestone DR, Brinkmann BH, Richardson MP. 230 days of ultra long-term subcutaneous EEG: seizure cycle analysis and comparison to patient diary. Ann Clin Transl Neurol 2020; 8:288-293. [PMID: 33275838 PMCID: PMC7818131 DOI: 10.1002/acn3.51261] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 10/23/2020] [Accepted: 11/10/2020] [Indexed: 12/19/2022] Open
Abstract
We describe the longest period of subcutaneous EEG (sqEEG) monitoring to date, in a 35‐year‐old female with refractory epilepsy. Over 230 days, 4791/5520 h of sqEEG were recorded (86%, mean 20.8 [IQR 3.9] hours/day). Using an electronic diary, the patient reported 22 seizures, while automatically‐assisted visual sqEEG review detected 32 seizures. There was substantial agreement between days of reported and recorded seizures (Cohen’s kappa 0.664), although multiple clustered seizures remained undocumented. Circular statistics identified significant sqEEG seizure cycles at circadian (24‐hour) and multidien (5‐day) timescales. Electrographic seizure monitoring and analysis of long‐term seizure cycles are possible with this neurophysiological tool.
Collapse
Affiliation(s)
- Pedro F Viana
- Institute of Psychiatry, Psychology and Neuroscience, King's College London, London, United Kingdom.,Faculty of Medicine, University of Lisbon, Lisboa, Portugal
| | | | - Martin Glasstëter
- Epilepsy Center, Department for Neurosurgery, University Medical Center Freiburg, Freiburg, Germany
| | - Matthias Dümpelmann
- Epilepsy Center, Department for Neurosurgery, University Medical Center Freiburg, Freiburg, Germany
| | - Ewan S Nurse
- Seer Medical Inc., Melbourne, Victoria, Australia.,Department of Medicine, St. Vincent's Hospital, University of Melbourne, Melbourne, Victoria, Australia
| | | | | | - Andreas Schulze-Bonhage
- Epilepsy Center, Department for Neurosurgery, University Medical Center Freiburg, Freiburg, Germany
| | - Dean R Freestone
- Seer Medical Inc., Melbourne, Victoria, Australia.,Department of Medicine, St. Vincent's Hospital, University of Melbourne, Melbourne, Victoria, Australia
| | - Benjamin H Brinkmann
- Mayo Systems Electrophysiology Laboratory, Department of Neurology, Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota, USA
| | - Mark P Richardson
- Institute of Psychiatry, Psychology and Neuroscience, King's College London, London, United Kingdom
| |
Collapse
|
45
|
Craven MP, Andrews JA, Lang AR, Simblett SK, Bruce S, Thorpe S, Wykes T, Morriss R, Hollis C. Informing the Development of a Digital Health Platform Through Universal Points of Care: Qualitative Survey Study. JMIR Form Res 2020; 4:e22756. [PMID: 33242009 PMCID: PMC7728533 DOI: 10.2196/22756] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 09/17/2020] [Accepted: 09/30/2020] [Indexed: 01/14/2023] Open
Abstract
Background Epilepsy, multiple sclerosis (MS), and depression are chronic conditions where technology holds potential in clinical monitoring and self-management. Over 5 years, the Remote Assessment of Disease and Relapse - Central Nervous System (RADAR-CNS) consortium has explored the application of remote measurement technology (RMT) to the management and self-management of patients in these clinical areas. The consortium is large and includes clinical and nonclinical researchers as well as a patient advisory board. Objective This formative development study aimed to understand how consortium members viewed the potential of RMT in epilepsy, MS, and depression. Methods In this qualitative survey study, we developed a methodological tool, universal points of care (UPOC), to gather views on the potential use, acceptance, and value of a novel RMT platform across 3 chronic conditions (MS, epilepsy, and depression). UPOC builds upon use case scenario methodology, using expert elicitation and analysis of care pathways to develop scenarios applicable across multiple conditions. After developing scenarios, we elicited views on the potential of RMT in these different scenarios through a survey administered to 28 subject matter experts, consisting of 16 health care practitioners; 5 health care services researchers; and 7 people with lived experience of MS, epilepsy, or depression. Survey results were analyzed thematically and using an existing framework of factors describing links between design and context. Results The survey elicited potential beneficial applications of the RADAR-CNS RMT system as well as patient, clinical, and nonclinical requirements of RMT across the 3 conditions of interest. Potential applications included recognition of early warning signs of relapse from subclinical signals for MS, seizure precipitant signals for epilepsy, and behavior change in depression. RMT was also thought to have the potential to overcome the problem of underreporting, which is especially problematic in epilepsy, and to allow the capture of secondary symptoms that are not generally collected in MS, such as mood. Conclusions Respondents suggested novel and unanticipated uses of RMT, including the use of RMT to detect emerging side effects of treatment, enable behavior change for sleep regulation and activity, and offer a way to include family and other carers in a care network, which could assist with goal setting. These suggestions, together with others from this and related work, will inform the development of the system for its eventual application in research and clinical practice. The UPOC methodology was effective in directing respondents to consider the value of health care technologies in condition-specific experiences of everyday life and working practice.
Collapse
Affiliation(s)
- Michael P Craven
- NIHR Mindtech Medtech Co-operative, Institute of Mental Health, University of Nottingham, Nottingham, United Kingdom.,Bioengineering Research Group, Faculty of Engineering, University of Nottingham, Nottingham, United Kingdom.,NIHR Nottingham Biomedical Research Centre, University of Nottingham, Nottingham, United Kingdom
| | - Jacob A Andrews
- NIHR Mindtech Medtech Co-operative, Institute of Mental Health, University of Nottingham, Nottingham, United Kingdom.,Division of Psychiatry and Applied Psychology, Institute of Mental Health, School of Medicine, University of Nottingham, Nottingham, United Kingdom
| | - Alexandra R Lang
- Human Factors Research Group, Faculty of Engineering, University of Nottingham, Nottingham, United Kingdom
| | - Sara K Simblett
- Institute of Psychology, Psychiatry and Neuroscience, King's College London, London, United Kingdom
| | - Stuart Bruce
- Patient Advisory Board, RADAR-CNS, London, United Kingdom
| | - Sarah Thorpe
- Patient Advisory Board, RADAR-CNS, London, United Kingdom
| | - Til Wykes
- Institute of Psychology, Psychiatry and Neuroscience, King's College London, London, United Kingdom.,NIHR Biomedical Research Centre for Mental Health, South London and Maudsley NHS Foundation Trust, London, United Kingdom
| | - Richard Morriss
- NIHR Nottingham Biomedical Research Centre, University of Nottingham, Nottingham, United Kingdom.,Division of Psychiatry and Applied Psychology, Institute of Mental Health, School of Medicine, University of Nottingham, Nottingham, United Kingdom
| | - Chris Hollis
- NIHR Mindtech Medtech Co-operative, Institute of Mental Health, University of Nottingham, Nottingham, United Kingdom.,Division of Psychiatry and Applied Psychology, Institute of Mental Health, School of Medicine, University of Nottingham, Nottingham, United Kingdom
| | | |
Collapse
|
46
|
Ryvlin P, Beniczky S. Seizure detection and mobile health devices in epilepsy: Recent developments and future perspectives. Epilepsia 2020; 61 Suppl 1:S1-S2. [PMID: 33098105 DOI: 10.1111/epi.16702] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Accepted: 08/04/2020] [Indexed: 10/23/2022]
Affiliation(s)
- Philippe Ryvlin
- Department of Clinical Neurosciences, CHUV, Lausanne, Switzerland
| | - Sándor Beniczky
- Department of Clinical Neurophysiology, Aarhus University Hospital and Danish Epilepsy Center, Dianalund, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
47
|
Sattar S, Kuperman R. Telehealth in pediatric epilepsy care: A rapid transition during the COVID-19 pandemic. Epilepsy Behav 2020; 111:107282. [PMID: 32759065 PMCID: PMC7386847 DOI: 10.1016/j.yebeh.2020.107282] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 06/18/2020] [Accepted: 06/20/2020] [Indexed: 11/29/2022]
Abstract
Telehealth's first literature reference is an article in 1879 in the Lancet about using the telephone to reduce unnecessary office visits (Institute of Medicine & Board on Health Care Services, 2012). However, providers have been slow to adopt telehealth into their clinical practice secondary to barriers such as cost and reimbursement (Kane and Gillis, 2018) [2]. The advent of shelter in place orders combined with the ongoing need defined by the Centers for Medicare & Medicaid Services (CMS) Administrator Seema Verma "for all Americans, and particularly vulnerable populations who are at heightened risk, to be able to access their providers" has resulted in the rapid implementation of telehealth across multiple specialties. The goal of this paper is to provide a practical framework for translating quality care in epilepsy as defined by the American Academy of Neurology (AAN) guidelines into a virtual care environment. We will also discuss the use and limitations of point of care testing in epilepsy management.
Collapse
Affiliation(s)
- Shifteh Sattar
- University of California, San Diego, Comprehensive Epilepsy Center, Rady Children's Hospital, 3020 Children's Way, San Diego, CA 92123, United States of America.
| | - Rachel Kuperman
- Eysz, Inc., 107 Sandringham Road, Piedmont, CA 94611, United States of America.
| |
Collapse
|
48
|
Duun-Henriksen J, Baud M, Richardson MP, Cook M, Kouvas G, Heasman JM, Friedman D, Peltola J, Zibrandtsen IC, Kjaer TW. A new era in electroencephalographic monitoring? Subscalp devices for ultra-long-term recordings. Epilepsia 2020; 61:1805-1817. [PMID: 32852091 DOI: 10.1111/epi.16630] [Citation(s) in RCA: 93] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Revised: 06/16/2020] [Accepted: 07/05/2020] [Indexed: 12/21/2022]
Abstract
Inaccurate subjective seizure counting poses treatment and diagnostic challenges and thus suboptimal quality in epilepsy management. The limitations of existing hospital- and home-based monitoring solutions are motivating the development of minimally invasive, subscalp, implantable electroencephalography (EEG) systems with accompanying cloud-based software. This new generation of ultra-long-term brain monitoring systems is setting expectations for a sea change in the field of clinical epilepsy. From definitive diagnoses and reliable seizure logs to treatment optimization and presurgical seizure foci localization, the clinical need for continuous monitoring of brain electrophysiological activity in epilepsy patients is evident. This paper presents the converging solutions developed independently by researchers and organizations working at the forefront of next generation EEG monitoring. The immediate value of these devices is discussed as well as the potential drivers and hurdles to adoption. Additionally, this paper discusses what the expected value of ultra-long-term EEG data might be in the future with respect to alarms for especially focal seizures, seizure forecasting, and treatment personalization.
Collapse
Affiliation(s)
- Jonas Duun-Henriksen
- Department of Basic & Clinical Neuroscience, King's College London, London, UK.,UNEEG medical, Lynge, Denmark
| | - Maxime Baud
- Sleep-Wake-Epilepsy Center and Center for Experimental Neurology, Department of Neurology, Bern University Hospital, University of Bern, Bern, Switzerland.,Wyss Center for Bio and Neuroengineering, Geneva, Switzerland
| | - Mark P Richardson
- Department of Basic & Clinical Neuroscience, King's College London, London, UK
| | - Mark Cook
- Graeme Clark Institute, University of Melbourne, Melbourne, Victoria, Australia.,Epi-Minder, Melbourne, Victoria, Australia
| | - George Kouvas
- Wyss Center for Bio and Neuroengineering, Geneva, Switzerland
| | | | - Daniel Friedman
- NYU Langone Comprehensive Epilepsy Center, New York, New York, USA
| | - Jukka Peltola
- Department of Neurology, Tampere University and Tampere University Hospital, Tampere, Finland
| | - Ivan C Zibrandtsen
- Center of Neurophysiology, Department of Neurology, Zealand University Hospital, Roskilde, Denmark
| | - Troels W Kjaer
- Center of Neurophysiology, Department of Neurology, Zealand University Hospital, Roskilde, Denmark.,Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|