1
|
Aganovic A, Cao G, Kurnitski J, Melikov A, Wargocki P. Zonal modeling of air distribution impact on the long-range airborne transmission risk of SARS-CoV-2. Appl Math Model 2022; 112:800-821. [PMID: 36060304 PMCID: PMC9420246 DOI: 10.1016/j.apm.2022.08.027] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2022] [Revised: 08/15/2022] [Accepted: 08/25/2022] [Indexed: 05/10/2023]
Abstract
A widely used analytical model to quantitatively assess airborne infection risk is the Wells-Riley model which is limited to complete air mixing in a single zone. However, this assumption tends not to be feasible (or reality) for many situations. This study aimed to extend the Wells-Riley model so that the infection risk can be calculated in spaces where complete mixing is not present. Some more advanced ventilation concepts create either two horizontally divided air zones in spaces as displacement ventilation or the space may be divided into two vertical zones by downward plane jet as in protective-zone ventilation systems. This is done by evaluating the time-dependent distribution of infectious quanta in each zone and by solving the coupled system of differential equations based on the zonal quanta concentrations. This model introduces a novel approach by estimating the interzonal mixing factor based on previous experimental data for three types of ventilation systems: incomplete mixing ventilation, displacement ventilation, and protective zone ventilation. The modeling approach is applied to a room with one infected and one susceptible person present. The results show that using the Wells-Riley model based on the assumption of completely air mixing may considerably overestimate or underestimate the long-range airborne infection risk in rooms where air distribution is different than complete mixing, such as displacement ventilation, protected zone ventilation, warm air supplied from the ceiling, etc. Therefore, in spaces with non-uniform air distribution, a zonal modeling approach should be preferred in analytical models compared to the conventional single-zone Wells-Riley models when assessing long-range airborne transmission risk of infectious respiratory diseases.
Collapse
Affiliation(s)
- Amar Aganovic
- Department of Automation and Process Engineering, UiT The Arctic University of Norway, Postboks 6050 Langnes, Tromsø 9037, Norway
| | - Guangyu Cao
- Department of Energy and Process Engineering, Norwegian University of Science and Technology - NTNU, Trondheim, Norway
| | - Jarek Kurnitski
- REHVA Technology and Research Committee, Tallinn University of Technology, Tallinn, Estonia
| | - Arsen Melikov
- Department of Civil Engineering, Technical University of Denmark, Copenhagen, Denmark
| | - Pawel Wargocki
- Department of Civil Engineering, Technical University of Denmark, Copenhagen, Denmark
| |
Collapse
|
2
|
Chen J, Jin L, Yang B, Chen Z, Zhang G. Influence of the Internal Structure Type of a Large-Area Lower Exhaust Workbench on Its Surface Air Distribution. Int J Environ Res Public Health 2022; 19:11395. [PMID: 36141667 PMCID: PMC9517492 DOI: 10.3390/ijerph191811395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2022] [Revised: 08/14/2022] [Accepted: 09/08/2022] [Indexed: 06/16/2023]
Abstract
Local exhaust ventilation is an important method of contamination control, and the type of exhaust hood and the air distribution at the hood face have an important influence on the contamination control effect. When the hood face is large, it is difficult to create a uniform airflow distribution at the hood face, which if achieved, could improve the effect of contamination control. To that end, the large-area workbench used in the process of vaccine purification was taken as the research subject prototype for this study. According to the methods for generating a uniform airflow distribution at the hood face, the lower exhaust workbenches of four structures were established using CAD and simulated using Ansys Fluent. The best uniformity of workbench surface air distribution was with Structure-4, while the worst was with Structure-1. The workbench surface airflow distribution could not achieve uniformity when only an inclined bottom was used for the large-area lower exhaust workbench with one side outlet. The more internal slits there were, the greater the air distribution area and the more uniform the air distribution. The width of the area of workbench surface airflow distribution was determined by the width of the slits. The numerical simulation results were verified by experiments, which showed them to be credible.
Collapse
Affiliation(s)
- Jianwu Chen
- School of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, China
- Institute of Occupational Health, China Academy of Safety Science and Technology, Beijing 100012, China
| | - Longzhe Jin
- School of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Bin Yang
- School of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, China
- Institute of Occupational Health, China Academy of Safety Science and Technology, Beijing 100012, China
| | - Zhenfang Chen
- Institute of Occupational Health, China Academy of Safety Science and Technology, Beijing 100012, China
| | - Guoliang Zhang
- School of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, China
| |
Collapse
|
3
|
Xiao L, Du Z. Effects of Evaporative Cooling Air Conditioning on Classroom Pollutants and Thermal Environment. Environ Health Insights 2022; 16:11786302221113995. [PMID: 35899225 PMCID: PMC9310290 DOI: 10.1177/11786302221113995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Accepted: 06/29/2022] [Indexed: 06/15/2023]
Abstract
Indoor particles and carbon dioxide concentration are major indices to evaluate indoor air quality. Based on the two-dimensional filler sieving model of the direct evaporative cooling segment, the porous media model was used for the simulation of the water filler section, the filtering efficiency of particle was simulated by adjusting the water drenching density and airflow velocity in different operating conditions. The three-dimensional classroom model used to change the exhaust outlet position and control the use of air conditioners simulated the indoor thermal environment and the changes in pollutant concentration. The Euler method and Lagrangian method were used to analyze the indoor flow field and particle sieving in the direct evaporation section, respectively. Conclusions show that in the application of evaporative cooling and stratum ventilation air conditioning system in classroom, the position of the exhaust port affects the concentration of carbon dioxide in the student's breathing area. The water filler section can effectively reduce the concentration of particle and carbon dioxide supplied indoors. The filtration efficiency of particle in outdoor air passing through the direct evaporative cooling section based on diffusion, inertial collision, and interception is affected by the combined effect of particle size, onward wind speed, and water spray density. The filtration efficiency of particle increases as the density of the spray water increases. With the increase of head-on wind speed, the filtration efficiency of coarse particulate matter is higher than that of fine particulate matter. The research results help policy makers decide whether to install evaporative cooling air conditioning in schools and determine which exhaust outlet positions are most effective in improving indoor air quality.
Collapse
Affiliation(s)
| | - Zhenyu Du
- Zhenyu Du, College of Civil Engineering, Taiyuan University of Technology, No. 79 West Street Yingze, Taiyuan, Shanxi 030024, China.
| |
Collapse
|
4
|
Wang C, Wang J, Norbäck D. A Systematic Review of Associations between Energy Use, Fuel Poverty, Energy Efficiency Improvements and Health. Int J Environ Res Public Health 2022; 19:ijerph19127393. [PMID: 35742650 PMCID: PMC9223700 DOI: 10.3390/ijerph19127393] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 06/13/2022] [Accepted: 06/15/2022] [Indexed: 11/16/2022]
Abstract
Energy use in buildings can influence the indoor environment. Studies on green buildings, energy saving measures, energy use, fuel poverty, and ventilation have been reviewed, following the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The database PubMed was searched for articles published up to 1 October 2020. In total, 68 relevant peer-reviewed epidemiological or exposure studies on radon, biological agents, and chemicals were included. The main aim was to assess current knowledge on how energy saving measures and energy use can influence health. The included studies concluded that buildings classified as green buildings can improve health. More efficient heating and increased thermal insulation can improve health in homes experiencing fuel poverty. However, energy-saving measures in airtight buildings and thermal insulation without installation of mechanical ventilation can impair health. Energy efficiency retrofits can increase indoor radon which can cause lung cancer. Installation of a mechanical ventilation systems can solve many of the negative effects linked to airtight buildings and energy efficiency retrofits. However, higher ventilation flow can increase the indoor exposure to outdoor air pollutants in areas with high levels of outdoor air pollution. Finally, future research needs concerning energy aspects of buildings and health were identified.
Collapse
|
5
|
Izadyar N, Miller W. Ventilation strategies and design impacts on indoor airborne transmission: A review. Build Environ 2022; 218:109158. [PMID: 35573806 PMCID: PMC9075988 DOI: 10.1016/j.buildenv.2022.109158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 04/26/2022] [Accepted: 04/29/2022] [Indexed: 06/15/2023]
Abstract
The COVID-19 outbreak has brought the indoor airborne transmission issue to the forefront. Although ventilation systems provide clean air and dilute indoor contaminated air, there is strong evidence that airborne transmission is the main route for contamination spread. This review paper aims to critically investigate ventilation impacts on particle spread and identify efficient ventilation strategies in controlling aerosol distribution in clinical and non-clinical environments. This article also examines influential ventilation design features (i.e., exhaust location) affecting ventilation performance in preventing aerosols spread. This paper shortlisted published documents for a review based on identification (keywords), pre-processing, screening, and eligibility of these articles. The literature review emphasizes the importance of ventilation systems' design and demonstrates all strategies (i.e., mechanical ventilation) could efficiently remove particles if appropriately designed. The study highlights the need for occupant-based ventilation systems, such as personalized ventilation instead of central systems, to reduce cross-infections. The literature underlines critical impacts of design features like ventilation rates and the number and location of exhausts and suggests designing systems considering airborne transmission. This review underpins that a higher ventilation rate should not be regarded as a sole indicator for designing ventilation systems because it cannot guarantee reducing risks. Using filtration and decontamination devices based on building functionalities and particle sizes can also increase ventilation performance. This paper suggests future research on optimizing ventilation systems, particularly in high infection risk spaces such as multi-storey hotel quarantine facilities. This review contributes to adjusting ventilation facilities to control indoor aerosol transmission.
Collapse
Affiliation(s)
- Nima Izadyar
- School of Built Environment, College of Engineering and Science, Victoria University, Melbourne, VIC, Australia
| | - Wendy Miller
- School of Architecture & Built Environment, Science and Engineering Faculty, Queensland University of Technology (QUT), Brisbane, QLD, 4001, Australia
| |
Collapse
|
6
|
Abstract
Heating, Ventilation, and Air-Conditioning (HVAC) system that is almost indispensable service system of modern buildings is recognized as the most important engineering control measure against pandemics. However, the effectiveness of HVAC systems has been questioned on their ability to control airborne transmission. After the outbreak of COVID-19, China has controlled the spread within a relatively short period. Considering the large population, high population density, busy transportation and the overall underdeveloped economy, China's control measures may have some implications to other countries, especially those with limited resources. This paper intends to provide a systematic summary of Chinese ventilation guidelines issued to cope with COVID-19 transmission. The following three aspects are the main focus of these guidelines: (1) general operation and management schemes of various types of HVAC systems, (2) operation and management schemes of HVAC system in typical types of buildings, and (3) design schemes of HVAC system of makeshift hospitals. In addition, some important differences in HVAC guidelines between China and other countries/institutions are identified and compared, and the possible reasons are discussed. Further discussions are made on the following topics, including the required fresh air supply, the extended operation time, the use of auxiliary equipment, the limited capacity of existing systems, and the use of personalized systems.
Collapse
Affiliation(s)
- Jinjun Ye
- Department of Building Environment and Energy, College of Civil Engineering, Hunan University, Changsha, Hunan, China
- National Center for International Research Collaboration in Building Safety and Environment, Hunan University, Changsha, Hunan, China
| | - Chen Lin
- Department of Building Environment and Energy, College of Civil Engineering, Hunan University, Changsha, Hunan, China
- National Center for International Research Collaboration in Building Safety and Environment, Hunan University, Changsha, Hunan, China
| | - Jing Liu
- Department of Building Environment and Energy, College of Civil Engineering, Hunan University, Changsha, Hunan, China
- National Center for International Research Collaboration in Building Safety and Environment, Hunan University, Changsha, Hunan, China
| | - Zhengtao Ai
- Department of Building Environment and Energy, College of Civil Engineering, Hunan University, Changsha, Hunan, China
- National Center for International Research Collaboration in Building Safety and Environment, Hunan University, Changsha, Hunan, China
| | - Guoqiang Zhang
- Department of Building Environment and Energy, College of Civil Engineering, Hunan University, Changsha, Hunan, China
- National Center for International Research Collaboration in Building Safety and Environment, Hunan University, Changsha, Hunan, China
| |
Collapse
|
7
|
Sheikhnejad Y, Aghamolaei R, Fallahpour M, Motamedi H, Moshfeghi M, Mirzaei PA, Bordbar H. Airborne and aerosol pathogen transmission modeling of respiratory events in buildings: An overview of computational fluid dynamics. Sustain Cities Soc 2022; 79:103704. [PMID: 35070645 PMCID: PMC8767784 DOI: 10.1016/j.scs.2022.103704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Revised: 01/13/2022] [Accepted: 01/15/2022] [Indexed: 05/03/2023]
Abstract
Pathogen droplets released from respiratory events are the primary means of dispersion and transmission of the recent pandemic of COVID-19. Computational fluid dynamics (CFD) has been widely employed as a fast, reliable, and inexpensive technique to support decision-making and to envisage mitigatory protocols. Nonetheless, the airborne pathogen droplet CFD modeling encounters limitations due to the oversimplification of involved physics and the intensive computational demand. Moreover, uncertainties in the collected clinical data required to simulate airborne and aerosol transport such as droplets' initial velocities, tempo-spatial profiles, release angle, and size distributions are broadly reported in the literature. There is a noticeable inconsistency around these collected data amongst many reported studies. This study aims to review the capabilities and limitations associated with CFD modeling. Setting the CFD models needs experimental data of respiratory flows such as velocity, particle size, and number distribution. Therefore, this paper briefly reviews the experimental techniques used to measure the characteristics of airborne pathogen droplet transmissions together with their limitations and reported uncertainties. The relevant clinical data related to pathogen transmission needed for postprocessing of CFD data and translating them to safety measures are also reviewed. Eventually, the uncertainty and inconsistency of the existing clinical data available for airborne pathogen CFD analysis are scurtinized to pave a pathway toward future studies ensuing these identified gaps and limitations.
Collapse
Affiliation(s)
- Yahya Sheikhnejad
- Centre for Mechanical Technology and Automation, Department of Mechanical Engineering, Universidade de Aveiro, Aveiro 3810-193, Portugal
- PICadvanced SA, Creative Science Park, Via do Conhecimento, Ed. Central, Ílhavo 3830-352, Portugal
| | - Reihaneh Aghamolaei
- School of Mechanical and Manufacturing Engineering, Faculty of Engineering and Computing, Dublin City University, Dublin 9, Whitehall, Ireland
| | - Marzieh Fallahpour
- School of Mechanical and Manufacturing Engineering, Faculty of Engineering and Computing, Dublin City University, Dublin 9, Whitehall, Ireland
| | - Hamid Motamedi
- Department of Mechanical Engineering, Tarbiat Modares University, Iran
| | - Mohammad Moshfeghi
- Department of Mechanical Engineering, Sogang University, Seoul, South Korea
| | - Parham A Mirzaei
- Architecture & Built Environment Department, University of Nottingham, University Park, Nottingham, UK
| | - Hadi Bordbar
- School of Engineering, Aalto University, Finland
| |
Collapse
|
8
|
Motamedi H, Shirzadi M, Tominaga Y, Mirzaei PA. CFD modeling of airborne pathogen transmission of COVID-19 in confined spaces under different ventilation strategies. Sustain Cities Soc 2022; 76:103397. [PMID: 34631393 PMCID: PMC8487408 DOI: 10.1016/j.scs.2021.103397] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 09/21/2021] [Accepted: 09/23/2021] [Indexed: 05/18/2023]
Abstract
Airborne transmission is an important route of spread of viral diseases (e.g., COVID-19) inside the confined spaces. In this respect, computational fluid dynamics (CFD) emerged as a reliable and fast tool to understand the complex flow patterns in such spaces. Most of the recent studies, nonetheless, focused on the spatial distribution of airborne pathogens to identify the infection probability without considering the exposure time. This research proposes a framework to evaluate the infection probability related to both spatial and temporal parameters. A validated Eulerian-Lagrangian CFD model of exhaled droplets is first developed and then evaluated with an office case study impacted by different ventilation strategies (i.e., cross- (CV), single- (SV), mechanical- (MV) and no-ventilation (NV)). CFD results were analyzed in a bespoke code to calculate the tempo-spatial distribution of accumulated airborne pathogens. Furthermore, two indices of local and general infection risks were used to evaluate the infection probability of the ventilation scenarios. The results suggest that SV has the highest infection probability while SV and NO result in higher dispersions of airborne pathogens inside the room. Eventually, the time history of indices reveals that the efficiency of CV and MV can be poor in certain regions of the room.
Collapse
Affiliation(s)
- Hamid Motamedi
- Department of Mechanical Engineering, Tarbiat Modares University, Iran
| | - Mohammadreza Shirzadi
- Wind and Fluid Engineering Research Center, Niigata Institute of Technology, Kashiwazaki, Japan
- Fine Particle Technology Laboratory, Graduate School of Advanced Science and Engineering, Hiroshima University, Higashi-Hiroshima, 739-8527, Hiroshima, Japan
| | - Yoshihide Tominaga
- Wind and Fluid Engineering Research Center, Niigata Institute of Technology, Kashiwazaki, Japan
| | - Parham A Mirzaei
- Architecture & Built Environment Department, University of Nottingham, University Park, Nottingham NG2RD, United Kingdom
| |
Collapse
|
9
|
Bueno de Mesquita PJ, Delp WW, Chan WR, Bahnfleth WP, Singer BC. Control of airborne infectious disease in buildings: Evidence and research priorities. Indoor Air 2022; 32:e12965. [PMID: 34816493 DOI: 10.1111/ina.12965] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 10/07/2021] [Accepted: 11/11/2021] [Indexed: 06/13/2023]
Abstract
The evolution of SARS-CoV-2 virus has resulted in variants likely to be more readily transmitted through respiratory aerosols, underscoring the increased potential for indoor environmental controls to mitigate risk. Use of tight-fitting face masks to trap infectious aerosol in exhaled breath and reduce inhalation exposure to contaminated air is of critical importance for disease control. Administrative controls including the regulation of occupancy and interpersonal spacing are also important, while presenting social and economic challenges. Indoor engineering controls including ventilation, exhaust, air flow control, filtration, and disinfection by germicidal ultraviolet irradiation can reduce reliance on stringent occupancy restrictions. However, the effects of controls-individually and in combination-on reducing infectious aerosol transfer indoors remain to be clearly characterized to the extent needed to support widespread implementation by building operators. We review aerobiologic and epidemiologic evidence of indoor environmental controls against transmission and present a quantitative aerosol transfer scenario illustrating relative differences in exposure at close-interactive, room, and building scales. We identify an overarching need for investment to implement building controls and evaluate their effectiveness on infection in well-characterized and real-world settings, supported by specific, methodological advances. Improved understanding of engineering control effectiveness guides implementation at scale while considering occupant comfort, operational challenges, and energy costs.
Collapse
Affiliation(s)
| | - William W Delp
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| | - Wanyu R Chan
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| | - William P Bahnfleth
- Department of Architectural Engineering, Pennsylvania State University, State College, Pennsylvania, USA
| | - Brett C Singer
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| |
Collapse
|
10
|
Bu Y, Ooka R, Kikumoto H, Oh W. Recent research on expiratory particles in respiratory viral infection and control strategies: A review. Sustain Cities Soc 2021; 73:103106. [PMID: 34306994 PMCID: PMC8272400 DOI: 10.1016/j.scs.2021.103106] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 06/07/2021] [Accepted: 06/15/2021] [Indexed: 05/15/2023]
Abstract
The global spread of coronavirus disease 2019 poses a significant threat to human health. In this study, recent research on the characteristics of expiratory particles and flow is reviewed, with a special focus on different respiratory activities, to provide guidance for reducing the viral infection risk in the built environment. Furthermore, environmental influence on particle evaporation, dispersion, and virus viability after exhalation and the current methods for infection risk assessment are reviewed. Finally, we summarize promising control strategies against infectious expiratory particles. The results show that airborne transmission is a significant viral transmission route, both in short and long ranges, from infected individuals. Relative humidity affects the evaporation and trajectories of middle-sized droplets most, and temperature accelerates the inactivation of SARS-CoV-2 both on surfaces and in aerosols. Future research is needed to improve infection risk models to better predict the infection potential of different transmission routes. Moreover, further quantitative studies on the expiratory flow features after wearing a mask are needed. Systematic investigations and the design of advanced air distribution methods, portable air cleaners, and ultraviolet germicidal irradiation systems, which have shown high efficacy in removing contaminants, are required to better control indoor viral infection.
Collapse
Affiliation(s)
- Yunchen Bu
- Graduate School of Engineering, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan
| | - Ryozo Ooka
- Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan
| | - Hideki Kikumoto
- Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan
| | - Wonseok Oh
- Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan
| |
Collapse
|
11
|
Kong X, Guo C, Lin Z, Duan S, He J, Ren Y, Ren J. Experimental study on the control effect of different ventilation systems on fine particles in a simulated hospital ward. Sustain Cities Soc 2021; 73:103102. [PMID: 34189016 PMCID: PMC8222082 DOI: 10.1016/j.scs.2021.103102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Revised: 06/12/2021] [Accepted: 06/14/2021] [Indexed: 05/03/2023]
Abstract
In recent years, a large number of respiratory infectious diseases (especially COVID-19) have broken out worldwide. Respiratory infectious viruses may be released in the air, resulting in cross-infection between patients and medical workers. Indoor ventilation systems can be adjusted to affect fine particles containing viruses. This study was aimed at performing a series of experiments to evaluate the ventilation performance and assess the exposure of healthcare workers (HW) to virus-laden particles released by patients in a confined experimental chamber. In a typical ward setting, four categories (top supply and exhaust, side supply and exhaust) were evaluated, encompassing 16 different air distribution patterns. The maximum reduction in the cumulative exposure level for HW was 70.8% in ventilation strategy D (upper diffusers on the sidewall supply and lower diffusers on the same sidewall return). The minimum value of the cumulative exposure level for a patient close to the source of the contamination pertained to Strategy E (upper diffusers on the sidewall supply and lower diffusers on the opposite sidewall return). Lateral ventilation strategies can provide significant guidance for ward operation to minimizing the airborne virus contamination. This study can provide a reference for sustainable buildings to construct a healthy indoor environment.
Collapse
Affiliation(s)
- Xiangfei Kong
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, China
| | - Chenli Guo
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, China
| | - Zhang Lin
- City University of Hong Kong Shenzhen Research Institute, Shenzhen, China
| | - Shasha Duan
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, China
| | - Junjie He
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, China
| | - Yue Ren
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, China
| | - Jianlin Ren
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, China
| |
Collapse
|
12
|
Elsaid AM, Ahmed MS. Indoor Air Quality Strategies for Air-Conditioning and Ventilation Systems with the Spread of the Global Coronavirus (COVID-19) Epidemic: Improvements and Recommendations. Environ Res 2021; 199:111314. [PMID: 34048748 PMCID: PMC8146370 DOI: 10.1016/j.envres.2021.111314] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Accepted: 05/06/2021] [Indexed: 05/08/2023]
Abstract
The coronavirus has come to the world and spread with great wide among the countries of the world and has resulted in numerous infections that exceeded 167,181,023 million patients and are close to 3.5 deaths by September 2021. It also brought with it panic and fear, halted many activities, and led to the decline of the global economy. It changed human behavior and forced people to change their lifestyles to avoid infection. One of the most sectors that must be taken into consideration through pandemic coronavirus (COVID-19) around the globe is the air conditioning systems. The HVAC systems depend on the air as a heat transfer medium. The air contains a group of pollutants, viruses, and bacteria, and it affects and destroys human life. The air filter plays a major role as an important component in the air conditioning systems. Thus, it requires more effort by researchers to improve its design to prevent the ultra-size of particles loaded with coronavirus (COVID-19). This paper provides insight into the design of existing combined air-conditioners on their suitability and their impact on the spread of the hybrid coronavirus epidemic and review efforts to obtain a highly efficient air filter to get rid of super-sized particles for protection against epidemic infection. In addition, important guideline recommendations have been made to limit the spread of the COVID-19 virus and to obtain indoor air quality in air-conditioned places.
Collapse
Affiliation(s)
- Ashraf Mimi Elsaid
- RHVAC Department of Technology, Faculty of Technology and Education, Helwan University, Cairo, 11282, Egypt.
| | - M Salem Ahmed
- Mechanical Power Engineering Department, Faculty of Technology and Education, Sohag University, Egypt
| |
Collapse
|
13
|
He R, Liu W, Elson J, Vogt R, Maranville C, Hong J. Airborne transmission of COVID-19 and mitigation using box fan air cleaners in a poorly ventilated classroom. Phys Fluids (1994) 2021; 33:057107. [PMID: 34040337 PMCID: PMC8142835 DOI: 10.1063/5.0050058] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Accepted: 04/02/2021] [Indexed: 05/04/2023]
Abstract
Many indoor places, including aged classrooms and offices, prisons, homeless shelters, etc., are poorly ventilated but resource-limited to afford expensive ventilation upgrades or commercial air purification systems, raising concerns on the safety of opening activities in these places in the era of the COVID-19 pandemic. To address this challenge, using computational fluid dynamics, we conducted a systematic investigation of airborne transmission in a classroom equipped with a single horizontal unit ventilator (HUV) and evaluate the performance of a low-cost box fan air cleaner for risk mitigation. Our study shows that placing box fan air cleaners in the classroom results in a substantial reduction of airborne transmission risk across the entire space. The air cleaner can achieve optimal performance when placed near the asymptomatic patient. However, without knowing the location of the patient, the performance of the cleaner is optimal near the HUV with the air flowing downwards. In addition, we find that it is more efficient in reducing aerosol concentration and spread in the classroom by adding air cleaners in comparison with raising the flow rate of HUV alone. The number and placement of air cleaners need to be adjusted to maintain their efficacy for larger classrooms and to account for the thermal gradient associated with a human thermal plume and hot ventilation air during cold seasons. Overall, our study shows that box fan air cleaners can serve as an effective low-cost alternative for mitigating airborne transmission risks in poorly ventilated spaces.
Collapse
Affiliation(s)
| | - Wanjiao Liu
- Research and Advanced Engineering, Ford Motor Company, 2101 Village Road, Dearborn, Michigan 48121, USA
| | - John Elson
- Research and Advanced Engineering, Ford Motor Company, 2101 Village Road, Dearborn, Michigan 48121, USA
| | - Rainer Vogt
- Ford-Werke GmbH, Research & Innovation Center, 52072 Aachen, Germany
| | - Clay Maranville
- Research and Advanced Engineering, Ford Motor Company, 2101 Village Road, Dearborn, Michigan 48121, USA
| | - Jiarong Hong
- Author to whom correspondence should be addressed:
| |
Collapse
|
14
|
Alaidroos A, Almaimani A, Baik A, Al-Amodi M, Rahaman KR. Are Historical Buildings More Adaptive to Minimize the Risks of Airborne Transmission of Viruses and Public Health? A Study of the Hazzazi House in Jeddah (Saudi Arabia). Int J Environ Res Public Health 2021; 18:3601. [PMID: 33808481 PMCID: PMC8037546 DOI: 10.3390/ijerph18073601] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 03/23/2021] [Accepted: 03/26/2021] [Indexed: 11/16/2022]
Abstract
The coronavirus (COVID-19) pandemic has brought immense challenges to the natural and built environment to develop an antivirus-enabled model for reducing potential risks of spreading the virus at varied scales such as buildings, neighborhoods, and cities. Spatial configurations of structures may hinder or assist the spread of viruses in the built environment. In this study, we have hypothesized that suitable air ventilation in historic buildings may enhance the built environment to combat the spreading of infectious viruses. To provide such quantitative shreds of evidence, we have generated and estimated an integrated model to summarize obtained information by considering natural ventilation, wind speed, inflow and outflow, wind direction, and forecasting the associated risks of airborne disease transmission in a historical building (i.e., the Hazzazi House in particular). Intrinsically, the results have demonstrated that the effectiveness of natural ventilation has directly influenced reducing the risks of transmitting airborne infectious viruses for the selected heritage building in Jeddah (Saudi Arabia). The adopted methods in this research may be useful to understand the potentials of conserving old heritage buildings. Consequently, the results demonstrate that natural air ventilation systems are critical to combat the spread of infectious diseases in the pandemic.
Collapse
Affiliation(s)
- Alaa Alaidroos
- Architectural Engineering Department, Collage of Engineering, King Abdulaziz University KAU-Rabigh, Rabigh 25732, Saudi Arabia;
| | - Ayad Almaimani
- Architecture Department, Faculty of Architecture and Planning, King Abdulaziz University (KAU), Jeddah 21589, Saudi Arabia; (A.A.); (M.A.-A.)
| | - Ahmed Baik
- Geomatics Department, Faculty of Architecture and Planning, King Abdulaziz University (KAU), Jeddah 21589, Saudi Arabia;
| | - Mohamed Al-Amodi
- Architecture Department, Faculty of Architecture and Planning, King Abdulaziz University (KAU), Jeddah 21589, Saudi Arabia; (A.A.); (M.A.-A.)
| | - Khan Rubayet Rahaman
- Department of Geography and Environment Studies, St. Mary’s University, Halifax, NS B3H 3C3, Canada
| |
Collapse
|
15
|
Zhou M, Zou J. A dynamical overview of droplets in the transmission of respiratory infectious diseases. Phys Fluids (1994) 2021; 33:031301. [PMID: 33897237 PMCID: PMC8061903 DOI: 10.1063/5.0039487] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Accepted: 12/29/2020] [Indexed: 05/04/2023]
Abstract
The outbreak of the coronavirus disease has drawn public attention to the transmission of infectious pathogens, and as major carriers of those pathogens, respiratory droplets play an important role in the process of transmission. This Review describes respiratory droplets from a physical and mechanical perspective, especially their correlation with the transmission of infectious pathogens. It covers the important aspects of (i) the generation and expulsion of droplets during respiratory activities, (ii) the transport and evolution of respiratory droplets in the ambient environment, and (iii) the inhalation and deposition of droplets in the human respiratory tract. State-of-the-art experimental, computational, and theoretical models and results are presented, and the corresponding knowledge gaps are identified. This Review stresses the multidisciplinary nature of its subject and appeals for collaboration among different fields to fight the present pandemic.
Collapse
Affiliation(s)
- Maoying Zhou
- School of Mechanical Engineering, Hangzhou Dianzi
University, Hangzhou, Zhejiang 310027, China
| | - Jun Zou
- State Key Laboratory of Fluid Power and Mechatronic Systems,
Zhejiang University, Hangzhou, Zhejiang 310027,
China
| |
Collapse
|
16
|
Alsaad H, Voelker C. Could the ductless personalized ventilation be an alternative to the regular ducted personalized ventilation? Indoor Air 2021; 31:99-111. [PMID: 32681676 DOI: 10.1111/ina.12720] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 07/07/2020] [Accepted: 07/13/2020] [Indexed: 06/11/2023]
Abstract
This study investigates the performance of two systems: personalized ventilation (PV) and ductless personalized ventilation (DPV). Even though the literature indicates a compelling performance of PV, it is not often used in practice due to its impracticality. Therefore, the present study assesses the possibility of replacing the inflexible PV with DPV in office rooms equipped with displacement ventilation (DV) in the summer season. Numerical simulations were utilized to evaluate the inhaled concentration of pollutants when PV and DPV are used. The systems were compared in a simulated office with two occupants: a susceptible occupant and a source occupant. Three types of pollution were simulated: exhaled infectious air, dermally emitted contamination, and room contamination from a passive source. Results indicated that PV improved the inhaled air quality regardless of the location of the pollution source; a higher PV supply flow rate positively impacted the inhaled air quality. Contrarily, the performance of DPV was highly sensitive to the source location and the personalized flow rate. A higher DPV flow rate tends to decrease the inhaled air quality due to increased mixing of pollutants in the room. Moreover, both systems achieved better results when the personalized system of the source occupant was switched off.
Collapse
Affiliation(s)
- Hayder Alsaad
- Department of Building Physics, Bauhaus-Universität Weimar, Weimar, Germany
| | - Conrad Voelker
- Department of Building Physics, Bauhaus-Universität Weimar, Weimar, Germany
| |
Collapse
|
17
|
Affiliation(s)
- Arsen K Melikov
- International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Kgs. Lyngby, Denmark
| |
Collapse
|
18
|
Morawska L, Tang JW, Bahnfleth W, Bluyssen PM, Boerstra A, Buonanno G, Cao J, Dancer S, Floto A, Franchimon F, Haworth C, Hogeling J, Isaxon C, Jimenez JL, Kurnitski J, Li Y, Loomans M, Marks G, Marr LC, Mazzarella L, Melikov AK, Miller S, Milton DK, Nazaroff W, Nielsen PV, Noakes C, Peccia J, Querol X, Sekhar C, Seppänen O, Tanabe SI, Tellier R, Tham KW, Wargocki P, Wierzbicka A, Yao M. How can airborne transmission of COVID-19 indoors be minimised? Environ Int 2020; 142:105832. [PMID: 32521345 PMCID: PMC7250761 DOI: 10.1016/j.envint.2020.105832] [Citation(s) in RCA: 544] [Impact Index Per Article: 136.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 05/21/2020] [Accepted: 05/21/2020] [Indexed: 05/17/2023]
Abstract
During the rapid rise in COVID-19 illnesses and deaths globally, and notwithstanding recommended precautions, questions are voiced about routes of transmission for this pandemic disease. Inhaling small airborne droplets is probable as a third route of infection, in addition to more widely recognized transmission via larger respiratory droplets and direct contact with infected people or contaminated surfaces. While uncertainties remain regarding the relative contributions of the different transmission pathways, we argue that existing evidence is sufficiently strong to warrant engineering controls targeting airborne transmission as part of an overall strategy to limit infection risk indoors. Appropriate building engineering controls include sufficient and effective ventilation, possibly enhanced by particle filtration and air disinfection, avoiding air recirculation and avoiding overcrowding. Often, such measures can be easily implemented and without much cost, but if only they are recognised as significant in contributing to infection control goals. We believe that the use of engineering controls in public buildings, including hospitals, shops, offices, schools, kindergartens, libraries, restaurants, cruise ships, elevators, conference rooms or public transport, in parallel with effective application of other controls (including isolation and quarantine, social distancing and hand hygiene), would be an additional important measure globally to reduce the likelihood of transmission and thereby protect healthcare workers, patients and the general public.
Collapse
Affiliation(s)
- Lidia Morawska
- International Laboratory for Air Quality and Heath (ILAQH), WHO Collaborating Centre for Air Quality and Health, School of Earth and Atmospheric Sciences, Queensland University of Technology, Brisbane, Queensland, Australia.
| | - Julian W Tang
- Respiratory Sciences, University of Leicester, Leicester, United Kingdom
| | - William Bahnfleth
- Department of Architectural Engineering, The Pennsylvania State University, USA
| | - Philomena M Bluyssen
- Faculty of Architecture and the Built Environment, Delft University of Technology, the Netherlands
| | - Atze Boerstra
- REHVA (Federation of European Heating, Ventilation and Air Conditioning Associations), BBA Binnenmilieu, the Netherlands
| | - Giorgio Buonanno
- Department if Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, Italy
| | - Junji Cao
- Key Lab of Aerosol Chemistry and Physics Chinese Academy of Sciences, Xi'an, Beijing, China
| | - Stephanie Dancer
- Edinburgh Napier University and NHS Lanarkshire, Scotland, United Kingdom
| | - Andres Floto
- Department of Medicine, University of Cambridge, United Kingdom
| | | | - Charles Haworth
- Cambridge Centre for Lung Infection, Royal Papworth Hospital and Department of Medicine, University of Cambridge, Cambridge, United Kingdom
| | - Jaap Hogeling
- International Standards at ISSO, ISSO International Project, the Netherlands
| | | | - Jose L Jimenez
- Department of Chemistry, and Cooperative Institute for Research in Environmental Sciences (CIRES) University of Colorado, Boulder, USA
| | - Jarek Kurnitski
- REHVA Technology and Research Committee, Tallinn University of Technology, Estonia
| | - Yuguo Li
- Department of Mechancal Engineering, Hong Kong University, University of Hong Kong, Pokfulam, Hong Kong, China
| | - Marcel Loomans
- Department of the Built Environment, Eindhoven University of Technology (TU/e), the Netherlands
| | - Guy Marks
- Centre for Air quality Research and evaluation (CAR), University of New South Wales (UNSW), Sydney, New South Wales, Australia
| | | | | | - Arsen Krikor Melikov
- International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Denmark
| | - Shelly Miller
- Mechanical Engineering, University of Colorado, Boulder, USA
| | - Donald K Milton
- Environmental Health, School of Public Health, University of Maryland, USA
| | - William Nazaroff
- Department of Civil and Environmental Engineering, University of California, Berkeley, CA, USA
| | - Peter V Nielsen
- Faculty of Engineering and Science, Department of Civil Engineering, Aalborg University, Denmark
| | - Catherine Noakes
- School of Civil Engineering, University of Leeds, United Kingdom
| | | | - Xavier Querol
- Institute of Environmental Assessment and Water Research, Department of Geosciences, Spanish National Research Council, Barcelona, Spain
| | - Chandra Sekhar
- Department of Building, National University of Singapore, Singapore
| | | | | | | | - Kwok Wai Tham
- Department of Building, National University of Singapore, Singapore
| | - Pawel Wargocki
- International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Denmark
| | | | - Maosheng Yao
- College of Environmental Sciences and Engineering, Peking University, Beijing, China
| |
Collapse
|
19
|
Zhao X, Shi Z, Chen Q. Inverse design of an indoor environment using a filter-based topology method with experimental verification. Indoor Air 2020; 30:1039-1051. [PMID: 32092184 DOI: 10.1111/ina.12661] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2019] [Revised: 01/22/2020] [Accepted: 02/21/2020] [Indexed: 06/10/2023]
Abstract
In order to create a healthy, comfortable, productive, and energy-efficient indoor environment, the computational fluid dynamics (CFD)-based adjoint method with an area-constrained topology method can be used to inversely design the optimal number, size, location, and shape of air supply inlets and air supply parameters. However, this method is not very mature, and the distribution of retained inlets is always scattered. To solve that problem, this investigation introduced a filter method that smooths the intermediate results during the inverse design process. Using a three-dimensional, non-isothermal, asymmetrical office with pre-set air supply inlets as an example, this study verified the performance of the proposed filter-based topology method. The verified method was then used to solve a multi-objective design problem and design an optimal indoor environment for a room. The results indicate that the proposed method was able to find the optimal number, location, and shape of air supply inlets and the optimal air supply temperature, velocity, and angle that led to a thermally comfortable, healthy, productive, and energy-efficient indoor environment. Finally, this investigation installed the optimal inlets in an environmental chamber to mimic the room. The measured air temperature, velocity, and mean age of air in several typical locations in the environmental chamber matched the CFD simulation results very closely.
Collapse
Affiliation(s)
- Xingwang Zhao
- Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China
- School of Mechanical Engineering, Purdue University, West Lafayette, IN, USA
| | - Zhu Shi
- School of Mechanical Engineering, Purdue University, West Lafayette, IN, USA
| | - Qingyan Chen
- School of Mechanical Engineering, Purdue University, West Lafayette, IN, USA
| |
Collapse
|
20
|
Liu, Zhu, Kim, Srebric. A Review of CFD Analysis Methods for Personalized Ventilation (PV) in Indoor Built Environments. Sustainability 2019; 11:4166. [DOI: 10.3390/su11154166] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Computational fluid dynamics (CFD) is an effective analysis method of personalized ventilation (PV) in indoor built environments. As an increasingly important supplement to experimental and theoretical methods, the quality of CFD simulations must be maintained through an adequately controlled numerical modeling process. CFD numerical data can explain PV performance in terms of inhaled air quality, occupants’ thermal comfort, and building energy savings. Therefore, this paper presents state-of-the-art CFD analyses of PV systems in indoor built environments. The results emphasize the importance of accurate thermal boundary conditions for computational thermal manikins (CTMs) to properly analyze the heat exchange between human body and the microenvironment, including both convective and radiative heat exchange. CFD modeling performance is examined in terms of effectiveness of computational grids, convergence criteria, and validation methods. Additionally, indices of PV performance are suggested as system-performance evaluation criteria. A specific utilization of realistic PV air supply diffuser configurations remains a challenging task for further study. Overall, the adaptable airflow characteristics of a PV air supply provide an opportunity to achieve better thermal comfort with lower energy use based on CFD numerical analyses.
Collapse
|
21
|
Abstract
Using personalized ventilation systems in office buildings, important energy saving might be obtained, which may improve the indoor air quality and thermal comfort sensation of occupants at the same time. In this paper, the operation testing results of an advanced personalized ventilation system are presented. Eleven different air terminal devices were analyzed. Based on the obtained air velocities and turbulence intensities, one was chosen to perform thermal comfort experiments with subjects. It was shown that, in the case of elevated indoor temperatures, the thermal comfort sensation can be improved considerably. A series of measurements were carried out in order to determine the background noise level and the noise generated by the personalized ventilation system. It was shown that further developments of the air distribution system are needed.
Collapse
|
22
|
Kabanshi A, Sandberg M. Entrainment and its implications on microclimate ventilation systems: Scaling the velocity and temperature field of a round free jet. Indoor Air 2019; 29:331-346. [PMID: 30500986 DOI: 10.1111/ina.12524] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Revised: 11/23/2018] [Accepted: 11/24/2018] [Indexed: 06/09/2023]
Abstract
Research on microclimate ventilation systems, which mostly involve free jets, points to delivery of better ventilation in breathing zones. While the literature is comprehensive, the influence of contaminant entrainment in jet flows and its implications on the delivery of supplied air is not fully addressed. This paper presents and discusses entrainment characteristics of a jet issued from a round nozzle (0.05 m diameter), in relation to ventilation, by exploring the velocity and temperature fields of the jet flow. The results show a trend suggesting that increasing the Reynold number (Re) reduces ambient entrainment. As shown herein, about 30% concentration of ambient air entrained into the bulk jet flow at Re 2541 while Re 9233 had about 13% and 19% for Re = 6537/12 026 at downstream distance of 8 diameters (40 cm). The study discusses that "moderate to high" Re may be ideal to reduce contaminant entrainment, but this is limited by delivery distance and possibly the risk of occupant discomfort. Incorporating the entrainment mixing factor (the ratio of room contaminants entrained into a jet flow) in performance measurements is proposed, and further studies are recommended to verify results herein and test whether this is general to other nozzle configurations.
Collapse
Affiliation(s)
- Alan Kabanshi
- Department of Building, Energy and Environmental Engineering, University of Gävle, Gävle, Sweden
| | - Mats Sandberg
- Department of Building, Energy and Environmental Engineering, University of Gävle, Gävle, Sweden
| |
Collapse
|
23
|
Ai ZT, Melikov AK. Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review. Indoor Air 2018; 28:500-524. [PMID: 29683213 DOI: 10.1111/ina.12465] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2017] [Accepted: 04/13/2018] [Indexed: 05/04/2023]
Abstract
This article reviews past studies of airborne transmission between occupants in indoor environments, focusing on the spread of expiratory droplet nuclei from mouth/nose to mouth/nose for non-specific diseases. Special attention is paid to summarizing what is known about the influential factors, the inappropriate simplifications of the thermofluid boundary conditions of thermal manikins, the challenges facing the available experimental techniques, and the limitations of available evaluation methods. Secondary issues are highlighted, and some new ways to improve our understanding of airborne transmission indoors are provided. The characteristics of airborne spread of expiratory droplet nuclei between occupants, which are influenced correlatively by both environmental and personal factors, were widely revealed under steady-state conditions. Owing to the different boundary conditions used, some inconsistent findings on specific influential factors have been published. The available instrumentation was too slow to provide accurate concentration profiles for time-dependent evaluations of events with obvious time characteristics, while computational fluid dynamics (CFD) studies were mainly performed in the framework of inherently steady Reynolds-averaged Navier-Stokes modeling. Future research needs in 3 areas are identified: the importance of the direction of indoor airflow patterns, the dynamics of airborne transmission, and the application of CFD simulations.
Collapse
Affiliation(s)
- Z T Ai
- Department of Civil Engineering, International Centre for Indoor Environment and Energy, Technical University of Denmark, Copenhagen, Denmark
| | - A K Melikov
- Department of Civil Engineering, International Centre for Indoor Environment and Energy, Technical University of Denmark, Copenhagen, Denmark
| |
Collapse
|
24
|
Lan L, Qian XL, Lian ZW, Lin YB. Local body cooling to improve sleep quality and thermal comfort in a hot environment. Indoor Air 2018; 28:135-145. [PMID: 28960513 DOI: 10.1111/ina.12428] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2017] [Accepted: 09/22/2017] [Indexed: 05/14/2023]
Abstract
The effects of local body cooling on thermal comfort and sleep quality in a hot environment were investigated in an experiment with 16 male subjects. Sleep quality was evaluated subjectively, using questionnaires completed in the morning, and objectively, by analysis of electroencephalogram (EEG) signals that were continuously monitored during the sleeping period. Compared with no cooling, the largest improvement in thermal comfort and sleep quality was observed when the back and head (neck) were both cooled at a room temperature of 32°C. Back cooling alone also improved thermal comfort and sleep quality, although the effects were less than when cooling both back and head (neck). Mean sleep efficiency was improved from 84.6% in the no cooling condition to 95.3% and 92.8%, respectively, in these conditions, indicating good sleep quality. Head (neck) cooling alone slightly improved thermal comfort and subjective sleep quality and increased Stage N3 sleep, but did not otherwise improve sleep quality. The results show that local cooling applied to large body sections (back and head) could effectively maintain good sleep and improve thermal comfort in a hot environment.
Collapse
Affiliation(s)
- L Lan
- Department of Architecture, School of Naval Architecture, Ocean & Civil Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - X L Qian
- Department of Architecture, School of Naval Architecture, Ocean & Civil Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Z W Lian
- Department of Architecture, School of Naval Architecture, Ocean & Civil Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Y B Lin
- The Third Shanghai People's Hospital, Shanghai, China
| |
Collapse
|
25
|
Bivolarova M, Ondráček J, Melikov A, Ždímal V. A comparison between tracer gas and aerosol particles distribution indoors: The impact of ventilation rate, interaction of airflows, and presence of objects. Indoor Air 2017; 27:1201-1212. [PMID: 28378912 DOI: 10.1111/ina.12388] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Accepted: 04/02/2017] [Indexed: 05/07/2023]
Abstract
The study investigated the separate and combined effects of ventilation rate, free convection flow produced by a thermal manikin, and the presence of objects on the distribution of tracer gas and particles in indoor air. The concentration of aerosol particles and tracer gas was measured in a test room with mixing ventilation. Three layouts were arranged: an empty room, an office room with an occupant sitting in front of a table, and a single-bed hospital room. The room occupant was simulated by a thermal manikin. Monodisperse particles of three sizes (0.07, 0.7, and 3.5 μm) and nitrous oxide tracer gas were generated simultaneously at the same location in the room. The particles and gas concentrations were measured in the bulk room air, in the breathing zone of the manikin, and in the exhaust air. Within the breathing zone of the sitting occupant, the tracer gas emerged as reliable predictor for the exposure to all different-sized test particles. A change in the ventilation rate did not affect the difference in concentration distribution between tracer gas and larger particle sizes. Increasing the room surface area did not influence the similarity in the dispersion of the aerosol particles and the tracer gas.
Collapse
Affiliation(s)
- M Bivolarova
- Department of Civil Engineering, International Centre for Indoor Environment and Energy, Technical University of Denmark, Lyngby, Denmark
| | - J Ondráček
- Laboratory of Aerosol Chemistry and Physics, Institute of Chemical Process Fundamentals of the CAS, Prague, Czech Republic
| | - A Melikov
- Department of Civil Engineering, International Centre for Indoor Environment and Energy, Technical University of Denmark, Lyngby, Denmark
| | - V Ždímal
- Laboratory of Aerosol Chemistry and Physics, Institute of Chemical Process Fundamentals of the CAS, Prague, Czech Republic
| |
Collapse
|
26
|
Habchi C, Ghali K, Ghaddar N. Transient transport model of particles resulting from high momentum respiratory activities: Inter-personal exposure. Build Environ 2015; 94:54-67. [PMID: 32288033 PMCID: PMC7125956 DOI: 10.1016/j.buildenv.2015.07.028] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2015] [Revised: 06/19/2015] [Accepted: 07/28/2015] [Indexed: 05/12/2023]
Abstract
In this work, a transient mathematical multi-region zonal transport model of particle behavior resulting from high momentum respiratory activities (HMRA) is developed focusing on the transient inter-personal exposure (IPE) in indoor spaces ventilated by displacement ventilation (DV) systems. The developed model was validated by experimentation and by published empirical data. Three stages are identified with respect to time for the variation of the IPE: a first stage dominated by the propagation and decay of the exhaled jet, a particles' redistribution stage, and a particles' removal stage. The inhaled dose is affected by the DV flow rate, cough velocity, particle diameter and distance between the occupants. The DV system with a flow rate of 100 L/s reduced significantly the inhaled dose during particle redistribution and removal stages decreasing the total inhaled dose by 83% compared to a flow rate of 50 L/s. IPE is higher when particle diameter is increased from 1 to 20 μm due to the opposition of particle removal by the upward DV. A comparison between steady and transient modeling of the IPE showed that steady modeling captures the physics affecting particle spread due to HMRA but it over-predicts the inhaled dose. It is found that for a DV flow rate of 100 L/s and a cough velocity of 22 m/s during 1 s, and 1 μm particles, the minimum required distance between the occupants for a threshold inhaled dose of 10-5 kg is nearly 0.5 m by transient modeling while it is 2.15 m by steady state modeling.
Collapse
Affiliation(s)
- Carine Habchi
- Mechanical Engineering Department, American University of Beirut, P.O. Box 11-0236, Beirut 1107-2020, Lebanon
| | - Kamel Ghali
- Mechanical Engineering Department, American University of Beirut, P.O. Box 11-0236, Beirut 1107-2020, Lebanon
| | - Nesreen Ghaddar
- Mechanical Engineering Department, American University of Beirut, P.O. Box 11-0236, Beirut 1107-2020, Lebanon
| |
Collapse
|
27
|
MacNaughton P, Pegues J, Satish U, Santanam S, Spengler J, Allen J. Economic, Environmental and Health Implications of Enhanced Ventilation in Office Buildings. Int J Environ Res Public Health 2015; 12:14709-22. [PMID: 26593933 PMCID: PMC4661675 DOI: 10.3390/ijerph121114709] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2015] [Revised: 10/22/2015] [Accepted: 10/30/2015] [Indexed: 12/05/2022]
Abstract
Introduction: Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoption—Economic and environmental costs. Methods: We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person), 30% enhanced ventilation, and 40 cfm/person) and four different heating, ventilation and air conditioning (HVAC) system strategies (Variable Air Volume (VAV) with reheat and a Fan Coil Unit (FCU), both with and without an energy recovery ventilator). We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Results: Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than $40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities). The same change in ventilation improved the performance of workers by 8%, equivalent to a $6500 increase in employee productivity each year. Reduced absenteeism and improved health are also seen with enhanced ventilation. Conclusions: The health benefits associated with enhanced ventilation rates far exceed the per-person energy costs relative to salary costs. Environmental impacts can be mitigated at regional, building, and individual-level scales through the transition to renewable energy sources, adoption of energy efficient systems and ventilation strategies, and promotion of other sustainable policies.
Collapse
Affiliation(s)
- Piers MacNaughton
- Department of Environmental Health, Harvard T.H. Chan School of Public Health, Landmark 409 West, 401 Park Drive Boston, MA 02115, USA.
| | - James Pegues
- United Technologies Climate, Controls & Security, Syracuse, NY 13221, USA.
| | - Usha Satish
- Psychiatry and Behavioral Sciences, SUNY-Upstate Medical School, Syracuse, NY 13210, USA.
| | - Suresh Santanam
- Industrial Assessment Center, Biomedical and Chemical Engineering Department, Syracuse University, Syracuse, NY 13210, USA.
| | - John Spengler
- Department of Environmental Health, Harvard T.H. Chan School of Public Health, Landmark 409 West, 401 Park Drive Boston, MA 02115, USA.
| | - Joseph Allen
- Department of Environmental Health, Harvard T.H. Chan School of Public Health, Landmark 409 West, 401 Park Drive Boston, MA 02115, USA.
| |
Collapse
|