1
|
Uysal H, Senturk H, Calim M, Daskaya H, Guney IA, Karaaslan K. Comparison of LMA® gastro airway and gastro-laryngeal tube in endoscopic retrograde cholangiopancreatography: a prospective randomized observational trial. Minerva Anestesiol 2021; 87:987-996. [PMID: 33982986 DOI: 10.23736/s0375-9393.21.15371-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND New generation airway devices with different designs have been developed as an alternative to endotracheal intubation in order to avoid adverse events associated with sedation in endoscopic procedures and to provide patent airway. We aimed to compare two supraglottic airway devices (SGADs), the LMA®GastroTM Airway and Gastro Laryngeal Tube (GLT), in terms of airway efficiency, performance during procedure and adverse events in Endoscopic Retrograde Cholangiopancreatography (ERCP). METHODS A hundred-three ERCP patients without high risk of aspiration were included. Patients were randomly allocated to the LMA Gastro and GLT groups. The primary study outcomes were the comparison of the two SGADs in terms of oropharyngeal leak pressure (OLP). Secondary study outcome was SGADs-related adverse events. RESULTS Procedures were completed with SGADs in fifty patients in each group. The rate of successful insertion at first attempt was 72% in GLT and 96% in LMA Gastro (p=0.004). The mean OLP of LMA Gastro Group (31.8cm H2O) was significantly higher than that of the GLT Group (26.5cm H2O), (p=0.0001). However endoscopists' satisfaction was higher in GLT (p=0.0001). Mucosal damage and sore throat were lower in LMA Gastro Group. CONCLUSIONS LMA® Gastro™ had a higher OLP than GLT. However, GLT was better for endoscopist satisfaction, as it provides more satisfying maneuverability. As to secondary outcome advers events were lower in LMA® Gastro™. The lower complication rates associated with the device and providing a more patent airway also highlighted the apparent clinical efficacy of LMA® Gastro™ than GLT, in ERCP.
Collapse
Affiliation(s)
- Harun Uysal
- Department of Anesthesiology and Reanimation, Bezmialem Vakif University Medical Faculty, Istanbul, Turkey -
| | - Hakan Senturk
- Department of Gastroenterology and Hepatology, Bezmialem Vakif University Medical Faculty, Istanbul, Turkey
| | - Muhittin Calim
- Department of Anesthesiology and Reanimation, Bezmialem Vakif University Medical Faculty, Istanbul, Turkey
| | - Hayrettin Daskaya
- Department of Anesthesiology and Reanimation, Bezmialem Vakif University Medical Faculty, Istanbul, Turkey
| | - Ibrahim A Guney
- Department of Anesthesiology and Reanimation, Bezmialem Vakif University Medical Faculty, Istanbul, Turkey
| | - Kazim Karaaslan
- Department of Anesthesiology and Reanimation, Bezmialem Vakif University Medical Faculty, Istanbul, Turkey
| |
Collapse
|
2
|
Eglen M, Kuvaki B, Günenç F, Ozbilgin S, Küçükgüçlü S, Polat E, Pekel E. [Comparison of three different insertion techniques with LMA-Unique™ in adults: results of a randomized trial]. Rev Bras Anestesiol 2017; 67:521-526. [PMID: 28526466 DOI: 10.1016/j.bjan.2017.04.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2015] [Accepted: 07/13/2016] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND The triple airway maneuver insertion technique allowed faster insertion of the LMA. This study compared three different insertion techniques of the laryngeal mask airway-Unique™. METHODS One hundred and eighty ASA I-II patients aged 18-65 years were included into the study. Patients were randomly allocated to the standard, rotational and triple airway maneuver (triple) group. In the standard group (n=60), the LMA (Laryngeal Mask Airway) was inserted with digital intraoral manipulation. In the triple group (n=60), the LMA was inserted with triple airway maneuver (mouth opening, head extension and jaw thrust). In the rotational group (n=60), LMA was inserted back-to-front, like a Guedel airway. Successful insertion at first attempt, time for successful insertion, fiber optic assessment, airway morbidity and hemodynamic responses were assessed. RESULTS Successful insertion at the first attempt was 88.3% for the standard, 78.3% for the rotational and 88.3% for the triple group. Overall success rate (defined as successful insertion at first and second attempt) was 93% for the standard, 90% for the rotational and 95% for the triple group. Time for successful insertion was significantly shorter in the triple group (mean [range] 8.63 [5-19]s) compared with the standard (11.78 [6-24]s) and rotational group (11.57 [5-31]s). Fiber optic assessment, airway morbidity and hemodynamic responses were similar in all groups. CONCLUSIONS Rotational and triple airway maneuver insertion techniques are acceptable alternatives. Triple airway maneuver technique shows higher overall success rates and allows shorter insertion time for LMA insertion and should therefore be kept in mind for emergent situations.
Collapse
Affiliation(s)
- Merih Eglen
- Malatya State Hospital, Department of Anesthesiology and Intensive Care, Malatya, Turquia
| | - Bahar Kuvaki
- Dokuz Eylül University, Medical Faculty, Department of Anesthesiology and Intensive Care, İzmir, Turquia
| | - Ferim Günenç
- Dokuz Eylül University, Medical Faculty, Department of Anesthesiology and Intensive Care, İzmir, Turquia
| | - Sule Ozbilgin
- Dokuz Eylül University, Medical Faculty, Department of Anesthesiology and Intensive Care, İzmir, Turquia.
| | - Semih Küçükgüçlü
- Dokuz Eylül University, Medical Faculty, Department of Anesthesiology and Intensive Care, İzmir, Turquia
| | - Ebru Polat
- Samsun State Hospital, Department of Anesthesiology and Intensive Care, Samsun, Turquia
| | - Emel Pekel
- Florence Nighthingale Hospital, Department of Anesthesiology and Intensive Care, İstanbul, Turquia
| |
Collapse
|
3
|
Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults. Anesthesiol Res Pract 2012; 2012:405812. [PMID: 22505884 PMCID: PMC3299248 DOI: 10.1155/2012/405812] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2011] [Revised: 12/21/2011] [Accepted: 12/23/2011] [Indexed: 12/15/2022] Open
Abstract
We conducted a randomised single-blind controlled trial comparing the LMA-Unique (LMAU) and the AMBU AuraOnce (AMBU) disposable laryngeal mask in spontaneously breathing adult patients undergoing general anaesthesia. Eighty-two adult patients (ASA status I–IV) were randomly allocated to receive the LMAU or AMBU and were blinded to device selection. Patients received a standardized anesthetic and all airway devices were inserted by trained anaesthetists. Size selection was guided by manufacturer recommendations. All data were collected by a single, unblinded observer. When compared with the LMAU, the AMBU produced significantly higher airway sealing pressures (AMBU 20 ± 6; LMAU 15 ± 7 cm H2O; P = 0.001). There was no statistical difference between the two devices for overall success rate, insertion time, number of adjustments, laryngeal alignment, blood-staining, and sore throat (P ≥ 0.05). The AMBU AuraOnce disposable laryngeal mask provided a higher oropharyngeal leak pressure compared to the LMA Unique in spontaneously breathing adult patients.
Collapse
|
4
|
Kim SH, Choi EM, Chang CH, Kim HK, Chung MH, Choi YR. Comparison of the effect-site concentrations of remifentanil for Streamlined Liner of the Pharynx Airway (SLIPA) versus laryngeal mask airway SoftSealTM insertion during target-controlled infusion of propofol. Anaesth Intensive Care 2011; 39:611-7. [PMID: 21823378 DOI: 10.1177/0310057x1103900412] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
This study was designed to determine the optimal dose of remifentanil required for the successful insertion of Streamlined Liner of the Pharynx Airway (SLIPA) and to compare it to that required for laryngeal mask airway (LMA) insertion in patients receiving a propofol infusion at a standard effect-site concentration. Fifty-eight patients scheduled to undergo general anaesthesia were randomly assigned to either the SLIPA (n = 29) or LMA (n = 29) group. All patients were premedicated with midazolam 0.05 mg x kg(-1) and glycopyrrolate 0.004 mg x kg(-1) intramuscularly. After the administration of lignocaine 1 mg x kg(-1) intravenously, a propofol infusion was started at an effect-site concentration of 3.5 microg x ml(-1) with a remifentanil infusion without a neuromuscular blocking agent. The remifentanil dose was determined by the modified up-and-down method starting in each group at 4 ng x ml(-1). Six minutes after induction, the airway device was inserted. Airway device insertion was classified as 'success' or 'failure' based on patient response. From the isotonic regression analysis and bootstrap distribution, the EC50 of remifentanil for SLIPA and LMA were 0.93 ng x ml(-1) (95% confidence interval [CI] 0.81 to 1.50 ng x ml(-1) and 1.36 ng x ml(-1) (95% CI 1.19 to 2.06 ng x ml(-1)) respectively, and the EC95 for SLIPA and LMA insertions were 1.90 ng x ml(-1) (95% CI 1.39 to 1.95) and 2.43 ng x ml(-1) (95% CI 1.80 to 2.46 ng x ml(-1)) respectively. Using the 83% CIs from the bootstrap distribution, EC50 for SLIPA was significantly less than that of LMA (0.83 to 1.23 vs 1.26 to 2.00, respectively) (P < 0.05). These findings suggest that the insertion of SLIPA needs about a 32% lower depth of anaesthesia than LMA insertion.
Collapse
Affiliation(s)
- S H Kim
- Department of Anesthesiology and Pain Medicine, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Republic of Korea
| | | | | | | | | | | |
Collapse
|
5
|
Galgon RE, Schroeder KM, Han S, Andrei A, Joffe AM. The air-Q(®) intubating laryngeal airway vs the LMA-ProSeal(TM) : a prospective, randomised trial of airway seal pressure. Anaesthesia 2011; 66:1093-100. [PMID: 21880031 DOI: 10.1111/j.1365-2044.2011.06863.x] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
We performed a prospective, open-label, randomised controlled trial comparing the air-Q(®) against the LMA-ProSeal™ in adults undergoing general anaesthesia. One hundred subjects (American Society of Anesthesiologists physical status 1-3) presenting for elective, outpatient surgery were randomly assigned to 52 air-Q(®) and 48 ProSeal devices. The primary study endpoint was airway seal pressure. Oropharyngolaryngeal morbidity was assessed secondarily. Mean (SD) airway seal pressures for the air-Q(®) and ProSeal were 30 (7) cmH (2) O and 30 (6) cmH(2) O, respectively (p = 0.47). Postoperative sore throat was more common with the air-Q(®) (46% vs 38%, p = 0.03) as was pain on swallowing (30% vs 5%, p = 0.01). In conclusion, the air-Q(®) performs well as a primary airway during the maintenance of general anaesthesia with an airway seal pressure similar to that of the ProSeal, but with a higher incidence of postoperative oropharyngolaryngeal complaints.
Collapse
Affiliation(s)
- R E Galgon
- Department of Anesthesiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| | | | | | | | | |
Collapse
|
6
|
A clinical evaluation of four disposable laryngeal masks in adult patients. J Clin Anesth 2008; 20:514-20. [DOI: 10.1016/j.jclinane.2008.05.015] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2007] [Revised: 05/16/2008] [Accepted: 05/16/2008] [Indexed: 12/24/2022]
|
7
|
Kuvaki B, Küçükgüçlü S, Iyilikçi L, Tuncali BE, Cinar O. The Soft Seal disposable laryngeal mask airway in adults: comparison of two insertion techniques without intra-oral manipulation. Anaesthesia 2008; 63:1131-4. [PMID: 18647291 DOI: 10.1111/j.1365-2044.2008.05566.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We investigated whether insertion of the disposable Soft Seal laryngeal mask airway (SSLM) was successful without intra-oral digital manipulation. One hundred patients undergoing anaesthesia using the SSLM were randomly assigned into two groups. Insertion was performed by either a direct or a rotational technique, both without intra-oral digital manipulation. The primary outcome measure was successful insertion at first attempt. Other outcomes included insertion time, fibreoptic assessment of the airway view and airway morbidity. The first attempt success rate was higher (98%) with the direct technique than with the rotational technique (75%; p = 0.002) but insertion time was faster with the latter method (mean [range] 15 [8-50] s) than with the direct method (20 [8-56] s; p = 0.035). Fibreoptic assessment and airway morbidity were similar in both groups. We conclude that the SSLM can be successfully inserted without intra-oral digital manipulation.
Collapse
Affiliation(s)
- B Kuvaki
- Department of Anaesthesiology and Reanimation, Dokuz Eylul University, Izmir, Turkey.
| | | | | | | | | |
Collapse
|
8
|
Hein C, Owen H, Plummer J. Randomized comparison of the SLIPA (Streamlined Liner of the Pharynx Airway) and the SS-LM (Soft Seal Laryngeal Mask) by medical students. Emerg Med Australas 2007; 18:478-83. [PMID: 17083637 DOI: 10.1111/j.1742-6723.2006.00894.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
OBJECTIVE The aim of the study was to compare the Streamlined Liner of the Pharynx Airway (SLIPA; Hudson RCI), a new supraglottic airway device, with the Soft Seal Laryngeal Mask (SS-LM; Portex) when used by novices. METHODS Thirty-six medical students with no previous airway experience, received manikin training in the use of the SLIPA and the SS-LM. Once proficient, the students inserted each device in randomized sequence, in two separate patients in the operating theatre. Only two insertion attempts per patient were allowed. Students were assessed in terms of: device preference; success or failure; success at first attempt and time to ventilation. RESULTS Sixty-seven per cent of the students preferred to use the SLIPA (95% confidence interval 49-81%). The SLIPA was successfully inserted (one or two attempts) in 94% of patients (34/36) and the SS-LM in 89% (32/36) (P = 0.39). First attempt success rates were 83% (30/36) and 67% (24/36) in the SLIPA and SS-LM, respectively (P = 0.10). Median time to ventilation was shorter with the SLIPA (40.6 s) than with the SS-LM (66.9 s) when it was the first device used (P = 0.004), but times were similar when inserting the second device (43.8 s vs 42.9 s) (P = 0.75). CONCLUSIONS In the present study novice users demonstrated high success rates with both devices. The SLIPA group achieved shorter times to ventilation when it was the first device they inserted, which might prove to be of clinical significance, particularly in resuscitation attempts. Although the Laryngeal Mask has gained wide recognition for use by both novice users and as a rescue airway in failed intubation, the data presented here suggest that the SLIPA might also prove useful in these areas.
Collapse
Affiliation(s)
- Cindy Hein
- Flinders University, Bedford Park, SA, Australia.
| | | | | |
Collapse
|
9
|
Gaitini L, Alfery D. Comparison Between the PLA Cobra??? and the Laryngeal Mask Airway Unique???: Choice of Laryngeal Mask Airway Unique Size. Anesth Analg 2007. [DOI: 10.1213/01.ane.0000253685.91890.55] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
10
|
Francksen H, Bein B, Cavus E, Renner J, Scholz J, Steinfath M, Tonner PH, Doerges V. Comparison of LMA Unique, Ambu laryngeal mask and Soft Seal laryngeal mask during routine surgical procedures. Eur J Anaesthesiol 2007; 24:134-40. [PMID: 16895620 DOI: 10.1017/s0265021506001219] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/25/2006] [Indexed: 11/06/2022]
Abstract
BACKGROUND AND OBJECTIVE This study was performed to compare three disposable airway devices, the LMA Unique (LMA-U), the Ambu laryngeal mask (Ambu LM) and the Soft Seal laryngeal mask (Soft Seal LM) for elective general anaesthesia during controlled ventilation in non-paralysed patients. METHODS One hundred and twenty ASA I-III patients scheduled for routine minor obstetric surgery were randomly allocated to the LMA-U (n = 40), Ambu LM (n = 40) or Soft Seal LM (n = 40) groups, respectively. Patients were comparable with respect to weight and airway characteristics. A size 4 LMA was used in all patients and inserted by a single experienced anaesthesiologist. Oxygenation, overall success rate, insertion time, cuff pressure and resulting airway leak pressure were determined as well as a subjective assessment of handling and the incidence of sore throat, dysphagia and hoarseness. RESULTS Time of insertion was shortest with the Ambu LM, while failure rates were comparable with the LMA-U, the Ambu LM and the Soft Seal LM (median 19 s; range 8-57 s; success rate 100% vs. 14; 8-35; 97% vs. 20; 12-46; 95%). Insertion was judged 'excellent' in 75% of patients in the LMA-U group, in 70% of patients in Ambu LM group and in 65% of patients in the Soft Seal LM group. There was no difference between devices with respect to postoperative airway morbidity at 6 h or 24 h following surgery. CONCLUSIONS All three disposable devices were clinically suitable with respect to insertion times, success rates, oxygenation, airway and leak pressures, as well as to subjective handling and postoperative airway morbidity.
Collapse
Affiliation(s)
- H Francksen
- University Hospital Schleswig-Holstein, Department of Anaesthesiology and Intensive Care Medicine, Schwanenweg 21, D-24105 Kiel, Germany
| | | | | | | | | | | | | | | |
Collapse
|