1
|
Warshaw EM, Peterson MY, Atwater AR, DeKoven JG, Pratt MD, Taylor JS, Belsito DV, Silverberg JI, Reeder MJ, DeLeo VA, Houle MC, Dunnick CA, Yu J, Adler B, Mowad C, Botto NC. Patch Testing to Paraphenylenediamine: The North American Contact Dermatitis Group Experience (1994-2018). Dermatitis 2023; 34:536-546. [PMID: 37523239 DOI: 10.1089/derm.2023.0140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/02/2023]
Abstract
Background/Objectives: Paraphenylenediamine (PPD) is an aromatic amine dye that may cause allergic contact dermatitis. This study examines the epidemiology of allergic patch test reactions to PPD. Methods: This retrospective analysis characterizes individuals tested to PPD (1% petrolatum) by the North American Contact Dermatitis Group (1994-2018). Demographics and dermatitis site(s) were compared between PPD-allergic and PPD-negative patients. PPD reactions were analyzed by reaction strength, clinical relevance, occupational relatedness, and source as well as coreactivity with structurally related compounds. Results: Of 54,917 patients tested to PPD, 3095 (5.6%) had an allergic patch test reaction. Compared with PPD-negative patients, PPD-allergic patients had significantly greater odds of age >40 years (odds ratio [OR] 1.55 [95% confidence interval; CI 1.43-1.69]) and female gender (OR 1.52 [95% CI 1.41-1.66]), but lower odds of being White (OR 0.66 [95% CI 0.60-0.71]). The most common primary anatomic sites of dermatitis were face (25.5%), hands (21.9%), and scattered/generalized pattern (15.5%). Over half (55.3%) of PPD reactions were ++ or +++ at the final reading and 60.9% were currently relevant. Common exposure sources included hair dye (73.5%) and clothing/shoes/apparel (3.9%). Occupationally related reactions occurred in 8.3%, most commonly in hairdressers/cosmetologists (72.8%). The most common coreactions were benzocaine (11.3%), N-isopropyl-N'-phenyl-p-phenylenediamine (6.7%), disperse dye mix (6.5%), and black rubber mix (5.1%). Conclusions: The 24-year percentage of allergic reactions to PPD was 5.6%. PPD allergy was associated with female gender and age >40 years. PPD allergic patients were less likely to be White. Allergic reactions were usually clinically relevant and hair dye was the most frequently identified source.
Collapse
Affiliation(s)
- Erin M Warshaw
- From the Department of Dermatology, Park Nicollet/Health Partners Health Services, Minneapolis, Minnesota, USA
- Department of Dermatology, University of Minnesota Medical School, Minneapolis, Minnesota, USA
- Department of Dermatology, Minneapolis Veterans Affairs Medical Center, Minneapolis, Minnesota, USA
| | - Malina Yamashita Peterson
- From the Department of Dermatology, Park Nicollet/Health Partners Health Services, Minneapolis, Minnesota, USA
- University of Minnesota Medical School, Minneapolis, Minnesota, USA
| | - Amber R Atwater
- Department of Dermatology, Duke University Medical Center, Durham, North Carolina, USA
| | - Joel G DeKoven
- Division of Dermatology, Sunnybrook Health Sciences Centre, University of Toronto, Ontario, Canada
| | - Melanie D Pratt
- Division of Dermatology, University of Ottawa, Ontario, Canada
| | - James S Taylor
- Department of Dermatology, Cleveland Clinic, Cleveland, Ohio, USA
| | - Donald V Belsito
- Department of Dermatology, Columbia University Irving Medical School, New York, New York, USA
| | - Jonathan I Silverberg
- Department of Dermatology, The George Washington University School of Medicine and Health Sciences, Washington, District of Columbia, USA
| | - Margo J Reeder
- Department of Dermatology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Vincent A DeLeo
- Department of Dermatology, Keck School of Medicine, University of Southern California, Los Angeles, California, USA
| | - Marie-Claude Houle
- Division of Dermatology, Centre Hospitalier Universitaire de Québec, Laval University, Québec, Canada
| | - Cory A Dunnick
- Department of Dermatology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Jiade Yu
- Department of Dermatology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Brandon Adler
- Department of Dermatology, Keck School of Medicine, University of Southern California, Los Angeles, California, USA
| | - Christen Mowad
- Department of Dermatology, Geisinger Medical Center, Danville, Pennsylvania, USA
| | - Nina C Botto
- Department of Dermatology, University of California San Francisco, San Francisco, California, USA
| |
Collapse
|
2
|
van Amerongen CCA, Kramer D, Pas HH, Schuttelaar MLA. The expression pattern of N-acetyltransferase 1 in healthy human skin. Contact Dermatitis 2021; 85:1-6. [PMID: 33609293 PMCID: PMC8252542 DOI: 10.1111/cod.13821] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 02/05/2021] [Accepted: 02/07/2021] [Indexed: 12/23/2022]
Abstract
Background N‐acetyltransferase 1 (NAT1) is an enzyme expressed among others in keratinocytes in human skin. NAT1 is important in the biotransformation of aromatic amines, an important example being p‐phenylenediamine (PPD), a hair dye molecule. Unoxidized PPD penetrates the skin and is N‐acetylated by NAT1. Objectives To investigate in detail the expression pattern of NAT1 in human skin. Materials and Methods Cryosections obtained from healthy human skin were stained for NAT1 and expression patterns were observed. NAT1 double stainings were performed with antibodies against different cellular organelles to determine expression patterns. Result A speckled, granular expression of NAT1 was seen predominantly in the stratum basale. NAT1 was expressed in a cytoplasmic pattern, perinuclear, and in the nucleus. No co‐localisation was seen with the selected cellular organelles. Local differences in NAT1 expression patterns were observed between donors and between different biopsies obtained from the same donor. Conclusions NAT1 is expressed predominantly in the stratum basale and can be found in the cytoplasm, nucleus, and perinuclear in human skin. Further studies should be performed to investigate expression of NAT1 in a larger sample size.
Collapse
Affiliation(s)
- Cynthia C A van Amerongen
- Department of Dermatology, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands
| | - Duco Kramer
- Department of Dermatology, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands
| | - Hendri H Pas
- Department of Dermatology, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands
| | - Marie L A Schuttelaar
- Department of Dermatology, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands
| |
Collapse
|
3
|
Foti C, Bonamonte D, Romita P, Guarneri F, Patruno C, Angelini G. Common Allergens. CLINICAL CONTACT DERMATITIS 2021:437-497. [DOI: 10.1007/978-3-030-49332-5_22] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
|
4
|
Jędrzejczyk-Patej E, Mazurek M, Kowalski O, Sokal A, Liberska A, Szulik M, Podolecki T, Kalarus Z, Lenarczyk R. Clinical manifestations of device-related infective endocarditis in cardiac resynchronization therapy recipients. Arch Med Sci 2021; 17:638-645. [PMID: 34025833 PMCID: PMC8130459 DOI: 10.5114/aoms.2018.75893] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2018] [Accepted: 04/04/2018] [Indexed: 11/18/2022] Open
Abstract
INTRODUCTION The aim of the study was to analyse microbiological characteristics and clinical manifestations of cardiac device-related infective endocarditis (CDRIE) in cardiac resynchronization therapy (CRT) recipients, and to compare the diagnostic value of modified Duke (MDC) versus modified Duke lead criteria (MDLC; including to MDC local infection and pulmonary infection or embolism as major criteria). MATERIAL AND METHODS The study population comprised 765 consecutive CRT patients from a high-volume, tertiary care centre from 2002 to 2015. All patients were screened for CDRIE. RESULTS During a median follow-up of 1692 days (range: 457-3067) 5.36% of patients (n = 41) developed CDRIE, which was accompanied by CRT pocket infection in 17.1% (n = 7) and recurrent pulmonary infection or pulmonary embolism in 29.3% (n = 12). Fever was present in 95.1% of patients (n = 39), whereas blood cultures were positive in 65.9% (n = 27). Staphylococcus was the most prevalent pathogen in 59.3% (n = 16), Gram-negative bacteria in 25.9% (n = 7). Transoesophageal echocardiography showed intracardiac vegetations in 73.2% of patients (n = 30). Non-different pathogen types with the most common methicillin-sensitive Staphylococcus aureus were observed for early versus late CDRIE (endocarditis ≤ 6 vs. > 6 months from CRT or other device-related procedure). All 3 inflammatory markers (C-reactive protein, white blood cells, procalcitonin) were normal in 4.9% of patients (n = 2). MDC versus MDLC indicated definite CDRIE in 48.8% versus 80.5%, respectively (p = 0.003). CONCLUSIONS Fever is the most common symptom of CRT-related CDRIE, and transoesophageal echocardiography allows vegetations to be visualised in nearly 3/4 of patients with CDRIE. Although the most common pathogens were Staphylococci, Gram-negative bacteria accounted for a quarter of CDRIE. Modified Duke lead criteria proved superior to MDC.
Collapse
Affiliation(s)
- Ewa Jędrzejczyk-Patej
- Department of Cardiology, Congenital Heart Diseases and Electrotherapy, Silesian Centre for Heart Diseases, Zabrze, Poland
| | - Michał Mazurek
- Department of Cardiology, Congenital Heart Diseases and Electrotherapy, Silesian Centre for Heart Diseases, Zabrze, Poland
| | - Oskar Kowalski
- Department of Cardiology, Congenital Heart Diseases and Electrotherapy, Silesian Centre for Heart Diseases, Zabrze, Poland
| | - Adam Sokal
- Department of Cardiology, Congenital Heart Diseases and Electrotherapy, Silesian Centre for Heart Diseases, Zabrze, Poland
| | - Agnieszka Liberska
- Department of Cardiology, Congenital Heart Diseases and Electrotherapy, Silesian Centre for Heart Diseases, Zabrze, Poland
| | - Mariola Szulik
- Department of Cardiology, Congenital Heart Diseases and Electrotherapy, Silesian Centre for Heart Diseases, Zabrze, Poland
| | - Tomasz Podolecki
- Department of Cardiology, Congenital Heart Diseases and Electrotherapy, Silesian Centre for Heart Diseases, Zabrze, Poland
| | - Zbigniew Kalarus
- Department of Cardiology, School of Medicine with the Division of Dentistry, Zabrze, Poland
| | - Radosław Lenarczyk
- Department of Cardiology, Congenital Heart Diseases and Electrotherapy, Silesian Centre for Heart Diseases, Zabrze, Poland
| |
Collapse
|
5
|
Abstract
Allergic contact dermatitis is common, resulting in considerable morbidity. Diagnosis is based on a thorough history, physical examination, and patch testing. Several commercially available panels of patch testing are currently used. Allergens are found in a wide variety of daily products, occupational exposures, and foods. The mainstay of treatment is avoidance of the allergen, and databases like Contact Allergen Management Program and Contact Allergen Replacement Database help patients to select products that do not contain allergens to which they are sensitized. Topical corticosteroids can be used to treat exacerbations, but should be avoided in long-term treatment.
Collapse
Affiliation(s)
- Stacy Nassau
- Department of Internal Medicine, Section of Allergy and Immunology, NYU Winthrop University Hospital, 120 Mineola Boulevard, Suite 410, Mineola, NY 11501, USA.
| | - Luz Fonacier
- Department of Internal Medicine, Section of Allergy and Immunology, NYU Winthrop University Hospital, 120 Mineola Boulevard, Suite 410, Mineola, NY 11501, USA
| |
Collapse
|
6
|
Stingeni L, Bianchi L, Hansel K, Corazza M, Gallo R, Guarneri F, Patruno C, Rigano L, Romita P, Pigatto PD, Calzavara-Pinton P. Italian Guidelines in Patch Testing - adapted from the European Society of Contact Dermatitis (ESCD). GIORN ITAL DERMAT V 2019; 154:227-253. [DOI: 10.23736/s0392-0488.19.06301-6] [Citation(s) in RCA: 72] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
7
|
Abstract
BACKGROUND Contact dermatitis to hair dyes remains a health concern. Regulations in many countries require consumer self-testing for hair dyes, but no standardized procedure exists. OBJECTIVE The aim of this study was to develop a self-test protocol for an allergy alert test (AAT) that can elicit a self-noticeable alert signal in p-phenylenediamine (PPD)-allergic consumers. METHODS Simulating consumer use conditions (open application for 45 minutes after mixing with a developer), PPD-positive hair dye-allergic subjects and PPD-negative control subjects were tested on the forearm and behind the ear with experimental products containing 0.05%, 0.25%, 0.75%, and 2% PPD. Reactions were self-evaluated by subjects and independently assessed by dermatologists. CONCLUSIONS The AAT caused a reaction self-noticeable on the forearm in 90.5% (38/42) and behind the ear in 93% (39/42) of the PPD-positive subjects. This was objectified by a dermatological evaluation. The strength of the AAT response and the number of responding subjects increased with increasing PPD concentrations. Allergy alert test responses were also dependent on the reaction strength of the diagnostic patch test to PPD before the study; in subjects with (+++) patch test reactions, 19 of 19 were positive. All 48 control subjects were negative to the AAT. Therefore, the AAT protocol provides a signal indicative of an allergic reaction in PPD-allergic hair dye consumers.
Collapse
|
8
|
Ferguson FJ, Pongpairoj K, Basketter DA, White IR, McFadden JP. Addressing the conundrums of
p
‐phenylenediamine hair dye allergy by applying Friedmann's principles of contact sensitization. Contact Dermatitis 2018; 80:234-237. [DOI: 10.1111/cod.13171] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Revised: 10/29/2018] [Accepted: 11/02/2018] [Indexed: 11/28/2022]
Affiliation(s)
| | | | | | - Ian R. White
- St John's Institute of Dermatology, Guy's Hospital London UK
| | | |
Collapse
|
9
|
Vogel TA, Prins TM, Dijkstra A, Coenraads PJ, Schuttelaar MLA. The attitude of patients with p-phenylenediamine or 2,5-toluenediamine contact allergy to hair dyeing. Contact Dermatitis 2018; 76:358-361. [PMID: 28497629 DOI: 10.1111/cod.12713] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2016] [Revised: 09/21/2016] [Accepted: 09/25/2016] [Indexed: 11/27/2022]
Affiliation(s)
- Tatiana A Vogel
- Department of Dermatology, University Medical Centre Groningen, University of Groningen, 9700 RB, Groningen, The Netherlands
| | - Thalina M Prins
- Department of Dermatology, University Medical Centre Groningen, University of Groningen, 9700 RB, Groningen, The Netherlands
| | - Arie Dijkstra
- Department of Psychology, University of Groningen, 9712 TS Groningen, The Netherlands
| | - Pieter-Jan Coenraads
- Department of Dermatology, University Medical Centre Groningen, University of Groningen, 9700 RB, Groningen, The Netherlands
| | - Marie L A Schuttelaar
- Department of Dermatology, University Medical Centre Groningen, University of Groningen, 9700 RB, Groningen, The Netherlands
| |
Collapse
|
10
|
Schuttelaar ML, Dittmar D, Burgerhof JGM, Blömeke B, Goebel C. Cross-elicitation responses to 2-methoxymethyl-p-phenylenediamine in p-phenylenediamine-allergic individuals: Results from open use testing and diagnostic patch testing. Contact Dermatitis 2018; 79:288-294. [PMID: 30084179 PMCID: PMC6175459 DOI: 10.1111/cod.13078] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Revised: 06/14/2018] [Accepted: 06/18/2018] [Indexed: 02/03/2023]
Abstract
BACKGROUND Allergic contact dermatitis caused by p-phenylenediamine (PPD) is a health concern for hair dye users. Because of its lower sensitization potency, the PPD derivative 2-methoxymethyl-p-phenylenediamine (ME-PPD) has been developed as an alternative hair dye for primary prevention. However, cross-elicitation responses can occur in PPD-allergic subjects. OBJECTIVES To compare cross-elicitation responses to ME-PPD in open use and diagnostic patch testing of PPD-allergic subjects with hair dye-related allergic contact dermatitis. METHODS Reactions to ME-PPD were investigated in 25 PPD-allergic subjects by performing (1) 45-minute open use testing with a hair dye containing 2.0% of either ME-PPD or PPD, and (2) patch testing with increasing ME-PPD concentrations (0.1%-2.0% pet.). RESULTS Of the 25 PPD-allergic subjects, 21 (84%) reacted to open use testing with a hair dye containing 2.0% PPD, and testing with 2.0% ME-PPD led to cross-elicitation in 12 (48%). When patch tested with increasing ME-PPD concentrations, 13 (52%) cross-reacted at 0.1% (lowest dose) and 21 (84%) at 2.0% (highest dose), indicating decreased reactivity as compared with published PPD dose-response data. CONCLUSION In line with the decreased cross-reactivity of ME-PPD in hair dye open use testing, PPD-allergic subjects show an attenuated cross-elicitation dose response to ME-PPD in patch testing.
Collapse
Affiliation(s)
- Marie L Schuttelaar
- Department of Dermatology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Daan Dittmar
- Department of Dermatology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Johannes G M Burgerhof
- Department of Epidemiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Brunhilde Blömeke
- Department of Environmental Toxicology, Trier University, Trier, Germany
| | | |
Collapse
|
11
|
Han JH, Lee HJ, Bang CH, Lee JH, Park YM, Lee JY. P-Phenylenediamine Hair Dye Allergy and Its Clinical Characteristics. Ann Dermatol 2018; 30:316-321. [PMID: 29853746 PMCID: PMC5929949 DOI: 10.5021/ad.2018.30.3.316] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Revised: 11/28/2017] [Accepted: 12/14/2017] [Indexed: 11/08/2022] Open
Abstract
Background P-phenylenediamine (PPD) has been identified as the most frequent contact sensitizer of hair dye and the clinical characteristics of hair dye contact allergy (HDCA) are diverse. Objective The purpose of this study was to identify the clinical characteristics of HDCA and to assess the relationships between HDCA, exposure time to PPD and PPD positivity. Methods We analyzed 105 patients with patch test-confirmed hair dye allergy who presented between July 2009 and March 2015. Clinical symptoms, signs, associated skin diseases, involved ACD area, and patterns of hair dye use were obtained by reviewing medical records and by interview. Results HDCA was more common in women and in individuals aged more than 50 years. Pruritus was the most common symptom; erythematous macules and patches were the most frequently observed clinical signs. The most common site of HDCA was the face and non-specific eczema and urticaria were frequently observed with HDCA. Exposure time to hair dye, represented as frequency and duration, showed a positive correlation with the area affected by hair dye allergy (p<0.001). Hair dye allergy was identified in most patients (80%) before diagnosis by patch test. However, only 28.6% of all patients stopped using hair dye, even after the diagnosis was confirmed. Conclusion The extent of hair dye allergy involvement was related to exposure time to hair dye. For effective treatment of HDCA, it is important to properly educate patients with HDCA about the clinical manifestations of HDCA and to keep away from allergens.
Collapse
Affiliation(s)
- Ju Hee Han
- Department of Dermatology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Hyun Ji Lee
- Department of Dermatology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Chul Hwan Bang
- Department of Dermatology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Ji Hyun Lee
- Department of Dermatology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Young Min Park
- Department of Dermatology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Jun Young Lee
- Department of Dermatology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| |
Collapse
|
12
|
Abstract
The International Contact Dermatitis Research Group proposes a classification for the clinical presentation of contact allergy. The classification is based primarily on the mode of clinical presentation. The categories are direct exposure/contact dermatitis, mimicking or exacerbation of preexisting eczema, multifactorial dermatitis including allergic contact dermatitis, by proxy, mimicking angioedema, airborne contact dermatitis, photo-induced contact dermatitis, systemic contact dermatitis, noneczematous contact dermatitis, contact urticaria, protein contact dermatitis, respiratory/mucosal symptoms, oral contact dermatitis, erythroderma/exfoliative dermatitis, minor forms of presentation, and extracutaneous manifestations.
Collapse
|
13
|
Schubert S, Lessmann H, Schnuch A, Uter W, Geier J. Factors associated with p-phenylenediamine sensitization: data from the Information Network of Departments of Dermatology, 2008-2013. Contact Dermatitis 2018; 78:199-207. [PMID: 29322532 DOI: 10.1111/cod.12920] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Revised: 09/22/2017] [Accepted: 10/04/2017] [Indexed: 11/29/2022]
Abstract
BACKGROUND Risk factors for p-phenylenediamine (PPD) sensitization include the use of hair dyes, the application of temporary black henna tattoos, working as a hairdresser, and, possibly, exposure to hair dye pretests. OBJECTIVES To quantify the impact of these (putative) risk factors on PPD sensitization. METHODS Six items related to PPD exposure were added to the routine Information Network of Departments of Dermatology questionnaire from 2008 to 2013. A retrospective analysis of data from 4314 patients tested with PPD 1% pet. was conducted. RESULTS Of the PPD-positive patients (n = 271), 80% had their hair dyed, and, of these, 57% subsequently developed scalp dermatitis, whereas only 11% had had a henna tattoo. The self-administrated pretest with hair dye was performed by only a few patients, precluding a more detailed analysis. Hair dyeing [odds ratio (OR) 6.0; 95% confidence interval (CI): 3.9-9.4], henna tattoos (OR 2.4; 95%CI: 1.5-3.7) and being a hairdresser (OR 2.1; 95%CI: 1.3-3.2) increased the risk of PPD sensitization. Neither dyeing of own hair nor application of a temporary henna tattoo seemed to affect PPD sensitization in hairdressers. p-Aminoaryl compounds more often gave positive reactions in patients with henna tattoo. CONCLUSIONS Hair dyeing is the major risk factor for PPD sensitization in this clinical setting, and application of a temporary black henna tattoo may also lead to (strong) PPD sensitization.
Collapse
Affiliation(s)
- Steffen Schubert
- Information Network of Departments of Dermatology (IVDK), University of Göttingen, 37075, Göttingen, Germany
| | - Holger Lessmann
- Information Network of Departments of Dermatology (IVDK), University of Göttingen, 37075, Göttingen, Germany
| | - Axel Schnuch
- Information Network of Departments of Dermatology (IVDK), University of Göttingen, 37075, Göttingen, Germany
| | - Wolfgang Uter
- Department of Medical Informatics, Biometry and Epidemiology, Friedrich-Alexander University Erlangen-Nürnberg, 91054, Erlangen, Germany
| | - Johannes Geier
- Information Network of Departments of Dermatology (IVDK), University of Göttingen, 37075, Göttingen, Germany
| | | |
Collapse
|
14
|
Diagnosing Allergic Contact Dermatitis Through Elimination, Perception, Detection and Deduction. Am J Clin Dermatol 2017; 18:651-661. [PMID: 28508257 DOI: 10.1007/s40257-017-0287-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Several authors have commented upon the skills of detection required in making a diagnosis of allergic contact dermatitis. Here, we emphasise the search for clues in a systematic manner. We describe four stages as part of a systematic method for diagnosing allergic contact dermatitis. Firstly, elimination (or inclusion) of non-allergic diagnoses. Secondly, perception: the pre-patch test diagnosis and the 'three scenarios' principle. Thirdly, detection: optimising the sensitivity of the patch test process. Fourthly, deduction: diagnosing allergic contact dermatitis by associating the dermatitis with the allergen exposure. We further compare and contrast the pre-patch test history and examination with the markedly different one ('microhistory' and 'microexamination') used after patch testing. The importance of knowledge of contact dermatitis literature is emphasised with a review of recent publications. Finally, we also highlight the use of contact allergy profiling as an investigative tool in the diagnosis of allergic contact dermatitis.
Collapse
|
15
|
|
16
|
Basketter DA, White IR, Kullavanijaya P, Tresukosol P, Wichaidit M, McFadden JP. Influence of vitamin C on the elicitation of allergic contact dermatitis to p-phenylenediamine. Contact Dermatitis 2016; 74:368-72. [PMID: 27027508 DOI: 10.1111/cod.12576] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2016] [Revised: 02/18/2016] [Accepted: 02/18/2016] [Indexed: 11/29/2022]
Abstract
BACKGROUND Hair dyes represent one of the most important causes of allergic contact dermatitis resulting from the use of cosmetic products. The principal causative chemistry is associated with oxidation products of p-phenylenediamine (PPD) and closely related substances. OBJECTIVES To examine whether prior application of the antioxidant vitamin C to the skin was able to reduce the cutaneous allergic response to PPD. METHODS Twenty eight volunteers with a proven history of contact allergy to PPD were recruited. Each was tested with a range of PPD doses and PPD-containing hair dye on untreated skin and skin pretreated for 10 min with a vitamin C formulation. RESULTS Pretreatment of skin sites with vitamin C led to a reduction in the intensity, or even ablation, of the cutaneous allergic reaction to PPD in ∼75% of cases as compared with untreated skin. CONCLUSIONS The results suggest that treatment of the skin adjacent to the hair-bearing area with antioxidant could form part of a strategy to reduce the burden of cosmetic allergic contact dermatitis caused by hair dyeing.
Collapse
|
17
|
Kock M, Coenraads PJ, Blömeke B, Goebel C. Continuous usage of a hair dye product containing 2-methoxymethyl-para-phenylenediamine by hair-dye-allergic individuals. Br J Dermatol 2016; 174:1042-50. [PMID: 26749506 DOI: 10.1111/bjd.14390] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/30/2015] [Indexed: 11/27/2022]
Abstract
BACKGROUND Despite a positive patch test reaction to para-phenylenediamine (PPD) and/or toluene-2,5-diamine (PTD), many people attempt to continue dyeing their hair with products containing PPD or its derivatives. OBJECTIVES Investigation of elicitation reactions among PPD/PTD-allergic individuals to hair dye products containing the less sensitizing PPD derivative 2-methoxymethyl (ME)-PPD. METHODS Elicitation reactions were studied in 43 PPD/PTD-allergic individuals by a 45-min pretest with an ME-PPD-containing hair dye on their forearm. Upon a negative result this was followed by exposure to subsequent hair colour treatment(s). RESULTS Overall, 38 of 43 PPD/PTD-allergic individuals did not develop an elicitation reaction during the pretest with ME-PPD-containing hair dye products, and were eligible for subsequent hair colour treatments. Of these 38 PPD/PTD-allergic individuals, 29 tolerated subsequent hair dyeing with ME-PPD-containing hair dye products, while seven showed mild and two showed moderate/marked allergic reactions upon the first hair colour treatment. CONCLUSIONS Hair dye products with the less sensitizing ME-PPD were tolerated by 29 of 43 (67%) PPD/PTD-allergic individuals throughout continued hair dyeing with an average of nine treatments per year. Five individuals reacted upon pretesting, while only mild-to-moderate/marked skin reactions occurred upon hair dyeing in nine individuals who were not identified by the pretest. To our knowledge this is the first study among PPD/PTD-allergic individuals indicating that a negative 45-min pretest with a hair dye product helps to avoid severe allergic reactions.
Collapse
Affiliation(s)
- M Kock
- Global Safety Surveillance & Analysis and Central Product Safety, The Procter & Gamble Co., Schwalbach am Taunus, Germany
| | - P-J Coenraads
- Dermatology Department, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - B Blömeke
- Department of Environmental Toxicology, University Trier, Trier, Germany
| | - C Goebel
- Global Safety Surveillance & Analysis and Central Product Safety, The Procter & Gamble Co., Schwalbach am Taunus, Germany
| |
Collapse
|
18
|
Coenraads PJ, Vogel TA, Blömeke B, Goebel C, Roggeband R, Schuttelaar MLA. The role of the antioxidant ascorbic acid in the elicitation of contact allergic reactions to p-phenylenediamine. Contact Dermatitis 2016; 74:267-72. [PMID: 26875881 DOI: 10.1111/cod.12535] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2015] [Revised: 10/07/2015] [Accepted: 12/08/2015] [Indexed: 02/06/2023]
Abstract
BACKGROUND An allergic contact reaction is accompanied by high oxidative stress in the skin. Pretreatment of the skin with antioxidative substances could reduce the elicitation reaction. OBJECTIVES To investigate, in a proof-of-principle study, whether pretreatment of the skin with the antioxidant ascorbic acid reduces the elicitation reaction to a p-phenylenediamine (PPD)-containing hair dye in sensitized subjects. METHODS Twelve subjects with contact allergy to PPD, a documented skin reaction to a hair dye simulation exposure model and a history of hair dye-related skin complaints were included in this study. Skin areas on the forearms were, in a left versus right design, exposed to an emulsion with ascorbic acid and an emulsion without ascorbic acid, and then to a 2% PPD-containing hair dye testing formulation. In addition, control areas were exposed to the emulsions and to the PPD-containing hair dye formulation without pretreatment. Skin reactions were graded on day (D)2 and D3. RESULTS Pretreatment with ascorbic acid emulsion resulted in a reduction in the elicitation reaction in 7 of 12 subjects at D3 (p = 0.046). No statistically significant difference was observed at D2. CONCLUSIONS Pretreatment of the skin with the antioxidant ascorbic acid had an attenuating effect on the elicitation reaction to PPD in sensitized individuals.
Collapse
Affiliation(s)
- Pieter-Jan Coenraads
- Department of Dermatology, University Medical Center Groningen, University of Groningen, 9700 RB, Groningen, The Netherlands
| | - Tatiana A Vogel
- Department of Dermatology, University Medical Center Groningen, University of Groningen, 9700 RB, Groningen, The Netherlands
| | - Brunhilde Blömeke
- Department of Environmental Toxicology, Trier University, 54296, Trier, Germany
| | - Carsten Goebel
- The Procter & Gamble Company, Central Product Safety, 65823 Schwalbach am Taunus, Germany.,The Procter & Gamble Company, Central Product Safety, 1853, Strombeek-Bever, Belgium
| | - Robert Roggeband
- The Procter & Gamble Company, Central Product Safety, 65823 Schwalbach am Taunus, Germany.,The Procter & Gamble Company, Central Product Safety, 1853, Strombeek-Bever, Belgium
| | - Marie-Louise A Schuttelaar
- Department of Dermatology, University Medical Center Groningen, University of Groningen, 9700 RB, Groningen, The Netherlands
| |
Collapse
|
19
|
Fonacier L, Bernstein DI, Pacheco K, Holness DL, Blessing-Moore J, Khan D, Lang D, Nicklas R, Oppenheimer J, Portnoy J, Randolph C, Schuller D, Spector S, Tilles S, Wallace D. Contact dermatitis: a practice parameter-update 2015. THE JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE 2016; 3:S1-39. [PMID: 25965350 DOI: 10.1016/j.jaip.2015.02.009] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 02/25/2015] [Accepted: 02/26/2015] [Indexed: 01/08/2023]
Abstract
This parameter was developed by the Joint Task Force on Practice Parameters, which represents the American Academy of Allergy, Asthma & Immunology (AAAAI); the American College of Allergy, Asthma & Immunology (ACAAI); and the Joint Council of Allergy, Asthma & Immunology. The AAAAI and the ACAAI have jointly accepted responsibility for establishing "Contact Dermatitis: A Practice Parameter-Update 2015." This is a complete and comprehensive document at the current time. The medical environment is changing and not all recommendations will be appropriate or applicable to all patients. Because this document incorporated the efforts of many participants, no single individual, including members serving on the Joint Task Force, are authorized to provide an official AAAAI or ACAAI interpretation of these practice parameters. Any request for information or interpretation of this practice parameter by the AAAAI or ACAAI should be directed to the Executive Offices of the AAAAI, the ACAAI, and the Joint Council of Allergy, Asthma & Immunology. These parameters are not designed for use by the pharmaceutical industry in drug development or promotion. Previously published practice parameters of the Joint Task Force on Practice Parameters for Allergy & Immunology are available at http://www.JCAAI.org or http://www.allergyparameters.org.
Collapse
|
20
|
Johansen JD, Aalto-Korte K, Agner T, Andersen KE, Bircher A, Bruze M, Cannavó A, Giménez-Arnau A, Gonçalo M, Goossens A, John SM, Lidén C, Lindberg M, Mahler V, Matura M, Rustemeyer T, Serup J, Spiewak R, Thyssen JP, Vigan M, White IR, Wilkinson M, Uter W. European Society of Contact Dermatitis guideline for diagnostic patch testing - recommendations on best practice. Contact Dermatitis 2015; 73:195-221. [PMID: 26179009 DOI: 10.1111/cod.12432] [Citation(s) in RCA: 1005] [Impact Index Per Article: 100.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Revised: 04/29/2015] [Accepted: 05/06/2015] [Indexed: 11/27/2022]
Abstract
The present guideline summarizes all aspects of patch testing for the diagnosis of contact allergy in patients suspected of suffering, or having been suffering, from allergic contact dermatitis or other delayed-type hypersensitivity skin and mucosal conditions. Sections with brief descriptions and discussions of different pertinent topics are followed by a highlighted short practical recommendation. Topics comprise, after an introduction with important definitions, materials, technique, modifications of epicutaneous testing, individual factors influencing the patch test outcome or necessitating special considerations, children, patients with occupational contact dermatitis and drug eruptions as special groups, patch testing of materials brought in by the patient, adverse effects of patch testing, and the final evaluation and patient counselling based on this judgement. Finally, short reference is made to aspects of (continuing) medical education and to electronic collection of data for epidemiological surveillance.
Collapse
Affiliation(s)
- Jeanne D Johansen
- Department of Dermato-Allergology, National Allergy Research Centre, Gentofte Hospital, University of Copenhagen, 2900 Hellerup, Denmark
| | - Kristiina Aalto-Korte
- Occupational Medicine, Finnish Institute of Occupational Health, 00250 Helsinki, Finland
| | - Tove Agner
- Department of Dermatology, Bispebjerg Hospital, University of Copenhagen, 2400 Copenhagen, Denmark
| | - Klaus E Andersen
- Department of Dermatology and Allergy Centre, Odense University Hospital, University of Southern Denmark, 5000 Odense, Denmark
| | - Andreas Bircher
- Allergy Unit, Department of Dermatology, University Hospital and University of Basel, 4031 Basel, Switzerland
| | - Magnus Bruze
- Department of Occupational and Environmental Dermatology, Skåne University Hospital, Lund University, SE-20502 Malmö, Sweden
| | - Alicia Cannavó
- Hospital Municipal de Vicente López 'Profesor Bernard Houssay', Buenos Aires, Argentina
| | - Ana Giménez-Arnau
- Department of Dermatology, Hospital del Mar, Universitat Autónoma de Barcelona, 08003 Barcelona, Spain
| | - Margarida Gonçalo
- Department of Dermatology, University Hospital and Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal
| | - An Goossens
- Contact Allergy Unit, Department of Dermatology, University Hospital K. U. Leuven, B-3000 Leuven, Belgium
| | - Swen M John
- Department of Dermatology, Environmental Medicine, Health Theory, University of Osnabrueck, D-49069 Osnabrueck, Germany
| | - Carola Lidén
- Institute of Environmental Medicine, Karolinska Institutet, SE-17177 Stockholm, Sweden
| | - Magnus Lindberg
- Department of Dermatology, University Hospital Örebro, SE-70185 Örebro, Sweden
| | - Vera Mahler
- Allergy Unit, Department of Dermatology, University Hospital Erlangen, 91054 Erlangen, Germany
| | - Mihály Matura
- Unit of Occupational and Environmental Dermatology, Centre for Occupational and Environmental Medicine, SLSO, SE-11365 Stockholm, Sweden
| | - Thomas Rustemeyer
- Department of Dermatology, VU University Medical Centre, 1081 HV Amsterdam, The Netherlands
| | - Jørgen Serup
- Department of Dermatology, Bispebjerg Hospital, University of Copenhagen, 2400 Copenhagen, Denmark
| | - Radoslaw Spiewak
- Department of Experimental Dermatology and Cosmetology, Jagiellonian University Medical College, 30-688 Krakow, Poland
| | - Jacob P Thyssen
- Department of Dermato-Allergology, National Allergy Research Centre, Gentofte Hospital, University of Copenhagen, 2900 Hellerup, Denmark
| | - Martine Vigan
- Department of Dermatology, CHRU Besançon, 25030 Besançon Cedex, France
| | - Ian R White
- Department of Cutaneous Allergy, St John's Institute of Dermatology, St Thomas' Hospital, London, SE1 7EH, UK
| | | | - Wolfgang Uter
- Department of Medical Informatics, Biometry and Epidemiology, University of Erlangen/Nürnberg, 91054 Erlangen, Germany
| |
Collapse
|
21
|
Gupta M, Mahajan VK, Mehta KS, Chauhan PS. Hair dye dermatitis and p-phenylenediamine contact sensitivity: A preliminary report. Indian Dermatol Online J 2015; 6:241-6. [PMID: 26225326 PMCID: PMC4513401 DOI: 10.4103/2229-5178.160253] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND The contact allergic reactions from p-phenylenediamine (PPD) in hair dyes vary from mild contact dermatitis to severe life- threatening events (angioedema, bronchospasm, asthma, renal impairment). OBJECTIVES To study the clinical patterns and PPD contact sensitivity in patients with hair-dye dermatitis. MATERIALS AND METHODS Eighty (M:F 47:33) consecutive patients aged between 18 and 74 years suspected to have contact allergy from hair dye were studied by patch testing with Indian Standard Series including p-phenylenediamine (PPD, 1.0% pet). RESULTS 54 Fifty-four (M:F 21:33) patients showed positive patch tests from PPD. Eight of these patients also showed positive patch test reaction from fragrance mix, thiuram mix, paraben mix, or colophony. Fifty-seven (71%) patients affected were aged older than 40 years. The duration of dermatitis varied from < 1 month to > 1 year with exacerbation following hair coloring. Forty-nine patients had dermatitis of scalp and/or scalp margins and 23 patients had face and neck dermatitis. Periorbital dermatitis, chronic actinic dermatitis, and erythema multiforme-like lesions were seen in 4, 2, and 1 patients, respectively. CONCLUSIONS Hair dyes and PPD constitute a significant cause of contact dermatitis. There is an urgent need for creating consumer awareness regarding hair-dyes contact sensitivity and the significance of performing sensitivity testing prior to actual use.
Collapse
Affiliation(s)
- Mrinal Gupta
- Department of Dermatology, Venereology and Leprosy, Dr. Rajendra Prasad, Government Medical College, Tanda, Himachal Pradesh, India
| | - Vikram K. Mahajan
- Department of Dermatology, Venereology and Leprosy, Dr. Rajendra Prasad, Government Medical College, Tanda, Himachal Pradesh, India
| | - Karaninder S. Mehta
- Department of Dermatology, Venereology and Leprosy, Dr. Rajendra Prasad, Government Medical College, Tanda, Himachal Pradesh, India
| | - Pushpinder S. Chauhan
- Department of Dermatology, Venereology and Leprosy, Dr. Rajendra Prasad, Government Medical College, Tanda, Himachal Pradesh, India
| |
Collapse
|
22
|
Vogel TA, Coenraads PJ, Bijkersma LM, Vermeulen KM, Schuttelaar MLA. p-Phenylenediamine exposure in real life - a case-control study on sensitization rate, mode and elicitation reactions in the northern Netherlands. Contact Dermatitis 2015; 72:355-61. [DOI: 10.1111/cod.12354] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2014] [Revised: 11/21/2014] [Accepted: 12/23/2014] [Indexed: 11/28/2022]
Affiliation(s)
- Tatiana A. Vogel
- Department of Dermatology; University Medical Center Groningen; 9700 RB Groningen The Netherlands
| | - Pieter-Jan Coenraads
- Department of Dermatology; University Medical Center Groningen; 9700 RB Groningen The Netherlands
| | - Laura M. Bijkersma
- Department of Dermatology; University Medical Center Groningen; 9700 RB Groningen The Netherlands
| | - Karin M. Vermeulen
- Department of Epidemiology; University Medical Center Groningen; 9700 RB Groningen The Netherlands
| | | | | |
Collapse
|
23
|
Lee JY, Kim CW, Kim SS. Analysis of the Results from the Patch Test to Para-Phenylenediamine in the TRUE Test in Patients with a Hair Dye Contact Allergy. Ann Dermatol 2015; 27:171-7. [PMID: 25834356 PMCID: PMC4377406 DOI: 10.5021/ad.2015.27.2.171] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2013] [Revised: 06/27/2014] [Accepted: 07/21/2014] [Indexed: 11/12/2022] Open
Abstract
Background Para-phenylenediamine (PPD) is the primary patch test screening agent for hair dye contact allergy (HDCA). However, no recent studies have been published that describe the results of reactions to patch tests using PPD and hair dyes in Korea. Objective To analyze the results of the patch tests to PPD using the thin-layer rapid use epicutaneous (TRUE) Test system in patients with HDCA and to investigate patients' awareness that hair dyes contains allergens, which cause the development of HDCA. Methods Eighty-four patients with suspected HDCA (32 men and 52 women) underwent patch testing using the TRUE Test system and their own hair dyes. The patients' demographic data, behavior associated with hair dyeing, and clinical manifestations of HDCA were examined retrospectively. Results Positive patch-test reactions to hair dyes occurred in 53.6% of patients who used hair dyes, and they were diagnosed with HDCA. Although there was a significant correlation between HDCA and PPD sensitization (p=0.001), only 40% of the patients with HDCA showed positive reactions to PPD. Of the 45 patients diagnosed with HDCA, only 7 (15.6%) were aware that their hair dyes contained allergens that caused HDCA. Conclusion This study's findings show that PPD is an effective HDCA marker. However, we propose that investigations on hair dye components other than PPD should be conducted to develop and validate additional predictive HDCA markers.
Collapse
Affiliation(s)
- Jin Yong Lee
- Department of Dermatology, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea
| | - Chul Woo Kim
- Department of Dermatology, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea
| | - Sang Seok Kim
- Department of Dermatology, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea
| |
Collapse
|
24
|
Pot L, Coenraads P, Goebel C, Blömeke B. Assessment of the elicitation response in subjects weakly sensitized top-phenylenediamine. Br J Dermatol 2014; 172:138-44. [DOI: 10.1111/bjd.13142] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/20/2014] [Indexed: 11/30/2022]
Affiliation(s)
- L.M. Pot
- Department of Dermatology; University Medical Center Groningen; University of Groningen; Groningen the Netherlands
| | - P.J. Coenraads
- Department of Dermatology; University Medical Center Groningen; University of Groningen; Groningen the Netherlands
| | - C. Goebel
- The Procter and Gamble Company; Central Product Safety; Darmstadt Germany
| | - B. Blömeke
- Department of Environmental Toxicology; University Trier; Trier Germany
| |
Collapse
|
25
|
Jenkins D, Chow ET. Allergic contact dermatitis to para-phenylenediamine. Australas J Dermatol 2014; 56:40-3. [PMID: 25302475 DOI: 10.1111/ajd.12189] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2013] [Accepted: 03/17/2014] [Indexed: 11/30/2022]
Abstract
Exposure to hair dye is the most frequent route of sensitisation to para-phenylenediamine (PPD), a common contact allergen. International studies have examined the profile of PPD, but Australian-sourced information is lacking. Patients are often dissatisfied with advice to stop dyeing their hair. This study examines patients' characteristics, patch test results and outcomes of PPD allergy from a single Australian centre, through a retrospective analysis of patch test data from 2006 to 2013 at the Liverpool Hospital Dermatology Department. It reviews the science of hair dye allergy, examines alternative hair dyes and investigates strategies for hair dyeing. Of 584 patients, 11 were allergic to PPD. Our PPD allergy prevalence rate of 2% is at the lower end of international reported rates. About half these patients also react to para-toluenediamine (PTD). Affected patients experience a significant lifestyle disturbance. In all, 78% tried alternative hair dyes after the patch test diagnosis and more than half continued to dye their hair. Alternative non-PPD hair dyes are available but the marketplace can be confusing. Although some patients are able to tolerate alternative hair dyes, caution is needed as the risk of developing an allergy to other hair dye ingredients, especially PTD, is high.
Collapse
Affiliation(s)
- David Jenkins
- Department of Dermatology, Liverpool Hospital, Sydney, New South Wales, Australia
| | | |
Collapse
|
26
|
Thomas BR, White IR, McFadden JP, Banerjee P. Positive relationship-intensity of response to p-phenylenediamine on patch testing and cross-reactions with related allergens. Contact Dermatitis 2014; 71:98-101. [PMID: 24850439 DOI: 10.1111/cod.12255] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2013] [Revised: 04/08/2014] [Accepted: 04/22/2014] [Indexed: 11/28/2022]
Abstract
BACKGROUND Hair dye exposure is the most common cause of sensitization to p-phenylenediamine (PPD). Cross-reactions with structurally related allergens occur. OBJECTIVES It is suggested that a stronger patch test reaction (3+ rather than 1+) to PPD (usually tested as 1% petrolatum) is associated with an increased propensity for cross-reactions. In this article we will demonstrate this association. METHODS Of 230 patients with allergic reactions to PPD on patch testing identified during 2007-2012 from clinical records, notes for 221 were available for review. Data were collected regarding age, sex, and grade of reaction [International Contact Dermatitis Research Group (ICDRG) criteria] to PPD. Cross-reactions with the following allergens, found in our baseline series, were recorded: Disperse Yellow 3, N-isopropyl-N'-phenyl-p-phenylenediamine (IPPD), and caine mix. Having excluded 23 doubtful reactions, the reactions from 198 patients were further considered. RESULTS Of the patients, 75.3% (n = 149) were female, and the mean age was 48.6 years (12-82 years). Of the patients allergic to PPD, 16.6% (n = 33) showed cross-reactions with one or more related allergens. Cross-reactions were seen in 16% with a grade of 1+, 14.5% with a grade of 2+, 28.6% with a grade of 3+ when PPD was tested 1% pet., and 50.0% when PPD was tested at 0.1-0.001%, arbitrarily considered to be 4+ (p = 0.02; Cramér's V = 0.23). CONCLUSION An increasing likelihood of reactions to Disperse Yellow 3, IPPD or caine mix was seen with increasing strength of patch test reaction to PPD. The clinical relevance of these cross-reactions is unclear.
Collapse
Affiliation(s)
- Bjorn R Thomas
- Department of Cutaneous Allergy, St John's Institute of Dermatology, London, SE1 7EH, UK
| | | | | | | |
Collapse
|
27
|
Schoeffler A, Waton J, Latarche C, Poreaux C, Cuny JF, Schmutz JL, Barbaud A. Évolution de la batterie standard européenne de 1981 à 2011 dans un centre de dermato-allergologie français. Ann Dermatol Venereol 2013; 140:499-509. [DOI: 10.1016/j.annder.2013.02.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2012] [Revised: 01/21/2013] [Accepted: 02/14/2013] [Indexed: 10/27/2022]
|
28
|
Goebel C, Diepgen TL, Krasteva M, Schlatter H, Nicolas JF, Blömeke B, Coenraads PJ, Schnuch A, Taylor JS, Pungier J, Fautz R, Fuchs A, Schuh W, Gerberick GF, Kimber I. Quantitative risk assessment for skin sensitisation: Consideration of a simplified approach for hair dye ingredients. Regul Toxicol Pharmacol 2012; 64:459-65. [DOI: 10.1016/j.yrtph.2012.10.004] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2012] [Revised: 09/18/2012] [Accepted: 10/07/2012] [Indexed: 11/15/2022]
|
29
|
Basketter DA, McFadden JP, Kimber I. Assessing the severity of allergic reactions: a regulatory dilemma. Contact Dermatitis 2012; 67:3-8. [DOI: 10.1111/j.1600-0536.2012.02102.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
30
|
Thyssen JP, Søsted H, Uter W, Schnuch A, Giménez-Arnau AM, Vigan M, Rustemeyer T, Granum B, McFadden J, White JM, White IR, Goossens A, Menné T, Lidén C, Johansen JD. Self-testing for contact sensitization to hair dyes - scientific considerations and clinical concerns of an industry-led screening programme. Contact Dermatitis 2012; 66:300-11. [DOI: 10.1111/j.1600-0536.2012.02078.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
31
|
|
32
|
Peiser M, Tralau T, Heidler J, Api AM, Arts JHE, Basketter DA, English J, Diepgen TL, Fuhlbrigge RC, Gaspari AA, Johansen JD, Karlberg AT, Kimber I, Lepoittevin JP, Liebsch M, Maibach HI, Martin SF, Merk HF, Platzek T, Rustemeyer T, Schnuch A, Vandebriel RJ, White IR, Luch A. Allergic contact dermatitis: epidemiology, molecular mechanisms, in vitro methods and regulatory aspects. Current knowledge assembled at an international workshop at BfR, Germany. Cell Mol Life Sci 2011; 69:763-81. [PMID: 21997384 PMCID: PMC3276771 DOI: 10.1007/s00018-011-0846-8] [Citation(s) in RCA: 232] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2011] [Revised: 08/29/2011] [Accepted: 09/20/2011] [Indexed: 12/13/2022]
Abstract
Contact allergies are complex diseases, and one of the important challenges for public health and immunology. The German ‘Federal Institute for Risk Assessment’ hosted an ‘International Workshop on Contact Dermatitis’. The scope of the workshop was to discuss new discoveries and developments in the field of contact dermatitis. This included the epidemiology and molecular biology of contact allergy, as well as the development of new in vitro methods. Furthermore, it considered regulatory aspects aiming to reduce exposure to contact sensitisers. An estimated 15–20% of the general population suffers from contact allergy. Workplace exposure, age, sex, use of consumer products and genetic predispositions were identified as the most important risk factors. Research highlights included: advances in understanding of immune responses to contact sensitisers, the importance of autoxidation or enzyme-mediated oxidation for the activation of chemicals, the mechanisms through which hapten-protein conjugates are formed and the development of novel in vitro strategies for the identification of skin-sensitising chemicals. Dendritic cell cultures and structure-activity relationships are being developed to identify potential contact allergens. However, the local lymph node assay (LLNA) presently remains the validated method of choice for hazard identification and characterisation. At the workshop the use of the LLNA for regulatory purposes and for quantitative risk assessment was also discussed.
Collapse
Affiliation(s)
- M. Peiser
- Department of Product Safety, German Federal Institute for Risk Assessment (BfR), Thielallee 88-92, 14195 Berlin, Germany
| | - T. Tralau
- Department of Product Safety, German Federal Institute for Risk Assessment (BfR), Thielallee 88-92, 14195 Berlin, Germany
| | - J. Heidler
- Department of Product Safety, German Federal Institute for Risk Assessment (BfR), Thielallee 88-92, 14195 Berlin, Germany
| | - A. M. Api
- Research Institute for Fragrance Materials, Hackensack, NJ USA
| | | | | | - J. English
- Nottingham University Hospitals, Nottingham, UK
| | - T. L. Diepgen
- Department of Social Medicine, Occupational and Environmental Dermatology, University of Heidelberg, Heidelberg, Germany
| | | | - A. A. Gaspari
- School of Medicine, University of Maryland, Baltimore, MD USA
| | - J. D. Johansen
- Department of Derma-allergology, Gentofte Hospital, University of Copenhagen, Copenhagen, Denmark
| | - A. T. Karlberg
- Department of Chemistry, Dermatochemistry and Skin Allergy, University of Gothenburg, Gothenburg, Sweden
| | - I. Kimber
- Faculty of Life Sciences, University of Manchester, Manchester, UK
| | | | - M. Liebsch
- Department of Experimental Toxicology and ZEBET, Center for Alternatives to Animal Testing, German Federal Institute for Risk Assessment (BfR), Berlin, Germany
| | - H. I. Maibach
- Department of Dermatology, University of California San Francisco, San Francisco, CA USA
| | - S. F. Martin
- Allergy Research Group, Department of Dermatology, University Medical Center Freiburg, Freiburg, Germany
| | - H. F. Merk
- Department of Dermatology and Allergology, University Hospitals Aachen, Aachen, Germany
| | - T. Platzek
- Department of Product Safety, German Federal Institute for Risk Assessment (BfR), Thielallee 88-92, 14195 Berlin, Germany
| | - T. Rustemeyer
- VU University Medical Center, Amsterdam, The Netherlands
| | - A. Schnuch
- Department of Dermatology, University of Göttingen, Göttingen, Germany
| | - R. J. Vandebriel
- National Institute for Public Health and the Environment, Bilthoven, The Netherlands
| | - I. R. White
- St. John’s Institute of Dermatology, St. Thomas’ Hospital, London, UK
| | - A. Luch
- Department of Product Safety, German Federal Institute for Risk Assessment (BfR), Thielallee 88-92, 14195 Berlin, Germany
- Department of Experimental Toxicology and ZEBET, Center for Alternatives to Animal Testing, German Federal Institute for Risk Assessment (BfR), Berlin, Germany
| |
Collapse
|
33
|
Spornraft-Ragaller P, Kämmerer E, Gillitzer C, Schmitt J. Severe allergic reactions to para-phenylenediamine in children and adolescents: should the patch test concentration of PPD be changed? J Dtsch Dermatol Ges 2011; 10:258-64. [PMID: 21812929 DOI: 10.1111/j.1610-0387.2011.07756.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
BACKGROUND Semipermanent henna tattoos containing para-phenylenediamine (PPD) are a well-known cause of severe contact dermatitis, mainly in children. Another relevant exposure source to PPD are hair dyes, which are increasingly used by children and have also been reported to cause intense facial and scalp dermatitis. German patch test guidelines for children recommend that PPD should only be tested in patients who have had a henna tattoo, and then at a reduced concentration of PPD 0.5 % for 24 hours. PATIENTS AND METHODS We report on patch test results in four patients, three children and one adolescent, with a history of contact dermatitis to henna tattoos or hair dye. We used the recommended or even lower patch test concentrations of PPD with 24-hours exposure in all patients. RESULTS AND CONCLUSION All patients showed very strong patch test reactions to PPD and cross-reactions to related compounds even after dilution of PPD to as low as 0.05 %. Therefore, we suggest that in children with a history of allergic reactions to this compound, a titration test should be performed beginning at a concentration of maximal 0.05 %. This procedure has also been proposed previously based on a larger cases series in adults.
Collapse
Affiliation(s)
- Petra Spornraft-Ragaller
- Clinic and Polyclinic for Dermatology, Carl Gustav Carus University Hospital, Technical University Dresden, Fetscherstrasse 74, Dresden, Germany.
| | | | | | | |
Collapse
|
34
|
Spornraft-Ragaller P, Schnuch A, Uter W. Extreme patch test reactivity to p-phenylenediamine but not to other allergens in children. Contact Dermatitis 2011; 65:220-6. [DOI: 10.1111/j.1600-0536.2011.01930.x] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
35
|
Clinical and experimental aspects of allergic contact dermatitis to para-phenylenediamine. Clin Dermatol 2011; 29:316-24. [DOI: 10.1016/j.clindermatol.2010.11.011] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
36
|
Goebel C, Coenraads PJ, Rothe H, Kunze G, Kock M, Schlatter H, Gerberick GF, Blömeke B. Elicitation of the immune response to p-phenylenediamine in allergic patients: the role of dose and exposure time. Br J Dermatol 2010; 163:1205-11. [PMID: 20795999 DOI: 10.1111/j.1365-2133.2010.10009.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND Usage of hair dye products containing p-phenylenediamine (PPD) is a concern for PPD-allergic individuals. OBJECTIVES The present study investigates the role of dose and exposure time on elicitation of allergic contact dermatitis under conditions of permanent hair dyeing. METHODS Elicitation responses after application of a typical hair dye product containing 2% PPD for 30 min followed by rinsing were analysed in 38 PPD-allergic individuals with a documented history of hair dye-related allergy. Skin binding experiments in vitro were performed to distinguish the dose available for elicitation from the dose applied. RESULTS A positive reaction was elicited in 20 of 20 patients with grades ++ to +++ and 12 of 18 with grade + according to the classification of the International Contact Dermatitis Research Group. Under conditions of diagnostic patch testing (48 h exposure), the dose available for elicitation is more than 10-fold higher compared with the dose available for hair dyeing (30-min exposure, rinsing of product). CONCLUSIONS This investigation demonstrates that under simulated hair dye use conditions the actual exposure to PPD is more than an order of magnitude lower than under diagnostic patch testing, although sufficient to elicit a clearly noticeable reaction in 84% of PPD patch test-positive individuals.
Collapse
Affiliation(s)
- C Goebel
- The Procter & Gamble Company, Central Product Safety, Darmstadt, Germany and Cincinnati, OH, USA
| | | | | | | | | | | | | | | |
Collapse
|
37
|
|
38
|
Lysdal SH, Johansen JD. Fragrance contact allergic patients: strategies for use of cosmetic products and perceived impact on life situation. Contact Dermatitis 2009; 61:320-4. [DOI: 10.1111/j.1600-0536.2009.01626.x] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
39
|
Hansen D, Voutsalath M. Contact dermatitis from a presumed allergy to paraphenylenediamine. J Cosmet Dermatol 2009; 8:308-11. [DOI: 10.1111/j.1473-2165.2009.00466.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
40
|
Thyssen JP, Andersen KE, Bruze M, Diepgen T, Giménez-Arnau AM, Gonçalo M, Goossens A, Le Coz C, McFadden J, Rustemeyer T, White IR, White JM, Johansen JD. p-Phenylenediamine sensitization is more prevalent in central and southern European patch test centres than in Scandinavian: results from a multicentre study. Contact Dermatitis 2009; 60:314-9. [PMID: 19489965 DOI: 10.1111/j.1600-0536.2009.01547.x] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND Positive patch test reactions to p-phenylenediamine (PPD) are common. PPD is used in oxidative hair dyes and is also present in dark henna temporary 'tattoos'. Cross-sensitization to other contact allergens may occur. Because subjects sensitized to PPD are at risk of clinically severe reactions upon hair dyeing, there is a need for 'current' prevalence data on PPD sensitization. OBJECTIVES To compare PPD patch test results from dermatitis patients tested between 2003 and 2007 in 10 European patch test centres and to analyse the causes and determine relevance of positive PPD patch test reactions. MATERIALS Patch testing was performed using PPD (1% free base in petrolatum from Trolab (Almirall Hermal GmbH, Reinbeck, Germany) or Chemotechnique (Malmö, Sweden), equivalent to 0.090 mg/cm(2) in the TRUE test from MEKOS Laboratories AS). Statistical analysis was performed using the chi-squared test. RESULTS The weighted average prevalence was 4.6% among 21 515 patients. PPD sensitization occurred more often in centres located in Central and Southern Europe than in Scandinavian centres (odds ratio = 2.40; 95% confidence interval = 2.07-2.78). The overall proportion of positive patch test reactions to PPD that were registered as being of either current or 'past' relevance was high (weighted average 53.6% and 20.3%, respectively). Consumer hair dyeing was the most prominent cause of PPD sensitization (weighted average 41.8%). Furthermore, occupational hair dye exposure (10.6%) and cross-sensitization to textile dyes (12.6%) were frequently reported. CONCLUSIONS PPD sensitization caused by exposure to hair dyes is frequent and remains a present problem for patients visiting contact dermatitis clinics, especially in patch test centres located in Central and Southern Europe.
Collapse
Affiliation(s)
- Jacob Pontoppidan Thyssen
- National Allergy Research Centre, Department of Dermato-Allergology, Gentofte Hospital, University of Copenhagen, DK-2900 Hellerup, Denmark.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Characterization of p-phenylenediamine-albumin binding sites and T-cell responses to hapten-modified protein. J Invest Dermatol 2009; 130:732-42. [PMID: 19710686 DOI: 10.1038/jid.2009.271] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Exposure to p-phenylenediamine (PPD) is associated with the development of T-cell-mediated allergic contact dermatitis. The purpose of this study was to define the nature of the interaction of PPD with the protein and the antigenic determinant that stimulates T cells. Mass spectrometry was employed to show that PPD oxidation products bind irreversibly to cysteine (Cys, position 34) in human serum albumin (HSA). A modified tryptic peptide was characterized with an increase in mass of 106 Da, corresponding to the addition of PPD and not to the secondary products of self conjugation. Lymphocytes from 10 PPD-allergic patients, but not tolerant/naive individuals, were stimulated with PPD and PPD-modified HSA. A total of 70 PPD-specific and 10 PPD-HSA-specific CD4+, CD8+, and CD4+CD8+, Th2-secreting T-cell clones were generated from three allergic patients. In total, 40 clones were stimulated with both PPD and PPD-modified HSA. PPD-modified HSA triggered T-cell responses through a classical hapten mechanism involving processing. Presentation of PPD to several clones was dependent on protein complex formation (42 out of 48) and processing (32 out of 68); however, 12% of clones were triggered with PPD directly. These data identify Cys as the single target for PPD-HSA binding, and show that PPD protein adducts are antigenic determinants in patients with contact dermatitis.
Collapse
|
42
|
Krasteva M, Bons B, Ryan C, Gerberick FG. Consumer Allergy to Oxidative Hair Coloring Products: Epidemiologic Data in the Literature. Dermatitis 2009. [DOI: 10.2310/6620.2009.08089] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
43
|
Abstract
Many women and men now dye their hair. p-Phenylenediamine (PPD) is a frequent and important component of permanent hair dye products; exposure to it may cause allergic contact sensitization, acute dermatitis, and severe facial oedema. To increase our understanding of PPD allergy, we reviewed published literature containing PPD patch test data from dermatitis patients and individuals in the general population. This was performed to estimate the median prevalence and the weighted average of PPD sensitization and thereby assess the burden of PPD-containing hair care products on health. Literature was examined using PubMed-MEDLINE, Biosis, and Science Citation Index. The median prevalence among dermatitis patients was 4.3% in Asia, 4% in Europe, and 6.2% in North America. A widespread increase in the prevalence of PPD sensitization was observed among Asian dermatitis patients. In Europe, a decrease in the 1970s was replaced by a plateau with steady, high prevalences ranging between 2% and 6%. The prevalence remained high in North America, although a decreasing tendency was observed. Contact allergy to PPD is an important health issue for both women and men. More stringent regulation and enforcement are required as public health measures to reduce the burden of disease that exposure to PPD has brought to populations.
Collapse
Affiliation(s)
- Jacob Pontoppidan Thyssen
- National Allergy Research Centre, Department of Dermatology, Gentofte University Hospital, Ledreborg Allé 40, 1. Gentofte 2820, Denmark.
| | | | | |
Collapse
|
44
|
Farrell J, Jenkinson C, Lavergne SN, Maggs JL, Kevin Park B, Naisbitt DJ. Investigation of the immunogenicity of p-phenylenediamine and Bandrowski's base in the mouse. Toxicol Lett 2008; 185:153-9. [PMID: 19136049 DOI: 10.1016/j.toxlet.2008.12.008] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2008] [Revised: 12/10/2008] [Accepted: 12/12/2008] [Indexed: 10/21/2022]
Abstract
p-Phenylenediamine (PPD) exposure is associated with T-cell mediated contact dermatitis. T-cells from allergic patients proliferate following exposure to PPD and the oxido-conjugation product Bandrowski's base (BB). Both compounds are classified as sensitizers in the local lymph node assay; however, because of their instability the nature of the antigenic determinant remains ill-defined. The aim of this study was to explore the immunogenic potential of PPD and BB in mice. Spleen cell proliferation and cytokine secretion was measured ex vivo following antigen recall with soluble PPD or BB and either irradiated or glutaraldehyde fixed, antigen pulsed dendritic cells from syngeneic mice. Glutathione was added to certain incubations. LC-MS analysis and solvent extraction were used to monitor the fate of [(14)C]BB in culture and the extent of BB binding, respectively. Spleen cells from BB exposed, but not PPD- or vehicle-exposed, mice proliferated when stimulated with BB. Proliferating cells secreted high levels of IFN-gamma, GM-CSF and IL-2. Stimulation with PPD instigated low levels of proliferation. Irradiated, but not fixed, dendritic cells pulsed with BB stimulated proliferation signifying a classical hapten mechanism involving irreversible BB binding to protein and processing. BB bound preferentially to serum protein when incubated together with cells and serum. Degradation of BB in the presence of glutathione was associated with a stronger stimulation of specific T-cells at higher BB concentrations. These data demonstrate that BB is a potent immunogen in the mouse.
Collapse
Affiliation(s)
- John Farrell
- MRC Centre for Drug Safety Science, Department of Pharmacology and Therapeutics, The Sherrington Building, Ashton Street, The University of Liverpool, Liverpool L69 3GE, UK
| | | | | | | | | | | |
Collapse
|
45
|
Aeby P, Sieber T, Beck H, Gerberick GF, Goebel C. Skin sensitization to p-phenylenediamine: the diverging roles of oxidation and N-acetylation for dendritic cell activation and the immune response. J Invest Dermatol 2008; 129:99-109. [PMID: 18704111 DOI: 10.1038/jid.2008.209] [Citation(s) in RCA: 88] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Skin is a target of allergic reactions to aromatic amine hair dye precursors, such as p-phenylenediamine (PPD). As conversion of PPD on or in the skin is expected to be required for the induction of allergic contact dermatitis, we analyzed the role of oxidation and N-acetylation as major transformation steps. PPD and its oxidative and N-acetylated derivatives were tested for their sensitizing potential in vitro using a dendritic cell (DC) activation assay and in vivo using the local lymph node assay (LLNA). PPD did not induce relevant DC activation but induced a positive LLNA response. In contrast, DC activation was obtained when PPD was chemically pre-oxidized or after air oxygen exposure. Under both conditions, the potent sensitizing PPD oxidation product Bandrowski's base was identified along with other di- and trimeric species, indicating that PPD oxidation products provide an effective immune stimulation (danger signal). In contrast mono- and diacetylated PPD did not induce DC activation or a positive LLNA response. We conclude that dermal N-acetylation of PPD competes with the formation of oxidized PPD whereas skin exposure conditions allowing auto-oxidation, as in the LLNA, provide an effective danger signal necessary to induce skin sensitization to PPD.
Collapse
Affiliation(s)
- Pierre Aeby
- Procter and Gamble Co., Wella-Cosmital, Marly, Switzerland
| | | | | | | | | |
Collapse
|
46
|
Schnuch A, Lessmann H, Frosch P, Uter W. para-Phenylenediamine: the profile of an important allergen. Results of the IVDK1. Br J Dermatol 2008; 159:379-86. [DOI: 10.1111/j.1365-2133.2008.08644.x] [Citation(s) in RCA: 88] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
47
|
Abstract
Genetic factors presumably play a role in contact allergy (CA). There is, however, a lack of conclusive evidence from clinical studies. This may be on account of the strongly competing or modifying impact of exogenous factors, namely the potency of allergens and the intensity of exposure, and the fact that - in principle - everybody can be sensitized. Regarding phenotype, in contrast, polysensitization (PS) seems to indicate a subset of individuals at greater risk. In human sensitization experiments with dinitrochlorobenzene, induction was facilitated in PS, and elicitation enhanced. Recent clinical epidemiological data, taking confounders for PS, such as age, sex, and other skin diseases into account, demonstrated the following: (i) PS was the greatest risk factor to be sensitized to a number of (even weak) index allergens, indicating higher susceptibility on the level of induction; (ii) patch test reactions in PS patients were generally stronger indicating higher susceptibility on the level of elicitation. These findings are complemented by reports on polymorphisms of TNF-alpha and IL-16 in PS patients. Future studies on the genetics of CA should be performed in subgroups with PS, focussing on polymorphisms relevant for CA-specific and nonspecific (inflammatory) processes.
Collapse
Affiliation(s)
- A Schnuch
- Center of the Information Network of Department of Dermatology, Institute at University of Göttingen, Göttingen, Germany
| | | | | |
Collapse
|
48
|
White JML, Gilmour NJ, Jeffries D, Duangdeeden I, Kullavanijaya P, Basketter DA, McFadden JP. A general population from Thailand: incidence of common allergens with emphasis on para-phenylenediamine. Clin Exp Allergy 2007; 37:1848-53. [DOI: 10.1111/j.1365-2222.2007.02846.x] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
49
|
White JML, Basketter DA, Pease CK, Sanders DA, McFadden JP. Intermittent exposure to low-concentration paraphenylenediamine can be equivalent to single, higher-dose exposure. Contact Dermatitis 2007; 56:262-5. [PMID: 17441847 DOI: 10.1111/j.1600-0536.2007.01072.x] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Hair dye allergy is an important and increasingly common cause of allergic contact dermatitis. The role of repeated exposure in elicitation of allergy has not previously been extensively studied. We have therefore compared elicitation between single and intermittent exposure to paraphenylenediamine (PPD). 23 subjects known to be allergic to PPD from positive patch tests were exposed to 0.3% and 0.03% PPD, both in petrolatum and water, for 5 min at the same site every day for up to 8 D. In the same subjects, single exposures were also performed at different sites, from 5 to 40 min. Other experiments exposed rat skin to radiolabelled PPD as one-off application or multiple exposures. There were 8 reactions in the cumulative exposure site using 0.3% PPD in aqueous solution. In 7 of these, there was an exact correlation with reaction to the cumulative time needed for repeat exposures to elicit a reaction and the time needed for a reaction to the single exposure. There were no reactions to 0.03% PPD in water or pet under either type of exposure condition. There was also a positive correlation between grade of original reaction in clinic (+++, ++, +) and appearance/intensity of elicitation reactions. In the animal study, cumulative time and single exposure time sites correlated with regards to retention of radiolabelled substance within the skin. This study therefore demonstrates for the first time that, over the time period tested, the allergenic component of PPD accumulates in the skin. Hence, intermittent exposure to lower concentrations of PPD may be equivalent to higher concentration, one-off exposure.
Collapse
|
50
|
Jowsey IR, Basketter DA, McFadden JP, Kullavanijaya P, Duangdeeden I. Elicitation response characteristics to permanent hair dye in paraphenylenediamine-allergic volunteers. Contact Dermatitis 2006; 55:330-4. [PMID: 17101006 DOI: 10.1111/j.1600-0536.2006.00984.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Elicitation response characteristics to complete permanent hair dye products in paraphenylenediamine (PPD)-allergic volunteers have not previously been explored in detail. OBJECTIVES To assess the elicitation response characteristics observed in PPD-allergic volunteers upon patch testing with complete hair dyes. METHODS PPD-allergic volunteers were assigned to 1 of 3 groups depending upon whether they elicited + (group 1), ++ (group 2) or +++ (group 3) reactions following the standard diagnostic procedure. Each group was subsequently patch tested with 2 complete hair dyes (A and B) for 30 min, 1 hr and 24 hr. Patch sites were examined 1 day, 2 days and 3 days after patch removal. RESULTS Exposure to either hair dye for 30 min or 1 hr was insufficient to yield positive patch test reactions in all of the PPD-allergic patients in groups 1 or 2. Application of either hair dye for 24 hr was sufficient to yield positive reactions in all of the individuals within groups 2 and 3. CONCLUSIONS The frequency of positive patch test reactions observed following 24-hr exposure to complete permanent hair dyes is comparable to that observed following 48-hr exposure to 1% PPD/petrolatum in those individuals whose degree of sensitization is such that they typically present ++ or +++ reactions diagnostically.
Collapse
Affiliation(s)
- Ian R Jowsey
- Unilever Safety and Environmental Assurance Centre, Colworth Park, Sharnbrook, Bedfordshire MK44 1LQ, UK.
| | | | | | | | | |
Collapse
|