1
|
Sakamoto S, Shimizu S, Uchida H, Fukuda A, Kasahara M. Portal vein pressure and flow modulation in pediatric liver transplantation. Pediatr Transplant 2023; 27:e14563. [PMID: 37470148 DOI: 10.1111/petr.14563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Accepted: 06/23/2023] [Indexed: 07/21/2023]
Abstract
Liver transplantation (LT) has been indicated for smaller and more clinically severe patients in recent years. Small biliary atresia (BA) patients often show portal hypoplasia and sclerotic portal vein (PV), which may make PV reconstruction more difficult during the operation. Among PV complications, intraoperative PV thrombosis can be considered a disaster, and it is important to prevent this catastrophic event by the precise assessment of the PV structure and PVF using radiological imaging before and during LT. However, there are no objective parameters to indicate whether sufficient PVF can be obtained. PV pressure (PVP) and PV flow (PVF) have mainly been studied in adult living donor LT, for the purpose of preventing small-for-size syndrome, and PVP has been considered an objective parameter of graft inflow modulation (GIM). In the setting of pediatric LT, GIM is mainly performed to prevent hypoperfusion, and it must be performed before graft implantation. GIM to maximize the PVF of pediatric patients with potentially low PVF in LT consists of the interruption of collateral vessels, the assessment of the usability of the native PV, and technical modifications in PV reconstruction. Reliable objective parameters that represent sufficient PVF before graft implantation are desired. Our recent study proposed that a PVP of ≥25 mmHg before graft implantation can be considered an objective parameter to obtain sufficient PVF (cutoff value: 50 mL/min/100 g of graft weight). Further investigation is needed to determine the best strategy for successful PV reconstruction in pediatric LT.
Collapse
Affiliation(s)
- Seisuke Sakamoto
- Organ Transplantation Center, National Center for Child Health and Development, Tokyo, Japan
| | - Seiichi Shimizu
- Organ Transplantation Center, National Center for Child Health and Development, Tokyo, Japan
| | - Hajime Uchida
- Organ Transplantation Center, National Center for Child Health and Development, Tokyo, Japan
| | - Akinari Fukuda
- Organ Transplantation Center, National Center for Child Health and Development, Tokyo, Japan
| | - Mureo Kasahara
- Organ Transplantation Center, National Center for Child Health and Development, Tokyo, Japan
| |
Collapse
|
2
|
Treatments and outcomes of intra-operative portal vein thrombosis in living-donor liver transplantation due to biliary atresia. J Pediatr Surg 2022; 57:947-954. [PMID: 35810021 DOI: 10.1016/j.jpedsurg.2022.06.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 06/03/2022] [Accepted: 06/13/2022] [Indexed: 11/20/2022]
Abstract
BACKGROUND Pediatric living-donor liver transplantation (LDLT) has become one of the most effective therapies for pediatric end-stage liver diseases. We aim to investigate the risk factors for intra-operative portal vein thrombosis (PVT) and the short- and long-term outcomes in children post LDLT. METHODS This was a retrospective analysis from 584 cases of biliary atresia (BA) patients who had undergone LDLT from January 2014 to December 2019 at our hospital. Patients were divided into PVT and non-PVT groups according to the occurrence of PVT during LDLT. RESULTS The median age of recipients at transplantation was 7.22 (quartiles, 6.03, 9.50) months, the incidence of intra-operative PVT was 5.31% (31/584). The independent risk factors for intra-operative PVT were the diameter of the recipient's PV not greater than 4 mm and a higher ratio of graft-to-recipient PV diameter. The cumulative survival rates of grafts and recipients were 93.5% and 93.5% in the PVT group, and 94.9% and 95.3% in the non-PVT group, respectively, without significant difference. The recovery of graft function was similar in recipients with or without interposed graft vessel (IGV). However, the incidence of PV stenosis was higher in recipients with IGV after LDLT. CONCLUSION Intra-operative PVT is a common complication in pediatric LDLT, but an excellent prognosis can be achieved by appropriate and individualized surgical treatment. We noted that intra-operative PVT did not affect the survival rates of grafts and recipients, but there was a higher incidence of PV complications after LDLT. LEVEL OF EVIDENCE Ⅲ.
Collapse
|
3
|
Stevens JP, Xiang Y, Leong T, Naik K, Gupta NA. Portal vein complications and outcomes following pediatric liver transplantation: Data from the Society of Pediatric Liver Transplantation. Liver Transpl 2022; 28:1196-1206. [PMID: 35092344 DOI: 10.1002/lt.26412] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 01/06/2022] [Accepted: 01/11/2022] [Indexed: 12/29/2022]
Abstract
Children who undergo liver transplantation are at risk for portal vein complications (PVCs) including thrombosis (PVT) and stenosis (PVS). Using multicenter data from the Society of Pediatric Liver Transplantation, we analyzed the prevalence, timing, and risk factors for PVC following a first liver transplantation, and assessed the potential impact of PVC on patient outcomes. Our cohort included 4278 patients, of whom 327 (7.6%) developed PVC. Multivariate analysis discovered several factors independently associated with PVC: younger recipient age, lower weight at time of transplantation, diagnosis of biliary atresia (BA), receiving a technical variant graft (TVG), warm ischemia time over 3 h, PVT in the recipient's pretransplantation native liver, and concurrent hepatic artery thrombosis (all p < 0.05). Subgroup analysis of those with BA found higher prevalence in patients transplanted at less than 2 years of age and those with TVGs. There was no difference in PVC prevalence among patients with BA with vs. without prior Kasai portoenterostomy. Most PVT (77.7%) presented within 90 days after transplantation. Patients with PVC had a higher risk of graft failure (23.9% vs. 8.3%; adjusted hazard ratio [HR], 3.08; p < 0.001) and a higher risk of death (16.4% vs. 8.9%; adjusted HR, 1.96; p = 0.01). Recurrence after retransplantation was similar to the overall prevalence in the cohort (8.2%). Our results recognize the common occurrence of PVC following pediatric liver transplantation, describe independently associated risk factors, and determine that patients with PVC have worse outcomes. Further studies are needed to improve PVC prevention, detection, and management strategies.
Collapse
Affiliation(s)
- James P Stevens
- Department of Pediatrics, Emory University School of Medicine, Atlanta, Georgia, USA.,Transplant Services, Children's Healthcare of Atlanta, Atlanta, Georgia, USA
| | - Yijin Xiang
- Department of Pediatrics, Emory University School of Medicine, Atlanta, Georgia, USA
| | - Traci Leong
- Department of Pediatrics, Emory University School of Medicine, Atlanta, Georgia, USA.,Biostatistics and Bioinformatics, Rollins School of Public Health, Emory University, Atlanta, Georgia, USA
| | - Kushal Naik
- Transplant Services, Children's Healthcare of Atlanta, Atlanta, Georgia, USA.,Department of Epidemiology, Rollins School of Public Health, Emory University, Atlanta, Georgia, USA
| | - Nitika Arora Gupta
- Department of Pediatrics, Emory University School of Medicine, Atlanta, Georgia, USA.,Transplant Services, Children's Healthcare of Atlanta, Atlanta, Georgia, USA
| |
Collapse
|
4
|
P4 Stump Approach for Intraoperative Portal Vein Stenting in Pediatric Living Donor Liver Transplantation: An Innovative Technique for a Challenging Problem. Ann Surg 2019. [PMID: 28632515 DOI: 10.1097/sla.0000000000002333] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
OBJECTIVE The aim of this study was to evaluate the utility of the P4 stump stenting approach for treating portal vein (PV) complications in pediatric living donor liver transplantation (LDLT). BACKGROUND PV complications cause significant morbidity and mortality in pediatric LDLT. Biliary atresia in the backdrop of pathological PV hypoplasia and sclerosis heightens the complexity of PV reconstruction. The authors developed a novel approach for intraoperative PV stenting via the graft segment 4 PV stump (P4 stump) to address this challenge. METHODS From April 2009 to December 2016, 15 pediatric LDLT recipients (mean age 10.3 ± 5.0 months, mean graft-recipient weight ratio 3.70%) underwent intraoperative stenting for suboptimal PV flow (<10 cm/s) or PV occlusion after collateral ligation and graft repositioning. Under portography, metallic stents were deployed via the reopened P4 stump of the left lateral segment grafts. RESULTS PV diameter and peak flow increased significantly after stent placement (2.93 ± 1.74 to 7.01 ± 0.91 mm and 2.0 ± 9.2 to 17.3 ± 3.5 cm/s, respectively, P = 0.001 for both), and there were no technical failures. Stents in all surviving patients remained patent up to 8 years (mean 27.7 months), with no vascular or biliary complications. After implementation of the P4 approach, the incidence of variceal bleeding as a late complication decreased from 7% to zero. CONCLUSION The P4 stump stenting approach affords procedural convenience, ease of manipulation, and consistent results with the potential for excellent long-term patency in children despite continued growth. This technique obviates the need for more demanding post-transplant stenting, and may become a substitute for complicated revision surgery, portosystemic shunting, or retransplantation.
Collapse
|
5
|
Feng M, Wan P, Qiu B, Zhou T, Luo Y, Gu L, Chi J, Zhong C, Lu Y, Zhang J, Xia Q. Improved portal vein venoplasty with an autogenous patch in pediatric living donor liver transplantation. Liver Transpl 2018; 24:1084-1090. [PMID: 29328523 DOI: 10.1002/lt.25011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Revised: 12/27/2017] [Accepted: 01/08/2018] [Indexed: 12/26/2022]
Abstract
A stenotic or hypoplastic portal vein (PV) represents a challenge for PV reconstruction in pediatric living donor liver transplantation (LDLT). Several PV venoplastic techniques have been developed. However, we still seek improved venoplastic techniques with better efficacy and compatibility. From June 2016 to July 2017, 271 LDLT procedures were performed at the Department of Liver Surgery, Renji Hospital. A total of 16 consecutive children with stenotic and sclerotic PVs underwent a novel technique-the autogenous PV patch plastic technique. Vessel patches were procured from the left branch (LB), or the bifurcation of the right branch and LB of the PV in the native liver. Then, the PVs were enlarged by suturing the patches along the longitudinal axis from the confluence of the PV and coronary vein (CV). In this series, 15/16 achieved good intraoperational PV flow, and 1 showed low PV flow but was treated with stent placement. Within a median follow-up of 11 months (1-18 months), 15 patients were alive and had normal graft function, whereas 1 child died from lung infection 1 month after transplantation. No PV complications were detected. In conclusion, the autogenous patch venoplasty technique using the PV-CV confluence is simple and safe. This novel venoplastic reconstruction technique could serve as a surgical option to achieve satisfactory outcomes, especially those with stenotic PV (<4.5 mm) and dilated CV (>3.0 mm). Liver Transplantation 2018 AASLD.
Collapse
Affiliation(s)
- Mingxuan Feng
- Departments of Liver Surgery, Renji Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
| | - Ping Wan
- Departments of Liver Surgery, Renji Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
| | - Bijun Qiu
- Departments of Liver Surgery, Renji Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
| | - Tao Zhou
- Departments of Liver Surgery, Renji Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
| | - Yi Luo
- Departments of Liver Surgery, Renji Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
| | - Lihong Gu
- Ultrasonography, Renji Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
| | - Jiachang Chi
- Department of Interventional Oncology, Renji Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
| | - Chengpeng Zhong
- Departments of Liver Surgery, Renji Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
| | - Yefeng Lu
- Departments of Liver Surgery, Renji Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
| | - Jianjun Zhang
- Departments of Liver Surgery, Renji Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
| | - Qiang Xia
- Departments of Liver Surgery, Renji Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China
| |
Collapse
|
6
|
Gu L, Fang H, Zhang S, Chi J, Li F, Xia Q. Intra-operative portal hemodynamics in pediatric LDLT: Doppler ultrasound surveillance. Pediatr Transplant 2018; 22:e13200. [PMID: 29696749 DOI: 10.1111/petr.13200] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 03/23/2018] [Indexed: 01/10/2023]
Abstract
Doppler ultrasonography is useful in monitoring intra-operative PV flow in LDLT. A retrospective cohort study included 550 pediatric recipients (<18 years) who underwent LDLT from October 2006 to August 2016 in our hospital. A total of 33 recipients (incidence 6%) were found to have insufficient intra-operative PV flow after PV reperfusion. The treatments included intra-operative stent placement (n=25), anticoagulation (n=3), thrombectomy and re-anastomosis (n=2), graft repositioning (n=1), collateral ligation (n=1), and replaced PV (n=1). The peak PV velocity, HAPSV, HARI, and HV velocity before and after the interventions were significantly improved 0(0,5.5) cm/s vs. 37.36±15.30 cm/s, 38.68±8.92 cm/s vs. 62.30±16.97 cm/s, 0.55±0.08 vs. 0.76±0.10, and 32.37±10.33 cm/s vs. 40.94±15.01 cm/s, respectively (P<.01). Insufficient PV flow and decreased HARI are two significant criteria indicating need for intra-operative PV management. Dramatic changes in the hepatic hemodynamics were detected after proper treatment. Immediate resolution of PV flow is feasible in pediatric LDLT.
Collapse
Affiliation(s)
- Lihong Gu
- Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Hua Fang
- Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Shijun Zhang
- Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Jiachang Chi
- Department of Interventional Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Fenghua Li
- Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Qiang Xia
- Department of Liver Surgery, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
7
|
Stanescu AL, Kamps SE, Dick AAS, Parisi MT, Phillips GS. Intraoperative Doppler sonogram in pediatric liver transplants: a pictorial review of intraoperative and early postoperative complications. Pediatr Radiol 2018; 48:401-410. [PMID: 29273893 DOI: 10.1007/s00247-017-4053-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Revised: 11/12/2017] [Accepted: 12/05/2017] [Indexed: 01/10/2023]
Abstract
A spectrum of vascular complications can be seen in pediatric liver transplant patients, including occlusion and hemodynamically significant narrowing of the vessels that provide inflow to or outflow from the graft. Intraoperative Doppler ultrasound (US) has the potential benefit of identifying vascular complications in pediatric liver transplant patients prior to abdominal closure. Importantly, intraoperative Doppler US can be used as a problem-solving tool in situations such as position-dependent kinking of the portal or hepatic veins, or in suspected vasospasm of the hepatic artery. Furthermore, this technique can be used for real-time reassessment after surgical correction of vascular complications. This pictorial review of intraoperative Doppler US in pediatric liver transplant patients illustrates normal findings and common vascular complications, including examples after surgical correction, in the perioperative period.
Collapse
Affiliation(s)
- A Luana Stanescu
- Department of Radiology, Seattle Children's Hospital, University of Washington School of Medicine, 4800 Sand Point Way NE, Seattle, WA, 98105, USA
| | - Shawn E Kamps
- Department of Radiology, Seattle Children's Hospital, University of Washington School of Medicine, 4800 Sand Point Way NE, Seattle, WA, 98105, USA
| | - André A S Dick
- Department of Surgery, Section of Pediatric Transplant, Seattle Children's Hospital, University of Washington School of Medicine, Seattle, WA, 98105, USA
| | - Marguerite T Parisi
- Department of Radiology, Seattle Children's Hospital, University of Washington School of Medicine, 4800 Sand Point Way NE, Seattle, WA, 98105, USA.,Department of Pediatrics, Seattle Children's Hospital, University of Washington School of Medicine, Seattle, WA, 98105, USA
| | - Grace S Phillips
- Department of Radiology, Seattle Children's Hospital, University of Washington School of Medicine, 4800 Sand Point Way NE, Seattle, WA, 98105, USA.
| |
Collapse
|
8
|
Reddy MS, Rela M. Portosystemic collaterals in living donor liver transplantation: What is all the fuss about? Liver Transpl 2017; 23:537-544. [PMID: 28073180 DOI: 10.1002/lt.24719] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2016] [Revised: 12/18/2016] [Accepted: 12/21/2016] [Indexed: 02/07/2023]
Abstract
Portosystemic collaterals are a common finding in patients with cirrhosis undergoing liver transplantation. Recently, there has been a renewed interest regarding their significance in the setting of living donor liver transplantation (LDLT) due to concerns of graft hypoperfusion or hyperperfusion and its impact on early posttransplant outcomes. Presence of these collaterals has greater significance in the LDLT setting when compared with the deceased donor liver transplantation setting as dictated by the difference in the physiology of partial liver grafts. We discuss current thinking of portal flow dynamics and the techniques for dealing with this clinical problem. Liver Transplantation 23 537-544 2017 AASLD.
Collapse
Affiliation(s)
- Mettu Srinivas Reddy
- Institute of Liver Disease and Transplantation, Gleneagles Global Hospital, Chennai, India
| | - Mohamed Rela
- Institute of Liver Disease and Transplantation, Gleneagles Global Hospital, Chennai, India.,National Foundation for Liver Research, Chennai, India.,Institute of Liver Studies, King's College Hospital, London, UK
| |
Collapse
|
9
|
Abdelaziz O, Attia H. Doppler ultrasonography in living donor liver transplantation recipients: Intra- and post-operative vascular complications. World J Gastroenterol 2016; 22:6145-72. [PMID: 27468207 PMCID: PMC4945976 DOI: 10.3748/wjg.v22.i27.6145] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2016] [Revised: 05/18/2016] [Accepted: 06/13/2016] [Indexed: 02/06/2023] Open
Abstract
Living-donor liver transplantation has provided a solution to the severe lack of cadaver grafts for the replacement of liver afflicted with end-stage cirrhosis, fulminant disease, or inborn errors of metabolism. Vascular complications remain the most serious complications and a common cause for graft failure after hepatic transplantation. Doppler ultrasound remains the primary radiological imaging modality for the diagnosis of such complications. This article presents a brief review of intra- and post-operative living donor liver transplantation anatomy and a synopsis of the role of ultrasonography and color Doppler in evaluating the graft vascular haemodynamics both during surgery and post-operatively in accurately defining the early vascular complications. Intra-operative ultrasonography of the liver graft provides the surgeon with useful real-time diagnostic and staging information that may result in an alteration in the planned surgical approach and corrections of surgical complications during the procedure of vascular anastomoses. The relevant intra-operative anatomy and the spectrum of normal and abnormal findings are described. Ultrasonography and color Doppler also provides the clinicians and surgeons early post-operative potential developmental complications that may occur during hospital stay. Early detection and thus early problem solving can make the difference between graft survival and failure.
Collapse
|