Leung WS, Wu VWC, Liu CYW, Cheng ACK. A dosimetric comparison of the use of equally spaced beam (ESB), beam angle optimization (BAO), and volumetric modulated arc therapy (VMAT) in head and neck cancers treated by intensity modulated radiotherapy. J Appl Clin Med Phys 2019; 20:121-130. [PMID: 31593367 PMCID: PMC6839392 DOI: 10.1002/acm2.12748] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Revised: 09/02/2019] [Accepted: 09/13/2019] [Indexed: 11/17/2022] Open
Abstract
Introduction Previous studies have shown that the beam arrangement had significant influence on plan quality in intensity modulated radiotherapy (IMRT). This study aimed to evaluate the dosimetric performance of beam arrangement methods by employing equally spaced beams (ESB), beam angle optimization (BAO), and volumetric modulated arc therapy (VMAT) in the planning of five types of head and neck (H&N) cancers treated by IMRT. Methods Five plans of different beam arrangement methods were optimized for 119 H&N cancer patients with the prescription of 66–70 Gy for high‐risk planning target volume (PTV), 60 Gy for intermediate risk PTV, 54 Gy for low‐risk PTV using a simultaneously integrated boost method. The five‐beam arrangement methods were: ESB, coplanar BAO (BAOc), noncoplanar BAO (BAOnc), two‐arc VMAT (VMAT2), and three‐arc VMAT (VMAT3). The H&N cancers included cancers of nasopharynx, oral cavity, larynx, maxillary sinus, and parotid. Although the partial arc VMAT could be used in cases where the PTVs were situated at one side of the head such as the parotid, this arrangement was not included because it was intended to include only the beam arrangements that were applicable to all the types of head and neck cancers in the study. The plans were evaluated using a “figure‐of‐merit” known as uncomplicated target conformity index (UTCI). In addition, PTV conformation number and homogeneity index, normal tissue integral dose, and organ at risk (OAR) doses were also used. The mean values of these parameters were compared among the five plans. Results All treatment plans met the preset dose requirements for the target volumes and OARs. For nasopharyngeal cancer, VMAT3 and BAOnc demonstrated significantly higher UTCI. For cancer of oral cavity, most beam arrangement showed similar UTCI except ESB, which was relatively lower. For cancer of larynx, there was no significant difference in UTCI among the five‐beam arrangement methods. For cancers of maxillary sinus and parotid gland, the two BAO methods showed marginally higher UTCI among all the five methods. Conclusion Individual methods showed dosimetric advantages on certain aspects, and the UTCI of the BAO treatment plans are marginally greater in the case of maxillary sinus and parotid gland. However, if treatment time was included into consideration, VMAT plans would be recommended for cancers of the nasopharynx, oral cavity, and larynx.
Collapse
Affiliation(s)
- Wan Shun Leung
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Kowloon, Hong Kong
| | - Vincent W C Wu
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Kowloon, Hong Kong
| | - Clarie Y W Liu
- Department of Oncology, Princess Margaret Hospital, Kowloon, Hong Kong
| | - Ashley C K Cheng
- Department of Oncology, Princess Margaret Hospital, Kowloon, Hong Kong
| |
Collapse
|
2
|
Lu JY, Lin Z, Zheng J, Lin PX, Cheung MLM, Huang BT. Dosimetric evaluation of a simple planning method for improving intensity-modulated radiotherapy for stage III lung cancer. Sci Rep 2016; 6:23543. [PMID: 27009235 PMCID: PMC4806372 DOI: 10.1038/srep23543] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2015] [Accepted: 03/09/2016] [Indexed: 02/05/2023] Open
Abstract
This study aimed to evaluate the dosimetric outcomes of a base-dose-plan-compensation (BDPC) planning method for improving intensity-modulated radiotherapy (IMRT) for stage III lung cancer. For each of the thirteen included patients, three types of planning methods were applied to obtain clinically acceptable plans: (1) the conventional optimization method (CO); (2) a split-target optimization method (STO), in which the optimization objectives were set higher dose for the target with lung density; (3) the BDPC method, which compensated for the optimization-convergence error by further optimization based on the CO plan. The CO, STO and BDPC methods were then compared regarding conformity index (CI), homogeneity index (HI) of the target, organs at risk (OARs) sparing and monitor units (MUs). The BDPC method provided better HI/CI by 54%/7% on average compared to the CO method and by 38%/3% compared to the STO method. The BDPC method also spared most of the OARs by up to 9%. The average MUs of the CO, STO and BDPC plans were 890, 937 and 1023, respectively. Our results indicated that the BDPC method can effectively improve the dose distribution in IMRT for stage III lung cancer, at the expense of more MUs.
Collapse
Affiliation(s)
- Jia-Yang Lu
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong, China
| | - Zhu Lin
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong, China
| | - Jing Zheng
- Department of Laboratory, Shantou Central Hospital, Affiliated Shantou Hospital of Sun Yat-sen University, Shantou, Guangdong, China
| | - Pei-Xian Lin
- Department of Nosocomial Infection Management, the Second Affiliated Hospital of Shantou University Medical College, Shantou, Guangdong, China
| | | | - Bao-Tian Huang
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong, China
| |
Collapse
|
3
|
A simple optimization approach for improving target dose homogeneity in intensity-modulated radiotherapy for sinonasal cancer. Sci Rep 2015; 5:15361. [PMID: 26497620 PMCID: PMC4620500 DOI: 10.1038/srep15361] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2015] [Accepted: 09/25/2015] [Indexed: 02/05/2023] Open
Abstract
Homogeneous target dose distribution in intensity-modulated radiotherapy (IMRT) for sinonasal cancer (SNC) is challenging to achieve. To solve this problem, we established and evaluated a basal-dose-compensation (BDC) optimization approach, in which the treatment plan is further optimized based on the initial plans. Generally acceptable initial IMRT plans for thirteen patients were created and further optimized individually by (1) the BDC approach and (2) a local-dose-control (LDC) approach, in which the initial plan is further optimized by addressing hot and cold spots. We compared the plan qualities, total planning time and monitor units (MUs) among the initial, BDC, LDC IMRT plans and volumetric modulated arc therapy (VMAT) plans. The BDC approach provided significantly superior dose homogeneity/conformity by 23%-48%/6%-9% compared with both the initial and LDC IMRT plans, as well as reduced doses to the organs at risk (OARs) by up to 18%, with acceptable MU numbers. Compared with VMAT, BDC IMRT yielded superior homogeneity, inferior conformity and comparable overall OAR sparing. The planning of BDC, LDC IMRT and VMAT required 30, 59 and 58 minutes on average, respectively. Our results indicated that the BDC optimization approach can achieve significantly better dose distributions with shorter planning time in the IMRT for SNC.
Collapse
|
4
|
Lu JY, Wu LL, Zhang JY, Zheng J, Cheung MLM, Ma CC, Xie LX, Huang BT. Improving target dose coverage and organ-at-risk sparing in intensity-modulated radiotherapy of advanced laryngeal cancer by a simple optimization technique. Br J Radiol 2015; 88:20140654. [PMID: 25494885 PMCID: PMC4614243 DOI: 10.1259/bjr.20140654] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2014] [Revised: 12/02/2014] [Accepted: 12/11/2014] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVE To evaluate a simple optimization technique intended to improve planning target volume (PTV) dose coverage and organ-at-risk (OAR) sparing in intensity-modulated radiotherapy (IMRT) of advanced laryngeal cancer. METHODS Generally acceptable initial IMRT plans were generated for 12 patients and were improved individually by the following two techniques: (1) base dose function-based (BDF) technique, in which the treatment plans were reoptimized based on the initial IMRT plans; (2) dose-controlling structure-based (DCS) technique, in which the initial IMRT plans were reoptimized by adding constraints for hot and cold spots. The initial, BDF and DCS IMRT plans and additionally generated volumetric modulated arc therapy (VMAT) plans were compared concerning homogeneity index (HI) and conformity index (CI) of PTVs prescribed at 70 Gy/60 Gy (PTV70/PTV60), OAR sparing, monitor units (MUs) per fraction and total planning time. RESULTS Compared with the initial IMRT and DCS IMRT plans, the BDF technique provided superior HI/CI, by approximately 19-37%/4-11%, and lower doses to most OARs, by approximately 1-7%, except for the comparable HI of PTV60 to DCS IMRT plans. Compared with VMAT plans, the BDF technique provided comparable HI, CI and most-OAR sparing, except for the superior HI of PTV70, by approximately 13%. The BDF technique produced more MUs and reduced the planning time. CONCLUSION The BDF optimization technique for IMRT of advanced laryngeal cancer can improve target dose homogeneity and conformity, spare most OARs and is efficient. ADVANCES IN KNOWLEDGE A novel optimization technique for improving IMRT was assessed and found to be effective and efficient.
Collapse
Affiliation(s)
- J-Y Lu
- 1 Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, China
| | | | | | | | | | | | | | | |
Collapse
|
5
|
Lu JY, Cheung MLM, Huang BT, Wu LL, Xie WJ, Chen ZJ, Li DR, Xie LX. Improving target coverage and organ-at-risk sparing in intensity-modulated radiotherapy for cervical oesophageal cancer using a simple optimisation method. PLoS One 2015; 10:e0121679. [PMID: 25768733 PMCID: PMC4358965 DOI: 10.1371/journal.pone.0121679] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2014] [Accepted: 02/03/2015] [Indexed: 02/05/2023] Open
Abstract
PURPOSE To assess the performance of a simple optimisation method for improving target coverage and organ-at-risk (OAR) sparing in intensity-modulated radiotherapy (IMRT) for cervical oesophageal cancer. METHODS For 20 selected patients, clinically acceptable original IMRT plans (Original plans) were created, and two optimisation methods were adopted to improve the plans: 1) a base dose function (BDF)-based method, in which the treatment plans were re-optimised based on the original plans, and 2) a dose-controlling structure (DCS)-based method, in which the original plans were re-optimised by assigning additional constraints for hot and cold spots. The Original, BDF-based and DCS-based plans were compared with regard to target dose homogeneity, conformity, OAR sparing, planning time and monitor units (MUs). Dosimetric verifications were performed and delivery times were recorded for the BDF-based and DCS-based plans. RESULTS The BDF-based plans provided significantly superior dose homogeneity and conformity compared with both the DCS-based and Original plans. The BDF-based method further reduced the doses delivered to the OARs by approximately 1-3%. The re-optimisation time was reduced by approximately 28%, but the MUs and delivery time were slightly increased. All verification tests were passed and no significant differences were found. CONCLUSION The BDF-based method for the optimisation of IMRT for cervical oesophageal cancer can achieve significantly better dose distributions with better planning efficiency at the expense of slightly more MUs.
Collapse
Affiliation(s)
- Jia-Yang Lu
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, China
| | | | - Bao-Tian Huang
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, China
| | - Li-Li Wu
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, China
| | - Wen-Jia Xie
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, China
| | - Zhi-Jian Chen
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, China
| | - De-Rui Li
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, China
| | - Liang-Xi Xie
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, China
- * E-mail:
| |
Collapse
|
6
|
Lu JY, Cheung MLM, Li M, Huang BT, Xie WJ, Xie LX. Dosimetric Evaluation of a Simple Planning Technique for Improving Intensity-Modulated Radiotherapy for Nasopharyngeal Cancer. PLoS One 2015; 10:e0129461. [PMID: 26132167 PMCID: PMC4488438 DOI: 10.1371/journal.pone.0129461] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2015] [Accepted: 05/09/2015] [Indexed: 02/05/2023] Open
Abstract
PURPOSE To evaluate the dosimetric outcomes of a simple planning technique for improving intensity-modulated radiotherapy (IMRT) for nasopharyngeal cancer (NPC). METHODS For 39 NPC cases, generally acceptable original plans were generated and were improved by the two planning techniques, respectively: (1) a basal-dose-compensation (BDC) technique, in which the treatment plans were re-optimized based on the original plans; (2) a local-dose-control (LDC) technique, in which the original plans were re-optimized with constraints for hot and cold spots. The BDC, original, and LDC plans were then compared regarding homogeneity index (HI) and conformity index (CI) of planning target volumes (PTVs), organ-at-risk (OAR) sparing and monitor units (MUs) per fraction. The whole planning times were also compared between the BDC and LDC plans. RESULTS The BDC plans had superior HIs / CIs, by 13-24% / 3-243%, respectively, over the original plans. Compared to the LDC plans, the BDC plans provided better HIs only for PTVnx (the PTV of nasopharyngeal primary tumor) by 11% and better CIs for all PTVs by 2-134%. The BDC technique spared most OARs, by 1-9%. The average MUs of the BDC, original, and LDC plans were 2149, 2068 and 2179, respectively. The average whole planning times were 48 and 69 minutes for the BDC and LDC plans, respectively. CONCLUSIONS For the IMRT of nasopharyngeal cancer, the BDC planning technique can improve target dose homogeneity, conformity and OAR sparing, with better planning efficiency.
Collapse
Affiliation(s)
- Jia-Yang Lu
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong, China
| | | | - Mei Li
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong, China
| | - Bao-Tian Huang
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong, China
| | - Wen-Jia Xie
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong, China
| | - Liang-Xi Xie
- Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong, China
- * E-mail:
| |
Collapse
|