1
|
FHRGAN: Generative adversarial networks for synthetic fetal heart rate signal generation in low-resource settings. Inf Sci (N Y) 2022. [DOI: 10.1016/j.ins.2022.01.070] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
2
|
Costa M, Xavier M, Nunes I, Henriques TS. Fetal Heart Rate Fragmentation. Front Pediatr 2021; 9:662101. [PMID: 34540762 PMCID: PMC8442730 DOI: 10.3389/fped.2021.662101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Accepted: 07/13/2021] [Indexed: 11/21/2022] Open
Abstract
Intrapartum fetal monitoring's primary goal is to avoid adverse perinatal outcomes related to hypoxia/acidosis without increasing unnecessary interventions. Recently, a set of indices were proposed as new biomarkers to analyze heart rate (HR), termed HR fragmentation (HRF). In this work, the HRF indices were applied to intrapartum fetal heart rate (FHR) traces to evaluate fetal acidemia. The fragmentation method produces four indices: PIP-Percentage of inflection points; IALS-Inverse of the average length of acceleration/deceleration segments; PSS-Percentage of short segments; PAS-Percentage of alternating segments. On the other hand, the symbolic approach studied the existence of different patterns of length four. We applied the measures to 246 selected FHR recordings sampled at 4 and 2 Hz, where 39 presented umbilical artery's pH ≤ 7.15. When applied to the 4 Hz FHR, the PIP, IASL, and PSS showed significantly higher values in the traces from acidemic fetuses. In comparison, the percentage of "words"W 1 h andW 2 s showed lower values for those traces. Furthermore, when using the 2 Hz, only IASL, W 0, andW 2 m achieved significant differences between traces from both acidemic and normal fetuses. Notwithstanding, the ideal sampling frequency is yet to be established. The fragmentation indices correlated with Sisporto variability measures, especially short-term variability. Accordingly, the fragmentation indices seem to be able to detect pathological patterns in FHR tracings. These indices have the advantage of being suitable and straightforward to apply in real-time analysis. Future studies should combine these indexes with others used successfully to detect fetal hypoxia, improving the power of discrimination in a larger dataset.
Collapse
Affiliation(s)
- Matilde Costa
- Department of Biomedical Engineering, Faculty of Engineering, Universidade do Porto, Porto, Portugal
| | - Mariana Xavier
- Department of Biomedical Engineering, Faculty of Engineering, Universidade do Porto, Porto, Portugal
| | - Inês Nunes
- Centro Materno-Infantil do Norte, Centro Hospitalar e Universitário do Porto, Porto, Portugal
- Centre for Health Technology and Services Research (CINTESIS), Faculty of Medicine University of Porto, Porto, Portugal
- ICBAS School of Medicine and Biomedical Sciences, University of Porto, Porto, Portugal
| | - Teresa S. Henriques
- Centre for Health Technology and Services Research (CINTESIS), Faculty of Medicine University of Porto, Porto, Portugal
- Department of Health Information and Decision Sciences-MEDCIDS, Faculty of Medicine, University of Porto, Porto, Portugal
| |
Collapse
|
3
|
Amer-Wåhlin I, Ugwumadu A, Yli BM, Kwee A, Timonen S, Cole V, Ayres-de-Campos D, Roth GE, Schwarz C, Ramenghi LA, Todros T, Ehlinger V, Vayssiere C. Fetal electrocardiography ST-segment analysis for intrapartum monitoring: a critical appraisal of conflicting evidence and a way forward. Am J Obstet Gynecol 2019; 221:577-601.e11. [PMID: 30980794 DOI: 10.1016/j.ajog.2019.04.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Revised: 03/31/2019] [Accepted: 04/01/2019] [Indexed: 10/27/2022]
Abstract
BACKGROUND In the past century, some areas of obstetric including intrapartum care have been slow to benefit from the dramatic advances in technology and medical care. Although fetal heart rate monitoring (cardiotocography) became available a half century ago, its interpretation often differs between institutions and countries, its diagnostic accuracy needs improvement, and a technology to help reduce the unnecessary obstetric interventions that have accompanied the cardiotocography is urgently needed. STUDY DESIGN During the second half of the 20th century, key findings in animal experiments captured the close relationship between myocardial glycogenolysis, myocardial workload, and ST changes, thus demonstrating that ST waveform analysis of the fetal electrocardiogram can provide information on oxygenation of the fetal myocardium and establishing the physiological basis for the use of electrocardiogram in intrapartum fetal surveillance. RESULTS Six randomized controlled trials, 10 meta-analyses, and more than 20 observational studies have evaluated the technology developed based on this principle. Nonetheless, despite this intensive assessment, differences in study protocols, inclusion criteria, enrollment rates, clinical guidelines, use of fetal blood sampling, and definitions of key outcome parameters, as well as inconsistencies in randomized controlled trial data handling and statistical methodology, have made this voluminous evidence difficult to interpret. Enormous resources spent on randomized controlled trials have failed to guarantee the generalizability of their results to other settings or their ability to reflect everyday clinical practice. CONCLUSION The latest meta-analysis used revised data from primary randomized controlled trials and data from the largest randomized controlled trials from the United States to demonstrate a significant reduction of metabolic acidosis rates by 36% (odds ratio, 0.64; 95% confidence interval, 0.46-0.88) and operative vaginal delivery rates by 8% (relative risk, 0.92; 95% confidence interval, 0.86-0.99), compared with cardiotocography alone.
Collapse
|
4
|
Significant reduction in umbilical artery metabolic acidosis after implementation of intrapartum ST waveform analysis of the fetal electrocardiogram. Am J Obstet Gynecol 2019; 221:63.e1-63.e13. [PMID: 30826340 DOI: 10.1016/j.ajog.2019.02.049] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 01/17/2019] [Accepted: 02/22/2019] [Indexed: 11/24/2022]
Abstract
BACKGROUND Although the evidence regarding the benefit of using ST waveform analysis of the fetal electrocardiogram is conflicting, ST waveform analysis is considered as adjunct to identify fetuses at risk for asphyxia in our center. Most randomized controlled trials and meta-analyses have not shown a significant decrease in umbilical metabolic acidosis, while some observational studies have shown a gradual decrease of this outcome over a longer period of time. Observational studies can give more insight into the effect of implementation of the ST technology in daily clinical practice. OBJECTIVE To evaluate the change in frequency of perinatal intervention and adverse neonatal outcome after the implementation of ST waveform analysis of the fetal electrocardiogram from 2000 to 2013. STUDY DESIGN This retrospective longitudinal study was conducted in a tertiary referral center. A total of 19,664 medium- and high-risk singleton pregnancies with fetuses in cephalic presentation, a gestational age of ≥36 weeks, and the intention to deliver vaginally were included. ST waveform analysis of the fetal electrocardiogram was implemented in the year 2000 and by 2010 all deliveries were monitored using this technology. Data were collected on the following perinatal outcomes: fetal blood sampling, mode of delivery, umbilical cord blood gases, Apgar scores, neonatal encephalopathy, and perinatal death. Longitudinal trend analysis was used to detect changes over time in all deliveries monitored by cardiotocography either alone or in adjunct to ST waveform analysis of the fetal electrocardiogram. Logistic regression was used to correct for possible confounders. RESULTS The umbilical artery metabolic acidosis rate declined from 2.5% (average rate of 2000 + 2001 + 2002) to 0.4% (average of 2011 + 2012 + 2013) (P < .001), which represents an 84% decrease. This decrease largely occurred between 2006 and 2008, during the Dutch randomized trial on fetal electrocardiogram ST waveform analysis. At this time, approximately 20% of deliveries were monitored using this method. Furthermore, there were significant reductions in fetal blood sampling rate (P < .001). Overall cesarean and vaginal instrumental deliveries decreased significantly (P < .001), but not for fetal distress. There were no changes in the Apgar scores. The incidence of neonatal encephalopathy was significantly lower in the second part of the study (odds ratio 0.39, 95% confidence interval 0.17-0.89). CONCLUSION There was an 84% decrease in the incidence of umbilical artery metabolic acidosis in all deliveries between 2000 and 2013. The neonatal encephalopathy rate, fetal blood sampling rate, and the total number of cesarean and vaginal instrumental deliveries also decreased.
Collapse
|
5
|
Lopes-Pereira J, Costa A, Ayres-De-Campos D, Costa-Santos C, Amaral J, Bernardes J. Computerized analysis of cardiotocograms and ST signals is associated with significant reductions in hypoxic-ischemic encephalopathy and cesarean delivery: an observational study in 38,466 deliveries. Am J Obstet Gynecol 2019; 220:269.e1-269.e8. [PMID: 30594567 DOI: 10.1016/j.ajog.2018.12.037] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2018] [Revised: 11/29/2018] [Accepted: 12/20/2018] [Indexed: 11/28/2022]
Abstract
BACKGROUND Intrapartum cardiotocography is widely used in high-resource countries and remains at the center of fetal monitoring and the decision to intervene, but there is ample evidence of poor reliability in visual interpretation as well as limited accuracy in identifying fetal hypoxia. Combined monitoring of intrapartum cardiotocography and ST segment signals was developed to increase specificity, but analysis relies heavily on intrapartum cardiotocography interpretation and is therefore also affected by the previously referred problems. Computerized analysis was developed to overcome these limitations, aiding in the quantification of parameters that are difficult to evaluate visually, such as variability, integrating the complex guidelines of combined intrapartum cardiotocography and ST analysis, and using visual and sound alerts to prompt health care professionals to reevaluate features associated with fetal hypoxia. OBJECTIVE The objective of the study was to evaluate the effect of introducing a central fetal monitoring system with computerized analysis of intrapartum cardiotocography and ST signals into the labor ward of a tertiary care university hospital in which all women are continuously monitored with intrapartum cardiotocography. The incidence of adverse perinatal outcomes and intervention rates was evaluated over time. STUDY DESIGN In this retrospective cohort study, yearly rates of hypoxic-ischemic encephalopathy, instrumental vaginal delivery, overall cesarean delivery, and urgent cesarean delivery were obtained from the hospital's clinical databases. The rates occurring in the period from January 2001 to December 2003, before the introduction of the central monitoring system with computerized analysis of intrapartum cardiotocography and ST signals (Omniview-SisPorto), were compared with those occurring from January 2004 to December 2014, after the introduction of the system. All rates were calculated with 95% confidence intervals. RESULTS A total of 38,466 deliveries occurred during this period. After introduction of the system, there was a significant decrease in the number of hypoxic-ischemic encephalopathy cases per 1000 births (5.3%, 95% confidence interval [4.0-7.0] vs 2.2%, 95% confidence interval [1.7-2.8]; relative risk, 0.42, 95% confidence interval [0.29-0.61]), overall cesarean delivery rates (29.9%, 95% confidence interval [28.9-30.8] vs 28.3%, 95% confidence interval [27.8-28.8]; relative risk, 0.96, 95% confidence interval [0.92-0.99]), and urgent cesarean deliveries (21.6%, 95% confidence interval [20.7-22.4] vs 19.2%, 95% confidence interval [18.8-19.7]; relative risk, 0.91, 95% confidence interval [0.87-0.95]). The instrumental vaginal delivery rate increased (19.5%, 95% confidence interval [18.7-20.3] vs 21.4%, 95% confidence interval [21.0-21.9; relative risk, 1.07, 95% confidence interval 1.02-1.13]. CONCLUSION Introduction of computerized analysis of intrapartum cardiotocography and ST signals in a tertiary care hospital was associated with a significant reduction in the incidence of hypoxic-ischemic encephalopathy and a modest reduction in cesarean deliveries.
Collapse
Affiliation(s)
- Joana Lopes-Pereira
- Department of Obstetrics and Gynecology, University of Porto School of Medicine, and Centro Hospitalar, S. João, Portugal.
| | - Antónia Costa
- Department of Obstetrics and Gynecology, University of Porto School of Medicine, and Centro Hospitalar, S. João, Portugal; Institute of Biomedical Engineering, University of Porto School of Medicine, Porto, Portugal.
| | - Diogo Ayres-De-Campos
- Institute of Biomedical Engineering, University of Porto School of Medicine, Porto, Portugal; Department of Health Information and Decision Sciences and Center for Research in Health Technology and Services, University of Porto School of Medicine, Porto, Portugal; Department of Obstetrics, Gynecology, and Reproductive Medicine, Santa Maria Hospital, University of Lisbon School of Medicine, Lisbon, Portugal
| | - Cristina Costa-Santos
- Department of Health Information and Decision Sciences and Center for Research in Health Technology and Services, University of Porto School of Medicine, Porto, Portugal
| | - Joana Amaral
- Department of Obstetrics and Gynecology, University of Porto School of Medicine, and Centro Hospitalar, S. João, Portugal
| | - João Bernardes
- Department of Obstetrics and Gynecology, University of Porto School of Medicine, and Centro Hospitalar, S. João, Portugal; Institute of Biomedical Engineering, University of Porto School of Medicine, Porto, Portugal
| |
Collapse
|
6
|
Andriessen P, Zwanenburg A, van Laar JOEH, Vullings R, Hermans BJM, Niemarkt HJ, Jellema RK, Ophelders DRMG, Wolfs TGAM, Kramer BW, Delhaas T. ST waveform analysis for monitoring hypoxic distress in fetal sheep after prolonged umbilical cord occlusion. PLoS One 2018; 13:e0195978. [PMID: 29659625 PMCID: PMC5901956 DOI: 10.1371/journal.pone.0195978] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2017] [Accepted: 04/03/2018] [Indexed: 11/18/2022] Open
Abstract
INTRODUCTION The inconclusive clinical results for ST-waveform analysis (STAN) in detecting fetal hypoxemia may be caused by the signal processing of the STAN-device itself. We assessed the performance of a clinical STAN device in signal processing and in detecting hypoxemia in a fetal sheep model exposed to prolonged umbilical cord occlusion (UCO). METHODS Eight fetal lambs were exposed to 25 minutes of UCO. ECG recordings were analyzed during a baseline period and during UCO. STAN-event rates and timing of episodic T/QRS rise, baseline T/QRS rise and the occurrence of biphasic ST-waveforms, as well as signal loss, were assessed. RESULTS During baseline conditions of normoxemia, a median of 40 (IQR, 25-70) STAN-events per minute were detected, compared to 10 (IQR, 2-22) during UCO. During UCO STAN-events were detected in five subjects within 10 minutes and in six subjects after 18 minutes, respectively. Two subjects did not generate any STAN-event during UCO. Biphasic ST event rate was reduced during UCO (median 0, IQR 0-5), compared to baseline (median 32, IQR, 6-55). ST-waveforms could not be assessed in 62% of the recording time during UCO, despite a good quality of the ECG signal. CONCLUSIONS The STAN device showed limitations in detecting hypoxemia in fetal sheep after prolonged UCO. The STAN device produced high false positive event rates during baseline and did not detect T/QRS changes adequately after prolonged fetal hypoxemia. During 14% of baseline and 62% of the UCO period, the STAN-device could not process the ECG signal, despite its good quality. Resolving these issues may improve the clinical performance of the STAN device.
Collapse
Affiliation(s)
- Peter Andriessen
- Department of Pediatrics, Máxima Medical Centre, Veldhoven, the Netherlands
- Department of Pediatrics, Maastricht University Medical Centre, Maastricht, the Netherlands
| | - Alex Zwanenburg
- Department of Biomedical Engineering, Maastricht University, Maastricht, the Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, the Netherlands
- School for Mental Health and Neuroscience, Maastricht University, Maastricht, the Netherlands
| | | | - Rik Vullings
- Signal Processing Systems group, Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Ben J. M. Hermans
- Department of Biomedical Engineering, Maastricht University, Maastricht, the Netherlands
| | | | - Reint K. Jellema
- Department of Pediatrics, Máxima Medical Centre, Veldhoven, the Netherlands
- Department of Pediatrics, Maastricht University Medical Centre, Maastricht, the Netherlands
| | - Daan R. M. G. Ophelders
- Department of Pediatrics, Maastricht University Medical Centre, Maastricht, the Netherlands
- School for Mental Health and Neuroscience, Maastricht University, Maastricht, the Netherlands
| | - Tim G. A. M. Wolfs
- Department of Pediatrics, Maastricht University Medical Centre, Maastricht, the Netherlands
- Department of Biomedical Engineering, Maastricht University, Maastricht, the Netherlands
- School for Mental Health and Neuroscience, Maastricht University, Maastricht, the Netherlands
| | - Boris W. Kramer
- Department of Pediatrics, Maastricht University Medical Centre, Maastricht, the Netherlands
- School for Mental Health and Neuroscience, Maastricht University, Maastricht, the Netherlands
| | - Tammo Delhaas
- Department of Biomedical Engineering, Maastricht University, Maastricht, the Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, the Netherlands
| |
Collapse
|
7
|
Central Fetal Monitoring With and Without Computer Analysis: A Randomized Controlled Trial. Obstet Gynecol 2017; 129:83-90. [PMID: 27926647 DOI: 10.1097/aog.0000000000001799] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To evaluate whether intrapartum fetal monitoring with computer analysis and real-time alerts decreases the rate of newborn metabolic acidosis or obstetric intervention when compared with visual analysis. METHODS A randomized clinical trial carried out in five hospitals in the United Kingdom evaluated women with singleton, vertex fetuses of 36 weeks of gestation or greater during labor. Continuous central fetal monitoring by computer analysis and online alerts (experimental arm) was compared with visual analysis (control arm). Fetal blood sampling and electrocardiographic ST waveform analysis were available in both arms. The primary outcome was incidence of newborn metabolic acidosis (pH less than 7.05 and base deficit greater than 12 mmol/L). Prespecified secondary outcomes included operative delivery, use of fetal blood sampling, low 5-minute Apgar score, neonatal intensive care unit admission, hypoxic-ischemic encephalopathy, and perinatal death. A sample size of 3,660 per group (N=7,320) was planned to be able to detect a reduction in the rate of metabolic acidosis from 2.8% to 1.8% (two-tailed α of 0.05 with 80% power). RESULTS From August 2011 through July 2014, 32,306 women were assessed for eligibility and 7,730 were randomized: 3,961 to computer analysis and online alerts, and 3,769 to visual analysis. Baseline characteristics were similar in both groups. Metabolic acidosis occurred in 16 participants (0.40%) in the experimental arm and 22 participants (0.58%) in the control arm (relative risk 0.69 [0.36-1.31]). No statistically significant differences were found in the incidence of secondary outcomes. CONCLUSION Compared with visual analysis, computer analysis of fetal monitoring signals with real-time alerts did not significantly reduce the rate of metabolic acidosis or obstetric intervention. A lower-than-expected rate of newborn metabolic acidosis was observed in both arms of the trial. CLINICAL TRIAL REGISTRATION ISRCTN Registry, http://www.isrctn.com, ISRCTN42314164.
Collapse
|
8
|
Bloom SL, Belfort M, Saade G. What we have learned about intrapartum fetal monitoring trials in the MFMU Network. Semin Perinatol 2016; 40:307-17. [PMID: 27140936 PMCID: PMC4983203 DOI: 10.1053/j.semperi.2016.03.008] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The vast majority of pregnant women are subjected to electronic fetal heart monitoring during labor. There is limited evidence to support its benefit compared with intermittent auscultation. In addition, there is significant variability in interpretation and its false-positive rate is high. The latter may have contributed to the rise in operative deliveries. In order to address the critical need for better approaches to intrapartum monitoring, the MFMU Network has completed two large multisite randomized trials, one to evaluate fetal pulse oximetry and the other to evaluate fetal ECG ST segment analysis (STAN). Both of these technologies had been approved for clinical use in the United States based on prior smaller trials. These technologies were evaluated in laboring women near term and their primary outcomes were overall cesarean delivery for the oximetry trial and a composite adverse neonatal outcome for STAN. Both the trials failed to show a benefit of the technology, neither in the rates of operative deliveries nor in the rates of adverse neonatal outcomes. The experience with these trials, summarized in this report, highlights the need for rigorous evidence before introduction of new technology into clinical practice and provides a blueprint for future trials to address the need for better intrapartum monitoring approaches.
Collapse
Affiliation(s)
- Steven L. Bloom
- Department of Obstetrics and Gynecology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390
| | - Michael Belfort
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Texas Children’s Hospital Pavilion for Women, 6651 Main Street, Houston, TX 77030
| | - George Saade
- Department of Obstetrics and Gynecology, The University of Texas Medical Branch, 301 University Boulevard, Galveston, TX 77555
| | | |
Collapse
|
9
|
Andersen MM, Thisted DLA, Amer-Wåhlin I, Krebs L. Can Intrapartum Cardiotocography Predict Uterine Rupture among Women with Prior Caesarean Delivery?: A Population Based Case-Control Study. PLoS One 2016; 11:e0146347. [PMID: 26872018 PMCID: PMC4752316 DOI: 10.1371/journal.pone.0146347] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2015] [Accepted: 12/16/2015] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVE To compare cardiotocographic abnormalities recorded during labour in women with prior caesarean delivery (CD) and complete uterine rupture with those recorded in controls with prior CD without uterine rupture. STUDY DESIGN Women with complete uterine rupture during labour between 1997 and 2008 were identified in the Danish Medical Birth Registry (n = 181). Cases were validated by review of medical records and 53 cases with prior CD, trial of labour, available cardiotocogram (CTG) and complete uterine rupture were included and compared with 43 controls with prior CD, trial of labour and available CTG. The CTG tracings were assessed by 19 independent experts divided into groups of three different experts for each tracing. The assessors were blinded to group, outcome and clinical data. They analyzed occurrence of defined abnormalities and classified the traces as normal, suspicious, pathological or pre-terminal according to international guidelines (FIGO). RESULTS A pathological CTG during the first stage of labour was present in 77% of cases and in 53% of the controls (OR 2.58 [CI: 0.96-6.94] P = 0.066). Fetal tachycardia was more frequent in cases with uterine rupture (OR 2.50 [CI: 1.0-6.26] P = 0.053). Significantly more cases showed more than 10 severe variable decelerations compared with controls (OR 22 [CI: 1.54-314.2] P = 0.022). Uterine tachysystole was not correlated with the presence of uterine rupture. CONCLUSION A pathological cardiotocogram should lead to particular attention on threatening uterine rupture but cannot be considered a strong predictor as it is common in all women with trial of labour after caesarean delivery.
Collapse
Affiliation(s)
- Malene M. Andersen
- Dept. of Obstetrics and Gynaecology, University of Copenhagen, Holbaek Hospital, Holbaek, Denmark
| | - Dorthe L. A. Thisted
- Dept. of Obstetrics and Gynaecology, University of Copenhagen, Holbaek Hospital, Holbaek, Denmark
- University of Copenhagen, Hvidovre Hospital, Dept. of Obstetric and Gynecology, Hvidovre, Denmark
| | - Isis Amer-Wåhlin
- Dept. of Women and Child Health, Karolinska Institute, Stockholm, Sweden
| | - Lone Krebs
- Dept. of Obstetrics and Gynaecology, University of Copenhagen, Holbaek Hospital, Holbaek, Denmark
| | | |
Collapse
|
10
|
Amer-Wahlin I, Kwee A. Combined cardiotocographic and ST event analysis: A review. Best Pract Res Clin Obstet Gynaecol 2016. [DOI: 10.1016/j.bpobgyn.2015.05.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
11
|
Bhide A, Chandraharan E, Acharya G. Fetal monitoring in labor: Implications of evidence generated by new systematic review. Acta Obstet Gynecol Scand 2015; 95:5-8. [DOI: 10.1111/aogs.12830] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Amar Bhide
- Department of Obstetrics and Gynecology; St. George's Hospital; London UK
| | - Edwin Chandraharan
- Department of Obstetrics and Gynecology; St. George's Hospital; London UK
| | - Ganesh Acharya
- Department of Clinical Medicine; UiT- The Arctic University of Norway; Tromsø Norway
- Department of Obstetrics and Gynecology; University Hospital of Northern Norway; Tromsø Norway
| |
Collapse
|
12
|
Hruban L, Spilka J, Chudáček V, Janků P, Huptych M, Burša M, Hudec A, Kacerovský M, Koucký M, Procházka M, Korečko V, Seget'a J, Šimetka O, Měchurová A, Lhotská L. Agreement on intrapartum cardiotocogram recordings between expert obstetricians. J Eval Clin Pract 2015; 21:694-702. [PMID: 26011725 DOI: 10.1111/jep.12368] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 03/10/2015] [Indexed: 12/26/2022]
Abstract
RATIONALE, AIMS AND OBJECTIVES To evaluate obstetricians' inter- and intra-observer agreement on intrapartum cardiotocogram (CTG) recordings and to examine obstetricians' evaluations with respect to umbilical artery pH and base deficit. METHODS Nine experienced obstetricians annotated 634 intrapartum CTG recordings. The evaluation of each recording was divided into four steps: evaluation of two 30-minute windows in the first stage of labour, evaluation of one window in the second stage of labour and labour outcome prediction. The complete set of evaluations used for this experiment is available online. The inter- and intra-observer agreement was evaluated using proportion of agreement and kappa coefficient. Clinicians' sensitivity and specificity was computed with respect to umbilical artery pH, base deficit and to Apgar score at the fifth minute. RESULTS The overall proportion of agreement between clinicians reached 48% with 95% confidence intervals (CI) (CI: 47-50). Regarding the different classes, proportion of agreement ranged from 57% (CI: 54-60) for normal to 41% (CI: 36-46) for pathological class. The sensitivity of clinicians' majority vote to objective outcome was 39% (CI: 16-63) for the umbilical artery base deficit and 27% (CI: 16-42) for pH. The specificity was 89% (CI: 86-92) for both types of objective outcome. CONCLUSIONS The reported inter-/intra-observer variability is large and this holds irrespective of clinicians' experience or work place. The results support the need of modernized guidelines for CTG evaluation and/or objectivization and repeatability by introduction of a computerized approach that could standardize the process of CTG evaluation within the delivery ward.
Collapse
Affiliation(s)
- Lukáš Hruban
- Department of Gynecology and Obstetrics, Masaryk University Hospital, Brno, Czech Republic
| | - Jiří Spilka
- Department of Cybernetics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic.,Czech Institute of Informatics, Robotics and Cybernetics, Czech Technical University in Prague, Prague, Czech Republic
| | - Václav Chudáček
- Department of Cybernetics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic.,Czech Institute of Informatics, Robotics and Cybernetics, Czech Technical University in Prague, Prague, Czech Republic
| | - Petr Janků
- Department of Gynecology and Obstetrics, Masaryk University Hospital, Brno, Czech Republic
| | - Michal Huptych
- Department of Cybernetics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic
| | - Miroslav Burša
- Department of Cybernetics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic
| | - Adam Hudec
- Department of Gynecology and Obstetrics, University Hospital in Plzeň, Plzeň, Czech Republic
| | - Marian Kacerovský
- Department of Gynecology and Obstetrics, University Hospital in Hradec Králové, Hradec Králové, Czech Republic
| | - Michal Koucký
- Department of Gynecology and Obstetrics, University Hospital in Prague, Prague, Czech Republic
| | - Martin Procházka
- Department of Gynecology and Obstetrics, University Hospital in Olomouc, Olomouc, Czech Republic
| | - Vladimír Korečko
- Department of Gynecology and Obstetrics, University Hospital in Plzeň, Plzeň, Czech Republic
| | - Jan Seget'a
- Department of Gynecology and Obstetrics, University Hospital Ostrava, Ostrava, Czech Republic
| | - Ondřej Šimetka
- Department of Gynecology and Obstetrics, University Hospital Ostrava, Ostrava, Czech Republic.,Department of Surgical Studies, Ostrava University, Ostrava, Czech Republic
| | - Alena Měchurová
- Department for Mother and Child Care, Prague Podolí, Prague, Czech Republic
| | - Lenka Lhotská
- Department of Cybernetics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic
| |
Collapse
|
13
|
Prior T, Kumar S. Expert review--identification of intra-partum fetal compromise. Eur J Obstet Gynecol Reprod Biol 2015; 190:1-6. [PMID: 25917435 DOI: 10.1016/j.ejogrb.2015.04.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Revised: 01/31/2015] [Accepted: 04/07/2015] [Indexed: 09/30/2022]
Abstract
Whilst most cases of cerebral palsy occur as a consequence of an ante-natal insult, a significant proportion, particularly in the term fetus, are attributable to intra-partum hypoxia. Intra-partum monitoring using continuous fetal heart rate assessment has led to an increased incidence of operative delivery without a concurrent reduction in the incidence of cerebral palsy. Despite this, birth asphyxia remains the strongest and most consistent risk factor for cerebral palsy in term infants. This review evaluates current intra-partum monitoring techniques as well as alternative approaches aimed at better identification of the fetus at risk of compromise in labour.
Collapse
Affiliation(s)
- Tomas Prior
- Centre for Fetal Care, Queen Charlotte's and Chelsea Hospital, Du Cane Road, London W12 0HS, UK; Institute for Reproductive and Developmental Biology, Imperial College London, London W12 0HS, UK
| | - Sailesh Kumar
- Centre for Fetal Care, Queen Charlotte's and Chelsea Hospital, Du Cane Road, London W12 0HS, UK; Institute for Reproductive and Developmental Biology, Imperial College London, London W12 0HS, UK; Mater Research Institute/University of Queensland, Aubigny Place, Raymond Terrace, South Brisbane, QLD 4101, Australia.
| |
Collapse
|
14
|
Steer PJ, Hvidman LE. Scientific and clinical evidence for the use of fetal ECG ST segment analysis (STAN). Acta Obstet Gynecol Scand 2014; 93:533-8. [PMID: 24597897 DOI: 10.1111/aogs.12369] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2014] [Accepted: 02/27/2014] [Indexed: 11/29/2022]
Abstract
Fetal electrocardiogram waveform analysis has been studied for many decades, but it is only in the last 20 years that computerization has made real-time analysis practical for clinical use. Changes in the ST segment have been shown to correlate with fetal condition, in particular with acid-base status. Meta-analysis of randomized trials (five in total, four using the computerized system) has shown that use of computerized ST segment analysis (STAN) reduces the need for fetal blood sampling by about 40%. However, although there are trends to lower rates of low Apgar scores and acidosis, the differences are not statistically significant. There is no effect on cesarean section rates. Disadvantages include the need for amniotic membranes to be ruptured so that a fetal scalp electrode can be applied, and the need for STAN values to be interpreted in conjunction with detailed fetal heart rate pattern analysis.
Collapse
Affiliation(s)
- Philip J Steer
- Academic Department of Obstetrics and Gynecology, Division of Cancer, Chelsea and Westminster Hospital, London, UK
| | | |
Collapse
|
15
|
SALMELIN ANETTE, WIKLUND INGELA, BOTTINGA ROGER, BRORSSON BENGT, EKMAN-ORDEBERG GUNVOR, GRIMFORS EVAENEROTH, HANSON ULF, BLOM MAY, PERSSON ELISABETH. Fetal monitoring with computerized ST analysis during labor: a systematic review and meta-analysis. Acta Obstet Gynecol Scand 2012; 92:28-39. [DOI: 10.1111/aogs.12009] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
16
|
|
17
|
WESTERHUIS MICHELLEE, PORATH MARTINAM, BECKER JEROENH, VAN DEN AKKER ELINES, VAN BEEK ERIK, VAN DESSEL HENDRIKUSJ, DROGTROP ADDYP, VAN GEIJN HERMANP, GRAZIOSI GIUSEPPIC, GROENENDAAL FLORIS, VAN LITH JANM, MOL BENWILLEMJ, MOONS KARELG, NIJHUIS JANG, OEI SWANG, OOSTERBAAN HERMANP, RIJNDERS ROBBERTJ, SCHUITEMAKER NICOW, WIJNBERGER LIAD, WILLEKES CHRISTINE, WOUTERS MAURICEG, VISSER GERARDH, KWEE ANNEKE. Identification of cases with adverse neonatal outcome monitored by cardiotocography versus ST analysis: secondary analysis of a randomized trial. Acta Obstet Gynecol Scand 2012; 91:830-7. [DOI: 10.1111/j.1600-0412.2012.01431.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
18
|
Human factors affecting the interpretation of fetal heart rate tracings: an update. Curr Opin Obstet Gynecol 2012; 24:84-8. [PMID: 22249147 DOI: 10.1097/gco.0b013e3283505b3c] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
PURPOSE OF REVIEW Human factors can have an important impact on cardiotocography (CTG) interpretation and management decisions, and therefore may directly affect obstetrical outcomes. RECENT FINDINGS It has been well demonstrated that there is wide observer disagreement over CTG interpretation, particularly in the evaluation of variability, decelerations, and overall tracing classification. The reasons behind this are still incompletely understood, but poor reproducibility can have a profound impact on the technology's accuracy and on its efficacy. Some scientific societies have recently revised their guidelines for CTG interpretation, but no up-to-date universally accepted recommendation exists. In spite of some approximation between the major guideline sets, important differences still exist between them, and they remain complex and prone to memory decay. Regular training in CTG interpretation appears to result in increased knowledge, better observer agreement, and improved quality of care. Computer analysis has also been developed, but remains heavily dependent on staff to confirm interpretation and to decide clinical management. SUMMARY An international consensus, comprising simpler and more objective interpretation guidelines, together with regular staff training, and improved decision support systems seem to be the way forward for this technology.
Collapse
|
19
|
Massoud M, Bloc F, Gaucherand P, Doret M. How deviations from STAN guidelines contribute to operative delivery for suspected fetal distress. Eur J Obstet Gynecol Reprod Biol 2012; 162:45-9. [DOI: 10.1016/j.ejogrb.2012.02.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2011] [Revised: 01/18/2012] [Accepted: 02/10/2012] [Indexed: 10/28/2022]
|
20
|
Berglund S. "Every case of asphyxia can be used as a learning example". Conclusions from an analysis of substandard obstetrical care. J Perinat Med 2011; 40:9-18. [PMID: 22080723 DOI: 10.1515/jpm.2011.108] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2011] [Accepted: 08/17/2011] [Indexed: 11/15/2022]
Abstract
AIM To propose suggestions for improvements in care based on conclusions from studies on low Apgar scores and substandard care during labor. SETTING AND PATIENTS Studies on infants with low Apgar scores in a general obstetric population 2004-2006 and claims for financial compensation on the behalf of infants, based on the suspicion that substandard care in conjunction with childbirth has caused severe asphyxia or neonatal death in Sweden 1990-2005. RESULTS The most common flaws were related to insufficient fetal surveillance, defective interpretation of cardiotocography (CTG) tracings, not acting in a timely fashion on abnormal CTG, and the incautious use of oxytocin. Besides, in half of the infants a suboptimal mode of delivery added further trauma to the already asphyxiated infant. Additionally, resuscitation was unsatisfactory in many of these infants. The most critical flaw was defective compliance with the guidelines concerning ventilation and the early paging of skilled personnel in cases of imminent asphyxia or known complications during labor. In many case reports, the documentation of the neonatal resuscitation was insufficient to enable accurate and reliable evaluation. CONCLUSIONS Examples of proposed improvements in care during labor are the introduction of a permanent educational atmosphere with aside time for daily educational rounds and discussion, cooperation around the use of standardized terminology in CTG interpretation, the cautious use of oxytocin, and the routine paging of a pediatrician before birth in cases of complicated delivery or imminent asphyxia. The proposed interventions need to be evaluated in clinical trials in the future.
Collapse
Affiliation(s)
- Sophie Berglund
- Department of Clinical Sciences, Karolinska Institutet, Danderyd Hospital, Stockholm, Sweden.
| |
Collapse
|
21
|
Becker JH, Westerhuis MEMH, Sterrenburg K, van den Akker ESA, van Beek E, Bolte AC, van Dessel TJHM, Drogtrop AP, van Geijn HP, Graziosi GCM, van Lith JMM, Mol BWJ, Moons KGM, Nijhuis JG, Oei SG, Oosterbaan HP, Porath MM, Rijnders RJP, Schuitemaker NWE, Wijnberger LDE, Willekes C, Visser GHA, Kwee A. Fetal blood sampling in addition to intrapartum ST-analysis of the fetal electrocardiogram: evaluation of the recommendations in the Dutch STAN® trial. BJOG 2011; 118:1239-46. [DOI: 10.1111/j.1471-0528.2011.03027.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
22
|
Use of peripartum ST analysis of fetal electrocardiogram without blood sampling: a large prospective cohort study. Eur J Obstet Gynecol Reprod Biol 2011; 156:35-40. [DOI: 10.1016/j.ejogrb.2010.12.042] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2010] [Revised: 11/22/2010] [Accepted: 12/29/2010] [Indexed: 01/12/2023]
|
23
|
Abstract
Since its introduction more than 40 years ago, electronic fetal monitoring has become widely used for intrapartum surveillance to determine fetal wellbeing in labor. Although fetal hypoxia and acidosis are reflected in changes in fetal heart rate, there is no evidence that cardiotocography has been effective in reducing neonatal morbidity related to fetal distress occurring during labor. Indeed the specificity of this tool is poor and in many instances the incorporation of electronic fetal monitoring into intrapartum care has merely led to an increase in medical intervention rather than an improvement in neonatal outcome. Fetal electrocardiography (ECG) analysis provides an additional method for assessing the response of the fetus to hypoxia and in particular to the development of metabolic acidosis. ST changes in the fetal ECG can be quantified with computational analysis, reducing subjective interpretation that has been problematic with traditional electronic fetal monitoring. Formal algorithms indicating appropriate points for intervention in labor have been designed. The fetal ECG has been shown to be a useful adjunct to traditional electronic fetal monitoring in several randomized controlled trials with evidence of reduced rates of neonatal encephalopathy and reduced rates of obstetric intervention.
Collapse
Affiliation(s)
- I Amer-Wåhlin
- Department of Women and Child Health, ALB Q2:7, Karolinska Institute, 171 76 Solna, Stockholm, Sweden.
| | | |
Collapse
|
24
|
Ayres-de-Campos D, Ugwumadu A, Banfield P, Lynch P, Amin P, Horwell D, Costa A, Santos C, Bernardes J, Rosen K. A randomised clinical trial of intrapartum fetal monitoring with computer analysis and alerts versus previously available monitoring. BMC Pregnancy Childbirth 2010; 10:71. [PMID: 21029466 PMCID: PMC2987886 DOI: 10.1186/1471-2393-10-71] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2009] [Accepted: 10/28/2010] [Indexed: 11/17/2022] Open
Abstract
Background Intrapartum fetal hypoxia remains an important cause of death and permanent handicap and in a significant proportion of cases there is evidence of suboptimal care related to fetal surveillance. Cardiotocographic (CTG) monitoring remains the basis of intrapartum surveillance, but its interpretation by healthcare professionals lacks reproducibility and the technology has not been shown to improve clinically important outcomes. The addition of fetal electrocardiogram analysis has increased the potential to avoid adverse outcomes, but CTG interpretation remains its main weakness. A program for computerised analysis of intrapartum fetal signals, incorporating real-time alerts for healthcare professionals, has recently been developed. There is a need to determine whether this technology can result in better perinatal outcomes. Methods/design This is a multicentre randomised clinical trial. Inclusion criteria are: women aged ≥ 16 years, able to provide written informed consent, singleton pregnancies ≥ 36 weeks, cephalic presentation, no known major fetal malformations, in labour but excluding active second stage, planned for continuous CTG monitoring, and no known contra-indication for vaginal delivery. Eligible women will be randomised using a computer-generated randomisation sequence to one of the two arms: continuous computer analysis of fetal monitoring signals with real-time alerts (intervention arm) or continuous CTG monitoring as previously performed (control arm). Electrocardiographic monitoring and fetal scalp blood sampling will be available in both arms. The primary outcome measure is the incidence of fetal metabolic acidosis (umbilical artery pH < 7.05, BDecf > 12 mmol/L). Secondary outcome measures are: caesarean section and instrumental vaginal delivery rates, use of fetal blood sampling, 5-minute Apgar score < 7, neonatal intensive care unit admission, moderate and severe neonatal encephalopathy with a marker of hypoxia, perinatal death, rate of internal monitoring, tracing quality, and signal loss. Analysis will follow an intention to treat principle. Incidences of primary and secondary outcomes will be compared between groups. Assuming a reduction in metabolic acidosis from 2.8% to 1.8%, using a two-sided test with alpha = 0.05, power = 0.80, and 10% loss to follow-up, 8133 women need to be randomised. Discussion This study will provide evidence of the impact of intrapartum monitoring with computer analysis and real-time alerts on the incidence of adverse perinatal outcomes, intrapartum interventions and signal quality. (Current controlled trials ISRCTN42314164)
Collapse
Affiliation(s)
- Diogo Ayres-de-Campos
- Departmento de Ginecologia e Obstetrícia, Faculdade de Medicina do Porto, Alameda Hernani Monteiro 4200-319 Porto, Portugal.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Ragupathy K, Ismail F, Nicoll AE. The use of STAN monitoring in the labour ward. J OBSTET GYNAECOL 2010; 30:465-9. [DOI: 10.3109/01443615.2010.482218] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
26
|
Cleal JK, Thomas M, Hanson MA, Paterson-Brown S, Gardiner HM, Green LR. Noninvasive fetal electrocardiography following intermittent umbilical cord occlusion in the preterm ovine fetus. BJOG 2010; 117:438-44. [PMID: 20374581 DOI: 10.1111/j.1471-0528.2009.02471.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
OBJECTIVE To investigate whether a noninvasive fetal electrocardiography (fECG) system can identify cardiovascular responses to fetal hypoxaemia and validate the results using standard invasive fECG monitoring techniques. DESIGN Prospective cohort study. SETTING Biological research facilities at The University of Southampton. POPULATION OR SAMPLE Late gestation ovine fetuses; n = 5. METHODS Five fetal lambs underwent implantation of vascular catheters, umbilical cord occluder and invasive ECG chest electrodes under general anaesthesia (3% halothane/O(2)) at 119 days of gestation (term approximately 147 days of gestation). After 5 days of recovery blood pressure, blood gases, glucose and pH were monitored. At 124 and 125 days of gestation following a 10-minute baseline period a 90-second cord occlusion was applied. Noninvasive fetal ECG was recorded from maternal transabdominal electrodes using advanced signal-processing techniques, concurrently with invasive fECG recordings. MAIN OUTCOME MEASURES Comparison of T:QRS ratios of the ECG waveform from noninvasive and invasive fECG monitoring systems. RESULTS Our fECG monitoring system is able to demonstrate changes in waveforms during periods of hypoxaemia similar to those obtained invasively, which could indicate fetal distress. CONCLUSIONS These findings may indicate a future use for noninvasive electrocardiography during human fetal monitoring both before and during labour in term and preterm pregnancies.
Collapse
Affiliation(s)
- J K Cleal
- Institute of Developmental Sciences, University of Southampton, UK.
| | | | | | | | | | | |
Collapse
|
27
|
Kumar S, Paterson-Brown S. Obstetric aspects of hypoxic ischemic encephalopathy. Early Hum Dev 2010; 86:339-44. [PMID: 20638984 DOI: 10.1016/j.earlhumdev.2010.05.009] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2010] [Accepted: 05/07/2010] [Indexed: 11/25/2022]
Abstract
Hypoxic ischemic encephalopathy (HIE) describes neonatal encephalopathy that is caused by intrapartum asphyxia and it can result in the long term sequelae of cerebral palsy which is a major cause of disability. The incidence of cerebral palsy has not changed over the last few decades and the challenge to obstetricians remains how best to recognise those babies at risk of this intrapartum insult both before and during labour. Many associations and risk factors are unavoidable or unrecognisable, and others are fairly common and associated with poor predictive value. Intrapartum fetal heart monitoring remains the main focus of attention but how this is best achieved is still the subject of research. Computerised decision support systems built into fetal heart rate monitoring and non-invasive fetal ECG signal pick-up are currently being explored.
Collapse
Affiliation(s)
- Sailesh Kumar
- Queen Charlotte's and Chelsea Hospital, Imperial College London, Du Cane Road, London W12 0HS, United Kingdom.
| | | |
Collapse
|
28
|
|
29
|
Abstract
The technology of intrapartum surveillance made rapid strides from the 1960s through the 1980s but then stagnated as increasing resort to caesarean section was made rather than improving measures of fetal condition and labour progress. However, despite caesarean section rates commonly over 30%, medicolegally expensive mistakes continue to be made because it is difficult to teach clinicians to make reliable use of existing technology. It may be that as with aircraft navigation, the safest solution is to replace human judgement with the obstetric equivalent of automatic pilots.
Collapse
Affiliation(s)
- Philip J Steer
- Academic Department of Obstetrics and Gynaecology, Imperial College Faculty of Medicine, Chelsea and Westminster Hospital, London, UK.
| |
Collapse
|
30
|
Costa A, Ayres-de-Campos D, Costa F, Santos C, Bernardes J. Prediction of neonatal acidemia by computer analysis of fetal heart rate and ST event signals. Am J Obstet Gynecol 2009; 201:464.e1-6. [PMID: 19539895 DOI: 10.1016/j.ajog.2009.04.033] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2008] [Revised: 01/07/2009] [Accepted: 04/20/2009] [Indexed: 11/24/2022]
Abstract
OBJECTIVE The objective of the study was to evaluate the accuracy of computer analysis of fetal heart rate (FHR) and ST event signals in prediction of neonatal acidemia. STUDY DESIGN One hundred forty-eight FHR tracings were evaluated to identify red alerts provided by the system, based on automated analysis of FHR and ST event signals, and compared with the occurrence of umbilical artery acidemia (pH < or =7.05). RESULTS The presence of red alerts obtained sensitivity of 1.00 (95% confidence interval [CI], 0.56-1.00), specificity of 0.94 (95% CI, 0.89-0.97), positive predictive value (PPV) of 0.47 (95% CI, 0.22-0.72), negative predictive value (NPV) of 1 (95% CI, 0.96-1.00), positive likelihood ratio (PLR) of 17.6 (95% CI, 9.0-34.5), and negative likelihood ratio (NLR) of 0. When limiting analysis to red alerts that did not include ST data, sensitivity was 0.57 (95% CI, 0.20-0.88), specificity was 0.97 (95% CI, 0.92-0.99), PPV was 0.50 (95% CI, 0.17-0.82), NPV was 0.98 (95% CI, 0.93-0.99), PLR was 20.14 (95% CI, 6.3-64.2), and NLR was 0.44 (95% CI, 0.19-1.04). CONCLUSION Computer analysis of FHR and ST event signals provide higher accuracy in predicting neonatal academia.
Collapse
|
31
|
Wolfberg AJ, Norwitz ER. Probing the fetal cardiac signal for antecedents of brain injury. Clin Perinatol 2009; 36:673-84. [PMID: 19732620 DOI: 10.1016/j.clp.2009.06.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Obstetric care providers and researchers have long relied on analysis of the fetal heart rate tracing for insight into the fetal neurologic status. Although a normal fetal heart rate tracing does provide reassurance of intact neurologic function, an abnormal pattern is a very poor predictor of newborn brain injury. Indeed, if the clinical end point of interest is cerebral palsy, a non-reassuring fetal heart rate tracing has a 99% false positive rate. More recent analyses of fetal heart rate variability and fetal ECG waveforms, however, hold promise for improved diagnostic accuracy.
Collapse
Affiliation(s)
- Adam J Wolfberg
- Department of Obstetrics and Gynecology, Tufts University School of Medicine, Tufts Medical Center, Tufts Box 360, 800 Washington Street, Boston, MA 02111, USA.
| | | |
Collapse
|
32
|
Vayssière C, Tsatsaris V, Pirrello O, Cristini C, Arnaud C, Goffinet F. Inter-observer agreement in clinical decision-making for abnormal cardiotocogram (CTG) during labour: a comparison between CTG and CTG plus STAN. BJOG 2009; 116:1081-7; discussion 1087-8. [DOI: 10.1111/j.1471-0528.2009.02204.x] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
33
|
Melin M, Bonnevier A, Cardell M, Hogan L, Herbst A. Changes in the ST-interval segment of the fetal electrocardiogram in relation to acid-base status at birth. BJOG 2008; 115:1669-75. [DOI: 10.1111/j.1471-0528.2008.01949.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
34
|
Abstract
The last century has seen dramatic developments in medical care as technological advances have been applied to both diagnosis and treatment. Some areas of obstetrics have been slow to benefit from these advances – and none more so than the care of the fetus in labour.
Collapse
|
35
|
Abstract
PURPOSE OF REVIEW Though fetal arrhythmias account for a small proportion of referrals to a fetal cardiologist, they may be associated with significant morbidity and mortality. The present review outlines the current literature with regard to the diagnosis and, in brief, some management strategies in fetal arrhythmias. RECENT FINDINGS Advances in echocardiography have resulted in significant improvements in our ability to elucidate the mechanism of arrhythmia at the bedside. At the same time, magnetocardiography is broadening our understanding of mechanisms of arrhythmia especially as it pertains to ventricular arrhythmias and congenital heart block. It provides a unique window to study electrical properties of the fetal heart, unlike what has been available to date. Recent reports of bedside use of fetal ECG make it a promising new technology. Fetal magnetocardiography is also developing. The underlying mechanisms resulting in immune-mediated complete heart block in a small subset of 'at-risk' fetuses is under investigation. SUMMARY There have been great strides in noninvasive diagnosis of fetal arrhythmias. However, we still need to improve our knowledge of the electromechanical properties of the fetal heart as well as the mechanisms of arrhythmia to further improve outcomes. Multiinstitutional collaborative studies are needed to help answer some of the questions regarding patient, drug selection and management algorithms.
Collapse
|
36
|
Author response to: Review of the first 1502 cases of ECG-ST waveform analysis during labour in a teaching hospital. BJOG 2008. [DOI: 10.1111/j.1471-0528.2008.01719.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
37
|
Apantaku OO. Review of the first 1502 cases of ECG-ST waveform analysis during labour in a teaching hospital. BJOG 2008; 115:922-3; author reply 923-4. [PMID: 18485179 DOI: 10.1111/j.1471-0528.2008.01718.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
38
|
Abstract
PURPOSE OF REVIEW The assessment of fetal health has occupied our professional attention for many years. As the development of technologies for prenatal diagnostic techniques has progressed, applications of such technologies have aided in the overall assessment of fetal well-being. RECENT FINDINGS Fetal heart-rate monitoring remains the main form of fetal assessment for high-risk pregnancies. The additional assessments afforded by the analysis of ST and T-wave changes of the fetal electrocardiogram hold promise for improving the predictive value of fetal heart-rate assessments. Ultrasound has been invaluable for assessment of fetal anatomy, and the use of Doppler ultrasound has given insight into fetal cardiovascular responses to such conditions as intrauterine growth restriction and fetal anemia caused by red blood cell alloimmunization. SUMMARY As prenatal diagnostic techniques evolve, their application to the assessment of fetal well-being offers insight into pathophysiologic mechanisms of fetal disease, innovative tools to assess fetal health, and fertile ground for future investigation.
Collapse
|
39
|
Amer-Wahlin I, Arulkumaran S, Hagberg H, Marsál K, Visser GHA. Fetal electrocardiogram: ST waveform analysis in intrapartum surveillance. BJOG 2007; 114:1191-3. [PMID: 17877671 PMCID: PMC2239304 DOI: 10.1111/j.1471-0528.2007.01479.x] [Citation(s) in RCA: 85] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
ST waveform analysis of fetal electrocardiogram (ECG) for intrapartum surveillance (STAN) is a newly introduced method for fetal surveillance. The purpose of this commentary is to assist in the proper use of fetal ECG in combination with cardiotocography (CTG) during labour. Guidelines and recommendations concerning CTG and ST waveform interpretation and classification are stated that were agreed on by the European experts on ST waveform analysis for intrapartum surveillance during a meeting in Utretcht, the Netherlands in January 2007.
Collapse
Affiliation(s)
- I Amer-Wahlin
- Section of Obstetrics, Department of Obstetrics and Gynaecology, Karolinska University Hospital, Stockholm, Sweden.
| | | | | | | | | |
Collapse
|