Li P, Mei X, Ge W, Wu T, Zhong M, Huan N, Jiang Q, Hsu PL, Steinseifer U, Dong N, Zhang L. A comprehensive comparison of the in vitro hemocompatibility of extracorporeal centrifugal blood pumps. Front Physiol 2023; 14:1136545. [PMID: 37228828 PMCID: PMC10204736 DOI: 10.3389/fphys.2023.1136545] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 04/20/2023] [Indexed: 05/27/2023] Open
Abstract
Purpose: Blood damage has been associated with patients under temporary continuous-flow mechanical circulatory support. To evaluate the side effects caused by transit blood pumping, in vitro hemocompatibility testing for blood damage in pumps is considered a necessary reference before clinical trials. Methods: The hemocompatibility of five extracorporeal centrifugal blood pumps was investigated comprehensively, including four commercial pumps (the Abbott CentriMag, the Terumo Capiox, the Medos DP3, and the Medtronic BPX-80) and a pump in development (the magAssist MoyoAssist®). In vitro, hemolysis was tested with heparinized porcine blood at nominal operating conditions (5 L/min, 160 mmHg) and extreme operating conditions (1 L/min, 290 mmHg) using a circulation flow loop. Hematology analyses concerning the blood cell counts and the degradation of high-molecular-weight von Willebrand factor (VWF) during 6-h circulation were also evaluated. Results: Comparing the in vitro hemocompatibility of blood pumps at different operations, the blood damage was significantly more severe at extreme operating conditions than that at nominal operating conditions. The performance of the five blood pumps was arranged in different orders at these two operating conditions. The results also demonstrated superior hemocompatibility of CentriMag and MoyoAssist® at two operating conditions, with overall low blood damage at hemolysis level, blood cell counts, and degradation of high-molecular-weight VWF. It suggested that magnetic bearings have an advantage in hemocompatibility compared to the mechanical bearing of blood pumps. Conclusion: Involving multiple operating conditions of blood pumps in in vitro hemocompatibility evaluation will be helpful for clinical application. In addition, the magnetically levitated centrifugal blood pump MoyoAssist® shows great potential in the future as it demonstrated good in vitro hemocompatibility.
Collapse
Affiliation(s)
- Ping Li
- Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xu Mei
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Wanning Ge
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Tingting Wu
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Min Zhong
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Nana Huan
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Qiubo Jiang
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Po-Lin Hsu
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Nianguo Dong
- Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Liudi Zhang
- Artificial Organ Technology Lab, Biomanufacturing Centre, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| |
Collapse
|
2
|
Hatakenaka K, Hijikata W, Fujiwara T, Ohuchi K, Inoue Y. Prevention of thrombus formation in blood pump by mechanical circular orbital excitation of impeller in magnetically levitated centrifugal pump. Artif Organs 2023; 47:425-431. [PMID: 36305737 PMCID: PMC10098525 DOI: 10.1111/aor.14443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 09/22/2022] [Accepted: 10/15/2022] [Indexed: 02/03/2023]
Abstract
BACKGROUND Mechanical circulatory support devices, such as left ventricular assist devices, have recently been used in patients with heart failure as destination therapy but the formation of thrombus in blood pumps remains a critical problem. In this study, we propose a mechanical antithrombogenic method by impeller excitation using a magnetically levitated (Maglev) centrifugal pump. Previous studies have shown that one-directional excitation prevents thrombus; however, it is effective in only one direction. In this study, we aimed to obtain a better effect by vibrating it in a circular orbit to induce uniform changes in the shear-rate field entirely around the impeller. METHODS The blood coagulation time was compared using porcine blood. (1) The flow rate was set to 1 L/min, and applied excitation was at a frequency of 280 Hz and amplitude of 3 μm. (2) Moreover, the effect was compared by varying the frequency, amplitude, and direction of the excitation. In this experiment, the flow rate was set to 0.3 L/min. RESULTS (1) The thrombus formation time was 77 min without excitation and 133 min with excitation, which was 1.7 times longer. (2) The results showed no difference between (280 Hz, 3 μm) and (50 Hz, 16 μm) circular orbital excitations, and no directional difference, with thrombus formation of 2.5 times longer under all conditions than that without excitation. CONCLUSION In the case of simple reciprocating excitation, the time was approximately 1.2 times longer. This indicated that the circular orbital excitation is more effective.
Collapse
Affiliation(s)
- Kohei Hatakenaka
- School of Engineering, Tokyo Institute of Technology, Tokyo, Japan
| | - Wataru Hijikata
- School of Engineering, Tokyo Institute of Technology, Tokyo, Japan
| | - Tatsuki Fujiwara
- Department of Cardiovascular Surgery, Tokyo Medical and Dental University, Tokyo, Japan
| | - Katsuhiro Ohuchi
- Center for Experimental Animals, Tokyo Medical and Dental University, Tokyo, Japan
| | - Yusuke Inoue
- Advanced Medical Engineering Research Center, Asahikawa Medical University, Asahikawa, Japan
| |
Collapse
|
3
|
Sakurai H, Fujiwara T, Ohuchi K, Hijikata W, Inoue Y, Maruyama O, Tahara T, Yokota S, Tanaka Y, Takewa Y, Mizuno T, Arai H. Innovative experimental animal models for real-time comparison of antithrombogenicity between two oxygenators using dual extracorporeal circulation circuits and indocyanine green fluorescence imaging. Artif Organs 2023; 47:77-87. [PMID: 35957489 DOI: 10.1111/aor.14380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 07/08/2022] [Accepted: 08/02/2022] [Indexed: 01/04/2023]
Abstract
BACKGROUND Antithrombogenicity of extracorporeal membrane oxygenation (ECMO) devices, particularly oxygenators, is a current problem, with numerous studies and developments underway. However, there has been limited progress in developing methods to accurately compare the antithrombogenicity of oxygenators. Animal experiments are commonly conducted to evaluate the antithrombogenicity of devices; however, it is challenging to maintain a steady experimental environment. We propose an innovative experimental animal model to evaluate different devices in a constant experimental environment in real-time. METHODS This model uses two venous-arterial ECMO circuits attached to one animal (one by jugular vein and carotid artery, one by femoral vein and artery) and real-time assessment of thrombus formation in the oxygenator by indocyanine green (ICG) fluorescence imaging. Comparison studies were conducted using three pigs: one to compare different oxygenators (MERA vs. CAPIOX) (Case 1), and two to compare antithrombotic properties of the oxygenator (QUADROX) when used under different hydrodynamic conditions (continuous flow vs. pulsatile flow) (Cases 2 and 3). RESULTS Thrombi, visualized using ICG imaging, appeared as black dots on a white background in each oxygenator. In Case 1, differences in the site of thrombus formation and rate of thrombus growth were observed in real-time in two oxygenators. In Case 2 and 3, the thrombus region was smaller in pulsatile than in continuous conditions. CONCLUSIONS We devised an innovative experimental animal model for comparison of antithrombogenicity in ECMO circuits. This model enabled simultaneous evaluation of two different ECMO circuits under the same biological conditions and reduced the number of sacrificed experimental animals.
Collapse
Affiliation(s)
- Hironobu Sakurai
- Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tatsuki Fujiwara
- Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Katsuhiro Ohuchi
- Center for Experimental Animals, Tokyo Medical and Dental University, Tokyo, Japan
| | - Wataru Hijikata
- School of Engineering, Tokyo Institute of Technology, Tokyo, Japan
| | - Yusuke Inoue
- Advanced Medical Engineering Research Center, Asahikawa Medical University, Asahikawa, Japan
| | - Osamu Maruyama
- Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
| | - Tomoki Tahara
- Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Sachie Yokota
- Faculty of Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Yui Tanaka
- School of Engineering, Tokyo Institute of Technology, Tokyo, Japan
| | - Yoshiaki Takewa
- Advanced Medical Engineering Research Center, Asahikawa Medical University, Asahikawa, Japan
| | - Tomohiro Mizuno
- Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Hirokuni Arai
- Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
4
|
Kalbhenn J, Zieger B. Bleeding During Veno-Venous ECMO: Prevention and Treatment. Front Med (Lausanne) 2022; 9:879579. [PMID: 35677828 PMCID: PMC9168900 DOI: 10.3389/fmed.2022.879579] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Accepted: 04/27/2022] [Indexed: 11/26/2022] Open
Abstract
Veno-venous extracorporeal membrane oxygenation (vvECMO) has become a routine treatment for severe lung failure in specialized centers. Spontaneous bleeding complications, however, are observed in 30–60% of patients during vvECMO treatment. Bleeding increases mortality by factors 2–3. Anticoagulation in combination with several acquired bleeding disorders caused by the mechanical pump and the foreign layer of the extracorporeal system contribute to the risk of bleeding. In this review, the mechanisms of the underlying pathologies and the route from diagnosis to treatment are described.
Collapse
Affiliation(s)
- Johannes Kalbhenn
- Department of Anesthesiology and Critical Care, Faculty of Medicine, Medical Center—University of Freiburg, Freiburg im Breisgau, Germany
- *Correspondence: Johannes Kalbhenn ; orcid.org/0000-0001-7551-5082
| | - Barbara Zieger
- Division of Pediatric Hematology and Oncology, Department of Pediatrics and Adolescent Medicine, Faculty of Medicine, Medical Center—University of Freiburg, Freiburg im Breisgau, Germany
| |
Collapse
|
5
|
Tompkins LH, Prina SR, Gellman BN, Morello GF, Roussel T, Kopechek JA, Williams SJ, Petit PC, Slaughter MS, Koenig SC, Dasse KA. Development of Inspired Therapeutics Pediatric VAD: Benchtop Evaluation of Impeller Performance and Torques for MagLev Motor Design. Cardiovasc Eng Technol 2022; 13:307-317. [PMID: 34518953 PMCID: PMC8918059 DOI: 10.1007/s13239-021-00578-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Accepted: 08/22/2021] [Indexed: 12/01/2022]
Abstract
PURPOSE Despite the availability of first-generation extracorporeal mechanical circulatory support (MCS) systems that are widely used throughout the world, there is a need for the next generation of smaller, more portable devices (designed without cables and a minimal number of connectors) that can be used in all in-hospital and transport settings to support patients in heart failure. Moreover, a system that can be universally used for all indications for use including cardiopulmonary bypass (CPB), uni- or biventricular support (VAD), extracorporeal membrane oxygenation (ECMO) and respiratory assist that is suitable for use for adult, neonate, and pediatric patients is desirable. Providing a single, well designed, universal technology could reduce the incidence of human errors by limiting the need for training of hospital staff on a single system for a variety of indications throughout the hospital rather than having to train on multiple complex systems. The objective of this manuscript is to describe preliminary research to develop the first prototype pump for use as a ventricular assist device for pediatric patients with the Inspired Universal MCS technology. The Inspired VAD Universal System is an innovative extracorporeal blood pumping system utilizing novel MagLev technology in a single portable integrated motor/controller unit which can power a variety of different disposable pump modules intended for neonate, pediatric, and adult ventricular and respiratory assistance. METHODS A prototype of the Inspired Pediatric VAD was constructed to determine the hemodynamic requirements for pediatric applications. The magnitude/range of hydraulic torque of the internal impeller was quantified. The hydrodynamic performance of the prototype pump was benchmarked using a static mock flow loop model containing a heated blood analogue solution to test the pump over a range of rotational speeds (500-6000 RPM), flow rates (0-3.5 L/min), and pressures (0 to ~ 420 mmHg). The device was initially powered by a shaft-driven DC motor in lieu of a full MagLev design, which was also used to calculate the fluid torque acting on the impeller. RESULTS The pediatric VAD produced flows as high as 4.27 L/min against a pressure of 127 mmHg at 6000 RPM and the generated pressure and flow values fell within the desired design specifications. CONCLUSIONS The empirically determined performance and torque values establish the requirements for the magnetically levitated motor design to be used in the Inspired Universal MagLev System. This next step in our research and development is to fabricate a fully integrated and functional magnetically levitated pump, motor and controller system that meets the product requirement specifications and achieves a state of readiness for acute ovine animal studies to verify safety and performance of the system.
Collapse
Affiliation(s)
- Landon H Tompkins
- Department of Bioengineering, University of Louisville, Louisville, KY, 40202, USA
| | | | - Barry N Gellman
- Inspired Therapeutics LLC, 125 E. Merritt Island Cswy, #107-341, Merritt Island, FL, 32925, USA
| | | | - Thomas Roussel
- Department of Bioengineering, University of Louisville, Louisville, KY, 40202, USA
| | - Jonathan A Kopechek
- Department of Bioengineering, University of Louisville, Louisville, KY, 40202, USA
| | - Stuart J Williams
- Department of Mechanical Engineering, University of Louisville, Louisville, KY, 40202, USA
| | - Priscilla C Petit
- Inspired Therapeutics LLC, 125 E. Merritt Island Cswy, #107-341, Merritt Island, FL, 32925, USA
| | - Mark S Slaughter
- Department of Cardiovascular and Thoracic Surgery, University of Louisville, Louisville, KY, 40202, USA
| | - Steven C Koenig
- Departments of Bioengineering and CT Surgery, Cardiovascular Innovation Institute, University of Louisville, 302 East Muhammad Ali Blvd, Room 408, Louisville, KY, 40202, USA.
| | - Kurt A Dasse
- Inspired Therapeutics LLC, 125 E. Merritt Island Cswy, #107-341, Merritt Island, FL, 32925, USA.
- Departments of Bioengineering and CT Surgery, Cardiovascular Innovation Institute, University of Louisville, 302 East Muhammad Ali Blvd, Room 408, Louisville, KY, 40202, USA.
| |
Collapse
|
6
|
Jiang M, Sakota D, Kosaka R, Hijikata W. Analysis of Plasma Skimming within a Hydrodynamic Bearing Gap for Designing Spiral Groove Bearings in Rotary Blood Pumps. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:1213-1217. [PMID: 34891505 DOI: 10.1109/embc46164.2021.9629535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The blood damage problem inside the narrow hydrodynamic bearing is potentially considered to be solved by applying plasma skimming. However, the consideration of improving plasma skimming has not been included in the design of hydrodynamic bearings. The absence of experimental investigation on revealing the relationship between blood flow and plasma skimming in the bearing gap impedes the design of groove shape for plasma skimming. Thus, the present study was undertaken to evaluate how the blood flow direction and the groove shape affect plasma skimming in the bearing gap. To this end, blood tests using porcine blood were repeated three times with a hematocrit of 0.8%. The bearing gap during the tests was adjusted to 25 µm and the rotational speed was adjusted from 50 rpm to 2500 rpm. The blood flow and plasma skimming effect was evaluated based on image analysis utilizing a high-speed microscope. Results of three tests indicated that the flow direction of RBCs was dominated by the rotating surface in the bearing gap when the rotational speed increased over 1200 rpm. The best plasma skimming effect was observed when the angle between the flow direction of RBCs and the tangent line of the groove was within -10 degrees to 10 degrees. The future study will be conducted with including the consideration of plasma skimming in the bearing shape design. The findings in this study aid the future design and development of hydrodynamic bearing for use in rotary blood pumps.
Collapse
|
7
|
Seki H, Fujiwara T, Hijikata W, Murashige T, Tahara T, Yokota S, Ogata A, Ohuchi K, Mizuno T, Arai H. Evaluation of real-time thrombus detection method in a magnetically levitated centrifugal blood pump using a porcine left ventricular assist circulation model. Artif Organs 2021; 45:726-735. [PMID: 33432615 DOI: 10.1111/aor.13915] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 12/16/2020] [Accepted: 01/04/2021] [Indexed: 01/08/2023]
Abstract
Pump thrombosis induces significant complications and requires timely detection. We proposed real-time monitoring of pump thrombus in a magnetically levitated centrifugal blood pump (mag-lev pump) without using additional sensors, by focusing on the changes in the displacement of the pump impeller. The phase difference between the current and displacement of the impeller increases with pump thrombus. This thrombus detection method was previously evaluated through simulated circuit experiments using porcine blood. Evaluation of real-time thrombus detection in a mag-lev blood pump was performed using a porcine left ventricular assist circulation model in this study. Acute animal experiments were performed five times using five Japanese domestic pigs. To create thrombogenic conditions, fibrinogen coating that induces thrombus formation in a short time was applied to the inner surfaces of the pump. An inflow and an outflow cannula were inserted into the apex of the left ventricle and the carotid artery, respectively, by a minimally invasive surgical procedure that allowed minimal bleeding and hypothermia. Pump flow was maintained at 1 L/min without anticoagulation. The vibrational frequency of the impeller (70 Hz) and its vibrational amplitude (30 μm) were kept constant. The thrombus was detected based on the fact that the phase difference between the impeller displacement and input current to the magnetic bearing increases when a thrombus is formed inside a pump. The experiment was terminated when the phase difference increased by over 1° from the lowest value or when the phase difference was at the lowest value 12 hours after commencing measurements. The phase difference increased by over 1° in three cases. The pump was stopped after 12 hours in two cases. Pump thrombi were found in the pump in three cases in which the phase difference increased by over 1°. No pump thrombus was found in the other two cases in which the phase difference did not increase. We succeeded in real-time thrombus monitoring of a mag-lev pump in acute animal experiments.
Collapse
Affiliation(s)
- Haruna Seki
- Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tatsuki Fujiwara
- Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Wataru Hijikata
- School of Engineering, Tokyo Institute of Technology, Tokyo, Japan
| | - Tomotaka Murashige
- School of Engineering, Tokyo Institute of Technology, Tokyo, Japan.,Department of Advanced Surgical Technology Research and Development, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tomoki Tahara
- Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Sachie Yokota
- Faculty of Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Asato Ogata
- Faculty of Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Katsuhiro Ohuchi
- Department of Advanced Surgical Technology Research and Development, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tomohiro Mizuno
- Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Hirokuni Arai
- Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
8
|
Hemocompatibility of new magnetically-levitated centrifugal pump technology compared to the CentriMag adult pump. Sci Rep 2020; 10:22055. [PMID: 33328596 PMCID: PMC7744571 DOI: 10.1038/s41598-020-78709-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Accepted: 11/26/2020] [Indexed: 11/25/2022] Open
Abstract
The specific hemocompatibility properties of mechanical-circulatory-support (MCS)-pump technologies have not previously been described in a comparable manner. We thus investigated the hemocompatibility-indicating marker of a new magnetically-levitated (MagLev) centrifugal pump (MT-Mag) in a human, whole-blood mock-loop for 360 min using the MCS devices as a driving component. We compared those results with the CentriMag adult (C-Mag) device under the same conditions according to ISO10993-4. Blood samples were analyzed via enzyme-linked-immunosorbent-assay (ELISA) for markers of coagulation, complement system, and the inflammatory response. The time-dependent activation of the coagulation system was measured by detecting thrombin-anti-thrombin complexes (TAT). The activation of the complement system was determined by increased SC5b-9 levels in both groups. A significant activation of neutrophils (PMN-elastase) was detected within the C-Mag group, but not in the MT-Mag group. However, the amount of PMN-elastase at 360 min did not differ significantly between groups. The activation of the complement and coagulation system was found to be significantly time-dependent in both devices. However, coagulation activation as determined by the TAT level was lower in the MT-Mag group than in the C-Mag group. This slight disparity could have been achieved by the optimized secondary flow paths and surface coating, which reduces the interaction of the surface with blood.
Collapse
|
9
|
An Equivalent Circuit Analysis and Suspension Characteristics of AC Magnetic Suspension Using Magnetic Resonant Coupling. ACTUATORS 2020. [DOI: 10.3390/act9030052] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The fundamental characteristics and performances of alternating current (AC) magnetic suspension using magnetic resonant coupling are studied analytically and experimentally. Nowadays, wireless power transfer to the suspended object is required during non-contact suspension in some applications. Therefore, magnetic resonant coupling has been introduced for AC magnetic suspension to achieve self-stabilizing magnetic suspension and energy transfer to the floator simultaneously. The effect of circuit parameters for developing an experimental apparatus and performances are predicted from the solution of the equivalent circuits analytically. First, an equivalent magnetic circuit is derived and analyzed to characterize the self-inductance and mutual inductance with the gap. Second, an equivalent electrical circuit is analyzed to derive the current and force equations including magnetic parameters of the circuit. The derivation of these equations is numerically solved to study the characteristics of the primary current, the secondary current, and the force with respect to the gap and the applied frequency. The comparison between theoretical and experimental results is depicted, and the reason for differences is explained. The experimental and theoretical results show that positive stiffness is possible, which is essential for achieving self-stabilization. The self-stability is confirmed by the frequency response of the suspension system to disturbance experimentally.
Collapse
|
10
|
Seki H, Fujiwara T, Hijikata W, Murashige T, Maruyama T, Yokota S, Ogata A, Ouchi K, Mizuno T, Arai H. Verification of a thrombus induction method at the target point inside the blood pump using a fibrinogen coating for a thrombus detection study. Artif Organs 2020; 44:968-975. [DOI: 10.1111/aor.13743] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Revised: 05/19/2020] [Accepted: 05/22/2020] [Indexed: 11/26/2022]
Affiliation(s)
- Haruna Seki
- Department of Cardiovascular Surgery Tokyo Medical and Dental University Graduate School of Medical and Dental Sciences Tokyo Japan
| | - Tatsuki Fujiwara
- Department of Cardiovascular Surgery Tokyo Medical and Dental University Graduate School of Medical and Dental Sciences Tokyo Japan
| | - Wataru Hijikata
- School of Engineering Tokyo Institute of Technology Tokyo Japan
| | | | - Takuro Maruyama
- School of Engineering Tokyo Institute of Technology Tokyo Japan
| | - Sachie Yokota
- Faculty of Medicine Tokyo Medical and Dental University Tokyo Japan
| | - Asato Ogata
- Faculty of Medicine Tokyo Medical and Dental University Tokyo Japan
| | - Katsuhiro Ouchi
- Department of Advanced Surgical Technology Research and Development Tokyo Medical and Dental University Tokyo Japan
| | - Tomohiro Mizuno
- Department of Cardiovascular Surgery Tokyo Medical and Dental University Graduate School of Medical and Dental Sciences Tokyo Japan
| | - Hirokuni Arai
- Department of Cardiovascular Surgery Tokyo Medical and Dental University Graduate School of Medical and Dental Sciences Tokyo Japan
| |
Collapse
|
11
|
Berdajs D, von Segesser LK, Maisano F, Milano G, Ferrari E. Performance characteristics of the new Eurosets magnetically suspended centrifugal pump. Perfusion 2020; 36:183-189. [PMID: 32567504 DOI: 10.1177/0267659120931990] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVE The aim was to evaluate the performance of a newly developed magnetically suspended centrifugal pump head intended for use as a ventricular assistance device with a newly developed extracorporeal membrane oxygenator setup. METHODS In an experimental setup, an extracorporeal membrane oxygenator circuit was established in three calves with a mean weight of 68.2 ± 2.0 kg. A magnetically levitated centrifugal pump was tested, along with a newly designed extracorporeal membrane oxygenator console, at three different flow ranges: (a) 0.0 to 5.2 L/min, (b) 0.0 to 7.1 L/min, and (c) 0.0 to 6.0 L/min. For each setup, the animals were supported by a circuit for 6 h. Blood samples were collected just before caridiopulmonary bypass (CPB) after 10 min on bypass and after 1, 2, 5, and 6 h of perfusion for hemolysis determination and biochemical tests. Values were recorded for blood pressure, mean flow, and pump rotational speed. Analysis of variance was used for repeated measurements. RESULTS Mean pump flows achieved during the three 6 h pump runs for the three pump heads studied were as follows: (a) flow range 0.0 to 5.2 L/min, 3.6 ± 1.5 L/min, (b) flow range 0.0 to 7.1 L/min, 4.9 ± 1.3 L/min, and (c) flow range 0.0 to 6.0 L/min, 3.8 ± 1.5 L/min. Blood trauma, evaluated by plasma hemoglobin and lactate dehydrogenase levels, did not help in detecting any significant hemolysis. Thrombocytes and white blood cell count profiles showed no significant differences between the groups at the end of the 6 h perfusion. At the end of testing, no clot deposition was found in the oxygenator, and there was no evidence of peripheral emboli. CONCLUSION The results suggest that the newly developed magnetically suspended centrifugal pump head provides satisfactory hydrodynamic performance in an acute perfusion scenario without increasing hemolysis.
Collapse
Affiliation(s)
- Denis Berdajs
- Department of Cardiac Surgery, University Hospital of Basel, Basel, Switzerland
| | - Ludwig K von Segesser
- Department of Surgery and Anesthesiology, Cardio-Vascular Research, Lausanne, Switzerland
| | - Francesco Maisano
- Department of Cardiac Surgery, University Hospital of Zurich, Zurich, Switzerland
| | - Guiseppina Milano
- Department of Surgery and Anesthesiology, Cardio-Vascular Research, Lausanne, Switzerland
| | - Enrico Ferrari
- Department of Surgery and Anesthesiology, Cardio-Vascular Research, Lausanne, Switzerland
| |
Collapse
|
12
|
Hijikata W, Maruyama T, Murashige T, Sakota D, Maruyama O. Detection of thrombosis in a magnetically levitated blood pump by vibrational excitation of the impeller. Artif Organs 2020; 44:594-603. [DOI: 10.1111/aor.13632] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2019] [Revised: 11/28/2019] [Accepted: 01/03/2020] [Indexed: 12/15/2022]
Affiliation(s)
- Wataru Hijikata
- School of Engineering Tokyo Institute of Technology Tokyo Japan
| | - Takuro Maruyama
- School of Engineering Tokyo Institute of Technology Tokyo Japan
| | | | - Daisuke Sakota
- National Institute of Advanced Industrial Science and Technology Tsukuba Japan
| | - Osamu Maruyama
- National Institute of Advanced Industrial Science and Technology Tsukuba Japan
| |
Collapse
|
13
|
Jiang M, Murashige T, Sakota D, Hijikata W. Evaluating Plasma Skimming with Whole Blood in Small Gap Region Imitating Clearance of Blood Pumps. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:5665-5669. [PMID: 31947138 DOI: 10.1109/embc.2019.8857735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Plasma skimming is the phenomenon whereby the discharge hematocrit is lower than feed hematocrit naturally occurring in the microvessels with Poiseuille flow. It has been studied in Poiseuille flow extensively. Besides, plasma skimming has also been observed and investigated in blood pumps due to its potential to prevent hemolysis by skimming blood cells out of the small gap. However, whether plasma skimming occurs in blood pumps with whole blood has not been verified. Additionally, the independent influence of rotational speed and gap size has not been clarified. Therefore, in order to lay the foundation of applying plasma skimming to the development of blood pumps and also investigate the influence of rotational speed and gap size on plasma skimming respectively, we designed a simplified geometric device which not only imitates the flow inside clearances of blood pumps, but also provides different rotational speed and gap size conditions. We first conducted the verification tests of plasma skimming using whole blood with an initial hematocrit of 44% and the gap size was varied from 10 μm to 240 μm with 10 μm interval. The plasma skimming was verified occurring when the gap was less than 70 μm at a rotational speed of 800 rpm. Since plasma skimming was confirmed, we employed 30% hematocrit blood and performed the following tests to evaluate the influence of rotational speed of 600 rpm, 700 rpm, and 800 rpm respectively. As a result, the hematocrit of sampled blood declined as the rotational speed increased from 600 rpm to 800 rpm. And there was the lowest hematocrit of 16% when the gap was adjusted to 50 μm gap size at 800 rpm. This study further promotes the possibility of applying plasma skimming to the blood pumps with higher hemocapability.
Collapse
|
14
|
Miniaturized Test Loop for the Assessment of Blood Damage by Continuous-Flow Left-Ventricular Assist Devices. Ann Biomed Eng 2019; 48:768-779. [PMID: 31724071 DOI: 10.1007/s10439-019-02404-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Accepted: 11/06/2019] [Indexed: 01/22/2023]
Abstract
Although the hemocompatibility of left-ventricular assist devices (LVADs) has continuously improved, assessment of hemolysis remains mandatory in pre-clinical testing. The ASTM-F1841 has standardized this assessment since 1997. However, the recommended usage of fresh, non-pooled human blood is hardly feasible with the test loop volume specified therein, when testing the device under test versus a predicate device as required by the international standard 10993-4. In this study, we compared ASTM-conforming (ASTM) and downscaled (mini) test loops with a one-third priming volume for the assessment of blood damage at the ASTM operating point. Blood damage was assessed for HeartMate 3 and BPX-80 in 6 experiments with heparinized porcine slaughterhouse blood for 6 h. We analyzed plasma free hemoglobin (pfHb), von Willebrand factor (vWF) concentration and collagen-binding functionality and calculated indices of hemolysis and vWF-ratios. The mini test loops provided significantly higher pfHb increase and consistently stronger vWF-ratio decrease and yielded a significantly better differentiation of the pumps. Interestingly, indices of hemolysis were generally lower in the mini set-up, indicating less adverse effects by the mini loop itself. Thus, we propose our mini test loop as suitable tool for clinically relevant standardized assessment of blood damage by future LVADs with single-donation human blood.
Collapse
|
15
|
Murashige T, Hijikata W. Mechanical antithrombogenic properties by vibrational excitation of the impeller in a magnetically levitated centrifugal blood pump. Artif Organs 2019; 43:849-859. [DOI: 10.1111/aor.13541] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Revised: 07/11/2019] [Accepted: 07/12/2019] [Indexed: 11/27/2022]
Affiliation(s)
- Tomotaka Murashige
- Department of Mechanical Engineering, School of Engineering Tokyo Institute of Technology Meguro Japan
| | - Wataru Hijikata
- Department of Mechanical Engineering, School of Engineering Tokyo Institute of Technology Meguro Japan
| |
Collapse
|
16
|
Hijikata W, Maruyama T, Suzumori Y, Shinshi T. Measuring real-time blood viscosity with a ventricular assist device. Proc Inst Mech Eng H 2019; 233:562-569. [DOI: 10.1177/0954411919838738] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Ventricular assist devices assist in blood circulation and form a crucial component of artificial hearts. While it is important to measure parameters such as the flow rate, pressure head and viscosity of the blood, implanting additional devices to do such measurements is inadvisable. To this end, we demonstrate the adaptation of a ventricular assist device for the purpose of measuring blood viscosity. Such an approach eliminates the need for additional dedicated viscometers in artificial hearts. In the proposed method, the blood viscosity is measured by applying radial vibrational excitation to the impeller in a ventricular assist device using its magnetic levitation system. During the measurement, blood is exposed to a combination of a low shear rate (≈100/s) generated by the radial vibration of the impeller and a high shear rate (>10,000/s) generated by the impeller’s rotation. The apparent viscosity of blood depends on the shear rate, so we determined which shear rate was the dominant one in the proposed method. The measurement results showed that the viscosity measured by the proposed method was in good agreement with the reference viscosity measured with a high shear rate. The mean absolute deviation in the measurements using the proposed method and those obtained using a concentric cylindrical viscometer at a high shear rate was 0.12 mPa s for four samples of porcine blood, with viscosities ranging from 2.32 to 2.75 mPa s.
Collapse
Affiliation(s)
- Wataru Hijikata
- School of Engineering, Tokyo Institute of Technology, Tokyo, Japan
| | - Takuro Maruyama
- School of Engineering, Tokyo Institute of Technology, Tokyo, Japan
| | - Yuki Suzumori
- Laboratory for Future Interdisciplinary Research of Science and Technology, Tokyo Institute of Technology, Yokohama, Japan
| | - Tadahiko Shinshi
- Laboratory for Future Interdisciplinary Research of Science and Technology, Tokyo Institute of Technology, Yokohama, Japan
| |
Collapse
|
17
|
Hosseinipour M, Gupta R, Bonnell M, Elahinia M. Rotary mechanical circulatory support systems. J Rehabil Assist Technol Eng 2017; 4:2055668317725994. [PMID: 31186935 PMCID: PMC6453075 DOI: 10.1177/2055668317725994] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2017] [Accepted: 07/20/2017] [Indexed: 12/25/2022] Open
Abstract
A detailed survey of the current trends and recent advances in rotary mechanical
circulatory support systems is presented in this paper. Rather than clinical reports, the
focus is on technological aspects of these rehabilitating devices as a reference for
engineers and biomedical researchers. Existing trends in flow regimes, flow control, and
bearing mechanisms are summarized. System specifications and applications of the most
prominent continuous-flow ventricular assistive devices are provided. Based on the flow
regime, pumps are categorized as axial flow, centrifugal flow, and mixed flow. Unique
characteristics of each system are unveiled through an examination of the structure,
bearing mechanism, impeller design, flow rate, and biocompatibility. A discussion on the
current limitations is provided to invite more studies and further improvements.
Collapse
Affiliation(s)
- Milad Hosseinipour
- Dynamic and Smart Systems Laboratory, The University of Toledo, Toledo, OH, USA.,Department of Mechanical Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
| | - Rajesh Gupta
- Cardiovascular Medicine Division, The University of Toledo Medical Center, Toledo, OH, USA
| | - Mark Bonnell
- Cardiothoracic Surgery Division, The University of Toledo Medical Center, Toledo, OH, USA
| | - Mohammad Elahinia
- Dynamic and Smart Systems Laboratory, The University of Toledo, Toledo, OH, USA
| |
Collapse
|
18
|
Paul G, Rezaienia MA, Rahideh A, Munjiza A, Korakianitis T. The Effects of Ambulatory Accelerations on the Stability of a Magnetically Suspended Impeller for an Implantable Blood Pump. Artif Organs 2016; 40:867-76. [DOI: 10.1111/aor.12749] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2015] [Revised: 01/25/2016] [Accepted: 03/01/2016] [Indexed: 11/30/2022]
Affiliation(s)
- Gordon Paul
- School of Engineering and Materials Science; Queen Mary University of London; London UK
| | | | - Akbar Rahideh
- School of Electrical and Computer Engineering; Shiraz University; Shiraz Iran
| | - Ante Munjiza
- School of Engineering and Materials Science; Queen Mary University of London; London UK
| | - Theodosios Korakianitis
- Parks College of Engineering; Aviation and Technology, Saint Louis University; St. Louis MO USA
| |
Collapse
|
19
|
Koprivanac M, Kelava M, Soltesz E, Smedira N, Kapadia S, Brzezinski A, Alansari S, Moazami N. Advances in temporary mechanical support for treatment of cardiogenic shock. Expert Rev Med Devices 2015; 12:689-702. [DOI: 10.1586/17434440.2015.1086265] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
20
|
Murashige T, Kosaka R, Sakota D, Nishida M, Kawaguchi Y, Yamane T, Maruyama O. Evaluation of a Spiral Groove Geometry for Improvement of Hemolysis Level in a Hydrodynamically Levitated Centrifugal Blood Pump. Artif Organs 2015; 39:710-4. [PMID: 26146791 DOI: 10.1111/aor.12546] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The purpose of this study is to evaluate a spiral groove geometry for a thrust bearing to improve the hemolysis level in a hydrodynamically levitated centrifugal blood pump. We compared three geometric models: (i) the groove width is the same as the ridge width at any given polar coordinate (conventional model); (ii) the groove width contracts inward from 9.7 to 0.5 mm (contraction model); and (iii) the groove width expands inward from 0.5 to 4.2 mm (expansion model). To evaluate the hemolysis level, an impeller levitation performance test and in vitro hemolysis test were conducted using a mock circulation loop. In these tests, the driving conditions were set at a pressure head of 200 mm Hg and a flow rate of 4.0 L/min. As a result of the impeller levitation performance test, the bottom bearing gaps of the contraction and conventional models were 88 and 25 μm, respectively. The impeller of the expansion model touched the bottom housing. In the hemolysis test, the relative normalized index of hemolysis (NIH) ratios of the contraction model in comparison with BPX-80 and HPM-15 were 0.6 and 0.9, respectively. In contrast, the relative NIH ratios of the conventional model in comparison with BPX-80 and HPM-15 were 9.6 and 13.7, respectively. We confirmed that the contraction model achieved a large bearing gap and improved the hemolysis level in a hydrodynamically levitated centrifugal blood pump.
Collapse
Affiliation(s)
- Tomotaka Murashige
- Graduate School of Science and Technology, Tokyo University of Science, Noda, Chiba, Japan
| | - Ryo Kosaka
- National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan
| | - Daisuke Sakota
- National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan
| | - Masahiro Nishida
- National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan
| | | | - Takashi Yamane
- National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan.,Kobe University, Kobe, Hyogo, Japan
| | - Osamu Maruyama
- National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan
| |
Collapse
|
21
|
Hijikata W, Rao J, Abe S, Takatani S, Shinshi T. Sensorless Viscosity Measurement in a Magnetically-Levitated Rotary Blood Pump. Artif Organs 2015; 39:559-68. [DOI: 10.1111/aor.12440] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Wataru Hijikata
- Precision and Intelligence Laboratory; Tokyo Institute of Technology; Yokohama Japan
| | - Jun Rao
- Interdisciplinary Graduate School of Science and Engineering; Tokyo Institute of Technology; Yokohama Japan
| | - Shodai Abe
- Interdisciplinary Graduate School of Science and Engineering; Tokyo Institute of Technology; Yokohama Japan
| | - Setsuo Takatani
- Division of Research and Development; MedTech Heart Inc.; Tokyo Japan
- Department of Cardiovascular Surgery; Nihon University School of Medicine; Tokyo Japan
| | - Tadahiko Shinshi
- Precision and Intelligence Laboratory; Tokyo Institute of Technology; Yokohama Japan
| |
Collapse
|
22
|
Nagaoka E, Fujiwara T, Kitao T, Sakota D, Shinshi T, Arai H, Takatani S. MedTech Mag-Lev, Single-use, Extracorporeal Magnetically Levitated Centrifugal Blood Pump for Mid-term Circulatory Support. ASAIO J 2013; 59:246-52. [DOI: 10.1097/mat.0b013e31828a75e3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
23
|
Fujiwara T, Nagaoka E, Watanabe T, Miyagi N, Kitao T, Sakota D, Mamiya T, Shinshi T, Arai H, Takatani S. New generation extracorporeal membrane oxygenation with MedTech Mag-Lev, a single-use, magnetically levitated, centrifugal blood pump: preclinical evaluation in calves. Artif Organs 2013; 37:447-56. [PMID: 23489176 DOI: 10.1111/aor.12006] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We have evaluated the feasibility of a newly developed single-use, magnetically levitated centrifugal blood pump, MedTech Mag-Lev, in a 3-week extracorporeal membrane oxygenation (ECMO) study in calves against a Medtronic Bio-Pump BPX-80. A heparin- and silicone-coated polypropylene membrane oxygenator MERA NHP Excelung NSH-R was employed as an oxygenator. Six healthy male Holstein calves with body weights of about 100 kg were divided into two groups, four in the MedTech group and two in the Bio-Pump group. Under general anesthesia, the blood pump and oxygenator were inserted extracorporeally between the main pulmonary artery and the descending aorta via a fifth left thoracotomy. Postoperatively, both the pump and oxygen flow rates were controlled at 3 L/min. Heparin was continuously infused to maintain the activated clotting time at 200-240 s. All the MedTech ECMO calves completed the study duration. However, the Bio-Pump ECMO calves were terminated on postoperative days 7 and 10 because of severe hemolysis and thrombus formation. At the start of the MedTech ECMO, the pressure drop across the oxygenator was about 25 mm Hg with the pump operated at 2800 rpm and delivering 3 L/min flow. The PO2 of the oxygenator outlet was higher than 400 mm Hg with the PCO2 below 45 mm Hg. Hemolysis and thrombus were not seen in the MedTech ECMO circuits (plasma-free hemoglobin [PFH] < 5 mg/dL), while severe hemolysis (PFH > 20 mg/dL) and large thrombus were observed in the Bio-Pump ECMO circuits. Plasma leakage from the oxygenator did not occur in any ECMO circuits. Three-week cardiopulmonary support was performed successfully with the MedTech ECMO without circuit exchanges. The MedTech Mag-Lev could help extend the durability of ECMO circuits by the improved biocompatible performances.
Collapse
Affiliation(s)
- Tatsuki Fujiwara
- Department of Cardiovascular Surgery, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo, Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Hijikata W, Mamiya T, Shinshi T, Takatani S. A cost-effective extracorporeal magnetically-levitated centrifugal blood pump employing a disposable magnet-free impeller. Proc Inst Mech Eng H 2011; 225:1149-57. [DOI: 10.1177/0954411911422842] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In the field of rotary blood pumps, contactless support of the impeller by a magnetic bearing has been identified as a promising method to reduce blood damage and enhance durability. The authors developed a two-degrees-of-freedom radial controlled magnetic bearing system without a permanent magnet in the impeller in order that a low-cost disposable pump-head for an extracorporeal centrifugal blood pump could be manufactured more easily. Stable levitation and contactless rotation of the ‘magnet-free’ impeller were realized for a prototype blood-pump that made use of this magnetic bearing. The run-out of the impeller position at between 1000 r/min and 3000 r/min was less than 40 µm in the radial-controlled directions. The total power consumption of the magnetic bearing was less than 1 W at the same rotational speeds. When the pump was operated, a flow rate of 5 l/min against a head pressure of 78.66 kPa was achieved at a rotational speed of 4000 r/min, which is sufficient for extracorporeal circulation support. The proposed technology offers the advantage of low-cost mass production of disposable pump heads.
Collapse
Affiliation(s)
- W Hijikata
- Tokyo Institute of Technology, Precision and Intelligence Laboratory, Yokohama, Japan
| | - T Mamiya
- Tokyo Institute of Technology, Interdisciplinary Graduate School of Science and Engineering, Yokohama, Japan
| | - T Shinshi
- Tokyo Institute of Technology, Precision and Intelligence Laboratory, Yokohama, Japan
| | - S Takatani
- Tokyo Medical and Dental University, Institute of Biomaterials and Bioengineering, Tokyo, Japan
| |
Collapse
|
25
|
Fraser KH, Taskin ME, Griffith BP, Wu ZJ. The use of computational fluid dynamics in the development of ventricular assist devices. Med Eng Phys 2011; 33:263-80. [PMID: 21075669 PMCID: PMC3053072 DOI: 10.1016/j.medengphy.2010.10.014] [Citation(s) in RCA: 157] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2010] [Revised: 10/12/2010] [Accepted: 10/15/2010] [Indexed: 02/06/2023]
Abstract
Progress in the field of prosthetic cardiovascular devices has significantly contributed to the rapid advancements in cardiac therapy during the last four decades. The concept of mechanical circulatory assistance was established with the first successful clinical use of heart-lung machines for cardiopulmonary bypass. Since then a variety of devices have been developed to replace or assist diseased components of the cardiovascular system. Ventricular assist devices (VADs) are basically mechanical pumps designed to augment or replace the function of one or more chambers of the failing heart. Computational Fluid Dynamics (CFD) is an attractive tool in the development process of VADs, allowing numerous different designs to be characterized for their functional performance virtually, for a wide range of operating conditions, without the physical device being fabricated. However, VADs operate in a flow regime which is traditionally difficult to simulate; the transitional region at the boundary of laminar and turbulent flow. Hence different methods have been used and the best approach is debatable. In addition to these fundamental fluid dynamic issues, blood consists of biological cells. Device-induced biological complications are a serious consequence of VAD use. The complications include blood damage (haemolysis, blood cell activation), thrombosis and emboli. Patients are required to take anticoagulation medication constantly which may cause bleeding. Despite many efforts blood damage models have still not been implemented satisfactorily into numerical analysis of VADs, which severely undermines the full potential of CFD. This paper reviews the current state of the art CFD for analysis of blood pumps, including a practical critical review of the studies to date, which should help device designers choose the most appropriate methods; a summary of blood damage models and the difficulties in implementing them into CFD; and current gaps in knowledge and areas for future work.
Collapse
Affiliation(s)
- Katharine H Fraser
- Department of Surgery, University of Maryland School of Medicine, Baltimore, MD 21201, USA
| | | | | | | |
Collapse
|
26
|
Nagaoka E, Someya T, Kitao T, Kimura T, Ushiyama T, Hijikata W, Shinshi T, Arai H, Takatani S. Development of a Disposable Magnetically Levitated Centrifugal Blood Pump (MedTech Dispo) Intended for Bridge-to-Bridge Applications-Two-Week In Vivo Evaluation. Artif Organs 2010; 34:778-83. [DOI: 10.1111/j.1525-1594.2010.01107.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
27
|
|
28
|
Yulong Guan, Xiaowei Su, McCoach R, Kunselman A, El-Banayosy A, Ündar A. Mechanical performance comparison between RotaFlow and CentriMag centrifugal blood pumps in an adult ECLS model. Perfusion 2010; 25:71-6. [DOI: 10.1177/0267659110365366] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Introduction: Centrifugal blood pumps have been widely adopted in conventional adult cardiopulmonary bypass and circulatory assist procedures. Different brands of centrifugal blood pumps incorporate distinct designs which affect pump performance. In this adult extracorporeal life support (ECLS) model, the performances of two brands of centrifugal blood pump (RotaFlow blood pump and CentriMag blood pump) were compared. Methods: The simulated adult ECLS circuit used in this study included a centrifugal blood pump, Quadrox D membrane oxygenator and Sorin adult ECLS tubing package. A Sorin Cardiovascular® VVR® 4000i venous reservoir (Sorin S.p.A., Milan, Italy) with a Hoffman clamp served as a pseudo-patient. The circuit was primed with 900ml heparinized human packed red blood cells and 300ml lactated Ringer’s solution (total volume 1200 ml, corrected hematocrit 40%). Trials were conducted at normothermia (36°C). Performance, including circuit pressure and flow rate, was measured for every setting analyzed. Results: The shut-off pressure of the RotaFlow was higher than the CentriMag at all measurement points given the same rotation speed (p < 0.0001). The shut-off pressure differential between the two centrifugal blood pumps was significant and increased given higher rotation speeds (p < 0.0001). The RotaFlow blood pump has higher maximal flow rate (9.08 ± 0.01L/min) compared with the CentriMag blood pump (8.37 ± 0.02L/min) (p < 0.0001). The blood flow rate differential between the two pumps when measured at the same revolutions per minute (RPM) ranged from 1.64L/min to 1.73L/min. Conclusions: The results obtained in this experiment demonstrate that the RotaFlow has a higher shut-off pressure (less retrograde flow) and maximal blood flow rate than the CentriMag blood pump. Findings support the conclusion that the RotaFlow disposable pump head has a better mechanical performance than the CentriMag. In addition, the RotaFlow disposable pump is 20-30 times less expensive than the CentriMag.
Collapse
Affiliation(s)
- Yulong Guan
- Penn State Hershey Pediatric Cardiovascular Research Center, Department of Pediatrics, Penn State College of Medicine, Penn State Children's Hospital, Hershey, Pennsylvania, USA
| | - Xiaowei Su
- Penn State Hershey Pediatric Cardiovascular Research Center, Department of Pediatrics, Penn State College of Medicine, Penn State Children's Hospital, Hershey, Pennsylvania, USA
| | - Robert McCoach
- Penn State Hershey Pediatric Cardiovascular Research Center, Department of Pediatrics, Penn State College of Medicine, Penn State Children's Hospital, Hershey, Pennsylvania, USA
| | - Allen Kunselman
- Public Health Sciences, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital, Hershey, Pennsylvania, USA
| | - Aly El-Banayosy
- Heart and Vascular Institute, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Children's Hospital, Hershey, Pennsylvania, USA
| | - Akif Ündar
- Penn State Hershey Pediatric Cardiovascular Research Center, Department of Pediatrics, Penn State College of Medicine, Penn State Children's Hospital, Hershey, Pennsylvania, USA, Department of Surgery, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Children's Hospital, Hershey, Pennsylvania, USA, Department of Bioengineering, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Children's Hospital, Hershey,
| |
Collapse
|
29
|
Someya T, Kobayashi M, Waguri S, Ushiyama T, Nagaoka E, Hijikata W, Shinshi T, Arai H, Takatani S. Development of a Disposable Maglev Centrifugal Blood Pump Intended for One-Month Support in Bridge-to-Bridge Applications: In Vitro and Initial In Vivo Evaluation. Artif Organs 2009; 33:704-13. [DOI: 10.1111/j.1525-1594.2009.00900.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
30
|
|