Raymond C, Dell'Osso L, Golding C, Zahner C. Cost-Effectiveness and Return on Investment Analysis of an In-house HemosIL Heparin-Induced Thrombocytopenia Antibody Assay at a Mid-Sized Institution. Arch Pathol Lab Med 2024; 148:846-851. [PMID: 37756572 DOI: 10.5858/arpa.2023-0141-oa] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/19/2023] [Indexed: 09/29/2023]
Abstract
CONTEXT.— Laboratories face the challenge of providing quality patient care while managing costs and turnaround times (TATs). To this end, we brought the heparin-induced thrombocytopenia (HIT) antibody test in-house with the goal of reducing costs and the time to diagnosis. OBJECTIVES.— To determine the cost-effectiveness and return on investment of our in-house HIT antibody test by comparing it to send-out assays with TATs of 2, 3, or 4 days. DESIGN.— We performed a retrospective chart review of all patients with a HIT antibody assay and analysis of laboratory financial records. Analysis included the percentage of patients receiving alternative treatment, cost of treatment, startup costs of bringing the test in-house, and average TAT of the in-house test. RESULTS.— We found significant reductions in the cost of treatment for patients and the overall cost to the health care system. The in-house assay became cost-effective at between 8 and 20 tests, with a return on investment of up to 298%. CONCLUSIONS.— Bringing the HIT antibody assay in-house becomes cost-effective at a very low test volume with excellent return on investment. This novel analysis can provide a framework for other laboratory medicine professionals to analyze the benefits of bringing this and other assays in-house.
Collapse
Affiliation(s)
- Caitlin Raymond
- From the Departments of Pathology, University of Texas Medical Branch, Galveston(Raymond, Dell'Osso, Zahner)
| | - Liesel Dell'Osso
- From the Departments of Pathology, University of Texas Medical Branch, Galveston(Raymond, Dell'Osso, Zahner)
| | - Charles Golding
- From the Departments of Pharmacology, University of Texas Medical Branch, Galveston.(Golding)
| | - Christopher Zahner
- From the Departments of Pathology, University of Texas Medical Branch, Galveston(Raymond, Dell'Osso, Zahner)
| |
Collapse
|
2
|
Arachchillage DJ, Thachil J, Anderson JAM, Baker P, Poles A, Kitchen S, Laffan M. Diagnosis and management of heparin-induced thrombocytopenia: Third edition. Br J Haematol 2024; 204:459-475. [PMID: 38153164 DOI: 10.1111/bjh.19180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 10/16/2023] [Accepted: 10/19/2023] [Indexed: 12/29/2023]
Affiliation(s)
- Deepa J Arachchillage
- Centre for Haematology, Department of Immunology and Inflammation, Imperial College London, London, UK
- Department of Haematology, Imperial College Healthcare NHS Trust, London, UK
| | - Jecko Thachil
- Department of Haematology, Manchester Royal Infirmary, Manchester, UK
| | - Julia A M Anderson
- Department of Haematology, Edinburgh Royal Infirmary, Edinburgh, Scotland
| | - Peter Baker
- Oxford Haemophilia and Thrombosis Centre, Oxford University Hospitals NHS Trust, Oxford, UK
| | - Anthony Poles
- Bristol NHS Blood and Transplant Centre, Bristol, UK
| | - Steve Kitchen
- Department of Haematology, Royal Hallamshire Hospital, Sheffield, UK
| | - Mike Laffan
- Centre for Haematology, Department of Immunology and Inflammation, Imperial College London, London, UK
- Department of Haematology, Imperial College Healthcare NHS Trust, London, UK
| |
Collapse
|
3
|
Tucker CM, Rhoades R, Sharma R, Gong JZ. Optimization of laboratory diagnosis of heparin-induced thrombocytopenia using HemosIL-AcuStar-HIT-IgG assay. Lab Med 2024; 55:34-39. [PMID: 37094798 DOI: 10.1093/labmed/lmad029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2023] Open
Abstract
OBJECTIVE The aim of this study was to determine an optimal cutoff value for the newly available HemosIL-AcuStar-HIT-IgG assay (AcuStar) for the diagnosis of heparin-induced thrombocytopenia (HIT). METHOD We evaluated the performance of AcuStar using serotonin release assay (SRA) as the gold standard and incorporated 4T score calculation in a cohort of suspected HIT cases. Statistical analysis was performed to determine optimal cutoff value for the diagnosis of HIT. RESULT A diagnosis of HIT can be excluded with a platelet factor 4 (PF4) value of <0.4 U/mL by AcuStar and 4T score in the low-risk category (≤3). All other cases will require confirmation with a functional test. CONCLUSION Our study resulted in the implementation of a diagnostic algorithm for laboratory diagnosis of HIT, which incorporates pretest calculation of 4T score and AcuStar as a screening test, with reflex confirmation by SRA. This new algorithm resulted in extended hours of test availability and a more rapid turnaround time in reporting PF4 results.
Collapse
Affiliation(s)
- Catherine M Tucker
- Department of Pathology, Anatomy, and Cell Biology, Thomas Jefferson University, Philadelphia, PA, US
| | - Ruben Rhoades
- Department of Medicine, Division of Hematology, Thomas Jefferson University, Philadelphia, PA, US
| | - Ruchika Sharma
- Department of Pediatrics, Division of Hematology/Oncology/BMT, Medical College of Wisconsin, Versiti Blood Research Institute, Milwaukee, WI,US
| | - Jerald Z Gong
- Department of Pathology, Anatomy, and Cell Biology, Thomas Jefferson University, Philadelphia, PA, US
| |
Collapse
|
4
|
Tchen S, Bhatt R, Rezazadeh A, Foy P. Using novel PF4-dependent P-selectin expression assay to diagnose heparin-induced thrombocytopaenia postliver transplantation. BMJ Case Rep 2022; 15:e248269. [PMID: 35680283 PMCID: PMC9185387 DOI: 10.1136/bcr-2021-248269] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/29/2022] [Indexed: 11/03/2022] Open
Abstract
Heparin-induced thrombocytopaenia (HIT) is a well-known adverse event associated with the use of heparin products. HIT may be difficult to diagnose in patients following liver transplantation as patients routinely require massive transfusion support and immunosuppression. As an alternative or adjunctive to the serotonin release assay, the PF4-dependent P-selectin expression assay (PEA) may be a useful diagnostic test in the determination of HIT in this patient population. In this case, we describe a 63-year-old man who had an orthotopic liver transplant that was complicated by HIT that was diagnosed using the PEA.
Collapse
Affiliation(s)
| | - Rootvij Bhatt
- Pharmacy, Froedtert Hospital, Milwaukee, Wisconsin, USA
| | - Alexandra Rezazadeh
- Department of Hematology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Patrick Foy
- Department of Hematology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| |
Collapse
|
5
|
Vercruysse K, Devreese KMJ. Laboratory testing for post ChAdOx1 nCOV-19 vaccination VITT: A challenge. Comment on: Recommendations for the clinical and laboratory diagnosis of VITT against COVID-19: Communication from the ISTH SSC Subcommittee on Platelet Immunology. J Thromb Haemost 2021; 19:2355-2357. [PMID: 34312992 PMCID: PMC8420275 DOI: 10.1111/jth.15457] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Accepted: 07/01/2021] [Indexed: 11/28/2022]
Affiliation(s)
- Kobe Vercruysse
- Coagulation Laboratory, Department of Laboratory Medicine, University Hospital Ghent, Ghent, Belgium
| | - Katrien M J Devreese
- Coagulation Laboratory, Department of Laboratory Medicine, University Hospital Ghent, Ghent, Belgium
- Department of Diagnostic Sciences, Ghent University, Ghent, Belgium
| |
Collapse
|
6
|
Althaus K, Westphal A, Strobel U, Bakchoul T, Greinacher A. Real-life evaluation of an automated immunoassay for diagnosis of heparin-induced thrombocytopenia. Thromb Res 2020; 196:400-403. [DOI: 10.1016/j.thromres.2020.09.032] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 09/06/2020] [Accepted: 09/23/2020] [Indexed: 01/06/2023]
|
7
|
Jousselme E, Guéry EA, Nougier C, Sobas F, Rollin J, Gruel Y, Vayne C, Pouplard C. Prospective evaluation of two specific IgG immunoassays (HemosIL ® AcuStar HIT-IgG and HAT45G ® ) for the diagnosis of heparin-induced thrombocytopenia: A Bayesian approach. Int J Lab Hematol 2020; 43:468-476. [PMID: 33244896 DOI: 10.1111/ijlh.13404] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 09/30/2020] [Accepted: 10/21/2020] [Indexed: 12/11/2022]
Abstract
INTRODUCTION The accurate diagnosis of heparin-induced thrombocytopenia (HIT) is essential to ensure adequate treatment and prevent complications. First step diagnosis test are immunoassays including enzyme-linked immunosorbent assays (ELISAs) and rapid immunoassays. METHODS Using a Bayesian approach, we prospectively evaluated the performance of the IgG PF4/polyvinylsulfonate ELISA and a chemiluminescent immunoassay (CLIA), which are specific for IgG and use the same antigenic target to detect HIT antibodies. RESULTS One hundred and eighty-four 184 consecutive patients with an intermediate (n = 159) or high (n = 25) clinical pretest probability of HIT based on the 4Ts score or platelet pattern were included. Both immunoassays (IAs) were performed on all 184 samples, and definite HIT was confirmed with a positive serotonin release assay in 29 patients (12.7%). The sensitivity (Ss) and negative predictive value (NPV) of ELISA were excellent (100%) allowing HIT to be excluded with good confidence when the test was negative. In addition, the Ss and NPV of the CLIA equalled 93.1% and 98.6%, respectively, as it was negative in two definite HIT. When the CLIA was negative, the post-test probability of HIT was 0.7% in case of intermediate risk. Although there was excellent agreement between CLIA and ELISA results, the quantitative values provided by the two IAs were not correlated. CONCLUSION AcuStar HIT® detects more than 90% of HIT, as do all rapid IAs, and appears to be a good tool for excluding HIT when the pretest probability is intermediate. A chemiluminescent signal higher than 10 IU/mL is highly predictive of definite HIT with a PPV of 100%.
Collapse
Affiliation(s)
- Emilie Jousselme
- Department of Haematology-Haemostasis, Civil Hospices of Lyon, Bron, France
| | - Eve-Anne Guéry
- Department of Haematology-Haemostasis, Regional University Hospital of Tours, Tours, France
| | - Christophe Nougier
- Department of Haematology-Haemostasis, Civil Hospices of Lyon, Bron, France
| | - Frédéric Sobas
- Department of Haematology-Haemostasis, Civil Hospices of Lyon, Bron, France
| | - Jérôme Rollin
- Department of Haematology-Haemostasis, Regional University Hospital of Tours, Tours, France.,EA 7501 GICC, University of Tours, Tours, France
| | - Yves Gruel
- Department of Haematology-Haemostasis, Regional University Hospital of Tours, Tours, France.,EA 7501 GICC, University of Tours, Tours, France
| | - Caroline Vayne
- Department of Haematology-Haemostasis, Regional University Hospital of Tours, Tours, France.,EA 7501 GICC, University of Tours, Tours, France
| | - Claire Pouplard
- Department of Haematology-Haemostasis, Regional University Hospital of Tours, Tours, France.,EA 7501 GICC, University of Tours, Tours, France
| |
Collapse
|
8
|
Favaloro EJ, Mohammed S, Donikian D, Kondo M, Duncan E, Yacoub O, Zebeljan D, Ng S, Malan E, Yuen A, Beggs J, Moosavi S, Coleman R, Klose N, Chapman K, Cavanaugh L, Pasalic L, Motum P, Tan CW, Brighton T. A multicentre assessment of contemporary laboratory assays for heparin induced thrombocytopenia. Pathology 2020; 53:247-256. [PMID: 33032809 DOI: 10.1016/j.pathol.2020.07.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Revised: 06/25/2020] [Accepted: 07/23/2020] [Indexed: 12/27/2022]
Abstract
Heparin induced thrombocytopenia (HIT) is a rare but potentially fatal complication of heparin therapy. In some patients, HIT causes platelet activation and thrombosis (sometimes abbreviated HITT), which leads to adverse clinical sequalae ('pathological HIT'). The likelihood of HIT is initially assessed clinically, typically using a scoring system, of which the 4T score is that most utilised. Subsequent laboratory testing to confirm or exclude HIT facilitates exclusion or diagnosis and management. The current investigation comprises a multicentre (n=9) assessment of contemporary laboratory testing for HIT, as performed over the past 1-3 years in each site and comprising testing of over 1200 samples. The primary laboratory test used by study participants (n=8) comprised a chemiluminescence procedure (HIT-IgG(PF4-H)) performed on an AcuStar instrument. Additional immunological testing performed by study sites included lateral flow (STiC, Stago), enzyme linked immunosorbent assay (ELISA), Asserachrom (HPIA IgG), PaGIA (BioRad), plus functional assays, primarily serotonin release assay (SRA) or platelet aggregation methods. The chemiluminescence procedure yielded a highly sensitive screening method for identifying functional HIT, given high area under the curve (AUC, generally ≥0.9) in a receiver operator characteristic (ROC) analysis against SRA as gold standard. ELISA testing resulted in lower ROC AUC scores (<0.8) and higher levels of false positives. Although there is clear association with the likelihood of HIT, the 4T score had less utility than literature suggests, and was comparable to a previous study reported by some of the authors.
Collapse
Affiliation(s)
- Emmanuel J Favaloro
- Department of Haematology, Institute of Clinical Pathology and Medical Research (ICPMR), Sydney Centres for Thrombosis and Haemostasis, Westmead Hospital, Westmead, NSW, Australia; NSW Health Pathology, NSW, Australia; School of Biomedical Sciences, Charles Sturt University, Wagga Wagga, NSW, Australia.
| | - Soma Mohammed
- Department of Haematology, Institute of Clinical Pathology and Medical Research (ICPMR), Sydney Centres for Thrombosis and Haemostasis, Westmead Hospital, Westmead, NSW, Australia; NSW Health Pathology, NSW, Australia
| | - Dea Donikian
- NSW Health Pathology, NSW, Australia; Prince of Wales Hospital, Randwick, NSW, Australia
| | - Mayuko Kondo
- NSW Health Pathology, NSW, Australia; Prince of Wales Hospital, Randwick, NSW, Australia
| | | | | | - Diane Zebeljan
- NSW Health Pathology, NSW, Australia; Liverpool Hospital, Liverpool, NSW, Australia
| | - Sara Ng
- NSW Health Pathology, NSW, Australia; Liverpool Hospital, Liverpool, NSW, Australia
| | | | - Agnes Yuen
- Monash Health, Melbourne, Vic, Australia
| | | | | | - Robyn Coleman
- Sullivan Nicolaides Pathology, Brisbane, Qld, Australia
| | - Nathan Klose
- Sullivan Nicolaides Pathology, Brisbane, Qld, Australia
| | - Kent Chapman
- NSW Health Pathology, NSW, Australia; John Hunter Hospital, Newcastle, NSW, Australia
| | - Lauren Cavanaugh
- NSW Health Pathology, NSW, Australia; St George Hospital, Kogarah, NSW, Australia
| | - Leonardo Pasalic
- Department of Haematology, Institute of Clinical Pathology and Medical Research (ICPMR), Sydney Centres for Thrombosis and Haemostasis, Westmead Hospital, Westmead, NSW, Australia; NSW Health Pathology, NSW, Australia; School of Biomedical Sciences, Charles Sturt University, Wagga Wagga, NSW, Australia
| | - Penelope Motum
- NSW Health Pathology, NSW, Australia; Liverpool Hospital, Liverpool, NSW, Australia
| | - Chee Wee Tan
- South Australia Pathology, Adelaide, SA, Australia; Royal Adelaide Hospital, Adelaide, SA, Australia
| | - Timothy Brighton
- NSW Health Pathology, NSW, Australia; Prince of Wales Hospital, Randwick, NSW, Australia
| |
Collapse
|
9
|
HIT or miss? A comprehensive contemporary investigation of laboratory tests for heparin induced thrombocytopenia. Pathology 2018; 50:426-436. [DOI: 10.1016/j.pathol.2017.11.089] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2017] [Revised: 11/16/2017] [Accepted: 11/21/2017] [Indexed: 11/17/2022]
|
10
|
Nagler M, Bakchoul T. Clinical and laboratory tests for the diagnosis of heparin-induced thrombocytopenia. Thromb Haemost 2017; 116:823-834. [DOI: 10.1160/th16-03-0240] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2016] [Accepted: 08/16/2016] [Indexed: 12/27/2022]
Abstract
SummaryA rapid diagnostic work-up is required in patients with suspected heparin-induced thrombocytopenia (HIT). However, diagnosis of HIT is challenging due to a number of practical issues and methodological limitations. Many laboratory tests and a few clinical scoring systems are available but the individual characteristics and the diagnostic accuracy of these are hard to appraise. The 4Ts score is a well evaluated clinical assessment tool with the potential to rule out HIT in many patients. Still, it requires experience and is subject to a relevant inter-observer variability. Immunoassays such as enzyme-linked immunosorbent assays or recently developed rapid assays are able to exclude HIT in a number of patients. But, accuracy of immunoassays differs depending on type of assay, threshold, antibody specificity and even manufacturer. Due to a comparatively low positive predictive value, HIT cannot be confirmed by immunoassays alone. In addition, only some of them are immediately accessible, particularly in small laboratories. While functional assays such as the serotonin release assay (SRA) and the heparin-induced platelet activation assay (HIPA) are considered as gold standard for diagnosis of HIT, they require a highly specialised laboratory. In addition, some of them are not adequately evaluated. In clinical practice, we recommend an integrated diagnostic approach combining not only clinical assessment (the 4Ts score) but immunoassays and functional assays as well. We propose a clear diagnostic algorithm supporting clinical decision-making. Furthermore, we provide an overview of all current laboratory techniques for HIT and discuss diagnostic pathways and strategies to reduce diagnostic errors, and future perspectives.
Collapse
|
11
|
Rapid immunoassays for diagnosis of heparin-induced thrombocytopenia: Comparison of diagnostic accuracy, reproducibility, and costs in clinical practice. PLoS One 2017; 12:e0178289. [PMID: 28594835 PMCID: PMC5464550 DOI: 10.1371/journal.pone.0178289] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Accepted: 05/10/2017] [Indexed: 01/01/2023] Open
Abstract
Background Immunoassays are crucial in the work-up of patients with suspected heparin-induced thrombocytopenia (HIT) and rapid tests have been recently developed. However, comparative data on diagnostic accuracy, reproducibility, and analytical costs of different immunoassays in clinical practice are limited. Methods Samples of 179 consecutive patients evaluated for suspected HIT in clinical practice using a polyspecific enzyme-linked immunoabsorbent assay (GTI diagnostics; ELISA) and a rapid particle gel immunoassay (PaGIA), were additionally analysed with a IgG-specific chemiluminescent immunoassay (AcuStar HIT-IgG). Presence of HIT was defined as a positive functional heparin-induced platelet aggregation test. Diagnostic accuracy was determined for low, intermediate and high thresholds as previously established (ELISA: optical density 0.4, 1.3, and 2.0 respectively; PaGIA: positive/negative, titre of 4, titre of 32; AcuStar HIT-IgG: 1.0 U/ml, 2.8, 9.4) and reproducibility was assessed by repeated measurements. Costs of test determination were calculated taking reagents, controls, and working time of technicians according to Swiss health care system into account. Results Data on PaGIA results were available for 171 patients (95.5%), ELISA for 144 patients (80.4%), and AcuStar HIT-IgG for 179 patients (100%). Sensitivity was above 95% for all assays at low and intermediate thresholds. Specificity increased with higher thresholds and was above 90% for all assays with intermediate and high thresholds. Specificity of AcuStar HIT-IgG (92.8%; 95% CI 87.7, 96.2) was significantly higher than PaGIA (83.0%; 95% CI 76.3, 88.5) and higher than ELISA (81.8%, 95% CI 74.2, 88.0) at low threshold (p<0.05). Reproducibility was adequate for all assays. Total costs per test were CHF 51.02 for ELISA, 117.70 for AcuStar HIT-IgG, and 83.13 for PaGIA. Conclusions We observed favourable diagnostic accuracy measures and a high reproducibility for PaGIA and AcuStar HIT-IgG. Implementation into 24-hours-service might improve patient care but the results must be confirmed in other settings and larger populations as well.
Collapse
|
12
|
Husseinzadeh HD, Gimotty PA, Pishko AM, Buckley M, Warkentin TE, Cuker A. Diagnostic accuracy of IgG-specific versus polyspecific enzyme-linked immunoassays in heparin-induced thrombocytopenia: a systematic review and meta-analysis. J Thromb Haemost 2017; 15:1203-1212. [PMID: 28374939 PMCID: PMC6039095 DOI: 10.1111/jth.13692] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Indexed: 12/17/2022]
Abstract
Essentials Immunoassay specificity varies in heparin-induced thrombocytopenia (HIT) testing. This meta-analysis examined 9 studies that tested samples by both IgG and polyspecific methods. IgG-specific assays confer superior diagnostic accuracy compared with polyspecific assays. These results further support recommendations in favor of IgG-specific testing. SUMMARY Background There are conflicting data on whether the IgG-specific or polyspecific antiplatelet factor 4/heparin (PF4/H) enzyme-linked immunosorbent assay (ELISA) is preferred for the laboratory diagnosis of heparin-induced thrombocytopenia (HIT). Objectives To directly compare diagnostic accuracy of IgG-specific versus polyspecific ELISA in HIT. Patients/Methods A systematic search yielded nine studies comprising 1948 patients with suspected HIT tested by both IgG-specific and polyspecific ELISAs and a reference standard against which the diagnostic accuracy of the ELISAs could be measured. Study quality was assessed by QUADAS-2 criteria. Results There was identical sensitivity for IgG-specific and polyspecific ELISAs (0.97; 95% confidence interval (CI), 0.95-0.99) and superior specificity of IgG-specific compared with polyspecific ELISA (0.87 [0.85-0.88] vs. 0.82 [0.80-0.84], respectively). Performance was similar in subgroups using the serotonin release assay and a single commercial ELISA manufacturer. The negative predictive values of IgG-specific and polyspecific ELISA were similarly high (0.99, [0.99-1.00], but the positive predictive value was superior with IgG-specific compared with polyspecific ELISA (0.56 [0.52-0.61] vs. 0.32 [0.28-0.35], respectively). The positive likelihood ratio (LR) was higher in IgG-specific than polyspecific ELISA, although negative LRs were similar. There was high risk of quality concerns in domains of index test and reference standard. Conclusions The superior diagnostic accuracy of IgG-specific ELISA reinforces the ISTH-SSC recommendation for standardization of laboratory testing for HIT. Likelihood ratios of individual assays may be used in combination with clinical scoring systems as part of an integrated diagnostic algorithm for HIT.
Collapse
Affiliation(s)
- H D Husseinzadeh
- Department of Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - P A Gimotty
- Department of Biostatistics and Epidemiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - A M Pishko
- Department of Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - M Buckley
- Department of Biostatistics and Epidemiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - T E Warkentin
- Departments of Pathology and Molecular Medicine, and Medicine, Michael G. DeGroote School of Medicine, McMaster University, Hamilton, ON, Canada
| | - A Cuker
- Department of Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
- Department of Pathology and Laboratory Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
13
|
Wang X, Jiang C, Qin Y, Peng Y, Wen G, Liang A, Jiang Z. SERS spectral study of HAuCl 4-cysteine nanocatalytic reaction and its application for detection of heparin sodium with label-free VB4r molecular probe. Sci Rep 2017; 7:45979. [PMID: 28378828 PMCID: PMC5380991 DOI: 10.1038/srep45979] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Accepted: 03/07/2017] [Indexed: 12/23/2022] Open
Abstract
In the presence of nanocatalyst, L-cysteine reduce HAuCl4 rapidly to form gold nanoparticles (AuNP), and a quick nanocatalytic preparation procedure was established for Au/AuNP sol with highly active surface enhanced Raman scattering (SERS) effect and good stability. The nanoreaction was also studied by absorption, resonance Rayleigh scattering (RRS), transmission electron microscopy (TEM) and energy spectra. In the selected conditions, the analyte heparin sodium (HS) could react with victoria blue 4 R (VB4r) to form associated complexes which have very weak SERS effect to make the SERS signals decrease. The SERS signals at 1617 cm−1 reduced linearly with HS concentration increasing. Upon addition of FeCl3, it hydrolyzed to form stable Fe(OH)3 sol platform that carried SERS active Au/AuNPs to enhance the sensitivity. Accordingly, we established a SERS quantitative analysis method in the sol substrate of Fe(OH)3-Au/AuNPs, with a linear range of 0.5–75 ng/mL HS and a detection limit of 0.2 ng/mL. HS in real samples was determined, with a relative standard deviation of 2.65–7.63% and a recovery of 99.3–101%.
Collapse
Affiliation(s)
- Xiaoliang Wang
- Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection of Ministry Education, Guangxi Key Laboratory of Environmental Pollution Control Theory and Technology, Guangxi Normal University, Guilin 541004, China
| | - Caina Jiang
- Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection of Ministry Education, Guangxi Key Laboratory of Environmental Pollution Control Theory and Technology, Guangxi Normal University, Guilin 541004, China
| | - Yanna Qin
- Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection of Ministry Education, Guangxi Key Laboratory of Environmental Pollution Control Theory and Technology, Guangxi Normal University, Guilin 541004, China
| | - Yutao Peng
- Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection of Ministry Education, Guangxi Key Laboratory of Environmental Pollution Control Theory and Technology, Guangxi Normal University, Guilin 541004, China
| | - Guiqing Wen
- Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection of Ministry Education, Guangxi Key Laboratory of Environmental Pollution Control Theory and Technology, Guangxi Normal University, Guilin 541004, China
| | - Aihui Liang
- Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection of Ministry Education, Guangxi Key Laboratory of Environmental Pollution Control Theory and Technology, Guangxi Normal University, Guilin 541004, China
| | - Zhiliang Jiang
- Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection of Ministry Education, Guangxi Key Laboratory of Environmental Pollution Control Theory and Technology, Guangxi Normal University, Guilin 541004, China
| |
Collapse
|
14
|
Nagler M, Cuker A. Profile of Instrumentation Laboratory's HemosIL® AcuStar HIT-Ab(PF4-H) assay for diagnosis of heparin-induced thrombocytopenia. Expert Rev Mol Diagn 2017; 17:419-426. [PMID: 28271738 DOI: 10.1080/14737159.2017.1304213] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Immunoassays play an essential role in the diagnosis of heparin-induced thrombocytopenia (HIT). The objective of this article is to review HemosIL® AcuStar HIT-Ab(PF4-H) (Instrumentation Laboratory, Bedford, MA, USA), a new chemiluminescent immunoassay for HIT. Areas covered: The authors searched the published literature for evaluation studies of HemosIL® AcuStar HIT-Ab(PF4-H) and sought information from the manufacturer. In this paper, the authors discuss the analytical principle and technical aspects of the assay; describe its diagnostic performance in validation studies; report on its reproducibility, cost-effectiveness, and regulatory status; and discuss the implications of the assay on clinical practice and means of integrating it in diagnostic pathways. HemosIL® AcuStar HIT-Ab(PF4-H) is compared with other rapid assays and widely used enzyme-linked immunoassays for the diagnosis of HIT. Expert commentary: HemosIL® AcuStar HIT-Ab(PF4-H) is automatable, can be performed 24 h per day, offers a rapid turnaround time, and appears to have favorable diagnostic accuracy, particularly at thresholds above that listed in the label. These advantages could lead to improved patient outcomes through rapid provision of results at the point of care, enhancing the accuracy of initial diagnosis.
Collapse
Affiliation(s)
- Michael Nagler
- a Department of Haematology and Central Haematology Laboratory , University of Bern , Bern , Switzerland
| | - Adam Cuker
- b Departments of Medicine and Pathology & Laboratory Medicine , University of Pennsylvania , Philadelphia , PA , USA
| |
Collapse
|
15
|
Sun L, Gimotty PA, Lakshmanan S, Cuker A. Diagnostic accuracy of rapid immunoassays for heparin-induced thrombocytopenia. A systematic review and meta-analysis. Thromb Haemost 2016; 115:1044-55. [PMID: 26763074 DOI: 10.1160/th15-06-0523] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2015] [Accepted: 12/03/2015] [Indexed: 01/15/2023]
Abstract
The platelet factor 4/heparin ELISA has limited specificity for heparin-induced thrombocytopenia (HIT) and frequently does not provide same-day results. Rapid immunoassays (RIs) have been developed which provide results in 30 minutes or less. We conducted a systematic review and meta-analysis to evaluate the diagnostic accuracy of RIs for HIT. We searched the literature for studies in which samples from patients with suspected HIT were tested using a RI and a functional assay against which the performance of the RI could be measured. We performed sensitivity analyses of studies that directly compared different RIs with each other and with ELISAs. Estimates of sensitivity and specificity for each RI were calculated. Twenty-three articles, collectively involving six different RIs, met eligibility criteria. All RIs exhibited high sensitivity (0.96 to 1.00); there was wider variability in specificity (0.68 to 0.94). Specificity of the IgG-specific chemiluminescent assay (IgG-CA) was greater than the polyspecific chemiluminescent assay [0.94 (95 %CI 0.89-0.99) vs 0.82 (0.77-0.87)]. The particle gel immunoassay demonstrated greater specificity than the polyspecific ELISA [0.96 (0.95-0.97) vs 0.91 (0.89-0.92)]. The IgG-CA and lateral flow immunoassay [0.94 (0.91-0.97)] exhibited greater specificity than the IgG-specific ELISA [0.86 (0.82-0.90)]. Given their high sensitivity and rapid turnaround time, RIs are a reliable means of excluding HIT at the point-of-care in patients with low or intermediate clinical probability. Additionally, some RIs have greater specificity than HIT ELISAs. In summary, IgG-specific RIs appear to have improved diagnostic accuracy compared with ELISAs in patients with suspected HIT and may reduce misdiagnosis and overtreatment.
Collapse
Affiliation(s)
| | | | | | - Adam Cuker
- Adam Cuker, MD, MS, Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA, Tel.: +1 215 615 6555, Fax: +1 215 615 6599, E-mail:
| |
Collapse
|
16
|
Diagnostic value of immunoassays for heparin-induced thrombocytopenia: a systematic review and meta-analysis. Blood 2015; 127:546-57. [PMID: 26518436 DOI: 10.1182/blood-2015-07-661215] [Citation(s) in RCA: 104] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2015] [Accepted: 10/27/2015] [Indexed: 01/20/2023] Open
Abstract
Immunoassays are essential in the workup of patients with suspected heparin-induced thrombocytopenia. However, the diagnostic accuracy is uncertain with regard to different classes of assays, antibody specificities, thresholds, test variations, and manufacturers. We aimed to assess diagnostic accuracy measures of available immunoassays and to explore sources of heterogeneity. We performed comprehensive literature searches and applied strict inclusion criteria. Finally, 49 publications comprising 128 test evaluations in 15 199 patients were included in the analysis. Methodological quality according to the revised tool for quality assessment of diagnostic accuracy studies was moderate. Diagnostic accuracy measures were calculated with the unified model (comprising a bivariate random-effects model and a hierarchical summary receiver operating characteristics model). Important differences were observed between classes of immunoassays, type of antibody specificity, thresholds, application of confirmation step, and manufacturers. Combination of high sensitivity (>95%) and high specificity (>90%) was found in 5 tests only: polyspecific enzyme-linked immunosorbent assay (ELISA) with intermediate threshold (Genetic Testing Institute, Asserachrom), particle gel immunoassay, lateral flow immunoassay, polyspecific chemiluminescent immunoassay (CLIA) with a high threshold, and immunoglobulin G (IgG)-specific CLIA with low threshold. Borderline results (sensitivity, 99.6%; specificity, 89.9%) were observed for IgG-specific Genetic Testing Institute-ELISA with low threshold. Diagnostic accuracy appears to be inadequate in tests with high thresholds (ELISA; IgG-specific CLIA), combination of IgG specificity and intermediate thresholds (ELISA, CLIA), high-dose heparin confirmation step (ELISA), and particle immunofiltration assay. When making treatment decisions, clinicians should be a aware of diagnostic characteristics of the tests used and it is recommended they estimate posttest probabilities according to likelihood ratios as well as pretest probabilities using clinical scoring tools.
Collapse
|
17
|
Park JH, Kim JE, Kim HK, Han KS. Presence of Antiheparin/Platelet Factor 4 Immunoglobulin G Is Associated With Poor Prognosis in Patients With Suspected Disseminated Intravascular Coagulation. Clin Appl Thromb Hemost 2015; 21:66-71. [DOI: 10.1177/1076029613489596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The underlying inflammatory or infectious condition in disseminated intravascular coagulation (DIC) may stimulate the formation of antiheparin/platelet factor 4 (PF4) antibody, and the resulting antibody may affect the clinical course of DIC. We investigated the prognosis of antiheparin/PF4 antibodies in patients with suspected DIC. We measured heparin/PF4 immunoglobulin G (IgG) and total antibody levels using an automated chemiluminescence system in 118 patients with DIC. Of the 118 patients, 13 (11.0%) patients were positive for total antiheparin/PF4, and 6 (5.1%) patients were positive for antiheparin/PF4 IgG. These 13 patients were negative for platelet-activating antibody and had low-heparin-induced thrombocytopenia probability scores. Patients with antiheparin/PF4 IgG were older and had lower antithrombin levels than patients without antiheparin/PF4 IgG. Patients with antiheparin/PF4 IgG had a higher risk of mortality than those without antiheparin/PF4 IgG. The presence of antiheparin/PF4 IgG in old age or low antithrombin level patients with DIC with old age or low antithrombin level suggests a poor prognosis.
Collapse
Affiliation(s)
- Jae Hyeon Park
- Department of Laboratory Medicine, Seoul National University College of Medicine, Seoul, Korea
| | - Ji-Eun Kim
- Department of Laboratory Medicine, Seoul National University College of Medicine, Seoul, Korea
- Cancer Research Institute, Seoul National University College of Medicine, Seoul, Korea
| | - Hyun Kyung Kim
- Department of Laboratory Medicine, Seoul National University College of Medicine, Seoul, Korea
- Cancer Research Institute, Seoul National University College of Medicine, Seoul, Korea
| | - Kyou Sup Han
- Department of Laboratory Medicine, Seoul National University College of Medicine, Seoul, Korea
| |
Collapse
|
18
|
Jourdy Y, Nougier C, Rugeri L, Bordet JC, Sobas F, Negrier C. Prospective evaluation of automatized PF4/heparin immunoassays HemosIL HIT-ab (PF4-H) for the diagnosis of heparin-induced thrombocytopenia. Int J Lab Hematol 2014; 37:244-52. [DOI: 10.1111/ijlh.12275] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2014] [Accepted: 06/16/2014] [Indexed: 11/28/2022]
Affiliation(s)
- Y. Jourdy
- Hemostasis Laboratory; Edouard Herriot Hospital; Lyon France
| | - C. Nougier
- Hemostasis Laboratory; Edouard Herriot Hospital; Lyon France
| | - L. Rugeri
- Hemostasis Laboratory; Edouard Herriot Hospital; Lyon France
| | - J. C. Bordet
- Hemostasis Laboratory; Edouard Herriot Hospital; Lyon France
| | - F. Sobas
- Hemostasis Laboratory; Edouard Herriot Hospital; Lyon France
| | - C. Negrier
- Hemostasis Laboratory; Edouard Herriot Hospital; Lyon France
| |
Collapse
|
19
|
Gruel Y, Rollin J, Leroux D, Pouplard C. Les thrombocytopénies induites par l’héparine : données récentes. Rev Med Interne 2014; 35:174-82. [DOI: 10.1016/j.revmed.2013.04.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2013] [Revised: 04/23/2013] [Accepted: 04/27/2013] [Indexed: 01/08/2023]
|
20
|
Lakos G. Analytical Detection Capabilities of Immunoassay-Based Antiphospholipid Antibody Tests: Do They Matter? Drug Dev Res 2013. [DOI: 10.1002/ddr.21117] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
21
|
Assessment of the performances of AcuStar HIT and the combination with heparin-induced multiple electrode aggregometry: A retrospective study. Thromb Res 2013; 132:352-9. [DOI: 10.1016/j.thromres.2013.06.004] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Revised: 06/03/2013] [Accepted: 06/04/2013] [Indexed: 11/21/2022]
|
22
|
Althaus K, Hron G, Strobel U, Abbate R, Rogolino A, Davidson S, Greinacher A, Bakchoul T. Evaluation of automated immunoassays in the diagnosis of heparin induced thrombocytopenia. Thromb Res 2013; 131:e85-90. [DOI: 10.1016/j.thromres.2013.01.005] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2012] [Revised: 12/10/2012] [Accepted: 01/02/2013] [Indexed: 10/27/2022]
|