1
|
Joshi A, Basukala B, Bista R, Sharma R, Singh N, Pradhan I. Medial Meniscus Repair Using "AJStitch": A Cost-Effective All-Inside All-Suture Meniscal Repair System. Arthrosc Tech 2024; 13:103106. [PMID: 39711901 PMCID: PMC11662861 DOI: 10.1016/j.eats.2024.103106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Accepted: 05/05/2024] [Indexed: 12/24/2024] Open
Abstract
All-inside techniques are based on devices that use PEEK (polyether ether ketone) or biocomposite anchors placed at extracapsular locations such as anchorage points over which the sutures are tied. However, because of complications like irritability and intra-articular migration of these hard anchors, suture-based all-inside meniscal repair systems are now gaining popularity. Although these devices have advantages over conventional all-inside devices, they are costly, thus limiting their widespread use. The AJStitch meniscus repair system uses a specially designed spear to insert all-suture anchors, which can be made using a No. 5 Netbond and 2-0 Ultranet. This Technical Note describes the use of this system. It is an all-inside, all-suture meniscus repair system that provides a locally made, cost-effective option for posterior horn medial meniscus repair.
Collapse
Affiliation(s)
- Amit Joshi
- AKB Center for Arthroscopy, Sports Injuries and Regenerative Medicine. B&B Hospital, Gwarko, Lalitpur, Nepal
| | - Bibek Basukala
- AKB Center for Arthroscopy, Sports Injuries and Regenerative Medicine. B&B Hospital, Gwarko, Lalitpur, Nepal
| | - Rohit Bista
- AKB Center for Arthroscopy, Sports Injuries and Regenerative Medicine. B&B Hospital, Gwarko, Lalitpur, Nepal
| | - Rajiv Sharma
- AKB Center for Arthroscopy, Sports Injuries and Regenerative Medicine. B&B Hospital, Gwarko, Lalitpur, Nepal
| | - Nagmani Singh
- AKB Center for Arthroscopy, Sports Injuries and Regenerative Medicine. B&B Hospital, Gwarko, Lalitpur, Nepal
| | - Ishor Pradhan
- AKB Center for Arthroscopy, Sports Injuries and Regenerative Medicine. B&B Hospital, Gwarko, Lalitpur, Nepal
| |
Collapse
|
2
|
Long Y, Zhang Z, Zhou M, Hou J, Zhou Y, Jiang L, Xu X, Yang R. LARAI portal provides a safe method for lateral meniscus repair: three-dimensional computed tomography and cadaveric assessment. J Orthop Traumatol 2023; 24:53. [PMID: 37775551 PMCID: PMC10541373 DOI: 10.1186/s10195-023-00727-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Accepted: 08/09/2023] [Indexed: 10/01/2023] Open
Abstract
BACKGROUND Lateral, All-Round and All-Inside (LARAI) portal is a viewing or working portal for observing and repairing the lesions of the lateral meniscus. However, there are safety concerns about popliteal artery (PA) injuries during the procedure. This study aimed to assess the safe distance between the trajectory of the LARAI portal and PA. MATERIALS AND METHODS Both three-dimensional computed tomography (3D-CT) and cadavers were used to simulate the LARAI portal trajectory. In the 3D-CT study, between January 2020 and September 2020, 45 participants who underwent computed tomography angiography were included in the study. The shortest distance from the PA to the simulated trajectory needle (PS) was measured using 3D-CT. Mean -3SD -2 was calculated to assess the safety of the LARAI portal trajectory. If this value was more than zero, the trajectory was considered "safe." In the cadaveric study, lower limbs from seven fresh-frozen cadavers were used to establish the "safe" trajectories of the LARAI portal, and the PS was measured. RESULTS In the 3D-CT study, the longest PS (P < 0.001) was found 20 mm lateral to the edge of the patellar tendon trajectory at 0 mm from the posterior cruciate ligament (PCL). Safe trajectories were also found 10 mm, 15 mm, and 20 mm lateral to the edge of the patellar tendon at 0 mm from the PCL, as well as the 20 mm lateral to the edge of the patellar tendon at 3 mm from the PCL. The cadaveric study showed that the average PS of all safe trajectories closely adjoined to PCL was greater than 14 mm. CONCLUSIONS The LARAI portal trajectory in the "figure of four" is safe, and the optimal insertion point is 10-20 mm lateral to the edge of the patellar tendon and closely adjoined to the posterolateral margin of the PCL at knee joint line level. LEVEL OF EVIDENCE Level IV.
Collapse
Affiliation(s)
- Yi Long
- Department of Orthopedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, 107 Yan Jiang Road West, Guangzhou, 510120, Guangdong, China
| | - Zhengzheng Zhang
- Department of Orthopedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, 107 Yan Jiang Road West, Guangzhou, 510120, Guangdong, China
| | - Min Zhou
- Department of Orthopedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, 107 Yan Jiang Road West, Guangzhou, 510120, Guangdong, China
| | - Jingyi Hou
- Department of Orthopedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, 107 Yan Jiang Road West, Guangzhou, 510120, Guangdong, China
| | - Yunfeng Zhou
- Department of Orthopedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, 107 Yan Jiang Road West, Guangzhou, 510120, Guangdong, China
| | - Liang Jiang
- Department of Orthopedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, 107 Yan Jiang Road West, Guangzhou, 510120, Guangdong, China
| | - Xiaoding Xu
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, 107 Yan Jiang Road West, Guangzhou, 510120, Guangdong, China.
| | - Rui Yang
- Department of Orthopedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, 107 Yan Jiang Road West, Guangzhou, 510120, Guangdong, China.
| |
Collapse
|
3
|
Ouanezar H, Blakeney WG, Latrobe C, Saithna A, Fernandes LR, Delaloye JR, Thaunat M, Sonnery-Cottet B. The popliteus tendon provides a safe and reliable location for all-inside meniscal repair device placement. Knee Surg Sports Traumatol Arthrosc 2018; 26:3611-3619. [PMID: 29502169 DOI: 10.1007/s00167-018-4889-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2017] [Accepted: 02/28/2018] [Indexed: 12/22/2022]
Abstract
PURPOSE Repairs of the posterior horn of the lateral meniscus can be technically challenging. In contrast to medial meniscus repairs, the capsule around the posterior segment attachment of the lateral meniscus is quite thin. This study evaluates the clinical results of an arthroscopic all-inside repair technique for unstable, vertical, lateral meniscus tears, using a suture repair placed directly into the popliteus tendon. METHODS A retrospective analysis of prospectively collected data from the SANTI database was performed. All patients who had undergone combined ACL reconstruction with lateral meniscus all-inside repair, using sutures placed in the popliteus tendon, between 2011 and 2015, were included. Patients were reviewed clinically at 1 and 2 years' follow-up. At final follow-up, all patients were contacted to identify if they underwent further surgery or had knee pain, locking or effusion. Symptomatic patients were recalled for clinical evaluation by a physician and Magnetic Resonance Imaging of the knee. Operative notes for those undergoing further surgery were reviewed and rates and type of re-operation, including for failed lateral meniscal repair were recorded. RESULTS Two hundred patients (mean age 28.6 ± 10.2 years) with a mean follow-up of 45.5 ± 12.8 months (range 24.7-75.2) were included. The mean Subjective International Knee Documentation Committee (IKDC) at final follow-up was 85.0 ± 11.3. The post-operative mean side-to-side laxity measured at 1 year was 0.6 ± 1.0 mm. Twenty-six patients underwent re-operation (13%) at a mean follow-up of 14.8 ± 7.8 months. The ACL graft rupture rate was 5.0%. Other causes for re-operation included medial meniscus tear (2.5%), cyclops lesion (1.5%) and septic arthritis (0.5%). The lateral meniscus repair failure rate was 3.5%. No specific complications relating to placement of sutures in the popliteus tendon were identified. CONCLUSION Arthroscopic all-inside repair of unstable, vertical, lateral meniscus tears using a suture placed in the popliteus tendon is a safe technique. It is associated with a very low failure rate with no specific complications. LEVEL OF EVIDENCE Level IV.
Collapse
Affiliation(s)
- Hervé Ouanezar
- Centre Orthopédique Santy, FIFA Medical Center of Excellence, Ramsay-Générale de Santé, Hôpital Privé Jean Mermoz, 24 Avenue Paul Santy, 69008, Lyon, France
| | - William G Blakeney
- Centre Orthopédique Santy, FIFA Medical Center of Excellence, Ramsay-Générale de Santé, Hôpital Privé Jean Mermoz, 24 Avenue Paul Santy, 69008, Lyon, France
| | - Charles Latrobe
- Centre Orthopédique Santy, FIFA Medical Center of Excellence, Ramsay-Générale de Santé, Hôpital Privé Jean Mermoz, 24 Avenue Paul Santy, 69008, Lyon, France
| | - Adnan Saithna
- Department of Orthopaedic Surgery, Southport and Ormskirk Hospital, Southport, UK
| | - Levi Reina Fernandes
- Centre Orthopédique Santy, FIFA Medical Center of Excellence, Ramsay-Générale de Santé, Hôpital Privé Jean Mermoz, 24 Avenue Paul Santy, 69008, Lyon, France
| | - Jean Romain Delaloye
- Centre Orthopédique Santy, FIFA Medical Center of Excellence, Ramsay-Générale de Santé, Hôpital Privé Jean Mermoz, 24 Avenue Paul Santy, 69008, Lyon, France
| | - Mathieu Thaunat
- Centre Orthopédique Santy, FIFA Medical Center of Excellence, Ramsay-Générale de Santé, Hôpital Privé Jean Mermoz, 24 Avenue Paul Santy, 69008, Lyon, France
| | - Bertrand Sonnery-Cottet
- Centre Orthopédique Santy, FIFA Medical Center of Excellence, Ramsay-Générale de Santé, Hôpital Privé Jean Mermoz, 24 Avenue Paul Santy, 69008, Lyon, France.
| |
Collapse
|
4
|
Nishimura A, Fukuda A, Kato K, Fujisawa K, Uchida A, Sudo A. Vascular safety during arthroscopic all-inside meniscus suture. Knee Surg Sports Traumatol Arthrosc 2015; 23:975-80. [PMID: 24253374 DOI: 10.1007/s00167-013-2774-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2013] [Accepted: 10/28/2013] [Indexed: 10/26/2022]
Abstract
PURPOSE The purpose of the study is to assess the orientation and distance of the popliteal artery (PA) from both the anteromedial and anterolateral portals. METHODS The records of 97 patients (100 knees) who underwent knee arthroscopy were reviewed. The shortest distance from the posterior tibial cortex to the PA on the lines from both the medial and lateral borders of the patellar tendon to the PA was evaluated by magnetic resonance imaging at full knee extension. The figure-of-four position was compared between patients with intact and deficient anterior cruciate ligaments (ACLs). The shortest distances from the posterior cruciate ligament (PCL) to the lines running from the medial and lateral borders of the patellar tendon to the PA were also measured. RESULTS The shortest distances from the posterior tibial cortex to the PA were significantly longer in the figure-of-four position than at full knee extension and during extension in the ACL-deficient than intact group. Distances did not significantly differ in the figure-of-four position. The PA was hidden from the anteromedial portal by the PCL, but remained vulnerable from the anterolateral portal. CONCLUSIONS All-inside meniscus suturing of the posterior horn of the lateral meniscus inserted through the anteromedial portal is safer when the knee is in the figure-of-four position than fully extended. Meniscus repairs should be completed before ACL reconstruction due to vascular positions and the ease of approach. LEVEL OF EVIDENCE Prospective correlation study, Level IV.
Collapse
Affiliation(s)
- Akinobu Nishimura
- Department of Orthopaedic and Sports Medicine, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan,
| | | | | | | | | | | |
Collapse
|