1
|
Li X, Feng Y, Gong Y, Chen Y. Assessing the Reproducibility of Research Based on the Food and Drug Administration Manufacturer and User Facility Device Experience Data. J Patient Saf 2024; 20:e45-e58. [PMID: 38470959 PMCID: PMC11636620 DOI: 10.1097/pts.0000000000001220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/14/2024]
Abstract
OBJECTIVE This article aims to assess the reproducibility of Manufacturer and User Facility Device Experience (MAUDE) data-driven studies by analyzing the data queries used in their research processes. METHODS Studies using MAUDE data were sourced from PubMed by searching for "MAUDE" or "Manufacturer and User Facility Device Experience" in titles or abstracts. We manually chose articles with executable queries. The reproducibility of each query was assessed by replicating it in the MAUDE Application Programming Interface. The reproducibility of a query is determined by a reproducibility coefficient that ranges from 0.95 to 1.05. This coefficient is calculated by comparing the number of medical device reports (MDRs) returned by the reproduced queries to the number of reported MDRs in the original studies. We also computed the reproducibility ratio, which is the fraction of reproducible queries in subgroups divided by the query complexity, the device category, and the presence of a data processing flow. RESULTS As of August 8, 2022, we identified 523 articles from which 336 contained queries, and 60 of these were executable. Among these, 14 queries were reproducible. Queries using a single field like product code, product class, or brand name showed higher reproducibility (50%, 33.3%, 31.3%) compared with other fields (8.3%, P = 0.037). Single-category device queries exhibited a higher reproducibility ratio than multicategory ones, but without statistical significance (27.1% versus 8.3%, P = 0.321). Studies including a data processing flow had a higher reproducibility ratio than those without, although this difference was not statistically significant (42.9% versus 17.4%, P = 0.107). CONCLUSIONS Our findings indicate that the reproducibility of queries in MAUDE data-driven studies is limited. Enhancing this requires the development of more effective MAUDE data query strategies and improved application programming interfaces.
Collapse
Affiliation(s)
- Xinyu Li
- Department of Computer Science, Vanderbilt University, Nashville, Tennessee
| | - Yubo Feng
- Department of Computer Science, Vanderbilt University, Nashville, Tennessee
| | - Yang Gong
- School of Biomedical Informatics, The University of Texas Health Science Center at Houston, Houston, Texas
| | - You Chen
- Department of Computer Science, Vanderbilt University, Nashville, Tennessee
- Department of Biomedical Informatics, Vanderbilt University Medical Center, Nashville, Tennessee
| |
Collapse
|
2
|
Litwinowicz R, Batko J, Rusinek J, Olejek W, Rams D, Kowalewski M, Bartuś K, Burysz M. LARIAT or AtriClip: Complications Profile and Comparison in Patients with Atrial Fibrillations Based on Manufacturer and User Facility Device Experience Database. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:2055. [PMID: 38138158 PMCID: PMC10744657 DOI: 10.3390/medicina59122055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 11/17/2023] [Accepted: 11/20/2023] [Indexed: 12/24/2023]
Abstract
Background and Objectives: Left atrial appendage closure is an alternative treatment to reduce thromboembolism in patients with atrial fibrillation in whom oral anticoagulation (OAC) is contraindicated. The aim of this study was to evaluate the complications profiles of the LARIAT and AtriClip devices and perform a comparison between them based on the MAUDE (Manufacturer and User Facility Device Experience) database. Materials and Methods: The Manufacturer and User Facility Device Experience database was searched on 15 January 2023. For AtriClip, only reports regarding isolated procedures or procedures associated with minimally invasive ablation were included. Adverse effects and causes of death were defined based on the literature on the topic and the causes described in the reports. In total, 63 patients were included in the LARIAT group and 53 patients were included in the AtriClip group. Results: With the LARIAT device, the most common complication without device problems was pericardial effusion (n = 18, 52.9%), whereas this complication was not observed with AtriClip (p < 0.001). Postoperative bleeding was a second complication that occurred significantly more often in the LARIAT group-in 15 (44.1%) cases versus 1 (2.7%) case with AtriClip (p < 0.001). In addition, significant differences were found in the prevalence of stroke (LARIAT n = 0 vs. AtriClip n = 7, 18.9%, p = 0.012) and thrombus (LARIAT n = 2, 5.9% vs. n = 11, 29.7%, p = 0.013). Conclusions: Each type of left atrial appendage closure procedure is associated with device-specific requirements and complications that, if known, can be avoided.
Collapse
Affiliation(s)
- Radosław Litwinowicz
- CAROL—Cardiothoracic Anatomy Research Operative Lab, Department of Cardiovascular Surgery and Transplantology, Institute of Cardiology, Jagiellonian University Medical College, 31-008 Krakow, Poland
- Department of Cardiac Surgery, Regional Specialist Hospital, 86-300 Grudziądz, Poland
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
| | - Jakub Batko
- CAROL—Cardiothoracic Anatomy Research Operative Lab, Department of Cardiovascular Surgery and Transplantology, Institute of Cardiology, Jagiellonian University Medical College, 31-008 Krakow, Poland
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
| | - Jakub Rusinek
- CAROL—Cardiothoracic Anatomy Research Operative Lab, Department of Cardiovascular Surgery and Transplantology, Institute of Cardiology, Jagiellonian University Medical College, 31-008 Krakow, Poland
| | - Wojciech Olejek
- CAROL—Cardiothoracic Anatomy Research Operative Lab, Department of Cardiovascular Surgery and Transplantology, Institute of Cardiology, Jagiellonian University Medical College, 31-008 Krakow, Poland
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
| | - Daniel Rams
- CAROL—Cardiothoracic Anatomy Research Operative Lab, Department of Cardiovascular Surgery and Transplantology, Institute of Cardiology, Jagiellonian University Medical College, 31-008 Krakow, Poland
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
| | - Mariusz Kowalewski
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Department of Cardiac Surgery and Transplantology, National Medical Institute of the Ministry of Interior and Administration, Wołoska 137 Str., 02-507 Warsaw, Poland
- Cardio-Thoracic Surgery Department, Heart and Vascular Centre, Maastricht University Medical Centre, Cardiovascular Research Institute Maastricht (CARIM), 6229 HX Maastricht, The Netherlands
| | - Krzysztof Bartuś
- Department of Cardiovascular Surgery and Transplantology, Institute of Cardiology, Jagiellonian University Medical College, 31-008 Krakow, Poland
| | - Marian Burysz
- Department of Cardiac Surgery, Regional Specialist Hospital, 86-300 Grudziądz, Poland
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
| |
Collapse
|
3
|
Nestelberger T, Alfadhel M, McAlister C, Saw J. Follow Up imaging After Left Atrial Appendage Occlusion-Something or Nothing and for How Long? Card Electrophysiol Clin 2023; 15:157-168. [PMID: 37076228 DOI: 10.1016/j.ccep.2023.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/21/2023]
Abstract
Routine postprocedural imaging with transesophageal echocardiography or cardiac computed tomography angiography is the most commonly used imaging modality for follow-up surveillance usually performed 1 to 6 months after the procedure. Imaging enables recognition of well-suited and sealed devices in the left atrial appendage as well as of potential harmful complications such as peri-device leaks, device-related thrombus, and device embolization, which may lead to further surveillance observation with recurrent imaging, reinitiation of oral anticoagulants, or additional interventional procedures.
Collapse
Affiliation(s)
- Thomas Nestelberger
- Division of Cardiology, Vancouver General Hospital, University of British Columbia, 2775 Laurel Street, Level 9, Vancouver, BC V5Z1M9, Canada; Cardiovascular Research Institute Basel (CRIB), University Hospital Basel, University of Basel, Basel, Switzerland; Department of Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Mesfer Alfadhel
- Division of Cardiology, Vancouver General Hospital, University of British Columbia, 2775 Laurel Street, Level 9, Vancouver, BC V5Z1M9, Canada
| | - Cameron McAlister
- Division of Cardiology, Vancouver General Hospital, University of British Columbia, 2775 Laurel Street, Level 9, Vancouver, BC V5Z1M9, Canada
| | - Jacqueline Saw
- Division of Cardiology, Vancouver General Hospital, University of British Columbia, 2775 Laurel Street, Level 9, Vancouver, BC V5Z1M9, Canada; Vancouver General Hospital, Basel, British Columbia, Canada; University of British Columbia, 2775 Laurel Street, 9th Floor, Vancouver, British Columbia V5Z 1M9, Canada.
| |
Collapse
|
4
|
Pagani NR, Menendez ME, Moverman MA, Puzzitiello RN, Gordon MR. Adverse Events Associated With Robotic-Assisted Joint Arthroplasty: An Analysis of the US Food and Drug Administration MAUDE Database. J Arthroplasty 2022; 37:1526-1533. [PMID: 35314290 DOI: 10.1016/j.arth.2022.03.060] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 03/08/2022] [Accepted: 03/14/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The use of robotic assistance in arthroplasty is increasing; however, the spectrum of adverse events potentially associated with this technology is unclear. Improved understanding of the causes of adverse events in robotic-assisted arthroplasty can prevent future incidents and enhance patient outcomes. METHODS Adverse event reports to the US Food and Drug Administration Manufacturer and User Facility Device Experience database involving robotic-assisted total hip arthroplasty (THA), total knee arthroplasty (TKA), and partial knee arthroplasty were reviewed to determine causes of malfunction and related patient impact. RESULTS Overall, 263 adverse event reports were included. The most frequently reported adverse events were unexpected robotic arm movement for TKA (59/204, 28.9%) and retained registration checkpoint for THA (19/44, 43.2%). There were 99 reports of surgical delay with an average delay of 20 minutes (range 1-120). Thirty-one cases reported conversion to manual surgery. In total, 68 patient injuries were reported, 7 of which required surgical reintervention. Femoral notching (12/36, 33.3%) was the most common for TKA and retained registration checkpoint (19/28, 67.9%) was the most common for THA. Although rare, additional reported injuries included femoral, tibial, and acetabular fractures, MCL laceration, additional retained foreign bodies, and an electrical burn. CONCLUSION Despite the increasing utilization of robotic-assisted arthroplasty in the United States, numerous adverse events are possible and technical difficulties experienced intraoperatively can result in prolonged surgical delays. The events reported herein seem to indicate that robotic-assisted arthroplasty is generally safe with only a few reported instances of serious complications, the nature of which seems more related to suboptimal surgical technique than technology. Based on our data, the practice of adding registration checkpoints and bone pins to the instrument count of all robotic-assisted TJA cases should be widely implemented to avoid unintended retained foreign objects.
Collapse
Affiliation(s)
| | - Mariano E Menendez
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | | | | | - Matthew R Gordon
- Department of Orthopaedic Surgery, Tufts Medical Center, Boston, MA
| |
Collapse
|
5
|
Nestelberger T, Alfadhel M, McAlister C, Saw J. Follow Up imaging After Left Atrial Appendage Occlusion-Something or Nothing and for How Long? Interv Cardiol Clin 2022; 11:159-170. [PMID: 35361461 DOI: 10.1016/j.iccl.2021.11.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Routine postprocedural imaging with transesophageal echocardiography or cardiac computed tomography angiography is the most commonly used imaging modality for follow-up surveillance usually performed 1 to 6 months after the procedure. Imaging enables recognition of well-suited and sealed devices in the left atrial appendage as well as of potential harmful complications such as peri-device leaks, device-related thrombus, and device embolization, which may lead to further surveillance observation with recurrent imaging, reinitiation of oral anticoagulants, or additional interventional procedures.
Collapse
Affiliation(s)
- Thomas Nestelberger
- Division of Cardiology, Vancouver General Hospital, University of British Columbia, 2775 Laurel Street, Level 9, Vancouver, BC V5Z1M9, Canada; Cardiovascular Research Institute Basel (CRIB), University Hospital Basel, University of Basel, Basel, Switzerland; Department of Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Mesfer Alfadhel
- Division of Cardiology, Vancouver General Hospital, University of British Columbia, 2775 Laurel Street, Level 9, Vancouver, BC V5Z1M9, Canada
| | - Cameron McAlister
- Division of Cardiology, Vancouver General Hospital, University of British Columbia, 2775 Laurel Street, Level 9, Vancouver, BC V5Z1M9, Canada
| | - Jacqueline Saw
- Division of Cardiology, Vancouver General Hospital, University of British Columbia, 2775 Laurel Street, Level 9, Vancouver, BC V5Z1M9, Canada; Vancouver General Hospital, Basel, British Columbia, Canada; University of British Columbia, 2775 Laurel Street, 9th Floor, Vancouver, British Columbia V5Z 1M9, Canada.
| |
Collapse
|
6
|
Chen J, Akoh CC, Kadakia R, Somerson JS, Easley ME, Adams SB, DeOrio JK, Nunley JA. Analysis of 408 Total Ankle Arthroplasty Adverse Events Reported to the US Food and Drug Administration From 2015 to 2018. Foot Ankle Spec 2021; 14:393-400. [PMID: 32383635 DOI: 10.1177/1938640020919538] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Background. Total ankle arthroplasty (TAA) use has increased with newer generation implants. Current reports in the literature regarding complications use data extracted from high-volume centers. The types of complications experienced by lower-volume centers may not be reflected in these reports. The purpose of this study was to determine a comprehensive TAA adverse event profile from a mandatory-reporting regulatory database. Methods. The US Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database was reviewed from 2015 to 2018 to determine reported adverse events for approved implants. Results. Among 408 unique TAA device failures, the most common modes of failure were component loosening (17.9%), intraoperative guide or jig error (15.4%), infection (13.7%), and cyst formation (12.7%). In addition, the percentage distribution of adverse event failure types differed among implants. Conclusion. The MAUDE database is a publicly available method that requires mandatory reporting of approved device adverse events. Using this report, we found general agreement in types of complications reported in the literature, although there were some differences, as well as differences between implants. These data may more accurately reflect a comprehensive profile of TAA complications as data were taken from a database of all device users rather than only high-volume centers.Levels of Evidence: NA.
Collapse
Affiliation(s)
- Jie Chen
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina (JC, CCA, RK, MEE, SBA, JKD, JAN).,Department of Orthopaedic Surgery and Rehabilitation, University of Texas Medical Branch, Galveston, Texas (JC, JSS)
| | - Craig C Akoh
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina (JC, CCA, RK, MEE, SBA, JKD, JAN).,Department of Orthopaedic Surgery and Rehabilitation, University of Texas Medical Branch, Galveston, Texas (JC, JSS)
| | - Rishin Kadakia
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina (JC, CCA, RK, MEE, SBA, JKD, JAN).,Department of Orthopaedic Surgery and Rehabilitation, University of Texas Medical Branch, Galveston, Texas (JC, JSS)
| | - Jeremy S Somerson
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina (JC, CCA, RK, MEE, SBA, JKD, JAN).,Department of Orthopaedic Surgery and Rehabilitation, University of Texas Medical Branch, Galveston, Texas (JC, JSS)
| | - Mark E Easley
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina (JC, CCA, RK, MEE, SBA, JKD, JAN).,Department of Orthopaedic Surgery and Rehabilitation, University of Texas Medical Branch, Galveston, Texas (JC, JSS)
| | - Samuel B Adams
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina (JC, CCA, RK, MEE, SBA, JKD, JAN).,Department of Orthopaedic Surgery and Rehabilitation, University of Texas Medical Branch, Galveston, Texas (JC, JSS)
| | - James K DeOrio
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina (JC, CCA, RK, MEE, SBA, JKD, JAN).,Department of Orthopaedic Surgery and Rehabilitation, University of Texas Medical Branch, Galveston, Texas (JC, JSS)
| | - James A Nunley
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina (JC, CCA, RK, MEE, SBA, JKD, JAN).,Department of Orthopaedic Surgery and Rehabilitation, University of Texas Medical Branch, Galveston, Texas (JC, JSS)
| |
Collapse
|
7
|
MAUDE Database Analysis of Post-Approval Outcomes following Left Atrial Appendage Closure with the Watchman Device. Am J Cardiol 2021; 152:78-87. [PMID: 34116792 DOI: 10.1016/j.amjcard.2021.04.015] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Revised: 04/11/2021] [Accepted: 04/13/2021] [Indexed: 11/20/2022]
Abstract
Left atrial appendage closure (LAAC) is an important strategy to reduce stroke risk in patients with non-valvular atrial fibrillation (AF) who are at high risk of bleeding on long-term anticoagulation. Real-world assessments of the safety of the Watchman LAAC device remain limited. The objective of this study was to determine the frequency and timing of adverse events associated with Watchman LAAC device implants performed after FDA approval. Adverse events associated with Watchman LAAC implants performed between March 2015 and March 2019 were identified through a search of the FDA Manufacturer and User Facility Device Experience (MAUDE) database. During the study period, 3,652 unique adverse events were identified. An estimated 43,802 Watchman implants were performed in the United States during the study period. The overall adverse event rate was 7.3% and the mortality rate was 0.4%. Of the 159 unique types of adverse events identified, pericardial effusion was most common (1.4%). Most adverse events (73%) occurred intraoperatively (59%) or within 1 day of the procedure (15%). However, 19% of deaths, 24% of strokes and 27% of device embolizations occurred >1 month after implantation. The rates of most Watchman-related adverse events reported in the MAUDE database were comparable to those observed in clinical trials. A majority of adverse events occurred within 1 day of implant. In conclusion, while the absolute event rates were low, a significant proportion of device embolizations, strokes, and deaths occurred >1 month after Watchman implant.
Collapse
|
8
|
Strategies for Recovering an Embolized Percutaneous Device. Curr Cardiol Rep 2021; 23:123. [PMID: 34269875 DOI: 10.1007/s11886-021-01554-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 03/17/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE OF REVIEW Device embolization is a rare but potentially life-threatening complication of transcatheter structural heart interventions and may require prompt intervention. The present work aims to provide an overview of strategies for device retrievals in order to better guide the evaluation and management of device embolization. RECENT FINDINGS Although the evolution of transcatheter device therapies has had a tremendous impact on the management in structural heart disease, availability of various retrieval devices, knowledge in how to use them, and multidisciplinary collaboration are key for successful device retrieval. Understanding the reasons for embolization, strategies to avoid embolization, and the techniques for retrieval of devices used in structural heart disease should be appreciated by the treating physician.
Collapse
|
9
|
Sabzwari SRA, Mehta NA, Garg L, Racharla L, Kurtz E, Afzal MR, Turagam MK, Lakkireddy D. Safety and efficacy of left atrial appendage closure using an epicardial suture snaring device: Systematic review and current status. J Cardiovasc Electrophysiol 2021; 32:2189-2198. [PMID: 34164881 DOI: 10.1111/jce.15132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 04/29/2021] [Accepted: 05/31/2021] [Indexed: 11/29/2022]
Abstract
INTRODUCTION The LARIAT epicardial suture snaring device has been fraught with technical challenges and procedural complications. Over time, technique modification and improved operator experience have helped overcome many of these challenges. METHODS AND RESULTS: Studies reporting left atrial appendage epicardial closure over a 12-year period from 2009 to 2020 were evaluated. The primary efficacy outcome evaluated was left atrial appendage closure with residual flow ≤1 mm. Safety outcomes evaluated were periprocedural and long term complications after device placement. Nine studies consisting of 1430 patients were included in this analysis, of which 1386 (97%) underwent successful device placement. The mean age was 69.3 years, with a mean CHADS2 -VASC score of 3.78. Primary efficacy end point was achieved in 95.8% patients immediately after device placement, and in 92.8% patients on long term follow-up. Early procedural complications consisted of pericardial effusion 5.6%, cardiac perforation 2.7%, pericarditis 2.6%, and need for open heart surgery 1.5%. Long term complications consisted of all-cause mortality 2.3%, stroke 1.5%, and left atrial appendage thrombus 2.3%. Reduced complications were noted using micropuncture needles (2.20% vs. 10.14%; p < .0001), a longer duration pericardial drainage, and use of anti-inflammatory medications (1.58% vs. 8.4%). Oral anticoagulation use decreased from 44.7% to 22.9% post device implantation, and to 8.5% on last clinical follow up. CONCLUSIONS The LARIAT device is effective in epicardial closure of the left atrial appendage. Improvement in device techniques such as use of micropuncture needle, prophylactic colchicine, and maintenance of a pericardial drain have helped improve safety over time.
Collapse
Affiliation(s)
| | - Nikhil A Mehta
- Department of Cardiology, Lehigh Valley Health Network, Allentown, Pennsylvania, USA
| | - Lohit Garg
- Department of Electrophysiology, Hospital of the University of Pennsylvania, Pennsylvania, USA
| | - Lekha Racharla
- Department of Cardiology, Lehigh Valley Health Network, Allentown, Pennsylvania, USA
| | - Emilee Kurtz
- Department of Internal Medicine, Lehigh Valley Health Network, Allentown, Pennsylvania, USA
| | - Muhammad R Afzal
- Department of Electrophysiology, Ohio State University, Columbus, Ohio, USA
| | - Mohit K Turagam
- Department of Electrophysiology, The Mount Sinai Hospital, New York City, New York, USA
| | - Dhanunjaya Lakkireddy
- Department of Electrophysiology, Overland Park Regional Medical Center, Overland Park, Kansas, USA
| |
Collapse
|
10
|
Akoh CC, Chen J, Kadakia R, Park YU, Kim H, Adams SB. Adverse events involving hallux metatarsophalangeal joint implants: Analysis of the United States Food and Drug Administration data from 2010 to 2018. Foot Ankle Surg 2021; 27:381-388. [PMID: 32505511 DOI: 10.1016/j.fas.2020.05.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 04/27/2020] [Accepted: 05/08/2020] [Indexed: 02/04/2023]
Abstract
BACKGROUND The prevalence of osteoarthritis of the hallux metatarsophalangeal joint (MTPJ) is 1 in 40 people over the age of 50. Surgical treatment options for MTPJ arthritis include joint preservation, joint resurfacing, and arthrodesis. Hallux MTPJ implants have evolved over the past several decades, but are associated with various complications. The aim of this study was to examine the MAUDE database to determine reported adverse events for hallux MTPJ implants. MATERIALS AND METHODS The US Food and Drug Administration's (FDA) Manufacturer and User Facility Device Experience (MAUDE) database was reviewed from 2010 to 2018 to review voluntary reported adverse event reports for approved implants within the United States. We recorded the type of adverse event and excluded duplicate reports and those extracted from already published literature. RESULTS Among 64 reported hallux MTPJ implant adverse events, the most common modes of adverse events were component loosening (34%), infection (14.1%), component fracture (9.4%), inflammation (9.4%), and allergic reaction (7.8%). Regarding implant type, Cartiva SCI had the highest percentage of adverse events (23.4%), followed by Arthrosurface ToeMotion (20.3%), Ascension MGT (12.5%), Arthrosurface HemiCAP® (10.9%), Futura primus (9.4%), and Osteomed Reflexion (6.3%). There was an increase in reported adverse events after 2016. The MAUDE database does not report the total incidence of implant insertion. CONCLUSION Our study of the MAUDE database demonstrated that component loosening and infection are the most common modes of adverse events for hallux MTPJ implants. Cartiva accounted for one-fourth of the implant-related adverse events during our study period, followed by ToeMotion, and Ascension MGT implants. Continued reporting of adverse events will improve our understanding on short and long-term complications of various hallux MTPJ implants. LEVEL OF EVIDENCE Level IV; Case Series from Large Database Analysis; Treatment Study.
Collapse
Affiliation(s)
- Craig C Akoh
- Duke University Medical Center, Box 2887, Durham, NC 27710, United States.
| | - Jie Chen
- Duke University Medical Center, Box 2887, Durham, NC 27710, United States
| | - Rishin Kadakia
- Duke University Medical Center, Box 2887, Durham, NC 27710, United States
| | - Young Uk Park
- Department of Orthopedic Surgery, Ajou University Hospital, Ajou University School of Medicine, Suwon, Gyeonggido, Republic of Korea
| | - Hyongnyun Kim
- Department of Orthopedic Surgery, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Republic of Korea
| | - Samuel B Adams
- Duke University Medical Center, Box 2887, Durham, NC 27710, United States
| |
Collapse
|
11
|
Liu B, Luo J, Gong M, Li Z, Shi B, Zhang X, Han X, Wei Y. Five-Year Outcomes and Cardiac Remodeling Following Left Atrial Appendage Occlusion. Clin Interv Aging 2021; 16:655-663. [PMID: 33907387 PMCID: PMC8064621 DOI: 10.2147/cia.s296639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Accepted: 03/18/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose LAAO has been an alternative therapy to oral anticoagulants (OACs) for stroke prophylaxis in patients with nonvalvular atrial fibrillation (NVAF) with elevated CHA2DS2-Vasc score, but the long-term outcomes of LAAO and its impacts on cardiac electrical and mechanical remodeling remain to be learned. We aimed to describe the impact of left atrial appendage occlusion (LAAO) on atrial remodeling and cardiovascular outcomes within 5-year follow-up. Patients and Methods A total of 107 patients with nonvalvular atrial fibrillation (NVAF) undergoing LAAO in the Shanghai Tenth People’s Hospital between January 2014 and July 2017 were included. All participants were followed for ECG, transthoracic echocardiography (TTE), and clinical outcomes (including cardiovascular death, heart failure, ischemic stroke/systemic embolism, and pericardial effusion) at 6 and 12 months, and thereafter every 12 months after LAAO discharge until 5 years. Results After LAAO, the left atrial diameter significantly increased at 6 months (48.6 ± 6.7 vs 46.5 ± 7.0 mm); heart rate decreased immediately after the procedure (78.5 ± 14.7 vs 85.3 ± 21.7 bpm) when compared with the pre-procedure level. The QTc interval prolongated to the highest value of 460.7 ± 46.8 ms at 6 months (pre-procedure level of 433.7±49.0 ms). All these changes return to the pre-procedure level within the follow-up. For clinical outcomes, 51 patients suffered the composite of cardiovascular death (n=4, 3.7%), heart failure (n=25, 23.4%), ischemic stroke/systemic embolism (n=22, 20.6%), and pericardial effusion (n=26, 26.2%). Conclusion LAAO did not change ECG or TTE characteristics and nonprocedure-related pericardial effusion is common during long-term follow-up. Further studies are warranted to investigate the optimal time frame of anticoagulation in patients undergoing LAAO.
Collapse
Affiliation(s)
- Baoxin Liu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, People's Republic of China
| | - Jiachen Luo
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, People's Republic of China
| | - Mengmeng Gong
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, People's Republic of China
| | - Zhiqiang Li
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, People's Republic of China
| | - Beibei Shi
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, People's Republic of China
| | - Xingxu Zhang
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, People's Republic of China
| | - Xinqiang Han
- Electrophysiology and Arrhythmia Services, Reid Health, Indiana University School of Medicine, Richmond, IN, 47374, USA
| | - Yidong Wei
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, People's Republic of China
| |
Collapse
|
12
|
Ziapour B, Zaepfel C, Iafrati MD, Suarez LB, Salehi P. A systematic review of the quality of cardiovascular surgery studies that extracted data from the MAUDE database. J Vasc Surg 2021; 74:1708-1720.e5. [PMID: 33600931 DOI: 10.1016/j.jvs.2021.01.050] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Accepted: 01/08/2021] [Indexed: 10/22/2022]
Abstract
OBJECTIVE To investigate opportunities and limitations of using the Manufacturer and User Facility Device Experience (MAUDE) database for cardiovascular surgery research, we analyzed the quality of studies having ever used MAUDE, in the field of cardiovascular surgery. METHODS We systematically searched the Cochrane Library, PubMed, EMBASE, and Google Scholar for randomized and nonrandomized studies, from inception to July 2019. Two authors evaluated the quality of the retrieved observational studies, according to the National Institutes of Health quality assessment tool for either case series or cross-sectional studies. These tools quantify the quality of case series and cohorts/cross-sectional studies, respectively, with nine and 14 queries. RESULTS Fifty-eight studies were included in the final qualitative review. Of 58 identified studies, 32 were case series, 8 were abstracts of case series, and 13 were reviews or case discussion with an included series from MAUDE. Also, five articles were cross-sectional studies. Of the 32 formal case series, 26 (81%) were found to have poor quality. The most common reasons for a poor quality designation included a lack of consecutive participants, undetermined comparability of participants, and undetermined follow-up adequacy. Only one out of five cross-sectional studies had fair quality; four others were evaluated as poor quality studies. CONCLUSIONS Cardiovascular surgery studies using the MAUDE database, whether case series or cross-sectional design, are mostly of poor quality. Their low quality is partly caused by poor study design, but mainly by intrinsic limitations to the MAUDE database: cases recruited are not consecutive; patient characteristics are not detailed enough to allow a meaningful comparison of patient characteristics between different patient entries; outcome measures are unclear; there is a limited follow-up; and time-to-event data are lacking. We conclude that the quality of cardiovascular surgery publications that rely on data from MAUDE could be improved if investigators were to extract all relevant data points from MAUDE entries, then apply standard quality assessment tools in compiling and reporting the data. MAUDE might be improved if it used medical case report standards during the process of reporting and indexing adverse events. To calculate the incidence rate of any adverse event, all event-free cases, as well as all adverse events in patients using a device, are required. Neither of these two variables is available in the MAUDE at the time of writing.
Collapse
Affiliation(s)
- Behrad Ziapour
- Department of General Surgery, Allegheny General Hospital, Pittsburgh, Pa
| | | | - Mark D Iafrati
- Division of Vascular Surgery, Cardiovascular Center at Tufts Medical Center, Boston, Mass
| | - Luis B Suarez
- Cardiovascular Center at Tufts Medical Center, Boston, Mass
| | - Payam Salehi
- Division of Vascular Surgery, Cardiovascular Center at Tufts Medical Center, Boston, Mass.
| |
Collapse
|
13
|
Nentwich K, Ene E, Halbfass P, Berkowitz A, Sonne K, Kerber S, Lee R, Deneke T. Concomitant epicardial left atrial appendage ligation and left atrial ablation of atrial fibrillation: Safety, feasibility and outcome. Indian Pacing Electrophysiol J 2021; 21:75-79. [PMID: 33460777 PMCID: PMC7952894 DOI: 10.1016/j.ipej.2021.01.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 01/07/2021] [Accepted: 01/09/2021] [Indexed: 11/27/2022] Open
Abstract
Introduction We present initial results of patients undergoing a combined procedure of epicardial LAA ligation in addition to left atrial ablation for AF. Methods 9 patients were included for additional use of LARIAT as an individual treatment approach for AF. First an epicardial LAA ligation was performed, in the same procedure left atrial ablations consisting of PVI and additional substrate based modifying ablations were performed. Follow–up at 3 months and 12 months was performed. Results There was only 1 minor procedural complication (11%) involving epicardial bleeding and 2 late adverse events of pericardial tamponade and stroke. At the final follow-up (median 20 months) 7 patients were in stable sinus rhythm (78%) and 2 pts had reduced AF burden. Conclusion Concomitant epicardial LAA ligation and ablation is feasible in selected patients with a reasonable risk profile. More prospective data are required to validate the safety and efficacy.
Collapse
Affiliation(s)
- Karin Nentwich
- Campus Bad Neustadt, Department Cardiology and Invasive Electrophysiology, von Guttenbergstrasse 11, 97616, Bad Neustadt, Germany.
| | - Elena Ene
- Campus Bad Neustadt, Department Cardiology and Invasive Electrophysiology, von Guttenbergstrasse 11, 97616, Bad Neustadt, Germany
| | - Philipp Halbfass
- Campus Bad Neustadt, Department Cardiology and Invasive Electrophysiology, von Guttenbergstrasse 11, 97616, Bad Neustadt, Germany
| | - Arthur Berkowitz
- Campus Bad Neustadt, Department Cardiology and Invasive Electrophysiology, von Guttenbergstrasse 11, 97616, Bad Neustadt, Germany
| | - Kai Sonne
- Campus Bad Neustadt, Department Cardiology and Invasive Electrophysiology, von Guttenbergstrasse 11, 97616, Bad Neustadt, Germany
| | - Sebastian Kerber
- Campus Bad Neustadt, Department Cardiology and Invasive Electrophysiology, von Guttenbergstrasse 11, 97616, Bad Neustadt, Germany
| | - Randall Lee
- Section of Cardiac Electrophysiology, Division of Cardiology, University of California, 500 Parnassus Ave, San Francisco, CA, 94143, USA
| | - Thomas Deneke
- Campus Bad Neustadt, Department Cardiology and Invasive Electrophysiology, von Guttenbergstrasse 11, 97616, Bad Neustadt, Germany
| |
Collapse
|
14
|
NCDR Left Atrial Appendage Occlusion Registry: The "Watch" Man Has Arrived. J Am Coll Cardiol 2020; 75:1519-1522. [PMID: 32238317 DOI: 10.1016/j.jacc.2020.01.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Accepted: 01/14/2020] [Indexed: 11/21/2022]
|
15
|
Litwinowicz R, Burysz M, Mazur P, Kapelak B, Bartus M, Lakkireddy D, Lee RJ, Malec‐Litwinowicz M, Bartus K. Endocardial versus epicardial left atrial appendage exclusion for stroke prevention in patients with atrial fibrillation: Midterm follow‐up. J Cardiovasc Electrophysiol 2020; 32:93-101. [DOI: 10.1111/jce.14802] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 09/28/2020] [Accepted: 10/09/2020] [Indexed: 01/09/2023]
Affiliation(s)
- Radoslaw Litwinowicz
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University Medical College John Paul II Hospital Krakow Poland
| | - Marian Burysz
- Department of Cardiac Surgery Regional Specialist Hospital Grudziadz Poland
| | - Piotr Mazur
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University Medical College John Paul II Hospital Krakow Poland
| | - Boguslaw Kapelak
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University Medical College John Paul II Hospital Krakow Poland
| | - Magdalena Bartus
- Departament of Pharmacology Jagiellonian University Medical College Krakow Poland
| | - Dhanunjaya Lakkireddy
- The Kansas City Heart Rhythm Institute & Research Foundation Overland Park Kansas USA
| | - Randall J. Lee
- Department of Medicine and Cardiovascular Research Institute University of California San Francisco California USA
| | | | - Krzysztof Bartus
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University Medical College John Paul II Hospital Krakow Poland
| |
Collapse
|
16
|
Litwinowicz R, Mazur P, Burysz M, Filip G, Wasilewski G, Kapelak B, Bartus K. Why should cardiac surgeons occlude the left atrial appendage percutaneously? J Card Surg 2020; 35:3458-3464. [PMID: 32939852 DOI: 10.1111/jocs.14991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Percutaneous left atrial appendage (LAA) occlusion (LAAO) is a procedure dominated by cardiologists. The aim of our study was to present the results of percutaneous LAAO performed solely by cardiac surgeons. METHODS Two hundred twenty-three consecutive patients with nonvalvular atrial fibrillation underwent percutaneous LAAO in two cardiac surgery sites. In the first center, all 84 LAAO procedures were performed with the endocardial LAA occluders: 60 cases with the Amulet and 24 cases with the LAmbre. In the second center, all 139 LAAO procedures were performed with the LARIAT epicardial device. RESULTS The mean CHA2 DS2 -VASc-score was 3.7 ± 1.8 points, and mean HAS-BLED score was 3.6 ± 1.2 points. The procedure was successful in 97.3% of cases. Procedural or device-related adverse events were noted in 4.4% (n = 10) of cases: one periprocedural cardiac arrest, one aortic injury, one gastrointestinal bleeding, three cases of vascular access complications, and four cardiac tamponades. After a follow-up of 40.3 ± 17.3 months, 78.4% of patients were alive, with the annual mortality rate of 5.3%. Compared to the predicted risk, the observed incidence of thromboembolism was lower by 71%, and the bleeding incidence was lower by 69%. CONCLUSIONS Percutaneous LAAO procedures can be safely performed by cardiac surgeons, with no cardiological assistance. LAAO done by surgeons is safe and effective, and periprocedural and long-term outcomes are excellent. Cardiac surgeons should be trained in both types of LAAO: endocardial and epicardial.
Collapse
Affiliation(s)
- Radoslaw Litwinowicz
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University Medical College, Kraków, Poland.,Department of Cardiovascular Surgery and Transplantology, John Paul II Hospital, Kraków, Poland
| | - Piotr Mazur
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University Medical College, Kraków, Poland.,Department of Cardiovascular Surgery and Transplantology, John Paul II Hospital, Kraków, Poland
| | - Marian Burysz
- Department of Cardiac Surgery, Regional Specialist Hospital, Grudziadz, Poland
| | - Grzegorz Filip
- Department of Cardiovascular Surgery and Transplantology, John Paul II Hospital, Kraków, Poland
| | - Grzegorz Wasilewski
- Department of Cardiovascular Surgery and Transplantology, John Paul II Hospital, Kraków, Poland
| | - Boguslaw Kapelak
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University Medical College, Kraków, Poland.,Department of Cardiovascular Surgery and Transplantology, John Paul II Hospital, Kraków, Poland
| | - Krzysztof Bartus
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University Medical College, Kraków, Poland.,Department of Cardiovascular Surgery and Transplantology, John Paul II Hospital, Kraków, Poland
| |
Collapse
|
17
|
Murtaza G, Boda U, Turagam MK, Della Rocca DG, Akella K, Gopinathannair R, Lakkireddy D. Risks and Benefits of Removal of the Left Atrial Appendage. Curr Cardiol Rep 2020; 22:129. [PMID: 32910248 DOI: 10.1007/s11886-020-01387-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
PURPOSE OF REVIEW In patients with atrial fibrillation who are unable to take novel oral anticoagulants for stroke prophylaxis due to bleeding risk or other contraindications, left atrial appendage (LAA) occlusion and exclusion devices have shown benefit. In this review, we highlight the risks and benefits associated with LAA removal. RECENT FINDINGS LAA, once considered a vestigial organ, has been shown to have physiological, anatomical, and arrhythmogenic properties. Device-related complications such as pericardial effusion, device embolization, device-related thrombus, while uncommon, are still present. With increased operator experience related to appendage occlusion, overall procedural complications have declined. Further refinements in device technology will help decrease complications. While benefits of appendage removal are plenty, procedural complications need to be weighed into the equation when making decisions regarding LAA occlusion.
Collapse
Affiliation(s)
- Ghulam Murtaza
- The Kansas City Heart Rhythm Institute (KCHRI) & Research Foundation, Overland Park Regional Medical Center, HCA MidWest, 12200, W 106th Street, Overland Park, KS, 66215, USA
| | - Urooge Boda
- The Kansas City Heart Rhythm Institute (KCHRI) & Research Foundation, Overland Park Regional Medical Center, HCA MidWest, 12200, W 106th Street, Overland Park, KS, 66215, USA
| | - Mohit K Turagam
- Department of Cardiovascular Diseases, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | | | - Krishna Akella
- The Kansas City Heart Rhythm Institute (KCHRI) & Research Foundation, Overland Park Regional Medical Center, HCA MidWest, 12200, W 106th Street, Overland Park, KS, 66215, USA
| | - Rakesh Gopinathannair
- The Kansas City Heart Rhythm Institute (KCHRI) & Research Foundation, Overland Park Regional Medical Center, HCA MidWest, 12200, W 106th Street, Overland Park, KS, 66215, USA
| | - Dhanunjaya Lakkireddy
- The Kansas City Heart Rhythm Institute (KCHRI) & Research Foundation, Overland Park Regional Medical Center, HCA MidWest, 12200, W 106th Street, Overland Park, KS, 66215, USA.
| |
Collapse
|
18
|
Vuddanda VLK, Turagam MK, Umale NA, Shah Z, Lakkireddy DR, Bartus K, McCausland FR, Velagapudi P, Mansour M, Heist EK. Incidence and causes of in-hospital outcomes and 30-day readmissions after percutaneous left atrial appendage closure: A US nationwide retrospective cohort study using claims data. Heart Rhythm 2019; 17:374-382. [PMID: 31539630 DOI: 10.1016/j.hrthm.2019.09.018] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2019] [Indexed: 11/19/2022]
Abstract
BACKGROUND Percutaneous left atrial appendage closure (pLAAC) emerged as an option for stroke prevention in patients with atrial fibrillation ineligible for long-term anticoagulation. Real-world data on pLAAC's in-hospital and 30-day readmission measures are limited. OBJECTIVE We sought to report the nationwide incidence of the above outcomes using 2016 claims data. METHODS We used the National Inpatient Sample for in-hospital outcomes and Nationwide Readmissions Database for readmissions. We identified hospitalizations with a primary diagnosis of atrial fibrillation and pLAAC procedure by using International Classification of Diseases, Tenth Revision codes and compared the outcomes mentioned above between the endocardial and epicardial cohorts. Statistical analyses were performed using R 3.3.2. RESULTS Among 5480 pLAAC procedures (endocardial: 5145; epicardial: 335), the in-hospital mortality was 0.3%. Endocardial left atrial appendage closure (LAAC) had lower complications (8.5% vs 25.4%; P < .001) and shorter length of stay median [interquartile range] 1 [1-1] day vs 2 [1-3] days; P < .001) but higher hospitalization cost (24.13 [18.45-30.17] × 1000 dollars vs 21.21 [14.03-27.86] × 1000 dollars; P = .016). The most common complications include pericardial (endocardial vs epicardial: 3% vs 10.4%; P < .001) and renal failure (1.4% vs 6.0%; P = .004). Epicardial LAAC had higher 30-day unplanned readmissions (19.5% vs 8.3%; P = .001), with the most common reason being pericarditis and/or effusion (33.9%). CONCLUSION Endocardial LAAC had lower complications and 30-day readmissions but higher hospitalization cost. Although epicardial LAAC showed higher complications, given recent improvements in its technique, and postprocedural care demonstrated a significant reduction in pericardial complications, more contemporary data comparing these outcomes are needed.
Collapse
Affiliation(s)
- Venkat L K Vuddanda
- Department of General Internal Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts
| | - Mohit K Turagam
- Helmsley Centre for Cardiac Electrophysiology, Mount Sinai Hospital, New York, New York
| | - Nikita A Umale
- Department of Emergency Medicine, Brigham & Women's Hospital, Boston, Massachusetts
| | - Zubair Shah
- Cardiovascular Research Institute, The Kansas University Hospital, Kansas City, Kansas
| | - Dhanunjaya R Lakkireddy
- Division of cardiac electrophysiology, Kansas City Heart Rhythm Institute and Research Foundation, Kansas City, Kansas
| | - Krzysztof Bartus
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University Medical College, John Paul II Hospital, Krakow, Poland
| | - Finnian R McCausland
- Renal Division, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts
| | - Poonam Velagapudi
- Division of Cardiovascular Medicine, University of Nebraska Medical Center, Omaha, Nebraska
| | - Moussa Mansour
- Division of Cardiac Electrophysiology, Corrigan Minehan Heart Center, Massachusetts General Hospital, Boston, Massachusetts
| | - E Kevin Heist
- Division of Cardiac Electrophysiology, Corrigan Minehan Heart Center, Massachusetts General Hospital, Boston, Massachusetts.
| |
Collapse
|
19
|
Mohanty S, Gianni C, Trivedi C, Gadiyaram V, Della Rocca DG, MacDonald B, Horton R, Al-Ahmad A, Gibson DN, Price M, Krumerman AK, Palma EC, Di Biase L, Lakkireddy D, Natale A. Risk of thromboembolic events after percutaneous left atrial appendage ligation in patients with atrial fibrillation: Long-term results of a multicenter study. Heart Rhythm 2019; 17:175-181. [PMID: 31400519 DOI: 10.1016/j.hrthm.2019.08.003] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Indexed: 10/26/2022]
Abstract
BACKGROUND Percutaneous left atrial appendage (LAA) occlusion with Lariat has emerged as a viable alternative to oral anticoagulation (OAC) to prevent thromboembolic (TE) events in patients with atrial fibrillation. OBJECTIVE We evaluated the long-term TE risk in post-Lariat patients. METHODS Consecutive patients undergoing LAA ligation with the Lariat device at multiple centers with at least 1-year follow-up were included in the analysis. Transesophageal echocardiography (TEE) was performed at 4 weeks, 6 months, and 12 months to assess the completeness of LAA occlusion. OAC was discontinued if 4-week TEE revealed no device-related thrombus and complete closure of the appendage. Patients remained on 81 mg of aspirin per day after discontinuation of the blood thinner. RESULTS A total of 306 patients were included in the study (mean age 68.8 ± 11.0 years; mean CHA2DS2-VASc score 3.6 ± 1.7). Four-week TEE revealed leaks in 81 patients (26.5%); all leaks were less than 5 mm in diameter. At 6-month TEE, spontaneous closure of the leak was demonstrated in 21 patients (25.9%), 26 patients (32%) underwent a successful leak closure procedure, and the remaining 34 (42%) patients were placed on OAC. At the median follow-up period of 15.9 ± 9.2 months, 9 TE events (2.9%) were reported: 7 with persistent leak and 2 without any detectable leaks on 2-dimensional TEE (P < .001). CONCLUSION Complete occlusion of the LAA with the Lariat device was associated with the low rate of TE events at long-term follow-up. However, residual leaks were common after Lariat closure and the stroke rate was significantly higher in patients with incomplete occlusion, even with small leaks.
Collapse
Affiliation(s)
- Sanghamitra Mohanty
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas; Department of Internal Medicine, Dell Medical School, Austin, Texas
| | - Carola Gianni
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas
| | - Chintan Trivedi
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas
| | - Varuna Gadiyaram
- Interventional Electrophysiology, Scripps Clinic, San Diego, California
| | | | - Bryan MacDonald
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas
| | - Rodney Horton
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas
| | - Amin Al-Ahmad
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas
| | - Douglas N Gibson
- Interventional Electrophysiology, Scripps Clinic, San Diego, California
| | - Matthew Price
- Interventional Electrophysiology, Scripps Clinic, San Diego, California
| | - Andrew K Krumerman
- Albert Einstein College of Medicine, Montefiore Medical Center, New York City, New York
| | - Eugen C Palma
- Albert Einstein College of Medicine, Montefiore Medical Center, New York City, New York
| | - Luigi Di Biase
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas; Albert Einstein College of Medicine, Montefiore Medical Center, New York City, New York
| | | | - Andrea Natale
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas; Department of Internal Medicine, Dell Medical School, Austin, Texas; Interventional Electrophysiology, Scripps Clinic, San Diego, California; Metro Health Medical Center, Case Western Reserve University School of Medicine, Cleveland, Ohio; Division of Cardiology, Stanford University, Stanford, California.
| |
Collapse
|
20
|
Timely recognition of total elbow and radial head arthroplasty adverse events: an analysis of reports to the US Food and Drug Administration. J Shoulder Elbow Surg 2019; 28:510-519. [PMID: 30466818 DOI: 10.1016/j.jse.2018.08.043] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Revised: 08/23/2018] [Accepted: 08/29/2018] [Indexed: 02/01/2023]
Abstract
BACKGROUND Recent recalls of several commonly used elbow arthroplasty implants have prompted interest in the modes by which elbow implants fail and the timing of reports of these failures. METHODS We reviewed the adverse event reports to the US Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database from 2012 to 2015 regarding elbow arthroplasty to determine the event date and the type of each adverse event. RESULTS Among 179 total elbow adverse event reports, the most common modes of failure were implant dissociation (23%), loosening (22%), and infection (16%). The most common modes of failure among 58 radial head replacement reports were component dissociation (19%) and linkage screw failure (19%). The percentage distribution of adverse event types differed among different arthroplasty systems and from that reported in published reviews of elbow arthroplasty. Three implant recalls were implemented 2, 5, and 9 years after the first adverse event report in the MAUDE database. For 2 of the recalls, the first reports of the device failures were published 2 and 5 years after the first MAUDE reports. CONCLUSIONS The MAUDE database is a publicly funded and publicly available means by which surgeons can identify adverse events for the prostheses they use before such information becomes available through journal publication or recall notification. In this study, MAUDE data revealed a higher relative frequency of mechanical dissociation of elbow implants than what has been represented in the literature. Early identification of these adverse events may help surgeons by informing their implant selection and surgical technique.
Collapse
|
21
|
Litwinowicz R, Bartus M, Ceranowicz P, Brzezinski M, Kapelak B, Lakkireddy D, Bartus K. Left atrial appendage occlusion for stroke prevention in diabetes mellitus patients with atrial fibrillation: Long-term results. J Diabetes 2019; 11:75-82. [PMID: 29999242 DOI: 10.1111/1753-0407.12824] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Revised: 06/13/2018] [Accepted: 07/07/2018] [Indexed: 01/30/2023] Open
Abstract
BACKGROUND Concomitant diabetes mellitus (DM) in atrial fibrillation (AF) may increase the risk of thromboembolism. Left atrial appendage occlusion (LAAO) is an alternative treatment in AF patients in whom antithrombotic therapy is ineffective or contraindicated. The aim of this study was to evaluate the long-term efficacy of LAAO in DM patients with AF. METHODS A retrospective study was conducted in 139 patients who had undergone LAAO and were categorized into two groups: 28 patients with DM and 111 patients without DM. Overall, the follow-up period was 530 patient-years. RESULTS Mean CHADS2 and CHA2 DS2 -VASc scores were higher in patients with than without DM (2.6 vs 1.7 [P < 0.001] and 3.5 vs 2.8 [P = 0.056], respectively). There were no significant differences between the two groups in terms of HAS-BLED scores and other patient factors (sex, age, heart failure, hypertension, previous stroke or transient ischemic attack, peripheral vascular disease) that may increase the risk of thromboembolism based on CHA2 DS2 -VASc. The mean follow-up period was 51.6 and 50 months in patients with DM and without DM, respectively. Comparing patients with and without DM, there were no significant differences in thromboembolic events (4% vs 1.9%), severe bleeding (0% vs 3.1%), or mortality (4% vs 5.9%). The estimated reductions in thromboembolic and bleeding risk were 77% and 100%, respectively, for patients with DM, compared with 85% and 62%, respectively, for patients without DM. CONCLUSION The present study indicates that LAAO in AF patients with DM has similar safety endpoints and long-term efficacy as LAAO in patients without DM.
Collapse
Affiliation(s)
- Radoslaw Litwinowicz
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University, John Paul II Hospital, Krakow, Poland
| | - Magdalena Bartus
- Deopartment of Pharmacology, Jagiellonian University, Krakow, Poland
| | - Piotr Ceranowicz
- Department of Physiology, Jagiellonian University, Krakow, Poland
| | - Maciej Brzezinski
- Department of Cardiac and Vacsular Surgery, Medical University of Gdansk, Gdansk, Poland
| | - Bogusław Kapelak
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University, John Paul II Hospital, Krakow, Poland
| | - Dhanunjaya Lakkireddy
- Division of Cardiovascular Diseases, Cardiovascular Research Institute, University of Kansas, Kansas City, Missouri, USA
| | - Krzysztof Bartus
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University, John Paul II Hospital, Krakow, Poland
| |
Collapse
|
22
|
Device Embolization in Structural Heart Interventions. JACC Cardiovasc Interv 2019; 12:113-126. [DOI: 10.1016/j.jcin.2018.08.033] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Revised: 07/16/2018] [Accepted: 08/21/2018] [Indexed: 12/31/2022]
|
23
|
Litwinowicz R, Bartus M, Burysz M, Brzeziński M, Suwalski P, Kapelak B, Vuddanda V, Lakkireddy D, Lee RJ, Trabka R, Bartus K. Long term outcomes after left atrial appendage closure with the LARIAT device-Stroke risk reduction over five years follow-up. PLoS One 2018; 13:e0208710. [PMID: 30566961 PMCID: PMC6300408 DOI: 10.1371/journal.pone.0208710] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2018] [Accepted: 11/22/2018] [Indexed: 11/19/2022] Open
Abstract
Introduction Left atrial appendage closure (LAAC) with LARIAT offers an alternative to oral anticoagulation (OAC) for patients with atrial fibrillation. The aim of this study was to present long-term clinical outcomes of LAAC in these patients (AF). Material and methods A prospective, single-center study was performed in 139 patients undergoing LAAC with Lariat. Thromboembolic events, severe bleeding and mortality rate were recorded. The reduction in risk of thromboembolism and bleeding after LAAC was calculated. Results The mean CHADS2-score was 1.8 ± 1.0, mean CHA2DS2-VASc score was 2.9 ± 1.6 and HAS-BLED score was 3.1 ± 1.1. After 428.4 patient-years of follow-up (mean 4.2±1.0 years), the thromboembolism rate was 0.6% with a calculated thromboembolism risk reduction of 81%. The severe bleeding rate was 0.8%; calculated bleeding risk reduction was 78%. The overall mortality rate was 1.6%. Conclusions Long-term outcomes show that LAAC with Lariat is a safe and effective treatment for stroke prevention and bleeding risk reduction in AF patients with a high level of underlying risk.
Collapse
Affiliation(s)
- Radoslaw Litwinowicz
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University, John Paul II Hospital, Krakow, Poland
- * E-mail:
| | - Magdalena Bartus
- Departament of Pharmacology, Jagiellonian University, Krakow, Poland
| | - Marian Burysz
- Department of Cardiac Surgery, Regional Specialist Hospital, Grudziadz, Poland
| | - Maciej Brzeziński
- Department of Cardiac and Vacsular Surgery, Medical University of Gdansk, Gdansk, Poland
| | - Piotr Suwalski
- Department of Cardiac Surgery, Central Clinical Hospital of Ministry of Interior, Warsaw, Poland
| | - Boguslaw Kapelak
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University, John Paul II Hospital, Krakow, Poland
| | - Venkat Vuddanda
- Warren Alpert School of Medicine, Brown University, Harvard Medical School, Boston MA, United States of America
| | - Dhanunjaya Lakkireddy
- Division of Cardiovascular Diseases, Cardiovascular Research Institute, University of Kansas, Kansas City, KS, United States of America
| | - Randall J. Lee
- Department of Medicine, Division of Cardiac Electrophysiology, University of California San Francisco, San Francisco, CA, United States of America
- Cardiovascular Research Institute, Institute for Regeneration Medicine, University of California San Francisco, San Francisco, CA, United States of America
| | - Rafal Trabka
- Departament of Rehabilitation, Jagiellonian University, Krakow, Poland
| | - Krzysztof Bartus
- Department of Cardiovascular Surgery and Transplantology, Jagiellonian University, John Paul II Hospital, Krakow, Poland
| |
Collapse
|
24
|
Schellinger PD, Tsivgoulis G, Steiner T, Köhrmann M. Percutaneous Left Atrial Appendage Occlusion for the Prevention of Stroke in Patients with Atrial Fibrillation: Review and Critical Appraisal. J Stroke 2018; 20:281-291. [PMID: 30309224 PMCID: PMC6186917 DOI: 10.5853/jos.2018.02537] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2018] [Accepted: 09/12/2018] [Indexed: 12/27/2022] Open
Abstract
The authors review the current status of percutaneous left atrial appendage (LAA) occlusion therapy in patients with atrial fibrillation with the goal to prevent ischemic stroke and systemic embolism and to reduce oral anticoagulation associated bleeding. While we cover the historical and also surgical background, and all tested devices, the main focus rests on the single currently U.S. Food and Drug Administration (FDA) approved LAA occluder, the WATCHMAN device, and its approval process. The authors also give a critical appraisal beyond the review of mere facts, trying to put the current data into perspective.
Collapse
Affiliation(s)
- Peter D Schellinger
- Department of Neurology and Neurogeriatry, Johannes Wesling Medical Center Minden, University Clinic RUB, Minden, Germany
| | - Georgios Tsivgoulis
- Second Department of Neurology, Attikon University Hospital, National and Kapodistrian University of Athens, Athens, Greece.,Department of Neurology, University of Tennessee Health Sciences Center, Memphis, TN, USA
| | - Thorsten Steiner
- Department of Neurology, Frankfurt Hoechst Hospital, Frankfurt, Germany.,Department of Neurology, Heidelberg University Hospital, Heidelberg, Germany
| | - Martin Köhrmann
- Department of Neurology, Essen University Hospital, Essen, Germany
| |
Collapse
|
25
|
Fink T, Schlüter M, Tilz RR, Heeger CH, Lemes C, Maurer T, Reissmann B, Rottner L, Santoro F, Mathew S, Rillig A, Ouyang F, Kuck KH, Metzner A. Acute and long-term outcomes of epicardial left atrial appendage ligation with the second-generation LARIAT device: a high-volume electrophysiology center experience. Clin Res Cardiol 2018; 107:1139-1147. [DOI: 10.1007/s00392-018-1288-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Accepted: 05/30/2018] [Indexed: 10/14/2022]
|
26
|
Gupta D, Masoud A, Bartoletti S. The Authors’ reply. BRITISH HEART JOURNAL 2018. [DOI: 10.1136/heartjnl-2017-312829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
27
|
The Role of the Left Atrial Appendage in Stroke and Arrhythmia Provocation. CURRENT CARDIOVASCULAR RISK REPORTS 2018. [DOI: 10.1007/s12170-018-0576-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|