1
|
Pinsker BL, Moore JP, Bashore TM, Krasuski RA. Permanent Cardiac Pacing in the Fontan Population: A Contemporary Review of Indications, Approaches, and Outcomes. JACC. ADVANCES 2025; 4:101667. [PMID: 40117698 PMCID: PMC11976253 DOI: 10.1016/j.jacadv.2025.101667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2024] [Revised: 01/20/2025] [Accepted: 02/14/2025] [Indexed: 03/23/2025]
Abstract
Following the Fontan operation, electrophysiologic abnormalities requiring pacemaker implantation are common, consisting of sinus node dysfunction, complete atrioventricular block, and electromechanical dyssynchrony. Pacemaker implantation in this population can be challenging, as transvenous access to the cardiac chambers is often limited and may increase the risk of thromboembolism. Consequently, epicardial lead placement continues to be the default approach at most centers. Furthermore, permanent cardiac pacing has been associated with poor outcomes in this population (including an increased need for cardiac transplantation and death), even though it may be, depending on the approach, of great benefit for many individuals. Fortunately, improved understanding of the differential effects of cardiac pacing and novel approaches related to implantation have been developed and have increased their application to a growing number of patients. This review highlights the indications for pacing, methods to facilitate lead implantation, and associated outcomes in Fontan patients requiring permanent cardiac pacing.
Collapse
Affiliation(s)
- Bret L Pinsker
- Department of Medicine, Duke University Medical Center, Durham, North Carolina, USA.
| | - Jeremy P Moore
- Ahmanson/UCLA Adult Congenital Heart Disease Program, UCLA Health System, Los Angeles, California, USA
| | - Thomas M Bashore
- Department of Cardiovascular Medicine, Duke University Medical Center, Durham, North Carolina, USA
| | - Richard A Krasuski
- Department of Cardiovascular Medicine, Duke University Medical Center, Durham, North Carolina, USA
| |
Collapse
|
2
|
Bohn C, Schaeffer T, Staehler H, Heinisch PP, Piber N, Cuman M, Hager A, Ewert P, Hörer J, Ono M. Brady-arrhythmias requiring permanent pacemaker implantation during and after staged Fontan palliation. Cardiol Young 2024; 34:524-530. [PMID: 37496165 DOI: 10.1017/s1047951123002500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 07/28/2023]
Abstract
BACKGROUND Brady-arrhythmia requiring pacemaker implantation remains one of the Fontan-specific complications before and after total cavopulmonary connection. METHODS A retrospective analysis of 620 patients who underwent total cavopulmonary connection between 1994 and 2021 was performed to evaluate the incidence of brady-arrhythmia and the outcomes after pacemaker implantation. Factors associated with the onset of brady-arrhythmia were identified. RESULTS A total of 52 patients presented with brady-arrhythmia and required pacemaker implantation. Diagnosis included 16 sinus node dysfunctions, 29 atrioventricular blocks, and 7 junctional escape rhythms. Pacemaker implantation was performed before total cavopulmonary connection (n = 16), concomitant with total cavopulmonary connection (n = 8), or after total cavopulmonary connection (n = 28, median 1.8 years post-operatively). Freedom from pacemaker implantation following total cavopulmonary connection at 10 years was 92%. Twelve patients needed revision of electrodes due to lead dysfunction (n = 9), infections (n = 2), or dislocation (n = 1). Lead energy thresholds were stable, and freedom from pacemaker lead revision at 10 years after total cavopulmonary connection was 78%. Congenitally corrected transposition of the great arteries (odds ratio: 6.6, confidence interval: 2.0-21.5, p = 0.002) was identified as a factor associated with pacemaker implantation before total cavopulmonary connection. Pacemaker rhythms for Fontan circulation were not a risk factor for survival (p = 0.226), protein-losing enteropathy/plastic bronchitis (p = 0.973), or thromboembolic complications (p = 0.424). CONCLUSIONS In our cohort of patients following total cavopulmonary connection, freedom from pacemaker implantation at 10 years was 92% and stable atrial and ventricular lead energy thresholds were observed. Congenitally corrected transposition of the great arteries was at increased risk for pacemaker implantation before total cavopulmonary connection. Having a pacemaker in the Fontan circulation had no adverse effect on survival, protein-losing enteropathy/plastic bronchitis, or thromboembolic complications.
Collapse
Affiliation(s)
- Cornelius Bohn
- Department of Congenital and Pediatric Heart Surgery, German Heart Center Munich, Technische Universität, Munich, Germany
- University Hospital of Munich, Ludwig-Maximilians-Universität, Munich, Germany
| | - Thibault Schaeffer
- Department of Congenital and Pediatric Heart Surgery, German Heart Center Munich, Technische Universität, Munich, Germany
- University Hospital of Munich, Ludwig-Maximilians-Universität, Munich, Germany
| | - Helena Staehler
- Department of Congenital and Pediatric Heart Surgery, German Heart Center Munich, Technische Universität, Munich, Germany
- University Hospital of Munich, Ludwig-Maximilians-Universität, Munich, Germany
| | - Paul Philipp Heinisch
- Department of Congenital and Pediatric Heart Surgery, German Heart Center Munich, Technische Universität, Munich, Germany
- University Hospital of Munich, Ludwig-Maximilians-Universität, Munich, Germany
| | - Nicole Piber
- Department of Cardiovascular Surgery, German Heart Center Munich, Technische Universität München, Munich, Germany
| | - Magdalena Cuman
- Department of Congenital Heart Disease and Pediatric Cardiology, German Heart Center Munich, Technische Universität München, Munich, Germany
| | - Alfred Hager
- Department of Congenital Heart Disease and Pediatric Cardiology, German Heart Center Munich, Technische Universität München, Munich, Germany
| | - Peter Ewert
- Department of Congenital Heart Disease and Pediatric Cardiology, German Heart Center Munich, Technische Universität München, Munich, Germany
| | - Jürgen Hörer
- Department of Congenital and Pediatric Heart Surgery, German Heart Center Munich, Technische Universität, Munich, Germany
- University Hospital of Munich, Ludwig-Maximilians-Universität, Munich, Germany
| | - Masamichi Ono
- Department of Congenital and Pediatric Heart Surgery, German Heart Center Munich, Technische Universität, Munich, Germany
- University Hospital of Munich, Ludwig-Maximilians-Universität, Munich, Germany
| |
Collapse
|
3
|
Mondésert B, Moore JP, Khairy P. Cardiac Implantable Electronic Devices in the Fontan Patient. Can J Cardiol 2022; 38:1048-1058. [PMID: 35588949 DOI: 10.1016/j.cjca.2022.04.024] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Revised: 04/18/2022] [Accepted: 04/19/2022] [Indexed: 12/22/2022] Open
Abstract
As a result of remarkable progress in operative techniques and cardiology care during childhood, Fontan patients continue to age and require team-based multidisciplinary expertise to manage complications encountered in adulthood. They face particular challenges in terms of altered hemodynamic stressors, cardiac and hepatic failure, and arrhythmias. Arrhythmias in Fontan patients are highly prevalent and associated with underlying anatomy, surgical technique, and postoperative sequelae. Diagnostic tools, treatments, and device strategies for arrhythmias in Fontan patients should be adapted to the specific anatomy, type of surgical repair, and clinical status. Great strides in our understanding of arrhythmia mechanisms, options and techniques to obtain access to relevant cardiac structures, and application of both old and new technologies have contributed to improving cardiac implantable electronic device (CIED) therapies for this unique population. In this state-of-the-art review, we discuss the various arrhythmias encountered in Fontan patients, their diagnosis, and options for treatment and prevention, with a focus on CIEDs. Throughout, access challenges particular to the Fontan circulation are considered. Recently developed technologies, such as the sub-cutaneous implantable cardioverter defibrillator carry the potential to be transformative but require awareness of Fontan-specific issues. Moreover, new leadless pacing technology represents a promising strategy that may soon become applicable to Fontan patients with sinus node dysfunction. CIEDs are essential tools in managing Fontan patients but the complex clinical scenarios that arise in this patient population are among the most challenging for the congenital electrophysiologist.
Collapse
Affiliation(s)
- Blandine Mondésert
- Adult Congenital Heart Disease Center, Montreal Heart Institute, Medicine Department, Université de Montréal, Montreal, Canada.
| | - Jeremy P Moore
- Division of Cardiology, Department of Medicine, Ahmanson/UCLA Adult Congenital Heart Disease Center, Los Angeles, CA; UCLA Cardiac Arrhythmia Center, UCLA Health System, Los Angeles, CA; Division of Cardiology, Department of Pediatrics, UCLA Health System, Los Angeles, CA
| | - Paul Khairy
- Adult Congenital Heart Disease Center, Montreal Heart Institute, Medicine Department, Université de Montréal, Montreal, Canada
| |
Collapse
|