1
|
Macherey S, Meertens M, Mauri V, Frerker C, Adam M, Baldus S, Schmidt T. Meta-Analysis of Stroke and Mortality Rates in Patients Undergoing Valve-in-Valve Transcatheter Aortic Valve Replacement. J Am Heart Assoc 2021; 10:e019512. [PMID: 33682426 PMCID: PMC8174195 DOI: 10.1161/jaha.120.019512] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background During the past decade, the use of transcatheter aortic valve replacement (TAVR) was extended beyond treatment‐naïve patients and implemented for treatment of degenerated surgical bioprosthetic valves. Selection criteria for either valve‐in‐valve (viv) TAVR or redo surgical aortic valve replacement are not well established, and decision making on the operative approach still remains challenging for the interdisciplinary heart team. Methods and Results This review was intended to analyze all studies on viv‐TAVR focusing on short‐ and mid‐term stroke and mortality rates compared with redo surgical aortic valve replacement or native TAVR procedures. A structured literature search and review process led to 1667 potentially relevant studies on July 1, 2020. Finally, 23 studies fulfilled the inclusion criteria for qualitative analysis. All references were case series either with or without propensity score matching and registry analyses. Quantitative synthesis of data from 8509 patients revealed that viv‐TAVR is associated with mean 30‐day stroke and mortality rates of 2.2% and 4.2%, respectively. Pooled data analysis showed no significant differences in 30‐day stroke rate, 30‐day mortality, and 1‐year mortality between viv‐TAVR and comparator treatment (native TAVR [n=11 804 patients] or redo surgical aortic valve replacement [n=498 patients]). Conclusions This review is the first one comparing the risk for stroke and mortality rates in viv‐TAVR procedures with native TAVR approach and contributes substantial data for the clinical routine. Moreover, this systematic review is the most comprehensive analysis on ischemic cerebrovascular events and early mortality in patients undergoing viv‐TAVR. In this era with increasing numbers of bioprosthetic valves used in younger patients, viv‐TAVR is a suitable option for the treatment of degenerated bioprostheses.
Collapse
Affiliation(s)
- Sascha Macherey
- Department III of Internal Medicine University Hospital of Cologne Cologne Germany
| | - Max Meertens
- Department III of Internal Medicine University Hospital of Cologne Cologne Germany
| | - Victor Mauri
- Department III of Internal Medicine University Hospital of Cologne Cologne Germany
| | - Christian Frerker
- Department III of Internal Medicine University Hospital of Cologne Cologne Germany
| | - Matti Adam
- Department III of Internal Medicine University Hospital of Cologne Cologne Germany
| | - Stephan Baldus
- Department III of Internal Medicine University Hospital of Cologne Cologne Germany
| | - Tobias Schmidt
- Department III of Internal Medicine University Hospital of Cologne Cologne Germany
| |
Collapse
|
2
|
Lee HA, Chou AH, Wu VCC, Chen DY, Lee HF, Lee KT, Chu PH, Cheng YT, Chang SH, Chen SW. Balloon-expandable versus self-expanding transcatheter aortic valve replacement for bioprosthetic dysfunction: A systematic review and meta-analysis. PLoS One 2020; 15:e0233894. [PMID: 32479546 PMCID: PMC7263630 DOI: 10.1371/journal.pone.0233894] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Accepted: 05/14/2020] [Indexed: 01/11/2023] Open
Abstract
BACKGROUND Transcatheter aortic valve-in-valve (VIV) procedure is a safe alternative to conventional reoperation for bioprosthetic dysfunction. Balloon-expandable valve (BEV) and self-expanding valve (SEV) are the 2 major types of devices used. Evidence regarding the comparison of the 2 valves remains scarce. METHODS A systematic review and meta-analysis was conducted to compare the outcomes of BEV and SEV in transcatheter VIV for aortic bioprostheses dysfunction. A computerized search of Medline, PubMed, Embase, and Cochrane databases was performed. English-language journal articles reporting SEV or BEV outcomes of at least 10 patients were included. RESULTS In total, 27 studies were included, with 2,269 and 1,671 patients in the BEV and SEV groups, respectively. Rates of 30-day mortality and stroke did not differ significantly between the 2 groups. However, BEV was associated with significantly lower rates of postprocedural permanent pacemaker implantation (3.8% vs. 12%; P < 0.001). Regarding echocardiographic parameters, SEV was associated with larger postprocedural effective orifice area at 30 days (1.53 cm2 vs. 1.23 cm2; P < 0.001) and 1 year (1.55 cm2 vs. 1.22 cm2; P < 0.001). CONCLUSIONS For patients who underwent transcatheter aortic VIV, SEV was associated with larger postprocedural effective orifice area but higher rates of permanent pacemaker implantation. These findings provide valuable information for optimizing device selection for transcatheter aortic VIV.
Collapse
Affiliation(s)
- Hsiu-An Lee
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan
- Division of Cardiovascular Surgery, Department of Surgery, Chang Bing Show Chwan Memorial Hospital, Changhua, Taiwan
| | - An-Hsun Chou
- Department of Anesthesiology, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan
| | - Victor Chien-Chia Wu
- Department of Cardiology, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan
| | - Dong-Yi Chen
- Department of Cardiology, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan
| | - Hsin-Fu Lee
- Department of Cardiology, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan
| | - Kuang-Tso Lee
- Department of Cardiology, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan
| | - Pao-Hsien Chu
- Department of Cardiology, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan
| | - Yu-Ting Cheng
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan
| | - Shang-Hung Chang
- Department of Cardiology, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan
| | - Shao-Wei Chen
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan
- Center for Big Data Analytics and Statistics, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan City, Taiwan
- * E-mail:
| |
Collapse
|
3
|
Stankowski T, Aboul-Hassan SS, Seifi Zinab F, Herwig V, Stępiński P, Grimmig O, Just S, Harnath A, Muehle A, Fritzsche D, Perek B. Femoral transcatheter valve-in-valve implantation as alternative strategy for failed aortic bioprostheses: A single-centre experience with long-term follow-up. Int J Cardiol 2020; 306:25-34. [DOI: 10.1016/j.ijcard.2020.02.035] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2019] [Revised: 01/15/2020] [Accepted: 02/12/2020] [Indexed: 02/02/2023]
|