1
|
Karangelis D, Stougiannou TM, Christodoulou KC, Bartolozzi H, Malafi ME, Mitropoulos F, Mikroulis D, Bena M. Hybrid Aortic Arch Replacement with Frozen Elephant Trunk (FET) Technique: Surgical Considerations, Pearls, and Pitfalls. J Clin Med 2024; 13:7075. [PMID: 39685533 DOI: 10.3390/jcm13237075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2024] [Revised: 11/12/2024] [Accepted: 11/21/2024] [Indexed: 12/18/2024] Open
Abstract
The involvement of the aortic arch in thoracic aortic aneurysms (TAA), or acute aortic dissections (AAD), represents a challenging clinical entity, mandating a meticulous surgical plan, tailored to each individual case. The advent of endovascular techniques and the introduction of modern arch protheses have led to the implementation of the frozen elephant trunk (FET) technique. This one-step hybrid operation consists of a total aortic arch replacement combined with an antegrade delivery of a stent-graft for the descending aorta, which acts as a proximal landing zone facilitating a potential distal endovascular reintervention. In this manner, this technique addresses acute and chronic arch disease with an acceptable morbidity and mortality. Several FET prosthetic devices are available on the global market and have exhibited favourable outcomes, although with some disadvantages in complex cases; similarly, the hybrid procedure described in this review has also been associated with complications, such as coagulopathy and neurological and graft-related events. The purpose of this review is to thus provide key insights into successful hybrid aortic arch replacements and to discuss useful tips and relevant considerations regarding its use.
Collapse
Affiliation(s)
- Dimos Karangelis
- Department of Cardiothoracic Surgery, Democritus University of Thrace University General Hospital, 68100 Alexandroupolis, Greece
| | - Theodora M Stougiannou
- Department of Cardiothoracic Surgery, Democritus University of Thrace University General Hospital, 68100 Alexandroupolis, Greece
| | - Konstantinos C Christodoulou
- Center for Thrombosis and Hemostasis (CTH), University Medical Center of the Johannes Gutenberg University, 55131 Mainz, Germany
| | - Henri Bartolozzi
- Department of Cardiothoracic Surgery, Democritus University of Thrace University General Hospital, 68100 Alexandroupolis, Greece
| | - Maria Eleni Malafi
- Department of Cardiothoracic Surgery, Democritus University of Thrace University General Hospital, 68100 Alexandroupolis, Greece
| | - Fotios Mitropoulos
- Department of Adult and Congenital Cardiac Surgery, Mitera Hospital, 15123 Athens, Greece
| | - Dimitrios Mikroulis
- Department of Cardiothoracic Surgery, Democritus University of Thrace University General Hospital, 68100 Alexandroupolis, Greece
| | - Martin Bena
- Department of Cardiac Surgery, CINRE Hospital, 84103 Bratislava, Slovakia
| |
Collapse
|
2
|
Dai L, Zhou C, Zhang L, Qiu J, Liu S, Qiu J, Zhao R, Xie E, Song J, Yu C. Safety and effectiveness of the sutureless integrated stented graft prosthesis in an animal model. Heliyon 2024; 10:e30323. [PMID: 38711632 PMCID: PMC11070854 DOI: 10.1016/j.heliyon.2024.e30323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 03/02/2024] [Accepted: 04/23/2024] [Indexed: 05/08/2024] Open
Abstract
BACKGROUND Prolonged circulatory arrest time is an independent risk factor for postoperative adverse events of type A aortic dissection (TAAD) surgery. Further reduction of the circulatory arrest time is essential to improve surgical outcomes. This study aimed to evaluate the safety and effectiveness of the novel Sutureless Integrated Stented (SIS) graft prosthesis in an animal experiment. MATERIALS AND METHODS Straight type of the SIS graft prosthesis was implanted into the descending aorta of 10 adult male sheep, and the use of the device was scored on a scale of 1-10. Aortic digital subtraction angiography (DSA) was performed at 4, 14, and 26 weeks to investigate the prostheses. After 26 weeks, the animals were sacrificed for histological analysis. RESULTS The immediate success rate of the surgery was 100 %, and the overall mean score of the use of the device was 9.65 ± 0.99. Three animals died from non-device-related causes during follow-up. Aortic DSA showed filling defects in 5 animals. Histological analysis revealed that all prostheses were intact. Except for 2 early deaths, the other 8 prostheses were endothelialized with mild inflammation, foreign body reactions, and intimal fibrosis. The mean cross-sectional area of the sutureless region was reduced by 26.4 % (range, 1.3-39.1 %). CONCLUSIONS The safety and effectiveness of the novel SIS graft prosthesis were acceptable, and the delivery system exhibited a promising performance. Using the SIS graft prosthesis in TAAD surgery was expected to simplify the procedures and shorten the circulatory arrest time. Further large-scale clinical trials are required to verify these findings.
Collapse
Affiliation(s)
- Lu Dai
- Department of Aortic Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College/National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Chenyu Zhou
- Department of Aortic Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College/National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Liang Zhang
- Department of Aortic Surgery, Anhui Chest Hospital, Hefei, Anhui, China
| | - Juntao Qiu
- Department of Aortic Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College/National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Shen Liu
- Department of Cardiac Surgery, Peking University International Hospital, Peking University Eighth Clinical Medical School, Beijing, China
| | - Jiawei Qiu
- Department of Aortic Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College/National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Rui Zhao
- Department of Aortic Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College/National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Enzehua Xie
- Department of Aortic Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College/National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Jian Song
- Department of Aortic Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College/National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| | - Cuntao Yu
- Department of Aortic Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College/National Clinical Research Center for Cardiovascular Diseases, Beijing, China
| |
Collapse
|
3
|
Jubouri M, Kayali F, Agbobu T, Tahhan O, Moothathamby T, Abdulwahab ER, Velayudhan B, Mohammed I, Bashir M. Thoraflex Hybrid Prosthesis (THP): the profile. Expert Rev Med Devices 2024; 21:165-177. [PMID: 38431273 DOI: 10.1080/17434440.2024.2326539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Accepted: 02/29/2024] [Indexed: 03/05/2024]
Abstract
INTRODUCTION With the incidence of thoracic aortic disease on the rise, total arch replacement (TAR) with frozen elephant trunk (FET) remains the gold-standard management strategy due to optimal results. Several FET devices exist commercially on the global market. However, the mainstay and most commonly used and reported device is the Thoraflex Hybrid Prosthesis (THP), with several recent reports suggesting its superiority. AREAS COVERED This review aims to collate and summarize the evidence in the literature on the clinical outcomes of TAR with FET using THP, with a focus on mortality, neurological complications, endoleak, distal stent-induced new entry (dSINE), aortic remodeling, coagulopathy, and graft kinking. In addition, the design features of THP is discussed, and an overview of market competitors is also highlighted. EXPERT OPINION THP consistently demonstrates its effectiveness in treating complex thoracic aortic pathology through favorable clinical outcomes, which can be attributed to its unique and innovative design. Rates of early mortality ranged 0.6-14.2%, neurological complications 0-25%, endoleak 0-8.4% and dSINE 0-14.5%, with minimal incidence of graft kinking and coagulopathy. Aortic remodeling is favorable and comparable to competitors. All this evidence solidifies THP as the leading FET device, particularly when combined with appropriate patient selection and surgical planning.
Collapse
Affiliation(s)
- Matti Jubouri
- Hull York Medical School, University of York, York, UK
| | - Fatima Kayali
- University Hospitals Sussex NHS Foundation Trust, Sussex, UK
| | | | - Owais Tahhan
- Aston Medical School, Aston University, Birmingham, UK
| | - Thurkga Moothathamby
- Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London, UK
| | - Eyad R Abdulwahab
- University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK
| | - Bashi Velayudhan
- Institute of Cardiac and Aortic Disorders (ICAD), SRM Institutes for Medical Science (SIMS Hospital), Chennai, Tamil Nadu, India
| | - Idhrees Mohammed
- Institute of Cardiac and Aortic Disorders (ICAD), SRM Institutes for Medical Science (SIMS Hospital), Chennai, Tamil Nadu, India
| | - Mohamad Bashir
- Neurovascular Research Laboratory, Faculty of Life Sciences and Education, University of South Wales, Pontypridd, UK
| |
Collapse
|
4
|
Jakob H, Leins T, Avci-Adali M, Schlensak C, Wendt D, Mehta Y, Thielmann M, Görlinger K, Song SW, Tsagakis K. Standardized in vitro bleeding tests in a non-coated novel hybrid prosthesis for frozen elephant trunk demonstrates minimal oozing during full heparinization, supported by clinical data. Front Cardiovasc Med 2023; 10:1303816. [PMID: 38155987 PMCID: PMC10752973 DOI: 10.3389/fcvm.2023.1303816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 11/23/2023] [Indexed: 12/30/2023] Open
Abstract
Introduction Recent reports have questioned the blood impermeability of the novel frozen elephant trunk (FET) device E-vita Open NEO© (EO-NEO). Therefore, standardized in vitro bleeding tests using porcine heparinized blood were performed, as well as stress testing on the blood tightness of the collar suture line, to investigate this observation. Material and methods EO-NEO prostheses were examined in vitro for blood permeability in three test series. Initially, antegrade perfusion with heparinized porcine blood [activated clotting time (ACT) of 500 s, with a 60 min duration] was performed, followed by ante/retrograde testing via the EO-NEO side port. Testing of the collar suture line under a tension of 10 Newton (N) within a suspension device (blood pressure 120 mmHg, ACT of 560 s, 1 min duration) was carried out with the suture material force fiber white (FFWs) yarn, using standard fixation (5 stitches/cm), FFWh yarn in hemostatic fixation (15 stitches/cm), and flow weave yarn (FWYh). Results Blood permeability testing of EO-NEO through the prosthetic lumen or via the side port demonstrated minor leakage without statistical difference between the standard and hemostatic suture lines or suture materials used, or positioning on the crimped or tapered portion (p > 0.05). The specific collar anastomosis testing demonstrated leakage volumes of 140 ml/min for FFWs vs. 16 ml/min for FFWh (p = 0.02), vs. 9 ml/min with the FWYh (p = 0.01). Conclusion Different blood leakage tests showed minimal oozing and no difference in blood loss through the fabric and different collar suture lines, but unphysiological pressurized retrograde perfusion of the collar region showed significantly less leakage using FWYh and FFWh, prompting production modification of EO-NEO. Clinical results confirmed low blood loss using this novel FET device.
Collapse
Affiliation(s)
- Heinz Jakob
- Diagnosticum Mülheim, Mülheim, Germany
- Department of Thoracic- and Cardiovascular Surgery, West German Heart and Vascular Center, Essen, Germany
| | - Timo Leins
- Medira GmbH, Balingen, Germany
- JOTEC-Artivion, Hechingen, Germany
| | - Meltem Avci-Adali
- Department of Thoracic and Cardiovascular Surgery, University Hospital Tuebingen, Tuebingen, Germany
| | - Christian Schlensak
- Department of Thoracic and Cardiovascular Surgery, University Hospital Tuebingen, Tuebingen, Germany
| | - Daniel Wendt
- Department of Thoracic- and Cardiovascular Surgery, West German Heart and Vascular Center, Essen, Germany
- CytoSorbents Europe, Berlin, Germany
| | - Yatin Mehta
- Medanta Institute of Critical Care and Anesthesiology, Medanta - The Medicity, Gurgaon, India
| | - Matthias Thielmann
- Department of Thoracic- and Cardiovascular Surgery, West German Heart and Vascular Center, Essen, Germany
| | | | - Suk-Won Song
- Department of Thoracic and Cardiovascular Surgery, College of Medicine, Ewha Womans University, Seoul, Republic of Korea
| | - Konstantinos Tsagakis
- Department of Thoracic- and Cardiovascular Surgery, West German Heart and Vascular Center, Essen, Germany
| |
Collapse
|
5
|
Al-Tawil M, Jubouri M, Tan SZ, Bailey DM, Williams IM, Mariscalco G, Piffaretti G, Chen EP, Velayudhan B, Mohammed I, Bashir M. Thoraflex Hybrid vs. AMDS: To replace the arch or to stent it in type A aortic dissection? Asian Cardiovasc Thorac Ann 2023; 31:596-603. [PMID: 36560846 DOI: 10.1177/02184923221147442] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
BACKGROUND Acute type A aortic dissection (ATAAD) is a life-threatening medical emergency that requires urgent surgical intervention. The mainstay surgical approach to treating ATAAD with aortic arch involvement is total arch replacement (TAR). The frozen elephant trunk (FET) procedure involves TAR with hybrid endovascular stenting of the DTA in a single step using a hybrid prosthesis (HP). The prime example of a FET HP is Thoraflex Hybrid Prosthesis (THP). Another treatment option is the novel Ascyrus Medical Dissection Stent (AMDS) that is deployed as a non-covered stent along with the aortic arch as an adjunct to prior hemi-arch replacement. AIMS This comparative review highlights the clinical applications and outcomes of THP and AMDS in the treatment of ATAAD and discusses the main differences between both approaches. METHODS A comprehensive literature search was conducted using multiple electronic databases including PubMed, Google Scholar, Ovid, Scopus and Embase. RESULTS TAR with FET can be considered the superior approach to managing ATAAD with arch involvement relative to AMDS with hemi-arch replacement due to more optimal clinical outcomes. Upon comprehensively searching the literature, early mortality was substantially lower with FET ranging from 0-11% compared to 12.5-18.7% using AMDS, with more favourable long-term survival. The incidence of kidney injury and new stroke post-FET ranged from 3-20% and 5-16%, and 11-37.5% and 0-18.8% following AMDS implantation. However, evidence supporting the use of AMDS is extremely limited. Meanwhile, TAR with FET is a well-established and well-described procedure for ATAAD repair. CONCLUSION Despite the novel nature of AMDS, its clinical safety and effectiveness are yet to be proven. In conclusion, THP remains the best evidenced-based approach to treat ATAAD in this era.
Collapse
Affiliation(s)
| | - Matti Jubouri
- Hull York Medical School, University of York, York, UK
| | - Sven Zcp Tan
- Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London, UK
| | - Damian M Bailey
- Neurovascular Research Laboratory, Faculty of Life Sciences and Education, University of South Wales, Pontypridd, UK
| | - Ian M Williams
- Department of Vascular Surgery, University Hospital of Wales, Cardiff, UK
| | - Giovanni Mariscalco
- Department of Cardiac Surgery, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester, UK
| | - Gabrielle Piffaretti
- Vascular Surgery - Department of Medicine and Surgery, University of Insubria School of Medicine, Varese, Italy
| | - Edward P Chen
- Division of Cardiovascular and Thoracic Surgery, Duke University Medical Center, DUMC 3442, Durham, NC, USA
| | - Bashi Velayudhan
- Institute of Cardiac and Aortic Disorders (ICAD), SRM Institutes for Medical Science (SIMS Hospital), Chennai, Tamil Nadu, India
| | - Idhrees Mohammed
- Institute of Cardiac and Aortic Disorders (ICAD), SRM Institutes for Medical Science (SIMS Hospital), Chennai, Tamil Nadu, India
| | - Mohamad Bashir
- Vascular and Endovascular Surgery, Velindre University NHS Trust, Health Education and Improvement Wales, Cardiff, UK
| |
Collapse
|
6
|
Tan SZCP, Mohammed I, Bashir M. Frozen Elephant Trunk Sizing: A 30,000-Feet Perspective with Thoraflex Hybrid Stent Graft. AORTA (STAMFORD, CONN.) 2022; 10:182-190. [PMID: 36521811 PMCID: PMC9754870 DOI: 10.1055/s-0042-1756667] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
There is currently no standard, evidence-based approach for sizing the Thoraflex Hybrid prosthesis in frozen elephant trunk surgery. We present regional data on 906 Thoraflex grafts implanted in the United Kingdom between December 2012 and August 2021 to emphasize the heterogeneity in sizing practices and evaluate the impact this may have on clinical outcomes. Highlighting this heterogeneity will help develop an evidence-based approach to prosthesis sizing, thereby aiding decision-making for arch repair.
Collapse
Affiliation(s)
- Sven Z. C. P. Tan
- Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London, United Kingdom
| | - Idhrees Mohammed
- Institute of Cardiac and Aortic Disorders, SRM Institutes for Medical Science (SIMS Hospital), Chennai, Tamil Nadu, India
| | - Mohamad Bashir
- Institute of Cardiac and Aortic Disorders, SRM Institutes for Medical Science (SIMS Hospital), Chennai, Tamil Nadu, India,Heart Valve Disease Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran,Department of Vascular and Endovascular Surgery, Velindre University National Health Service Trust, Health and Education Improvement Wales, Wales, United Kingdom,Address for correspondence Mohamad Bashir, MD, PhD, MRCS Department of Vascular and Endovascular Surgery, Velindre University NHS Trust, Health and Education Improvement WalesWales CF15 7QQUnited Kingdom
| |
Collapse
|
7
|
Mohammed I, Tan SZ, Jubouri M, Shaw M, Bashir M. Institutional practice in sizing of the hybrid prosthesis in frozen elephant trunk surgery. THE JOURNAL OF CARDIOVASCULAR SURGERY 2022; 63:406-414. [PMID: 35343661 DOI: 10.23736/s0021-9509.22.12303-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
BACKGROUND The frozen elephant trunk (FET) technique for total arch replacement (TAR) is widely used for repair of aortic arch dissections and aneurysms. Despite its widespread adoption, there are no international or regional guidelines for the sizing of FET prostheses in TAR. We seek to highlight the heterogeneity thereof and pave the way for evidence-based guidelines to advise FET prosthesis sizing in TAR. METHODS An online questionnaire was sent to 22 specialist aortic surgeons from 13 different countries across North America, Europe, Asia, and Australia, inquiring about each surgeon's approach to FET prosthesis sizing. The results were then pooled for frequency analysis. RESULTS All 22 surgeons responded to the questionnaire. Zone 2 is preferred implantation zone for AAD, CAD, and TAA (selected by 72.7%, 72.7%, and 68.2% respectively). The maximal diameter of the true lumen in the DTA is the most common index measurement for AAD and CAD (40.9% and 59.1%, respectively). Stent-graft diameters equal to the index measurement is the most common approach for AAD and CAD (77.3% and 45.5%, respectively) while 59.1% of surgeons oversize the index diameter by 10% for TAA; 100 mm is the preferred length for 50.0%, 27.3%, and 40.9% of surgeons in AAD, CAD, and TAA respectively. CONCLUSIONS There is considerable heterogeneity in sizing practices for FET prostheses internationally, with variable evidence for its impact on clinical outcomes. This issue would be aided by the development of evidence-based guidelines to inform clinical decision making.
Collapse
Affiliation(s)
- Idhrees Mohammed
- Institute of Cardiac and Aortic Disorders (ICAD), SRM Institutes for Medical Sciences, SIMS Hospital, Chennai, India
| | - Sven Z Tan
- Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London, UK
| | - Matti Jubouri
- Hull-York Medical School, University of York, York, UK
| | - Matthew Shaw
- Research Unit, Liverpool Heart and Chest Hospital NHS Foundation Trust, Liverpool, UK
| | - Mohamad Bashir
- Institute of Cardiac and Aortic Disorders (ICAD), SRM Institutes for Medical Sciences, SIMS Hospital, Chennai, India -
- Vascular and Endovascular Surgery, Velindre University NHS Trust, Health Education and Improvement Wales, Cardiff, UK
| |
Collapse
|
8
|
Kayali F, Qutaishat S, Jubouri M, Chikhal R, Tan SZCP, Bashir M. Kinking of Frozen Elephant Trunk Hybrid Prostheses: Incidence, Mechanism, and Management. Front Cardiovasc Med 2022; 9:912071. [PMID: 35571190 PMCID: PMC9091648 DOI: 10.3389/fcvm.2022.912071] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Accepted: 04/06/2022] [Indexed: 01/10/2023] Open
Abstract
Introduction Kinking of the Frozen Elephant Trunk (FET) stent graft is one of the most devastating complications of the FET procedure. It can present post-operatively with reduced arterial pressures in the lower limbs and intermittent claudication. However, it can also be visualized intra-operatively by the surgeons. Unresolved kinking of the stent graft can result in intraluminal thrombus formation and subsequent multi-organ septic emboli. Aims The main scope of this review is to collate, summarize and present all the evidence in the literature on kinking of FET stent grafts. Methods We carried out a comprehensive literature search on multiple electronic databases including PubMed, EMBASE, Ovid, and Scopus to collate all research evidence on the incidence, mechanism, and management of FET graft kinking. Results Incidence of kinking is variable, ranging from 0% to 8% in the literature, with varying rates associated with each stent graft type. The Thoraflex HybridTM prosthesis seemed to be the most commonly used and superior graft, and out of all the 15 cases of kinking reported in the literature, 5 (33.3%) were associated with just the Frozenix graft which had the highest incidence. There are multiple theories regarding the mechanism of kinking, including the direction of blood flow, the length of the stent grafts used, and the position of the prosthesis in relation to the flexure of the aorta. Multiple reparative management techniques have been suggested in the literature and include total endovascular repair, open repair, balloon dilatation, and deploying a second stent graft. Conclusion Graft kinking is one of the most critical complications of the FET technique. Its life-threatening sequelae warrant appropriate follow-up of these patients post-operatively, in addition to time management if kinking is suspected. Given the limited evidence in the literature, future studies should incorporate graft kinking into their outcomes reporting.
Collapse
Affiliation(s)
- Fatima Kayali
- School of Medicine, University of Central Lancashire, Preston, United Kingdom
| | | | - Matti Jubouri
- Hull York Medical School, University of York, York, United Kingdom
| | - Rohan Chikhal
- Hull York Medical School, University of York, York, United Kingdom
| | - Sven Z C P Tan
- Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London, United Kingdom
| | - Mohamad Bashir
- Vascular & Endovascular Surgery, Velindre University NHS Trust, Health Education & Improvement Wales (HEIW), Cardiff, United Kingdom
| |
Collapse
|
9
|
Tan SZCP, Jubouri M, Mohammed I, Bashir M. What Is the Long-Term Clinical Efficacy of the Thoraflex™ Hybrid Prosthesis for Aortic Arch Repair? Front Cardiovasc Med 2022; 9:842165. [PMID: 35282343 PMCID: PMC8905287 DOI: 10.3389/fcvm.2022.842165] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Accepted: 01/03/2022] [Indexed: 01/02/2023] Open
Abstract
Background The widespread adoption of the frozen elephant trunk (FET) technique for total arch reconstruction (TAR) in aortic arch aneurysm and dissection has led to the development of numerous commercial single-piece FET devices, each with its own unique design features. One such device, Thoraflex™ Hybrid (Terumo Aortic, Glasgow, Scotland), has enjoyed widespread use since its introduction. We present and appraisal of its long-term clinical efficacy, based on international data. Materials and Methods Pre-, intra-, and postoperative data associated with Thoraflex™ Hybrid implantations for aortic arch dissection, aneurysm, and penetrating atherosclerotic ulcer (PAU) up to April 2019 was gathered and is presented herein. Follow-up data at discharge, 3-, 6-, 12-, 24-, 36-, 48-, 60-, 72-, and 84- months post-implantation are included. Results Data associated with 931 cases of Thoraflex™ Hybrid implantation are included. Mean age at implantation was 63 ± 12 years. 55% of patients included were male. Aortic dissection accounted for 48% (n = 464) of cases. Mean cardiopulmonary bypass and circulatory arrest durations were 202 +72 and 69 ± 50 min, respectively. 30-day mortality was 0.6% (n = 6), while overall mortality was 14 (1.5%). Freedom from adverse events at 84 months was 95% (n = 869). Postoperative complications included neurological deficit, multi-organ failure, cardiorespiratory compromise, and infection. Discussion Thoraflex™ Hybrid's unique design is advantageous in comparison to market alternatives. Our data is consistent with that reported in literature and suggests Thoraflex™ Hybrid is associated with favourable rates of mortality and morbidity. Conclusion Thoraflex™ Hybrid remains a central player in the aortic arch prosthesis market. Its use it widespread and is associated with favourable design features and clinical outcomes relative to market alternatives.
Collapse
Affiliation(s)
- Sven Z C P Tan
- Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London, United Kingdom
| | - Matti Jubouri
- Hull York Medical School, University of York, York, United Kingdom
| | - Idhrees Mohammed
- Cardiovascular Department, SRM Institute of Medical Science, Institute of Cardiac & Aortic Disorders, SIMS Hospital, Chennai, India
| | - Mohamad Bashir
- Cardiovascular Department, SRM Institute of Medical Science, Institute of Cardiac & Aortic Disorders, SIMS Hospital, Chennai, India.,Vascular and Endovascular Surgery, Velindre University NHS Trust, Health Education and Improvement Wales, Cardiff, United Kingdom
| |
Collapse
|
10
|
Jubouri M, Abdelhaliem A. BioGlue and E-Vita Open NEO graft oozing: Long-term solution or band aid? J Card Surg 2021; 37:561-562. [PMID: 34914136 DOI: 10.1111/jocs.16181] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Accepted: 12/06/2021] [Indexed: 01/22/2023]
Abstract
BACKGROUND The introduction of the single-step total arch replacement (TAR) with frozen elephant trunk (FET) has revolutionised the field of aortic surgery. TAR is indicated when the aortic arch is involved in aortic pathologies such as Type A aortic dissection and thoracic aortic aneurysms. Several FET devices are available commercially for global use, and example is the E-Vita Open NEO hybrid prosthesis (HP) developed by CryoLife-JOTEC. Unlike other FET devices available, this HP in particular features a design that puts it at a disadvantage as it does not incorporate gelatine or collagen in its structure, which makes it permeable to blood. Several studies have reported incidence of post-anastomotic blood oozing through the E-Vita Open NEO right after weaning from cardiopulmonary bypass. AIMS This commentary aims to discuss the recent study by Tan et al. which investigated E-Vita NEO device oozing as well as the implications of using BioGlue to overcome this serious complications. METHODS We carried out a literature search on multiple electronic databases including PUBMED and Scopus in order to collate research evidence on E-Vita NEO device oozing, BioGlue health risks, and other commercially available and globally used FET devices such as Thoraflex Hybrid. RESULTS It is proven fact that the E-Vita NEO excessively oozes blood, and while BioGlue is a safe and effective agent when used in small amounts, the amount needed to coat the E-Vita Open NEO and achieve haemostasis exceeds this by a wide margin which poses patients to great potential health risks. The Thoraflex Hybrid Prosthesis developed by Terumo Aortic is a commercially available and globally used FET device with long-standing favourable outcomes. DISCUSSION Tan et al. recently conducted an interesting study which proved that the E-Vita NEO HP does excessively ooze blood and tackled the issue of pre-emptive BioGlue use to tackle this complication as suggested by Ho et al. This leads on to the main question, is the use of BioGlue with E-Vita Open NEO to overcome oozing a long-term sustainable solution or is it merely a band aid? CONCLUSION In the face of fierce commercial competition, the choice of design and material of the E-Vita Open NEO HP would benefit from reconsideration.
Collapse
Affiliation(s)
- Matti Jubouri
- Hull York Medical School, University of York, York, UK
| | - Amr Abdelhaliem
- Department of Vascular and Endovascular Surgery, Royal Blackburn Teaching Hospital, Blackburn, UK
| |
Collapse
|
11
|
Tan SZCP, Bashir M. Prevention versus cure: Is BioGlue priming the optimal strategy against E-Vita NEO graft oozing? J Card Surg 2021; 37:555-560. [PMID: 34907587 DOI: 10.1111/jocs.16179] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 10/25/2021] [Indexed: 01/05/2023]
Abstract
BACKGROUND Since the introduction of the E-Vita Open NEO aortic prosthesis in 2020, several incidences of post-anastomotic oozing from the polyester portion of the graft have emerged. The use of BioGlue to prime E-Vita Open NEO to prevent this has been suggested as a way to mitigate this worrying complication. We investigate the extent of graft oozing in E-Vita Open NEO and evaluate the use of BioGlue in preventing oozing, both experimentally and in terms of potential clinical complications. MATERIALS AND METHODS E-Vita Open NEO (in straight and branched configurations) was implanted in a perfused model. The distal stent graft and side branches were clamped, and the graft was pressurized with blood to 120 mmHg. The volume of blood (ml) oozing from the graft within 60 s was measured. Nonpressurized grafts were coated with BioGlue up to a thickness of 1, 2, and 3 mm, and the volume (mm3 ) of BioGlue required to do so was recorded. RESULTS Within 60 s, 250.0 ml of blood oozed from the grafts tested. 43.694, 87.389, and 174.778 mm3 of BioGlue were required to coat the device with 1, 2, and 3 mm of BioGlue. CONCLUSION Graft oozing from E-Vita Open NEO represents an omnipresent and worrying risk. The use of BioGlue herein is likely associated with several adverse consequences, which are an additional risk on top of that posed by graft oozing. These risks call into question the suitability of E-Vita Open NEO, especially when compared to alternative devices not affected by oozing.
Collapse
Affiliation(s)
- Sven Z C P Tan
- Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London, UK
| | - Mohamad Bashir
- Vascular and Endovascular Surgery, Velindre University NHS Trust, Health & Education Improvement, Wales, UK
| |
Collapse
|