Fumanelli J, Garibaldi S, Castaldi B, Di Candia A, Pizzuto A, Sirico D, Cuman M, Mirizzi G, Marchese P, Cantinotti M, Piacenti M, Assanta N, Viacava C, Di Salvo G, Santoro G. Mid-Term Electrical Remodeling after Percutaneous Atrial Septal Defect Closure with GCO Device in a Pediatric Population. J Clin Med 2023; 12:6334. [PMID: 37834978 PMCID: PMC10573535 DOI: 10.3390/jcm12196334] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Revised: 09/17/2023] [Accepted: 09/21/2023] [Indexed: 10/15/2023] Open
Abstract
BACKGROUND AND AIM The GORE® CARDIOFORM (GCO) septal occluder is an atrial septal defect/patent foramen ovale closure device with theoretical advantages over other commercialized devices thanks to its softness and anatomical compliance. Our aim was to evaluate the short- and medium-term electrocardiographic changes after percutaneous ASD closure with GCO in a pediatric population. METHODS We enrolled 39 patients with isolated ASD submitted to trans-catheter closure from January 2020 to June 2021. ECG was performed before, at 24 h and 6 months after the procedure. P wave dispersion, QTc and QTc dispersion were calculated. ECG Holter was recorded at 6 months after implantation. RESULTS Patients' age and body surface area (BSA) were 8.2 ± 4.2 years and 1.0 ± 0.3 m2 respectively. At the baseline, mean P wave dispersion was 40 ± 15 msec and decreased at 24 h (p < 0.002), without any further change at 6 months. At 24 h, PR conduction and QTc dispersion significantly improved (p = 0.018 and p < 0.02 respectively), while the absolute QTc value considerably improved after 6 months. During mid-term follow-up, QTc dispersion remained stable without a significant change in PR conduction. The baseline cardiac frequency was 88.6 ± 12.6 bpm, followed by a slight reduction at 24 h, with a further amelioration at 6 months after the procedure (87.3 ± 14.2, p = 0.9 and 81.0 ± 12.7, p = 0.009, respectively). After device deployment, two patients developed transient, self-limited junctional rhythm. One of them needed a short course of Flecainide for atrial ectopic tachycardia. No tachy/brady-arrhythmias were recorded at the 6-month follow-up. ASD closure resulted in a marked decrease in right heart volumes and diameters at 6 months after percutaneous closure. CONCLUSIONS Percutaneous ASD closure with the GCO device results in significant, sudden improvement of intra-atrial, atrio-ventricular and intraventricular electrical homogeneity. This benefit persists unaltered over a medium-term follow-up. These electrical changes are associated with a documented positive right heart volumetric remodeling at mid-term follow-up.
Collapse
Affiliation(s)
- Jennifer Fumanelli
- Pediatric Cardiology Unit, Woman's and Child's Health Department, Padua University, 35122 Padova, Italy
| | - Silvia Garibaldi
- Fondazione Toscana Gabriele Monasterio per la Ricerca Medica e di Sanità Pubblica, Electrophysiology Division, 56124 Pisa, Italy
- Fondazione Toscana Gabriele Monasterio per la Ricerca Medica e di Sanità Pubblica, Pediatric Cardiology and GUCH Unit, Heart Hospital "G. Pasquinucci", 54100 Massa, Italy
| | - Biagio Castaldi
- Pediatric Cardiology Unit, Woman's and Child's Health Department, Padua University, 35122 Padova, Italy
| | - Angela Di Candia
- Pediatric Cardiology Unit, Woman's and Child's Health Department, Padua University, 35122 Padova, Italy
| | - Alessandra Pizzuto
- Fondazione Toscana Gabriele Monasterio per la Ricerca Medica e di Sanità Pubblica, Pediatric Cardiology and GUCH Unit, Heart Hospital "G. Pasquinucci", 54100 Massa, Italy
| | - Domenico Sirico
- Pediatric Cardiology Unit, Woman's and Child's Health Department, Padua University, 35122 Padova, Italy
| | - Magdalena Cuman
- Fondazione Toscana Gabriele Monasterio per la Ricerca Medica e di Sanità Pubblica, Pediatric Cardiology and GUCH Unit, Heart Hospital "G. Pasquinucci", 54100 Massa, Italy
| | - Gianluca Mirizzi
- Fondazione Toscana Gabriele Monasterio per la Ricerca Medica e di Sanità Pubblica, Electrophysiology Division, 56124 Pisa, Italy
| | - Pietro Marchese
- Fondazione G. Monasterio CNR-Regione Toscana, Pediatric Cardiology and Cardiac Surgery, 56124 Pisa, Italy
| | - Massimiliano Cantinotti
- Fondazione G. Monasterio CNR-Regione Toscana, Pediatric Cardiology and Cardiac Surgery, 56124 Pisa, Italy
| | - Marcello Piacenti
- Fondazione Toscana Gabriele Monasterio per la Ricerca Medica e di Sanità Pubblica, Electrophysiology Division, 56124 Pisa, Italy
| | - Nadia Assanta
- Fondazione G. Monasterio CNR-Regione Toscana, Pediatric Cardiology and Cardiac Surgery, 56124 Pisa, Italy
| | - Cecilia Viacava
- Fondazione G. Monasterio CNR-Regione Toscana, Pediatric Cardiology and Cardiac Surgery, 56124 Pisa, Italy
| | - Giovanni Di Salvo
- Pediatric Cardiology Unit, Woman's and Child's Health Department, Padua University, 35122 Padova, Italy
| | - Giuseppe Santoro
- Fondazione Toscana Gabriele Monasterio per la Ricerca Medica e di Sanità Pubblica, Pediatric Cardiology and GUCH Unit, Heart Hospital "G. Pasquinucci", 54100 Massa, Italy
| |
Collapse
|
2
|
Stapleton GE. Pushing the boundaries: Are we approaching the limits for transcatheter ASD closure? J Card Surg 2022; 37:3207-3208. [PMID: 35900285 DOI: 10.1111/jocs.16785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Accepted: 07/11/2022] [Indexed: 11/27/2022]
Affiliation(s)
- Gary E Stapleton
- The Lillie Frank Abercrombie Section of Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, Texas, USA
| |
Collapse
|