1
|
Iezzi G, Perrotti V, Felice P, Barausse C, Piattelli A, Del Fabbro M. Are <7‐mm long implants in native bone as effective as longer implants in augmented bone for the rehabilitation of posterior atrophic jaws? A systematic review and meta‐analysis. Clin Implant Dent Relat Res 2020; 22:552-566. [DOI: 10.1111/cid.12946] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Accepted: 08/12/2020] [Indexed: 08/30/2023]
Affiliation(s)
- Giovanna Iezzi
- Department of Medical, Oral and Biotechnological Sciences University of Chieti‐Pescara “Gabriele D'Annunzio” Chieti Italy
| | - Vittoria Perrotti
- Department of Medical, Oral and Biotechnological Sciences University of Chieti‐Pescara “Gabriele D'Annunzio” Chieti Italy
| | - Pietro Felice
- Oral Surgery, Department of Biomedical and Neuromotor Sciences University of Bologna Bologna Italy
| | - Carlo Barausse
- Oral Surgery, Department of Biomedical and Neuromotor Sciences University of Bologna Bologna Italy
| | - Adriano Piattelli
- Department of Medical, Oral and Biotechnological Sciences University of Chieti‐Pescara “Gabriele D'Annunzio” Chieti Italy
- Biomaterials Engineering Catholic University of San Antonio de Murcia (UCAM) Murcia Spain
- Fondazione Villaserena per la Ricerca Città Sant'Angelo Pescara Italy
| | - Massimo Del Fabbro
- Department of Biomedical, Surgical and Dental Sciences University of Milan Milan Italy
- Dental Clinic IRCCS Orthopedic Institute Galeazzi Milan Italy
| |
Collapse
|
2
|
Short vs. Standard Length Cone Morse Connection Implants: An In Vitro Pilot Study in Low Density Polyurethane Foam. Symmetry (Basel) 2019. [DOI: 10.3390/sym11111349] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
The aim of the investigation was to evaluate the insertion torque, pull-out torque and implant stability quotient (ISQ) of short implants (SI) and standard length implants (ST) inserted into linearly elastic and constitutive isotropic symmetry polyurethane foam blocks. Short dental titanium implants with a Cone Morse connection and a conical shape (test implants: Test Implant A—diameter 5.5 mm and length 6 mm) (Test Implant B—diameter 5.5 mm and length 5 mm) were used for the present in vitro investigation. ST implants (4 mm diameter and 10 mm length), with a Cone Morse connection and a conical shape, were used as Control Implant A and as Control Implants B. These two latter implants had a different macro design. A total of 20 implants (5 Test A, 5 Test B, 5 Control A and 5 Control B) were used for the present research. The results were similar when comparing the Test A and Test B implants. The test implants had very good stability in polyurethane 14.88–29.76 kgm3 density blocks. The insertion torque values were very high for both types of test implant (25–32 Ncm on 14.88 kgm blocks, and up to 45 Ncm in 29.76 kgm3 blocks). The pull-out test values were very similar to the insertion torque values. The ISQ values were significantly high with 75–80 in 14.88 kgm3 blocks, and 78–83 in 29.76 kgm3 blocks. No differences were found in the values of the Control A and Control B implants. In both these implants, the insertion torque was quite low in the 14.88 kgm3 blocks (16–28 Ncm). Better results were found in the 29.76 kgm3 blocks. The pull-out values for these control implants were slightly lower than the insertion torque values. High ISQ values were found in both control implants (57–80). When comparing SI and ST implants, the SI had a similar if not better performance in low quality polyurethane foam blocks (14.88–29.76 kgm), corresponding to D3 and D4 bone.
Collapse
|