1
|
Alkindi S, Hamdoon Z, Aziz AM. Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: An in vitro study. J Dent 2024; 146:105045. [PMID: 38714241 DOI: 10.1016/j.jdent.2024.105045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 04/15/2024] [Accepted: 05/02/2024] [Indexed: 05/09/2024] Open
Abstract
OBJECTIVES This in vitro study compared the accuracy of conventional versus digital impression techniques for angulated and straight implants using two different impression coping and scan body designs. METHODS Two implant systems were used: Straumann and Dentegris. Two implants were placed for each system, straight and angulated at 15 degrees mesiodistally. Conventional impressions were made using the splinted open-tray technique using narrow impression coping (NIC) and wide impression coping (WIC). The stone casts produced from the conventional impression were digitized with a lab scanner (3Shape D2000). Digital impressions were made using four intraoral scanners (IOS): 3Shape Trios 3, Medit i700, Cerec Omnicam, and Emerald Planmeca using short scanbodies (SSB) and long scanbodies (LSB). The scanning was repeated ten times to generate the Standard Tessellation Language (STL) files. The distance and angle deviations between impression copings and scanbodies were measured in reference to the master model. RESULTS The trueness and precision of SSB and WIC were significantly better than LSB and NIC (p<0.001). The range trueness of the platform deviation was better with SSB (37.1 to 51.9) than LSB (89.6 to 127.9 μm) and for WIC than NIC in conventional impressions (58.2 and 75.1 μm, respectively). The trueness of the angle deviation of digital scans with SSB (0.11 to 0.25 degrees) was significantly better than scans with LSB (0.31 to 0.57 degrees) and for WIC than NIC (0.21 and 0.52 degrees, respectively). The precision of the platform deviation of digital scans with SSB (12.4 to 34.5 μm) was higher than other scans and conventional impressions (42.9 to 71.4 μm). The precision of the angle deviation of Medit i700 and Trios 3 with SSB (0.17 and 0.20 degrees, respectively) was higher than other scans with SSB and conventional impressions (0.54 to 1.63 degrees). CONCLUSIONS Digital scans with SSB were more accurate than conventional splinted open-tray impressions. The type of impression coping and scanbody significantly affected the impression accuracy. CLINICAL SIGNIFICANCE The use of a short scanbody can increase the accuracy of digital impressions, and wide impression coping can increase the accuracy of conventional impressions, resulting in improved clinical outcomes.
Collapse
Affiliation(s)
| | - Zaid Hamdoon
- Department of Oral and Craniofacial Health Sciences, College of Dental Medicine, University of Sharjah, Sharjah, UAE
| | - Ahmed M Aziz
- Department of Restorative Dentistry, College of Dental Medicine, University of Sharjah, Sharjah, UAE.
| |
Collapse
|
2
|
Eldin BSG, Talaat IA, Nawar NHH, Mohamed AMA. Effect of different fabrication workflows on the passive fit of screw-retained bar splinting two interforaminal implants: a parallel blinded randomised clinical trial. BMC Oral Health 2024; 24:410. [PMID: 38566034 PMCID: PMC10985940 DOI: 10.1186/s12903-024-04157-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Accepted: 03/18/2024] [Indexed: 04/04/2024] Open
Abstract
BACKGROUND To clinically compare the effect of the conventional and the digital workflows on the passive fit of a screw retained bar splinting two inter-foraminal implants. METHODS The current study was designed to be a parallel triple blinded randomised clinical trial. Thirty six completely edentulous patients were selected and simply randomized into two groups; conventional group (CG) and digital group (DG). The participants, investigator and outcome assessor were blinded. In the group (CG), the bar was constructed following a conventional workflow in which an open top splinted impression and a lost wax casting technology were used. However, in group (DG), a digital workflow including a digital impression and a digital bar milling technology was adopted. Passive fit of each bar was then evaluated clinically by applying the screw resistance test using the "flag" technique in the passive and non passive situations. The screw resistance test parameter was also calculated. Unpaired t-test was used for intergroup comparison. P-value < 0.05 was the statistical significance level. The study protocol was reviewed by the Research Ethics Committee in the author's university (Rec IM051811). Registration of the clinical trial was made on clinical trials.gov ID NCT05770011. An informed consent was obtained from all participants. RESULTS Non statistically significant difference was denoted between both groups in all situations. In the passive situation, the mean ± standard deviation values were 1789.8° ± 20.7 and1786.1° ± 30.7 for the groups (CG) and (DG) respectively. In the non passive situation, they were 1572.8° ± 54.2 and 1609.2° ± 96.9. Regarding the screw resistance test parameter, they were 217° ± 55.3 and 176° ± 98.8. CONCLUSION Conventional and digital fabrication workflows had clinically comparable effect on the passive fit of screw retained bar attachments supported by two dental implants.
Collapse
Affiliation(s)
- Bassant Sherif Gamal Eldin
- Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, Egypt.
| | - Ingy Amin Talaat
- Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, Egypt
| | - Noha Helmy Hassan Nawar
- Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, Egypt
| | - Ahmed Mostafa Abdelfattah Mohamed
- Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, Egypt
| |
Collapse
|
3
|
Cai ZZ, Li X, Wu XY, Lai HC, Shi JY. Does intra-oral scan improve the impression accuracy of full-arch implant-supported prostheses: A systematic review and meta-analysis. Clin Implant Dent Relat Res 2024. [PMID: 38517307 DOI: 10.1111/cid.13321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 01/17/2024] [Accepted: 03/03/2024] [Indexed: 03/23/2024]
Abstract
OBJECTIVES The present study aimed to systematically review the studies comparing the accuracy of intraoral scan (IOS) and conventional implant impressions (CI) in completely edentulous patients. MATERIALS AND METHODS Electronic searches were performed in PubMed, Embase and Cochrane CENTRAL up to December 1, 2023. Clinical studies and in vitro studies reporting the accuracy of digital full arch impressions were included. The primary outcome is the 3-dimensional deviations between the study reference models. A risk of bias assessment was performed for clinical studies. A stratified meta-analysis and a single-armed meta-analysis were conducted. RESULTS A total of 49 studies were included, with 8 clinical studies and 41 in vitro studies. For comparison between IOS and conventional impressions, studies were categorized into two groups based on the different measurement methods employed: RMS and CMM. In studies using RMS, the result favored the IOS in the unparalleled situation with the mean difference of -99.29 μm (95% CI: [-141.38, -57.19], I2 = 81%), while the result was opposite with the mean difference of 13.62 μm (95% CI: [10.97, 16.28], I2 = 26%) when implants were paralleled. For different brands of IOS, the accuracy ranged from 76.11 μm (95% CI: [42.36, 109.86]) to 158.63 μm (95% CI: [-14.68, 331.93]). CONCLUSIONS Accuracy of intraoral scan is clinically acceptable in edentulous arches, especially for unparalleled implants. More clinical studies are needed to verify the present finding.
Collapse
Affiliation(s)
- Zheng-Zhen Cai
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Xin Li
- Department of Stomatology, Affiliated Hospital of Jiangnan University, Wuxi, China
| | - Xin-Yu Wu
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Hong-Chang Lai
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Jun-Yu Shi
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| |
Collapse
|
4
|
Wu HK, Chen G, Zhang Z, Lin X, Huang X, Deng F, Li Y. Effect of artificial landmarks of the prefabricated auxiliary devices located at different arch positions on the accuracy of complete-arch edentulous digital implant scanning: An in-vitro study. J Dent 2024; 140:104802. [PMID: 38072336 DOI: 10.1016/j.jdent.2023.104802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 11/23/2023] [Accepted: 12/07/2023] [Indexed: 12/31/2023] Open
Abstract
OBJECTIVES To examine the effect of artificial landmarks of prefabricated auxiliary devices (PAD) located at different arch positions on the accuracy of complete-arch edentulous digital implant scanning. METHODS A reference model containing four analogs and PAD were fabricated by a 3D printer (AccuFab-C1s, 3DShining). 10 digital scans were performed using an intraoral scanner (Aoralscan 3, 3DShining), sv 1.0.0.3115, with artificial landmarks located at different arch positions: group I, without any artificial landmarks; group II, with artificial landmarks at the anterior region; group III, with artificial landmarks at the posterior region. group IV: with artificial landmarks at both anterior and posterior regions. For group V: Conventional open-tray splinted impressions. The reference file and conventional stone casts were digitalized by using a dental laboratory scanner. The related files were imported into inspection software for trueness and precision assessment. Statistical analysis was performed with One-way ANOVA and Kruskal-Wallis test. The level of significance was set at α=0.05. RESULTS For the global accuracy assessment, significantly higher global trueness was seen in group II (p < 0.01), III (p < 0.001), IV (p < 0.001) and V (p < 0.001) than group I. Significantly higher global precision was seen in group III (p < 0.001), IV (p < 0.001) and V (p < 0.001) than group I. For the local accuracy assessment, the PAD primarily improved accuracy on the linear deviations. CONCLUSIONS Artificial landmarks of PAD at different arch positions significantly influenced the scanning accuracy. Applying the PAD in group IV could achieve comparable outcomes to conventional open-tray splinted impressions. Artificial landmarks on the posterior region may be more pivotal than those on the anterior region. CLINICAL SIGNIFICANCE Group IV could achieve comparable accuracy to conventional open-tray splinted impressions.
Collapse
Affiliation(s)
- Hio Kuan Wu
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China
| | - Guanhui Chen
- Department of Stomatology, the Seventh Affiliated Hospital, Sun Yat-sen University, shenzhen, Guangdong, 518107, China
| | - Zhengchuan Zhang
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China
| | - Xiaoxuan Lin
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China
| | - Xiaoqiong Huang
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China
| | - Feilong Deng
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China
| | - Yiming Li
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China.
| |
Collapse
|
5
|
Ashraf Y, Abo El Fadl A, Hamdy A, Ebeid K. Effect of different intraoral scanners and scanbody splinting on accuracy of scanning implant-supported full arch fixed prosthesis. J ESTHET RESTOR DENT 2023; 35:1257-1263. [PMID: 37310208 DOI: 10.1111/jerd.13070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 05/30/2023] [Accepted: 05/31/2023] [Indexed: 06/14/2023]
Abstract
OBJECTIVE This study evaluated the accuracy of different intraoral scanners (IOS) for scanning of implant-supported full arch fixed prosthesis with different implant angulations with and without scanbodies splinting. MATERIALS AND METHODS Two maxillary models were designed and fabricated to receive an all-on-four implant retained. The models were divided into two groups according to the angulation of the posterior implant (Group 1; 30 and Group 2; 45). Each group was then divided into three subgroups according to the type of IOS used: Subgroup C; Primescan, subgroup T; Trios4, and subgroup M; Medit i600. Then each subgroup was divided into two divisions according to scanning technique; division S: splinted and division N: nonsplinted. Ten scans were made by each scanner for every division. Trueness and precision were analyzed using Geomagic controlX analysis software. RESULTS Angulation had no significant effect on both the trueness (p = 0.854) and precision (p = 0.347). Splinting had a significant effect on trueness and precision (p < 0.001). Scanner type had a significant effect on trueness (p < 0.001) and precision (p < 0.001). There was no significant difference between trueness of Trios 4 (112.15 ± 12.85) and Primescan (106.75 ± 22.58). However, there was a significant difference when compared to trueness of Medit i600 (158.50 ± 27.65). For the precision results Cerec Primescan showed the highest precision (95.45 ± 33.21). There was a significant difference between the three scanners, precision of Trios4 (109.72 ± 19.24) and Medit i600 (121.21 ± 17.26). CONCLUSION Cerec Primescan has higher trueness and precision than Trios 4 and Medit i600 in full arch implants scanning. Splinting the scanbodies improve the accuracy of full arch implants scanning. CLINICAL SIGNIFICANCE Cerec Primescan and 3Shape Trios 4 can be used for scanning of All-on-four implant supported prosthesis when scanbodies are splinted using a modular chain device.
Collapse
Affiliation(s)
- Yasmine Ashraf
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Ahmad Abo El Fadl
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Amina Hamdy
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Kamal Ebeid
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| |
Collapse
|
6
|
Vag J, Stevens CD, Badahman MH, Ludlow M, Sharp M, Brenes C, Mennito A, Renne W. Trueness and precision of complete arch dentate digital models produced by intraoral and desktop scanners: An ex-vivo study. J Dent 2023; 139:104764. [PMID: 37898433 DOI: 10.1016/j.jdent.2023.104764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 09/21/2023] [Accepted: 10/25/2023] [Indexed: 10/30/2023] Open
Abstract
OBJECTIVES The study aimed to compare the trueness and precision of five intraoral scanners (Emerald S, iTero Element 5D, Medit i700, Primescan, and Trios 4) and two indirect digitization techniques for both teeth and soft tissues on fresh mandibular and maxillary cadaver jaws. METHODS The maxilla and mandible of a fully dentate cadaver were scanned by the ATOS industrial scanner to create a master model. Then, the specimens were scanned eight times by each intraoral scanner (IOS). In addition, 8 polyvinylsiloxane (PVS) impressions were made and digitized with a Medit T710 desktop scanner. Stone models were then poured and again scanned with the desktop scanner. All IOS, PVS, and stone models were compared to the master model to calculate the mean absolute surface deviation for mandibular teeth, maxillary teeth, and palate. RESULTS For mandibular teeth, the PVS trueness was only significantly better than the Medit i700 (p < 0.001) and Primescan (p < 0.05). In maxillary teeth, the PVS trueness was significantly better than all IOSs (p < 0.05-0.001); the stone trueness was significantly better than Emerald S (p < 0.01), Medit i700 (p < 0.001) and Primescan (p < 0.01). In the palate, PVS and stone trueness were significantly lower than the iTero Element 5D (p < 0.01) and Trios 4 (p < p < 0.01). Stone trueness was significantly lower than the Medit i700 (p < 0.05). The precision in the palate was significantly lower for PVS and stone than for Emerald S (p < 0.01, p < 0.05), iTero Element 5D (p < 0.01, p < 0.01), Primescan (p < 0.001, p < 0.001), and Trios 4 (p < 0.001, p < 0.01). Significant differences in trueness between the IOSs were observed only in the mandibular teeth. The Medit i700 performed worse than Emerald S (p < 0.01) and iTero Element 5D (p < 0.01). For mandibular teeth, the Medit i700 was significantly more precise than Primescan (p < 0.01) and the Emerald S (p < 0.05). The Trios 4 was significantly less precise than Emerald S (p < 0.05). The precision of Medit i700 was significantly worse than iTero Element 5D (p < 0.01) for maxillary teeth, as well as the Primescan (p < 0.01) and Trios 4 (p < 0.05) for the palate. CONCLUSIONS In general, indirectly digitized models from PVS impressions had higher trueness than IOS for maxillary teeth; precision between the two methods was similar. IOS was more accurate for palatal tissues. The differences in trueness and precision for mandibular teeth between the various techniques were negligible. CLINICAL SIGNIFICANCE All investigated IOSs and indirect digitization could be used for complete arch scanning in mandibular and maxillary dentate arches. However, direct optical digitization is preferable for the palate due to the low accuracy of physical impression techniques for soft tissues.
Collapse
Affiliation(s)
- Janos Vag
- Department of Restorative Dentistry and Endodontics, Semmelweis University, Szentkirályi Street 47, Budapest 1088, Hungary.
| | | | - Mohammed H Badahman
- Digital Dentistry Masters Program, Medical University of South Carolina, Charleston, SC, USA
| | - Mark Ludlow
- Section Head of Implant Dentistry, Digital Dentistry, And Removable Prosthodontics at the University of Utah School of Dentistry, UT, USA
| | - Madison Sharp
- Senior Dental Student, Medical University of South Carolina, Charleston, SC, USA
| | - Christian Brenes
- Director of Digital Dentistry Masters Program, Medical University of South Carolina, Charleston, SC, USA
| | | | - Walter Renne
- Modern Optimized Dentistry Institute, Charleston, SC, USA
| |
Collapse
|
7
|
Vitai V, Németh A, Sólyom E, Czumbel LM, Szabó B, Fazekas R, Gerber G, Hegyi P, Hermann P, Borbély J. Evaluation of the accuracy of intraoral scanners for complete-arch scanning: A systematic review and network meta-analysis. J Dent 2023; 137:104636. [PMID: 37516338 DOI: 10.1016/j.jdent.2023.104636] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 07/11/2023] [Accepted: 07/25/2023] [Indexed: 07/31/2023] Open
Abstract
OBJECTIVES This network meta-analysis (NMA) aimed to compare the complete-arch scanning accuracy of different intraoral scanners (IOSs) to that of reference standard tessellation language (STL) files. DATA Studies comparing the trueness and precision of IOS STL files with those of reference STL scans for different arch types (dentate, edentulous, completely edentulous with implants, and partially edentulous with implants) were included in this study. SOURCES An electronic search of five databases restricted to the English Language was conducted in October 2021. STUDY SELECTION A total of 3,815 studies were identified, of which 114 were eligible for inclusion. After study selection and data extraction, pair-wise comparison and NMA were performed to define the accuracy of scanning for four arch subgroups using four outcomes (trueness and precision expressed as mean absolute deviation and root mean square values). Cochrane guidelines and the QUADAS-2 tool were used to assess the risk of bias. GRADE was used for certainty assessment. RESULTS Fifty-three articles were included in this NMA. Altogether, 26 IOSs were compared directly and indirectly in 10 network systems. The accuracy of IOSs scans were not significantly different from the reference scans for dentate arches (three IOSs), edentulous arches (three IOSs), and completely edentulous arches with implants (one IOS). The accuracy of the IOSs was significantly different from the reference scans for partially edentulous arches with implants. Significant accuracy differences were found between the IOSs, regardless of clinical scenarios. CONCLUSIONS The accuracy of complete-arch scanning by IOSs differs based on clinical scenarios. CLINICAL SIGNIFICANCE Different IOSs should be used according to the complete arch type.
Collapse
Affiliation(s)
- Viktória Vitai
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Budapest, Hungary
| | - Anna Németh
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Budapest, Hungary
| | - Eleonóra Sólyom
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Periodontology, Semmelweis University, Budapest, Hungary
| | - László Márk Czumbel
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Periodontology, Semmelweis University, Budapest, Hungary
| | - Bence Szabó
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Réka Fazekas
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Restorative Dentistry and Endodontics, Semmelweis University, Budapest, Hungary
| | - Gábor Gerber
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Section of Oral Morphology, Department of Anatomy Histology and Embryology, Semmelweis University, Budapest, Hungary
| | - Péter Hegyi
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Division of Pancreatic Diseases, Heart and Vascular Center, Semmelweis University, Budapest, Hungary; Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
| | - Péter Hermann
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Budapest, Hungary
| | - Judit Borbély
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Budapest, Hungary.
| |
Collapse
|
8
|
Floriani F, Lopes GC, Cabrera A, Duarte W, Zoidis P, Oliveira D, Rocha MG. Linear Accuracy of Intraoral Scanners for Full-Arch Impressions of Implant-Supported Prostheses: A Systematic Review and Meta-Analysis. Eur J Dent 2023; 17:964-973. [PMID: 36716787 PMCID: PMC10756734 DOI: 10.1055/s-0042-1758798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
This article compares the accuracy of intraoral scanners (IOSs) used in the digital impression of full arches to fabricate implant-supported complete prostheses. This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and was registered in the Open Science Framework (DOI 10.17605/OSF.IO/CPM9K). Six electronic databases, gray literature databases, and a manual search were performed in April 2022. Studies that evaluated the accuracy of intraoral scan impressions compared with conventional impressions in full-arch impressions were included for complete implant-supported prostheses. In addition, an adapted checklist for reporting in vitro studies was used to assess the risk of bias. Meta-analysis was conducted using a random-effects Hunter- Schmidt model. Nine studies were included in the analysis. IOS impressions present higher accuracy (137.86 μm) than conventional impressions (182.51 μm) (p<0.001). The heterogeneity of the study's methodology was I2¼18.34. However, impression accuracy varies significantly with scan body type, IOS type, scanning strategy, and modification technique. For most IOS systems, the acceptable clinical threshold of linear accuracy of 200 μm can be achieved, except for the True Definition Scanner in one of the studies. Based on the results of the included studies, digital impressions using IOS present similar or better linear accuracy than conventional impression techniques.
Collapse
Affiliation(s)
- Franciele Floriani
- Department of Periodontology, University of Florida College of Dentistry, Gainesville, Florida, United States
- Universidade Federal de Santa Catarina, Florianópolis, SC, Brazil
| | | | - Alexandre Cabrera
- Division of Prosthodontics, Department of Restorative Dental Science, University of Florida, Gainesville, Florida, United States
| | - Wagner Duarte
- Department of Periodontology, University of Florida, Gainesville, Florida, United States
| | - Panagiotis Zoidis
- Division of Prosthodontics, Department of Restorative Dental Science, University of Florida, Gainesville, Florida, United States
| | - Dayane Oliveira
- Department of Restorative Dental Sciences, Center for Dental Biomaterials, College of Dentistry, Gainesville, Florida, United States
| | - Mateus Garcia Rocha
- Department of Restorative Dental Sciences, Center for Dental Biomaterials, College of Dentistry, Gainesville, Florida, United States
| |
Collapse
|
9
|
Espona J, Vidal-Ponsoda C, Quintana P, Henarejos-Domingo V, Roig M. A fully digital protocol to provide a fixed interim complete denture for immediate loading for a completely edentulous patient: A dental technique. J Prosthet Dent 2023; 130:171-178. [PMID: 34711405 DOI: 10.1016/j.prosdent.2021.09.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 09/20/2021] [Accepted: 09/21/2021] [Indexed: 11/29/2022]
Abstract
Complete arch immediate-loading implant-supported prostheses can represent a major challenge for the patient and the dental team. Obtaining stable references and an accurate occlusal record after implant placement to provide an interim prosthesis is a difficult task and can deviate from the initial treatment plan. The described technique presents a fully digital protocol to provide an immediate complete arch implant-supported fixed interim prosthesis for edentulous patients by making postoperative cone beam computed tomography and intraoral digital scans that correlate with the previous plan.
Collapse
Affiliation(s)
- José Espona
- Associate Professor, Department of Restorative Dentistry, School of Dentistry, International University of Catalunya, Barcelona, Spain
| | - Carla Vidal-Ponsoda
- Resident, Department of Restorative Dentistry, School of Dentistry, International University of Catalunya, Barcelona, Spain
| | - Pau Quintana
- Assistant Professor, Department of Restorative Dentistry, School of Dentistry, International University of Catalunya, Barcelona, Spain
| | - Víctor Henarejos-Domingo
- Private practice, Barcelona, Spain; Associate Professor, Department of Restorative Dentistry, School of Dentistry, International University of Catalunya, Barcelona, Spain.
| | - Miguel Roig
- Chairman and Professor, Department of Restorative Dentistry, School of Dentistry, International University of Catalunya, Barcelona, Spain
| |
Collapse
|
10
|
Akkal O, Korkmaz IH, Bayindir F. Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions. J Adv Prosthodont 2023; 15:179-188. [PMID: 37662853 PMCID: PMC10471506 DOI: 10.4047/jap.2023.15.4.179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 08/16/2023] [Accepted: 08/21/2023] [Indexed: 09/05/2023] Open
Abstract
PURPOSE This in vitro study aimed to evaluate the performance of digital intraoral scanners in a completely edentulous patient with angled and parallel implants. MATERIALS AND METHODS A total of 6 implants were placed at angulations of 0°, 5°, 0°, 0°, 15°, and 0° in regions #36, #34, #32, #42, #44, and #46, respectively, in a completely edentulous mandibular polyurethane model. Then, the study model created by connecting a scan body on the implants was scanned using a model scanner, and a 3D reference model was obtained. Three different intraoral scanners were used for digital impressions (PS group, TR group, and CS group, n = 10 in each group). The distances and angles between the scan bodies in these measurement groups were measured. RESULTS While the Primescan (PS) impression group had the highest accuracy with 38 µm, the values of 104 µm and 171 µm were obtained with Trios 4 IOSs (TR) and Carestream 3600 (CS), respectively (P = .001). The CS scanner constituted the impression group with the highest deviation in terms of accuracy. In terms of dimensional differences in the angle parameter, a statistically significant difference was revealed among the mean deviation angle values according to the scanners (P < .001). While the lowest angular deviation was obtained with the PS impression group with 0.185°, the values of 0.499° and 1.250° were obtained with TR and CS, respectively. No statistically significant difference was detected among the impression groups in terms of precision values (P > .05). CONCLUSION A statistically significant difference was found among the three digital impression groups upon comparing the impression accuracy. Implant angulation affected the impression accuracy of the digital impression groups. The most accurate impressions in terms of both distance and angle deviation were obtained with the PS impression group.
Collapse
Affiliation(s)
- Ozcan Akkal
- Department of Prosthodontics, Atatürk University Faculty of Dentistry, Erzurum, Turkiye
| | - Ismail Hakki Korkmaz
- Department of Mechanical Engineering, Faculty of Engineering and Architecture, Erzurum Technical University, Erzurum, Turkiye
| | - Funda Bayindir
- Department of Prosthodontics, Atatürk University Faculty of Dentistry, Erzurum, Turkiye
| |
Collapse
|
11
|
Kernen F, Brändle D, Wagendorf O, Recca M, Mehrhof J, Vach K, Nahles S, Nelson K, Flügge T. Enhancing intraoral scanner accuracy using scan aid for multiple implants in the edentulous arch: An in vivo study. Clin Oral Implants Res 2023; 34:793-801. [PMID: 37314046 DOI: 10.1111/clr.14107] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 05/10/2023] [Accepted: 05/27/2023] [Indexed: 06/15/2023]
Abstract
OBJECTIVES Intraoral scans of multiple implants in the edentulous arch are challenged by the absence of a distinct surface morphology between scan bodies. A scan aid was applied in such situation and evaluated for intraoral scanning accuracy in vivo. MATERIALS AND METHODS 87 implants in 22 patients were scanned with scan aid (SA) and without scan aid (NO) using two different intraoral scanners (CS3600 [CS] and TRIOS3 [TR]). Master casts were digitized by a laboratory scanner. Virtual models were superimposed using an inspection software and Linear deviation and precision were measured. Statistical analysis was performed using linear mixed models (α = .05). RESULTS Total mean linear deviation within the CS group was 189 μm without scan aid and 135 μm when using the scan aid. The TR group's total mean deviation was 165 μm with and without a scan aid. Significant improvement with scan aid was observed for the CS group (p = .001), and no difference was found in the TR group. 96% of scan bodies were successfully scanned in the TR-SA group compared to 86% for the TR-NO group, 83% for the CS-SA, and 70% for the CS-NO group, respectively. CONCLUSIONS The evaluated scan aid improved linear deviation compared to unsplinted scans for the CS group but not for the TR group. These differences could originate from different scanning technologies used, active triangulation (CS) and confocal microscopy (TR). The scan aid improved the ability to recognize scan bodies successfully with both systems, which could have a favorable clinical impact overall.
Collapse
Affiliation(s)
- Florian Kernen
- Department of Oral and Maxillofacial Surgery, Translational Implantology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Dominik Brändle
- Department of Oral and Maxillofacial Surgery, Translational Implantology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Oliver Wagendorf
- Department of Oral and Maxillofacial Surgery, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Mario Recca
- Department of Prosthetic Dentistry, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | | | - Kirstin Vach
- Institute of Medical Biometry and Statistics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Susanne Nahles
- Department of Prosthetic Dentistry, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Katja Nelson
- Department of Oral and Maxillofacial Surgery, Translational Implantology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Tabea Flügge
- Department of Prosthetic Dentistry, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
12
|
Todaro C, Cerri M, Rodriguez Y Baena R, Lupi SM. Full-Arch Guided Restoration and Bone Regeneration: A Complete Digital Workflow Case Report. Healthcare (Basel) 2023; 11:healthcare11091301. [PMID: 37174843 PMCID: PMC10177883 DOI: 10.3390/healthcare11091301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 04/19/2023] [Accepted: 04/23/2023] [Indexed: 05/15/2023] Open
Abstract
OBJECTIVE complex rehabilitations present multiple difficulties, regarding both the planification of the surgery and the design of the prothesis. A digital approach can support the workflow, as well as the degree of intraoperative precision, and improve the long-term prognosis. METHODS A surgical guide was designed for implant placement. An extensive regeneration of the upper jaw was performed with contextual implant insertion, and a delayed load rehabilitation was chosen. After four months, a second surgery and a simultaneous soft tissue augmentation was performed, and a 3D-printed temporary restoration was placed. After another two months, new dental and facial scans, smile design, and facial bite registrations were obtained. Upper and lower dentures were built using an exclusively digital workflow. Both metal substructures were passivated and cemented in one session; in the following appointment, the aesthetic and occlusal checks were carried out. During the third visit, both prostheses were delivered. RESULTS Careful case planning and the surgical guide made it possible to achieve primary stability and acceptable emergence profiles in an extremely reabsorbed upper jaw. Leukocyte-Platelet Rich Fibrin (L-PRF) made the extensive bone regeneration more approachable and lowered the post-operative pain and swelling, while speeding up the soft tissue healing process. During the re-entry surgery, the volumes of soft tissues were increased to improve aesthetics, and the amount of keratinized gingiva around the six implants was also increased. Smile design and facial scans have provided the means to create acceptable aesthetics and function in a few sessions with minimal patient discomfort. CONCLUSIONS Computer-assisted implantology is a safe and precise method of performing dental implant surgery. Preliminary studies have a high degree of accuracy, but further studies are needed to arrive at a fully digital clinical protocol at all stages.
Collapse
Affiliation(s)
- Claudia Todaro
- School of Dentistry, Department of Clinical Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy
| | | | - Ruggero Rodriguez Y Baena
- School of Dentistry, Department of Clinical Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy
| | - Saturnino Marco Lupi
- School of Dentistry, Department of Clinical Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy
| |
Collapse
|
13
|
Dohiem MM, Abdelaziz MS, Abdalla MF, Fawzy AM. Digital assessment of the accuracy of implant impression techniques in free end saddle partially edentulous patients. A controlled clinical trial. BMC Oral Health 2022; 22:486. [PMID: 36371189 DOI: 10.1186/s12903-022-02505-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Accepted: 10/11/2022] [Indexed: 11/15/2022] Open
Abstract
Abstract
Objectives
This in vivo study aims to assess the accuracy of the digital intraoral implant impression technique, the conventional closed-tray impression technique, and open-tray impression techniques in a standardized method of data segmentation along with the best-fit algorithm to overcome the inconsistency of results of previous studies regarding implant impression techniques.
Materials and methods
Sixteen implants were placed in eight patients. Each patient has undergone four impression techniques: direct intraoral scanning of the stock abutment, intraoral scanning using a scan body, conventional closed tray impression technique, and the conventional open tray impression technique. The conventional impressions were poured into stone casts with analogues and stock abutments and scanned using a desktop scanner. In intraoral scanning of the scan body, computer-aided design software was used for the replacement of the scan body with a custom-made abutment that is identical to the stock abutment, allowing comparison with the other impression techniques. The deviation in implant position between the groups was measured using special 3D inspection and metrology software. Statistical comparisons were carried out between the studied groups using a one-way analysis of variance (ANOVA) test.
Results
The total deviation between groups was compared to the reference group represented by the intraoral scanning of the abutment. The total deviation was statistically significantly different (P = 0.000) among the different studied groups. The mean deviation was recorded as 21.45 ± 3.3 μm, 40.04 ± 4.1 μm, and 47.79 ± 4.6 μm for the intraoral scanning of the scan body, the conventional closed, and open tray, respectively.
Conclusion
For implant impressions in partially edentulous patients, intraoral oral scanning using a scan body significantly improves scanning and overall accuracy. Regarding conventional impressions, the closed-tray impression techniques showed more accuracy than conventional open-tray impressions.
Clinical relevance
Intraoral digital implant impression using scan body offers more accuracy than conventional implant impression techniques for recording posterior implant position in free-end saddle partially edentulous patients.
Collapse
|
14
|
Kosago P, Ungurawasaporn C, Kukiattrakoon B. Comparison of the accuracy between conventional and various digital implant impressions for an implant-supported mandibular complete arch fixed prosthesis: an in vitro study. J Prosthodont 2022. [PMID: 36083233 DOI: 10.1111/jopr.13604] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Accepted: 08/27/2022] [Indexed: 11/28/2022] Open
Abstract
PURPOSE This in vitro study compared the accuracy between conventional and different intraoral scanner impression methods and stereophotogrammetry term of 3D deviation for a complete mandibular edentulous arch with 5 placed implants. MATERIALS AND METHODS An edentulous mandibular model was prepared with three straight and two 17° angled screw-retained abutments screwed on implants. Different impression techniques were compared: 1 conventional impression, CO (Open-tray splint impression coping, Polyether), 3 groups of intraoral scanners, TS (Trios 4), IT (iTero Element 2), and PS (Primescan), and 1 Stereophotogrammetry, PIC (Precise Implants Capture). An extraoral scanner (E4 scanner) was used to digitize the reference model as a control group. Scan body positions were compared with 3D deviation by using a 3D analysis software program (Geomagic ControlX 2020.1.1) with the best fit alignment technique. The accuracy of the scan bodies' position of each impression technique between each group area was analyzed using one-way ANOVA followed by Scheffé's comparison test for trueness and precision. (α = 0.05) RESULTS: Statistical 3D deviations of the whole scan body were found among the CO, TS, PS, IT, and PIC groups for both trueness (p < 0.05) and precision (p < 0.05). PIC showed the least 3D deviation of trueness (48.74 ± 1.80 μm) and precision (5.46 ± 1.10 μm), followed by TS, PS, IT, and CO. CO had the highest 3D deviation of trueness (141 ± 5.58 μm) and precision (40.4 ± 1.3.39 μm), which was significantly different from PIC, TS, and PS. CONCLUSION For completed-arch digital implant impressions, a stereophotogrammetry has shown better accuracy than other digital and conventional impression techniques, especially in terms of precision. The highest 3D deviation was found in the conventional splint open tray impression technique. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Pitchaporn Kosago
- Department of Conservative Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| | - Chatcharwin Ungurawasaporn
- Department of Conservative Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| | - Boonlert Kukiattrakoon
- Department of Conservative Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| |
Collapse
|
15
|
Hou X, Xu X, Zhao M, Kong J, Wang M, Lee ES, Jia Q, Jiang HB. An overview of three-dimensional imaging devices in dentistry. J ESTHET RESTOR DENT 2022; 34:1179-1196. [PMID: 35968802 DOI: 10.1111/jerd.12955] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 07/27/2022] [Accepted: 07/28/2022] [Indexed: 12/27/2022]
Abstract
OBJECTIVE To review four types of three-dimensional imaging devices: intraoral scanners, extraoral scanners, cone-beam computed tomography (CBCT), and facial scanners, in terms of their development, technologies, advantages, disadvantages, accuracy, influencing factors, and applications in dentistry. METHODS PubMed (National Library of Medicine) and Google Scholar databases were searched. Additionally, the scanner manufacturers' websites were accessed to obtain relevant data. Four authors independently selected the articles, books, and websites. To exclude duplicates and scrutinize the data, they were uploaded to Mendeley Data. In total, 135 articles, two books, and 17 websites were included. RESULTS Research and clinical practice have shown that oral and facial scanners and CBCT can be used widely in various areas of dentistry with high accuracy. CONCLUSION Although further advancement of these devices is desirable, there is no doubt that digital technology represents the future of dentistry. Furthermore, the combined use of different devices may bring dentistry into a new era. These four devices will play a significant role in clinical utility with high accuracy. The combined use of these devices should be explored further. CLINICAL SIGNIFICANCE The four devices will play a significant role in clinical use with high accuracy. The combined use of these devices should be explored further.
Collapse
Affiliation(s)
- Xingyu Hou
- The Conversationalist Club, School of Stomatology, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China
| | - Xiaotong Xu
- The Conversationalist Club, School of Stomatology, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China
| | - Menghua Zhao
- The Conversationalist Club, School of Stomatology, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China
| | - Jiawen Kong
- The Conversationalist Club, School of Stomatology, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China
| | - Mingchang Wang
- The Conversationalist Club, School of Stomatology, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China
| | - Eui-Seok Lee
- Department of Oral and Maxillofacial Surgery, Graduate School of Clinical Dentistry, Korea University, Seoul, Republic of Korea
| | - Qi Jia
- The Conversationalist Club, School of Stomatology, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China
| | - Heng Bo Jiang
- The Conversationalist Club, School of Stomatology, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China
| |
Collapse
|
16
|
Kernen FR, Recca M, Vach K, Nahles S, Nelson K, Flügge TV. In vitro scanning accuracy using different aids for multiple implants in the edentulous arch. Clin Oral Implants Res 2022; 33:1010-1020. [PMID: 35861128 DOI: 10.1111/clr.13982] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 06/13/2022] [Accepted: 06/24/2022] [Indexed: 11/27/2022]
Abstract
OBJECTIVES Optical impressions of implants in the edentulous arch are challenged by the absence of distinct surface morphology between multiple implant scan bodies. The purpose of this in vitro study was to evaluate a newly developed scan aid in various designs and colors to improve the accuracy of multi-implant scans. MATERIAL AND METHODS A universal scan aid in three different designs (circular, square, irregular) and three different materials (colors: beige, gray, white) was applied to the implant scan bodies of a master model of 6 implants in an edentulous maxilla. Ten scans using an intra-oral scanner of each scan aid were acquired. Reference scanning was performed using a desktop optical scanner. Alignment of scans was performed at the first scan body in a three-dimensional modeling and inspection software and deviations for trueness and precision were calculated using the signed nearest neighbor method and then statistically analyzed (α=.05). RESULTS Overall, the beige irregular scan aid had the highest trueness and showed significant differences compared to unsplinted scans. The precision showed more heterogenous results and decreased when using the scan aid. Ease of use was observed with the irregular gray scan aid due to its increased elongation at break. CONCLUSIONS The evaluated scan aid led to improved trueness when compared to unsplinted scans. Even though the irregular design in beige color showed highest trueness, the poor fracture strength of the tested material requires further improvement.
Collapse
Affiliation(s)
- Florian Robert Kernen
- Department of Oral and Maxillofacial Surgery, Translational Implantology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Mario Recca
- Department of Oral and Maxillofacial Surgery, Translational Implantology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Kirstin Vach
- Institute of Medical Biometry and Statistics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Susanne Nahles
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
| | - Katja Nelson
- Department of Oral and Maxillofacial Surgery, Translational Implantology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Tabea Viktoria Flügge
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
| |
Collapse
|
17
|
Reliability and Time Efficiency of Digital vs. Analog Bite Registration Technique for the Manufacture of Full-Arch Fixed Implant Prostheses. J Clin Med 2022; 11:jcm11102882. [PMID: 35629010 PMCID: PMC9145758 DOI: 10.3390/jcm11102882] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 04/29/2022] [Accepted: 05/12/2022] [Indexed: 01/25/2023] Open
Abstract
Objective: Information about full-digital protocols for bite registration with intraoral scanners on multiple implants in the edentulous jaw is scarce. The purpose of this comparative in vivo study was to investigate the reliability and time efficiency of a novel full-digital bite registration technique for the manufacture of full-arch maxillary fixed implant prostheses. Material and methods: In ten patients, a full-arch maxillary fixed implant prosthesis was manufactured on multi-unit abutment level through an analog prosthetic workflow. The bite registration was performed with use of a screw-retained polymethyl methacrylate (PMMA) verification jig with detachable wax rim. To articulate the definitive edentulous maxillary implant cast in centric relation at the appropriate occlusal vertical dimension (OVD) to the mandibular antagonist cast, a type II articulator (Artex, Amann Girrbach) was used. Three to six months later, a full-digital bite registration was performed with use of dual-function scan bodies and bilateral connected bite pillars. The bite pillars screwed into the scan bodies were used to adjust and articulate the edentulous maxillary implant arch to the mandibular antagonist arch at the defined OVD. Treatment time for analog and digital bite registration technique was measured in each patient. The reliability of the digital bite registration technique was evaluated by 3D comparison of two sets of stereo lithographic (STL) files obtained from each patient. The three-dimensional deviation was defined along the X-, Y- and Z-axes (Geomagic Control X, 3D Systems Inc., Rock Hill, SC, USA). Results: The treatment time for digital bite registration using dual-function scan bodies and bite pillars was significantly shorter than analog bite registration with verification jig and wax rim (60.30%, SD 5.72%). Minor differences between the two techniques were observed with a linear deviation range of 1115 µm (SD 668 µm) overall, 46.2 µm (SD 731.3 µm) along the X-axis, −200.3 µm (SD 744.3 µm) along the Y-axis and 67.1 µm (SD 752.2 µm) along the Z-axis. Bilateral balanced contacts were registered in all patients during full-digital bite registration. Conclusions: The novel digital bite registration technique with dual-function scan bodies and bite pillars allows for a full-digital workflow for full-arch implant supported restorations. The digital bite workflow was 60% faster, and the overall deviation was around 1 mm, which can be considered clinically acceptable.
Collapse
|
18
|
Orejas-Perez J, Gimenez-Gonzalez B, Ortiz-Collado I, Thuissard IJ, Santamaria-Laorden A. In Vivo Complete-Arch Implant Digital Impressions: Comparison of the Precision of Three Optical Impression Systems. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19074300. [PMID: 35409985 PMCID: PMC8998197 DOI: 10.3390/ijerph19074300] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 03/26/2022] [Accepted: 03/31/2022] [Indexed: 02/04/2023]
Abstract
(1) Multiple in vitro studies reported insufficient accuracy of intraoral scanners (IOSs) for complete-arch multiple implant impression. The aim of the study is to analyze the precision of three IOSs, PIC dental (Pic dental, Iditec North West SL), TRIOS 3 (3Shape), and True Definition (Midmark Corporation) and the influence of several factors in the edentulous complete maxillary and mandibular arch. (2) A fully edentulous patient with eight implants in the maxillary and in the mandibular jaw was selected. Five impressions were taken per system and arch. A suprastructure was designed on each digital working cast. The precision was analyzed comparing each of the 28 distances and seven relative angulations of the abutments of all the designed suprastructures. The descriptive statistics, the Student's t-test, and the ANOVA test were used to analyze the data (α = 0.05). (3) Significant differences were observed when comparing the IOSs in some of the distances and angulations. (4) The increase in the distance between implants affected the precision of T and TD but not the PIC system. The type of arch did not affect the PIC precision, but the T and TD systems performed worse in the mandibular arch. The system with the best precision was the PIC, followed by TD, and then T.
Collapse
Affiliation(s)
- Jaime Orejas-Perez
- Faculty of Biomedical and Health Sciences, Department of Clinical Dentistry, Universidad Europea de Madrid, 28670 Madrid, Spain; (J.O.-P.); (I.O.-C.)
| | - Beatriz Gimenez-Gonzalez
- Department of Implantology and Prosthetic Dentistry, Academic Center for Dentistry Amsterdam ACTA, 1081 LA Amsterdam, The Netherlands;
| | - Ignacio Ortiz-Collado
- Faculty of Biomedical and Health Sciences, Department of Clinical Dentistry, Universidad Europea de Madrid, 28670 Madrid, Spain; (J.O.-P.); (I.O.-C.)
| | - Israel J. Thuissard
- Faculty of Biomedical and Health Sciences, Department of Medicine, Universidad Europea de Madrid, 28670 Madrid, Spain;
| | - Andrea Santamaria-Laorden
- Faculty of Biomedical and Health Sciences, Department of Clinical Dentistry, Universidad Europea de Madrid, 28670 Madrid, Spain; (J.O.-P.); (I.O.-C.)
- Correspondence:
| |
Collapse
|
19
|
Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19042026. [PMID: 35206217 PMCID: PMC8872312 DOI: 10.3390/ijerph19042026] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 02/04/2022] [Accepted: 02/07/2022] [Indexed: 12/20/2022]
Abstract
The aim of this systematic review was to evaluate the in vitro accuracy of dental implants impressions taken with intraoral scanner compared with impressions taken with conventional techniques. Two independent reviewers conducted a systematic electronic search in the PubMed, Web of Science and Scopus databases. Some of the employed key terms, combined with the help of Boolean operators, were: "dental implants", "impression accuracy", "digital impression" and "conventional impression". Publication dates ranged from the earliest article available until 31 July 2021. A total of 26 articles fulfilled the inclusion criteria: 14 studies simulated complete edentation (CE), nine partial edentation (PE) and only two simulated a single implant (SI); One study simulated both CE and SI. In cases of PE and SI, most of the studies analyzed found greater accuracy with conventional impression (CI), although digital impression (DI) was also considered adequate. For CE the findings were inconclusive as six studies found greater accuracy with DI, five found better accuracy with CI and four found no differences. According to the results of this systematic review, DI is a valid alternative to CI for implants in PE and SI, although CI appear to be more accurate. For CE the findings were inconclusive, so more studies are needed before DI can be recommended for all implant-supported restorations.
Collapse
|
20
|
Pozzi A, Arcuri L, Lio F, Papa A, Nardi A, Londono J. Accuracy of complete-arch digital implant impression with or without scanbody splinting: an in vitro study. J Dent 2022; 119:104072. [DOI: 10.1016/j.jdent.2022.104072] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 02/01/2022] [Accepted: 02/17/2022] [Indexed: 10/19/2022] Open
|
21
|
Marinis A, Papaspyridakos P, Sicilia E, Bernandes SR, Touloumi F, Chochlidakis K, Weber HP. Digital Workflow for Double Complete Arch Zirconia Prostheses Utilizing a Novel Scan Body. J Prosthodont 2021; 31:4-8. [PMID: 34453373 DOI: 10.1111/jopr.13417] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/23/2021] [Indexed: 12/01/2022] Open
Abstract
The purpose of this clinical report is to present a complete digital workflow for the fabrication of complete arch fixed zirconia implant restorations. An intraoral scanner was used to capture the implants' position at the abutment level and also the patient's existing interim prostheses with the double digital scanning technique. A novel scan body and impression pin were utilized throughout the scanning process which allowed for the accurate and reproducible superimposition of the generated Standard Tesselation Language (STL) files. Prosthesis prototypes were digitally designed and fabricated, tried in, and verified intraorally. The definitive zirconia prostheses were then fabricated and delivered to the patient. This technique can be utilized in both arches overcoming the absence of stable intraoral landmarks for superimposition of STL files.
Collapse
Affiliation(s)
| | - Panos Papaspyridakos
- Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, MA.,Department of Prosthodontics, University of Rochester Eastman Institute for Oral Health, Rochester, NY
| | - Elena Sicilia
- Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, MA
| | - Sergio Rocha Bernandes
- The Latin American Institute of Dental Research and Education, Head of New Product Development and Clinical Practice at Neodent, Curitiba, Brazil
| | - Foteini Touloumi
- Division of Prosthodontics, University of Connecticut Health Center, Farmington, CT
| | - Konstantinos Chochlidakis
- Department of Prosthodontics, University of Rochester Eastman Institute for Oral Health, Rochester, NY
| | - Hans-Peter Weber
- Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, MA.,Clear Choice Dental Implant Center, Quincy, MA
| |
Collapse
|
22
|
Zandinejad A, Liang H, Fisher Cosio NA, Revilla-León M. Fabrication of a complete-arch implant-supported fixed interim prosthesis by using a cone beam computed tomography digital scan for a patient with primordial dwarfism: A dental technique. J Prosthet Dent 2021; 128:1179-1183. [PMID: 33933270 DOI: 10.1016/j.prosdent.2021.03.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 03/18/2021] [Accepted: 03/18/2021] [Indexed: 11/30/2022]
Abstract
A complete-arch implant-supported interim prosthesis was fabricated from a cone beam computed tomography digital scan of the implant abutments for a patient with primordial dwarfism. The patient presented with limited mouth opening, which hindered the use of a conventional impression technique. The described technique provided an alternative digital procedure to obtain a virtual implant definitive cast.
Collapse
Affiliation(s)
- Amirali Zandinejad
- Associate Professor and Program Director AEGD Residency Program, Comprehensive Dentistry Department, College of Dentistry, Texas A&M University, Dallas, Texas
| | - Hui Liang
- Professor and Pre-Doctoral Program Director of Oral Radiology, Department of Diagnostic Sciences, College of Dentistry, Texas A&M University, Dallas, Texas
| | - Nicole A Fisher Cosio
- AEGD Resident, Comprehensive Dentistry Department, College of Dentistry, Texas A&M University, Dallas, Texas
| | - Marta Revilla-León
- Assistant Professor and Assistant Program Director AEGD Residency Program, Comprehensive Dentistry Department, College of Dentistry, Texas A&M University, Dallas, Texas; Affiliate Faculty Graduate Prosthodontics, Restorative Dentistry Department, School of Dentistry, University of Washington, Seattle, Wash; Researcher at Revilla Research Center, Madrid, Spain.
| |
Collapse
|