1
|
Chattoraj S, Daugherity P, McDermott T, Olsofsky A, Roth WJ, Tobyn M. Sticking and Picking in Pharmaceutical Tablet Compression: An IQ Consortium Review. J Pharm Sci 2018; 107:2267-2282. [DOI: 10.1016/j.xphs.2018.04.029] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Revised: 04/23/2018] [Accepted: 04/27/2018] [Indexed: 12/20/2022]
|
2
|
Maniruzzaman M, Ross SA, Islam MT, Scoutaris N, Nair A, Douroumis D. Increased dissolution rates of tranilast solid dispersions extruded with inorganic excipients. Drug Dev Ind Pharm 2017; 43:947-957. [DOI: 10.1080/03639045.2017.1287716] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Mohammed Maniruzzaman
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham Maritime, Chatham, Kent, UK
| | - Steven A. Ross
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham Maritime, Chatham, Kent, UK
| | - Muhammad Tariqul Islam
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham Maritime, Chatham, Kent, UK
| | - Nikolaos Scoutaris
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham Maritime, Chatham, Kent, UK
| | - Arun Nair
- Fuji Chemical Industry Co, Ltd, International Business Division, Minato-Ward, Tokyo, Japan
| | - Dennis Douroumis
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham Maritime, Chatham, Kent, UK
| |
Collapse
|
3
|
Maniruzzaman M, Farias S, Slipper IJ, Boateng JS, Chowdhry BZ, Nair A, Douroumis D. Development and optimization of ketoconazole oral strips by means of continuous hot-melt extrusion processing. J Pharm Pharmacol 2016; 68:890-900. [DOI: 10.1111/jphp.12569] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2015] [Accepted: 04/10/2016] [Indexed: 11/30/2022]
Abstract
Abstract
Objectives
The aim of this study was to develop mucoadhesive oral strips using hot-melt extrusion as a continuous manufacturing process.
Methods
Powder blends of ketoconazole, a water-insoluble drug – either hydroxypropyl methylcellulose (HPMC) or soluplus (SOL), sorbitol (SRB) and magnesium aluminometasilicate (MAS) were extruded to manufacture thin strips with 0.5-mm thickness. The presence of the inorganic metasilicate facilitated smooth processing of the extruded strips as it worked as an absorbent directly impacting on the extensive mixing of the drug/excipients inside the extruder barrel.
Key findings
The use of MAS also favoured the rapid hydration, swelling and eventual disintegration of the strips. Differential scanning calorimetry and transmission X-ray diffraction analysis revealed the existence of the amorphous drug within the extruded strips. Scanning electron microscopy and energy dispersive X-ray undertaken on the formulations showed a homogeneous drug distribution within the extruded strips.
Conclusion
The strips produced via continuous hot-melt extrusion processing showed significantly faster release of ketoconazole compared to the bulk drug substance.
Collapse
Affiliation(s)
- Mohammed Maniruzzaman
- Department of Pharmacy (Chemistry), School of Life Sciences, University of Sussex, Brighton, UK
| | - Smirna Farias
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham, Chatham Maritime, Kent, UK
| | - Ian J Slipper
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham, Chatham Maritime, Kent, UK
| | - Joshua S Boateng
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham, Chatham Maritime, Kent, UK
| | - Babur Z Chowdhry
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham, Chatham Maritime, Kent, UK
| | - Arun Nair
- Fuji Chemical Industry Co., Ltd., Minato-ku, Tokyo, Japan
| | - Dennis Douroumis
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham, Chatham Maritime, Kent, UK
| |
Collapse
|
4
|
Piccinni P, Tian Y, McNaughton A, Fraser J, Brown S, Jones DS, Li S, Andrews GP. Solubility parameter-based screening methods for early-stage formulation development of itraconazole amorphous solid dispersions. J Pharm Pharmacol 2016; 68:705-20. [PMID: 26864155 DOI: 10.1111/jphp.12491] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2015] [Accepted: 09/20/2015] [Indexed: 11/30/2022]
Abstract
Abstract
Objectives
This article uses conventional and newly extended solubility parameter (δ) methods to identify polymeric materials capable of forming amorphous dispersions with itraconazole (itz).
Methods
Combinations of itz and Soluplus, Eudragit E PO (EPO), Kollidon 17PF (17PF) or Kollidon VA64 (VA64) were prepared as amorphous solid dispersions using quench cooling and hot melt extrusion. Storage stability was evaluated under a range of conditions using differential scanning calorimetry and powder X-ray diffraction.
Key findings
The rank order of itz miscibility with polymers using both conventional and novel δ-based approaches was 17PF > VA64 > Soluplus > EPO, and the application of the Flory–Huggins lattice model to itz–excipient binary systems corroborated the findings. The solid-state characterisation analyses of the formulations manufactured by melt extrusion correlated well with pre-formulation screening. Long-term storage studies showed that the physical stability of 17PF/vitamin E TPGS–itz was poor compared with Soluplus and VA64 formulations, and for EPO/itz systems variation in stability may be observed depending on the preparation method.
Conclusion
Results have demonstrated that although δ-based screening may be useful in predicting the initial state of amorphous solid dispersions, assessment of the physical behaviour of the formulations at relevant temperatures may be more appropriate for the successful development of commercially acceptable amorphous drug products.
Collapse
Affiliation(s)
- Piero Piccinni
- Pharmaceutical Engineering Group, Queen's University, Belfast, UK
- Encap Drug Delivery, West Lothian, UK
| | - Yiwei Tian
- Pharmaceutical Engineering Group, Queen's University, Belfast, UK
| | | | | | | | - David S Jones
- Pharmaceutical Engineering Group, Queen's University, Belfast, UK
| | - Shu Li
- Pharmaceutical Engineering Group, Queen's University, Belfast, UK
| | - Gavin P Andrews
- Pharmaceutical Engineering Group, Queen's University, Belfast, UK
| |
Collapse
|
5
|
Islam MT, Scoutaris N, Maniruzzaman M, Moradiya HG, Halsey SA, Bradley MSA, Chowdhry BZ, Snowden MJ, Douroumis D. Implementation of transmission NIR as a PAT tool for monitoring drug transformation during HME processing. Eur J Pharm Biopharm 2015. [PMID: 26209124 DOI: 10.1016/j.ejpb.2015.06.021] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
The aim of the work reported herein was to implement process analytical technology (PAT) tools during hot melt extrusion (HME) in order to obtain a better understanding of the relationship between HME processing parameters and the extruded formulations. For the first time two in-line NIR probes (transmission and reflectance) have been coupled with HME to monitor the extrusion of the water insoluble drug indomethacin (IND) in the presence of Soluplus (SOL) or Kollidon VA64 hydrophilic polymers. In-line extrusion monitoring of sheets, produced via a specially designed die, was conducted at various drug/polymer ratios and processing parameters. Characterisation of the extruded transparent sheets was also undertaken by using DSC, XRPD and Raman mapping. Analysis of the experimental findings revealed the production of molecular solutions where IND is homogeneously blended (ascertained by Raman mapping) in the polymer matrices, as it acts as a plasticizer for both hydrophilic polymers. PCA analysis of the recorded NIR signals showed that the screw speed used in HME affects the recorded spectra but not the homogeneity of the embedded drug in the polymer sheets. The IND/VA64 and IND/SOL extruded sheets displayed rapid dissolution rates with 80% and 30% of the IND being released, respectively within the first 20min.
Collapse
Affiliation(s)
- Muhammad T Islam
- Faculty of Engineering and Science, University of Greenwich, Medway Campus, Chatham Maritime, Kent ME4 4TB, UK
| | - Nikolaos Scoutaris
- Faculty of Engineering and Science, University of Greenwich, Medway Campus, Chatham Maritime, Kent ME4 4TB, UK
| | - Mohammed Maniruzzaman
- Faculty of Engineering and Science, University of Greenwich, Medway Campus, Chatham Maritime, Kent ME4 4TB, UK
| | - Hiren G Moradiya
- Faculty of Engineering and Science, University of Greenwich, Medway Campus, Chatham Maritime, Kent ME4 4TB, UK
| | - Sheelagh A Halsey
- ThermoFisher Scientific, Stafford House, Boundary Way, Hemel Hempstead HP2 7GE, UK
| | - Michael S A Bradley
- Faculty of Engineering and Science, University of Greenwich, Medway Campus, Chatham Maritime, Kent ME4 4TB, UK
| | - Babur Z Chowdhry
- Faculty of Engineering and Science, University of Greenwich, Medway Campus, Chatham Maritime, Kent ME4 4TB, UK
| | - Martin J Snowden
- Faculty of Engineering and Science, University of Greenwich, Medway Campus, Chatham Maritime, Kent ME4 4TB, UK
| | - Dennis Douroumis
- Faculty of Engineering and Science, University of Greenwich, Medway Campus, Chatham Maritime, Kent ME4 4TB, UK.
| |
Collapse
|
6
|
Thiry J, Krier F, Evrard B. A review of pharmaceutical extrusion: critical process parameters and scaling-up. Int J Pharm 2014; 479:227-40. [PMID: 25541517 DOI: 10.1016/j.ijpharm.2014.12.036] [Citation(s) in RCA: 102] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2014] [Revised: 12/15/2014] [Accepted: 12/16/2014] [Indexed: 11/30/2022]
Abstract
Hot melt extrusion has been a widely used process in the pharmaceutical area for three decades. In this field, it is important to optimize the formulation in order to meet specific requirements. However, the process parameters of the extruder should be as much investigated as the formulation since they have a major impact on the final product characteristics. Moreover, a design space should be defined in order to obtain the expected product within the defined limits. This gives some freedom to operate as long as the processing parameters stay within the limits of the design space. Those limits can be investigated by varying randomly the process parameters but it is recommended to use design of experiments. An examination of the literature is reported in this review to summarize the impact of the variation of the process parameters on the final product properties. Indeed, the homogeneity of the mixing, the state of the drug (crystalline or amorphous), the dissolution rate, the residence time, can be influenced by variations in the process parameters. In particular, the impact of the following process parameters: temperature, screw design, screw speed and feeding, on the final product, has been reviewed.
Collapse
Affiliation(s)
- J Thiry
- University of Liege (ULg), Department of Pharmacy, CIRM, Laboratory of Pharmaceutical Technology and Biopharmacy, CHU, Avenue de l'Hopital 1, B36, B-4000 Liege, Belgium.
| | - F Krier
- University of Liege (ULg), Department of Pharmacy, CIRM, Laboratory of Pharmaceutical Technology and Biopharmacy, CHU, Avenue de l'Hopital 1, B36, B-4000 Liege, Belgium
| | - B Evrard
- University of Liege (ULg), Department of Pharmacy, CIRM, Laboratory of Pharmaceutical Technology and Biopharmacy, CHU, Avenue de l'Hopital 1, B36, B-4000 Liege, Belgium
| |
Collapse
|