1
|
Cooper JL, Sharp CR, Boyd CJ, Claus MA, Rossi G. The hemostatic profile of cold-stored whole blood from non-greyhound and greyhound dogs over 42 days. Front Vet Sci 2023; 10:1135880. [PMID: 36937016 PMCID: PMC10019821 DOI: 10.3389/fvets.2023.1135880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Accepted: 02/08/2023] [Indexed: 03/06/2023] Open
Abstract
Objectives To compare the hemostatic characteristics of cold-stored whole blood (CSWB) from non-greyhound dogs (NGD) and greyhound dogs (GD) over 42 days of storage, notably, platelet closure time (PCT) (NGD only), manual platelet count (PLT) (GD only), ellagic acid (INTEM) and tissue factor activated (EXTEM) rotational thromboelastometry, prothrombin (PT) and activated partial thromboplastin time (aPTT), fibrinogen concentration (FIB), and the activities of factors (F) FII, FV, FVII, FVIII, FIX, FX, FXIII antigen (FXIII:Ag), and von Willebrand factor antigen (vWF:Ag). Design Whole blood from 10 NGD and 10 GD, was refrigerated in CPD blood bags at 4°C for 42 days. Blood was analyzed before refrigeration (day 0) and at day 1 (d1), 3, 5, 7, 10, 14, 17, 21, 24, 28, 31, 35, 38, and 42. Multivariate linear mixed effects models were created to evaluate coagulation parameters over time and compare NGD and GD. Data are summarized as estimated marginal means with 95% confidence intervals. Significance was set at P < 0.05. Results The PCT for all NGD CSWB was above the device limit by d7. The PLT for GD CSWB did not change during storage. The mean alpha-angle for INTEM and EXTEM decreased to <50% of baseline at d38 and d31 for NGD, and d31 and d17 for GD CSWB. The mean maximum clot firmness (MCF) for INTEM and EXTEM reduced to <50% of baseline at d42 and d28 for both GD and NGD. PT and aPTT for NGD and GD increased over time. For NGD CSWB, the mean FVIII and vWF:Ag activities decreased to <50% of baseline at d7 and d28, respectively, and FIB reached 0.982 g/dL by d24. For GD CSWB, FVIII, FXIII:Ag and FV activities decreased to <50% of baseline by d3, d38, and d38, respectively, and FIB was 0.982 g/dL at baseline. Alpha-angle and MCF for both INTEM and EXTEM, and activities for FII, FV, FIX, FXIII:Ag were significantly lower, and vWF:Ag was significantly higher overall in GD CSWB compared with NGD. A significant difference in the pattern of change over time was detected between NGD and GD in EXTEM alpha-angle, INTEM and EXTEM MCF, FII, and FVIII activities. Conclusions The in vitro viscoelastic parameters of GD and NGD CSWB declines over 42 days, but numerous hemostatic parameters (INTEM and EXTEM alpha-angle and MCF, activity of FII, FV, FV, FVII, FIX, FX, FXIII:Ag, vWF:Ag, and FIB) remain within 50% of baseline for more than 14 days. CSWB from GD compared to NGD has reduced hemostatic activity overall, but a similar pattern of decline for most parameters over time.
Collapse
Affiliation(s)
- James L. Cooper
- School of Veterinary Medicine, Murdoch University, Murdoch, WA, Australia
| | - Claire R. Sharp
- School of Veterinary Medicine, Murdoch University, Murdoch, WA, Australia
- *Correspondence: Claire R. Sharp
| | - Corrin J. Boyd
- School of Veterinary Medicine, Murdoch University, Murdoch, WA, Australia
| | - Melissa A. Claus
- School of Veterinary Medicine, Murdoch University, Murdoch, WA, Australia
- Perth Veterinary Specialists, Osborne Park, WA, Australia
| | - Gabriel Rossi
- School of Veterinary Medicine, Murdoch University, Murdoch, WA, Australia
| |
Collapse
|
2
|
Blasi-Brugué C, Ferreira RRF, Sanchez IM, de Matos AJF, Ruiz de Gopegui R. Stability of coagulation factors in feline fresh frozen plasma intended for transfusion after 1 year of storage. J Feline Med Surg 2022; 24:e353-e359. [PMID: 36047983 PMCID: PMC10812320 DOI: 10.1177/1098612x221114630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
OBJECTIVES The most common use of plasma transfusion is for haemostatic purposes, but coagulation factor activities in stored feline plasma are unknown. The concentration and stability of coagulation factors I (fibrinogen), II, V, VII, VIII, IX, X, XI and XII in feline fresh frozen plasma (fFFP) stored for 1 year were studied. METHODS Fifty-five units of fFFP were produced from 55 fresh whole-blood donations obtained from indoor healthy blood donor cats. Twenty-one units were stored for <2 weeks (T0) and 34 were stored for 1 year (T1). After the completion of storage, specific coagulation factor activities for factors II, V, VII, VIII, IX, X, XI and XII were tested using modified one-stage activated partial thromboplastin or prothrombin time assays. Fibrinogen was determined using the Clauss method. RESULTS Significantly decreased activities were observed for factors II (T0: 101.94% ± 19.06%; T1: 73.23% ± 39.06% [P = 0.001]), VII (T0: 102.78% ± 24.69%; T1: 60.08% ± 38.17% [P <0.001]), VIII (T0: 77.52% ± 30.39%; T1: 50.32% ± 23.8% [P = 0.001]), XI (T0: 88.76% ± 22.73%; T1: 66.28% ± 22.2% [P = 0.001]) and XII (T0: 89.50% ± 21.85%; T1: 55.46% ± 23.18% [P <0.001]) when comparing units at time 0 and after 1 year of storage. No significant difference was observed for factors IX (T0: 84.86% ± 29.35%; T1: 71.37% ± 22.23% [P = 0.064]) and X (T0: 96.24% ± 25.1%; T1: 83.91% ± 49.54% [P = 0.236]). Unexpectedly, a significant increase was observed for factor V (T0: 71.94% ± 24.14%; T1: 97.89% ± 62.33%; P = 0.046). Fibrinogen was 2.76 ± 1.09 g/l at T1. Factors VIII, XII and VII had the lowest mean activities after 1 year. CONCLUSIONS AND RELEVANCE Although a decrease in most coagulation factors activities was noted with storage, 1-year-old fFFP was haemostatically active in vitro. The most suitable factors for quality control assessment of fFFP are factors VII and VIII. Approximately 13-20 ml/kg of fFFP is required to administer a minimum of 10 IU/kg coagulation factor activity.
Collapse
Affiliation(s)
- Carles Blasi-Brugué
- Department of Animal Medicine and Surgery, Veterinary Faculty, Autonomous University of Barcelona, Barcelona, Spain
| | - Rui RF Ferreira
- Animal Blood Bank, Barcelona, Spain
- Animal Blood Bank, Porto, Portugal
| | - Ignacio M Sanchez
- Animal Blood Bank, Barcelona, Spain
- Department of Internal Medicine, Hospital Aúna Veterinary Specialties, Valencia, Spain
| | - Augusto JF de Matos
- Animal Science and Study Centre, Food and Agrarian Sciences and Technologies Institute, University of Porto, Porto, Portugal
- Department of Veterinary Clinics, Institute for Biomedical Sciences of Abel Salazar, University of Porto, Porto, Portugal
| | - Rafael Ruiz de Gopegui
- Department of Animal Medicine and Surgery, Veterinary Faculty, Autonomous University of Barcelona, Barcelona, Spain
| |
Collapse
|
3
|
De Pablo-Moreno JA, Liras A, Revuelta L. Standardization of Coagulation Factor V Reference Intervals, Prothrombin Time, and Activated Partial Thromboplastin Time in Mice for Use in Factor V Deficiency Pathological Models. Front Vet Sci 2022; 9:846216. [PMID: 35419447 PMCID: PMC8995772 DOI: 10.3389/fvets.2022.846216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Accepted: 02/28/2022] [Indexed: 11/13/2022] Open
Abstract
Factor V together with activated factor X forms the prothrombinase complex, which transforms prothrombin into thrombin. The Mus musculus species is characterized by very high levels of this factor and short clotting times, which hinders accurate measurements. For that reason, a detailed characterization of such parameters is indispensable. A method was designed as part of this study to provide an accurate determination and standardization of factor V levels, prothrombin time and activated partial thromboplastin time in Mus musculus. Those parameters were evaluated in a sample of 66 healthy animals using a semi-automated coagulometer and human diagnostic reagents in an attempt to determine the most appropriate time of day for the extractions. A mouse-based protocol was designed, capable of making corrections to the samples at dilutions of 1:100 for factor V and at of 1:3 for prothrombin time. The goal was to smoothen the calibration curves, which often present with steep slopes and narrow measurement ranges between one calibration point and another. It was found that the most stable period for blood sample extraction was that comprised between the first 6 h of light. No clinical differences were observed between the sexes and reference intervals were established for factor V (95.80% ± 18.14; 25.21 s ± 1.34), prothrombin time (104.31% ± 14.52; 16.85 s ± 1.32) and activated partial thromboplastin time (32.86 s ± 3.01). The results obtained are applicable to human or veterinary biomedical research, to transfusional medicine or to pathological models for diseases such as factor V deficiency.
Collapse
Affiliation(s)
- Juan A. De Pablo-Moreno
- Department of Genetics, Physiology and Microbiology, School of Biology, Complutense University, Madrid, Spain
| | - Antonio Liras
- Department of Genetics, Physiology and Microbiology, School of Biology, Complutense University, Madrid, Spain
- *Correspondence: Antonio Liras
| | - Luis Revuelta
- Department of Physiology, School of Veterinary Medicine, Complutense University of Madrid, Madrid, Spain
| |
Collapse
|
4
|
Proverbio D, Perego R, Baggiani L, Spada E. Hemostatic Activity of Canine Never-Frozen Liquid Plasma Collected for Transfusion. Front Vet Sci 2022; 9:731617. [PMID: 35242834 PMCID: PMC8887598 DOI: 10.3389/fvets.2022.731617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Accepted: 01/20/2022] [Indexed: 11/22/2022] Open
Abstract
This study measured the changes of hemostatic activity in liquid plasma (LP) over 7 days of storage. Five canine plasma units, divided into two aliquots were evaluated: one stored refrigerated at 2–6°C as never-frozen LP and one frozen at −18°C as fresh frozen plasma (FFP). Clotting times, coagulation activities of factor (F) V, VIII, X, XI, antithrombin (AT), and von Willebrand (vWF), fibrinogen and D-dimers (DD) content were assessed before storage (baseline value), and after 12, 24, 48 h and 7 days (D7) in LP stored refrigerated, and on day 7 in FFP. At baseline median values of all factor activity were greater than 80%, and for clotting times, AT, fibrinogen and DD content, were within the canine reference range. Some hemostatic parameters changed significantly over 7 days and at the end of storage in LP. However, median activities of FV, FVIII, FX and FXI, coagulation time, AT, fibrinogen and DD content remained within reference ranges at all time points. The only exception was for vWF which median activity was lower than reference range for all storage time points. Activity of FVIII was significant lower in LP at D7 when compared to activity in FFP, with values of 62 vs. 118%, respectively. DD content showed a median value higher than reference range in FFP at D7. Despite some statistically significant changes at the end of 7-day storage period, never-frozen LP maintained median factor activities >80% for most factors. The clinical impact of the drop over time of vWF activity is unknown.
Collapse
|
5
|
Edwards TH, Darlington DN, Pusateri AE, Keesee JD, Ruiz DD, Little JS, Parker JS, Cap AP. Hemostatic capacity of canine chilled whole blood over time. J Vet Emerg Crit Care (San Antonio) 2021; 31:239-246. [PMID: 33709546 DOI: 10.1111/vec.13055] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Revised: 07/10/2019] [Accepted: 08/12/2019] [Indexed: 12/12/2022]
Abstract
OBJECTIVE To determine the hemostatic potential of canine chilled whole blood maintained at clinically relevant storage conditions. DESIGN In vitro experimental study. SETTING Government blood and coagulation research laboratory and government referral veterinary hospital. ANIMALS Ten healthy Department of Defense military working dogs. INTERVENTIONS One unit of fresh whole blood was collected from each of 10 military working dogs using aseptic technique. Blood was maintained in a medical-grade refrigerator for 28 days at 4°C (39°F) and analyzed before refrigeration (day 0) and after (days 2, 4, 7, 9, 11, 14, 21, and 28). MEASUREMENTS AND MAIN RESULTS Ten units of canine blood were analyzed with whole blood platelet aggregation, thromboelastography, CBC, biochemical analysis, blood gas, and prothrombin/activated partial thromboplastin/fibrinogen assay. Clotting strength of chilled blood was maintained up to 21 days despite significant decreases in platelet aggregation to ADP, collagen, or γ-thrombin, significant prolongation of prothrombin and activated partial thromboplastin times, and reduced speed of clot formation (K time, alpha angle). Fibrinogen concentration, WBC, RBC, and platelet counts did not change over time. CONCLUSIONS Chilled canine whole blood loses a small percentage of clot strength through 21 days of refrigerated storage. Further research is needed to determine if this hemostatic potential is clinically relevant in hemorrhaging dogs who require surgical intervention or are exposed to traumatic events.
Collapse
Affiliation(s)
- Thomas H Edwards
- US Army Institute of Surgical Research, Joint Base San Antonio, Fort Sam Houston, Texas, USA
| | - Daniel N Darlington
- US Army Institute of Surgical Research, Joint Base San Antonio, Fort Sam Houston, Texas, USA
| | - Anthony E Pusateri
- US Army Institute of Surgical Research, Joint Base San Antonio, Fort Sam Houston, Texas, USA
| | - Jeffrey D Keesee
- US Army Institute of Surgical Research, Joint Base San Antonio, Fort Sam Houston, Texas, USA
| | - Daikor D Ruiz
- US Army Institute of Surgical Research, Joint Base San Antonio, Fort Sam Houston, Texas, USA
| | - Joshua S Little
- US Army Institute of Surgical Research, Joint Base San Antonio, Fort Sam Houston, Texas, USA
| | - Jacquelyn S Parker
- Department of Defense Military Working Dog Veterinary Service, Joint Base San Antonio-Lackland, Texas, USA
| | - Andrew P Cap
- US Army Institute of Surgical Research, Joint Base San Antonio, Fort Sam Houston, Texas, USA
| |
Collapse
|
6
|
Foote ML, Brooks MB, Archer TM, Wills RW, Mackin AJ, Thomason JM. Coagulation factor activity in units of leukoreduced and nonleukoreduced canine fresh-frozen plasma. Am J Vet Res 2019; 80:846-851. [PMID: 31449444 DOI: 10.2460/ajvr.80.9.846] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate coagulation factors in units of leukoreduced (LR) and nonleukoreduced (non-LR) canine fresh-frozen plasma (cFFP). ANIMALS 8 healthy research dogs. PROCEDURES In a crossover study, dogs were randomly assigned to 1 of 2 groups from which blood was collected and either did or did not undergo leukoreduction. After a recovery period of ≥ 28 days, the dogs were switched between protocols. After each collection, blood samples were centrifuged, and cFFP was stored frozen for later comparative analysis of coagulation factors, antithrombin, and protein C activities (reported as comparative percentages of the corresponding activities determined in a canine pooled plasma standard); prothrombin and activated partial thromboplastin times; and fibrinogen concentration. RESULTS There were no significant differences detected between results for LR cFFP, compared with those for non-LR cFFP. CONCLUSIONS AND CLINICAL RELEVANCE Although there was variation among residual activities of coagulation factors in LR and non-LR cFFP, the variations and differences were considered unlikely to impact the efficacy of LR cFFP transfused for coagulation factor replacement in dogs. However, owing to the small sample size and high variability of results in the present study, additional research with a larger sample size is required for definitive conclusions on the effects of leukoreduction on coagulation factors in cFFP and to develop treatment guidelines for LR cFFP use in dogs with congenital and acquired coagulopathies.
Collapse
|
7
|
Donahue ME, Fernandez AL. Effects of storage over a 36-month period on coagulation factors in a canine plasma product obtained by use of plasmapheresis. Am J Vet Res 2019; 80:578-585. [PMID: 31140844 DOI: 10.2460/ajvr.80.6.578] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate stability of coagulation factors in canine plasma obtained by use of plasmapheresis and stored over a 36-month period. SAMPLE Canine plasma obtained by use of plasmapheresis acquired from a commercial blood bank. PROCEDURES Coagulation testing for fibrinogen concentration and activity of factors II, V, VII, VIII, and IX and von Willebrand factor was performed on canine plasma obtained by use of plasmapheresis. Samples were obtained for testing at 6-month intervals from plasma stored for up to 36 months. RESULTS A simple mixed linear regression model was created for each analysis. Median value for the fibrinogen concentration was > 150 mg/dL for all time points, except at 467, 650, and 1,015 days of storage. Median value for factor VIII was > 70% only at 650 days. Median value for factor V was > 50% through 650 days. Median value for factors VII and X was > 50% through 833 days, and median value for factors II and VII was > 50% through 1,015 days. Median value for von Willebrand factor was > 50% for the entire study (1,198 days). Median value for factor X was always < 50%. CONCLUSIONS AND CLINICAL RELEVANCE Coagulation factors degraded over time at variable rates, and all labile factors remained at > 50% activity for longer than 1 year. Plasma collected by plasmapheresis potentially offers prolonged life span of some clotting factors. Plasmapheresis is an acceptable form of canine plasma collection for transfusion purposes, and further studies should be performed to determine all of its benefits.
Collapse
|
8
|
Lehmann H, Hindricks E, Hassdenteufel EM, Moritz A, Bauer N. Prospective Comparative Quality Control Study of a Novel Gravity-Driven Hollow-Fiber Whole Blood Separation System for the Production of Canine Blood Products. Front Vet Sci 2019; 6:149. [PMID: 31157246 PMCID: PMC6533853 DOI: 10.3389/fvets.2019.00149] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2018] [Accepted: 04/29/2019] [Indexed: 12/02/2022] Open
Abstract
The aim of this prospective study was to compare quality of blood products produced either by a novel gravity-driven hollow-fiber separation system (HF) or by centrifugation (C). Whole blood was obtained from 31 healthy non-greyhound canine blood donors and separated into fresh frozen plasma and packed red blood cells using either HF or C in a university teaching hospital. Red blood cell (RBC) count, albumin and fibrinogen concentration, prothrombin time (PT), activated partial thromboplastin time (aPTT) and coagulation factor activity (FV, FVIII), von Willebrand Factor (vWF), and antithrombin activity were assessed. Plasma obtained with the HF showed a significantly higher median PT (9.4 vs. 7.9 s, P = 0.0006) and aPTT (14.9 vs. 13.1 s, P = 0.0128) than plasma prepared with C. Lower albumin (21.7 vs. 23.5 g/l, P = 0.0162) and fibrinogen (1.0 vs. 1.5 g/l, P = 0.0005) concentrations and activities of FV (105 vs. 114%, P = 0.0021) and antithrombin (104 vs. 117%, P = 0.0024) were seen in blood products obtained with the HF. In contrast, vWF was not affected by the method of plasma separation. Compared to HF, RBC count as well as hematocrit were not significantly higher (8.0 vs. 8.9 1012/l, P = 0.1308; 0.57 vs. 0.62 l/l, P = 0.0736) when blood products were prepared with C. In conclusion, higher quality of blood products especially regarding coagulation parameters and RBCs was achieved by using C compared to HF. Despite the statistical significances, however, the clinical relevance has to be further elucidated. Nevertheless, HF provides an alternative to produce blood products if a centrifuge is not available.
Collapse
Affiliation(s)
- Hendrik Lehmann
- Department of Veterinary Clinical Sciences, Small Animal Clinic, Justus-Liebig-University Giessen, Giessen, Germany
| | - Esther Hindricks
- Department of Veterinary Clinical Sciences, Clinical Pathology and Clinical Pathophysiology, Justus-Liebig-University Giessen, Giessen, Germany
| | - Esther Maria Hassdenteufel
- Department of Veterinary Clinical Sciences, Small Animal Clinic, Justus-Liebig-University Giessen, Giessen, Germany
| | - Andreas Moritz
- Department of Veterinary Clinical Sciences, Clinical Pathology and Clinical Pathophysiology, Justus-Liebig-University Giessen, Giessen, Germany
| | - Natali Bauer
- Department of Veterinary Clinical Sciences, Clinical Pathology and Clinical Pathophysiology, Justus-Liebig-University Giessen, Giessen, Germany
| |
Collapse
|
9
|
Yang W, Hosgood G, Luobikis K, Paul A. Agreement of point-of-care prothrombin and activated partial thromboplastin time in dogs with a reference laboratory. Aust Vet J 2018; 96:379-384. [DOI: 10.1111/avj.12746] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2017] [Revised: 03/23/2018] [Accepted: 07/02/2018] [Indexed: 11/27/2022]
Affiliation(s)
- W Yang
- The Animal Hospital Murdoch University, Murdoch Dr; Murdoch Western Australia 6150 Australia
| | - G Hosgood
- The Animal Hospital Murdoch University, Murdoch Dr; Murdoch Western Australia 6150 Australia
| | - K Luobikis
- The Animal Hospital Murdoch University, Murdoch Dr; Murdoch Western Australia 6150 Australia
| | - A Paul
- Anderson Moores Veterinary Specialists Ltd; Winchester UK
| |
Collapse
|
10
|
Goggs R, Borrelli A, Brainard BM, Chan DL, de Laforcade A, Goy-Thollot I, Jandrey KE, Kristensen AT, Kutter A, Marschner CB, Rannou B, Sigrist N, Wagg C. Multicenter in vitro thromboelastography and thromboelastometry standardization. J Vet Emerg Crit Care (San Antonio) 2018; 28:201-212. [DOI: 10.1111/vec.12710] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2016] [Revised: 02/22/2017] [Accepted: 03/30/2017] [Indexed: 11/27/2022]
Affiliation(s)
- Robert Goggs
- Department of Clinical Sciences, College of Veterinary Medicine; Cornell University; Ithaca NY
| | - Antonio Borrelli
- Department of Veterinary Science; University of Turin; Grugliasco Italy
| | | | - Daniel L. Chan
- Department of Clinical Sciences and Services; Royal Veterinary College; London UK
| | | | | | | | | | - Annette Kutter
- Vetsuisse Faculty; University of Zurich; Zurich Switzerland
| | - Clara B. Marschner
- Department of Veterinary Clinical and Animal Sciences; University of Copenhagen; Denmark
| | - Benoît Rannou
- VetAgro Sup; Campus Vétérinaire de Lyon; Marcy l′Étoile France
| | - Nadja Sigrist
- Vetsuisse Faculty; University of Zurich; Zurich Switzerland
| | | |
Collapse
|
11
|
Chan KSK, Sparrow RL. Microparticle profile and procoagulant activity of fresh-frozen plasma is affected by whole blood leukoreduction rather than 24-hour room temperature hold. Transfusion 2014; 54:1935-44. [PMID: 24635475 DOI: 10.1111/trf.12602] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2013] [Revised: 01/07/2014] [Accepted: 01/10/2014] [Indexed: 02/06/2023]
Abstract
BACKGROUND Microparticles (MPs) are small phospholipid-containing vesicles that have procoagulant properties. MPs are thought to contribute to the hemostatic potential of plasma. This study investigated the effects of whole blood (WB) hold time and leukoreduction (LR) on the MP profile and hemostatic potential of fresh-frozen plasma (FFP). STUDY DESIGN AND METHODS WB units (n=12) from healthy donors were divided into two pairs and each pair was held at 20 to 24°C for 6 or 24 hours. At the designated hold time, 1 unit from the pair was LR while the other unit was not LR. FFP was prepared by standard procedures, aliquoted, and frozen. The MP content was determined by flow cytometry using an absolute count assay and specific labels for red blood cells (CD235a), platelets (CD41), and phosphatidylserine (PS). The hemostatic potential was determined by thrombelastography (TEG) and coagulation factor assays. RESULTS Compared to non-LR-FFP, LR-FFP had significantly lower numbers of MPs, particularly CD41+ MPs and PS-positive MPs (p<0.03). LR-FFP, compared to non-LR-FFP, had a slower clot formation time (p=0.002); lower clot strength (p<0.001); and lower Factor (F)VIII, FXII, and fibrinogen levels (p<0.01). With longer WB hold time, the TEG profile was unchanged, although FVIII levels were decreased as expected (p<0.01). On average FFP units met quality requirements. CONCLUSION LR of WB resulted in lower hemostatic potential of FFP in conjunction with depletion of MPs and coagulation factors. Longer WB hold time did not significantly affect the hemostatic potential of FFP as measured by TEG. Acceptable hemostatic quality was maintained for all FFP processing conditions studied.
Collapse
Affiliation(s)
- Kasey Sze-Kei Chan
- Research and Development, Australian Red Cross Blood Service, Melbourne, Victoria, Australia
| | | |
Collapse
|
12
|
Kisielewicz C, Self IA. Canine and feline blood transfusions: controversies and recent advances in administration practices. Vet Anaesth Analg 2014; 41:233-42. [PMID: 24576208 DOI: 10.1111/vaa.12135] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2013] [Accepted: 11/15/2013] [Indexed: 11/28/2022]
Abstract
OBJECTIVES To discuss and review blood transfusion practices in dogs and cats including collection and storage of blood and administration of products. To report new developments, controversial practices, less conventional blood product administration techniques and where applicable, describe the relevance to anaesthetists and anaesthesia. DATABASES USED PubMed and Google Scholar using dog, cat, blood transfusion, packed red blood cells and whole blood as keywords. CONCLUSIONS Blood transfusions improve oxygen carrying capacity and the clinical signs of anaemia. However there are numerous potential risks and complications possible with transfusions, which may outweigh their benefits. Storage of blood products has improved considerably over time but whilst extended storage times may improve their availability, a phenomenon known as the storage lesion has been identified which affects erythrocyte viability and survival. Leukoreduction involves removing leukocytes and platelets thereby preventing their release of cytokines and bioactive compounds which also contribute to storage lesions and certain transfusion reactions. Newer transfusion techniques are being explored such as cell salvage in surgical patients and subsequent autologous transfusion. Xenotransfusions, using blood and blood products between different species, provide an alternative to conventional blood products.
Collapse
Affiliation(s)
- Caroline Kisielewicz
- Queen Mother Hospital for Animals, Royal Veterinary College, Hatfield, Hertfordshire, UK
| | | |
Collapse
|