Quinn KN, Tian Y, Budde R, Irazoqui PP, Tuffaha S, Thakor NV. Neuromuscular implants: Interfacing with skeletal muscle for improved clinical translation of prosthetic limbs. Muscle Nerve 2024; 69:134-147. [PMID: 38126120 DOI: 10.1002/mus.28029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 11/27/2023] [Accepted: 12/10/2023] [Indexed: 12/23/2023]
Abstract
After an amputation, advanced prosthetic limbs can be used to interface with the nervous system and restore motor function. Despite numerous breakthroughs in the field, many of the recent research advancements have not been widely integrated into clinical practice. This review highlights recent innovations in neuromuscular implants-specifically those that interface with skeletal muscle-which could improve the clinical translation of prosthetic technologies. Skeletal muscle provides a physiologic gateway to harness and amplify signals from the nervous system. Recent surgical advancements in muscle reinnervation surgeries leverage the "bio-amplification" capabilities of muscle, enabling more intuitive control over a greater number of degrees of freedom in prosthetic limbs than previously achieved. We anticipate that state-of-the-art implantable neuromuscular interfaces that integrate well with skeletal muscle and novel surgical interventions will provide a long-term solution for controlling advanced prostheses. Flexible electrodes are expected to play a crucial role in reducing foreign body responses and improving the longevity of the interface. Additionally, innovations in device miniaturization and ongoing exploration of shape memory polymers could simplify surgical procedures for implanting such interfaces. Once implanted, wireless strategies for powering and transferring data from the interface can eliminate bulky external wires, reduce infection risk, and enhance day-to-day usability. By outlining the current limitations of neuromuscular interfaces along with potential future directions, this review aims to guide continued research efforts and future collaborations between engineers and specialists in the field of neuromuscular and musculoskeletal medicine.
Collapse
Affiliation(s)
- Kiara N Quinn
- Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland, USA
| | - Yucheng Tian
- Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland, USA
| | - Ryan Budde
- Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland, USA
| | - Pedro P Irazoqui
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, Maryland, USA
| | - Sami Tuffaha
- Department of Plastic and Reconstructive Surgery, Johns Hopkins School of Medicine, Baltimore, Maryland, USA
| | - Nitish V Thakor
- Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland, USA
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, Maryland, USA
| |
Collapse
|
2
|
Nazari V, Zheng YP. Controlling Upper Limb Prostheses Using Sonomyography (SMG): A Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:1885. [PMID: 36850483 PMCID: PMC9959820 DOI: 10.3390/s23041885] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 02/01/2023] [Accepted: 02/06/2023] [Indexed: 06/18/2023]
Abstract
This paper presents a critical review and comparison of the results of recently published studies in the fields of human-machine interface and the use of sonomyography (SMG) for the control of upper limb prothesis. For this review paper, a combination of the keywords "Human Machine Interface", "Sonomyography", "Ultrasound", "Upper Limb Prosthesis", "Artificial Intelligence", and "Non-Invasive Sensors" was used to search for articles on Google Scholar and PubMed. Sixty-one articles were found, of which fifty-nine were used in this review. For a comparison of the different ultrasound modes, feature extraction methods, and machine learning algorithms, 16 articles were used. Various modes of ultrasound devices for prosthetic control, various machine learning algorithms for classifying different hand gestures, and various feature extraction methods for increasing the accuracy of artificial intelligence used in their controlling systems are reviewed in this article. The results of the review article show that ultrasound sensing has the potential to be used as a viable human-machine interface in order to control bionic hands with multiple degrees of freedom. Moreover, different hand gestures can be classified by different machine learning algorithms trained with extracted features from collected data with an accuracy of around 95%.
Collapse
Affiliation(s)
- Vaheh Nazari
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | - Yong-Ping Zheng
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China
- Research Institute for Smart Ageing, The Hong Kong Polytechnic University, Hong Kong SAR, China
| |
Collapse
|
3
|
Gstoettner C, Festin C, Prahm C, Bergmeister KD, Salminger S, Sturma A, Hofer C, Russold MF, Howard CL, McDonnall D, Farina D, Aszmann OC. Feasibility of a Wireless Implantable Multi-electrode System for High-bandwidth Prosthetic Interfacing: Animal and Cadaver Study. Clin Orthop Relat Res 2022; 480:1191-1204. [PMID: 35202032 PMCID: PMC9263498 DOI: 10.1097/corr.0000000000002135] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 01/19/2022] [Indexed: 01/31/2023]
Abstract
BACKGROUND Currently used prosthetic solutions in upper extremity amputation have limited functionality, owing to low information transfer rates of neuromuscular interfacing. Although surgical innovations have expanded the functional potential of the residual limb, available interfaces are inefficacious in translating this potential into improved prosthetic control. There is currently no implantable solution for functional interfacing in extremity amputation which offers long-term stability, high information transfer rates, and is applicable for all levels of limb loss. In this study, we presented a novel neuromuscular implant, the the Myoelectric Implantable Recording Array (MIRA). To our knowledge, it is the first fully implantable system for prosthetic interfacing with a large channel count, comprising 32 intramuscular electrodes. QUESTIONS/PURPOSES The purpose of this study was to evaluate the MIRA in terms of biocompatibility, functionality, and feasibility of implantation to lay the foundations for clinical application. This was achieved through small- and large-animal studies as well as test surgeries in a human cadaver. METHODS We evaluated the biocompatibility of the system's intramuscular electromyography (EMG) leads in a rabbit model. Ten leads as well as 10 pieces of a biologically inert control material were implanted into the paravertebral muscles of four animals. After a 3-month implantation, tissue samples were taken and histopathological assessment performed. The probes were scored according to a protocol for the assessment of the foreign body response, with primary endpoints being inflammation score, tissue response score, and capsule thickness in µm. In a second study, chronic functionality of the full system was evaluated in large animals. The MIRA was implanted into the shoulder region of six dogs and three sheep, with intramuscular leads distributed across agonist and antagonist muscles of shoulder flexion. During the observation period, regular EMG measurements were performed. The implants were removed after 5 to 6 months except for one animal, which retained the implant for prolonged observation. Primary endpoints of the large-animal study were mechanical stability, telemetric capability, and EMG signal quality. A final study involved the development of test surgeries in a fresh human cadaver, with the goal to determine feasibility to implant relevant target muscles for prosthetic control at all levels of major upper limb amputation. RESULTS Evaluation of the foreign body reaction revealed favorable biocompatibility and a low-grade tissue response in the rabbit study. No differences regarding inflammation score (EMG 4.60 ± 0.97 [95% CI 4.00 to 5.20] versus control 4.20 ± 1.48 [95% CI 3.29 to 5.11]; p = 0.51), tissue response score (EMG 4.00 ± 0.82 [95% CI 3.49 to 4.51] versus control 4.00 ± 0.94 [95% CI 3.42 to 4.58]; p > 0.99), or thickness of capsule (EMG 19.00 ± 8.76 µm [95% CI 13.57 to 24.43] versus control 29.00 ± 23.31 µm [95% CI 14.55 to 43.45]; p = 0.29) were found compared with the inert control article (high-density polyethylene) after 3 months of intramuscular implantation. Throughout long-term implantation of the MIRA in large animals, telemetric communication remained unrestricted in all specimens. Further, the implants retained the ability to record and transmit intramuscular EMG data in all animals except for two sheep where the implants became dislocated shortly after implantation. Electrode impedances remained stable and below 5 kΩ. Regarding EMG signal quality, there was little crosstalk between muscles and overall average signal-to-noise ratio was 22.2 ± 6.2 dB. During the test surgeries, we found that it was possible to implant the MIRA at all major amputation levels of the upper limb in a human cadaver (the transradial, transhumeral, and glenohumeral levels). For each level, it was possible to place the central unit in a biomechanically stable environment to provide unhindered telemetry, while reaching the relevant target muscles for prosthetic control. At only the glenohumeral level, it was not possible to reach the teres major and latissimus dorsi muscles, which would require longer lead lengths. CONCLUSION As assessed in a combination of animal model and cadaver research, the MIRA shows promise for clinical research in patients with limb amputation, where it may be employed for all levels of major upper limb amputation to provide long-term stable intramuscular EMG transmission. CLINICAL RELEVANCE In our study, the MIRA provided high-bandwidth prosthetic interfacing through intramuscular electrode sites. Its high number of individual EMG channels may be combined with signal decoding algorithms for accessing spinal motor neuron activity after targeted muscle reinnervation, thus providing numerous degrees of freedom. Together with recent innovations in amputation surgery, the MIRA might enable improved control approaches for upper limb amputees, particularly for patients with above-elbow amputation where the mismatch between available control signals and necessary degrees of freedom for prosthetic control is highest.
Collapse
Affiliation(s)
- Clemens Gstoettner
- Clinical Laboratory for Bionic Extremity Reconstruction, Department of Plastic, Reconstructive and Aesthetic Surgery, Medical University of Vienna, Vienna, Austria
| | - Christopher Festin
- Clinical Laboratory for Bionic Extremity Reconstruction, Department of Plastic, Reconstructive and Aesthetic Surgery, Medical University of Vienna, Vienna, Austria
| | - Cosima Prahm
- Clinical Laboratory for Bionic Extremity Reconstruction, Department of Plastic, Reconstructive and Aesthetic Surgery, Medical University of Vienna, Vienna, Austria
- BG Trauma Clinic, Eberhard Karls University, Department for Plastic and Reconstructive Surgery, Tübingen, Germany
| | - Konstantin D. Bergmeister
- Clinical Laboratory for Bionic Extremity Reconstruction, Department of Plastic, Reconstructive and Aesthetic Surgery, Medical University of Vienna, Vienna, Austria
- Karl Landsteiner University of Health Sciences, Krems, Austria
- Department of Plastic, Aesthetic and Reconstructive Surgery, University Hospital St. Poelten, St. Poelten, Austria
| | - Stefan Salminger
- Clinical Laboratory for Bionic Extremity Reconstruction, Department of Plastic, Reconstructive and Aesthetic Surgery, Medical University of Vienna, Vienna, Austria
- Department of Plastic, Reconstructive and Aesthetic Surgery, Medical University of Vienna, Vienna, Austria
| | - Agnes Sturma
- Clinical Laboratory for Bionic Extremity Reconstruction, Department of Plastic, Reconstructive and Aesthetic Surgery, Medical University of Vienna, Vienna, Austria
- Department of Bioengineering, Imperial College London, London, UK
| | - Christian Hofer
- Clinical Laboratory for Bionic Extremity Reconstruction, Department of Plastic, Reconstructive and Aesthetic Surgery, Medical University of Vienna, Vienna, Austria
- Otto Bock Healthcare Products GmbH, Vienna, Austria
| | | | | | | | - Dario Farina
- Department of Bioengineering, Imperial College London, London, UK
| | - Oskar C. Aszmann
- Clinical Laboratory for Bionic Extremity Reconstruction, Department of Plastic, Reconstructive and Aesthetic Surgery, Medical University of Vienna, Vienna, Austria
- Department of Plastic, Reconstructive and Aesthetic Surgery, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
4
|
Segil JL, Lukyanenko P, Lambrecht J, Weir RFF, Tyler D. Comparison of Myoelectric Control Schemes for Simultaneous Hand and Wrist Movement using Chronically Implanted Electromyography: A Case Series . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:6224-6230. [PMID: 34892537 PMCID: PMC10964936 DOI: 10.1109/embc46164.2021.9630845] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
OBJECTIVE A current biomedical engineering challenge is the development of a system that allows fluid control of multi-functional prosthetic devices through a human-machine interface. Here we probe this challenge by studying two subjects with trans-radial limb loss as they control a virtual hand and wrist system using 6 or 8 chronically implanted intramuscular electromyographic (iEMG) signals. The subjects successfully controlled a 4, 5, and 6 Degrees of Freedom (DoF's) virtual hand and wrist systems to perform a target matching task. APPROACH Two control systems were evaluated where one tied EMG features directly to movement directions (Direct Control) and the other method determines user intent in the context of prior training data (Linear Interpolation). MAIN RESULTS Subjects successfully matched most targets with both controllers but differences were seen as the complexity of the virtual limb system increased. The Direct Control method encountered difficulty due to crosstalk at higher DoF's. The Linear Interpolation method reduced crosstalk effects and outperformed Direct Control at higher DoF's. This work also studied the use of the Postural Control Algorithm to control the hand postures simultaneously with wrist degrees of freedom. SIGNIFICANCE This work presents preliminary evidence that the PC algorithm can be used in conjunction with wrist control, that Direct Control with iEMG signals allows stable 4-DoF control, and that EMG pre-processing using the Linear Interpolation method can improve performance at 5 and 6-DoF's.
Collapse
|
5
|
Makowski N, Campean A, Lambrecht J, Buckett J, Coburn J, Hart R, Miller M, Montague F, Crish T, Fu M, Kilgore K, Peckham PH, Smith B. Design and Testing of Stimulation and Myoelectric Recording Modules in an Implanted Distributed Neuroprosthetic System. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:281-293. [PMID: 33729949 PMCID: PMC8344369 DOI: 10.1109/tbcas.2021.3066838] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Implantable motor neuroprostheses can restore functionality to individuals with neurological disabilities by electrically activating paralyzed muscles in coordinated patterns. The typical design of neuroprosthetic systems relies on a single multi-use device, but this limits the number of stimulus and sensor channels that can be practically implemented. To address this limitation, a modular neuroprosthesis, the "Networked Neuroprosthesis" (NNP), was developed. The NNP system is the first fully implanted modular neuroprosthesis that includes implantation of all power, signal processing, biopotential signal recording, and stimulating components. This paper describes the design of stimulation and recording modules, bench testing to verify stimulus outputs and appropriate filtering and recording, and validation that the components function properly while implemented in persons with spinal cord injury. The results of system testing demonstrated that the NNP was functional and capable of generating stimulus pulses and recording myoelectric, temperature, and accelerometer signals. Based on the successful design, manufacturing, and testing of the NNP System, multiple clinical applications are anticipated.
Collapse
|
6
|
Abstract
Historical evidence suggests that prostheses have been used since ancient Egyptian times. Prostheses were usually utilized for function and cosmetic appearances. Nowadays, with the advancement of technology, prostheses such as artificial hands can not only improve functional, but have psychological advantages as well and, therefore, can significantly enhance an individual’s standard of living. Combined with advanced science, a prosthesis is not only a simple mechanical device, but also an aesthetic, engineering and medical marvel. Prosthetic limbs are the best tools to help amputees reintegrate into society. In this article, we discuss the background and advancement of prosthetic hands with their working principles and possible future implications. We also leave with an open question to the readers whether prosthetic hands could ever mimic and replace our biological hands.
Collapse
|
7
|
Zheng XS, Griffith AY, Chang E, Looker MJ, Fisher LE, Clapsaddle B, Cui XT. Evaluation of a conducting elastomeric composite material for intramuscular electrode application. Acta Biomater 2020; 103:81-91. [PMID: 31863910 DOI: 10.1016/j.actbio.2019.12.021] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 11/25/2019] [Accepted: 12/10/2019] [Indexed: 01/14/2023]
Abstract
Electrical stimulation of the muscle has been proven efficacious in preventing atrophy and/or reanimating paralyzed muscles. Intramuscular electrodes made from metals have significantly higher Young's Moduli than the muscle tissues, which has the potential to cause chronic inflammation and decrease device performance. Here, we present an intramuscular electrode made from an elastomeric conducting polymer composite consisting of PEDOT-PEG copolymer, silicone and carbon nanotubes (CNT) with fluorosilicone insulation. The electrode wire has a Young's modulus of 804 (±99) kPa, which better mimics the muscle tissue modulus than conventional stainless steel (SS) electrodes. Additionally, the non-metallic composition enables metal-artifact free CT and MR imaging. These soft wire (SW) electrodes present comparable electrical impedance to SS electrodes of similar geometric surface area, activate muscle at a lower threshold, and maintain stable electrical properties in vivo up to 4 weeks. Histologically, the SW electrodes elicited significantly less fibrotic encapsulation and less IBA-1 positive macrophage accumulation than the SS electrodes at one and three months. Further phenotyping the macrophages with the iNOS (pro-inflammatory) and ARG-1 (pro-healing) markers revealed significantly less presence of pro-inflammatory macrophage around SW implants at one month. By three months, there was a significant increase in pro-healing macrophages (ARG-1) around the SW implants but not around the SS implants. Furthermore, a larger number of AchR clusters closer to SW implants were found at both time points compared to SS implants. These results suggest that a softer implant encourages a more intimate and healthier electrode-tissue interface. STATEMENT OF SIGNIFICANCE: Intramuscular electrodes made from metals have significantly higher Young's Moduli than the muscle tissues, which has the potential to cause chronic inflammation and decrease device performance. Here, we present an intramuscular electrode made from an elastomeric conducting polymer composite consisting of PEDOT-PEG copolymer, silicone and carbon nanotubes with fluorosilicone insulation. This elastomeric composite results in an electrode wire with a Young's modulus mimicking that of the muscle tissue, which elicits significantly less foreign body response compared to stainless steel wires. The lack of metal in this composite also enables metal-artifact free MRI and CT imaging.
Collapse
Affiliation(s)
- X Sally Zheng
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States
| | - Azante Y Griffith
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States
| | - Emily Chang
- TDA Research Inc., Wheat Ridge, CO 80033, United States
| | | | - Lee E Fisher
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States; Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA 15213, United States; Center for Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA, United States
| | | | - X Tracy Cui
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States; Center for Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA, United States; McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, United States.
| |
Collapse
|
8
|
Stable, three degree-of-freedom myoelectric prosthetic control via chronic bipolar intramuscular electrodes: a case study. J Neuroeng Rehabil 2019; 16:147. [PMID: 31752886 PMCID: PMC6868792 DOI: 10.1186/s12984-019-0607-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Accepted: 10/10/2019] [Indexed: 11/30/2022] Open
Abstract
Background Modern prosthetic hands are typically controlled using skin surface electromyographic signals (EMG) from remaining muscles in the residual limb. However, surface electrode performance is limited by changes in skin impedance over time, day-to-day variations in electrode placement, and relative motion between the electrodes and underlying muscles during movement: these limitations require frequent retraining of controllers. In the presented study, we used chronically implanted intramuscular electrodes to minimize these effects and thus create a more robust prosthetic controller. Methods A study participant with a transradial amputation was chronically implanted with 8 intramuscular EMG electrodes. A K Nearest Neighbor (KNN) regression velocity controller was trained to predict intended joint movement direction using EMG data collected during a single training session. The resulting KNN was evaluated over 12 weeks and in multiple arm posture configurations, with the participant controlling a 3 Degree-of-Freedom (DOF) virtual reality (VR) hand to match target VR hand postures. The performance of this EMG-based controller was compared to a position-based controller that used movement measured from the participant’s opposite (intact) hand. Surface EMG was also collected for signal quality comparisons. Results Signals from the implanted intramuscular electrodes exhibited less crosstalk between the various channels and had a higher Signal-to-Noise Ratio than surface electrode signals. The performance of the intramuscular EMG-based KNN controller in the VR control task showed no degradation over time, and was stable over the 6 different arm postures. Both the EMG-based KNN controller and the intact hand-based controller had 100% hand posture matching success rates, but the intact hand-based controller was slightly superior in regards to speed (trial time used) and directness of the VR hand control (path efficiency). Conclusions Chronically implanted intramuscular electrodes provide negligible crosstalk, high SNR, and substantial VR control performance, including the ability to use a fixed controller over 12 weeks and under different arm positions. This approach can thus be a highly effective platform for advanced, multi-DOF prosthetic control.
Collapse
|
9
|
Vu PP, Irwin ZT, Bullard AJ, Ambani SW, Sando IC, Urbanchek MG, Cederna PS, Chestek CA. Closed-Loop Continuous Hand Control via Chronic Recording of Regenerative Peripheral Nerve Interfaces. IEEE Trans Neural Syst Rehabil Eng 2019; 26:515-526. [PMID: 29432117 DOI: 10.1109/tnsre.2017.2772961] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Loss of the upper limb imposes a devastating interruption to everyday life. Full restoration of natural arm control requires the ability to simultaneously control multiple degrees of freedom of the prosthetic arm and maintain that control over an extended period of time. Current clinically available myoelectric prostheses do not provide simultaneous control or consistency for transradial amputees. To address this issue, we have implemented a standard Kalman filter for continuous hand control using intramuscular electromyography (EMG) from both regenerative peripheral nerve interfaces (RPNI) and an intact muscle within non-human primates. Seven RPNIs and one intact muscle were implanted with indwelling bipolar intramuscular electrodes in two rhesus macaques. Following recuperations, function-specific EMG signals were recorded and then fed through the Kalman filter during a hand-movement behavioral task to continuously predict the monkey's finger position. We were able to reconstruct continuous finger movement offline with an average correlation of and a root mean squared error (RMSE) of 0.12 between actual and predicted position from two macaques. This finger movement prediction was also performed in real time to enable closed-loop neural control of a virtual hand. Compared with physical hand control, neural control performance was slightly slower but maintained an average target hit success rate of 96.70%. Recalibration longevity measurements maintained consistent average correlation over time but had a significant change in RMSE ( ). Additionally, extracted single units varied in amplitude by a factor of +18.65% and -25.85% compared with its mean. This is the first demonstration of chronic indwelling electrodes being used for continuous position control via the Kalman filter. Combining these analyses with our novel peripheral nerve interface, we believe that this demonstrates an important step in providing patients with more naturalistic control of their prosthetic limbs.
Collapse
|
10
|
Abstract
Neuromodulation, or the utilization of advanced technology for targeted electrical or chemical neuronal stimulation or inhibition, has been expanding in several neurological subspecialties. In the past decades, immune-modulating therapy has been the main focus of multiple sclerosis (MS) research with little attention to neuromodulation. However, with the recent advances in disease-modifying therapies, it is time to shift the focus of MS research to neuromodulation and restoration of function as with other neurological subspecialties. Preliminary research supports the value of intrathecal baclofen pump and functional electrical stimulation in improving spasticity and motor function in MS patients. Deep brain stimulation can improve MS-related tremor and trigeminal neuralgia. Spinal cord stimulation has been shown to be effective against MS-related pain and bladder dysfunction. Bladder overactivity also responds to sacral neuromodulation and posterior tibial nerve stimulation. Despite limited data in MS, transcranial magnetic stimulation and brain-computer interface are promising neuromodulatory techniques for symptom mitigation and neurorehabilitation of MS patients. In this review, we provide an overview of the available neuromodulatory techniques and the evidence for their use in MS.
Collapse
Affiliation(s)
- Hesham Abboud
- Multiple Sclerosis and Neuroimmunology Program, University Hospitals of Cleveland, Cleveland, OH, USA/School of Medicine, Case Western Reserve University, Cleveland, OH, USA/Neurology Department, Alexandria University, Alexandria, Egypt
| | - Eddie Hill
- School of Medicine, Case Western Reserve University, Cleveland, OH, USA
| | - Junaid Siddiqui
- Movement Disorders, University of Missouri- School of Medicine, Columbia, MO, USA
| | - Alessandro Serra
- Multiple Sclerosis and Neuroimmunology Program, University Hospitals of Cleveland, Cleveland, OH, USA/School of Medicine, Case Western Reserve University, Cleveland, OH, USA/Multiple Sclerosis Center of Excellence, Cleveland VA Medical Center Hub Site, East Cleveland, OH, USA
| | - Benjamin Walter
- School of Medicine, Case Western Reserve University, Cleveland, OH, USA/Parkinson's and Movement Disorders Center, University Hospitals of Cleveland, Cleveland, OH, USA
| |
Collapse
|
11
|
Neuroprosthetic Surgical Strategies for Neuromuscular Stimulation. Neuromodulation 2018. [DOI: 10.1016/b978-0-12-805353-9.00041-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
12
|
Restoring standing capabilities with feedback control of functional neuromuscular stimulation following spinal cord injury. Med Eng Phys 2017; 42:13-25. [PMID: 28215399 DOI: 10.1016/j.medengphy.2017.01.023] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2016] [Revised: 01/15/2017] [Accepted: 01/31/2017] [Indexed: 11/20/2022]
Abstract
This paper reviews the field of feedback control for neuroprosthesis systems that restore advanced standing function to individuals with spinal cord injury. Investigations into closed-loop control of standing by functional neuromuscular stimulation (FNS) have spanned three decades. The ultimate goal for FNS standing control systems is to facilitate hands free standing and enabling the user to perform manual functions at self-selected leaning positions. However, most clinical systems for home usage currently only provide basic upright standing using preprogrammed stimulation patterns. To date, online modulation of stimulation to produce advanced standing functions such as balance against postural disturbances or the ability to assume leaning postures have been limited to simulation and laboratory investigations. While great technological advances have been made in biomechanical sensing and interfaces for neuromuscular stimulation, further progress is still required for finer motor control by FNS. Another major challenge is the development of sophisticated control schemes that produce the necessary postural adjustments, adapt against accelerating muscle fatigue, and consider volitional actions of the intact upper-body of the user. Model-based development for novel control schemes are proven and sensible approaches to prototype and test the basic operating efficacy of potentially complex and multi-faceted control systems. The major considerations for further innovation of such systems are summarized in this paper prior to describing the evolution of closed-loop FNS control of standing from previous works. Finally, necessary emerging technologies to for implementing FNS feedback control systems for standing are identified. These technological advancements include novel electrodes that more completely and selectively activate paralyzed musculature and implantable sensors and stimulation modules for flexible neuroprosthesis system deployment.
Collapse
|
13
|
Irwin ZT, Schroeder KE, Vu PP, Tat DM, Bullard AJ, Woo SL, Sando IC, Urbanchek MG, Cederna PS, Chestek CA. Chronic recording of hand prosthesis control signals via a regenerative peripheral nerve interface in a rhesus macaque. J Neural Eng 2016; 13:046007. [PMID: 27247270 DOI: 10.1088/1741-2560/13/4/046007] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Loss of even part of the upper limb is a devastating injury. In order to fully restore natural function when lacking sufficient residual musculature, it is necessary to record directly from peripheral nerves. However, current approaches must make trade-offs between signal quality and longevity which limit their clinical potential. To address this issue, we have developed the regenerative peripheral nerve interface (RPNI) and tested its use in non-human primates. APPROACH The RPNI consists of a small, autologous partial muscle graft reinnervated by a transected peripheral nerve branch. After reinnervation, the graft acts as a bioamplifier for descending motor commands in the nerve, enabling long-term recording of high signal-to-noise ratio (SNR), functionally-specific electromyographic (EMG) signals. We implanted nine RPNIs on separate branches of the median and radial nerves in two rhesus macaques who were trained to perform cued finger movements. MAIN RESULTS No adverse events were noted in either monkey, and we recorded normal EMG with high SNR (>8) from the RPNIs for up to 20 months post-implantation. Using RPNI signals recorded during the behavioral task, we were able to classify each monkey's finger movements as flexion, extension, or rest with >96% accuracy. RPNI signals also enabled functional prosthetic control, allowing the monkeys to perform the same behavioral task equally well with either physical finger movements or RPNI-based movement classifications. SIGNIFICANCE The RPNI signal strength, stability, and longevity demonstrated here represents a promising method for controlling advanced prosthetic limbs and fully restoring natural movement.
Collapse
Affiliation(s)
- Z T Irwin
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Implanted neuroprosthesis for restoring arm and hand function in people with high level tetraplegia. Arch Phys Med Rehabil 2014; 95:1201-1211.e1. [PMID: 24561055 DOI: 10.1016/j.apmr.2014.01.028] [Citation(s) in RCA: 76] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2013] [Revised: 01/28/2014] [Accepted: 01/29/2014] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To develop and apply an implanted neuroprosthesis to restore arm and hand function to individuals with high level tetraplegia. DESIGN Case study. SETTING Clinical research laboratory. PARTICIPANTS Individuals with spinal cord injuries (N=2) at or above the C4 motor level. INTERVENTIONS The individuals were each implanted with 2 stimulators (24 stimulation channels and 4 myoelectric recording channels total). Stimulating electrodes were placed in the shoulder and arm, being, to our knowledge, the first long-term application of spiral nerve cuff electrodes to activate a human limb. Myoelectric recording electrodes were placed in the head and neck areas. MAIN OUTCOME MEASURES Successful installation and operation of the neuroprosthesis and electrode performance, range of motion, grasp strength, joint moments, and performance in activities of daily living. RESULTS The neuroprosthesis system was successfully implanted in both individuals. Spiral nerve cuff electrodes were placed around upper extremity nerves and activated the intended muscles. In both individuals, the neuroprosthesis has functioned properly for at least 2.5 years postimplant. Hand, wrist, forearm, elbow, and shoulder movements were achieved. A mobile arm support was needed to support the mass of the arm during functional activities. One individual was able to perform several activities of daily living with some limitations as a result of spasticity. The second individual was able to partially complete 2 activities of daily living. CONCLUSIONS Functional electrical stimulation is a feasible intervention for restoring arm and hand functions to individuals with high tetraplegia. Forces and movements were generated at the hand, wrist, elbow, and shoulder that allowed the performance of activities of daily living, with some limitations requiring the use of a mobile arm support to assist the stimulated shoulder forces.