Jia Y, Li Y, Luosang G, Wang J, Peng G, Pu X, Jiang W, Li W, Zhao Z, Peng Y, Feng Y, Wei J, Xu Y, Liu X, Yi Z, Chen M. Electrocardiogram-based prediction of conduction disturbances after transcatheter aortic valve replacement with convolutional neural network. EUROPEAN HEART JOURNAL. DIGITAL HEALTH 2024; 5:219-228. [PMID: 38774374 PMCID: PMC11104474 DOI: 10.1093/ehjdh/ztae007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 12/21/2023] [Accepted: 01/06/2024] [Indexed: 05/24/2024]
Abstract
Aims Permanent pacemaker implantation and left bundle branch block are common complications after transcatheter aortic valve replacement (TAVR) and are associated with impaired prognosis. This study aimed to develop an artificial intelligence (AI) model for predicting conduction disturbances after TAVR using pre-procedural 12-lead electrocardiogram (ECG) images. Methods and results We collected pre-procedural 12-lead ECGs of patients who underwent TAVR at West China Hospital between March 2016 and March 2022. A hold-out testing set comprising 20% of the sample was randomly selected. We developed an AI model using a convolutional neural network, trained it using five-fold cross-validation and tested it on the hold-out testing cohort. We also developed and validated an enhanced model that included additional clinical features. After applying exclusion criteria, we included 1354 ECGs of 718 patients in the study. The AI model predicted conduction disturbances in the hold-out testing cohort with an area under the curve (AUC) of 0.764, accuracy of 0.743, F1 score of 0.752, sensitivity of 0.876, and specificity of 0.624, based solely on pre-procedural ECG images. The performance was better than the Emory score (AUC = 0.704), as well as the logistic (AUC = 0.574) and XGBoost (AUC = 0.520) models built with previously identified high-risk ECG patterns. After adding clinical features, there was an increase in the overall performance with an AUC of 0.779, accuracy of 0.774, F1 score of 0.776, sensitivity of 0.794, and specificity of 0.752. Conclusion Artificial intelligence-enhanced ECGs may offer better predictive value than traditionally defined high-risk ECG patterns.
Collapse
Affiliation(s)
- Yuheng Jia
- Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China
| | - Yiming Li
- Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China
| | - Gaden Luosang
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, P. R. China
- Department of Information Science and Technology, Tibet University, No.10 Zangda East Road, Lhasa 850000, Tibet, P. R. China
| | - Jianyong Wang
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, P. R. China
| | - Gang Peng
- Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China
| | - Xingzhou Pu
- Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China
| | - Weili Jiang
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, P. R. China
| | - Wenjian Li
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, P. R. China
| | - Zhengang Zhao
- Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China
| | - Yong Peng
- Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China
| | - Yuan Feng
- Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China
| | - Jiafu Wei
- Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China
| | - Yuanning Xu
- Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China
| | - Xingbin Liu
- Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China
| | - Zhang Yi
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, P. R. China
| | - Mao Chen
- Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China
| |
Collapse
|
2
|
Qi Y, Lin X, Pan W, Zhang X, Ding Y, Chen S, Zhang L, Zhou D, Ge J. A prediction model for permanent pacemaker implantation after transcatheter aortic valve replacement. Eur J Med Res 2023; 28:262. [PMID: 37516891 PMCID: PMC10387194 DOI: 10.1186/s40001-023-01237-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 07/18/2023] [Indexed: 07/31/2023] Open
Abstract
BACKGROUND This study aims to develop a post-procedural risk prediction model for permanent pacemaker implantation (PPMI) in patients treated with transcatheter aortic valve replacement (TAVR). METHODS 336 patients undergoing TAVR at a single institution were included for model derivation. For primary analysis, multivariate logistic regression model was used to evaluate predictors and a risk score system was devised based on the prediction model. For secondary analysis, a Cox proportion hazard model was performed to assess characteristics associated with the time from TAVR to PPMI. The model was validated internally via bootstrap and externally using an independent cohort. RESULTS 48 (14.3%) patients in the derivation set had PPMI after TAVR. Prior right bundle branch block (RBBB, OR: 10.46; p < 0.001), pre-procedural aortic valve area (AVA, OR: 1.41; p = 0.004) and post- to pre-procedural AVA ratio (OR: 1.72; p = 0.043) were identified as independent predictors for PPMI. AUC was 0.7 and 0.71 in the derivation and external validation set. Prior RBBB (HR: 5.07; p < 0.001), pre-procedural AVA (HR: 1.33; p = 0.001), post-procedural AVA to prosthetic nominal area ratio (HR: 0.02; p = 0.039) and post- to pre-procedural troponin-T difference (HR: 1.72; p = 0.017) are independently associated with time to PPMI. CONCLUSIONS The post-procedural prediction model achieved high discriminative power and accuracy for PPMI. The risk score system was constructed and validated, providing an accessible tool in clinical setting regarding the Chinese population.
Collapse
Affiliation(s)
- Yiming Qi
- Department of Cardiology, Zhongshan Hospital, Shanghai Institute of Cardiovascular Diseases, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Xiaolei Lin
- School of Data Science, Fudan University, Shanghai, China
| | - Wenzhi Pan
- Department of Cardiology, Zhongshan Hospital, Shanghai Institute of Cardiovascular Diseases, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Xiaochun Zhang
- Department of Cardiology, Zhongshan Hospital, Shanghai Institute of Cardiovascular Diseases, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Yuefan Ding
- School of Data Science, Fudan University, Shanghai, China
| | - Shasha Chen
- Department of Cardiology, Zhongshan Hospital, Shanghai Institute of Cardiovascular Diseases, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Lei Zhang
- Department of Cardiology, Zhongshan Hospital, Shanghai Institute of Cardiovascular Diseases, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Daxin Zhou
- Department of Cardiology, Zhongshan Hospital, Shanghai Institute of Cardiovascular Diseases, Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
- National Clinical Research Center for Interventional Medicine, Shanghai, China.
| | - Junbo Ge
- Department of Cardiology, Zhongshan Hospital, Shanghai Institute of Cardiovascular Diseases, Fudan University, 180 Fenglin Road, Shanghai, 200032, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| |
Collapse
|
3
|
Rivera FB, Cha SW, Aparece JP, Gonzales JST, Salva WFC, Bantayan NRB, Carado GP, Sharma V, Al-Abcha A, Co ML, Collado FMS, Volgman AS. Sex differences in permanent pacemaker implantation after transcatheter aortic valve replacement: a systematic review and meta-analysis. Expert Rev Cardiovasc Ther 2023; 21:631-641. [PMID: 37608465 DOI: 10.1080/14779072.2023.2250719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 08/16/2023] [Accepted: 08/18/2023] [Indexed: 08/24/2023]
Abstract
BACKGROUND There is limited evidence on the effect of sex on permanent pacemaker implantation (PPMI) after transcatheter aortic valve replacement (TAVR). The primary objective of this meta-analysis was to determine the role of sex among patients requiring PPMI post-TAVR. METHODS A literature search was conducted using the SCOPUS, MEDLINE, and CINAHL databases for studies published until October 2022. Eligible studies included published randomized controlled trials (RCTs) and Observational Cohort Studies (OCS) articles that reported PPMI as an outcome of pacemaker status following TAVR. This study was performed per the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Guidelines. Publication bias was estimated using a Funnel plot and Egger's test. Data were pooled using a random-effects model. The primary endpoint was the sex difference in PPMI after TAVR, with odds ratios and 95% confidence intervals (CIs) extracted. RESULTS Data was obtained from 63 studies, and a total of 79,655 patients were included. The cumulative PPMI rate was 15.5% (95% CI, 13.6%-17.7%). The pooled analysis revealed that while there were more females than males undergoing TAVR (51.6%, 95% CI 50.4%-52.8%), males have a 14.5% higher risk for post-TAVR PPMI than females (OR 1.145, 95% CI 1.047-1.253, P < 0.01). CONCLUSIONS Males are more likely to experience PPMI after TAVR than females. Further research needs to be done to better explain these observed differences in outcomes.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Vikram Sharma
- Department of Cardiology, University of Iowa Hospitals and Clinics, Lowa City, IA, USA
| | - Abdullah Al-Abcha
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Michael Lawrenz Co
- Section of Clinical Cardiac Electrophysiology, Thomas Jefferson University, Philadelphia, PA, USA
| | | | | |
Collapse
|
4
|
Gada H, Vora AN, Tang GHL, Mumtaz M, Forrest JK, Laham RJ, Yakubov SJ, Deeb GM, Rammohan C, Huang J, Reardon MJ. Site-Level Variation and Predictors of Permanent Pacemaker Implantation Following TAVR in the Evolut Low-Risk Trial. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2023; 47:48-54. [PMID: 36266154 DOI: 10.1016/j.carrev.2022.10.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 10/10/2022] [Accepted: 10/11/2022] [Indexed: 01/28/2023]
Abstract
We evaluated predictors of permanent pacemaker implantation (PPI) following self-expanding transcatheter aortic valve replacement (TAVR), examined site-to-site variability of PPI rates, and explored the relationship of implantation methods on the need for PPI. Despite the benefits of TAVR compared to surgical aortic valve replacement, increased PPI remains a limitation. A total of 699 patients without baseline PPI were included in the study. Clinical, echocardiographic, and procedural characteristics were compared in patient with and without new PPI. Clinical outcomes were assessed at 30 days and 1 year. Funnel plots were constructed to display site-to- site variability and identify outliers in PPI. Clinical outcomes were similar in patients with and without PPI. Predictors of a new PPI within 7 days included a baseline right bundle branch block (p < 0.001) and not using general anesthesia (p = 0.003). There was substantial site to site variability in the rate of PPI. Patients at sites with a lower PPI rate had shallower implantation depth at the non-coronary (p < 0.001) and the left coronary sinus (p < 0.001), and fewer patients with an implantation depth > 5 mm below the annulus (p = 0.004). In low-risk patients undergoing TAVR with Evolut valves, baseline conduction disorders and implant depth were important predictors of PPI. Implantation method may have contributed to this variability in PPI rates across clinical sites.
Collapse
Affiliation(s)
- Hemal Gada
- Department of Interventional Cardiology, University of Pittsburgh Medical Center Pinnacle, Wormleysburg, PA, United States of America.
| | - Amit N Vora
- Department of Interventional Cardiology, University of Pittsburgh Medical Center Pinnacle, Wormleysburg, PA, United States of America
| | - Gilbert H L Tang
- Department of Cardiovascular Surgery, Mount Sinai Health System, NY, New York, United States of America
| | - Mubashir Mumtaz
- Department of Interventional Cardiology, University of Pittsburgh Medical Center Pinnacle, Wormleysburg, PA, United States of America
| | - John K Forrest
- Department of Internal Medicine (Cardiology), Yale University School of Medicine, New Haven, CT, United States of America
| | - Roger J Laham
- Department of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, United States of America
| | - Steven J Yakubov
- Department of Interventional Cardiology, Riverside Methodist-Ohio Health, Columbus, OH, United States of America
| | - G Michael Deeb
- Department of Cardiac Surgery, University of Michigan Hospitals, Ann Arbor, MI, United States of America
| | - Chad Rammohan
- El Camino Hospital, Department of Interventional Cardiology, Mountain View, CA, United States of America
| | - Jian Huang
- Department of Statistics, Medtronic, Minneapolis, MN, United States of America
| | - Michael J Reardon
- Department of Cardiothoracic Surgery, Houston Methodist DeBakey Heart and Vascular Institute, Houston, TX, United States of America
| |
Collapse
|
5
|
Wang T, Ou A, Xia P, Tian J, Wang H, Cheng Z. Predictors for the risk of permanent pacemaker implantation after transcatheter aortic valve replacement: A systematic review and meta-analysis. J Card Surg 2021; 37:377-405. [PMID: 34775652 DOI: 10.1111/jocs.16129] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 08/22/2021] [Accepted: 09/26/2021] [Indexed: 02/05/2023]
Abstract
BACKGROUND Transcatheter aortic valve replacement (TAVR) is a less invasive treatment than surgery for severe aortic stenosis. However, its use is restricted by the fact that many patients eventually require permanent pacemaker implantation (PPMI). This meta-analysis was performed to identify predictors of post-TAVR PPMI. METHODS The PubMed, Embase, Web of Science, and Cochrane Library databases were systematically searched. Relevant studies that met the inclusion criteria were included in the pooling analysis after quality assessment. RESULTS After pooling 67 studies on post-TAVR PPMI risk in 97,294 patients, balloon-expandable valve use was negatively correlated with PPMI risk compared with self-expandable valve (SEV) use (odds ratio [OR]: 0.44, 95% confidence interval [CI]: 0.37-0.53). Meta-regression analysis revealed that history of coronary artery bypass grafting and higher Society of Thoracic Surgeons (STS) risk score increased the risk of PPMI with SEV utilization. Patients with pre-existing cardiac conduction abnormalities in 28 pooled studies also had a higher risk of PPMI (OR: 2.33, 95% CI: 1.90-2.86). Right bundle branch block (OR: 5.2, 95% CI: 4.37-6.18) and first-degree atrioventricular block (OR: 1.97, 95% CI: 1.38-2.79) also increased PPMI risk. Although the trans-femoral approach was positively correlated with PPMI risk, the trans-apical pathway showed no statistical difference to the trans-femoral pathway. The approach did not increase PPMI risk in patients with STS scores >8. Patient-prosthesis mismatch did not influence post-TAVR PPMI risk (OR: 0.88, 95% CI: 0.67-1.16). We also analyzed implantation depth and found no difference between patients with PPMI after TAVR and those without. CONCLUSIONS SEV selection, pre-existing cardiac conduction abnormality, and trans-femoral pathway selection are positively correlated with PPMI after TAVR. Pre-existing left bundle branch block, patient-prosthesis mismatch, and implantation depth did not affect the risk of PPMI after TAVR.
Collapse
Affiliation(s)
- Tongyu Wang
- Department of Cardiovascular Medicine, The Fourth Affiliated Hospital of China Medical University, Shenyang, Liaoning, China
| | - Aixin Ou
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China
| | - Ping Xia
- Department of Cardiovascular Medicine, The Fourth Affiliated Hospital of China Medical University, Shenyang, Liaoning, China
| | - Jiahu Tian
- Department of Cardiovascular Medicine, The Fourth Affiliated Hospital of China Medical University, Shenyang, Liaoning, China
| | - Hongchang Wang
- Department of Emergency Medicine, The First Affiliated Hospital of Lanzhou Medical University, Lanzhou, China
| | - Zeyi Cheng
- Department of Cardiac Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| |
Collapse
|
6
|
Sammour Y, Krishnaswamy A, Kumar A, Puri R, Tarakji KG, Bazarbashi N, Harb S, Griffin B, Svensson L, Wazni O, Kapadia SR. Incidence, Predictors, and Implications of Permanent Pacemaker Requirement After Transcatheter Aortic Valve Replacement. JACC Cardiovasc Interv 2021; 14:115-134. [PMID: 33478630 DOI: 10.1016/j.jcin.2020.09.063] [Citation(s) in RCA: 132] [Impact Index Per Article: 33.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 08/04/2020] [Accepted: 09/29/2020] [Indexed: 12/29/2022]
Abstract
Transcatheter aortic valve replacement (TAVR) is a safe and feasible alternative to surgery in patients with symptomatic severe aortic stenosis regardless of the surgical risk. Conduction abnormalities requiring permanent pacemaker (PPM) implantation remain a common finding after TAVR due to the close proximity of the atrioventricular conduction system to the aortic root. High-grade atrioventricular block and new onset left bundle branch block (LBBB) are the most commonly reported conduction abnormalities after TAVR. The overall rate of PPM implantation after TAVR varies and is related to pre-procedural and intraprocedural factors. The available literature regarding the impact of conduction abnormalities and PPM requirement on morbidity and mortality is still conflicting. Pre-procedural conduction abnormalities such as right bundle branch block and LBBB have been linked with increased PPM implantation and mortality after TAVR. When screening patients for TAVR, heart teams should be aware of various anatomical and pathophysiological conditions that make patients more susceptible to increased risk of conduction abnormalities and PPM requirement after the procedure. This is particularly important as TAVR has been recently approved for patients with low surgical risk. The purpose of this review is to discuss the incidence, predictors, impact, and management of the various conduction abnormalities requiring PPM implantation in patients undergoing TAVR.
Collapse
Affiliation(s)
- Yasser Sammour
- Department of Internal Medicine, University of Missouri-Kansas City School of Medicine, Kansas City, Missouri, USA; Heart and Vascular Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA
| | - Amar Krishnaswamy
- Heart and Vascular Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA
| | - Arnav Kumar
- Andreas Gruentzig Cardiovascular Center, Division of Cardiology, Emory University School of Medicine, Atlanta, Georgia, USA
| | - Rishi Puri
- Heart and Vascular Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA
| | - Khaldoun G Tarakji
- Heart and Vascular Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA
| | - Najdat Bazarbashi
- Heart and Vascular Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA; Department of Internal Medicine, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Serge Harb
- Heart and Vascular Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA
| | - Brian Griffin
- Heart and Vascular Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA
| | - Lars Svensson
- Heart and Vascular Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA
| | - Oussama Wazni
- Heart and Vascular Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA
| | - Samir R Kapadia
- Heart and Vascular Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA.
| |
Collapse
|
7
|
Impact of Bundle Branch Block on Permanent Pacemaker Implantation after Transcatheter Aortic Valve Implantation: A Meta-Analysis. J Clin Med 2021; 10:jcm10122719. [PMID: 34205478 PMCID: PMC8235153 DOI: 10.3390/jcm10122719] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 06/10/2021] [Accepted: 06/15/2021] [Indexed: 12/30/2022] Open
Abstract
Data regarding the impact of infra-Hisian conduction disturbances leading to permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) remain limited. The aim of this study was to determine the impact of right and/or left bundle branch block (RBBB/LBBB) on post-TAVI PPI. We performed a systematic literature review to identify studies reporting on RBBB and/or LBBB status and post-TAVI PPI. Study design, patient characteristics, and the presence of branch block were analyzed. Odds ratios (ORs) with 95% CI were extracted. The final analysis included 36 studies, reporting about 55,851 patients. Data on LBBB were extracted from 33 studies. Among 51,026 patients included, 5503 showed pre-implant LBBB (11.9% (10.4%–13.8%)). The influence of LBBB on post-TAVI PPI was not significant OR 1.1474 (0.9025; 1.4588), p = 0.2618. Data on RBBB were extracted from 28 studies. Among 46,663 patients included, 31,603 showed pre-implant RBBB (9.2% (7.3%–11.6%)). The influence of RBBB on post-TAVI PPI was significant OR 4.8581 (4.1571; 5.6775), p < 0.0001. From this meta-analysis, the presence of RBBB increased the risk for post-TAVI PPI, independent of age or LVEF, while this finding was not confirmed for patients experimenting with LBBB. This result emphasizes the need for pre-operative evaluation strategies in patient selection for TAVI.
Collapse
|
8
|
Hwang YM, Kim J, Nam GB, Choi KJ, Park DW, Kang DY, Park SJ, Park SY. Pacemaker dependency after transcatheter aortic valve replacement compared to surgical aortic valve replacement. Medicine (Baltimore) 2021; 100:e26123. [PMID: 34087862 PMCID: PMC8183801 DOI: 10.1097/md.0000000000026123] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Accepted: 05/10/2021] [Indexed: 01/04/2023] Open
Abstract
Transcatheter aortic valve replacement (TAVR) is a standard treatment indicated for severe aortic stenosis in high-risk patients. The objective of this study was to evaluate the incidence of pacemaker dependency after permanent pacemaker implantation (PPI) following TAVR or surgical aortic valve replacement (SAVR) and the risk of mortality at a tertiary center in Korea.In this retrospective study conducted at a single tertiary center, clinical outcomes related to pacemaker dependency were evaluated for patients implanted with pacemakers after TAVR from January 2012 to November 2018 and post-SAVR from January 2005 to May 2015. Investigators reviewed patients' electrocardiograms and baseline rhythms as well as conduction abnormalities. Pacemaker dependency was defined as a ventricular pacing rate > 90% with an intrinsic rate of <40 bpm during interrogation.Of 511 patients who underwent TAVR for severe AS, 37(7.3%) underwent PPI after a median duration of 6 (3-7) days, whereas pacemakers were implanted after a median interval of 13 (8-28) days post-SAVR in 10 of 663 patients (P < .001). Pacemaker dependency was observed in 36 (97.3%) patients during 7 days immediately post-TAVR and in 25 (64.9%) patients between 8 and 180 days post-TAVR. Pacemaker dependency occurred after 180 days in 17 (50%) patients with TAVR and in 4 (44.4%) patients with SAVR. Twelve (41.4%) patients were pacemaker-dependent after 365 days post-TAVR.Pacemaker dependency did not differ at 6 months after TAVR vs SAVR. In patients undergoing post-TAVR PPI, 58.6% were not pacemaker-dependent at 1 year after the TAVR procedure.
Collapse
Affiliation(s)
- You Mi Hwang
- Department of Cardiology, St. Vincent's Hospital, The Catholic University of Korea
| | | | | | | | | | | | | | - Seo Young Park
- Department of Clinical Epidemiology and Biostatistics, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
9
|
Ravaux JM, Di Mauro M, Vernooy K, Van't Hof AW, Veenstra L, Kats S, Maessen JG, Lorusso R. Do Women Require Less Permanent Pacemaker After Transcatheter Aortic Valve Implantation? A Meta-Analysis and Meta-Regression. J Am Heart Assoc 2021; 10:e019429. [PMID: 33779244 PMCID: PMC8174375 DOI: 10.1161/jaha.120.019429] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Background Limited clinical evidence and literature are available about the potential impact of sex on permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI). The aim of this work was to evaluate the relationship between sexes and atrioventricular conduction disturbances requiring PPI after TAVI. Methods and Results Data were obtained from 46 studies from PubMed reporting information about the impact of patient sex on PPI after TAVI. Total proportions with 95% Cls were reported. Funnel plot and Egger test were used for estimation of publication bias. The primary end point was 30‐day or in‐hospital PPI after TAVI, with odds ratios and 95% CIs extracted. A total of 70 313 patients were included, with a cumulative proportion of 51.5% of women (35 691 patients; 95% CI, 50.2–52.7). The proportion of women undergoing TAVI dropped significantly over time (P<0.0001). The cumulative PPI rate was 15.6% (95% CI, 13.3–18.3). The cumulative rate of PPI in women was 14.9% (95% CI, 12.6–17.6), lower than in men (16.6%; 95% CI, 14.2–19.4). The risk for post‐TAVI PPI was lower in women (odds ratio, 0.90; 95% CI, 0.84–0.96 [P=0.0022]). By meta‐regression analysis, age (P=0.874) and ventricular function (P=0.302) were not significantly associated with PPI among the sexes. Balloon‐expandable TAVI significantly decrease the advantage of women for PPI, approaching the same rate as in men (P=0.0061). Conclusions Female sex is associated with a reduced rate of PPI after TAVI, without influence of age or ventricular function. Balloon‐expandable devices attenuate this advantage in favor of women. Additional investigations are warranted to elucidate sex‐based differences in developing conduction disturbances after TAVI.
Collapse
Affiliation(s)
- Justine M Ravaux
- Department of Cardio-Thoracic Surgery Heart and Vascular Centre Maastricht University Medical Centre (MUMC) Maastricht The Netherlands
| | - Michele Di Mauro
- Department of Cardio-Thoracic Surgery Heart and Vascular Centre Maastricht University Medical Centre (MUMC) Maastricht The Netherlands.,Cardiovascular Research Institute Maastricht (CARIM)Maastricht University Medical Center Maastricht The Netherlands
| | - Kevin Vernooy
- Cardiovascular Research Institute Maastricht (CARIM)Maastricht University Medical Center Maastricht The Netherlands.,Department of Cardiology Maastricht University Medical Centre (MUMC) Maastricht The Netherlands.,Department of cardiology Radboud University Medical Center (Radboudumc) Nijmegen The Netherlands
| | - Arnoud W Van't Hof
- Cardiovascular Research Institute Maastricht (CARIM)Maastricht University Medical Center Maastricht The Netherlands.,Department of Cardiology Maastricht University Medical Centre (MUMC) Maastricht The Netherlands
| | - Leo Veenstra
- Cardiovascular Research Institute Maastricht (CARIM)Maastricht University Medical Center Maastricht The Netherlands
| | - Suzanne Kats
- Department of Cardio-Thoracic Surgery Heart and Vascular Centre Maastricht University Medical Centre (MUMC) Maastricht The Netherlands
| | - Jos G Maessen
- Department of Cardio-Thoracic Surgery Heart and Vascular Centre Maastricht University Medical Centre (MUMC) Maastricht The Netherlands.,Department of Cardiology Maastricht University Medical Centre (MUMC) Maastricht The Netherlands
| | - Roberto Lorusso
- Department of Cardio-Thoracic Surgery Heart and Vascular Centre Maastricht University Medical Centre (MUMC) Maastricht The Netherlands.,Cardiovascular Research Institute Maastricht (CARIM)Maastricht University Medical Center Maastricht The Netherlands
| |
Collapse
|
10
|
Ramanathan PK, Nazir S, Elzanaty AM, Nesheiwat Z, Mahmood M, Rachwal W, Riordan C, Letcher J, Yenrick K, Boonie E, Moront MG, Redfern RE, Crescenzo D. Novel Method for Implantation of Balloon Expandable Transcatheter Aortic Valve Replacement to Reduce Pacemaker Rate—Line of Lucency Method. STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM 2020. [DOI: 10.1080/24748706.2020.1813355] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
| | - Salik Nazir
- ProMedica Heart Institute, ProMedica Toledo Hospital, Toledo, Ohio, USA
- Department of Cardiovascular Medicine, University of Toledo, Toledo, Ohio, USA
| | - Ahmed M. Elzanaty
- ProMedica Heart Institute, ProMedica Toledo Hospital, Toledo, Ohio, USA
- Department of Internal Medicine, University of Toledo, Toledo, Ohio, USA
| | - Zeid Nesheiwat
- ProMedica Heart Institute, ProMedica Toledo Hospital, Toledo, Ohio, USA
- Department of Internal Medicine, University of Toledo, Toledo, Ohio, USA
| | - Muhammad Mahmood
- ProMedica Heart Institute, ProMedica Toledo Hospital, Toledo, Ohio, USA
- Department of Internal Medicine, University of Toledo, Toledo, Ohio, USA
| | - William Rachwal
- ProMedica Heart Institute, ProMedica Toledo Hospital, Toledo, Ohio, USA
| | | | - John Letcher
- ProMedica Heart Institute, ProMedica Toledo Hospital, Toledo, Ohio, USA
| | - Kellie Yenrick
- ProMedica Heart Institute, ProMedica Toledo Hospital, Toledo, Ohio, USA
| | - Erica Boonie
- ProMedica Heart Institute, ProMedica Toledo Hospital, Toledo, Ohio, USA
| | - Michael G. Moront
- ProMedica Heart Institute, ProMedica Toledo Hospital, Toledo, Ohio, USA
| | | | - Donald Crescenzo
- ProMedica Heart Institute, ProMedica Toledo Hospital, Toledo, Ohio, USA
| |
Collapse
|