1
|
Sakamoto S, Shimizu S, Uchida H, Fukuda A, Kasahara M. Portal vein pressure and flow modulation in pediatric liver transplantation. Pediatr Transplant 2023; 27:e14563. [PMID: 37470148 DOI: 10.1111/petr.14563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Accepted: 06/23/2023] [Indexed: 07/21/2023]
Abstract
Liver transplantation (LT) has been indicated for smaller and more clinically severe patients in recent years. Small biliary atresia (BA) patients often show portal hypoplasia and sclerotic portal vein (PV), which may make PV reconstruction more difficult during the operation. Among PV complications, intraoperative PV thrombosis can be considered a disaster, and it is important to prevent this catastrophic event by the precise assessment of the PV structure and PVF using radiological imaging before and during LT. However, there are no objective parameters to indicate whether sufficient PVF can be obtained. PV pressure (PVP) and PV flow (PVF) have mainly been studied in adult living donor LT, for the purpose of preventing small-for-size syndrome, and PVP has been considered an objective parameter of graft inflow modulation (GIM). In the setting of pediatric LT, GIM is mainly performed to prevent hypoperfusion, and it must be performed before graft implantation. GIM to maximize the PVF of pediatric patients with potentially low PVF in LT consists of the interruption of collateral vessels, the assessment of the usability of the native PV, and technical modifications in PV reconstruction. Reliable objective parameters that represent sufficient PVF before graft implantation are desired. Our recent study proposed that a PVP of ≥25 mmHg before graft implantation can be considered an objective parameter to obtain sufficient PVF (cutoff value: 50 mL/min/100 g of graft weight). Further investigation is needed to determine the best strategy for successful PV reconstruction in pediatric LT.
Collapse
Affiliation(s)
- Seisuke Sakamoto
- Organ Transplantation Center, National Center for Child Health and Development, Tokyo, Japan
| | - Seiichi Shimizu
- Organ Transplantation Center, National Center for Child Health and Development, Tokyo, Japan
| | - Hajime Uchida
- Organ Transplantation Center, National Center for Child Health and Development, Tokyo, Japan
| | - Akinari Fukuda
- Organ Transplantation Center, National Center for Child Health and Development, Tokyo, Japan
| | - Mureo Kasahara
- Organ Transplantation Center, National Center for Child Health and Development, Tokyo, Japan
| |
Collapse
|
2
|
Zhang C, Qin X, Zhou W, He S, Liu A, Zhang Y, Dai Z, Yin J. Prediction of Left Double-Lumen Tube Size by Measurement of Cricoid Cartilage Transverse Diameter by Ultrasound and CT Multi-Planar Reconstruction. Front Med (Lausanne) 2021; 8:657612. [PMID: 34222278 PMCID: PMC8242158 DOI: 10.3389/fmed.2021.657612] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Accepted: 05/24/2021] [Indexed: 11/13/2022] Open
Abstract
Background: Currently, there is no uniform standard for selecting the left double lumen tubes (LDLT). Advantages, such as safety and convenience of the ultrasonic technology, and measurement accuracy, make it more widely applied in the clinical anesthesia, and computed tomography (CT) multi-planar reconstruction (MPR) technology will certainly provide a more accurate measurement. For better application for thoracic surgery choice LDLT, relieving the injury to patients, and reducing the complications, this study will compare the two approaches. Methods: The first part, 120 cases of patients were selected according to the height and gender; recording the patient's optimum LDLT and measurement the transverse diameter of the cricoid cartilage (TD-C) by ultrasound and CT MPR, and then obtained the TD-C range measurement by ultrasound and CT MPR corresponding to different types of LDLT. The second part, total of 102 patients were divided into the ultrasound group and the CT MPR group. In the ultrasound group, TD-C was measured by ultrasound, the corresponding size for intubation was selected based on the conclusions derived from the first part. In the CT MPR group, TD-C was measured by CT MPR, the corresponding size of LDLT based on the conclusions derived from the first part. Results: In the first part, 120 patients were no significant difference in the basic characteristics (P > 0.05). The accuracy of selecting the LDLT by conventional experience, namely height and gender was 58.3%. Ultrasonic measurement TD-C range was as follows: 32 Fr <15.88, 35 Fr: 15.88-16.80, 37 Fr: 16.75-17.81, and 39 Fr > 17.80. CT MPR measurement TD-C range was as follows: 32 Fr <15.74, 35 Fr: 15.74-16.65, 37 Fr: 16.56-17.68, and 39 Fr > 17.65. In the second part, there was no significant difference in the basic characteristics between the two groups (P > 0.05). The accuracy of intubation in the ultrasound group was 90.2% and the corresponding in the CT MPR group was 94.1% (P > 0.05). Conclusions: The accuracy of selecting the LDLT based on TD-C is significantly higher than conventional experience; it can significantly reduce the post-operative complications and there was no statistical significance in the accuracy of LDLT selected for TD-C measurement by ultrasound vs. CT, and both of them could be safely used for the evaluation before intubation under anesthesia in thoracic surgery.
Collapse
Affiliation(s)
- Chengchao Zhang
- Department of Anesthesiology, First Affiliated Hospital, School of Medicine, Shihezi University, Shihezi, China
| | - Xinlei Qin
- Department of Anesthesiology, First Affiliated Hospital, School of Medicine, Shihezi University, Shihezi, China
| | - Wenyi Zhou
- Department of Anesthesiology, First Affiliated Hospital, School of Medicine, Shihezi University, Shihezi, China
| | - Shuaijie He
- Department of Anesthesiology, First Affiliated Hospital, School of Medicine, Shihezi University, Shihezi, China
| | - Ao Liu
- Department of Anesthesiology, First Affiliated Hospital, School of Medicine, Shihezi University, Shihezi, China
| | - Yu Zhang
- Department of Anesthesiology, First Affiliated Hospital, School of Medicine, Shihezi University, Shihezi, China
| | - Zhigang Dai
- Department of Anesthesiology, First Affiliated Hospital, School of Medicine, Shihezi University, Shihezi, China
| | - Jiangwen Yin
- Department of Anesthesiology, First Affiliated Hospital, School of Medicine, Shihezi University, Shihezi, China
| |
Collapse
|
3
|
Herrmann J, Tozakidou M, Busch J, Herden U, Fischer L, Groth M, Petersen KU, Helmke K. Persistence of post-operative color Doppler abnormalities is linked to reduced graft survival in pediatric patients after liver transplantation. Pediatr Transplant 2019; 23:e13593. [PMID: 31587463 DOI: 10.1111/petr.13593] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2019] [Revised: 09/02/2019] [Accepted: 09/05/2019] [Indexed: 01/04/2023]
Abstract
Color Doppler US is a readily available imaging modality for the evaluation of liver transplants. The aim of our study was to evaluate the temporal course of color Doppler US findings in children after LTX and to investigate the effect of resolving and persisting abnormalities during follow-up on long-term outcome. All children who underwent LTX during January 2000 until December 2003 (155 LTX in 137 patients, 75 male and 62 female; mean age at LTX 4.1 ± 4.8 years; range, 0.1-16.3 years) were retrospectively evaluated. Following a predefined ultrasound protocol with prospective documentation, intraoperative, post-operative, and follow-up examinations were evaluated for color Doppler abnormalities. The time of occurrence and temporal course of the findings were recorded. Graft survival rates and graft survival times were compared. Abnormal color Doppler US examinations were noted in 98 of 155 grafts during the entire observational period (63.2%). In 57 of 98 grafts (58.2%), abnormalities were limited to the perioperative period (<30 days after LTX). Survival of grafts with transient perioperative abnormalities was similar to transplantations with regular color Doppler US examinations (graft survival rates, 80.7% vs 84.2%, P = .622; mean graft survival time, 2596.92 vs 2511.40 days, P = .67). Grafts with persisting color Doppler US abnormalities in the follow-up period (>30 days after LTX; 37/98 LTX, 37.8%) showed reduced survival compared with regular courses (graft survival rate 62.2% vs 80.7%, P = .047), indicating underlying organ-specific alterations. Standardized longitudinal evaluation during the perioperative and the follow-up period can enhance the prognostic capabilities of color Doppler US in children following LTX.
Collapse
Affiliation(s)
- Jochen Herrmann
- Department of Pediatric Radiology, Diagnostic and Interventional Radiology and Nuclear Medicine, University Clinic Hamburg-Eppendorf, Hamburg, Germany
| | - Magdalini Tozakidou
- Department of Pediatric Radiology, Diagnostic and Interventional Radiology and Nuclear Medicine, University Clinic Hamburg-Eppendorf, Hamburg, Germany
| | - Jasmin Busch
- Department of Pediatric Radiology, Diagnostic and Interventional Radiology and Nuclear Medicine, University Clinic Hamburg-Eppendorf, Hamburg, Germany
| | - Uta Herden
- Department of Hepatobiliary Surgery, University Clinic Hamburg-Eppendorf, Hamburg, Germany
| | - Lutz Fischer
- Department of Hepatobiliary Surgery, University Clinic Hamburg-Eppendorf, Hamburg, Germany
| | - Michael Groth
- Department of Pediatric Radiology, Diagnostic and Interventional Radiology and Nuclear Medicine, University Clinic Hamburg-Eppendorf, Hamburg, Germany
| | - Kay U Petersen
- Department of Psychiatry and Psychotherapy, University Hospital Tübingen, Tübingen, Germany
| | - Knut Helmke
- Department of Pediatric Radiology, Diagnostic and Interventional Radiology and Nuclear Medicine, University Clinic Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|