1
|
Karahan GE, Haasnoot GW, Voogt-Bakker K, Claas FHJ, Roelen D, Heidt S. A modeling approach for mean fluorescence intensity value harmonization and cutoff prediction for luminex single antigen bead assays of two different vendors. HLA 2023; 102:557-569. [PMID: 37130801 DOI: 10.1111/tan.15082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/28/2023] [Accepted: 04/18/2023] [Indexed: 05/04/2023]
Abstract
Luminex single antigen bead (SAB) kits from One Lambda (OL) and Lifecodes (LC) are widely used for HLA antibody detection but have substantial differences in design and assay protocol resulting in different mean fluorescence intensity (MFI) values. Here, we present a non-linear modeling approach to accurately convert MFI values between two vendors and to establish user-independent MFI cutoffs when analyzing big datasets. HLA antibody data from a total of 47 EDTA-treated sera tested using both OL and LC SAB kits were analyzed. MFI comparisons were made for the common 84 HLA class I and 63 class II beads. In the exploration set (n = 24), a non-linear hyperbola model on raw MFI corrected by locus-specific highest self MFI subtraction yielded the highest correlation (class I r2 : 0.946, class II r2 : 0.898). Performance of the model was verified in an independent validation set (n = 12) (class I r2 : 0.952, class II r2 : 0.911). Furthermore, in an independent cohort of post-transplant serum samples (n = 11) using the vendor-specific MFI cutoffs dictated by the current model, we found 94% accuracy in bead-specific reactivity assignments by the two vendors. We recommend using the non-linear hyperbola modeling approach with self HLA correction and locus-specific analyzes to harmonize MFI values between two vendors in particular research datasets. As there are considerable variations between the two assays, using MFI conversion for individual patient samples is not recommended.
Collapse
Affiliation(s)
- Gonca E Karahan
- Department of Immunology, Leiden University Medical Center, Leiden, The Netherlands
| | - Geert W Haasnoot
- Department of Immunology, Leiden University Medical Center, Leiden, The Netherlands
| | - Kim Voogt-Bakker
- Department of Immunology, Leiden University Medical Center, Leiden, The Netherlands
| | - Frans H J Claas
- Department of Immunology, Leiden University Medical Center, Leiden, The Netherlands
| | - Dave Roelen
- Department of Immunology, Leiden University Medical Center, Leiden, The Netherlands
| | - Sebastiaan Heidt
- Department of Immunology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
2
|
Halloran PF, Madill-Thomsen K, Aliabadi-Zuckermann AZ, Cadeiras M, Crespo-Leiro MG, Depasquale EC, Deng M, Gökler J, Kim DH, Kobashigawa J, Macdonald P, Potena L, Shah K, Stehlik J, Zuckermann A. Many heart transplant biopsies currently diagnosed as no rejection have mild molecular antibody-mediated rejection-related changes. J Heart Lung Transplant 2021; 41:334-344. [PMID: 34548198 DOI: 10.1016/j.healun.2021.08.004] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Revised: 07/12/2021] [Accepted: 08/18/2021] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND The Molecular Microscope (MMDx) system classifies heart transplant endomyocardial biopsies as No-rejection (NR), Early-injury, T cell-mediated (TCMR), antibody-mediated (ABMR), mixed, and possible rejection (possible TCMR, possible ABMR). Rejection-like gene expression patterns in NR biopsies have not been described. We extended the MMDx methodology, using a larger data set, to define a new "Minor" category characterized by low-level inflammation in non-rejecting biopsies. METHODS Using MMDx criteria from a previous study, molecular rejection was assessed in 1,320 biopsies (645 patients) using microarray expression of rejection-associated transcripts (RATs). Of these biopsies, 819 were NR. A new archetypal analysis model in the 1,320 data set split the NRs into NR-Normal (N = 462) and NR-Minor (N = 359). RESULTS Compared to NR-Normal, NR-Minor were more often histologic TCMR1R, with a higher prevalence of donor-specific antibody (DSA). DSA positivity increased in a gradient: NR-Normal 24%; NR-Minor 34%; possible ABMR 42%; ABMR 66%. The top 20 transcripts distinguishing NR-Minor from NR-Normal were all ABMR-related and/or IFNG-inducible, and also exhibited a gradient of increasing expression from NR-Normal through ABMR. In random forest analysis, TCMR and Early-injury were associated with reduced LVEF and increased graft loss, but NR-Minor and ABMR scores were not. Surprisingly, hearts with MMDx ABMR showed comparatively little graft loss. CONCLUSIONS Many heart transplants currently diagnosed as NR by histologic or molecular assessment have minor increases in ABMR-related and IFNG-inducible transcripts, associated with DSA positivity and mild histologic inflammation. These results suggest that low-level ABMR-related molecular stress may be operating in many more hearts than previously estimated. (ClinicalTrials.gov #NCT02670408).
Collapse
Affiliation(s)
| | | | | | | | | | | | - Mario Deng
- Ronald Reagan UCLA Medical Center, Los Angeles, California
| | | | - Daniel H Kim
- University of Alberta, Edmonton, Alberta, Canada
| | | | - Peter Macdonald
- The Victor Chang Cardiac Research Institute, Sydney, Australia
| | | | - Keyur Shah
- Virginia Commonwealth University, Richmond, Virginia
| | | | | |
Collapse
|
3
|
Heidt S, Haasnoot GW, van der Linden-van Oevelen MJH, Claas FHJ. Highly Sensitized Patients Are Well Served by Receiving a Compatible Organ Offer Based on Acceptable Mismatches. Front Immunol 2021; 12:687254. [PMID: 34248971 PMCID: PMC8267476 DOI: 10.3389/fimmu.2021.687254] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Accepted: 06/14/2021] [Indexed: 01/10/2023] Open
Abstract
Highly sensitized kidney patients accrue on the transplant waiting list due to their broad immunization against non-self Human Leucocyte Antigens (HLA). Although challenging, the best option for highly sensitized patients is transplantation with a crossmatch negative donor without any additional therapeutic intervention. The Eurotransplant Acceptable Mismatch (AM) program was initiated more than 30 years ago with the intention to increase the chance for highly sensitized patients to be transplanted with such a compatible donor. The AM program allows for enhanced transplantation to this difficult to transplant patient group by allocating deceased donor kidneys on the basis of a match with the recipient’s own HLA antigens in combination with predefined acceptable antigens. Acceptable antigens are those HLA antigens towards which the patients has never formed antibodies, as determined by extensive laboratory testing. By using this extended HLA phenotype for allocation and giving priority whenever a compatible donor organ becomes available, organ offers are made for roughly 80% of patients in this program. Up till now, more than 1700 highly sensitized patients have been transplanted through the AM program. Recent studies have shown that the concept of acceptable mismatches being truly immunologically acceptable holds true for both rejection rates and long-term graft survival. Patients that were transplanted through the AM program had a similar rejection incidence and long-term graft survival rates identical to non-sensitized patients transplanted through regular allocation. However, a subset of patients included in the AM program does not receive an organ offer within a reasonable time frame. As these are often patients with a rare HLA phenotype in comparison to the Eurotransplant donor population, extension of the donor pool for these specific patients through further European collaboration would significantly increase their chances of being transplanted. For those patients that will not benefit from such strategy, desensitization is the ultimate solution.
Collapse
Affiliation(s)
- Sebastiaan Heidt
- Eurotransplant Reference Laboratory, Leiden University Medical Center, Leiden, Netherlands
| | - Geert W Haasnoot
- Eurotransplant Reference Laboratory, Leiden University Medical Center, Leiden, Netherlands
| | | | - Frans H J Claas
- Eurotransplant Reference Laboratory, Leiden University Medical Center, Leiden, Netherlands
| |
Collapse
|
4
|
Mumford L, Fuggle SV, Martorell J, Slavcev A, Iniotaki A, Haasnoot GW, Heidt S, Claas FHJ. A Europe wide acceptable mismatch program will enable transplantation of long waiting highly sensitised patients with a compatible donor. Transpl Immunol 2020; 64:101354. [PMID: 33276060 DOI: 10.1016/j.trim.2020.101354] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 11/20/2020] [Indexed: 12/25/2022]
Abstract
Immunisation against Human Leucocyte Antigens (HLA) can be caused by pregnancy, blood transfusion, or organ transplants. The HLA antibody status of a given patient significantly influences their access and waiting time to transplant. For some highly sensitised patients (HSP) there is hardly any suitable donor available in the deceased donor pool of their allocation organisation and therefore they wait a very long time before being offered a kidney for transplant. Especially patients with rare HLA phenotypes in relation to the actual donor pool are waiting extremely long. As HLA phenotypes are different in the various European populations, we hypothesized that extension of the donor pool outside the respective allocation system will increase the chance of receiving a compatible transplant for this subgroup of highly sensitised patients. One of the objectives of the EUROSTAM project, (a Europe-wide Strategy to enhance Transplantation of highly sensitised patients on the basis of Acceptable HLA Mismatches) was to develop a tool to compare the chance of transplanting HSP in different European populations with donor organs from within and outside their own donor pool. Information on the HLA type and ABO blood group of the actual donor population, as well as the acceptable mismatches of long waiting HSP were obtained from the EUROSTAM partner organizations i.e. Eurotransplant (ET), UK National Health Service Blood and Transplant (NHSBT), Barcelona, Prague and Athens. Results from simulations using the newly developed tool shows that 195 (27%) of the 724 long waiting highly sensitised patients registered at each partner organisation have increased chances of transplant in a different European donor pool. This makes a strong case for sharing kidneys between European countries for selected difficult to transplant patients.
Collapse
Affiliation(s)
- Lisa Mumford
- Organ Donation and Transplantation, NHS Blood and Transplant, Bristol, UK
| | - Susan V Fuggle
- Organ Donation and Transplantation, NHS Blood and Transplant, Bristol, UK; Oxford Transplant Centre, Nuffield Department of Surgical Sciences, University of Oxford, UK
| | | | - Antonij Slavcev
- Dept. Immunogenetics, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Aliki Iniotaki
- National Tissue Typing Center, General Hospital of Athens "G. Gennimatas", Athens, Greece
| | - Geert W Haasnoot
- Eurotransplant Reference Laboratory, Leiden University Medical Centre, Leiden, the Netherlands
| | - Sebastiaan Heidt
- Eurotransplant Reference Laboratory, Leiden University Medical Centre, Leiden, the Netherlands
| | - Frans H J Claas
- Eurotransplant Reference Laboratory, Leiden University Medical Centre, Leiden, the Netherlands.
| |
Collapse
|
5
|
Chen M, Zoet Y, Roelen D, Martorell J, Middleton D, Slavcev A, Iniotaki A, Claas F, Fuggle S. Towards uniformity in the definition of acceptable mismatches for highly sensitized patients. HLA 2019; 94:147-153. [PMID: 31177642 PMCID: PMC6771471 DOI: 10.1111/tan.13607] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Revised: 05/16/2019] [Accepted: 06/05/2019] [Indexed: 12/04/2022]
Abstract
The Eurotransplant (The Eurotransplant International Foundation) acceptable mismatch programme has been shown to be a successful tool to enhance transplantation of highly sensitized patients(HSPs). However, patients with rare HLA phenotypes in relation to the Eurotransplant donor population remain on the waiting list. EUROSTAM is an European Union funded project to explore the feasibility of a Europe‐wide acceptable mismatch programme enabling transplantation of HSPs with rare HLA phenotypes within their own organ exchange organization. The present study, which forms part of the EUROSTAM project, assesses the differences in the practices of the laboratories in different countries with respect to their HLA antibody profiling and risk adverseness. In the serum exchange exercises of 18 samples, a high level of variability has been shown in both assays and interpretation of results. In the data exchange exercise when all participants were given the same Luminex raw data for analysis, a high degree of consensus was reached where the median fluorescent intensity values of beads were <500 and >2000 for standard single antigen bead assays, or <500 and >5000 for assignment of acceptable mismatches. The risk adverseness analysis has showed distinct patterns of attitudes towards the perceived risks based on HLA antibody assay results, most probably influenced by the local protocols of the clinical transplant programme of each laboratory. In order to ensure fairness and maintain consistencies of organ exchange among partner transplant centres, a centralized facility will be instrumental for a uniform definition of acceptable mismatches.
Collapse
Affiliation(s)
- Mian Chen
- Oxford Transplant Centre, Nuffield Department of Surgical Sciences, Oxford University Hospitals, Churchill Hospital, Oxford, UK
| | - Yvonne Zoet
- Eurotransplant Reference Laboratory, Department of Immunohematology and Blood Transfusion, Leiden University Medical Center, Leiden, the Netherlands
| | - Dave Roelen
- Department of Immunohematology and Blood transfusion, Leiden University Medical Center, Leiden, the Netherlands
| | | | - Derek Middleton
- Transplant Immunology Laboratory, Royal Liverpool and Broadgreen University Hospital, Liverpool, UK.,Institute of Infection and Global Health, University of Liverpool, Liverpool, UK
| | - Antonij Slavcev
- Department of Immunogenetics, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Aliki Iniotaki
- National Tissue Typing Center, General Hospital of Athens "G. Gennimatas", Athens, Greece
| | - Frans Claas
- Eurotransplant Reference Laboratory, Department of Immunohematology and Blood Transfusion, Leiden University Medical Center, Leiden, the Netherlands.,Department of Immunohematology and Blood transfusion, Leiden University Medical Center, Leiden, the Netherlands
| | - Susan Fuggle
- Oxford Transplant Centre, Nuffield Department of Surgical Sciences, Oxford University Hospitals, Churchill Hospital, Oxford, UK.,Organ Donation and Transplantation, NHS Blood and Transplant, Bristol, UK
| |
Collapse
|