1
|
Wu X, Yang L, Li Z, Yin H, Chen W, Zhang C. Clinical Efficacy of Ultrasound-guided High-intensity Focused Ultrasound Ablation for Treating Breast Fibroadenoma of Different Sizes: A Retrospective Study. Gynecol Minim Invasive Ther 2025; 14:72-80. [PMID: 40143974 PMCID: PMC11936401 DOI: 10.4103/gmit.gmit-d-24-00035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2024] [Revised: 11/21/2024] [Accepted: 12/03/2024] [Indexed: 03/28/2025] Open
Abstract
Objectives The aim of this study was to assess the clinical outcomes of ultrasound (US)-guided high-intensity focused ultrasound (HIFU) in patients with breast fibroadenoma (FA) of different sizes. Materials and Methods A total of 88 patients with 245 lesions diagnosed with FA by core needle biopsy from January 2021 to November 2023 were included in this study. US-guided HIFU was performed under local anesthesia. Baseline and treatment characteristics were recorded and analyzed. FAs were divided into three groups according to the longest diameter for further analysis. After the treatment, follow-up with volume evaluation and physical examination was performed at 3, 6, and 12 months. Results There were 56 FAs ≤10 mm (group 1), 144 FAs with a diameter of 10-20 mm (Group 2), and 45 FAs of 20-30 mm (Group 3). The sonication time of the three groups was 22.5 s, 45.0 s, and 83.0 s (P < 0.05). Based on contrast-enhanced ultrasound evaluation, the median nonperfused volume ratio of the three groups was 74.1%, 87.6%, and 79.2% (P > 0.05), respectively. The volume reduction rates (VRR) of the three groups were 47.3%, 77.0%, and 82.0% at 12 months after HIFU, showing statistical differences. All patients were tolerated well and there were no adverse events after HIFU. Conclusion The current evidence indicated HIFU was effective and safe in treating breast FA of different sizes, and the VRR of FA >1 cm at 12 months post-HIFU was greater than that of FA <1 cm.
Collapse
Affiliation(s)
- Xiuying Wu
- State Key Laboratory of Ultrasound in Medicine and Engineering, Chongqing Medical University, Chongqing, China
| | - Lei Yang
- Department of Breast Surgery, Suining Central Hospital, Suining, China
| | - Zi Li
- State Key Laboratory of Ultrasound in Medicine and Engineering, Chongqing Medical University, Chongqing, China
- Department of Radiology, the First People’s Hospital of Suining, Suining, China
| | - Heng Yin
- Department of Breast Surgery, Suining Central Hospital, Suining, China
| | - Wenzhi Chen
- State Key Laboratory of Ultrasound in Medicine and Engineering, Chongqing Medical University, Chongqing, China
- Department of Oncology, Chongqing Haifu Hospital, Chongqing, China
| | - Cai Zhang
- State Key Laboratory of Ultrasound in Medicine and Engineering, Chongqing Medical University, Chongqing, China
- Department of Oncology, Chongqing Haifu Hospital, Chongqing, China
- NMPA Key Laboratory for Quality Evaluation of Ultrasonic Surgical Equipment, Wuhan, China
| |
Collapse
|
2
|
DeWitt M, Demir ZEF, Sherlock T, Brenin DR, Sheybani ND. MR Imaging-Guided Focused Ultrasound for Breast Tumors. Magn Reson Imaging Clin N Am 2024; 32:593-613. [PMID: 39322350 DOI: 10.1016/j.mric.2024.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/27/2024]
Abstract
Breast tumors remain a complex and prevalent health burden impacting millions of individuals worldwide. Challenges in treatment arise from the invasive nature of traditional surgery and, in malignancies, the complexity of treating metastatic disease. The development of noninvasive treatment alternatives is critical for improving patient outcomes and quality of life. This review aims to explore the advancements and applications of focused ultrasound (FUS) technology over the past 2 decades. FUS offers a promising noninvasive, nonionizing intervention strategy in breast tumors including primary breast cancer, fibroadenomas, and metastatic breast cancer.
Collapse
Affiliation(s)
- Matthew DeWitt
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA; Focused Ultrasound Cancer Immunotherapy Center, University of Virginia, Charlottesville, VA, USA
| | - Zehra E F Demir
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
| | - Thomas Sherlock
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
| | - David R Brenin
- Focused Ultrasound Cancer Immunotherapy Center, University of Virginia, Charlottesville, VA, USA; Division of Surgical Oncology, University of Virginia Health System, Charlottesville, VA, USA
| | - Natasha D Sheybani
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA; Focused Ultrasound Cancer Immunotherapy Center, University of Virginia, Charlottesville, VA, USA; Department of Radiology & Medical Imaging, University of Virginia, Charlottesville, VA, USA.
| |
Collapse
|
3
|
Boeer B, Oberlechner E, Rottscholl R, Gruber I, Guergan S, Brucker S, Hahn M. Five-year follow-up after a single US-guided high intensity focused ultrasound treatment of breast fibroadenoma. Sci Rep 2024; 14:18370. [PMID: 39112604 PMCID: PMC11306253 DOI: 10.1038/s41598-024-68827-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Accepted: 07/29/2024] [Indexed: 08/10/2024] Open
Abstract
The aim of this study was to evaluate the long-term efficacy of a single ultrasound-guided high-intensity focused ultrasound (US-HIFU) treatment in patients with breast fibroadenoma (FA) in terms of volume and pain reduction as well as palpation findings. From december 2013 until november 2014 27 women with a symptomatic FA were treated in one HIFU-session. Follow-up visits were performed after 7 days, 6 months and 1, 2, 3 and 5 years with clinical examination and ultrasound. One year after the procedure, a core needle biopsy of the residual lesion was offered. There was a significant volume reduction 6 months after HIFU from 1083.10 to 347.13 mm3 (p < 0.0001) with a mean volume reduction ratio (VRR) of 61.63%. Thereafter the FAs showed a further, but no longer significant decrease in size. One patient with an initial incomplete ablation and histologically confirmed persistent vital cells after 1 year showed a strong regrowth after 3 years. Excluding this patient from analysis, the mean VRR at months 12, 24, 36, and 60 was 86.44%, 94.44%, 94.90%, and 97.85%, respectively. Before HIFU, 59.26% of the patients had pain (22.33/100 VAS) which decreased to 6.56/100 after 12 months and remained reduced over the 5 year follow up period. A decrease in palpability from 85.19 to 7.69% was observed within 24 months. A single HIFU intervention let to a substantial reduction in size, pain, and palpability with its most potential effect during the first 12 months. Subsequently, the observed effect remained stable over a 5 year follow up period. Incomplete initial treatment was associated with the risk of regrowth.
Collapse
Affiliation(s)
- B Boeer
- Department of Women's Health, University Hospital of Tuebingen, Calwerstraße 7, 72076, Tübingen, Germany.
| | - E Oberlechner
- Department of Women's Health, University Hospital of Tuebingen, Calwerstraße 7, 72076, Tübingen, Germany
| | - R Rottscholl
- Department of Pathology, University Hospital of Tuebingen, Tübingen, Germany
| | - I Gruber
- Department of Women's Health, University Hospital of Tuebingen, Calwerstraße 7, 72076, Tübingen, Germany
| | - S Guergan
- Department of Women's Health, University Hospital of Tuebingen, Calwerstraße 7, 72076, Tübingen, Germany
| | - S Brucker
- Department of Women's Health, University Hospital of Tuebingen, Calwerstraße 7, 72076, Tübingen, Germany
| | - M Hahn
- Department of Women's Health, University Hospital of Tuebingen, Calwerstraße 7, 72076, Tübingen, Germany
| |
Collapse
|
4
|
Wu X, Yue X, Liu H, Huang H, Yao D, Guo Y, Chen W, Zhang C. Clinical efficacy and safety of ultrasound-guided high-intensity focused ultrasound for breast fibroadenoma: a systematic review and meta-analysis. Int J Hyperthermia 2024; 41:2374874. [PMID: 39053900 DOI: 10.1080/02656736.2024.2374874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 04/12/2024] [Accepted: 06/26/2024] [Indexed: 07/27/2024] Open
Abstract
OBJECTIVE The purpose of this systematic review and meta-analysis was to assess the clinical efficacy and safety of ultrasound (US)-guided high intensity focused ultrasound (HIFU) in the treatment of breast fibroadenoma in different studies. METHODS Studies evaluating the efficacy and safety of US-guided HIFU in the treatment of histologically-proven FA with follow-up outcomes of more than 3 months were searched through MEDLINE/PubMed databases. Volume reduction rate (VRR) and side effects were extracted and compared for further analysis. RESULTS Of 29 identified articles, 10 studies involving 385 women and more than 545 FAs met the inclusion criteria. The mean VRR at 6 months and 12 months after HIFU was 52.00% and 72.00%. In terms of intraoperative safety, nine studies reported mild to moderate pain, with an average visual analogue scale (VAS) score ranging from 1.60 to 7.10. The most common postoperative side effect associated with HIFU was subcutaneous ecchymosis and less frequent were pain, erythema, and skin pigmentation, most of which disappeared within weeks. No serious side effects were observed. CONCLUSION S-guided HIFU is an effective and safe noninvasive treatment for breast FA that does not cause serious side effects. Further studies are needed to explore crucial influencing factors of VRR.
Collapse
Affiliation(s)
- Xiuying Wu
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Xuewen Yue
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Hong Liu
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- NMPA Key Laboratory for Quality Evaluation of Ultrasonic Surgical Equipment, Wuhan, China
| | - Haoran Huang
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- NMPA Key Laboratory for Quality Evaluation of Ultrasonic Surgical Equipment, Wuhan, China
- Chongqing Haifu Hospital, Chongqing, China
| | - Dan Yao
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Yujun Guo
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Wenzhi Chen
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- NMPA Key Laboratory for Quality Evaluation of Ultrasonic Surgical Equipment, Wuhan, China
- Chongqing Haifu Hospital, Chongqing, China
| | - Cai Zhang
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
- NMPA Key Laboratory for Quality Evaluation of Ultrasonic Surgical Equipment, Wuhan, China
- Chongqing Haifu Hospital, Chongqing, China
| |
Collapse
|
5
|
Gonnah AR, Masoud O, AbdelWahab M, ElMosalamy A, Al-Naseem A. The Role of High Intensity Focused Ultrasound in the Treatment of Fibroadenomas: A Systematic Review. Breast Care (Basel) 2023; 18:279-288. [PMID: 37900548 PMCID: PMC10601662 DOI: 10.1159/000524738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Accepted: 04/21/2022] [Indexed: 10/31/2023] Open
Abstract
Introduction Fibroadenomas are solid, mobile, and non-tender benign breast lumps, with highest prevalence amongst young women aged between 15 and 35. Symptoms can include discomfort, and they can become problematic, particularly when they enlarge, resulting in many referrals for biopsies, with fibroadenomas accounting for 30-75% of the cases. Diagnosis is based on triple assessment that involves a clinical examination, ultrasound imaging, and mammography, as well as core needle biopsies. Current management includes observation for 6-12 months, with the indication of definitive surgery, in cases that are older than 35 years or with fibroadenoma persistence. Serious adverse effects of surgery might include nipple areolar distortion, scarring, and damage to the breast tissue, as well as the risks associated with surgery and anesthesia, making it a non-feasible option. Methods A literature search was performed on the databases Embase, MEDLINE/PubMed, Google Scholar, and Ovid for English language papers published between January 1, 2000, and March 17, 2021. A structured protocol was employed to devise a comprehensive search strategy with keywords and Boolean operators defined by the research question. The keywords used for the search were "HIFU", "High Intensity Focused Ultrasound," "Fibroadenoma," "Breast," "Lesion." This review was carried out in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Results Recently, a thermal ablative technique, high intensity focused ultrasound (HIFU), was found to be a safe, noninvasive, and technically successful alternative, having displayed promising outcomes in reducing the volume of fibroadenomas, pain experienced by patients, and the length of hospitalization. Quality of life improvement was also evidenced, exhibited by the disappearance of symptoms, and enhanced physical activity post-intervention, in addition to patients' satisfaction with the cosmetic results and future recommendation of the procedure to other patients. Conclusion Overall, HIFU is a well-tolerated treatment associated, with low risk of complications, that can potentially include erythema, skin discoloration, and bruising with the majority of these self-resolving shortly after the procedure.
Collapse
Affiliation(s)
| | - Omar Masoud
- Faculty of Life Sciences and Medicine, King’s College London, London, UK
| | | | | | | |
Collapse
|
6
|
Liang M, Zhang C, Xia T, Chen R, Wang X, Weng M, Xie H, Chen L, Liu X, Wang S. Ultrasound radiomics features predicting the dosimetry for focused ultrasound surgery of benign breast tumor: A retrospective study. Front Genet 2022; 13:969409. [PMID: 36118892 PMCID: PMC9479455 DOI: 10.3389/fgene.2022.969409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 08/17/2022] [Indexed: 12/03/2022] Open
Abstract
Purpose: To investigate the correlation between pre-ablation ultrasound radiomics features and the sonication energy for focused ultrasound surgery (FUS) of benign breast tumors. Method: 53 benign breast tumors of 28 patients treated by ultrasound-guided focused ultrasound surgery (USgFUS) were included in this study. The sonication energy per unit volume of each tumor was calculated. Three-quarter point was chosen as the cut-off to divide the 53 included tumors into high sonication energy (HSE, n = 14) and low sonication energy (LSE, n = 39) groups. For each tumor, the region of interest (ROI) of both the tumor itself (tROI) and the near field tissue (nfROI) were delineated and analyzed separately using ImageJ software. Pearson correlation coefficient and multiple linear regression analysis were used for radiomics feature selection. To explore the diagnostic performance of different ultrasound radiomics features, a receiver operating characteristic (ROC) curve analysis was performed. Results: In total of 68 radiomics features were extracted from pre-ablation ultrasound images of each tumor. Of all radiomics features, BX in tROI (p < 0.001), BX (p = 0.001) and Circ (p = 0.019) in nfROI were independently predictive features of sonication energy per unit volume. The ROC curves showed that the area under the curve (AUC) values of BX in tROI, BX, and Circ in nfROI were 0.797, 0.787 and 0.822, respectively. Conclusion: This study provided three radiomics features of pre-ablation ultrasound image as predictors of sonication dose for FUS in benign breast tumors. Further clinical trials are needed to confirm the predictive effect of these radiomics features.
Collapse
Affiliation(s)
- Mengdi Liang
- Department of Breast Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Cai Zhang
- State Key Laboratory of Ultrasound in Medicine and Engineering, Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Tiansong Xia
- Department of Breast Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
- State Key Laboratory of Ultrasound in Medicine and Engineering, Chongqing Medical University, Chongqing, China
- Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Rui Chen
- Department of Breast Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Xinyang Wang
- Department of Breast Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Miaomiao Weng
- Department of Breast Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Hui Xie
- Department of Breast Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Lin Chen
- Department of Breast Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Xiaoan Liu
- Department of Breast Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
- *Correspondence: Xiaoan Liu, ; Shui Wang,
| | - Shui Wang
- Department of Breast Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
- *Correspondence: Xiaoan Liu, ; Shui Wang,
| |
Collapse
|
7
|
Co M, Chen C, Lee C, Yu S, Kwong A. Prospective clinical trial on the learning curve of high-intensity-focused ultrasound for the treatment of breast fibroadenoma. Surg Today 2022; 52:1048-1053. [PMID: 35000002 DOI: 10.1007/s00595-021-02421-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Accepted: 10/18/2021] [Indexed: 11/25/2022]
Abstract
INTRODUCTION High-intensity-focused ultrasound (HIFU) is a safe and feasible treatment option for breast fibroadenoma. However, its learning curve has not been described in the medical literature. METHODS All patients with biopsy-proven fibroadenoma considered indicated for HIFU were screened for eligibility for HIFU treatment. A total of 60 patients were recruited according to the pre-defined sample size calculation. RESULTS Sixty consecutive patients were divided into three cohorts in chronological order. The mean tumor volume shrinkage rates in cohorts 1, 2, and 3 at 6 months post-HIFU ablation were 38%, 34%, and 59%, respectively. Significant tumor shrinkage was observed from case 41 onward (p < 0.0001). Similarly, the mean tumor volume shrinkage rates in cohorts 1, 2, and 3 at 12 months post-HIFU ablation were 45%, 51%, and 71%, respectively. Significant tumor shrinkage was observed from case 41 onwards (p < 0.0473). The mean procedure time for the first 20 patients was 48.5 (range 45-75) minutes, while that in the second 20 patients was 39.7 (range 20-60) minutes, and that in the last 20 patients was 28.9 (range 15-45) minutes. The treatment time was significantly shorter from case 41 onwards (p = 0.0481). CONCLUSION Treatment outcomes and treatment time improved significantly after performing approximately 40 HIFU procedures.
Collapse
Affiliation(s)
- Michael Co
- Department of Surgery, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong, China
| | - Clement Chen
- Department of Surgery, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong, China
| | - Cassandra Lee
- Department of Surgery, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong, China
| | - Stephanie Yu
- Department of Surgery, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong, China
| | - Ava Kwong
- Department of Surgery, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong, China.
| |
Collapse
|