1
|
Henriksson HB, Hellström A, Nilsson AK, Sjöbom U, Jönsson B, Frändberg S. Bacterial species in cord blood and their significance in the context of clinical use. Transfus Apher Sci 2024; 63:103961. [PMID: 38981148 DOI: 10.1016/j.transci.2024.103961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 06/12/2024] [Accepted: 06/14/2024] [Indexed: 07/11/2024]
Abstract
Approximately 90 % of infants born before 28 full weeks(extremely-preterm-infants) receive erythrocyte transfusions in early life. Umbilical cord blood(UCB) has been investigated as an alternative source for erythrocyte transfusions to preterm neonates. This retrospective study aimed to compile/evaluate spectrum of bacteria groups/species intermittently detected in processed UCB at National-Swedish-Cord blood bank, (NS-CBB) during the years 2008-2020. Consecutive data from the years 2008-2020 were investigated. UCB from healthy newborns born after 37 full weeks of gestation was collected following clamping of cord (1 min) through cannulation of umbilical vein(vaginal-and C-section-deliveries). In total, 5194 cord blood units (UCBUs) that met NS-CBB-guidelines for total nucleated-cell-content(TNC) were manufactured from 8875 collections. Of 5194 UCBUs,77,6 % were from vaginal-and 22,4 % from C-section deliveries.Samples(10 mL) were collected from surplus eryhtrocyte fraction post-processing(n = 5194), transferred into BACT/ALERT® aerobic/anaerobic culture flasks and monitored 10 days using BACT/ALERT®-3D-Microbial-Detection-Systems. Positive samples were subcultured and typed for bacterial groups and/or species. Out of 5194 processed sampled UCB units,186 (3,6 %) were discarded due to positive sterility tests, 92 % were detected in samples from vaginal-deliveries and 8 % from C-section-deliveries. In all,16 different groups of bacteria and 27 species were identified. Common bacterial/groups and species were anaerobe gram-negative rods(n = 28),coagulase-negative-staphylococci(n = 21),gram-positive rods(n = 21),anaerobe-gram-positive cocci(n = 20) and viridans-streptococci(n = 13). Extracted from these results,in positive samples(n = 13) from C-section deliveries, bacteria were found:viridans-streptococci(n = 7),Aerococcus-urinae(n = 1), Staphylococcus lugdunensis(n = 1),other coagulase-negative staphylococci(n = 1) or a mix of aerobic/anaerobic bacteria(n = 3). Our results are in alignment with previously published contamination rates in processed UCBUs. Still, results point towards importance of strict microbial monitoring when manufacturing UCBUs to achieve patient-safe- products for stem-cell transplantation/transfusion.
Collapse
Affiliation(s)
- Helena Barreto Henriksson
- Department of Laboratory Medicine, Institute of Biomedicine, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Region Västra Götaland, Sahlgrenska University Hospital, Department of Research, Development, Education and Innovation, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Ann Hellström
- The Sahlgrenska Centre for Pediatric Ophthalmology Research, Department of Clinical Neuroscience, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Anders K Nilsson
- The Sahlgrenska Centre for Pediatric Ophthalmology Research, Department of Clinical Neuroscience, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Ulrika Sjöbom
- The Sahlgrenska Centre for Pediatric Ophthalmology Research, Department of Clinical Neuroscience, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Learning and Leadership for Health Care Professionals at the Institute of Health and Care Science at Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden
| | - Bodil Jönsson
- Department of Clinical Microbiology, Sahlgrenska University Hospital, Gothenburg, Sweden; Department of Clinical Immunology and Transfusion Medicine, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Sofia Frändberg
- Department of Laboratory Medicine, Institute of Biomedicine, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Clinical Immunology and Transfusion Medicine, Sahlgrenska University Hospital, Gothenburg, Sweden.
| |
Collapse
|
2
|
Reuther S, Floegel K, Ceusters G, Albertini V, Baran J, Dempke W. OUP accepted manuscript. Stem Cells Transl Med 2022; 11:604-612. [PMID: 35486383 PMCID: PMC9216499 DOI: 10.1093/stcltm/szac020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Accepted: 03/06/2022] [Indexed: 12/01/2022] Open
Abstract
Cord blood (CB) collected at birth has become a valuable stem cell source for hematopoietic stem cell transplantation (HSCT). However, the collection of umbilical cord blood always bears a risk of microbiological contamination, both in vaginal birth and in cesarean section. A total of 10 054 umbilical cord stem cell samples were successfully cryopreserved between 2010 and 2020, of which 783 (8%) samples were tested positive for bacterial contamination. Umbilical CB with a volume of less than 60 mL showed a bacterial contamination rate of 12%, and above 60 mL volume a rate of 6% was found demonstrating an inverse relationship between sample volume and contamination rate (correlation coefficient r = −0.9). The contamination rate was associated with the mode of delivery and showed a significantly higher contamination rate of 9.7% when compared with cesarean deliveries (1.4%). The 10-year period consistently shows an average contamination rate between 4% and 6% per year. It is conceivable that the inverse relationship between volume and contamination rate might be related to thinner veins although no scientific evidence has been provided so far. The lower contamination rate in cesarean sections appears to be related to the sterile operating setting. Overall, the rate of bacterial contamination varies and depends on the type of birth, the way of delivery, and probably the experience of the staff.
Collapse
Affiliation(s)
- Susanne Reuther
- Eticur Germany GmbH, Munich, Germany
- Ludwig-Maximillians University Munich, Munich, Germany
| | | | - Gunther Ceusters
- Eticur Germany GmbH, Munich, Germany
- Famicord SA Suisse, Contone, Switzerland
| | | | | | - Wolfram Dempke
- Corresponding author: Wolfram Dempke, MD, PhD, MBA, Professor of Hematology & Oncology, Worldwide Clinical Trials, Waterfront House, Beeston Business Park, Nottingham NG9 1LA, UK. Tel: +41 797 836 706; Fax: +44 207 121 6160;
| |
Collapse
|
3
|
Boey KPY, Zhu P, Tan H, Abdullah MAB, Tang KF, Li MM, Loke I, Hariharan M. Effects of cryopreservation on gram-positive bacteria contaminants in umbilical cord blood. Transfus Med 2021; 32:82-87. [PMID: 34862686 DOI: 10.1111/tme.12834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 11/02/2021] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To evaluate the effects of cryopreservation in post-thaw umbilical cord blood units for the survivability of Gram-positive bacteria strains. BACKGROUND Microbial screening is required for all cord blood units (CBUs). Four gram-positive contaminants were documented to survive cryopreservation poorly and isolation of other contaminants were reported. METHODS Forty-eight contaminated CBUs detected with either Staphylococcus epidermidis, Corynebacterium species, Peptostreptococcus or Streptococcus species before cryopreservation were used in this study. CBUs were processed, DMSO-infused and microbial screened before cryopreservation. Post-thaw microbial screening was achieved using 1 and 10 ml inoculants in BACTEC culture bottles. Positive bottles were subjected for microbial identification and results were compared with those from pre-freeze. RESULTS A higher rate of microbial contamination was found using the 10 ml inoculant. Screening of 11 CBUs did not detect any contaminants while 30 CBUs screened detected more than one unknown contaminants and majority of contaminants were identified to be gram-negative species. CONCLUSION A higher inoculation volume used at post-thaw for microbial screening improves contamination detection but leads to the loss of precious cord blood. Some contaminants did not survive cryopreservation or were not identified due to their low microbial levels. Contrasting contaminants found at post-thaw suggest the improvements made in detection and identification of contaminants over the years.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Ian Loke
- Cordlife Group Limited, Singapore, Singapore
| | | |
Collapse
|
4
|
Microbial contamination risk in hematopoietic stem cell products: retrospective analysis of 1996–2016 data. ACTA ACUST UNITED AC 2020. [DOI: 10.2478/ahp-2020-0007] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
AbstractQuality assurance and safety of hematopoietic stem cells (HSC) with special emphasis on bacterial and fungal contamination is the prerequisite for any transplantation procedure. The aim was to determine the incidence rate of such contamination during processing of transplantation material with regard to HSC source: peripheral blood stem cell (PBSC), bone marrow (BM), or cord blood (CB). Analysis involved autologous and allogenic products dedicated for patients and comprised in all 4135 donations, including 112 BM (2.70%), 3787 PBSC (91.60%), and 236 CB (5.70%) processed in cell bank over the period 1996–2016. Aerobic and anaerobic contamination was determined.Analysis of the 20-year data revealed 42 contaminated products: 25 PBSC (0.66% of tested units) and 17 CB (7.20% of tested units). No microbial contamination of BM products was detected. Overall percentage of contaminated products was 1.01%, mostly with Staphylococcus epidermidis (61.36%). Bacterial contamination rate at cell bank is relatively low and processing in a closed system does not seem as crucial as might be expected. This is particularly true for BM components. Equally important are evaluation of donor’s medical status and condition of the puncture site for collection of source material. Implementation of appropriate sample collection procedures should help minimize the risk of false-positive results due to environmental contamination.
Collapse
|
5
|
Kou Y, Halpenny M, Elmoazzen H, Ramirez-Arcos S. Development of a proof of principle for universal neutralization of antibiotics in cord blood by-products used for sterility testing. Transfusion 2018; 58:1421-1426. [PMID: 29516509 DOI: 10.1111/trf.14567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Revised: 12/19/2017] [Accepted: 01/22/2018] [Indexed: 12/01/2022]
Abstract
BACKGROUND Bacterial contamination of cord blood (CB) represents a safety risk for transplantation patients. CB sterility testing at Canadian Blood Services' Cord Blood Bank is performed using a 1:1 mix of CB-derived plasma and red blood cells (RBCs). Culture bottles of an automated culture system, which lack antimicrobial neutralization properties, are used for bacterial screening of CB. This process is unsuitable for CB-containing antibiotics, potentially resulting in false-negative results. This study was aimed at developing a protocol for antibiotic neutralization in CB used for sterility testing. STUDY DESIGN AND METHODS Phase 1: four neutralizers-penicillinase, ion exchange resins L and A, lecithin + Tween80, and activated charcoal (AC)-were individually tested to neutralize penicillin or gentamicin in cultures of Staphylococcus epidermidis or Klebsiella pneumoniae, respectively, adjusted to 100 colony forming units/mL, in Müller-Hinton broth (MHB). Phase 2: combinations of penicillinase plus resin L or penicillinase plus AC were assayed for the simultaneous neutralization of both antibiotics in MHB. Phase 3: penicillinase plus resin L was used to neutralize both antibiotics in CB sterility testing samples (plasma + RBCs). RESULTS Phase 1: penicillin was neutralized by penicillinase and resin A, while gentamicin was neutralized by resin L and AC. Phase 2: the antibiotics were simultaneously neutralized by the two neutralizer combinations tested. Phase 3: neutralization of both antibiotics in CB was achieved with penicillinase and resin L. CONCLUSION A protocol for antibiotic neutralization in CB sterility testing samples has been successfully developed at Canadian Blood Services' Cord Blood bank. This in-house assay applies to any culture-based CB bacterial screening method.
Collapse
Affiliation(s)
- Yuntong Kou
- Canadian Blood Services Centre for Innovation, Product and Process Development, Ottawa, Ontario
| | - Mike Halpenny
- Canadian Blood Services' Cord Blood Bank, Ottawa, Ontario
| | | | - Sandra Ramirez-Arcos
- Canadian Blood Services Centre for Innovation, Product and Process Development, Ottawa, Ontario
| |
Collapse
|