2
|
Spindler-Raffel E, Benjamin RJ, McDonald CP, Ramirez-Arcos S, Aplin K, Bekeredjian-Ding I, de Korte D, Gabriel C, Gathof B, Hanschmann KM, Hourfar K, Ingram C, Jacobs MR, Keil SD, Kou Y, Lambrecht B, Marcelis J, Mukhtar Z, Nagumo H, Niekerk T, Rojo J, Marschner S, Satake M, Seltsam A, Seifried E, Sharafat S, Störmer M, Süßner S, Wagner SJ, Yomtovian R. Enlargement of the WHO international repository for platelet transfusion-relevant bacteria reference strains. Vox Sang 2017; 112:713-722. [PMID: 28960367 DOI: 10.1111/vox.12548] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2017] [Revised: 05/25/2017] [Accepted: 05/26/2017] [Indexed: 11/28/2022]
Abstract
BACKGROUND AND OBJECTIVES Interventions to prevent and detect bacterial contamination of platelet concentrates (PCs) have reduced, but not eliminated the sepsis risk. Standardized bacterial strains are needed to validate detection and pathogen reduction technologies in PCs. Following the establishment of the First International Reference Repository of Platelet Transfusion-Relevant Bacterial Reference Strains (the 'repository'), the World Health Organization (WHO) Expert Committee on Biological Standardisation (ECBS) endorsed further repository expansion. MATERIALS AND METHODS Sixteen bacterial strains, including the four repository strains, were distributed from the Paul-Ehrlich-Institut (PEI) to 14 laboratories in 10 countries for enumeration, identification and growth measurement on days 2, 4 and 7 after low spiking levels [10-25 colony-forming units (CFU)/PC bag]. Spore-forming (Bacillus cereusPEI-B-P-07-S, Bacillus thuringiensisPEI-B-P-57-S), Gram-negative (Enterobacter cloacaePEI-B-P-43, Morganella morganiiPEI-B-P-74, PEI-B-P-91, Proteus mirabilisPEI-B-P-55, Pseudomonas fluorescensPEI-B-P-77, Salmonella choleraesuisPEI-B-P-78, Serratia marcescensPEI-B-P-56) and Gram-positive (Staphylococcus aureusPEI-B-P-63, Streptococcus dysgalactiaePEI-B-P-71, Streptococcus bovisPEI-B-P-61) strains were evaluated. RESULTS Bacterial viability was conserved after transport to the participating laboratories with one exception (M. morganiiPEI-B-P-74). All other strains showed moderate-to-excellent growth. Bacillus cereus, B. thuringiensis, E. coli, K. pneumoniae, P. fluorescens, S. marcescens, S. aureus and S. dysgalactiae grew to >106 CFU/ml by day 2. Enterobacter cloacae, P. mirabilis, S. epidermidis, S. bovis and S. pyogenes achieved >106 CFU/ml at day 4. Growth of S. choleraesuis was lower and highly variable. CONCLUSION The WHO ECBS approved all bacterial strains (except M. morganiiPEI-B-P-74 and S. choleraesuisPEI-B-P-78) for repository enlargement. The strains were stable, suitable for spiking with low CFU numbers, and proliferation was independent of the PC donor.
Collapse
Affiliation(s)
| | | | - C P McDonald
- National Health Service Blood and Transplant, London, UK
| | | | - K Aplin
- National Health Service Blood and Transplant, London, UK
| | | | - D de Korte
- Sanquin Blood Supply Foundation, Amsterdam, The Netherlands
| | - C Gabriel
- Blood Centre Linz, Austrian Red Cross, Linz, Austria
| | - B Gathof
- Institute of Transfusion Medicine, University Hospital of Cologne, Cologne, Germany
| | | | - K Hourfar
- German Red Cross, Frankfurt/Main, Germany
| | - C Ingram
- Constantia Kloof, South African National Blood Service, Johannesburg, South Africa
| | - M R Jacobs
- Case Western Reserve University, Cleveland, OH, USA
| | - S D Keil
- Terumo BCT Biotechnologies, Lakewood, CO, USA
| | - Y Kou
- Canadian Blood Service, Ottawa, ON, Canada
| | - B Lambrecht
- German Red Cross Blood Service NSTOB, Springe, Germany
| | - J Marcelis
- Elisabeth Hospital, Tilburg, The Netherlands
| | - Z Mukhtar
- Dow Safe Blood Transfusion Services, DUHS, Khi, Pakistan
| | - H Nagumo
- Japanese Red Cross, Tokyo, Japan
| | - T Niekerk
- Constantia Kloof, South African National Blood Service, Johannesburg, South Africa
| | - J Rojo
- Centro Nacional de la Transfusión Sanguínea, Mexico, Mexico
| | - S Marschner
- Terumo BCT Biotechnologies, Lakewood, CO, USA
| | - M Satake
- Japanese Red Cross, Tokyo, Japan
| | - A Seltsam
- German Red Cross Blood Service NSTOB, Springe, Germany
| | - E Seifried
- German Red Cross, Frankfurt/Main, Germany
| | - S Sharafat
- Dow University of Health Sciences, Khi, Pakistan
| | - M Störmer
- Institute of Transfusion Medicine, University Hospital of Cologne, Cologne, Germany
| | - S Süßner
- Blood Centre Linz, Austrian Red Cross, Linz, Austria
| | - S J Wagner
- Holland Laboratory, Transfusion Innovation Department, American Red Cross, Rockville, MD, USA
| | - R Yomtovian
- Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, USA
| | | |
Collapse
|