1
|
Qi L, Zhu W, Qian W, Xu L, He Y, Zhao F. The Performance of a Spherical-tip Catheter for Stent Post-dilation: Finite Element Analysis and Experiments. Front Physiol 2021; 12:734565. [PMID: 34531765 PMCID: PMC8438231 DOI: 10.3389/fphys.2021.734565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Accepted: 07/26/2021] [Indexed: 11/30/2022] Open
Abstract
At present, percutaneous coronary intervention (PCI) is the most effective treatment of coronary artery stenosis. However, in case post-dilation of the stent is needed, the tip of the commonly used post-dilation balloon catheter cannot always pass through the stent smoothly, especially when it is situated in the curved part of the vessel. To improve the performance of traditional post-dilation balloon catheter, a preliminary design of a novel catheter with a spherical-tip is proposed. Since the performance of this spherical-tip catheter is still unclear, in this study, finite element analysis (FEA) and experimental validation of blood vessel with different curvature radii were performed to test and evaluate the performance of the spherical-tip catheter design. The comparative results between the two types of catheters demonstrate that in the simulated post-dilation process, the spherical-tip catheter is easier to pass through the stent placed in the curved vessel without the deformation of the stent strut, and can theoretically reduce the operation time and improve the safety of the operation. Furthermore, the strong consistency between simulation and experiment indicates that the finite element (FE) model can be a helpful tool for future optimization and evaluation of novel catheters, so as to save time and budget in product development and reduce/replace animal studies.
Collapse
Affiliation(s)
- Lin Qi
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, China.,Engineering Research Center of Medical Imaging and Intelligent Analysis, Ministry of Education, Northeastern University, Shenyang, China.,Key Laboratory of Medical Image Computing, Ministry of Education, Northeastern University, Shenyang, China
| | - Wenbo Zhu
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| | - Wei Qian
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, China
| | - Lisheng Xu
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, China.,Engineering Research Center of Medical Imaging and Intelligent Analysis, Ministry of Education, Northeastern University, Shenyang, China.,Key Laboratory of Medical Image Computing, Ministry of Education, Northeastern University, Shenyang, China
| | - Ying He
- School of Energy and Power Engineering, Dalian University of Technology, Dalian, China
| | - Feihu Zhao
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands.,Department of Biomedical Engineering, Zienkiewicz Centre for Computational Engineering, Faculty of Science and Engineering, Swansea University, Swansea, United Kingdom
| |
Collapse
|
2
|
Yadollahi-Farsani H, Scougal E, Herrmann M, Wei W, Frakes D, Chong B. Numerical study of hemodynamics in brain aneurysms treated with flow diverter stents using porous medium theory. Comput Methods Biomech Biomed Engin 2019; 22:961-971. [DOI: 10.1080/10255842.2019.1609457] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
| | - Erik Scougal
- School for Engineering of Matter Transport and Energy, Arizona State University, Tempe, AZ, USA
| | - Marcus Herrmann
- School for Engineering of Matter Transport and Energy, Arizona State University, Tempe, AZ, USA
| | - Wei Wei
- School for Engineering of Matter Transport and Energy, Arizona State University, Tempe, AZ, USA
| | - David Frakes
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ, USA
- School of Electrical Computer and Energy Engineering, Arizona State University, Tempe, AZ, USA
| | - Brian Chong
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ, USA
- Department of Radiology, Mayo Clinic Hospital, Phoenix, AZ, USA
| |
Collapse
|
3
|
Kanberoglu B, Das D, Nair P, Turaga P, Frakes D. An Optical Flow-Based Approach for Minimally Divergent Velocimetry Data Interpolation. Int J Biomed Imaging 2019; 2019:9435163. [PMID: 30863431 PMCID: PMC6378004 DOI: 10.1155/2019/9435163] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Revised: 12/04/2018] [Accepted: 12/10/2018] [Indexed: 12/03/2022] Open
Abstract
Three-dimensional (3D) biomedical image sets are often acquired with in-plane pixel spacings that are far less than the out-of-plane spacings between images. The resultant anisotropy, which can be detrimental in many applications, can be decreased using image interpolation. Optical flow and/or other registration-based interpolators have proven useful in such interpolation roles in the past. When acquired images are comprised of signals that describe the flow velocity of fluids, additional information is available to guide the interpolation process. In this paper, we present an optical-flow based framework for image interpolation that also minimizes resultant divergence in the interpolated data.
Collapse
Affiliation(s)
- Berkay Kanberoglu
- School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, 85281, USA
| | - Dhritiman Das
- Department of Computer Science, Technical University of Munich, Munich, 80333, Germany
| | - Priya Nair
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, 85281, USA
| | - Pavan Turaga
- School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, 85281, USA
- School of Arts, Media and Engineering, Arizona State University, Tempe, 85281, USA
| | - David Frakes
- School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, 85281, USA
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, 85281, USA
| |
Collapse
|
4
|
Mine B, Bonnet T, Vazquez-Suarez JC, Iosif C, Lubicz B. Comparison of stents used for endovascular treatment of intracranial aneurysms. Expert Rev Med Devices 2018; 15:793-805. [DOI: 10.1080/17434440.2018.1538779] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Benjamin Mine
- Department of Interventional Neuroradiology, University Hospital Erasme, Brussels, Belgium
| | - Thomas Bonnet
- Department of Interventional Neuroradiology, University Hospital Erasme, Brussels, Belgium
| | | | - Christina Iosif
- Department of Interventional Neuroradiology, University Hospital Erasme, Brussels, Belgium
| | - Boris Lubicz
- Department of Interventional Neuroradiology, University Hospital Erasme, Brussels, Belgium
| |
Collapse
|
5
|
Alkhalili K, Hannallah J, Cobb M, Chalouhi N, Philips JL, Echeverria AB, Jabbour P, Babiker MH, Frakes DH, Gonzalez LF. The Effect of Stents in Cerebral Aneurysms: A Review. Asian J Neurosurg 2018; 13:201-211. [PMID: 29682009 PMCID: PMC5898080 DOI: 10.4103/1793-5482.175639] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
The etiology of up to 95% of cerebral aneurysms may be accounted for by hemodynamically-induced factors that create vascular injury. The purpose of this review is to describe key physical properties that stents have and how they affect cerebral aneurysms. We performed a two-step screening process. First, a structured search was performed using the PubMed database. The following search terms and keywords were used: “Hemodynamics,” “wall shear stress (WSS),” “velocity,” “viscosity,” “cerebral aneurysm,” “intracranial aneurysm,” “stent,” “flow diverter,” “stent porosity,” “stent geometry,” “stent configuration,” and “stent design.” Reports were considered if they included original data, discussed hemodynamic changes after stent-based treatment of cerebral aneurysms, examined the hemodynamic effects of stent deployment, and/or described the geometric characteristics of both stents and the aneurysms they were used to treat. The search strategy yielded a total of 122 articles, 61 were excluded after screening the titles and abstracts. Additional articles were then identified by cross-checking reference lists. The final collection of 97 articles demonstrates that the geometric characteristics and configurations of deployed stents influenced hemodynamic parameters such as aneurysmal WSS, inflow, and pressure. The geometric characteristics of the aneurysm and its position also had significant influences on intra-aneurysmal hemodynamics after treatment. In conclusion, changes in specific aneurysmal hemodynamic parameters that result from stenting relate to a number of factors including the geometric properties and configurations of deployed stents, the geometric properties of the aneurysm, and the pretreatment hemodynamics.
Collapse
Affiliation(s)
- Kenan Alkhalili
- Department of Surgery, University of Arizona, Tucson, Arizona, USA
| | - Jack Hannallah
- Department of Surgery, University of Arizona, Tucson, Arizona, USA
| | - Mary Cobb
- Division of Neurosurgery, Duke University, Durham, NC, USA
| | - Nohra Chalouhi
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, PA, USA
| | - Jessica L Philips
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, PA, USA
| | | | - Pascal Jabbour
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, PA, USA
| | | | - David H Frakes
- Division of Neurosurgery, Duke University, Durham, NC, USA
| | | |
Collapse
|
6
|
Jou LD. In vitro digital subtraction angiographic evaluation of flow diverters in a patient-specific aneurysm. Interv Neuroradiol 2017; 23:260-266. [PMID: 28604187 DOI: 10.1177/1591019917694023] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background The importance of both porosity and pore density of a flow diverter is well recognized in treatment of intracranial aneurysms; however, understanding of the effect of individual wire (wire number and size) is critical in improving device design and use. Methods A total of 10 multi-layered flow diverters with different wire numbers (32, 48, 56, and 72) and sizes (30, 35, and 40 µm) were implanted into identical patient-specific middle cerebral artery aneurysm models. Digital subtraction angiography was acquired at 30 f/s and X-ray signals at three selected regions of interest were compared to determine the amount of intra-aneurysmal flow. Results Flow reduction ranged from 19% for a high porosity (82%) and low pore density (5 pores/mm2) to nearly 80% for a low porosity (49%) and high pore density (36 pores/mm2). An increase in the wire number from 32 to 72 lowers intra-aneurysmal flow and redirects the flow jet; however, the effect of wire size is not observed. Conclusions In our in vitro angiographic study, flow jet is influenced by the wire number in a device qualitatively; quantitatively, intra-aneurysmal flow is affected by both the porosity and pore density. A 2.5 mm device performs better in flow diversion of a middle cerebral artery (MCA) aneurysm than a 3 mm device with the same wire size and wire number, but thicker wires do not lead to better flow diversion.
Collapse
Affiliation(s)
- Liang-Der Jou
- Department of Neurosurgery, Houston Methodist Hospital, Houston, TX, USA
| |
Collapse
|
7
|
Sarrami-Foroushani A, Lassila T, Frangi AF. Virtual endovascular treatment of intracranial aneurysms: models and uncertainty. WILEY INTERDISCIPLINARY REVIEWS-SYSTEMS BIOLOGY AND MEDICINE 2017; 9. [PMID: 28488754 DOI: 10.1002/wsbm.1385] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2016] [Revised: 01/09/2017] [Accepted: 02/07/2017] [Indexed: 01/11/2023]
Abstract
Virtual endovascular treatment models (VETMs) have been developed with the view to aid interventional neuroradiologists and neurosurgeons to pre-operatively analyze the comparative efficacy and safety of endovascular treatments for intracranial aneurysms. Based on the current state of VETMs in aneurysm rupture risk stratification and in patient-specific prediction of treatment outcomes, we argue there is a need to go beyond personalized biomechanical flow modeling assuming deterministic parameters and error-free measurements. The mechanobiological effects associated with blood clot formation are important factors in therapeutic decision making and models of post-treatment intra-aneurysmal biology and biochemistry should be linked to the purely hemodynamic models to improve the predictive power of current VETMs. The influence of model and parameter uncertainties associated to each component of a VETM is, where feasible, quantified via a random-effects meta-analysis of the literature. This allows estimating the pooled effect size of these uncertainties on aneurysmal wall shear stress. From such meta-analyses, two main sources of uncertainty emerge where research efforts have so far been limited: (1) vascular wall distensibility, and (2) intra/intersubject systemic flow variations. In the future, we suggest that current deterministic computational simulations need to be extended with strategies for uncertainty mitigation, uncertainty exploration, and sensitivity reduction techniques. WIREs Syst Biol Med 2017, 9:e1385. doi: 10.1002/wsbm.1385 For further resources related to this article, please visit the WIREs website.
Collapse
Affiliation(s)
- Ali Sarrami-Foroushani
- Center for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), The University of Sheffield, Sheffield, UK
| | - Toni Lassila
- Center for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), The University of Sheffield, Sheffield, UK
| | - Alejandro F Frangi
- Center for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), The University of Sheffield, Sheffield, UK
| |
Collapse
|
8
|
Nair P, Chong BW, Indahlastari A, Ryan J, Workman C, Haithem Babiker M, Yadollahi Farsani H, Baccin CE, Frakes D. Hemodynamic Characterization of Geometric Cerebral Aneurysm Templates Treated With Embolic Coils. J Biomech Eng 2016; 138:021011. [PMID: 26593324 DOI: 10.1115/1.4032046] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2015] [Indexed: 11/08/2022]
Abstract
Embolic coiling is one of the most effective treatments for cerebral aneurysms (CAs), largely due to the hemodynamic modifications that the treatment effects in the aneurysmal environment. However, coiling can have very different hemodynamic outcomes in aneurysms with different geometries. Previous work in the field of biofluid mechanics has demonstrated on a general level that geometry is a driving factor behind aneurysmal hemodynamics. The goal of this study was to relate two specific geometric factors that describe CAs (i.e., dome size (DS) and parent-vessel contact-angle (PV-CA)) and one factor that describes treatment (i.e., coil packing density (PD)) to three clinically relevant hemodynamic responses (i.e., aneurysmal root-mean-square velocity (Vrms), aneurysmal wall shear stress (WSS), and cross-neck flow (CNF)). Idealized models of basilar tip aneurysms were created in both virtual and physical forms to satisfy two-level multifactorial experimental designs. Steady and pulsatile flow hemodynamics were then evaluated in the virtual models using computational fluid dynamics (CFD) (before and after virtual treatment with finite element (FE) embolic coil models), and hemodynamics were also evaluated in the physical models using particle image velocimetry (PIV) (before and after treatment with actual embolic coils). Results showed that among the factors considered, PD made the greatest contributions to effects on hemodynamic responses in and around the aneurysmal sac (i.e., Vrms and WSS), while DS made the greatest contributions to effects on hemodynamics at the neck (i.e., CNF). Results also showed that while a geometric factor (e.g., PV-CA) may play a relatively minor role in dictating hemodynamics in the untreated case, the same factor can play a much greater role after coiling. We consider the significance of these findings in the context of aneurysmal recurrence and rupture, and explore potential roles for the proposed methods in endovascular treatment planning.
Collapse
|