Chen J, Huang X, Wang J, Chen W, Teng Y, Yin D. Incorporation of black phosphorus nanosheets into poly(propylene fumarate) biodegradable bone cement to enhance bioactivity and osteogenesis. J Orthop Surg Res 2024; 19:98. [PMID: 38291442 PMCID: PMC10829309 DOI: 10.1186/s13018-024-04566-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Accepted: 01/16/2024] [Indexed: 02/01/2024] Open
Abstract
BACKGROUND Injectable bone cement is commonly used in clinical orthopaedics to fill bone defects, treat vertebral compression fractures, and fix joint prostheses during joint replacement surgery. Poly(propylene fumarate) (PPF) has been proposed as a biodegradable and injectable alternative to polymethylmethacrylate (PMMA) bone cement. Recently, there has been considerable interest in two-dimensional (2D) black phosphorus nanomaterials (BPNSs) in the biomedical field due to their excellent photothermal and osteogenic properties. In this study, we investigated the biological and physicochemical qualities of BPNSs mixed with PPF bone cement created through thermal cross-linking. METHODS PPF was prepared through a two-step process, and BPNSs were prepared via a liquid phase stripping method. BP/PPF was subsequently prepared through thermal cross-linking, and its characteristics were thoroughly analysed. The mechanical properties, cytocompatibility, osteogenic performance, degradation performance, photothermal performance, and in vivo toxicity of BP/PPF were evaluated. RESULTS BP/PPF exhibited low cytotoxicity levels and mechanical properties similar to that of bone, whereas the inclusion of BPNSs promoted preosteoblast adherence, proliferation, and differentiation on the surface of the bone cement. Furthermore, 200 BP/PPF demonstrated superior cytocompatibility and osteogenic effects, leading to the degradation of PPF bone cement and enabling it to possess photothermal properties. When exposed to an 808-nm laser, the temperature of the bone cement increased to 45-55 °C. Furthermore, haematoxylin and eosin-stained sections from the in vivo toxicity test did not display any anomalous tissue changes. CONCLUSION BP/PPF exhibited mechanical properties similar to that of bone: outstanding photothermal properties, cytocompatibility, and osteoinductivity. BP/PPF serves as an effective degradable bone cement and holds great potential in the field of bone regeneration.
Collapse
Affiliation(s)
- Jiahan Chen
- Graduate School of Xinjiang Medical University, Urumqi, Xinjiang, China
- Department of Orthopedics, General Hospital of Xinjiang Military Region, Urumqi, Xinjiang, China
| | - Xiaoxia Huang
- Graduate School of Xinjiang Medical University, Urumqi, Xinjiang, China
- Department of Orthopedics, General Hospital of Xinjiang Military Region, Urumqi, Xinjiang, China
| | - Jianghua Wang
- Department of Pharmacy, General Hospital of Xinjiang Military Region, Urumqi, Xinjiang, China
| | - Wen Chen
- Shihezi University College of Pharmacy, Shihezi, Xinjiang, China
| | - Yong Teng
- Department of Orthopedics, General Hospital of Xinjiang Military Region, Urumqi, Xinjiang, China.
| | - Dongfeng Yin
- Department of Pharmacy, General Hospital of Xinjiang Military Region, Urumqi, Xinjiang, China.
| |
Collapse
|
2
|
Rezaei A, Tilton M, Li Y, Yaszemski MJ, Lu L. Single-level subject-specific finite element model can predict fracture outcomes in three-level spine segments under different loading rates. Comput Biol Med 2021; 137:104833. [PMID: 34534795 DOI: 10.1016/j.compbiomed.2021.104833] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 08/16/2021] [Accepted: 08/31/2021] [Indexed: 11/25/2022]
Abstract
Osteoporosis-related vertebral compression fracture can occur under normal physiological activities. Bone metastasis is another source of vertebral fracture. Different loading rates, either high-energy traumas such as falls or low-energy traumas under normal physiological activities, can result in different fracture outcomes. The aim of the current study was to develop a quantitative computed tomography-based finite element analysis (QCT/FEA) technique for single vertebral bodies to predict fracture strength of three-level spine segments. Developed QCT/FEA technique was also used to characterize vertebral elastic moduli at two loading rates of 5 mm/min, representing a physiologic loading condition, and 12000 mm/min, representing a high-energy trauma. To this end, a cohort of human spine segments divided into three groups of intact, defect, and augmented were mechanically tested to fracture; then, experimental stiffness and fracture strength values were measured. Outcomes of this study showed no significant difference between the elastic modulus equations at the two testing speeds. Areal bone mineral density measured by dual x-ray absorptiometry (DXA/BMD) explained only 53% variability (R2 = 0.53) in fracture strength outcomes. However, QCT/FEA could explain 70% of the variability (R2 = 0.70) in experimentally measured fracture strength values. Adding disk degeneration grading, testing speed, and sex to QCT/FEA-estimated fracture strength values further increased the performance of our statistical model by 14% (adjusted R2 of 0.84 between the prediction and experimental fracture forces). In summary, our results indicated that a single-vertebra model, which is computationally less expensive and more time efficient, is capable of estimating fracture outcomes with acceptable performance (range: 70-84%).
Collapse
Affiliation(s)
- Asghar Rezaei
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Maryam Tilton
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Yong Li
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Michael J Yaszemski
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Lichun Lu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
3
|
Rezaei A, Tilton M, Giambini H, Li Y, Hooke A, Miller Ii AL, Yaszemski MJ, Lu L. Three-dimensional surface strain analyses of simulated defect and augmented spine segments: A biomechanical cadaveric study. J Mech Behav Biomed Mater 2021; 119:104559. [PMID: 33915439 DOI: 10.1016/j.jmbbm.2021.104559] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 04/09/2021] [Accepted: 04/19/2021] [Indexed: 11/19/2022]
Abstract
While several studies have investigated fracture outcomes of intact vertebrae, fracture properties in metastatically-involved and augmented vertebrae are still far from understood. Consequently, this study was aimed to use 3D digital image correlation (3D-DIC) method to investigate the failure properties of spine segments with simulated metastatic lesions, segments augmented with poly(propylene fumarate) (PPF), and compare the outcomes with intact spines. To this end, biomechanical experiments accompanied by 3D-DIC were performed on spine segments consisting of three vertebrae and two intervertebral discs (IVDs) at loading rates of 0.083 mm/s, mimicking a physiological loading condition, and 200 mm/s, mimicking an impact-type loading condition such as a fall or an accident. Full-field surface strain analysis indicated PPF augmentation reduces the superior/inferior strain when compared with the defect specimens; Presence of a defect in the middle vertebra resulted in shear band fracture pattern. Failure of the superior endplates was confirmed in several defect specimens as the superior IVDs were protruding out of defects. The augmenting PPF showed lower superior/inferior surface strain values at the fast speed as compared to the slow speed. The results of our study showed a significant increase in the fracture force from slow to fast speeds (p = 0.0246). The significance of the study was to determine the fracture properties of normal, pathological, and augmented spinal segments under physiologically-relevant loading conditions. Understanding failure properties associated with either defect (i.e., metastasis lesion) or augmented (i.e., post-treatment) spine segments could potentially provide new insights on the outcome prediction and treatment planning. Additionally, this study provides new knowledge on the effect of PPF augmentation in improving fracture properties, potentially decreasing the risk of fracture in osteoporotic and metastatic spines.
Collapse
Affiliation(s)
- Asghar Rezaei
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Maryam Tilton
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Hugo Giambini
- Department of Biomedical Engineering and Chemical Engineering, University of Texas at San Antonio, San Antonio, TX, USA
| | - Yong Li
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Alexander Hooke
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Alan L Miller Ii
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Michael J Yaszemski
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Lichun Lu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
4
|
Rezaei A, Giambini H, Miller Ii AL, Xu H, Xu H, Li Y, Yaszemski MJ, Lu L. CT-based structural analyses of vertebral fractures with polymeric augmentation: A study of cadaveric three-level spine segments. Comput Biol Med 2021; 133:104395. [PMID: 33872967 DOI: 10.1016/j.compbiomed.2021.104395] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2021] [Revised: 04/09/2021] [Accepted: 04/09/2021] [Indexed: 12/27/2022]
Abstract
Pathologic vertebral fractures due to metastasis can occur under normal physiologic activities, leading to pain and neurologic deficit. Prophylactic vertebroplasty is a technique used to augment vertebral strength and reduce the risk of fracture. Currently, no technique is available to objectively assess vertebral fracture risk in metastatically-involved vertebral bodies. The aim of the current study was to develop an image-based computational technique to estimate fracture force outcomes during bending. To this end, mechanical testing was performed on intact, simulated defect, PMMA-augmented, and PPF-augmented 3-level spine segments from both sexes under a compression/flexion-type loading condition. The augmentation performance of poly(methyl methacrylate) (PMMA) and poly(propylene fumarate) (PPF) were also evaluated and compared. Cylindrical defects were created in 3-level spine segments with attached posterior elements and ligaments. Using CT images of each segment, a rigidity analysis technique was developed and used for predicting fracture forces during bending. On average, PPF strengthened the segments by about 630 N, resulting in fracture forces similar to those observed in the intact and PMMA-augmented groups. Female spines fractured at about 1150 N smaller force than did male spines. Rigidity analysis, along with age, explained 66% variability in experimental outcomes. This number increased to 74% when vertebral size and age were added to the rigidity analysis as explanatory variables. Both PPF and PMMA similarly increased fracture strength to the level of intact specimens. The results suggest that PPF can be a suitable candidate for augmentation purposes and rigidity analysis can be a promising predicting tool for vertebral fracture forces.
Collapse
Affiliation(s)
- Asghar Rezaei
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Hugo Giambini
- Department of Biomedical Engineering and Chemical Engineering, University of Texas at San Antonio, San Antonio, TX, USA
| | - Alan L Miller Ii
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Hao Xu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Haocheng Xu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Yong Li
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Michael J Yaszemski
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Lichun Lu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
5
|
Razazpour F, Najafi F, Moshaverinia A, Fatemi SM, Sima S. Synthesis and characterization of a photo-cross-linked bioactive polycaprolactone-based osteoconductive biocomposite. J Biomed Mater Res A 2021; 109:1858-1868. [PMID: 33830598 DOI: 10.1002/jbm.a.37178] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 02/26/2021] [Accepted: 03/24/2021] [Indexed: 01/06/2023]
Abstract
In this study, a light cross-linkable biocomposite scaffold based on a photo-cross-linkable poly (propylene fumarate) (PPF)-co-polycaprolactone (PCL) tri-block copolymer was synthesized and characterized. The developed biodegradable scaffold was further modified with β-tricalcium phosphate (β-TCP) bioceramic for bone tissue engineering applications. The developed biocomposite was characterized using H nuclear magnetic resonance and Fourier transform infrared spectroscopy. Moreover, the bioceramic particle size distribution and morphology were evaluated using Brunauer-Emmett-Teller method, X-ray diffraction, and scanning electron microscopy. The mechanical properties and biodegradation of the scaffolds were also evaluated. Cytotoxicity and mineralization assays were performed to analyze the biocompatibility and bioactivity capacity of the developed biocomposite. The characterization data confirmed the development of a biodegradable and photo-cross-linkable PCL-based biocomposite reinforced with β-TCP bioceramic. In vitro analyses demonstrated the biocompatibility and mineralization potential of the synthesized bioceramic. Altogether, the results of the present study suggest that the photo-cross-linkable PCL-PPF-PCL tri-block copolymer reinforced with β-TCP is a promising biocomposite for bone tissue engineering applications. According to the results, this newly synthesized material has a proper chemical composition for further clinically-relevant studies in tissue engineering.
Collapse
Affiliation(s)
- Fateme Razazpour
- Department of Dental Biomaterials, School of Dentistry/Research Center for Science and Technology in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Farhood Najafi
- Department of Resin and Additives, Institute for Color Science and Technology, Tehran, Iran
| | - Alireza Moshaverinia
- Division of Advanced Prosthodontics, UCLA School of Dentistry, Los Angeles, California, USA
| | - Seyyed Mostafa Fatemi
- Department of Dental Materials, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran.,Medical Laser Research Center, ACER, Tehran, Iran
| | - Shahabi Sima
- Department of Dental Biomaterials, School of Dentistry/Research Center for Science and Technology in Medicine, Tehran University of Medical Sciences, Tehran, Iran.,Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran.,Iranian Dental Biomaterials Association, Tehran, Iran
| |
Collapse
|
6
|
Pang L, Paxton NC, Ren J, Liu F, Zhan H, Woodruff MA, Bo A, Gu Y. Development of Mechanically Enhanced Polycaprolactone Composites by a Functionalized Titanate Nanofiller for Melt Electrowriting in 3D Printing. ACS APPLIED MATERIALS & INTERFACES 2020; 12:47993-48006. [PMID: 33044824 DOI: 10.1021/acsami.0c14831] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Three-dimensional (3D) printing technologies are widely applied in various industries and research fields and are currently the subject of intensive investigation and development. However, high-performance materials that are suitable for 3D printing are still in short supply, which is a major limitation for 3D printing, particularly for biomedical applications. The physicochemical properties of single constituent materials may not be sufficient to meet the needs of modern biotechnology development and production. To enhance the materials' performance and broaden their applications, this work designed and tested a series of titanate nanofiller (nanowire and nanotube)-enhanced polycaprolactone (PCL) composites that were 3D-printable and provided superior mechanical properties. By grafting two different functional groups (phenyl- and thiol-terminated ligands), the nanofiller surface showed improved hydrophobicity, which significantly improved their dispersion in the PCL matrix. After characterizing the surface modification, we evaluated the significance of the homogeneity of the ceramic nanofiller in terms of printability, formability, and mechanical strength. Melt electrowriting additive manufacturing was used to fabricate microfibers of PCL and PCL/nanofiller composites. Improved nanofiller dispersion enabled intact and uniform sample morphology, and in contrast, nanofiller aggregation greatly varied the viscosity during the printing process, which could result in poorly printed structures. Importantly, the modified ceramic/PCL composite delivered enhanced and stable mechanical properties, where its Young's modulus was measured to be 1.67 GPa, which is more than 7 times higher compared to that of pristine PCL (0.22 GPa). Retaining the cell safety properties (comparable to PCL), the concept of enhancing biocompatible polymers with modified nanofillers shows great potential in the field of customized 3D printing for biomedicine.
Collapse
Affiliation(s)
- Le Pang
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Queensland 4001, Australia
| | - Naomi C Paxton
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Queensland 4001, Australia
| | - Jiongyu Ren
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Queensland 4001, Australia
| | - Fan Liu
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Queensland 4001, Australia
- School of Materials Science and Engineering, Wuhan Institute of Technology, Wuhan 430305, China
| | - Haifei Zhan
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Queensland 4001, Australia
| | - Maria A Woodruff
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Queensland 4001, Australia
| | - Arixin Bo
- INM-Leibniz Institute for New Materials, Saarbrücken 66123, Germany
| | - Yuantong Gu
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Queensland 4001, Australia
| |
Collapse
|
7
|
Mushtaq I, Mushtaq I, Akhter Z, Murtaza I, Qamar S, Ayub S, Mirza B, Butt TM, Janjua NK, Shah FU, Zaman F. Engineering electroactive and biocompatible tetra(aniline)-based terpolymers with tunable intrinsic antioxidant properties in vivo. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 108:110456. [DOI: 10.1016/j.msec.2019.110456] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Revised: 10/28/2019] [Accepted: 11/16/2019] [Indexed: 12/27/2022]
|
8
|
Liu X, Miller AL, Xu H, Waletzki BE, Lu L. Injectable Catalyst-Free Poly(Propylene Fumarate) System Cross-Linked by Strain Promoted Alkyne-Azide Cycloaddition Click Chemistry for Spine Defect Filling. Biomacromolecules 2019; 20:3352-3365. [PMID: 31398020 PMCID: PMC9009285 DOI: 10.1021/acs.biomac.9b00133] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
A new PPF-BCN/hyPCL32-N3 injectable system that can be cross-linked by catalyst-free, strain promoted alkyne-azide cycloaddition (SPAAC) click chemistry was developed for tissue engineering applications. The system consisted of two components: PPF-BCN, poly(propylene fumarate) (PPF) functionalized with (1R,8S,9s)-bicyclo[6.1.0]non-4-yn-9-ylmethanol (BCN-OH), and hyPCL32-N3, a hyper-branched 32-arm poly(ε-caprolactone) (PCL) dendrimer functionalized with azide as the cross-linker core. Fast SPAAC click reaction allowed the desired gelation of the system without using any toxic initiator or catalyst. Compared to the conventional injectable formulation, e.g., poly(methyl methacrylate) (PMMA), our PPF-BCN/hyPCL32-N3 (abbreviated as PFCL-Click) injectable system showed enhanced biocompatibility and low heat generation during cross-linking. After reaction, the cross-linked PFCL-Click scaffolds supported excellent proliferation and differentiation of preosteoblast cells on the surface. The PFCL-Click system can be successfully injected into vertebral bodies of rabbit spine and can be monitored by X-ray imaging after incorporating zirconium dioxide (ZrO2) powder. With these unique advantages, this injectable system has promising potential for bone defect repair and other tissue engineering and regenerative medicine applications.
Collapse
Affiliation(s)
- Xifeng Liu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN 55905, USA
| | - A. Lee Miller
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN 55905, USA
| | - Hao Xu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA
| | - Brian E. Waletzki
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN 55905, USA
| | - Lichun Lu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN 55905, USA
| |
Collapse
|
9
|
Jin YZ, Zheng GB, Jang HL, Lee KM, Lee JH. Whitlockite Promotes Bone Healing in Rabbit Ilium Defect Model. J Med Biol Eng 2019. [DOI: 10.1007/s40846-019-00471-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
10
|
Cai Z, Wan Y, Becker ML, Long YZ, Dean D. Poly(propylene fumarate)-based materials: Synthesis, functionalization, properties, device fabrication and biomedical applications. Biomaterials 2019; 208:45-71. [PMID: 30991217 DOI: 10.1016/j.biomaterials.2019.03.038] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 03/04/2019] [Accepted: 03/23/2019] [Indexed: 12/22/2022]
Abstract
Poly(propylene fumarate) (PPF) is a biodegradable polymer that has been investigated extensively over the last three decades. It has led many scientists to synthesize and fabricate a variety of PPF-based materials for biomedical applications due to its controllable mechanical properties, tunable degradation and biocompatibility. This review provides a comprehensive overview of the progress made in improving PPF synthesis, resin formulation, crosslinking, device fabrication and post polymerization modification. Further, we highlight the influence of these parameters on biodegradation, biocompatibility, and their use in a number of regenerative medicine applications, especially bone tissue engineering. In particular, the use of 3D printing techniques for the fabrication of PPF-based scaffolds is extensively reviewed. The recent invention of a ring-opening polymerization method affords precise control of PPF molecular mass, molecular mass distribution (ƉM) and viscosity. Low ƉM facilitates time-certain resorption of 3D printed structures. Novel post-polymerization and post-printing functionalization methods have accelerated the expansion of biomedical applications that utilize PPF-based materials. Finally, we shed light on evolving uses of PPF-based materials for orthopedics/bone tissue engineering and other biomedical applications, including its use as a hydrogel for bioprinting.
Collapse
Affiliation(s)
- Zhongyu Cai
- Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, 117585, Singapore; Department of Chemistry, University of Pittsburgh, Chevron Science Center, 219 Parkman Avenue, Pittsburgh, PA 15260, United States.
| | - Yong Wan
- Collaborative Innovation Center for Nanomaterials, College of Physics, Qingdao University, No. 308 Ningxia Road, Qingdao, 266071, Shandong Province, China
| | - Matthew L Becker
- Department of Polymer Science, The University of Akron, Akron, OH 44325, United States
| | - Yun-Ze Long
- Collaborative Innovation Center for Nanomaterials, College of Physics, Qingdao University, No. 308 Ningxia Road, Qingdao, 266071, Shandong Province, China; Industrial Research Institute of Nonwovens & Technical Textiles, Qingdao University, No. 308 Ningxia Road, Qingdao, 266071, Shandong Province, China.
| | - David Dean
- Department of Plastic & Reconstructive Surgery, The Ohio State University, Columbus, OH 43210, United States.
| |
Collapse
|