1
|
Shibasaki S, Kishino T, Sei Y, Harashima K, Sakata K, Ohnishi H, Watanabe T. Close relationships between neck and upper-back stiffness and transverse cervical artery flow velocity. Eur J Appl Physiol 2024; 124:1925-1931. [PMID: 38280013 DOI: 10.1007/s00421-024-05416-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Accepted: 01/02/2024] [Indexed: 01/29/2024]
Abstract
PURPOSE Neck and upper-back stiffness is encountered in daily life, with symptoms appearing as dullness or aches predominantly in the trapezius muscle (TM). Our previous study demonstrated that TM hardness as measured with a muscle hardness meter correlates well with transverse cervical artery (TCA) flow supplying the TM. Muscle hardness meters, however, cannot measure hardness in the TM alone. Meanwhile, recent advances in ultrasound elastography have enabled the evaluation of localized hardness in targeted tissues. The present study, therefore, aimed to clarify the relationship between TM hardness as measured by elastography and TCA hemodynamics as measured on Doppler sonography, with reference to daily symptoms of upper-back stiffness. METHODS The study population comprised 66 healthy young adults (32 males, 34 females; mean age, 21 ± 1 years). Relationships were evaluated between TM hardness as a negative correlate of strain ratio from elastography and TCA hemodynamics on Doppler sonography. Hemodynamics in the TCA were evaluated according to the frequency of neck and upper-back stiffness. RESULTS TM strain ratio correlated with peak systolic velocity (PSV) in the TCA (r = 0.273, p = 0.036), particularly in symptomatic subjects (r = 0.417, p = 0.022). PSV in the TCA decreased with increasing frequency of daily symptoms (p = 0.045). CONCLUSION TCA hemodynamics correlated with muscle hardness when evaluating localized TM hardness. This relationship and low PSV in the TCA were evident in symptomatic subjects. These results suggest that PSV in the TCA is associated with neck and upper-back stiffness.
Collapse
Affiliation(s)
- Shohei Shibasaki
- Department of Medical Technology, Kyorin University Faculty of Health Sciences, Tokyo, Japan
| | - Tomonori Kishino
- Department of Clinical Engineering, Kyorin University Faculty of Health Sciences, 5-4-1 Shimorenjaku, Mitaka, Tokyo, 181-8612, Japan.
| | - Yoriko Sei
- Department of Medical Technology, Kyorin University Faculty of Health Sciences, Tokyo, Japan
| | - Keiichiro Harashima
- Department of Medical Technology, Kyorin University Faculty of Health Sciences, Tokyo, Japan
| | - Konomi Sakata
- Department of Clinical Engineering, Kyorin University Faculty of Health Sciences, 5-4-1 Shimorenjaku, Mitaka, Tokyo, 181-8612, Japan
| | - Hiroaki Ohnishi
- Department of Laboratory Medicine, Kyorin University Faculty of Medicine, Tokyo, Japan
| | | |
Collapse
|
2
|
Yasuda A, Kubo K. Effects of Static Stretching on the Blood Circulation of Human Tendon In Vivo. TRANSLATIONAL SPORTS MEDICINE 2024; 2024:4413113. [PMID: 38654719 PMCID: PMC11023726 DOI: 10.1155/2024/4413113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 03/28/2024] [Accepted: 04/03/2024] [Indexed: 04/26/2024]
Abstract
The purpose of this study is to compare the effects of 2- and 5 min of static stretching protocols on the changes in blood circulation of tendon (as well as muscle) and heart rate. Twelve healthy males (age: 26.2 ± 9.1 yrs) volunteered for this study. Before, during stretching, during the recovery period (30 min), blood circulation (oxyhemoglobin; oxy, deoxyhemoglobin; deoxy, blood volume; THb, oxygen saturation; StO2) of the Achilles tendon and medial gastrocnemius muscle were measured using red laser lights and near-infrared spectroscopy. In addition, heart rate was measured during the experimental period. For 2- and 5 min of static stretching, oxy, deoxy, THb, and StO2 of the tendon did not change during or after stretching. Regarding muscle blood circulation, oxy and StO2 decreased, and deoxy and THb increased during 2- and 5 min of static stretching but returned immediately upon completion. In addition, heart rate significantly reduced during and after stretching, whereas the changes in blood volume of tendon and muscle during stretching were not associated with those in heart rate (except for the relationship between tendon THb and heart rate in 2 min of static stretching). These results suggest that static stretching showed no change in tendon blood circulation, although muscle blood circulation during stretching was altered. In addition, significant heart rate reduction with static stretching was not associated with changes in tendon and muscle blood circulation.
Collapse
Affiliation(s)
- Ayaka Yasuda
- Department of Life Science (Sports Sciences), The University of Tokyo, Komaba 3-8-1, Meguro-Ku, Tokyo 153-8902, Japan
| | - Keitaro Kubo
- Department of Life Science (Sports Sciences), The University of Tokyo, Komaba 3-8-1, Meguro-Ku, Tokyo 153-8902, Japan
| |
Collapse
|
3
|
Magdalena PG, Bartłomiej B, Robert T, Małgorzata S, Hsing-Kuo W, Sebastian K. Acute fatigue-induced alterations in hamstring muscle properties after repeated Nordic hamstring exercises. Sci Prog 2024; 107:368504241242934. [PMID: 38592327 PMCID: PMC11005512 DOI: 10.1177/00368504241242934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/10/2024]
Abstract
This study aimed to investigate the impact of the Nordic hamstring exercises (NHE) on acute fatigue-induced alterations in the mechanical and morphological properties of hamstring muscles. The second aim was to define the blood flow and perfusion after NHE in recreational active volunteers. Twenty-two individuals volunteered to participate in the study. This study investigated fatigue outcomes: rate of perceived exertion (RPE) scale and average force generated during NHE; mechanical properties (stiffness); morphological properties (thickness, pennation angle, and fascicle length), and vascularity index (VI) of the semitendinosus (ST) and biceps femoris long head (BFLH) at baseline, immediately post-exercise and 1-h post-exercise. The NHE fatigue procedure consisted of six bouts of five repetitions. The results showed an increase in thickness and pennation angle of BFLH and ST immediately post-exercise and a decrease in thickness and pennation angle of BFLH and ST 1-h post-exercise. While the fascicle length of BFLH and ST decreased immediately post-exercise and increased 1-h post-exercise. The VI for two muscles increased immediately post-exercise and after 1-h post-exercise. Moreover, we found a relationship between RPE and average force, that is, as RPE increased during NHE, average force decreased. In conclusion, eccentric NHE exercises significantly and acutely affect BFLH and ST. The NHE fatigue protocol significantly affected the mechanical and morphological properties of BFLH and ST muscles, changing their thickness, fascicle length, pennation angle, and VI.
Collapse
Affiliation(s)
| | - Bogdański Bartłomiej
- Doctoral School, Gdansk University of Physical Education and Sport, Gdańsk, Poland
| | - Trybulski Robert
- ProvitaZory Medical Center, Zory, Poland
- Department of Medical Sciences, The Wojciech Korfanty Upper Silesian Academy, Katowice, Poland
| | - Smoter Małgorzata
- Department of Basic Physiotherapy, Gdansk University of Physical Education and Sport, Gdansk, Poland
| | - Wang Hsing-Kuo
- School and Graduate Institute of Physical Therapy, National Taiwan University, Taipei, Taiwan
- Center of Physical Therapy, National Taiwan University Hospital, Taipei, Taiwan
| | - Klich Sebastian
- Department of Paralympic Sport, Wrocław University of Health and Sport Sciences, Wrocław, Poland
| |
Collapse
|
4
|
Afonso J, Andrade R, Rocha-Rodrigues S, Nakamura FY, Sarmento H, Freitas SR, Silva AF, Laporta L, Abarghoueinejad M, Akyildiz Z, Chen R, Pizarro A, Ramirez-Campillo R, Clemente FM. What We Do Not Know About Stretching in Healthy Athletes: A Scoping Review with Evidence Gap Map from 300 Trials. Sports Med 2024:10.1007/s40279-024-02002-7. [PMID: 38457105 DOI: 10.1007/s40279-024-02002-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/03/2024] [Indexed: 03/09/2024]
Abstract
BACKGROUND Stretching has garnered significant attention in sports sciences, resulting in numerous studies. However, there is no comprehensive overview on investigation of stretching in healthy athletes. OBJECTIVES To perform a systematic scoping review with an evidence gap map of stretching studies in healthy athletes, identify current gaps in the literature, and provide stakeholders with priorities for future research. METHODS Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 and PRISMA-ScR guidelines were followed. We included studies comprising healthy athletes exposed to acute and/or chronic stretching interventions. Six databases were searched (CINAHL, EMBASE, PubMed, Scopus, SPORTDiscus, and Web of Science) until 1 January 2023. The relevant data were narratively synthesized; quantitative data summaries were provided for key data items. An evidence gap map was developed to offer an overview of the existing research and relevant gaps. RESULTS Of ~ 220,000 screened records, we included 300 trials involving 7080 athletes [mostly males (~ 65% versus ~ 20% female, and ~ 15% unreported) under 36 years of age; tiers 2 and 3 of the Participant Classification Framework] across 43 sports. Sports requiring extreme range of motion (e.g., gymnastics) were underrepresented. Most trials assessed the acute effects of stretching, with chronic effects being scrutinized in less than 20% of trials. Chronic interventions averaged 7.4 ± 5.1 weeks and never exceeded 6 months. Most trials (~ 85%) implemented stretching within the warm-up, with other application timings (e.g., post-exercise) being under-researched. Most trials examined static active stretching (62.3%), followed by dynamic stretching (38.3%) and proprioceptive neuromuscular facilitation (PNF) stretching (12.0%), with scarce research on alternative methods (e.g., ballistic stretching). Comparators were mostly limited to passive controls, with ~ 25% of trials including active controls (e.g., strength training). The lower limbs were primarily targeted by interventions (~ 75%). Reporting of dose was heterogeneous in style (e.g., 10 repetitions versus 10 s for dynamic stretching) and completeness of information (i.e., with disparities in the comprehensiveness of the provided information). Most trials (~ 90%) reported performance-related outcomes (mainly strength/power and range of motion); sport-specific outcomes were collected in less than 15% of trials. Biomechanical, physiological, and neural/psychological outcomes were assessed sparsely and heterogeneously; only five trials investigated injury-related outcomes. CONCLUSIONS There is room for improvement, with many areas of research on stretching being underexplored and others currently too heterogeneous for reliable comparisons between studies. There is limited representation of elite-level athletes (~ 5% tier 4 and no tier 5) and underpowered sample sizes (≤ 20 participants). Research was biased toward adult male athletes of sports not requiring extreme ranges of motion, and mostly assessed the acute effects of static active stretching and dynamic stretching during the warm-up. Dose-response relationships remain largely underexplored. Outcomes were mostly limited to general performance testing. Injury prevention and other effects of stretching remain poorly investigated. These relevant research gaps should be prioritized by funding policies. REGISTRATION OSF project ( https://osf.io/6auyj/ ) and registration ( https://osf.io/gu8ya ).
Collapse
Affiliation(s)
- José Afonso
- Faculty of Sport, Centre of Research, Education, Innovation, and Intervention in Sport (CIFI2D), University of Porto, Porto, Portugal.
| | - Renato Andrade
- Clínica Espregueira-FIFA Medical Centre of Excellence, Porto, Portugal
- Dom Henrique Research Centre, Porto, Portugal
- Porto Biomechanics Laboratory (LABIOMEP), University of Porto, Porto, Portugal
| | - Sílvia Rocha-Rodrigues
- Escola Superior de Desporto e Lazer, Instituto Politécnico de Viana do Castelo, Rua Escola Industrial e Comercial de Nun'Alvares, 4900-347, Viana do Castelo, Portugal
- Tumour and Microenvironment Interactions Group, INEB-Institute of Biomedical Engineering, i3S-Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 4200-153, Porto, Portugal
- Sport Physical Activity and Health Research & Innovation Center, 4900-347, Viana do Castelo, Portugal
| | - Fábio Yuzo Nakamura
- Research Center in Sports Sciences, Health Sciences and Human Development (CIDESD), University of Maia, Maia, Portugal
| | - Hugo Sarmento
- University of Coimbra, Research Unit for Sport and Physical Activity (CIDAF), Faculty of Sport Sciences and Physical Education, Coimbra, Portugal
| | - Sandro R Freitas
- Laboratório de Função Neuromuscular, Faculdade de Motricidade Humana, Universidade de Lisboa, Cruz Quebrada, Portugal
| | - Ana Filipa Silva
- Escola Superior de Desporto e Lazer, Instituto Politécnico de Viana do Castelo, Rua Escola Industrial e Comercial de Nun'Alvares, 4900-347, Viana do Castelo, Portugal
- Sport Physical Activity and Health Research & Innovation Center, 4900-347, Viana do Castelo, Portugal
| | - Lorenzo Laporta
- Núcleo de Estudos em Performance Analysis Esportiva (NEPAE/UFSM), Universidade Federal de Santa Maria, Avenida Roraima, nº 1000, Cidade Universitária, Bairro Camobi, Santa Maria, RS, CEP: 97105-900, Brazil
| | | | - Zeki Akyildiz
- Sports Science Faculty, Department of Coaching Education, Afyon Kocatepe University, Afyonkarahisar, Turkey
| | - Rongzhi Chen
- Faculty of Sport, Centre of Research, Education, Innovation, and Intervention in Sport (CIFI2D), University of Porto, Porto, Portugal
| | - Andreia Pizarro
- Faculty of Sport, Research Center in Physical Activity, Health and Leisure (CIAFEL), University of Porto, Porto, Portugal
- Laboratory for Integrative and Translational Research in Population Health (ITR), Rua das Taipas, 135, 4050-600, Porto, Portugal
| | - Rodrigo Ramirez-Campillo
- Exercise and Rehabilitation Sciences Institute, School of Physical Therapy. Faculty of Rehabilitation Sciences, Universidad Andres Bello, 7591538, Santiago, Chile
| | - Filipe Manuel Clemente
- Escola Superior de Desporto e Lazer, Instituto Politécnico de Viana do Castelo, Rua Escola Industrial e Comercial de Nun'Alvares, 4900-347, Viana do Castelo, Portugal
- Sport Physical Activity and Health Research & Innovation Center, 4900-347, Viana do Castelo, Portugal
- Gdańsk University of Physical Education and Sport, 80-336, Gdańsk, Poland
| |
Collapse
|
5
|
Miller T, Bello UM, Tsang CSL, Winser SJ, Ying MTC, Pang MYC. Using ultrasound elastography to assess non-invasive, non-pharmacological interventions for musculoskeletal stiffness: a systematic review and meta-analysis. Disabil Rehabil 2023:1-15. [PMID: 37668241 DOI: 10.1080/09638288.2023.2252744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 08/13/2023] [Accepted: 08/22/2023] [Indexed: 09/06/2023]
Abstract
PURPOSE To evaluate the current evidence regarding the use of ultrasound elastography for assessing non-invasive, non-pharmacological interventions for eliciting changes in musculoskeletal stiffness. METHODS A systematic search of MEDLINE, CINAHL, EMBASE, and Web of Science databases was performed in accordance with Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines. Information on measurement and intervention procedures was extracted. Bias was assessed using Cochrane Risk of Bias or Risk of Bias In Non-randomised Studies of Interventions (ROBINS-I) tools for studies with true or quasi-experimental designs, respectively. Analyses were conducted for adequately powered subgroups based on intervention type, measurement site, and population assessed. RESULTS Twenty-one studies were included in the review. Overall risk of bias was low for true experimental studies and moderate for quasi-experimental studies. Subgroup analyses indicated a large overall effect for interventions involving manual physiotherapy and taping/splinting for reducing masseter muscle stiffness in patients with masticatory muscle disorders (g = 1.488, 95% CI = 0.320-2.655, p = 0.013). Analyses for other intervention types and patient groups were underpowered. CONCLUSION Ultrasound elastography demonstrates clinical applicability for assessing non-invasive, non-pharmacological interventions for musculoskeletal stiffness. However, the comparative efficacy of these interventions for modulating tissue stiffness remains inconclusive.
Collapse
Affiliation(s)
- Tiev Miller
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong, China
- International Collaboration on Repair Discoveries, Faculty of Medicine, University of British Columbia, Vancouver, Canada
- Division of Physical Medicine and Rehabilitation, Department of Medicine, University of British Columbia, Vancouver, Canada
| | - Umar M Bello
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong, China
- Department of Physiotherapy and Paramedicine, Glasgow Caledonian University, Glasgow, United Kingdom
| | - Charlotte S L Tsang
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong, China
| | - Stanley J Winser
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong, China
| | - Michael T C Ying
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Marco Y C Pang
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong, China
| |
Collapse
|
6
|
Sucharit W, Roberts N, Eungpinichpong W, Hunsawong T, Chatchawan U. Standardised 25-Step Traditional Thai Massage (TTM) Protocol for Treating Office Syndrome (OS). INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:6159. [PMID: 37372746 DOI: 10.3390/ijerph20126159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 05/31/2023] [Accepted: 06/09/2023] [Indexed: 06/29/2023]
Abstract
Traditional Thai massage (TTM) is a unique form of whole body massage practiced to promote health and well-being in Thailand since ancient times. The goal of the present study was to create a standardised TTM protocol to treat office syndrome (OS) diagnosed based on the identification of the palpation of at least one so-called myofascial trigger point (MTrP) in the upper trapezius muscle. The new 90 min TTM protocol, which was developed following appropriate review of the literature and in consultation with relevant experts, has 25 distinct steps (20 pressing steps, 2 artery occlusion steps, and 3 stretching steps). Eleven TTM therapists treated three patients each using the new 90 min TTM protocol. All of the therapists reported scores greater than 80% in respect to their satisfaction and confidence to deliver the protocol, and all of the patients gave the treatment a satisfaction score of greater than 80%. The treatment produced a significant reduction in pain intensity measured on a Visual Analogue Scale (VAS), with minimum and maximum values of 0 and 10 cm, of 2.33 cm (95% CI (1.76, 2.89 cm), p < 0.001) and significant increase in pain pressure threshold (PPT) of 0.37 kg/cm2 (95% CI (0.10, 0.64 kg/cm2), p < 0.05). The protocol was revised based on the feedback and the results obtained, and the new standardised TTM protocol will be applied in a randomised control trial (RCT) to compare the efficacy of TTM and conventional physical therapy (PT) for treating OS.
Collapse
Affiliation(s)
- Wiraphong Sucharit
- Research Center in Back, Neck, Other Joint Pain and Human Performance (BNOJPH), School of Physical Therapy, Faculty of Associated Medical Sciences (AMS), Khon Kaen University (KKU), Khon Kaen 40002, Thailand
| | - Neil Roberts
- Centre for Reproductive Health (CRH), School of Clinical Sciences, The Queen's Medical Research Institute (QMRI), University of Edinburgh, Edinburgh EH16 4TJ, UK
| | - Wichai Eungpinichpong
- Research Center in Back, Neck, Other Joint Pain and Human Performance (BNOJPH), School of Physical Therapy, Faculty of Associated Medical Sciences (AMS), Khon Kaen University (KKU), Khon Kaen 40002, Thailand
| | - Torkamol Hunsawong
- Research Center in Back, Neck, Other Joint Pain and Human Performance (BNOJPH), School of Physical Therapy, Faculty of Associated Medical Sciences (AMS), Khon Kaen University (KKU), Khon Kaen 40002, Thailand
| | - Uraiwan Chatchawan
- Research Center in Back, Neck, Other Joint Pain and Human Performance (BNOJPH), School of Physical Therapy, Faculty of Associated Medical Sciences (AMS), Khon Kaen University (KKU), Khon Kaen 40002, Thailand
| |
Collapse
|
7
|
Kawama R, Hojo T, Wakahara T. Acute changes in passive stiffness of the individual hamstring muscles induced by resistance exercise: effects of muscle length and exercise duration. Eur J Appl Physiol 2023; 123:655-666. [PMID: 36394605 DOI: 10.1007/s00421-022-05092-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 11/09/2022] [Indexed: 11/18/2022]
Abstract
PURPOSE A previous study revealed that resistance exercise with eccentric contraction and a wide range of motion (ROM) can acutely decrease muscle stiffness of a specific muscle. To explore further approaches to decrease the stiffness, we examined the acute changes in passive stiffness of the individual hamstring muscles after eccentric-only resistance exercise with different combinations of muscle lengths and exercise durations. METHODS Thirteen healthy young male participants performed three sessions of eccentric-only exercises that comprised stiff-leg deadlift with different muscle lengths and exercise durations (duration per repetition × the total number of repetitions) on separate days as follows: (1) short muscle lengths with a short duration (SS); (2) long muscle lengths with a short duration (LS); and (3) long muscle lengths with a long duration (LL). Maximal joint ROM, passive torque, shear modulus of each hamstring muscle, and maximal isometric torque of knee flexion were measured before, and at 3, 30, and 60 min after each session. RESULTS The shear modulus of the semimembranosus was significantly lower at 3 min post-exercise (129.8 ± 22.7 kPa) than at pre-exercise (140.5 ± 19.1 kPa, p < 0.01) in LL, but not in SS or LS. No significant differences were observed in the shear moduli of the biceps femoris long head or semitendinosus between pre-exercise and 3 min post-exercise in any session. CONCLUSION The combination of long muscle lengths and a long duration during eccentric-only resistance exercise is important to immediately decrease the stiffness (shear modulus) of a specific muscle.
Collapse
Affiliation(s)
- Raki Kawama
- Graduate School of Health and Sports Science, Doshisha University, Kyoto, Japan
- Research Fellow of Japan Society for the Promotion of Science, Tokyo, Japan
| | - Tatsuya Hojo
- Graduate School of Health and Sports Science, Doshisha University, Kyoto, Japan
- Faculty of Health and Sports Science, Doshisha University, Kyoto, Japan
| | - Taku Wakahara
- Faculty of Health and Sports Science, Doshisha University, Kyoto, Japan.
- Human Performance Laboratory, Waseda University, Saitama, Japan.
| |
Collapse
|
8
|
Karacabey BN, Bayramoğlu Z, Coşkun O, Sarı ZNA, Özkan MU, Yıldız EP, Aydınlı N, Çalışkan M. Shear Wave Elastography in Patients with Spinal Muscular Atrophy Types 2 and 3. Neuropediatrics 2023. [PMID: 36706786 DOI: 10.1055/a-2021-0403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
INTRODUCTION This study aimed to investigate selective muscle involvement by shear wave elastography (SWE) in patients with spinal muscular atrophy (SMA) types 2 and 3 and to compare SWE values with magnetic resonance imaging (MRI) in demonstrating muscle involvement. METHODS Seventeen patients with SMA types 2 and3 were included in the study. SWE was used to evaluate stiffness of the upper and lower extremities and paraspinal muscles. Involvement of the paraspinal muscles was evaluated using 1.5-T MRI. RESULTS Among the upper extremity muscles, SWE values were the highest for the triceps brachii; however, no significant difference was noted (p = 0.23). In post hoc analysis, a significant difference was observed between triceps brachii and biceps brachii (p = 0.003). Patients with a longer disease duration have the highest SWE values for the triceps brachii (r = 0.67, p = 0.003). Among the lower extremity muscles, SWE values for the iliopsoas were significantly higher than the gluteus maximus (p < 0.001). A positive correlation was found between SWE values and MRI scores of paraspinal muscles (r = 0.49, p = 0.045; r = 0.67, p = 0.003). CONCLUSION This is the first study to report muscle involvement assessed by SWE in patients with SMA types 2 and 3. Our findings are similar to the presence of selective muscle involvement demonstrated in previous studies, and also SWE and MRI values were similar. SWE is an alternative noninvasive practical method that can be used to demonstrate muscle involvement in patients with SMA, to understand the pathogenesis of segmental involvement, and to guide future treatments or to monitor the effectiveness of existing new treatment options.
Collapse
Affiliation(s)
- Burçin Nazlı Karacabey
- Department of Pediatric Neurology, Istanbul Faculty of Medicine, Istanbul University, Fatih, Istanbul, Turkey
| | - Zuhal Bayramoğlu
- Department of Radiology, Istanbul Faculty of Medicine, Istanbul University, Fatih, Istanbul, Turkey
| | - Orhan Coşkun
- Department of Pediatric Neurology, Istanbul Faculty of Medicine, Istanbul University, Fatih, Istanbul, Turkey
| | - Zeynep Nur Akyol Sarı
- Department of Radiology, Istanbul Faculty of Medicine, Istanbul University, Fatih, Istanbul, Turkey
| | - Melis Ulak Özkan
- Institute of Child Health, Istanbul University, Fatih, Istanbul, Turkey
| | - Edibe Pembegül Yıldız
- Department of Pediatric Neurology, Istanbul Faculty of Medicine, Istanbul University, Fatih, Istanbul, Turkey.,Department of Radiology, Istanbul Faculty of Medicine, Istanbul University, Fatih, Istanbul, Turkey.,Institute of Child Health, Istanbul University, Fatih, Istanbul, Turkey
| | - Nur Aydınlı
- Department of Pediatric Neurology, Istanbul Faculty of Medicine, Istanbul University, Fatih, Istanbul, Turkey
| | - Mine Çalışkan
- Institute of Child Health, Istanbul University, Fatih, Istanbul, Turkey
| |
Collapse
|
9
|
Nonnenmacher CH, Nunes I, de Moura BM, Diefenthaeler F, Lima KMME. Does static stretching change uniformly the quadriceps elasticity in physically actives subjects? J Ultrasound 2022; 25:915-921. [PMID: 35412126 PMCID: PMC9705688 DOI: 10.1007/s40477-021-00649-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Accepted: 12/11/2021] [Indexed: 10/18/2022] Open
Abstract
PURPOSE Verify the acute responses of static stretching (SS) on the rectus femoris (RF), vastus medialis (VM), and vastus lateralis (VL) elasticity and knee/hip range of motion (ROM). Additionally, to investigate if there are consistency among quadriceps muscle elasticity after SS. METHODS Acute effect of SS on pre-post-intervention design. Thirtheen healthy participants (both genders) proposed for a pre-post experimental design. RF, VM, and VL elasticity (strain ratio, SR) was evaluated bilaterally by ultrasound with quasi-static elastography. Higher SR values refer to more rigid tissues. A SS protocol of 3 series of 30 s was applied at right lower limb. The left lower limb was considered as control group. Also, photogrammetry evaluated the knee/hip ROM. RESULTS For SR muscle comparisons, VM was lower (less stiff) than VL and RF at pre- and post-SS. For time comparisons, no differences were observed for SR and ROM at pre- and post-SS. However, the effect size of the quadriceps SR at SS lower limb was higher than control. CONCLUSION Acute effects of SS did not change the quadriceps SR or knee/hip ROM in healthy and active subjects. Non-uniform quadriceps SR are observed (VM < VL and RF) independently of SS. Future studies should consider different protocols, muscles, and populations.
Collapse
Affiliation(s)
- Carolina Holz Nonnenmacher
- Physiotherapy Course, Department of Health Sciences, Federal University of Santa Catarina, Governador Jorge Lacerda, 3201, Araranguá, Santa Catarina, 88906-072, Brazil.
| | - Iohana Nunes
- Post-Graduate Program in Rehabilitation Sciences, Federal University of Santa Catarina, Araranguá, 88906-072, Brazil
| | - Bruno Monteiro de Moura
- Biomechanics Laboratory, Department of Physical Education, Sports Center, Federal University of Santa Catarina, Florianópolis, 88040-900, Brazil
| | - Fernando Diefenthaeler
- Biomechanics Laboratory, Department of Physical Education, Sports Center, Federal University of Santa Catarina, Florianópolis, 88040-900, Brazil
| | - Kelly Mônica Marinho E Lima
- Physiotherapy Course, Department of Health Sciences, Federal University of Santa Catarina, Governador Jorge Lacerda, 3201, Araranguá, Santa Catarina, 88906-072, Brazil
| |
Collapse
|
10
|
Lall PS, Alsubiheen AM, Aldaihan MM, Lee H. Differences in Medial and Lateral Gastrocnemius Stiffness after Exercise-Induced Muscle Fatigue. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph192113891. [PMID: 36360770 PMCID: PMC9656849 DOI: 10.3390/ijerph192113891] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 10/18/2022] [Accepted: 10/24/2022] [Indexed: 06/10/2023]
Abstract
Muscles are affected at the cellular level by exercised-induced fatigue, inducing changes in their stiffness. Examining muscle stiffness can improve the knowledge of various pathologic conditions, such as pain and injury. The objective of this study was to examine the stiffness of the medial gastrocnemius (MG) muscle and the lateral gastrocnemius (LG) muscle to determine the changes in stiffness, and to assess the differences in the stiffness between the MG and the LG, as affected by muscle fatigue measured using shear wave elastography (SWE) and a MyotonPRO after inducing muscle fatigue. A total of 35 healthy young adults participated in the study. The stiffness of the MG and the LG were assessed before and after a muscle fatigue protocol (MFP), which included three sets of 50 eccentric contractions of the calf muscles of the dominant leg, at rest, and at maximum voluntary contraction (MVC). The measurements were taken with SWE and the MyotonPRO simultaneously. Compared to baseline, the resting stiffness of the MG and the LG significantly increased immediately, 24 h, and 48 h after muscle fatigue (p < 0.05); however, during MVC, the stiffness of the MG decreased (p < 0.05) and that of the LG showed no change (p > 0.05). When the stiffness of the MG and the LG were compared before and after the MFP, changes in the stiffness of the MG were significantly greater than those in the LG (p < 0.05). This signifies that the MG was more affected by the exercise-induced muscle fatigue than was the LG. The assessment of musculoskeletal tissue and its characteristics, before and after eccentric exercise, is crucial in the prevention of overuse injuries associated with repeated exposure to both low and high levels of force.
Collapse
Affiliation(s)
- Prarthana Sanya Lall
- Graduate School, Department of Physical Therapy, College of Health Science, Gachon University, Incheon 21936, Korea
| | - Abdulrahman M. Alsubiheen
- Department of Rehabilitation Sciences, College of Applied Medical Sciences, King Saud University, Riyadh 11451, Saudi Arabia
| | - Mishal M. Aldaihan
- Department of Rehabilitation Sciences, College of Applied Medical Sciences, King Saud University, Riyadh 11451, Saudi Arabia
| | - Hanuel Lee
- Graduate School, Department of Physical Therapy, College of Health Science, Gachon University, Incheon 21936, Korea
- Department of Physical Therapy, College of Health Science, Gachon University, Incheon 21936, Korea
| |
Collapse
|
11
|
Lo YH, Chou WY, Yen KT, Wu CF, Yang YJ. Improvement of lower-extremity stability by rotational leg press training. Gait Posture 2022; 98:337-342. [PMID: 36274471 DOI: 10.1016/j.gaitpost.2022.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 09/13/2022] [Accepted: 10/08/2022] [Indexed: 02/02/2023]
Abstract
BACKGROUNDS Previous reports revealed that balance and stability are essential for human physical activity. The present study aimed to evaluate the comparative outcome of a novel beginning movement load training (BMLT) versus conventional leg press training in terms of improvement of lower-extremity stability. RESEARCH QUESTION Does the leg press training improve the stability of lower extremities? METHODS Twenty adult, asymptomatic and active amateur basketball players were enrolled in this study and randomized in equal numbers into a BMLT group (study group) and a conventional leg press training group (control group). RESULTS The results after eight-week course of training showed that conventional leg press training had an opposite effect on dynamic stability in the left leg (p = 0.015) and backward movement of the right leg (p = 0.038). The athletes in the study group revealed superior dynamic stability maintenance in both legs backwards (p = 0.001), the left leg (p = 0.013), the right leg backwards (p = 0.022) and overall stability (p = 0.002). SIGNIFICANCE The study group showed better postural stability in terms of the medial/lateral index (p = 0.017), and the athletes in the control group exhibited a significant inability to maintain postural stability in the medial/lateral aspect after the training (p = 0.016). Rotational BMLT lower-extremity press training yielded superior enhancement of dynamic stability and maintenance of center of gravity and postural stability.
Collapse
Affiliation(s)
- Yu-Hsun Lo
- Sports Medicine Center, Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital, No.123, Dapi Rd., Niaosong Dist., Kaohsiung City 833, Taiwan; Center of Comprehensive Sports Medicine, Chang Gung Memorial Hospital, No.123, Dinghu Rd., Guishan Dist., Taoyuan County, 333, Taiwan
| | - Wen-Yi Chou
- Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, No.123, Dapi Rd., Niaosong Dist., Kaohsiung City 833, Taiwan; Sports Medicine Center, Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital, No.123, Dapi Rd., Niaosong Dist., Kaohsiung City 833, Taiwan; Center of Comprehensive Sports Medicine, Chang Gung Memorial Hospital, No.123, Dinghu Rd., Guishan Dist., Taoyuan County, 333, Taiwan; Department of Sports, Health and Leisure and Graduate Institute of Sports, Health and Leisure, Cheng Shiu University, No.840, Chengqing Rd., Niaosong Dist., Kaohsiung City 833, Taiwan.
| | - Ke-Tien Yen
- Department of Sports, Health and Leisure and Graduate Institute of Sports, Health and Leisure, Cheng Shiu University, No.840, Chengqing Rd., Niaosong Dist., Kaohsiung City 833, Taiwan
| | - Chia-Feng Wu
- Sports Medicine Center, Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital, No.123, Dapi Rd., Niaosong Dist., Kaohsiung City 833, Taiwan
| | - Ya-Ju Yang
- Sports Medicine Center, Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital, No.123, Dapi Rd., Niaosong Dist., Kaohsiung City 833, Taiwan
| |
Collapse
|
12
|
Ustabaşıoğlu FE, Ağırdemir FE, Ustabaşıoğlu F, Sunal BS. Acute effect of resistance exercise at different velocities on stiffness and vascularity of the biceps brachii muscle: a preliminary study. Acta Radiol 2022; 64:1500-1507. [PMID: 36112819 DOI: 10.1177/02841851221125380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background Resistance exercise can be defined as the percentage of maximal strength (%1 repetition maximum) used for a particular exercise. Shear wave elastography (SWE) is a robust and novelty imaging technique that provides information regarding tissue stiffness. Superb microvascular imaging (SMI) is a non-irradiating technique that can provide quantitative measurement of muscle blood flow non-invasively. Purpose To compare the acute effects of low- and high-velocity resistance exercise on stiffness and blood flow in the biceps brachii muscle (BBM) using SWE and SMI. Material and Methods This prospective study included 60 healthy men (mean age=28.9 years; age range=26–34 years). BBM stiffness was measured by using SWE at rest, after low- and high-velocity resistance exercise, and muscle blood flow was also evaluated by SMI. Resistance exercise was performed using a dumbbell with a mass adjusted to 70%–80% of one-repetition maximum. Results The stiffness values increased significantly from resting to high- and low-velocity resistance exercises. There was no significant difference between the elastography values of the BBM after the high- and low-velocity resistance exercise. The blood flow increased significantly from resting to high- and low-velocity resistance exercises. Blood flow increase after low-velocity exercise was significantly higher compared to high-velocity exercise. Conclusion While muscle stiffness parameters and blood flow significantly increased from resting after both high- and low-velocity resistance exercises, blood flow significantly increased after low-velocity exercise compared to high-velocity exercise. This can mean that metabolic stress, an important trigger for muscle development, is more likely to occur in low-velocity exercise.
Collapse
Affiliation(s)
| | - Fatma Ebru Ağırdemir
- Department of Sports Medicine, Edirne Sultan 1st Murat State Hospital, Edirne, Turkey
| | - Fatma Ustabaşıoğlu
- Department of Physical Medicine and Rehabilitation, Edirne Sultan 1st Murat State Hospital, Edirne, Turkey
| | - Baran Serdar Sunal
- Department of Radiology, Trakya University Faculty of Medicine, Edirne, Turkey
| |
Collapse
|
13
|
Mahmoud WS, Osailan A, Elnaggar RK, Alhailiy AB. Radiological and clinical outcomes of concurrent hamstring stretching with quadriceps strengthening in patients with knee osteoarthritis: A randomized clinical trial. ISOKINET EXERC SCI 2022. [DOI: 10.3233/ies-220056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND: Hamstring shortening altered joint reaction forces during activities of daily living (ADL), causing knee pain. Moreover, weak quadriceps may negatively distribute the compressive and shear forces at the knee joint. PURPOSE: The study examined the effect of adding hamstring stretching to quadriceps strengthening exercises on joint space narrowing (JSN), medial joint space width (mJSW), and physical abilities in patients with knee osteoarthritis (KOA). METHODS: A total of 42 osteoarthritis patients, aged from 50 to 65 years, were randomized and assigned into 2 groups: the study and the control groups. Quadriceps strengthening exercises were given to both groups, while static hamstring stretching was applied to only the study group. Patients of both groups were screened with a weight-bearing x-ray beam to investigate the JSN, mJSW, and functional abilities measured in the WOMAC scale. The Outcomes were evaluated at the baseline and immediately after 6 weeks of treatment. RESULTS: The mJSW improved in the study group (p< 0.001) compared to the control group (p= 0.07). The OARSI JSN was enhanced significantly in both groups, but in favor of the study group (p< 0.001) over the control group (p= 0.046). Both MVIC and total score of WOMAC were significantly improved in both groups (p< 0.001). CONCLUSION: Adding static hamstring stretching to quadriceps strengthening exercises provided a substantial effect on mJSW, JSN, and functional abilities in KOA patients.
Collapse
Affiliation(s)
- Waleed S. Mahmoud
- Department of Physical Therapy and Health Rehabilitation, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Saudi Arabia
- Department of Basic Sciences, Faculty of Physical Therapy, Cairo University, Giza, Egypt
| | - Ahmed Osailan
- Department of Physical Therapy and Health Rehabilitation, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Saudi Arabia
| | - Ragab K. Elnaggar
- Department of Physical Therapy and Health Rehabilitation, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Saudi Arabia
- Department of Physical Therapy for Pediatrics, Faculty of Physical Therapy, Cairo University, Giza, Egypt
| | - Ali B. Alhailiy
- Department of Radiology and Medical Imaging, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Saudi Arabia
| |
Collapse
|
14
|
Kawama R, Yanase K, Hojo T, Wakahara T. Acute changes in passive stiffness of the individual hamstring muscles induced by resistance exercise: effects of contraction mode and range of motion. Eur J Appl Physiol 2022; 122:2071-2083. [PMID: 35699758 DOI: 10.1007/s00421-022-04976-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Accepted: 05/27/2022] [Indexed: 11/27/2022]
Abstract
PURPOSE Recent studies raise an interesting possibility that resistance exercise also decreases passive muscle stiffness, as does stretching exercise. However, little is known about how program variables of resistance exercise acutely influence muscle stiffness. We aimed to examine the acute changes in passive stiffness of the individual hamstring muscles after resistance exercises using different combinations of contraction modes and ranges of motion (ROMs). METHODS Thirteen healthy young male participants performed three sessions of resistance exercises that comprised stiff-leg deadlift with different contraction modes and exercise ROMs on separate days as follows: (1) eccentric contractions with a wide exercise ROM (EW); (2) eccentric contractions with a narrow exercise ROM (EN); and (3) concentric contractions with a wide exercise ROM (CW). Maximal joint ROM, passive torque, shear modulus of the individual hamstring muscles, and maximal isometric torque of knee flexion were measured before and 3 min, 30 min, and 60 min after completing each session. RESULTS The shear modulus of the semimembranosus was significantly lower at 3 min post-exercise (121.8 ± 16.0 kPa) than at pre-exercise (129.0 ± 18.9 kPa, p = 0.021, r = 0.45) in EW, but not in EN or CW. There were no significant changes in the shear moduli of the biceps femoris long head or the semitendinosus at any timepoint in any exercise protocols. CONCLUSIONS The present results suggest that the combination of eccentric contraction and wide ROM during resistance exercise has the potential to acutely decrease passive stiffness (shear modulus) of a specific muscle.
Collapse
Affiliation(s)
- Raki Kawama
- Graduate School of Health and Sports Science, Doshisha University, Kyoto, Japan.,Research Fellow of Japan Society for the Promotion of Science, Tokyo, Japan
| | - Ko Yanase
- Faculty of Health and Sports Science, Doshisha University, Kyoto, Japan.,Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Tatsuya Hojo
- Graduate School of Health and Sports Science, Doshisha University, Kyoto, Japan.,Faculty of Health and Sports Science, Doshisha University, Kyoto, Japan
| | - Taku Wakahara
- Faculty of Health and Sports Science, Doshisha University, Kyoto, Japan. .,Human Performance Laboratory, Waseda University, Saitama, Japan.
| |
Collapse
|
15
|
Stone BL, Ashley JD, Skinner RM, Polanco JP, Walters MT, Schilling BK, Kellawan JM. Effects of a Short-Term Heat Acclimation Protocol in Elite Amateur Boxers. J Strength Cond Res 2022; 36:1966-1971. [PMID: 35510889 DOI: 10.1519/jsc.0000000000004233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
ABSTRACT Stone, BL, Ashley, JD, Skinner, RM, Polanco, JP, Walters, MT, Schilling, BK, and Kellawan, JM. Effects of a short-term heat acclimation protocol in elite amateur boxers. J Strength Cond Res XX(X): 000-000, 2022-Boxing requires proficient technical and tactical skills coupled with high levels of physiological capacity. Although heat and humidity negatively affect acute exercise performance, short-term exercise training in hot and humid environments can lead to physiological adaptations that enhance exercise performance in both hot and thermoneutral conditions. In highly trained endurance athletes, exercise-induced acclimation can occur in as little as 5 days (known as short-term heat acclimation [STHA]). However, the impact of a 5-day heat acclimation (5-DayHA) in combat athletes, such as elite amateur boxers, is unknown. The aim of the present investigation was to determine whether a 5-DayHA improves aerobic performance in a thermoneutral environment and causes positive physiological adaptations in elite boxers. Seven elite amateur boxers underwent a 5-DayHA protocol, consisting of 60-minute exercise sessions in an environmental chamber at 32 °C and 70% relative humidity. Repeat sprint test (RST) evaluated aerobic performance in a thermoneutral environment 24 hours before and after the 5-DayHA. Presession and postsession hydration status (urine specific gravity) and body mass were assessed. After a 5-DayHA period, boxers significantly improved RST performance (13 ± 7 to 19 ± 7 sprints, d = 0.92, p = 0.03) but not pre-exercise hydration status (1.02 ± 0.01 to 1.01 ± 0.01, d = 0.82, p = 0.07). Therefore, these findings suggest 5-DayHA enhances aerobic performance in elite-level amateur boxers and may provide a viable training option for elite combat athletes.
Collapse
Affiliation(s)
- Brandon L Stone
- Human Circulation Research Laboratory, Department of Health and Exercise Science, University of Oklahoma, Norman, Oklahoma.,Sport Sciences, U.S. Olympic Committee, Colorado Springs, Colorado.,Applied Research, Toronto Blue Jays Baseball Club, Dunedin, Florida
| | - John D Ashley
- Human Circulation Research Laboratory, Department of Health and Exercise Science, University of Oklahoma, Norman, Oklahoma
| | - Robert M Skinner
- Sport Sciences, U.S. Olympic Committee, Colorado Springs, Colorado
| | - Jose P Polanco
- Sport Sciences, U.S. Olympic Committee, Colorado Springs, Colorado
| | - Mason T Walters
- Sport Sciences, U.S. Olympic Committee, Colorado Springs, Colorado.,Department of Health Sciences, University of Colorado at Colorado Springs, Colorado Springs, Colorado; and
| | - Brian K Schilling
- Kinesiology and Nutrition Sciences, University of Nevada-Las Vegas, Las Vegas, Nevada
| | - J M Kellawan
- Human Circulation Research Laboratory, Department of Health and Exercise Science, University of Oklahoma, Norman, Oklahoma
| |
Collapse
|
16
|
Matsuda Y, Nakabayashi M, Suzuki T, Zhang S, Ichinose M, Ono Y. Evaluation of Local Skeletal Muscle Blood Flow in Manipulative Therapy by Diffuse Correlation Spectroscopy. Front Bioeng Biotechnol 2022; 9:800051. [PMID: 35087803 PMCID: PMC8786806 DOI: 10.3389/fbioe.2021.800051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 12/17/2021] [Indexed: 11/13/2022] Open
Abstract
Manipulative therapy (MT) is applied to motor organs through a therapist’s hands. Although MT has been utilized in various medical treatments based on its potential role for increasing the blood flow to the local muscle, a quantitative validation of local muscle blood flow in MT remains challenging due to the lack of appropriate bedside evaluation techniques. Therefore, we investigated changes in the local blood flow to the muscle undergoing MT by employing diffuse correlation spectroscopy, a portable and emerging optical measurement technology that non-invasively measures blood flow in deep tissues. This study investigated the changes in blood flow, heart rate, blood pressure, and autonomic nervous activity in the trapezius muscle through MT application in 30 volunteers without neck and shoulder injury. Five minutes of MT significantly increased the median local blood flow relative to that of the pre-MT period (p < 0.05). The post-MT local blood flow increase was significantly higher in the MT condition than in the control condition, where participants remained still without receiving MT for the same time (p < 0.05). However, MT did not affect the heart rate, blood pressure, or cardiac autonomic nervous activity. The post-MT increase in muscle blood flow was significantly higher in the participants with muscle stiffness in the neck and shoulder regions than in those without (p < 0.05). These results suggest that MT could increase the local blood flow to the target skeletal muscle, with minimal effects on systemic circulatory function.
Collapse
Affiliation(s)
- Yasuhiro Matsuda
- Electrical Engineering Program, Graduate School of Science and Technology, Meiji University, Kawasaki, Japan
- Faculty of Medical Science, Nippon Sport Science University, Yokohama, Japan
| | - Mikie Nakabayashi
- Electrical Engineering Program, Graduate School of Science and Technology, Meiji University, Kawasaki, Japan
- Japan Society for the Promotion of Science (JSPS), Tokyo, Japan
| | - Tatsuya Suzuki
- Electrical Engineering Program, Graduate School of Science and Technology, Meiji University, Kawasaki, Japan
| | - Sinan Zhang
- Electrical Engineering Program, Graduate School of Science and Technology, Meiji University, Kawasaki, Japan
- Department of Electronics and Bioinformatics, School of Science and Technology, Meiji University, Kawasaki, Japan
| | - Masashi Ichinose
- Human Integrative Physiology Laboratory, School of Business Administration, Meiji University, Tokyo, Japan
| | - Yumie Ono
- Department of Electronics and Bioinformatics, School of Science and Technology, Meiji University, Kawasaki, Japan
- *Correspondence: Yumie Ono,
| |
Collapse
|
17
|
Cebula A, Cebula M, Kopyta I. Muscle Ultrasonographic Elastography in Children: Review of the Current Knowledge and Application. CHILDREN 2021; 8:children8111042. [PMID: 34828755 PMCID: PMC8623756 DOI: 10.3390/children8111042] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 11/06/2021] [Accepted: 11/10/2021] [Indexed: 02/07/2023]
Abstract
Ultrasonographic elastography is a relatively new imaging modality for the qualitative and quantitative assessments of tissue elasticity. While it has steadily gained use in adult clinical practice, including for liver diseases, breast cancer, thyroid pathologies, and muscle and tendon diseases, data on its paediatric application is still limited. Moreover, diagnosis of muscular diseases in children remains challenging. The gold standard methods, namely biopsy, electroneurography, and electromyography, are often limited owing to their invasive characteristics, possible contraindications, complications, and need for good cooperation, that is, a patient’s ability to perform certain tasks during the examination while withstanding discomfort, which is a significant problem especially in younger or uncooperative children. Genetic testing, which has broad diagnostic possibilities, often entails a high cost, which limits its application. Thus, a non-invasive, objective, repeatable, and accessible tool is needed to aid in both the diagnosis and monitoring of muscle pathologies. We believe that elastography may prove to be such a method. The aim of this review was to present the current knowledge on the use of muscle elastography in the paediatric population and information on the limitations of elastography in relation to examination protocols and factors for consideration in everyday practice and future studies.
Collapse
Affiliation(s)
- Agnieszka Cebula
- Department of Paediatric Neurology, Faculty of Medical Sciences in Katowice, Medical University of Silesia in Katowice, Medykow Str 16, 40-752 Katowice, Poland;
- Correspondence: ; Fax: +48-322071546
| | - Maciej Cebula
- Department of Radiodiagnostics, Invasive Radiology and Nuclear Medicine, Department of Radiology and Nuclear Medicine, Faculty of Medicine in Katowice, Medical University of Silesia in Katowice, Medykow Str 14, 40-752 Katowice, Poland;
| | - Ilona Kopyta
- Department of Paediatric Neurology, Faculty of Medical Sciences in Katowice, Medical University of Silesia in Katowice, Medykow Str 16, 40-752 Katowice, Poland;
| |
Collapse
|
18
|
Miller T, Ying MTC, Chung RCK, Pang MYC. Convergent Validity and Test-Retest Reliability of Multimodal Ultrasonography and Related Clinical Measures in People With Chronic Stroke. Arch Phys Med Rehabil 2021; 103:459-472.e4. [PMID: 34695388 DOI: 10.1016/j.apmr.2021.09.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Revised: 09/18/2021] [Accepted: 09/22/2021] [Indexed: 12/13/2022]
Abstract
OBJECTIVE To assess the test-retest reliability of diagnostic ultrasonography measurements of the bilateral biceps brachii (BB), brachial artery, medial gastrocnemius (MG), and popliteal artery in survivors of stroke and their convergent validity with related clinical comparators. DESIGN Cross-sectional study. SETTING All procedures were conducted in a university laboratory. PARTICIPANTS Sixty-five community dwelling adults (N=65; 26 women, 39 men) with an average age of 60.9±7.7 years and stroke duration of 5.7±3.9 years participated in this study. INTERVENTIONS Not applicable. MAIN OUTCOME MEASURES Measures of muscle structure (ie, thickness, cross-sectional area, fascicle length, pennation angle), stiffness, and intramuscular blood perfusion were conducted using B-mode, elastography and color flow Doppler ultrasonography modes, respectively. Convergent validity was assessed by examining correlations between ultrasonography measures and assessments of related constructs (ie, dynamic stiffness, isometric peak torque, spasticity, and systemic vascular function using myotonometry, dynamometry, the Composite Spasticity Scale, and the Ankle-Brachial Index, respectively). A 2-way random-effects intraclass correlation coefficient (ICC) model (ICC2,3) was used to determine agreement between intersession measures among a smaller cohort of participants with stroke (n=20). RESULTS ICC estimates ranged from moderate to excellent for muscle stiffness (paretic: ICC=0.74-0.89; nonparetic: ICC=0.66-0.88), structure (paretic: ICC=0.87-0.99; nonparetic: ICC=0.81-0.98), and blood perfusion measures (paretic: ICC=0.74-0.84; nonparetic: ICC=0.73-0.88). Weak to moderate associations were found between myotonometry and elastography measures of the bilateral BB (r=0.29-0.52, P≤.05) and MG muscles (r=0.31-0.69, P≤.05). The correlations between elastography measures and spasticity scores for the paretic upper (r=0.35-0.63, P≤.05) and lower limbs (r=0.25-0.37, P≤.05) were also weak to moderate. CONCLUSIONS Elastography demonstrated mostly weak to moderate correlation with measures of stiffness using myotonometry as well as scores of paretic upper and lower limb spasticity. The results also indicate acceptable intersession reliability for muscle and vascular measures using several ultrasonography modalities among individuals with chronic stroke.
Collapse
Affiliation(s)
- Tiev Miller
- Department of Rehabilitation Sciences, Hong Kong Polytechnic University, Hung Hom
| | - Michael T C Ying
- Department of Health Technology and Informatics, Hong Kong Polytechnic University, Hung Hom, Hong Kong SAR
| | - Raymond C K Chung
- Department of Rehabilitation Sciences, Hong Kong Polytechnic University, Hung Hom
| | - Marco Y C Pang
- Department of Rehabilitation Sciences, Hong Kong Polytechnic University, Hung Hom.
| |
Collapse
|
19
|
Mazzo MR, Weinman LE, Giustino V, Mclagan B, Maldonado J, Enoka RM. Changes in neural drive to calf muscles during steady submaximal contractions after repeated static stretches. J Physiol 2021; 599:4321-4336. [PMID: 34292610 DOI: 10.1113/jp281875] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Accepted: 07/19/2021] [Indexed: 01/27/2023] Open
Abstract
KEY POINTS Repeated static-stretching interventions consistently increase the range of motion about a joint and decrease total joint stiffness, but findings on the changes in muscle and connective-tissue properties are mixed. The influence of these stretch-induced changes on muscle function at submaximal forces is unknown. To address this gap in knowledge, the changes in neural drive to the plantar flexor muscles after a static-stretch intervention were estimated. Neural drive to the plantar flexor muscles during a low-force contraction increased after repeated static stretches. These findings suggest that adjustments in motor unit activity are necessary at low forces to accommodate reductions in the force-generating and transmission capabilities of the muscle-tendon unit after repeated static stretches of the calf muscles. ABSTRACT Static stretching decreases stiffness about a joint, but its influence on muscle-tendon unit function and muscle activation is unclear. We investigated the influence of three static stretches on changes in neural drive to the plantar flexor muscles, both after a stretch intervention and after a set of maximal voluntary contractions (MVCs). Estimates of neural drive were obtained during submaximal isometric contractions by decomposing high-density electromyographic signals into the activity of individual motor units from medial gastrocnemius, lateral gastrocnemius and soleus. Motor units were matched across contractions and an estimate of neural drive to the plantar flexors was calculated by normalizing the cumulative spike train to the number of active motor units (normalized neural drive). Mean discharge rate increased after the stretch intervention during the 10% MVC task for all recorded motor units and those matched across conditions (all, P = 0.0046; matched only, P = 0.002), recruitment threshold decreased for motor units matched across contractions (P = 0.022), and discharge rate at recruitment was elevated (P = 0.004). Similarly, the estimate of normalized neural drive was significantly greater after the stretch intervention at 10% MVC torque (P = 0.029), but not at 35% MVC torque. The adjustments in motor unit activity required to complete the 10% MVC task after stretch may have been partially attenuated by a set of plantar flexor MVCs. The increase in neural drive required to produce low plantar-flexion torques after repeated static stretches of the calf muscles suggests stretch-induced changes in muscle and connective tissue properties.
Collapse
Affiliation(s)
- Melissa R Mazzo
- Department of Integrative Physiology, University of Colorado, Boulder, CO, USA
| | - Logan E Weinman
- Department of Integrative Physiology, University of Colorado, Boulder, CO, USA
| | - Valerio Giustino
- Sport and Exercise Sciences Research Unit, Department of Psychology, Educational Science and Human Movement, University of Palermo, Palermo, Italy
| | - Bailey Mclagan
- Department of Integrative Physiology, University of Colorado, Boulder, CO, USA
| | - John Maldonado
- Department of Integrative Physiology, University of Colorado, Boulder, CO, USA
| | - Roger M Enoka
- Department of Integrative Physiology, University of Colorado, Boulder, CO, USA
| |
Collapse
|
20
|
Takeuchi K, Sato S, Kiyono R, Yahata K, Murakami Y, Sanuki F, Yoshida R, Nakamura M. High-Intensity Static Stretching in Quadriceps Is Affected More by Its Intensity Than Its Duration. Front Physiol 2021; 12:709655. [PMID: 34290625 PMCID: PMC8287525 DOI: 10.3389/fphys.2021.709655] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Accepted: 06/14/2021] [Indexed: 11/13/2022] Open
Abstract
A previous study reported that 3-min of high-intensity static stretching at an intensity of 120% of range of motion (ROM) did not change the muscle stiffness of the rectus femoris, because of the overly high stress of the stretching. The purpose of this study was to examine the effects of high-intensity static stretching of a shorter duration or lower intensity on the flexibility of the rectus femoris than that of the previous study. Two experiments were conducted (Experiment 1 and 2). In Experiment 1, eleven healthy men underwent static stretching at the intensity of 120% of ROM for two different durations (1 and 3 min). In Experiment 2, fifteen healthy men underwent 3-min of static stretching at the intensity of 110% of ROM. The shear elastic modulus of the quadriceps were measured. In Experiment 1, ROM increased in both interventions (p < 0.01), but the shear elastic modulus of the rectus femoris was not changed. In Experiment 2, ROM significantly increased (p < 0.01), and the shear elastic modulus of the rectus femoris significantly decreased (p < 0.05). It was suggested that the stretching intensity (110%) is more important than stretching duration to decrease the muscle stiffness of the rectus femoris.
Collapse
Affiliation(s)
- Kosuke Takeuchi
- Department of Physical Therapy, Graduate School of Medicine, Kobe University, Kobe, Japan
| | - Shigeru Sato
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan
| | - Ryosuke Kiyono
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan
| | - Kaoru Yahata
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan
| | - Yuta Murakami
- Department of Physical Therapy, Niigata University of Health and Welfare, Niigata, Japan
| | - Futaba Sanuki
- Department of Physical Therapy, Niigata University of Health and Welfare, Niigata, Japan
| | - Riku Yoshida
- Department of Physical Therapy, Niigata University of Health and Welfare, Niigata, Japan
| | - Masatoshi Nakamura
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan.,Department of Physical Therapy, Niigata University of Health and Welfare, Niigata, Japan
| |
Collapse
|
21
|
Lee Y, Kim M, Lee H. The Measurement of Stiffness for Major Muscles with Shear Wave Elastography and Myoton: A Quantitative Analysis Study. Diagnostics (Basel) 2021; 11:diagnostics11030524. [PMID: 33804273 PMCID: PMC7999852 DOI: 10.3390/diagnostics11030524] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 03/09/2021] [Accepted: 03/10/2021] [Indexed: 12/20/2022] Open
Abstract
The present study was performed to assess the relationship between hand-held myotonometer MyotonPRO and shear wave elastography (SWE) measurements of lower limb muscle stiffness during resting and active voluntary contraction. Forty healthy young adults, (20 males and 20 females) participated in the study. The stiffness of each subject’s rectus femoris (RF), biceps femoris (BF), tibialis anterior (TA), and medial gastrocnemius (MG) was measured repeatedly by MyotonPRO and SWE. Moderate to strong correlations between the two methods’ measurements were found for both resting and active voluntary contraction. (r = 0.416–0.669, p < 0.05; r = 0.398–0.594, p < 0.05, respectively). Muscle stiffness at rest was significantly lower compared contraction in all four muscles measured by both methods (p < 0.05). Intra-rater reliabilities were generally lower when measurements were taken during contraction. Additionally, when compared by gender, muscle stiffness measured by MyotonPRO was significantly higher at rest in men compared to women, except for the TA. However, a significant difference was found in TA muscle stiffness by gender when measured with SWE. When muscles were contracted, all muscles showed significantly higher stiffness in men compared to women. There were moderate to good correlations in muscle stiffness between measurements of SWE and MyotonPRO at rest and during active voluntary contraction. Additionally, both instruments showed good intra-rater reliability.
Collapse
Affiliation(s)
- Youngjin Lee
- Department of Radiology Science, Gachon University, Incheon 21936, Korea; (Y.L.); (M.K.)
| | - Minkyoung Kim
- Department of Radiology Science, Gachon University, Incheon 21936, Korea; (Y.L.); (M.K.)
- Department of Radiology, Kwanghye Hospital, Seoul 06174, Korea
| | - Haneul Lee
- Department of Physical Therapy, Gachon University, Incheon 21936, Korea
- Correspondence:
| |
Collapse
|
22
|
Asayama A, Tateuchi H, Ota M, Motomura Y, Yanase K, Komamura T, Ichihashi N. Differences in shear elastic modulus of the latissimus dorsi muscle during stretching among varied trunk positions. J Biomech 2021; 118:110324. [PMID: 33618168 DOI: 10.1016/j.jbiomech.2021.110324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 11/25/2020] [Accepted: 01/31/2021] [Indexed: 11/29/2022]
Abstract
The latissimus dorsi (LD) can be divided into the upper, middle, and lower parts, but the effective stretching positions for each part are unknown. In this study, we aimed to investigate effective trunk positions for stretching of the LD. A total of 14 healthy males participated in this study. The following seven trunk positions were chosen as the LD stretching positions; upright of the trunk (Baseline), flexion of the trunk (Flex), contralateral bending of the trunk (LB), contralateral rotation of the trunk (Rot), flexion and contralateral bending of the trunk (Flex + LB), flexion and contralateral rotation of the trunk (Flex + Rot), and contralateral bending and contralateral rotation of the trunk (LB + Rot). Maximal elevation of the upper limb was passively added to all positions. The shear elastic modulus, used as the index of muscle elongation, was measured at the four parts (upper, middle, lower, distal parts) of the LD. The shear elastic moduli showed obviously high values in Rot and LB + Rot at the upper, middle, and distal parts, and also in LB, Rot, and LB + Rot at the lower part. These findings suggest that contralateral trunk rotation, or a combination of contralateral trunk bending and rotation are effective trunk positions for stretching all parts of the LD. Contralateral trunk bending was also effective for stretching the lower part of the LD.
Collapse
Affiliation(s)
- Akihiro Asayama
- Human Health Sciences, Graduate School of Medicine, Kyoto University, Japan.
| | - Hiroshige Tateuchi
- Human Health Sciences, Graduate School of Medicine, Kyoto University, Japan
| | - Megumi Ota
- Human Health Sciences, Graduate School of Medicine, Kyoto University, Japan
| | - Yoshiki Motomura
- Human Health Sciences, Graduate School of Medicine, Kyoto University, Japan
| | - Ko Yanase
- Human Health Sciences, Graduate School of Medicine, Kyoto University, Japan
| | | | - Noriaki Ichihashi
- Human Health Sciences, Graduate School of Medicine, Kyoto University, Japan
| |
Collapse
|
23
|
Nakamura M, Sato S, Murakami Y, Kiyono R, Yahata K, Sanuki F, Yoshida R, Fukaya T, Takeuchi K. The Comparison of Different Stretching Intensities on the Range of Motion and Muscle Stiffness of the Quadriceps Muscles. Front Physiol 2021; 11:628870. [PMID: 33519530 PMCID: PMC7838703 DOI: 10.3389/fphys.2020.628870] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 12/09/2020] [Indexed: 12/23/2022] Open
Abstract
Muscle strain is one of the most frequent sports injuries, having the rectus femoris (RF) muscle as the reported preferred site of quadriceps muscle strain. The decrease muscle stiffness could be an effective RF muscle strain prevention. In recent studies, a high-intensity static stretching intervention decreased passive stiffness, though no study has investigated on the effect of the different static stretching intervention intensities on quadriceps muscle stiffness. The purpose of this study was to investigate the three different quadriceps muscle stiffness intensities (120 vs. 100 vs. 80%). Eighteen healthy, sedentary male volunteers participated in the study and randomly performed three intensities. The static stretching intervention was performed in knee flexion with 30° hip extension. Three 60-second stretching intervention with a 30-second interval were performed at each stretching intensity. We measured knee flexion range of motion and shear elastic modulus of the RF muscle used by ultrasonic shear-wave elastography before and after the static stretching intervention. Our results showed that the knee flexion range of motion was increased after 100% (p < 0.01) and 120% intensities (p < 0.01) static stretching intervention, not in 80% intensity (p = 0.853). In addition, our results showed that the shear elastic modulus of the RF muscle was decreased only after 100% intensity static stretching intervention (p < 0.01), not after 80% (p = 0.365), and 120% intensities (p = 0.743). To prevent the quadriceps muscle strain, especially the RF muscle, 100%, not 120% (high) and 80% (low), intensity stretching could be beneficial in sports setting application.
Collapse
Affiliation(s)
- Masatoshi Nakamura
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan.,Department of Physical Therapy, Niigata University of Health and Welfare, Niigata, Japan
| | - Shigeru Sato
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan
| | - Yuta Murakami
- Department of Physical Therapy, Niigata University of Health and Welfare, Niigata, Japan
| | - Ryosuke Kiyono
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan
| | - Kaoru Yahata
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan
| | - Futaba Sanuki
- Department of Physical Therapy, Niigata University of Health and Welfare, Niigata, Japan
| | - Riku Yoshida
- Department of Physical Therapy, Niigata University of Health and Welfare, Niigata, Japan
| | - Taizan Fukaya
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan.,Department of Rehabilitation, Kyoto Kujo Hospital, Kyoto, Japan
| | - Kosuke Takeuchi
- Department of Physical Therapy, Faculty of Rehabilitation, Kobe International University, Hyogo, Japan
| |
Collapse
|
24
|
Jędrzejewski G, Kasper-Jędrzejewska M, Dolibog P, Szyguła R, Schleip R, Halski T. The Rolf Method of Structural Integration on Fascial Tissue Stiffness, Elasticity, and Superficial Blood Perfusion in Healthy Individuals: The Prospective, Interventional Study. Front Physiol 2020; 11:1062. [PMID: 33041843 PMCID: PMC7522439 DOI: 10.3389/fphys.2020.01062] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Accepted: 07/31/2020] [Indexed: 12/16/2022] Open
Abstract
Introduction: There are multiple theories surrounding the physiological impact of structural integration (SI) with little evidence or research corroborating any of these. The aim of the study was to assess the effectiveness of 10 sessions of SI on fascial tissue (FT) superficial blood perfusion, stiffness, and elasticity in 13 healthy women. Methods: This was a prospective, interventional study. The primary outcome measures were FTs’ superficial blood perfusion, stiffness, and elasticity of bilateral selected FT points on the body. Data were collected before and after 10 sessions of SI intervention. Statistical analysis was performed using the non-parametric Wilcoxon test (intragroup comparison). Results: The superficial blood perfusion increased significantly in the most selected FT points on the body (p < 0.05). SI interventions produced significant decreases in selected points (brachioradialis, biceps brachii, and trapezius; p < 0.05) of FT stiffness and significant increases in elasticity (brachioradialis, biceps brachii, triceps surae, and trapezius; p < 0.05), especially in the FT of the right (dominant) upper limb. Conclusion: A 10-session of SI demonstrated positive effects on increasing superficial blood perfusion contributed to a decrease in FT stiffness and an increase in elasticity properties in the dominant upper limb. Data collection for this study is currently underway, and the trial is registered at ISRCTN.com with the identifier: ISRCTN46707309.
Collapse
Affiliation(s)
| | | | - Paweł Dolibog
- Faculty of Health Sciences, University of Opole, Opole, Poland
| | - Renata Szyguła
- Faculty of Health Sciences, University of Opole, Opole, Poland
| | - Robert Schleip
- Department of Sport and Health Sciences, Technical University Munich, Munich, Germany.,Diploma University of Applied Sciences, Bad Sooden-Allendorf, Germany
| | - Tomasz Halski
- Faculty of Health Sciences, University of Opole, Opole, Poland
| |
Collapse
|
25
|
Hirata K, Yamadera R, Akagi R. Can Static Stretching Reduce Stiffness of the Triceps Surae in Older Men? Med Sci Sports Exerc 2020; 52:673-679. [PMID: 31652247 PMCID: PMC7034366 DOI: 10.1249/mss.0000000000002186] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Purpose The purpose of this study was to investigate reductions of muscle stiffness induced by static stretching in older and younger men. Methods Twenty older (62–83 yr) and 20 younger (21–24 yr) men were recruited. Ankle dorsiflexion static stretching was consisted of 90 s × 5 repetitions. Before and after the stretching, the dorsiflexion range of motion (RoM), passive plantar flexion torque, and shear modulus (an index of stiffness) of the medial (MG) and lateral gastrocnemius and the soleus were measured. Results RoM, passive torque, and shear modulus of the triceps surae measured at the maximal dorsiflexion angle before stretching were significantly lower for the older group than the younger group. This suggests a weak stretching intensity for older compared with younger people. The stretching significantly improved RoM for both groups. For the older group, a significant reduction in passive torque was only observed at a 15° dorsiflexion angle, and the shear modulus was significantly decreased only for the distal region of MG. For the younger group, passive torque was significantly reduced for the entire RoM, and a significant decrease in shear modulus was found for the central and distal regions of MG and lateral gastrocnemius. A significant correlation between the muscle shear modulus measured at the maximal dorsiflexion angle before stretching and a stretching-induced decrease in muscle shear modulus was observed for older and younger participants. This indicates that the higher stretching intensity can reduce more muscle stiffness. Conclusion Static stretching can reduce muscle stiffness regardless of age, although the stretching effect on muscle stiffness was limited for older people. This might be due to a lower stretching intensity for older than younger people.
Collapse
Affiliation(s)
| | - Ryosuke Yamadera
- College of Systems Engineering and Science, Shibaura Institute of Technology, Saitama-shi, Saitama, JAPAN
| | | |
Collapse
|