Karius A, Leifeld LM, Strnad V, Fietkau R, Bert C. First implementation of an innovative infra-red camera system integrated into a mobile CBCT scanner for applicator tracking in brachytherapy-Initial performance characterization. J Appl Clin Med Phys 2024; 25:e14364. [PMID: 38626753 PMCID: PMC11244686 DOI: 10.1002/acm2.14364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 03/24/2024] [Accepted: 03/28/2024] [Indexed: 04/18/2024] Open
Abstract
PURPOSE To enable a real-time applicator guidance for brachytherapy, we used for the first time infra-red tracking cameras (OptiTrack, USA) integrated into a mobile cone-beam computed tomography (CBCT) scanner (medPhoton, Austria). We provide the first description of this prototype and its performance evaluation. METHODS We performed assessments of camera calibration and camera-CBCT registration using a geometric calibration phantom. For this purpose, we first evaluated the effects of intrinsic parameters such as camera temperature or gantry rotations on the tracked marker positions. Afterward, calibrations with various settings (sample number, field of view coverage, calibration directions, calibration distances, and lighting conditions) were performed to identify the requirements for achieving maximum tracking accuracy based on an in-house phantom. The corresponding effects on camera-CBCT registration were determined as well by comparing tracked marker positions to the positions determined via CBCT. Long-term stability was assessed by comparing tracking and a ground-truth on a weekly basis for 6 weeks. RESULTS Robust tracking with positional drifts of 0.02 ± 0.01 mm was feasible using the system after a warm-up period of 90 min. However, gantry rotations affected the tracking and led to inaccuracies of up to 0.70 mm. We identified that 4000 samples and full coverage were required to ensure a robust determination of marker positions and camera-CBCT registration with geometric deviations of 0.18 ± 0.03 mm and 0.42 ± 0.07 mm, respectively. Long-term stability showed deviations of more than two standard deviations from the initial calibration after 3 weeks. CONCLUSION We implemented for the first time a standalone combined camera-CBCT system for tracking in brachytherapy. The system showed high potential for establishing corresponding workflows.
Collapse
Affiliation(s)
- Andre Karius
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
- Comprehensive Cancer Center Erlangen-EMN (CCC ER-EMN), Erlangen, Germany
| | - Lisa Marie Leifeld
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
- Comprehensive Cancer Center Erlangen-EMN (CCC ER-EMN), Erlangen, Germany
| | - Vratislav Strnad
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
- Comprehensive Cancer Center Erlangen-EMN (CCC ER-EMN), Erlangen, Germany
| | - Rainer Fietkau
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
- Comprehensive Cancer Center Erlangen-EMN (CCC ER-EMN), Erlangen, Germany
| | - Christoph Bert
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
- Comprehensive Cancer Center Erlangen-EMN (CCC ER-EMN), Erlangen, Germany
| |
Collapse
|
2
|
Eckroate B, Ayala‐Peacock D, Venkataraman R, Campelo S, Chino J, Stephens SJ, Kim Y, Meltsner S, Raffi J, Craciunescu O. A novel multi-modality imaging phantom for validating interstitial needle guidance for high dose rate gynecological brachytherapy. J Appl Clin Med Phys 2023; 24:e14075. [PMID: 37335537 PMCID: PMC10562025 DOI: 10.1002/acm2.14075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 05/03/2023] [Accepted: 06/02/2023] [Indexed: 06/21/2023] Open
Abstract
PURPOSE To design, manufacture, and validate a female pelvic phantom for multi-modality imaging (CT, MRI, US) to benchmark a commercial needle tracking system with application in HDR gynecological (GYN) interstitial procedures. MATERIALS AND METHODS A GYN needle-tracking phantom was designed using CAD software to model an average uterus from a previous patient study, a vaginal canal from speculum dimensions, and a rectum to accommodate a transrectal ultrasound (TRUS) probe. A target volume (CTVHR ) was designed as an extension from the cervix-uterus complex. Negative space molds were created from modeled anatomy and 3D printed. Silicone was used to cast the anatomy molds. A 3D printed box was constructed to house the manufactured anatomy for structural integrity and to accommodate the insertion of a speculum, tandem, needles, and TRUS probe. The phantom was CT-imaged to identify potential imperfections that might impact US visualization. Free-hand TRUS was used to guide interstitial needles into the phantom. The commercial tracking system was used to generate a 3D US volume. After insertion, the phantom was imaged with CT and MR and the uterus and CTVHR dimensions were verified against the CAD model. RESULTS/CONCLUSIONS The manufactured phantom allows for accurate visualization with multiple imaging modalities and is conducive to applicator and needle insertion. The phantom dimensions from the CAD model were verified with those from each imaging modality. The phantom is low cost and can be reproducibly manufactured with the 3D printing and molding processes. Our initial experiments demonstrate the ability to integrate the phantom with a commercial tracking system for future needle tracking validation studies.
Collapse
Affiliation(s)
- Brett Eckroate
- Department of Radiation OncologyRutgers UniversityNew BrunswickNew JerseyUSA
| | - Diandra Ayala‐Peacock
- Department of Radiation OncologyDuke University Medical CenterDurhamNorth CarolinaUSA
| | | | - Sabrina Campelo
- Virginia Tech‐Wake Forest School of Biomedical Engineering and SciencesBlacksburgVirginiaUSA
| | - Junzo Chino
- Department of Radiation OncologyDuke University Medical CenterDurhamNorth CarolinaUSA
| | - Sarah Jo Stephens
- Department of Radiation OncologyDuke University Medical CenterDurhamNorth CarolinaUSA
| | - Yongbok Kim
- Department of Radiation OncologyDuke University Medical CenterDurhamNorth CarolinaUSA
| | - Sheridan Meltsner
- Department of Radiation OncologyDuke University Medical CenterDurhamNorth CarolinaUSA
| | - Julie Raffi
- Department of Radiation OncologyDuke University Medical CenterDurhamNorth CarolinaUSA
| | - Oana Craciunescu
- Department of Radiation OncologyDuke University Medical CenterDurhamNorth CarolinaUSA
| |
Collapse
|
3
|
3D-printed template and optical needle navigation in CT-guided iodine-125 permanent seed implantation. J Contemp Brachytherapy 2021; 13:410-418. [PMID: 34484355 PMCID: PMC8407253 DOI: 10.5114/jcb.2021.108595] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Accepted: 06/15/2021] [Indexed: 11/17/2022] Open
Abstract
Purpose To preliminarily verify the accuracy of navigation-assisted seed implantation by comparing pre-operative and actual differences in puncture characteristics and dosimetry in computed tomography (CT)-guided, navigation-assisted radioactive iodine-125 seed implantation, using 3D-printed templates for malignant tumors’ treatment. Material and methods A total of 27 tumor patients, who were treated with seed implantation under combination guidance in our hospital between December 2019 and December 2020 were enrolled in this study. Navigation needles (n = 1-3) were placed in each patient to obtain pre-operative and intra-operative puncture information, such as angle, depth, insertion point, and tip position. Moreover, dosimetry parameters in pre-operative and post-operative plans, including D90, V100, V150, V200, minimum peripheral dose (MPD), conformal index, external index, and homogeneity index of target area were investigated. Results Mean errors of the angle, depth, insertion point, and tip position were 0.5 ±0.5°, 4.0 ±2.0 mm, 1.7 ±1 mm, and 3.1 ±1.8 mm, respectively. There were no significant differences between intra-operative and pre-operative angles (p = 0.271), but there was a significant difference in the depth (p = 0.002). Errors of the angle, depth, and insertion point were larger for the pelvic/retroperitoneal area than for the head and neck/chest wall (p < 0.05). With the exception of MPD, there was no significant difference in dosimetry indices between post-operative and preoperative plans (p > 0.05). Conclusions Seed implantation under combination guidance showed good accuracy, and the actual intra-operative puncture information and post-operative doses were in agreement with those in the pre-operative plan, thereby demonstrating promising prospects for further development.
Collapse
|
4
|
Wilby S, Palmer A, Polak W, Bucchi A. A review of brachytherapy physical phantoms developed over the last 20 years: clinical purpose and future requirements. J Contemp Brachytherapy 2021; 13:101-115. [PMID: 34025743 PMCID: PMC8117707 DOI: 10.5114/jcb.2021.103593] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Accepted: 11/13/2020] [Indexed: 12/04/2022] Open
Abstract
Within the brachytherapy community, many phantoms are constructed in-house, and less commercial development is observed as compared to the field of external beam. Computational or virtual phantom design has seen considerable growth; however, physical phantoms are beneficial for brachytherapy, in which quality is dependent on physical processes, such as accuracy of source placement. Focusing on the design of physical phantoms, this review paper presents a summary of brachytherapy specific phantoms in published journal articles over the last twenty years (January 1, 2000 - December 31, 2019). The papers were analyzed and tabulated by their primary clinical purpose, which was deduced from their associated publications. A substantial body of work has been published on phantom designs from the brachytherapy community, but a standardized method of reporting technical aspects of the phantoms is lacking. In-house phantom development demonstrates an increasing interest in magnetic resonance (MR) tissue mimicking materials, which is not yet reflected in commercial phantoms available for brachytherapy. The evaluation of phantom design provides insight into the way, in which brachytherapy practice has changed over time, and demonstrates the customised and broad nature of treatments offered.
Collapse
Affiliation(s)
- Sarah Wilby
- Department of Radiotherapy Physics, Clinical Hematology, and Oncology Centre, Portsmouth Hospitals NHS Trust, Cosham, Portsmouth, United Kingdom
- Department of Mechanical Engineering, Faculty of Technology University of Portsmouth, Portsmouth, United Kingdom
| | - Antony Palmer
- Department of Radiotherapy Physics, Clinical Hematology, and Oncology Centre, Portsmouth Hospitals NHS Trust, Cosham, Portsmouth, United Kingdom
- Department of Mechanical Engineering, Faculty of Technology University of Portsmouth, Portsmouth, United Kingdom
| | - Wojciech Polak
- Department of Radiotherapy Physics, Clinical Hematology, and Oncology Centre, Portsmouth Hospitals NHS Trust, Cosham, Portsmouth, United Kingdom
- Department of Mechanical Engineering, Faculty of Technology University of Portsmouth, Portsmouth, United Kingdom
| | - Andrea Bucchi
- Department of Mechanical Engineering, Faculty of Technology University of Portsmouth, Portsmouth, United Kingdom
| |
Collapse
|
5
|
Rodgers JR, Bax J, Surry K, Velker V, Leung E, D'Souza D, Fenster A. Intraoperative 360-deg three-dimensional transvaginal ultrasound during needle insertions for high-dose-rate transperineal interstitial gynecologic brachytherapy of vaginal tumors. J Med Imaging (Bellingham) 2019; 6:025001. [PMID: 30989088 DOI: 10.1117/1.jmi.6.2.025001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Accepted: 03/13/2019] [Indexed: 11/14/2022] Open
Abstract
Brachytherapy, a type of radiotherapy, may be used to place radioactive sources into or in close proximity to tumors, providing a method for conformally escalating dose in the tumor and the local area surrounding the malignancy. High-dose-rate interstitial brachytherapy of vaginal tumors requires precise placement of multiple needles through holes in a plastic perineal template to deliver treatment while optimizing dose and avoiding overexposure of nearby organs at risk (OARs). Despite the importance of needle placement, image guidance for adaptive, intraoperative needle visualization, allowing misdirected needles to be identified and corrected during insertion, is not standard practice. We have developed a 360-deg three-dimensional (3-D) transvaginal ultrasound (TVUS) system using a conventional probe with a template-compatible custom sonolucent vaginal cylinder and propose its use for intraoperative needle guidance during interstitial gynecologic brachytherapy. We describe the 3-D TVUS mechanism and geometric validation, present mock phantom procedure results, and report on needle localization accuracy in patients. For the six patients imaged, landmark anatomical features and all needles were clearly visible. The implementation of 360-deg 3-D TVUS through a sonolucent vaginal cylinder provides a technique for visualizing needles and OARs intraoperatively during interstitial gynecologic brachytherapy, enabling implants to be assessed and providing the potential for image guidance.
Collapse
Affiliation(s)
- Jessica Robin Rodgers
- University of Western Ontario, School of Biomedical Engineering, London, Ontario, Canada.,University of Western Ontario, Robarts Research Institute, London, Ontario, Canada
| | - Jeffrey Bax
- University of Western Ontario, Robarts Research Institute, London, Ontario, Canada
| | - Kathleen Surry
- London Health Sciences Centre, Department of Medical Physics, London Regional Cancer Program, London, Ontario, Canada
| | - Vikram Velker
- London Health Sciences Centre, Department of Radiation Oncology, London Regional Cancer Program, London, Ontario, Canada
| | - Eric Leung
- Sunnybrook Health Sciences Centre, Department of Radiation Oncology, Odette Cancer Centre, Toronto, Ontario, Canada
| | - David D'Souza
- London Health Sciences Centre, Department of Radiation Oncology, London Regional Cancer Program, London, Ontario, Canada
| | - Aaron Fenster
- University of Western Ontario, School of Biomedical Engineering, London, Ontario, Canada.,University of Western Ontario, Robarts Research Institute, London, Ontario, Canada
| |
Collapse
|
6
|
Lugez E, Sadjadi H, Joshi CP, Hashtrudi-Zaad K, Akl SG, Fichtinger G. Field distortion compensation for electromagnetic tracking of ultrasound probes with application in high-dose-rate prostate brachytherapy. Biomed Phys Eng Express 2019. [DOI: 10.1088/2057-1976/ab12b6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
7
|
Richart J, Carmona-Meseguer V, García-Martínez T, Herreros A, Otal A, Pellejero S, Tornero-López A, Pérez-Calatayud J. Review of strategies for MRI based reconstruction of endocavitary and interstitial applicators in brachytherapy of cervical cancer. Rep Pract Oncol Radiother 2018; 23:547-561. [PMID: 30534019 PMCID: PMC6277512 DOI: 10.1016/j.rpor.2018.06.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Revised: 04/04/2018] [Accepted: 06/23/2018] [Indexed: 12/14/2022] Open
Abstract
Brachytherapy plays an essential role in the curative intent management of locally advanced cervical cancer. The introduction of the magnetic resonance (MR) as a preferred image modality and the development of new type of applicators with interstitial components have further improved its benefits. The aim of this work is to review the current status of one important aspect in the cervix cancer brachytherapy procedure, namely catheter reconstruction. MR compatible intracavitary and interstitial applicators are described. Considerations about the use of MR imaging (MRI) regarding appropriate strategies for applicator reconstruction, technical requirements, MR sequences, patient preparation and applicator commissioning are included. It is recommendable to perform the reconstruction process in the same image study employed by the physician for contouring, that is, T2 weighted (T2W) sequences. Nevertheless, a clear identification of the source path inside the catheters and the applicators is a challenge when using exclusively T2W sequences. For the intracavitary component of the implant, sometimes the catheters may be filled with some substance that produces a high intensity signal on MRI. However, this strategy is not feasible for plastic tubes or titanium needles, which, moreover, induce magnetic susceptibility artifacts. In these situations, the use of applicator libraries available in the treatment planning system (TPS) is useful, since they not only include accurate geometrical models of the intracavitary applicators, but also recent developments have made possible the implementation of the interstitial component. Another strategy to improve the reconstruction process is based on the incorporation of MR markers, such as small pellets, to be used as anchor points. Many institutions employ computed tomography (CT) as a supporting image modality. The registration of CT and MR image sets should be carefully performed, and its uncertainty previously assessed. Besides, an important research work is being carried out regarding the use of ultrasound and electromagnetic tracking technologies.
Collapse
Affiliation(s)
- José Richart
- Hospital Clínica Benidorm, Medical Physics Department, Alicante, Spain
| | - Vicente Carmona-Meseguer
- Hospital La Fe-IRIMED, Department of Radiation Oncology, Medical Physics Section, Valencia, Spain
| | | | - Antonio Herreros
- Hospital Clínic, Department of Radiation Oncology, Medical Physics Section, Barcelona, Spain
| | - Antonio Otal
- Hospital Arnau de Vilanova, Medical Physics Department, Lleida, Spain
| | - Santiago Pellejero
- Complejo Hospitalario de Navarra, Medical Physics Department, Pamplona, Spain
| | - Ana Tornero-López
- Hospital Dr. Negrín, Medical Physics Department, Las Palmas de Gran Canaria, Spain
| | - José Pérez-Calatayud
- Hospital La Fe-IRIMED, Department of Radiation Oncology, Medical Physics Section, Valencia, Spain
| |
Collapse
|
8
|
Lugez E, Sadjadi H, Joshi CP, Akl SG, Fichtinger G. Improved electromagnetic tracking for catheter path reconstruction with application in high-dose-rate brachytherapy. Int J Comput Assist Radiol Surg 2017; 12:681-689. [PMID: 28215003 DOI: 10.1007/s11548-017-1534-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2016] [Accepted: 02/01/2017] [Indexed: 10/20/2022]
Abstract
PURPOSE Electromagnetic (EM) catheter tracking has recently been introduced in order to enable prompt and uncomplicated reconstruction of catheter paths in various clinical interventions. However, EM tracking is prone to measurement errors which can compromise the outcome of the procedure. Minimizing catheter tracking errors is therefore paramount to improve the path reconstruction accuracy. METHODS An extended Kalman filter (EKF) was employed to combine the nonlinear kinematic model of an EM sensor inside the catheter, with both its position and orientation measurements. The formulation of the kinematic model was based on the nonholonomic motion constraints of the EM sensor inside the catheter. Experimental verification was carried out in a clinical HDR suite. Ten catheters were inserted with mean curvatures varying from 0 to [Formula: see text] in a phantom. A miniaturized Ascension (Burlington, Vermont, USA) trakSTAR EM sensor (model 55) was threaded within each catheter at various speeds ranging from 7.4 to [Formula: see text]. The nonholonomic EKF was applied on the tracking data in order to statistically improve the EM tracking accuracy. A sample reconstruction error was defined at each point as the Euclidean distance between the estimated EM measurement and its corresponding ground truth. A path reconstruction accuracy was defined as the root mean square of the sample reconstruction errors, while the path reconstruction precision was defined as the standard deviation of these sample reconstruction errors. The impacts of sensor velocity and path curvature on the nonholonomic EKF method were determined. Finally, the nonholonomic EKF catheter path reconstructions were compared with the reconstructions provided by the manufacturer's filters under default settings, namely the AC wide notch and the DC adaptive filter. RESULTS With a path reconstruction accuracy of 1.9 mm, the nonholonomic EKF surpassed the performance of the manufacturer's filters (2.4 mm) by 21% and the raw EM measurements (3.5 mm) by 46%. Similarly, with a path reconstruction precision of 0.8 mm, the nonholonomic EKF surpassed the performance of the manufacturer's filters (1.0 mm) by 20% and the raw EM measurements (1.7 mm) by 53%. Path reconstruction accuracies did not follow an apparent trend when varying the path curvature and sensor velocity; instead, reconstruction accuracies were predominantly impacted by the position of the EM field transmitter ([Formula: see text]). CONCLUSION The advanced nonholonomic EKF is effective in reducing EM measurement errors when reconstructing catheter paths, is robust to path curvature and sensor speed, and runs in real time. Our approach is promising for a plurality of clinical procedures requiring catheter reconstructions, such as cardiovascular interventions, pulmonary applications (Bender et al. in medical image computing and computer-assisted intervention-MICCAI 99. Springer, Berlin, pp 981-989, 1999), and brachytherapy.
Collapse
Affiliation(s)
- Elodie Lugez
- Laboratory for Percutaneous Surgery, School of Computing, Queen's University, Kingston, Canada.
| | - Hossein Sadjadi
- Laboratory for Percutaneous Surgery, School of Computing, Queen's University, Kingston, Canada
| | - Chandra P Joshi
- Cancer Centre of Southeastern Ontario, Kingston General Hospital, Kingston, Canada
| | - Selim G Akl
- School of Computing, Queen's University, Kingston, Canada
| | - Gabor Fichtinger
- Laboratory for Percutaneous Surgery, School of Computing, Queen's University, Kingston, Canada
| |
Collapse
|
9
|
Electromagnetic tracking for treatment verification in interstitial brachytherapy. J Contemp Brachytherapy 2016; 8:448-453. [PMID: 27895688 PMCID: PMC5116452 DOI: 10.5114/jcb.2016.63356] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2016] [Accepted: 10/04/2016] [Indexed: 11/29/2022] Open
Abstract
Electromagnetic tracking (EMT) is used in several medical fields to determine the position and orientation of dedicated sensors, e.g., attached to surgical tools. Recently, EMT has been introduced to brachytherapy for implant reconstruction and error detection. The manuscript briefly summarizes the main issues of EMT and error detection in brachytherapy. The potential and complementarity of EMT as treatment verification technology will be discussed in relation to in vivo dosimetry and imaging.