1
|
Sheth N, Vagdargi P, Sisniega A, Uneri A, Osgood G, Siewerdsen JH. Preclinical evaluation of a prototype freehand drill video guidance system for orthopedic surgery. J Med Imaging (Bellingham) 2022; 9:045004. [PMID: 36046335 PMCID: PMC9411797 DOI: 10.1117/1.jmi.9.4.045004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Accepted: 08/09/2022] [Indexed: 08/28/2023] Open
Abstract
Purpose: Internal fixation of pelvic fractures is a challenging task requiring the placement of instrumentation within complex three-dimensional bone corridors, typically guided by fluoroscopy. We report a system for two- and three-dimensional guidance using a drill-mounted video camera and fiducial markers with evaluation in first preclinical studies. Approach: The system uses a camera affixed to a surgical drill and multimodality (optical and radio-opaque) markers for real-time trajectory visualization in fluoroscopy and/or CT. Improvements to a previously reported prototype include hardware components (mount, camera, and fiducials) and software (including a system for detecting marker perturbation) to address practical requirements necessary for translation to clinical studies. Phantom and cadaver experiments were performed to quantify the accuracy of video-fluoroscopy and video-CT registration, the ability to detect marker perturbation, and the conformance in placing guidewires along realistic pelvic trajectories. The performance was evaluated in terms of geometric accuracy and conformance within bone corridors. Results: The studies demonstrated successful guidewire delivery in a cadaver, with a median entry point error of 1.00 mm (1.56 mm IQR) and median angular error of 1.94 deg (1.23 deg IQR). Such accuracy was sufficient to guide K-wire placement through five of the six trajectories investigated with a strong level of conformance within bone corridors. The sixth case demonstrated a cortical breach due to extrema in the registration error. The system was able to detect marker perturbations and alert the user to potential registration issues. Feasible workflows were identified for orthopedic-trauma scenarios involving emergent cases (with no preoperative imaging) or cases with preoperative CT. Conclusions: A prototype system for guidewire placement was developed providing guidance that is potentially compatible with orthopedic-trauma workflow. First preclinical (cadaver) studies demonstrated accurate guidance of K-wire placement in pelvic bone corridors and the ability to automatically detect perturbations that degrade registration accuracy. The preclinical prototype demonstrated performance and utility supporting translation to clinical studies.
Collapse
Affiliation(s)
- Niral Sheth
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| | - Prasad Vagdargi
- Johns Hopkins University, Department of Computer Science, Baltimore, Maryland, United States
| | - Alejandro Sisniega
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| | - Ali Uneri
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| | - Gregory Osgood
- Johns Hopkins Medicine, Department of Orthopedic Surgery, Baltimore, Maryland, United States
| | - Jeffrey H. Siewerdsen
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
- Johns Hopkins University, Department of Computer Science, Baltimore, Maryland, United States
| |
Collapse
|
2
|
Vijayan RC, Han R, Wu P, Sheth NM, Ketcha MD, Vagdargi P, Vogt S, Kleinszig G, Osgood GM, Siewerdsen JH, Uneri A. Development of a fluoroscopically guided robotic assistant for instrument placement in pelvic trauma surgery. J Med Imaging (Bellingham) 2021; 8:035001. [PMID: 34124283 PMCID: PMC8189698 DOI: 10.1117/1.jmi.8.3.035001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Accepted: 05/21/2021] [Indexed: 11/14/2022] Open
Abstract
Purpose: A method for fluoroscopic guidance of a robotic assistant is presented for instrument placement in pelvic trauma surgery. The solution uses fluoroscopic images acquired in standard clinical workflow and helps avoid repeat fluoroscopy commonly performed during implant guidance. Approach: Images acquired from a mobile C-arm are used to perform 3D-2D registration of both the patient (via patient CT) and the robot (via CAD model of a surgical instrument attached to its end effector, e.g; a drill guide), guiding the robot to target trajectories defined in the patient CT. The proposed approach avoids C-arm gantry motion, instead manipulating the robot to acquire disparate views of the instrument. Phantom and cadaver studies were performed to determine operating parameters and assess the accuracy of the proposed approach in aligning a standard drill guide instrument. Results: The proposed approach achieved average drill guide tip placement accuracy of 1.57 ± 0.47 mm and angular alignment of 0.35 ± 0.32 deg in phantom studies. The errors remained within 2 mm and 1 deg in cadaver experiments, comparable to the margins of errors provided by surgical trackers (but operating without the need for external tracking). Conclusions: By operating at a fixed fluoroscopic perspective and eliminating the need for encoded C-arm gantry movement, the proposed approach simplifies and expedites the registration of image-guided robotic assistants and can be used with simple, non-calibrated, non-encoded, and non-isocentric C-arm systems to accurately guide a robotic device in a manner that is compatible with the surgical workflow.
Collapse
Affiliation(s)
- Rohan C. Vijayan
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| | - Runze Han
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| | - Pengwei Wu
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| | - Niral M. Sheth
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| | - Michael D. Ketcha
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| | - Prasad Vagdargi
- Johns Hopkins University, Department of Computer Science, Baltimore, Maryland, United States
| | | | | | - Greg M. Osgood
- Johns Hopkins Medicine, Department of Orthopaedic Surgery, Baltimore, Maryland, United States
| | - Jeffrey H. Siewerdsen
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
- Johns Hopkins University, Department of Computer Science, Baltimore, Maryland, United States
| | - Ali Uneri
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| |
Collapse
|
3
|
Vijayan RC, Han R, Wu P, Sheth NM, Vagdargi P, Vogt S, Kleinszig G, Osgood GM, Siewerdsen JH, Uneri A. Fluoroscopic Guidance of a Surgical Robot: Pre-clinical Evaluation in Pelvic Guidewire Placement. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2021; 11598:115981G. [PMID: 36090307 PMCID: PMC9455933 DOI: 10.1117/12.2582188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
PURPOSE A method and prototype for a fluoroscopically-guided surgical robot is reported for assisting pelvic fracture fixation. The approach extends the compatibility of existing guidance methods with C-arms that are in mainstream use (without prior geometric calibration) using an online calibration of the C-arm geometry automated via registration to patient anatomy. We report the first preclinical studies of this method in cadaver for evaluation of geometric accuracy. METHODS The robot is placed over the patient within the imaging field-of-view and radiographs are acquired as the robot rotates an attached instrument. The radiographs are then used to perform an online geometric calibration via 3D-2D image registration, which solves for the intrinsic and extrinsic parameters of the C-arm imaging system with respect to the patient. The solved projective geometry is then be used to register the robot to the patient and drive the robot to planned trajectories. This method is applied to a robotic system consisting of a drill guide instrument for guidewire placement and evaluated in experiments using a cadaver specimen. RESULTS Robotic drill guide alignment to trajectories defined in the cadaver pelvis were accurate within 2 mm and 1° (on average) using the calibration-free approach. Conformance of trajectories within bone corridors was confirmed in cadaver by extrapolating the aligned drill guide trajectory into the cadaver pelvis. CONCLUSION This study demonstrates the accuracy of image-guided robotic positioning without prior calibration of the C-arm gantry, facilitating the use of surgical robots with simpler imaging devices that cannot establish or maintain an offline calibration. Future work includes testing of the system in a clinical setting with trained orthopaedic surgeons and residents.
Collapse
Affiliation(s)
- R C Vijayan
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore MD USA
| | - R Han
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore MD USA
| | - P Wu
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore MD USA
| | - N M Sheth
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore MD USA
| | - P Vagdargi
- Department of Computer Science, Johns Hopkins University, Baltimore MD USA
| | - S Vogt
- Siemens Healthineers, Erlangen Germany
| | | | - G M Osgood
- Department of Orthopaedic Surgery, Johns Hopkins University, Baltimore MD USA
| | - J H Siewerdsen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore MD USA
- Department of Computer Science, Johns Hopkins University, Baltimore MD USA
| | - A Uneri
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore MD USA
| |
Collapse
|