• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4594740)   Today's Articles (11)   Subscriber (49325)
For: Sundaram P, Beaulieu CF, Paik DS, Schraedley-Desmond P, Napel S. CT colonography: Does improvedzresolution help computer-aided polyp detection? Med Phys 2003;30:2663-74. [PMID: 14596303 DOI: 10.1118/1.1599985] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
Number Cited by Other Article(s)
1
Kim SH, Lee JM, Shin CI, Kim HC, Lee JG, Kim JH, Choi JY, Eun HW, Han JK, Lee JY, Choi BI. Effects of Spatial Resolution and Tube Current on Computer-aided Detection of Polyps on CT Colonographic Images: Phantom Study. Radiology 2008;248:492-503. [DOI: 10.1148/radiol.2482071025] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
2
Performance of a Previously Validated CT Colonography Computer-Aided Detection System in a New Patient Population. AJR Am J Roentgenol 2008;191:168-74. [DOI: 10.2214/ajr.07.3354] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
3
Sundaram P, Zomorodian A, Beaulieu C, Napel S. Colon polyp detection using smoothed shape operators: preliminary results. Med Image Anal 2007;12:99-119. [PMID: 17910934 DOI: 10.1016/j.media.2007.08.001] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2007] [Revised: 07/25/2007] [Accepted: 08/03/2007] [Indexed: 10/22/2022]
4
Boedeker KL, McNitt-Gray MF. Application of the noise power spectrum in modern diagnostic MDCT: part II. Noise power spectra and signal to noise. Phys Med Biol 2007;52:4047-61. [PMID: 17664594 DOI: 10.1088/0031-9155/52/14/003] [Citation(s) in RCA: 82] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
5
Chowdhury TA, Whelan PF, Ghita O, Sezille N, Foley S. Development of a synthetic phantom for the selection of optimal scanning parameters in CAD-CT colonography. Med Eng Phys 2006;29:858-67. [PMID: 17097327 DOI: 10.1016/j.medengphy.2006.09.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2005] [Revised: 09/13/2006] [Accepted: 09/19/2006] [Indexed: 01/22/2023]
6
Yoshida H, Dachman AH. CAD techniques, challenges, and controversies in computed tomographic colonography. ACTA ACUST UNITED AC 2005;30:26-41. [PMID: 15647868 DOI: 10.1007/s00261-004-0244-x] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA