1
|
İpek ŞC, Tunç M, Oysul K, Yaman A, Saatci AO. CyberKnife Stereotactic Radiotherapy in Secondary Vasoproliferative Tumor of the Retina. Case Rep Ophthalmol 2021; 12:264-269. [PMID: 34054468 PMCID: PMC8138144 DOI: 10.1159/000513109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Accepted: 11/14/2020] [Indexed: 11/19/2022] Open
Abstract
A 16-year-old boy with X-linked retinoschisis was examined for the visual decline on his left eye. Upon examination, a vasopermeable elevated mass lesion was determined at the lower temporal retinal periphery associated with surrounding arc-like hard exudates which is consistent with a vasoactive proliferative tumor of the retina. After discussing the therapeutic options with the patient and his parents, 3 successive dexamethasone implants 6 months apart were administered. As no satisfactory regression was noticed, CyberKnife stereotactic radiosurgery (SRS) was performed. Regression of the exudative tumor was obtained in follow-up examinations at 12 and 24 months after the SRS session and the thickness of the lesion was markedly reduced.
Collapse
Affiliation(s)
- Şefik Can İpek
- Department of Ophthalmology, Ağrı Research and Training Hospital, Ağrı, Turkey
| | - Murat Tunç
- Department of Ophthalmology, Tunç Eye Clinic, Ankara, Turkey
| | - Kaan Oysul
- Department of Radiation Oncology, Medicana Hospital, Ankara, Turkey
| | - Aylin Yaman
- Department of Ophthalmology, Dokuz Eylul University, Izmir, Turkey
| | - Ali Osman Saatci
- Department of Ophthalmology, Dokuz Eylul University, Izmir, Turkey
| |
Collapse
|
2
|
Agarwal A, Raghavan V, Rathnadevi R, Rishi P. Treatment of circumscribed choroidal hemangioma using CyberKnife: A viable alternative. Indian J Ophthalmol 2019; 67:704-706. [PMID: 31007252 PMCID: PMC6498904 DOI: 10.4103/ijo.ijo_1410_18] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Circumscribed choroidal hemangioma is a benign vascular hamartoma without systemic associations. For symptomatic cases, treatment options are photodynamic therapy (PDT), transpupillary thermotherapy (TTT), intravitreal injection of anti-vascular endothelial growth factor (VEGF), or radiation therapy. CyberKnife radiosurgery is an image-guided radiation therapy that delivers radiation to lesions anywhere in the body with an accuracy of 0.5 mm without damage to surrounding structures. We report a case of circumscribed choroidal hemangioma which was successfully treated with CyberKnife therapy. The literature search reveals cases of uveal melanoma, intraocular, and periocular lymphoma successfully treated with CyberKnife therapy. To the best of our knowledge, this is the first report on such treatment for choroidal hemangioma.
Collapse
Affiliation(s)
- Aditi Agarwal
- Shree Bhagwan Mahavir Vitreoretinal Services Department, Sankara Nethralaya, College Road, Nungambakkam, Tamil Nadu, India
| | - Venkatavaradan Raghavan
- Shree Bhagwan Mahavir Vitreoretinal Services Department, Sankara Nethralaya, College Road, Nungambakkam, Tamil Nadu, India
| | - Ramadas Rathnadevi
- Department of Radiation Oncology and Cyberknife Services, Apollo Hospitals, Teynampet, Chennai, Tamil Nadu, India
| | - Pukhraj Rishi
- Shree Bhagwan Mahavir Vitreoretinal Services Department, Sankara Nethralaya, College Road, Nungambakkam, Tamil Nadu, India
| |
Collapse
|
3
|
A pilot study on geometrical uncertainties for intra ocular cancers in radiotherapy. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2017; 40:433-439. [PMID: 28466444 DOI: 10.1007/s13246-017-0551-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2016] [Accepted: 04/14/2017] [Indexed: 10/19/2022]
Abstract
A system for stabilising and monitoring eye movements for linac-based stereotactic radiotherapy associated with the mobile eye, the Eye Tracker, was developed. Whilst the Eye Tracker design is based on a previously reported system, the purpose of this study was to confirm that the modified version can be used with clinically acceptable treatment margins. We report the estimates of the margin required to account for inter- and intra-fraction eye motion based on data from 12 consecutive patients treated with the Eye Tracker system in place. Patients were immobilised in a head and neck mask and were required to fixate on a light source. A camera system monitored eye movements relative to CT simulation baseline measurements. The Exactrac system (Brainlab, Feldkirchen, Germany) combined with the Varian TrueBeamSTx (Varian Medical Systems, Palo Alto, CA) confirmed pre- and intra-treatment setup of the head position. Displacement/rotation of the image of the pupil/iris was determined in the lateral and superior-inferior directions using a video display. A standard margin equation was applied to estimate the margin required to account for inter- and intra-fraction eye movement. The average displacement in both directions was 0.1-0.2 mm (0.36 mm SD). All patients maintained a position within 1 mm of the intended position during treatment. Based on a Bayesian estimation of the systematic and treatment errors, accounting for displacements in two-planes and a standard deviation of the penumbral width of 1.3 mm, the estimated margins to achieve coverage of the GTV with the 95% isodose in 90% of patients was found to be less than 1 mm. Small random and systematic uncertainties due to inter- and intra-fraction movement of the eye were achieved with the Eye Tracker. Whilst the estimated margins are small (<1 mm) they need to be considered in addition to contouring and treatment delivery uncertainties.
Collapse
|
4
|
Inoue T, Masai N, Shiomi H, Oh RJ, Uemoto K, Hashida N. Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma. JOURNAL OF RADIATION RESEARCH 2017; 58:386-396. [PMID: 27811199 PMCID: PMC5440859 DOI: 10.1093/jrr/rrw104] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/04/2016] [Revised: 06/05/2016] [Accepted: 09/30/2016] [Indexed: 06/06/2023]
Abstract
We aimed to describe the feasibility and efficacy of a novel non-invasive fixation and monitoring (F-M) device for the eyeballs (which uses a right-angle prism mirror as the optic axis guide) in three consecutive patients with choroidal melanoma who were treated with intensity-modulated radiotherapy (IMRT). The device consists of an immobilization shell, a right-angle prism mirror, a high magnification optical zoom video camera, a guide lamp, a digital voice recorder, a personal computer, and a National Television System Committee standard analog video cable. Using the right-angle prism mirror, the antero-posterior axis was determined coincident with the optic axis connecting the centers of the cornea and pupil. The axis was then connected to the guide light and video camera installed on the couch top on the distal side. Repositioning accuracy improved using this method. Furthermore, the positional error of the lens was markedly reduced from ±1.16, ±1.68 and ±1.11 mm to ±0.23, ±0.58 and ±0.26 mm in the horizontal direction, and from ±1.50, ±1.03 and ±0.48 mm to ±0.29, ±0.30 and ±0.24 mm in the vertical direction (Patient #1, #2 and #3, respectively). Accordingly, the F-M device method decreased the planning target volume size and improved the dose-volume histogram parameters of the organ-at-risk via IMRT inverse planning. Importantly, the treatment method was well tolerated.
Collapse
Affiliation(s)
- Toshihiko Inoue
- Miyakojima IGRT Clinic, 1-16-22, Miyakojimahondori, Miyakojima-ku, 534-0021, Japan
| | - Norihisa Masai
- Miyakojima IGRT Clinic, 1-16-22, Miyakojimahondori, Miyakojima-ku, 534-0021, Japan
| | - Hiroya Shiomi
- Miyakojima IGRT Clinic, 1-16-22, Miyakojimahondori, Miyakojima-ku, 534-0021, Japan
| | - Ryoong-Jin Oh
- Miyakojima IGRT Clinic, 1-16-22, Miyakojimahondori, Miyakojima-ku, 534-0021, Japan
| | - Kenji Uemoto
- Miyakojima IGRT Clinic, 1-16-22, Miyakojimahondori, Miyakojima-ku, 534-0021, Japan
| | - Noriyasu Hashida
- Department of Ophthalmology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| |
Collapse
|
5
|
Iskanderani O, Béliveau-Nadeau D, Doucet R, Coulombe G, Pascale D, Roberge D. Reproducibility of a Noninvasive System for Eye Positioning and Monitoring in Stereotactic Radiotherapy of Ocular Melanoma. Technol Cancer Res Treat 2017; 16:352-356. [PMID: 28168935 PMCID: PMC5616051 DOI: 10.1177/1533034617690979] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Purpose: Our preferred treatment for juxtapapillary choroidal melanoma is stereotactic radiotherapy. We aim to describe our immobilization system and quantify its reproducibility. Materials and Methods: Patients were identified in our radiosurgery database. Patients were imaged at computed tomography simulator with an in-house system which allows visual monitoring of the eye as the patient fixates a small target. All patients were reimaged at least once prior to and/or during radiotherapy. The patients were treated on the CyberKnife system, 60 Gy in 10 daily fractions, using skull tracking in conjunction with our visual monitoring system. In order to quantify the reproducibility of the eye immobilization system, computed tomography scans were coregistered using rigid 6-dimensional skull registration. Using the coregistered scans, x, y, and z displacements of the lens/optic nerve insertion were measured. From these displacements, 3-dimensional vectors were calculated. Results: Thirty-four patients were treated from October 2010 to September 2015. Thirty-nine coregistrations were performed using 73 scans (2-3 scans per patient). The mean displacements of lens and optic nerve insertion were 0.1 and 0.0 mm. The median 3-dimensional displacements (absolute value) of lens and nerve insertion were 0.8 and 0.7 mm (standard deviation: 0.5 and 0.6 mm). Ninety-eight percent of 3-dimensional displacements were below 2 mm (maximum 2.4 mm). The calculated planning target volume (PTV) margins were 0.8, 1.4, and 1.5 mm in the anterior–posterior, craniocaudal, and right–left axes, respectively. Following this analysis, no further changes have been applied to our planning margin of 2 to 2.5 mm as it is also meant to account for uncertainties in magnetic resonance imaging to computed tomography registration, skull tracking, and also contouring variability. Conclusion: We have found our stereotactic eye immobilization system to be highly reproducible (<1 mm) and free of systematic error.
Collapse
Affiliation(s)
- Omar Iskanderani
- 1 Department of Radiation Oncology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Québec, Canada.,2 Department of Radiation Oncology, King Abdulaziz University Hospital, Jeddah, Saudi Arabia
| | - Dominique Béliveau-Nadeau
- 1 Department of Radiation Oncology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Québec, Canada
| | - Robert Doucet
- 1 Department of Radiation Oncology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Québec, Canada
| | - Geneviève Coulombe
- 1 Department of Radiation Oncology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Québec, Canada
| | - Deborah Pascale
- 1 Department of Radiation Oncology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Québec, Canada
| | - David Roberge
- 1 Department of Radiation Oncology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Québec, Canada
| |
Collapse
|
6
|
Adamczyk M, Janiga P. Staged Radiosurgical Ablation for Choroid Melanoma: A Case Report with Emphasis on the Role of Patient Preparation, Treatment Planning, and Precision of Delivery. Cureus 2016; 8:e611. [PMID: 27335716 PMCID: PMC4911270 DOI: 10.7759/cureus.611] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
The aim of reporting this case of choroid melanoma of the left eye is to introduce the in-house-designed treatment planning protocol for fractionated radiosurgical ablation of an intraocular lesion. This is a clinical case with emphasis on treatment preparation and delivery using the Accuray CyberKnife Robotic Radiosurgery System (Accuray, Sunnyvale, CA, USA) for a patient immobilized with a head mask and our in-house-made eye fixation system.
Collapse
Affiliation(s)
- Marta Adamczyk
- Medical Physics Department, Greater Poland Cancer Centre
| | - Piotr Janiga
- Radiotherapy Ward I, Greater Poland Cancer Centre
| |
Collapse
|
7
|
Béliveau-Nadeau D, Callejo S, Roberge D. Technique for Robotic Stereotactic Irradiation of Choroidal Melanoma. Cureus 2016; 8:e582. [PMID: 27226942 PMCID: PMC4876010 DOI: 10.7759/cureus.582] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Radiotherapy has a long history in the organ-sparing management of choroidal melanoma. Joining plaque radiotherapy and proton irradiation, stereotactic robotic photon irradiation is a new tool in the radiation oncologist's armamentarium for ocular tumors. The non-coplanar fields with steep dose gradients are well suited to spare uninvolved retina, anterior chamber, and the optic nerve. In our practice, it is the preferred treatment for melanomas that are non-amenable to standard plaque brachytherapy. Since late 2010, we have treated more than 40 patients with our robotic linear accelerator. This case-based technical note outlines the technique used at the University of Montreal, Montreal, Canada.
Collapse
Affiliation(s)
| | - Sonia Callejo
- Department of Ophthalmology, Centre hospitalier de l'université de Montréal (CHUM)
| | - David Roberge
- Department of Oncology, Division of Radiation Oncology, McGill University Health Center ; Department of Radiology, Radiation Oncology and Nuclear Medicine, University of Montreal ; Department of Radiation Oncology, Centre hospitalier de l'université de Montréal (CHUM) ; Department of Oncology, Division of Radiation Oncology, McGill University Health Center
| |
Collapse
|
8
|
Klingenstein A, Kufeld M, Wowra B, Muacevic A, Fürweger C, Schaller UC. CyberKnife radiosurgery for the treatment of orbital metastases. Technol Cancer Res Treat 2012; 11:433-9. [PMID: 22475063 DOI: 10.7785/tcrt.2012.500257] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Purpose of this study is to evaluate radiographic therapy response, clinical outcome and adverse effects of CyberKnife radiosurgery in patients suffering from orbital metastases. Sixteen orbital metastases originating from different solid cancers in fourteen patients were treated by single fraction CyberKnife radiosurgery. Radiographic response and clinical outcome were evaluated. The treated tumor volume ranged from 0.2 to 35 cm3 (median 2.3 cm3, mean 7.0 cm3, SD 6 10.4 cm3, CI 0.9-9.4 cm3). The prescription dose ranged from 16.5-21 Gy (median 18 Gy, mean 18.2 Gy, SD 6 1.2 Gy, CI 17.0-18.4 Gy). A no change situation was observed in nine lesions, partial remission in four as well as complete remission in one metastasis. Tumor growth was stabilized or regressive following CyberKnife therapy in 87% of the cases. Recurrence was observed in two cases (13%). Before therapy, three patients suffered from visual disturbance and five patients reported diplopia. Six patients had no initial symptoms. After therapy, one patient indicated improvement of the present visual deficit and two patients no change. Out of the two patients with persistent diplopia, two reported improvement after therapy and three no change. No progression of symptoms was noted in any of the cases. Fourteen out of sixteen treated lesions were stable or regressive following CyberKnife radiosurgery (87%). As no serious adverse effects were reported in this series, CyberKnife therapy was shown to be of great value for local management of orbital metastases.
Collapse
Affiliation(s)
- A Klingenstein
- Department of Ophthalmology, Ludwig-Maximilians-University, Klinikum der Universitat Munchen, Munich, Germany.
| | | | | | | | | | | |
Collapse
|
9
|
Chen CJ, McCoy AN, Brahmer J, Handa JT. Emerging treatments for choroidal metastases. Surv Ophthalmol 2012; 56:511-21. [PMID: 22117885 DOI: 10.1016/j.survophthal.2011.05.001] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2010] [Revised: 05/13/2011] [Accepted: 05/17/2011] [Indexed: 11/17/2022]
Abstract
It has been over a century since Perls described the first case of choroidal metastasis. For the next six decades only 230 cases were described in the literature. Today, however, ocular metastasis is recognized as the most common intraocular malignancy. Thanks to recent advances in treatment options for metastatic disease, patients are living longer, and choroidal metastases will become an increasingly important issue for oncologists and ophthalmologists alike. We summarize the current knowledge of choroidal metastases and examine their emerging systemic and local therapies. Targeted therapies for metastatic lung, breast, and colon cancer--the most common causes of choroidal metastases--are reviewed in detail with the goal of identifying the most effective treatment strategies.
Collapse
Affiliation(s)
- Connie J Chen
- Wilmer Eye Institute, Johns Hopkins School of Medicine, Baltimore, Maryland, USA
| | | | | | | |
Collapse
|