Shiha M, Cygler JE, MacRae R, Heath E. 4D Monte Carlo dose reconstructions using surface motion measurements. Phys Med 2023; 114:103135. [PMID: 37738806 DOI: 10.1016/j.ejmp.2023.103135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 08/01/2023] [Accepted: 09/13/2023] [Indexed: 09/24/2023] Open
Abstract
PURPOSE To investigate the feasibility of a 4D Monte Carlo based dose reconstruction method to study the dosimetric impact of respiratory motion using surface motion measurements for patients undergoing VMAT treatments for Non-Small Cell Lung Cancer. METHODS The 4Ddefdosxyznrc/EGSnrc algorithm was used to reconstruct VMAT doses delivered to the patients using machine log files and respiratory traces measured with the RADPOS 4D dosimetry system. The RADPOS sensor was adhered to the patient's abdomen prior to each treatment fraction and its position was used as a surrogate for tumour motion. Treatment log files were synchronized with the patient respiratory traces. Patient specific respiratory models were generated from deformable registration of the inhale and exhale 4DCT images and the respiratory traces. The reconstructed doses were compared to planned doses calculated with DOSXYZnrc/EGSnrc on the average-intensity and the exhale phase CT images. RESULTS Respiratory motion measurements and log files were acquired for 2 patients over 5 treatment fractions each. The motion was predominantly along the anterior/posterior direction (A/P). The average respiratory amplitudes were 8.7 ± 2.7 mm and 10.0 ± 1.2 mm for Patient 1 and 2, respectively. Both patients displayed inter- and intra-fractional variations in the baseline position. Small inter-fractional differences were observed in the reconstructed doses for each patient. Differences between the reconstructed and planned doses were attributed to differences in organ volumes. CONCLUSION The 4D reconstruction method was successfully implemented for the two patients studied. Small differences between the planned and reconstructed doses were observed due to the small tumour motion of these patients.
Collapse
Affiliation(s)
- Meaghen Shiha
- Department of Physics, Carleton University, Ottawa, ON K1S 5B6, Canada.
| | - Joanna E Cygler
- Department of Physics, Carleton University, Ottawa, ON K1S 5B6, Canada; Department of Medical Physics, The Ottawa Hospital Cancer Centre, Ottawa, ON K1H 8L6, Canada; Department of Radiology, University of Ottawa, Ottawa, ON K1H 8L6, Canada
| | - Robert MacRae
- Department of Radiology, Division of Radiation Oncology, University of Ottawa, 501 Smyth Road, Ottawa, ON K1H8L6, Canada
| | - Emily Heath
- Department of Physics, Carleton University, Ottawa, ON K1S 5B6, Canada
| |
Collapse
|
2
|
Gholampourkashi S, Cygler JE, Lavigne B, Heath E. Validation of 4D Monte Carlo dose calculations using a programmable deformable lung phantom. Phys Med 2020; 76:16-27. [PMID: 32569953 DOI: 10.1016/j.ejmp.2020.05.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 04/17/2020] [Accepted: 05/31/2020] [Indexed: 10/24/2022] Open
Abstract
PURPOSE To validate the accuracy of 4D Monte Carlo (4DMC) simulations to calculate dose deliveries to a deforming anatomy in the presence of realistic respiratory motion traces. A previously developed deformable lung phantom comprising an elastic tumor was modified to enable programming of arbitrary motion profiles. 4D simulations of the dose delivered to the phantom were compared with the measurements. METHODS The deformable lung phantom moving with irregular breathing patterns was irradiated using static and VMAT beam deliveries. Using the RADPOS 4D dosimetry system, point doses were measured inside and outside the tumor. Dose profiles were acquired using films along the motion path of the tumor (S-I). In addition to dose measurements, RADPOS was used to record the motion of the tumor during dose deliveries. Dose measurements were then compared against 4DMC simulations with EGSnrc/4DdefDOSXYZnrc using the recorded tumor motion. RESULTS The agreements between dose profiles from measurements and simulations were determined to be within 2%/2 mm. Point dose agreements were within 2σ of experimental and/or positional/dose reading uncertainties. 4DMC simulations were shown to accurately predict the sensitivity of delivered dose to the starting phase of breathing motions. We have demonstrated that our 4DMC method, combined with RADPOS, can accurately simulate realistic dose deliveries to a deforming anatomy moving with realistic breathing traces. This 4DMC tool has the potential to be used as a quality assurance tool to verify treatments involving respiratory motion. Adaptive treatment delivery is another area that may benefit from the potential of this 4DMC tool.
Collapse
Affiliation(s)
- Sara Gholampourkashi
- Department of Physics, Carleton University, Ottawa, ON, Canada; Department of Medical Physics, The Ottawa Hospital Cancer Center, Ottawa, ON, Canada.
| | - Joanna E Cygler
- Department of Physics, Carleton University, Ottawa, ON, Canada; Department of Medical Physics, The Ottawa Hospital Cancer Center, Ottawa, ON, Canada
| | - Bernie Lavigne
- Department of Medical Physics, The Ottawa Hospital Cancer Center, Ottawa, ON, Canada
| | - Emily Heath
- Department of Physics, Carleton University, Ottawa, ON, Canada
| |
Collapse
|
3
|
Kostiukhina N, Palmans H, Stock M, Knopf A, Georg D, Knäusl B. Time-resolved dosimetry for validation of 4D dose calculation in PBS proton therapy. Phys Med Biol 2020; 65:125015. [PMID: 32340002 DOI: 10.1088/1361-6560/ab8d79] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Four-dimensional dose calculation (4D-DC) is crucial for predicting the dosimetric outcome in the presence of intra-fractional organ motion. Time-resolved dosimetry can provide significant insights into 4D pencil beam scanning dose accumulation and is therefore irreplaceable for benchmarking 4D-DC. In this study a novel approach of time-resolved dosimetry using five PinPoint ionization chambers (ICs) embedded in an anthropomorphic dynamic phantom was employed and validated against beam delivery details. Beam intensity variations as well as the beam delivery time structure were well reflected with an accuracy comparable to the temporal resolution of the IC measurements. The 4D dosimetry approach was further applied for benchmarking the 4D-DC implemented in the RayStation 6.99 treatment planning system. Agreement between computed values and measurements was investigated for (i) partial doses based on individual breathing phases, and (ii) temporally distributed cumulative doses. For varied beam delivery and patient-related parameters the average unsigned dose difference for (i) was 0.04 ± 0.03 Gy over all considered IC measurement values, while the prescribed physical dose was 2 Gy. By implementing (ii), a strong effect of the dose gradient on measurement accuracy was observed. The gradient originated from scanned beam energy modulation and target motion transversal to the beam. Excluding measurements in the high gradient the relative dose difference between measurements and 4D-DCs for a given treatment plan at the end of delivery was 3.5% on average and 6.6% at maximum over measurement points inside the target. Overall, the agreement between 4D dose measurements in the moving phantom and retrospective 4D-DC was found to be comparable to the static dose differences for all delivery scenarios. The presented 4D-DC has been proven to be suitable for simulating treatment deliveries with various beam- as well as patient-specific parameters and can therefore be employed for dosimetric validation of different motion mitigation techniques.
Collapse
Affiliation(s)
- N Kostiukhina
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna/AKH Vienna, Vienna, Austria. Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | | | | | | | | | | |
Collapse
|
4
|
Tho D, Beaulieu L. Technical Note: Identification of an optimal electromagnetic sensor for
in vivo
electromagnetic‐tracked scintillation dosimeter for HDR brachytherapy. Med Phys 2019; 46:2031-2036. [DOI: 10.1002/mp.13508] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Revised: 02/15/2018] [Accepted: 03/04/2018] [Indexed: 11/09/2022] Open
Affiliation(s)
- Daline Tho
- Département de radio‐oncologie et Centre de recherche du CHU de Québec CHU de Québec Québec Canada
- Département de physique, de génie physique et d'optique, et Centre de recherche sur le cancer Université Laval Québec Canada
| | - Luc Beaulieu
- Département de radio‐oncologie et Centre de recherche du CHU de Québec CHU de Québec Québec Canada
- Département de physique, de génie physique et d'optique, et Centre de recherche sur le cancer Université Laval Québec Canada
| |
Collapse
|
5
|
Marants R, Vandervoort E, Cygler JE. Evaluation of the 4D RADPOS dosimetry system for dose and position quality assurance of CyberKnife. Med Phys 2018; 45:4030-4044. [PMID: 30043980 DOI: 10.1002/mp.13102] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2018] [Revised: 07/09/2018] [Accepted: 07/10/2018] [Indexed: 02/28/2024] Open
Abstract
PURPOSE The Synchrony respiratory motion tracking of the CyberKnife system purports to provide real-time tumor motion compensation during robotic radiosurgery. Such a complex delivery system requires thorough quality assurance. In this work, RADPOS applicability as a dose and position quality assurance tool for CyberKnife treatments is assessed quantitatively for different phantom types and breathing motions, which increase in complexity to more closely resemble clinical situations. METHODS Two radiotherapy treatment experiments were performed where dose and position were measured with the RADPOS probe housed within a Solid Water phantom. For the first experiment, a Solid Water breast phantom was irradiated using isocentric beam delivery while stationary or moving sinusoidally in the anterior/posterior direction. For the second experiment, a phantom consisting of a Solid Water tumor in lung equivalent material was irradiated using isocentric and non-isocentric beam delivery while either stationary or moving. The phantom movement was either sinusoidal or based on a real patient's breathing waveform. For each experiment, RADPOS dose measurements were compared to EBT3 GafChromic film dose measurements and the CyberKnife treatment planning system's (TPS) Monte Carlo and ray-tracing dose calculation algorithms. RADPOS position measurements were compared to measurements made by the CyberKnife system and to the predicted breathing motion models used by the Synchrony respiratory motion compensation. RESULTS For the static and dynamic (i.e., sinusoidal motion) cases of the breast experiment, RADPOS, film and the TPS agreed at the 2.0% level within 1.1 σ of estimated combined uncertainties. RADPOS position measurements were in good agreement with LED and fiducial position measurements, where the average standard deviation (SD) of the differences between any two of the three position datasets was ≤0.5 mm for all directions. For the 10 mm peak to peak amplitude sinusoidal motion of the breast experiment, the average Synchrony correlation errors were ≤0.2 mm, indicative of an accurate predictive model. For all the cases of the lung experiment, RADPOS and film measurements agreed with each other at the 2.0% level within 1.5 σ of estimated experimental uncertainties provided that the measurements were corrected for imaging dose. The measured dose for RADPOS and film were 4.0% and 3.4% higher, respectively, than the TPS for the most complex dynamic cases (i.e., irregular motion) considered for the lung experiment. Assessment of the Synchrony correlation models by RADPOS showed that model accuracy declined as motion complexity increased; the SD of the differences between RADPOS and model position data measurements was ≤0.8 mm for sinusoidal motion but increased to ≤2.6 mm for irregular patient waveform motion. These results agreed with the Synchrony correlation errors reported by the CyberKnife system. CONCLUSIONS RADPOS is an accurate and precise QA tool for dose and position measurements for CyberKnife deliveries with respiratory motion compensation.
Collapse
Affiliation(s)
- Raanan Marants
- Department of Physics, Carleton University, Ottawa, ON, K1S 5B6, Canada
| | - Eric Vandervoort
- Department of Physics, Carleton University, Ottawa, ON, K1S 5B6, Canada
- Department of Medical Physics, The Ottawa Hospital Cancer Centre, Ottawa, ON, K1H 8L6, Canada
| | - Joanna E Cygler
- Department of Physics, Carleton University, Ottawa, ON, K1S 5B6, Canada
- Department of Medical Physics, The Ottawa Hospital Cancer Centre, Ottawa, ON, K1H 8L6, Canada
| |
Collapse
|
6
|
Development of a deformable phantom for experimental verification of 4D Monte Carlo simulations in a deforming anatomy. Phys Med 2018; 51:81-90. [DOI: 10.1016/j.ejmp.2018.05.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2017] [Revised: 05/09/2018] [Accepted: 05/10/2018] [Indexed: 12/25/2022] Open
|
7
|
Assessment of the implant geometry in fractionated interstitial HDR breast brachytherapy using an electromagnetic tracking system. Brachytherapy 2017; 17:94-102. [PMID: 29146103 DOI: 10.1016/j.brachy.2017.10.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 09/17/2017] [Accepted: 10/13/2017] [Indexed: 11/20/2022]
Abstract
PURPOSE During the partial-breast treatment course by interstitial brachytherapy, electromagnetic tracking (EMT) was applied to measure the implant geometry. Implant-geometry variation, choice of reference data, and three registration methods were assessed. METHODS AND MATERIALS The implant geometry was measured in 28 patients after catheter implantation (EMTbed), during CT imaging (EMTCT), and in each of up to n = 9 treatment fractions (EMTF(k), k = 1, 2,… n). EMTF(k) were registered to the planned implant reconstruction (CTplan) by using all dwell positions (DPs), the button centers, or three fiducial sensors on the patient's skin. Variation in implant geometry obtained from EMTF(k) was assessed for EMTbed, EMTCT, and CTplan. RESULTS EMT was used to measure 3932 catheters. A duration of 6.5 ± 1.7 min was needed for each implant measurement (mean, 17 catheters) plus setup of the EMT system. Data registration based on the DP deviated significantly lower than registration on button centers or fiducial sensors. Within a registration group, there was a <0.5-mm difference in the choice of reference data. Using CTplan as reference for registration, the mean residual distance of DPs on EMT-derived DPs was found at 2.1 ± 1.6 mm (EMTbed), 1.3 ± 0.9 mm (EMTCT), and 2.5 ± 1.5 mm (EMTF(k)). CONCLUSIONS EMT can assess the implant geometry in high-dose-rate interstitial brachytherapy breast treatments. EMTbed, EMTCT, and CTplan data can serve as reference for assessment of implant changes.
Collapse
|
8
|
Cygler JE, Gholampourkashi S, Heath E. Abstract ID: 15 Experimental verification of 4D Monte Carlo calculations of dose delivered to a deforming anatomy. Phys Med 2017. [DOI: 10.1016/j.ejmp.2017.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
9
|
Kellermeier M, Herbolzheimer J, Kreppner S, Lotter M, Strnad V, Bert C. Electromagnetic tracking (EMT) technology for improved treatment quality assurance in interstitial brachytherapy. J Appl Clin Med Phys 2017; 18:211-222. [PMID: 28291934 PMCID: PMC5689872 DOI: 10.1002/acm2.12021] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2016] [Accepted: 10/27/2016] [Indexed: 11/09/2022] Open
Abstract
Electromagnetic Tracking (EMT) is a novel technique for error detection and quality assurance (QA) in interstitial high dose rate brachytherapy (HDR-iBT). The purpose of this study is to provide a concept for data acquisition developed as part of a clinical evaluation study on the use of EMT during interstitial treatment of breast cancer patients. The stability, accuracy, and precision of EMT-determined dwell positions were quantified. Dwell position reconstruction based on EMT was investigated on CT table, HDR table and PDR bed to examine the influence on precision and accuracy in a typical clinical workflow. All investigations were performed using a precise PMMA phantom. The track of catheters inserted in that phantom was measured by manually inserting a 5 degree of freedom (DoF) sensor while recording the position of three 6DoF fiducial sensors on the phantom surface to correct motion influences. From the corrected data, dwell positions were reconstructed along the catheter's track. The accuracy of the EMT-determined dwell positions was quantified by the residual distances to reference dwell positions after using a rigid registration. Precision and accuracy were investigated for different phantom-table and sensor-field generator (FG) distances. The measured precision of the EMT-determined dwell positions was ≤ 0.28 mm (95th percentile). Stability tests showed a drift of 0.03 mm in the first 20 min of use. Sudden shaking of the FG or (large) metallic objects close to the FG degrade the precision. The accuracy with respect to the reference dwell positions was on all clinical tables < 1 mm at 200 mm FG distance and 120 mm phantom-table distance. Phantom measurements showed that EMT-determined localization of dwell positions in HDR-iBT is stable, precise, and sufficiently accurate for clinical assessment. The presented method may be viable for clinical applications in HDR-iBT, like implant definition, error detection or quantification of uncertainties. Further clinical investigations are needed.
Collapse
Affiliation(s)
- Markus Kellermeier
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054, Erlangen, Germany
| | - Jens Herbolzheimer
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054, Erlangen, Germany
| | - Stephan Kreppner
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054, Erlangen, Germany
| | - Michael Lotter
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054, Erlangen, Germany
| | - Vratislav Strnad
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054, Erlangen, Germany
| | - Christoph Bert
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054, Erlangen, Germany
| |
Collapse
|
10
|
Gholampourkashi S, Vujicic M, Belec J, Cygler JE, Heath E. Experimental verification of 4D Monte Carlo simulations of dose delivery to a moving anatomy. Med Phys 2017; 44:299-310. [DOI: 10.1002/mp.12023] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2016] [Revised: 11/02/2016] [Accepted: 11/07/2016] [Indexed: 12/25/2022] Open
Affiliation(s)
- Sara Gholampourkashi
- Carleton Laboratory for Radiotherapy Physics; Carleton University; 1125 Colonel By Drive Ottawa ON K1S 5B6 Canada
| | - Miro Vujicic
- Department of Medical Physics; The Ottawa Hospital Cancer Centre; 501 Smyth Road, Box 927 Ottawa ON K1H 8L6 Canada
| | - Jason Belec
- Department of Medical Physics; The Ottawa Hospital Cancer Centre; 501 Smyth Road, Box 927 Ottawa ON K1H 8L6 Canada
| | - Joanna E. Cygler
- Carleton Laboratory for Radiotherapy Physics; Carleton University; 1125 Colonel By Drive Ottawa ON K1S 5B6 Canada
- Department of Medical Physics; The Ottawa Hospital Cancer Centre; 501 Smyth Road, Box 927 Ottawa ON K1H 8L6 Canada
| | - Emily Heath
- Carleton Laboratory for Radiotherapy Physics; Carleton University; 1125 Colonel By Drive Ottawa ON K1S 5B6 Canada
| |
Collapse
|
11
|
Electromagnetic tracking for treatment verification in interstitial brachytherapy. J Contemp Brachytherapy 2016; 8:448-453. [PMID: 27895688 PMCID: PMC5116452 DOI: 10.5114/jcb.2016.63356] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2016] [Accepted: 10/04/2016] [Indexed: 11/29/2022] Open
Abstract
Electromagnetic tracking (EMT) is used in several medical fields to determine the position and orientation of dedicated sensors, e.g., attached to surgical tools. Recently, EMT has been introduced to brachytherapy for implant reconstruction and error detection. The manuscript briefly summarizes the main issues of EMT and error detection in brachytherapy. The potential and complementarity of EMT as treatment verification technology will be discussed in relation to in vivo dosimetry and imaging.
Collapse
|
12
|
Chamberland M, McEwen MR, Xu T. Technical aspects of real time positron emission tracking for gated radiotherapy. Med Phys 2016; 43:783-95. [PMID: 26843241 DOI: 10.1118/1.4939664] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
PURPOSE Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy. METHODS The tracking system, called PeTrack, uses implanted positron emission markers and position sensitive gamma ray detectors to track breathing motion in real time. PeTrack uses an expectation-maximization algorithm to track the motion of fiducial markers. A normalized least mean squares adaptive filter predicts the location of the markers a short time ahead to account for system response latency. The precision and data collection efficiency of a prototype PeTrack system were measured under conditions simulating gated radiotherapy. The lung insert of a thorax phantom was translated in the inferior-superior direction with regular sinusoidal motion and simulated patient breathing motion (maximum amplitude of motion ±10 mm, period 4 s). The system tracked the motion of a (22)Na fiducial marker (0.34 MBq) embedded in the lung insert every 0.2 s. The position of the was marker was predicted 0.2 s ahead. For sinusoidal motion, the equation used to model the motion was fitted to the data. The precision of the tracking was estimated as the standard deviation of the residuals. Software was also developed to communicate with a Linac and toggle beam delivery. In a separate experiment involving a Linac, 500 monitor units of radiation were delivered to the phantom with a 3 × 3 cm photon beam and with 6 and 10 MV accelerating potential. Radiochromic films were inserted in the phantom to measure spatial dose distribution. In this experiment, the period of motion was set to 60 s to account for beam turn-on latency. The beam was turned off when the marker moved outside of a 5-mm gating window. RESULTS The precision of the tracking in the IS direction was 0.53 mm for a sinusoidally moving target, with an average count rate ∼250 cps. The average prediction error was 1.1 ± 0.6 mm when the marker moved according to irregular patient breathing motion. Across all beam deliveries during the radiochromic film measurements, the average prediction error was 0.8 ± 0.5 mm. The maximum error was 2.5 mm and the 95th percentile error was 1.5 mm. Clear improvement of the dose distribution was observed between gated and nongated deliveries. The full-width at halfmaximum of the dose profiles of gated deliveries differed by 3 mm or less than the static reference dose distribution. Monitoring of the beam on/off times showed synchronization with the location of the marker within the latency of the system. CONCLUSIONS PeTrack can track the motion of internal fiducial positron emission markers with submillimeter precision. The system can be used to gate the delivery of a Linac beam based on the position of a moving fiducial marker. This highlights the potential of the system for use in respiratory-gated radiotherapy.
Collapse
Affiliation(s)
- Marc Chamberland
- Department of Physics, Carleton University, Ottawa, Ontario K1S 5B6, Canada
| | - Malcolm R McEwen
- Ionizing Radiation Standards, National Research Council of Canada, Ottawa, Ontario K1A 0R6, Canada
| | - Tong Xu
- Department of Physics, Carleton University, Ottawa, Ontario K1S 5B6, Canada
| |
Collapse
|
13
|
Tuncel N. Assessment of patient dose in medical processes by in-vivodose measuring devices: A review. EPJ WEB OF CONFERENCES 2016. [DOI: 10.1051/epjconf/201612804002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
14
|
Zhou J, Zamdborg L, Sebastian E. Review of advanced catheter technologies in radiation oncology brachytherapy procedures. Cancer Manag Res 2015; 7:199-211. [PMID: 26203277 PMCID: PMC4507789 DOI: 10.2147/cmar.s46042] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
The development of new catheter and applicator technologies in recent years has significantly improved treatment accuracy, efficiency, and outcomes in brachytherapy. In this paper, we review these advances, focusing on the performance of catheter imaging and reconstruction techniques in brachytherapy procedures using magnetic resonance images and electromagnetic tracking. The accuracy of catheter reconstruction, imaging artifacts, and other notable properties of plastic and titanium applicators in gynecologic treatments are reviewed. The accuracy, noise performance, and limitations of electromagnetic tracking for catheter reconstruction are discussed. Several newly developed applicators for accelerated partial breast irradiation and gynecologic treatments are also reviewed. New hypofractionated high dose rate treatment schemes in prostate cancer and accelerated partial breast irradiation are presented.
Collapse
Affiliation(s)
- Jun Zhou
- Department of Radiation Oncology, Beaumont Health System, Royal Oak, MI, USA
- Oakland University William Beaumont School of Medicine, Royal Oak, MI, USA
| | - Leonid Zamdborg
- Department of Radiation Oncology, Beaumont Health System, Royal Oak, MI, USA
| | - Evelyn Sebastian
- Department of Radiation Oncology, Beaumont Health System, Royal Oak, MI, USA
| |
Collapse
|
15
|
Poulin E, Racine E, Binnekamp D, Beaulieu L. Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system. Med Phys 2015; 42:1227-32. [DOI: 10.1118/1.4908011] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
16
|
Ploquin N, Kertzscher G, Vandervoort E, Cygler JE, Andersen CE, Francescon P. Use of novel fibre-coupled radioluminescence and RADPOS dosimetry systems for total scatter factor measurements in small fields. Phys Med Biol 2014; 60:1-14. [DOI: 10.1088/0031-9155/60/1/1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
17
|
Kertzscher G, Rosenfeld A, Beddar S, Tanderup K, Cygler JE. In vivo dosimetry: trends and prospects for brachytherapy. Br J Radiol 2014; 87:20140206. [PMID: 25007037 DOI: 10.1259/bjr.20140206] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The error types during brachytherapy (BT) treatments and their occurrence rates are not well known. The limited knowledge is partly attributed to the lack of independent verification systems of the treatment progression in the clinical workflow routine. Within the field of in vivo dosimetry (IVD), it is established that real-time IVD can provide efficient error detection and treatment verification. However, it is also recognized that widespread implementations are hampered by the lack of available high-accuracy IVD systems that are straightforward for the clinical staff to use. This article highlights the capabilities of the state-of-the-art IVD technology in the context of error detection and quality assurance (QA) and discusses related prospects of the latest developments within the field. The article emphasizes the main challenges responsible for the limited practice of IVD and provides descriptions on how they can be overcome. Finally, the article suggests a framework for collaborations between BT clinics that implemented IVD on a routine basis and postulates that such collaborations could improve BT QA measures and the knowledge about BT error types and their occurrence rates.
Collapse
Affiliation(s)
- G Kertzscher
- 1 Centre for Nuclear Technologies, Technical University of Denmark, Roskilde, Denmark
| | | | | | | | | |
Collapse
|
18
|
Kertzscher G, Andersen CE, Tanderup K. Adaptive error detection for HDR/PDR brachytherapy: Guidance for decision making during real-time in vivo
point dosimetry. Med Phys 2014; 41:052102. [DOI: 10.1118/1.4870438] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
|
19
|
Cherpak AJ, Cygler JE, E C, Perry G. Real-time measurement of urethral dose and position during permanent seed implantation for prostate brachytherapy. Brachytherapy 2014; 13:169-77. [DOI: 10.1016/j.brachy.2013.11.004] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2013] [Revised: 10/15/2013] [Accepted: 11/20/2013] [Indexed: 10/25/2022]
|
20
|
Therriault-Proulx F, Beddar S, Beaulieu L. On the use of a single-fiber multipoint plastic scintillation detector for 192Ir high-dose-rate brachytherapy. Med Phys 2014; 40:062101. [PMID: 23718599 DOI: 10.1118/1.4803510] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The goal of this study was to prove the feasibility of using a single-fiber multipoint plastic scintillation detector (mPSD) as an in vivo verification tool during (192)Ir high-dose-rate brachytherapy treatments. METHODS A three-point detector was built and inserted inside a catheter-positioning template placed in a water phantom. A hyperspectral approach was implemented to discriminate the different optical signals composing the light output at the exit of the single collection optical fiber. The mPSD was tested with different source-to-detector positions, ranging from 1 to 5 cm radially and over 10.5 cm along the longitudinal axis of the detector, and with various integration times. Several strategies for improving the accuracy of the detector were investigated. The device's accuracy in detecting source position was also tested. RESULTS Good agreement with the expected doses was obtained for all of the scintillating elements, with average relative differences from the expected values of 3.4 ± 2.1%, 3.0 ± 0.7%, and 4.5 ± 1.0% for scintillating elements from the distal to the proximal. A dose threshold of 3 cGy improved the general accuracy of the detector. An integration time of 3 s offered a good trade-off between precision and temporal resolution. Finally, the mPSD measured the radioactive source positioning uncertainty to be no more than 0.32 ± 0.06 mm. The accuracy and precision of the detector were improved by a dose-weighted function combining the three measurement points and known details about the geometry of the detector construction. CONCLUSIONS The use of a mPSD for high-dose-rate brachytherapy dosimetry is feasible. This detector shows great promise for development of in vivo applications for real-time verification of treatment delivery.
Collapse
Affiliation(s)
- François Therriault-Proulx
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030, USA
| | | | | |
Collapse
|
21
|
Prabhakar R. Real-time dosimetry in external beam radiation therapy. World J Radiol 2013; 5:352-355. [PMID: 24179630 PMCID: PMC3812446 DOI: 10.4329/wjr.v5.i10.352] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2013] [Revised: 08/02/2013] [Accepted: 10/12/2013] [Indexed: 02/06/2023] Open
Abstract
With growing complexity in radiotherapy treatment delivery, it has become mandatory to check each and every treatment plan before implementing clinically. This process is currently administered by an independent secondary check of all treatment parameters and as a pre-treatment quality assurance (QA) check for intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy treatment plans. Although pre-treatment IMRT QA is aimed to ensure the correct dose is delivered to the patient, it does not necessarily predict the clinically relevant patient dose errors. During radiotherapy, treatment uncertainties can affect tumor control and may increase complications to surrounding normal tissues. To combat this, image guided radiotherapy is employed to help ensure the plan conditions are mimicked on the treatment machine. However, it does not provide information on actual delivered dose to the tumor volume. Knowledge of actual dose delivered during treatment aid in confirming the prescribed dose and also to replan/reassess the treatment in situations where the planned dose is not delivered as expected by the treating physician. Major accidents in radiotherapy would have been averted if real time dosimetry is incorporated as part of the routine radiotherapy procedure. Of late real-time dosimetry is becoming popular with complex treatments in radiotherapy. Real-time dosimetry can be either in the form of point doses or planar doses or projected on to a 3D image dataset to obtain volumetric dose. They either provide entrance dose or exit dose or dose inside the natural cavities of a patient. In external beam radiotherapy, there are four different established platforms whereby the delivered dose information can be obtained: (1) Collimator; (2) Patient; (3) Couch; and (4) Electronic Portal Imaging Device. Current real-time dosimetric techniques available in radiotherapy have their own advantages and disadvantages and a combination of one or more of these methods provide vital information about the actual dose delivered to radiotherapy patients.
Collapse
|
22
|
Zhou J, Sebastian E, Mangona V, Yan D. Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: a preliminary performance study. Med Phys 2013; 40:021716. [PMID: 23387739 DOI: 10.1118/1.4788641] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE In order to increase the accuracy and speed of catheter reconstruction in a high-dose-rate (HDR) prostate implant procedure, an automatic tracking system has been developed using an electromagnetic (EM) device (trakSTAR, Ascension Technology, VT). The performance of the system, including the accuracy and noise level with various tracking parameters and conditions, were investigated. METHODS A direct current (dc) EM transmitter (midrange model) and a sensor with diameter of 1.3 mm (Model 130) were used in the trakSTAR system for tracking catheter position during HDR prostate brachytherapy. Localization accuracy was assessed under both static and dynamic analyses conditions. For the static analysis, a calibration phantom was used to investigate error dependency on operating room (OR) table height (bottom vs midposition vs top), sensor position (distal tip of catheter vs connector end of catheter), direction [left-right (LR) vs anterior-posterior (AP) vs superior-inferior (SI)], sampling frequency (40 vs 80 vs 120 Hz), and interference from OR equipment (present vs absent). The mean and standard deviation of the localization offset in each direction and the corresponding error vectors were calculated. For dynamic analysis, the paths of five straight catheters were tracked to study the effects of directions, sampling frequency, and interference of EM field. Statistical analysis was conducted to compare the results in different configurations. RESULTS When interference was present in the static analysis, the error vectors were significantly higher at the top table position (3.3 ± 1.3 vs 1.8 ± 0.9 mm at bottom and 1.7 ± 1.0 mm at middle, p < 0.001), at catheter end position (3.1 ± 1.1 vs 1.4 ± 0.7 mm at the tip position, p < 0.001), and at 40 Hz sampling frequency (2.6 ± 1.1 vs 2.4 ± 1.5 mm at 80 Hz and 1.8 ± 1.1 at 160 Hz, p < 0.001). So did the mean offset errors in the LR direction (-1.7 ± 1.4 vs 0.4 ± 0.5 mm in AP and 0.8 ± 0.8 mm in SI directions, p < 0.001). The error vectors were significantly higher with surrounding interference (2.2 ± 1.3 mm) vs without interference (1.0 ± 0.7 mm, p < 0.001). An accuracy of 1.6 ± 0.2 mm can be reached when using optimum configuration (160 Hz at middle table position). When interference was present in the dynamic tracking, the mean tracking errors in LR direction (1.4 ± 0.5 mm) was significantly higher than that in AP direction (0.3 ± 0.2 mm, p < 0.001). So did the mean vector errors at 40 Hz (2.1 ± 0.2 mm vs 1.3 ± 0.2 mm at 80 Hz and 0.9 ± 0.2 mm at 160 Hz, p < 0.05). However, when interference was absent, they were comparable in the both directions and at all sampling frequencies. An accuracy of 0.9 ± 0.2 mm was obtained for the dynamic tracking when using optimum configuration. CONCLUSIONS The performance of an EM tracking system depends highly on the system configuration and surrounding environment. The accuracy of EM tracking for catheter reconstruction in a prostate HDR brachytherapy procedure can be improved by reducing interference from surrounding equipment, decreasing distance from transmitter to tracking area, and choosing appropriated sampling frequency. A calibration scheme is needed to further reduce the tracking error when the interference is high.
Collapse
Affiliation(s)
- Jun Zhou
- Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI 48073, USA.
| | | | | | | |
Collapse
|
23
|
Tanderup K, Beddar S, Andersen CE, Kertzscher G, Cygler JE. In vivo
dosimetry in brachytherapy. Med Phys 2013; 40:070902. [DOI: 10.1118/1.4810943] [Citation(s) in RCA: 125] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
24
|
Reniers B, Landry G, Eichner R, Hallil A, Verhaegen F. In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: feasibility study. Med Phys 2012; 39:1925-35. [PMID: 22482614 DOI: 10.1118/1.3693049] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE In gynecological radiotherapy with high dose rate (HDR)(192)Ir brachytherapy, the treatment complexity has increased due to improved optimization techniques and dose constraints. As a consequence, it has become more important to verify the dose delivery to the target and also to the organs at risk (e.g., the bladder). In vivo dosimetry, where dosimeters are placed in or on the patient, is one way of verifying the dose but until recently this was hampered by motion of the radiation detectors with respect to the source. The authors present a novel dosimetry method using a position sensitive radiation detector. METHODS The prototype RADPOS system (Best Medical Canada) consists of a metal oxide field effect transistor (MOSFET) dosimeter coupled to a position-sensor, which deduces its 3D position in a magnetic field. To assess the feasibility of in vivo dosimetry based on the RADPOS system, different characteristics of the detector need to be investigated. Using a PMMA phantom, the positioning accuracy of the RADPOS system was quantified by comparing position readouts with the known position of the detector along the x and y-axes. RADPOS dose measurements were performed at various distances from a Nucletron(192)Ir source in a PMMA phantom to evaluate the energy dependence of the MOSFET. A sensitivity analysis was performed by calculating the dose after varying (1) the position of the RADPOS detector to simulate organ motion and (2) the position of the first dwell position to simulate errors in delivery. The authors also performed an uncertainty analysis to determine the action level (AL) that should be used during in vivo dosimetry. RESULTS Positioning accuracy is found to be within 1 mm in the 1-10 cm range from the origin along the x-axis (away from the transmitter), meeting the requirements for in vivo dosimetry. Similar results are obtained for the other axes. The ALs are chosen to take into account the total uncertainty on the measurements. As a consequence for in vivo dosimetry, it is determined that the RADPOS sensor, if placed, for example, in the bladder Foley balloon, would detect a 2 mm motion of the bladder, at a 5% chance of a false positive, with an AL limit of 9% of the dose delivered. The authors found that source position errors, caused by, e.g., a wrong first dwell position, are more difficult to detect; indeed, with our single RADPOS detector, positioned in the bladder, dwell position errors below 5 mm and resulting in a dose error within 10%, could be detected in the tandem but not in the colpostats. A possible solution to improve error detection is to use multiple MOSFETs to obtain multiple dose values. CONCLUSIONS In this study, the authors proposed a dosimetry procedure, based on the novel RADPOS system, to accurately determine the position of the radiation dosimeter with respect to the applicator. The authors found that it is possible to monitor the delivered dose in a point and compare it to the predetermined dose. This allows in principle the detection of problems such as bladder motion/filling or source mispositioning. Further clinical investigation is warranted.
Collapse
Affiliation(s)
- B Reniers
- Department of Radiation Oncology, Maastricht University Medical Center, Maastricht, The Netherlands.
| | | | | | | | | |
Collapse
|
25
|
Clinical use of a novel in vivo 4D monitoring system for simultaneous patient motion and dose measurements. Radiother Oncol 2012; 102:290-6. [DOI: 10.1016/j.radonc.2011.08.021] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2011] [Revised: 08/24/2011] [Accepted: 08/25/2011] [Indexed: 11/20/2022]
|
26
|
Mrčela I, Bokulić T, Izewska J, Budanec M, Fröbe A, Kusić Z. Optically stimulated luminescencein vivodosimetry for radiotherapy: physical characterization and clinical measurements in60Co beams. Phys Med Biol 2011; 56:6065-82. [DOI: 10.1088/0031-9155/56/18/018] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
27
|
Chamberland M, Wassenaar R, Spencer B, Xu T. Performance evaluation of real-time motion tracking using positron emission fiducial markers. Med Phys 2011; 38:810-9. [DOI: 10.1118/1.3537206] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
|
28
|
Cherpak A, Serban M, Seuntjens J, Cygler JE. 4D dose-position verification in radiation therapy using the RADPOS system in a deformable lung phantom. Med Phys 2010; 38:179-87. [DOI: 10.1118/1.3515461] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
|
29
|
Yin FF, Oldham M, Cai J, Wu Q. Dosimetry challenges for implementing emerging technologies. ACTA ACUST UNITED AC 2010; 250:8-11. [PMID: 21617745 DOI: 10.1088/1742-6596/250/1/012002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
During the last 10 years, radiation therapy technologies have gone through major changes, mainly related introduction of sophisticated delivery and imaging techniques to improve the target localization accuracy and dose conformity. While implementation of these emerging technologies such as image-guided SRS/SBRT, IMRT/IMAT, IGRT, 4D motion management, and special delivery technologies showed substantial clinical gains for patient care, many other factors, such as training/quality, efficiency/efficacy, and cost/effectiveness etc. remain to be challenging. This talk will address technical challenges for dosimetry verification of implementing these emerging technologies in radiation therapy.
Collapse
Affiliation(s)
- Fang-Fang Yin
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27516, USA
| | | | | | | |
Collapse
|
30
|
Archambault L, Briere TM, Pönisch F, Beaulieu L, Kuban DA, Lee A, Beddar S. Toward a real-time in vivo dosimetry system using plastic scintillation detectors. Int J Radiat Oncol Biol Phys 2010; 78:280-7. [PMID: 20231074 PMCID: PMC2889037 DOI: 10.1016/j.ijrobp.2009.11.025] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2009] [Revised: 10/23/2009] [Accepted: 11/05/2009] [Indexed: 10/19/2022]
Abstract
PURPOSE In the present study, we have presented and validated a plastic scintillation detector (PSD) system designed for real-time multiprobe in vivo measurements. METHODS AND MATERIALS The PSDs were built with a dose-sensitive volume of 0.4 mm(3). The PSDs were assembled into modular detector patches, each containing five closely packed PSDs. Continuous dose readings were performed every 150 ms, with a gap between consecutive readings of <0.3 ms. We first studied the effect of electron multiplication. We then assessed system performance in acrylic and anthropomorphic pelvic phantoms. RESULTS The PSDs were compatible with clinical rectal balloons and were easily inserted into the anthropomorphic phantom. With an electron multiplication average gain factor of 40, a twofold increase in the signal/noise ratio was observed, making near real-time dosimetry feasible. Under calibration conditions, the PSDs agreed with the ion chamber measurements to 0.08%. Precision, evaluated as a function of the total dose delivered, ranged from 2.3% at 2 cGy to 0.4% at 200 cGy. CONCLUSION Real-time PSD measurements are highly accurate and precise. These PSDs can be mounted onto rectal balloons, transforming these clinical devices into in vivo dose detectors without modifying current clinical practice. Real-time monitoring of the dose delivered near the rectum during prostate radiotherapy should help radiation oncologists protect this sensitive normal structure.
Collapse
Affiliation(s)
- Louis Archambault
- Department of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX, USA
| | - Tina M. Briere
- Department of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX, USA
| | - Falk Pönisch
- Department of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX, USA
| | - Luc Beaulieu
- Department of Radiation Oncology, The University of Texas M.D. Anderson Cancer Center, Houston, TX, USA
| | - Deborah A. Kuban
- Département de Radio-oncologie, Centre Hospitalier Universitaire de Québec, Québec, Québec, Canada
| | - Andrew Lee
- Département de Radio-oncologie, Centre Hospitalier Universitaire de Québec, Québec, Québec, Canada
| | - Sam Beddar
- Department of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX, USA
| |
Collapse
|