• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4695758)   Today's Articles (189)
For: Sampson A, Le Y, Williamson JF. Fast patient-specific Monte Carlo brachytherapy dose calculations via the correlated sampling variance reduction technique. Med Phys 2012;39:1058-68. [PMID: 22320816 DOI: 10.1118/1.3679018] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
Number Cited by Other Article(s)
1
Qin P, Lin G, Li X, Piao Z, Huang S, Wu W, Qi M, Ma J, Zhou L, Xu Y. A correlated sampling-based Monte Carlo simulation for fast CBCT iterative scatter correction. Med Phys 2023;50:1466-1480. [PMID: 36323626 DOI: 10.1002/mp.16073] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 10/03/2022] [Accepted: 10/24/2022] [Indexed: 11/06/2022]  Open
2
Robert C, Dumas I, Martinetti F, Chargari C, Haie-Meder C, Lefkopoulos D. Nouveaux algorithmes de calcul en curiethérapie pour les traitements par iridium 192. Cancer Radiother 2018;22:319-325. [DOI: 10.1016/j.canrad.2017.11.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Accepted: 11/15/2017] [Indexed: 10/16/2022]
3
Malin MJ, Palmer BR, DeWerd LA. Absolute measurement of LDR brachytherapy source emitted power: Instrument design and initial measurements. Med Phys 2016;43:796-806. [PMID: 26843242 DOI: 10.1118/1.4939666] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
4
Bonenfant É, Magnoux V, Hissoiny S, Ozell B, Beaulieu L, Després P. Fast GPU-based Monte Carlo simulations for LDR prostate brachytherapy. Phys Med Biol 2015;60:4973-86. [DOI: 10.1088/0031-9155/60/13/4973] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
5
Ababneh E, Dababneh S, Qatarneh S, Wadi-Ramahi S. Enhancement and validation of Geant4 Brachytherapy application on clinical HDR 192Ir source. Radiat Phys Chem Oxf Engl 1993 2014. [DOI: 10.1016/j.radphyschem.2014.05.040] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
6
Collins Fekete CA, Plamondon M, Martin AG, Vigneault É, Verhaegen F, Beaulieu L. Quantifying the effect of seed orientation in postplanning dosimetry of low-dose-rate prostate brachytherapy. Med Phys 2014;41:101704. [DOI: 10.1118/1.4895012] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]  Open
7
Shiinoki T, Sawada A, Ishihara Y, Miyabe Y, Matsuo Y, Mizowaki T, Kokubo M, Hiraoka M. Dosimetric impact of gold markers implanted closely to lung tumors: a Monte Carlo simulation. J Appl Clin Med Phys 2014;15:4594. [PMID: 24892332 PMCID: PMC5711066 DOI: 10.1120/jacmp.v15i3.4594] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2013] [Revised: 02/17/2014] [Accepted: 01/20/2014] [Indexed: 11/23/2022]  Open
8
Beaulieu L, Carlsson Tedgren A, Carrier JF, Davis SD, Mourtada F, Rivard MJ, Thomson RM, Verhaegen F, Wareing TA, Williamson JF. Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: Current status and recommendations for clinical implementation. Med Phys 2012;39:6208-36. [PMID: 23039658 DOI: 10.1118/1.4747264] [Citation(s) in RCA: 364] [Impact Index Per Article: 28.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA