Ding Z, Zeng Q, Kang K, Xu M, Xiang X, Liu C. Evaluation of Plan Robustness Using Hybrid Intensity-Modulated Radiotherapy (IMRT) and Volumetric Arc Modulation Radiotherapy (VMAT) for Left-Sided Breast Cancer.
Bioengineering (Basel) 2022;
9:bioengineering9040131. [PMID:
35447691 PMCID:
PMC9028731 DOI:
10.3390/bioengineering9040131]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 01/18/2022] [Accepted: 03/17/2022] [Indexed: 12/02/2022] Open
Abstract
Purpose: We aim to evaluate the robustness of multi-field IMRT and VMAT plans to target motion for left-sided BC radiotherapy. Methods: The 7-field hybrid IMRT (7F-H-IMRT) and 2-arc VMAT (2A-VMAT) plans were generated for ten left-sided BC patients. Shifts of 3 mm, 5 mm, and 10 mm in six directions were introduced and the perturbed dose distributions were recalculated. The dose differences (∆D) of the original plan and perturbed plan corresponded to the plan robustness for the structure. Results: Higher ∆D98%, ∆D95%, and ∆Dmean of CTV were observed in 2A-VMAT plans, which induced higher tumor control probability reductions. A higher ∆Dmean of CTV Boost was found in 7F-H-IMRT plans despite lower ∆D98% and ∆D95%. Shifts in the S-I direction exerted the largest effect on CTV and CTV Boost. Regarding OARs, shifts in R, P, and I directions contributed to increasing the received dose. The 2A-VMAT plans performed better dose sparing, but had a higher robustness in a high-dose volume of the left lung and heart. The 2A-VMAT plans decreased the max dose of LAD but exhibited lower robustness. Conclusion: The 2A-VMAT plans showed higher sensitivity to position deviation. Shifts in the S-I direction exerted the largest effect for CTV and CTV Boost.
Collapse