1
|
Hoegele W, Zhang V, Grace Vasquez E, Gineitaite I, Sajo E, Brivio D, Zygmanski P. Radioactive source localization employing resistive electrode array (REA) detector. Biomed Phys Eng Express 2024; 10:025027. [PMID: 38306969 DOI: 10.1088/2057-1976/ad25bd] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 02/02/2024] [Indexed: 02/04/2024]
Abstract
Objective.In this feasibility study, we explore an application of a Resistive Electrode Array (REA) for localization of a radioactive point source. The inverse problem posed by multichannel REA detection is studied from mathematical perspective and involves the questions of the minimal configuration of the conductive leads that can achieve this goal. The basic configuration consists of a circularly shaped REA with four opposite electrical lead-pairs at its perimeter.Approach.A robust mathematical reconstruction method for a 3D radioactive source relative to the REA is presented. The characteristic empirical Green's function for the detector response of the REA is determined by numerically solving Laplace equations with appropriate boundary conditions. Based on this model, Monte Carlo simulations of the inverse problem with Gaussian noise are performed and the overall accuracy of the localization is investigated.Main results.The results show a 3D error distribution of localization which is uniform in the (x,y)-plane of the REA and strongly correlated in the orthogonalz-axis. The overall accuracy decreases with higher distance of the source to the detector which is intuitive due to approximate flux dependence following the inverse square law. Further, a saturation in accuracy regarding the number of electrical leads and a linear dependence of the reconstruction error on the measurement noise level are observed.Significance.A broad range of REA detector configurations and their characteristics are investigated by this study for radioactive source localization allowing diverse practical applications with detector diameters ranging from millimeters to meters.
Collapse
Affiliation(s)
- Wolfgang Hoegele
- Munich University of Applied Sciences HM, Department of Computer Science and Mathematics, Germany
| | - Victoria Zhang
- Department of Physics, Harvard University, Cambridge, MA, 02138, United States of America
| | - Elena Grace Vasquez
- Department of Physics, University of California, Berkeley, CA, 94720-7300, United States of America
| | - Indre Gineitaite
- Department of Radiation Oncology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, 02115, United States of America
| | - Erno Sajo
- Department of Physics and Applied Physics, Medical Physics Program, University of Massachusetts Lowell, Lowell, MA, 01854, United States of America
| | - Davide Brivio
- Department of Radiation Oncology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, 02115, United States of America
| | - Piotr Zygmanski
- Department of Radiation Oncology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, 02115, United States of America
| |
Collapse
|
2
|
Brennen T, Galli L, Cutajar DL, Alnaghy S, Bucci J, Bece A, Enari K, Favoino M, Carriero M, Tartaglia M, Archer J, Lerch M, Rosenfeld AB, Petasecca M. BrachyView: development of an algorithm for real-time automatic LDR brachytherapy seed detection. Phys Med Biol 2020; 65:215015. [PMID: 32756019 DOI: 10.1088/1361-6560/abac9e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BrachyView is a novel in-body imaging system developed to provide real-time intraoperative dosimetry for low dose rate prostate brachytherapy treatments. Seed positions can be reconstructed after in-vivo implantation using a high-resolution pinhole gamma camera inserted into the patient rectum. The obtained data is a set of 2D projections of the seeds on the image plane. The 3D reconstruction algorithm requires the identification of the seed's centre of mass. This work presents the development and techniques adopted to build an algorithm that provides the means for fully automatic seed centre of mass identification and 3D position reconstruction for real-time applications. The algorithm presented uses a local feature detector, speeded up robust features, to perform detection of brachytherapy seed 2D projections from images, allowing for robust seed identification. Initial results have been obtained with datasets of 30, 96 and 98 I-125 brachytherapy seeds implanted into a prostate gel phantom. It can detect 97% of seeds and correctly match 97% of seeds. The average overall computation time of 2.75 s per image and improved reconstruction accuracy of 22.87% for the 98 seed dataset was noted. Elimination processes for initial false positive detection removal have shown to be extremely effective, resulting in a 99.9% reduction of false positives, and when paired with automatic frame alignment and subtraction procedures allows for the effective removal of excess counts generated by previously implanted needles. The proposed algorithm will allow the BrachyView system to be used as a real-time intraoperative dosimetry tool for low dose rate prostate brachytherapy treatments.
Collapse
Affiliation(s)
- T Brennen
- Centre for Medical Radiation Physics, University of Wollongong, Australia. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
3
|
|
4
|
BrachyView: Reconstruction of seed positions and volume of an LDR prostate brachytherapy patient plan using a baseline subtraction algorithm. Phys Med 2019; 66:66-76. [PMID: 31563727 DOI: 10.1016/j.ejmp.2019.09.237] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Revised: 09/13/2019] [Accepted: 09/19/2019] [Indexed: 11/22/2022] Open
Abstract
PURPOSE BrachyView is a novel in-body imaging system developed with the objective to provide real-time intraoperative dosimetry for low dose rate (LDR) prostate brachytherapy treatments. The BrachyView coordinates combined with conventional transrectal ultrasound (TRUS) imaging, provides the possibility to localise the effective position of the implanted seeds inside the prostate volume, providing a unique tool for intra-operative verification of the quality of the implantation. This research presents the first complete LDR brachytherapy plan reconstructed by the BrachyView system and is used to evaluate the effectiveness of an imaging algorithm with baseline subtraction. METHODS A plan featuring 98 I-125 brachytherapy seeds, with an average activity of 0.248 mCi, were implanted into a prostate gel phantom under TRUS guidance. Images of implanted seeds were obtained by the BrachyView after the implantation of seeds. The baseline subtraction algorithm is applied as a pixel-to-pixel counts subtraction and is applied to every second projection obtained after the implantation of each needle. Seed positions and effectiveness of the baseline reconstruction in the identification of seeds were verified by a high-resolution post-implant CT scan. RESULTS A complete brachytherapy plan has been reconstructed with a 100% detection rate. This is possible due to the effectiveness of the baseline subtraction, with its application an overall increase of 11.3% in position accuracy and 8.2% increase in detection rate was noted. CONCLUSION It has been demonstrated that the BrachyView system shows the potential to be a solution to providing clinics with the means for intraoperative dosimetry for LDR prostate brachytherapy treatments.
Collapse
|
5
|
Alabd R, Safavi-Naeini M, Wilson KJ, Rosenfeld AB, Franklin DR. A simulation study of BrachyShade, a shadow-based internal source tracking system for HDR prostate brachytherapy. Phys Med Biol 2018; 63:205019. [PMID: 30239336 DOI: 10.1088/1361-6560/aae33d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This paper presents a simulation study of BrachyShade, a proposed internal source-tracking system for real time quality assurance in high dose rate prostate brachytherapy. BrachyShade consists of a set of spherical tungsten occluders located above a pixellated silicon photodetector. The source location is estimated by minimising the mean squared error between a parametric model of the shadow image and acquired images of the shadows projected on the detector plane. A novel algorithm is finally employed to correct the systemic error resulting from Compton scattering in the medium. The worst-case error obtained with BrachyShade for a 13.5 ms image acquisition is less than 1.3 mm in the most distant part of the treatment volume, while for 75% of source locations an error of less than 0.42 mm was achieved.
Collapse
Affiliation(s)
- Roumani Alabd
- School of Electrical and Data Engineering, University of Technology Sydney, Ultimo NSW 2007, Australia
| | | | | | | | | |
Collapse
|
6
|
Semiconductor real-time quality assurance dosimetry in brachytherapy. Brachytherapy 2017; 17:133-145. [PMID: 28964727 DOI: 10.1016/j.brachy.2017.08.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2017] [Revised: 08/22/2017] [Accepted: 08/28/2017] [Indexed: 11/23/2022]
Abstract
With the increase in complexity of brachytherapy treatments, there has been a demand for the development of sophisticated devices for delivery verification. The Centre for Medical Radiation Physics (CMRP), University of Wollongong, has demonstrated the applicability of semiconductor devices to provide cost-effective real-time quality assurance for a wide range of brachytherapy treatment modalities. Semiconductor devices have shown great promise to the future of pretreatment and in vivo quality assurance in a wide range of brachytherapy treatments, from high-dose-rate (HDR) prostate procedures to eye plaque treatments. The aim of this article is to give an insight into several semiconductor-based dosimetry instruments developed by the CMRP. Applications of these instruments are provided for breast and rectal wall in vivo dosimetry in HDR brachytherapy, urethral in vivo dosimetry in prostate low-dose-rate (LDR) brachytherapy, quality assurance of HDR brachytherapy afterloaders, HDR pretreatment plan verification, and real-time verification of LDR and HDR source dwell positions.
Collapse
|
7
|
Shi C, Wang B. Preliminary Monte Carlo Investigation of Using Ir-192 as the Source for Real Time Imaging Purpose. INTERNATIONAL JOURNAL OF MEDICAL PHYSICS, CLINICAL ENGINEERING AND RADIATION ONCOLOGY 2017; 6:21-30. [PMID: 28824832 PMCID: PMC5562365 DOI: 10.4236/ijmpcero.2017.61003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The purpose of this study is to investigate the potential use of Ir-192 as the source for real time imaging during HDR (High Dose Rate) brachytherapy treatment. Phantom measurement was performed to determine outside of the body dose. Monte Carlo code, EGSnrcMP egs_inprz, was used for the simulation to calculate the outside of the body x-ray signal for CT reconstruction. Matlab code was developed to reconstruct the Ir-192 source and for 3D visualization in order to assess reconstructed CT resolution, signal-to-noise ratio, and imaging dose information. The measured dose was 0.67 ± 0.04 cGy, which was comparable to the Monte Carlo simulation result 0.71 ± 0.20 cGy. The reconstructed source diameter dimension was 1.3 mm compared with 1.1 mm for the real source dimension. The signal-to-noise ratio was 19.91 db following de-noising. Source position was within a 1 mm difference between programmed and simulated results. Although the Ir-192 signal is weak for CT imaging, it is possible to use it as a CT imaging x-ray source for HDR treatment localization, verification and dosimetry purposes. Further study is needed for the detailed design of an outside of the body CT-like device for use in brachytherapy imaging.
Collapse
Affiliation(s)
- Chengyu Shi
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Brian Wang
- Department of Radiation Oncology, James Brown Cancer Center, The University of Louisville, Louisville, KY, USA
| |
Collapse
|
8
|
Alnaghy S, Cutajar D, Bucci J, Enari K, Safavi-Naeini M, Favoino M, Tartaglia M, Carriero F, Jakubek J, Pospisil S, Lerch M, Rosenfeld A, Petasecca M. BrachyView: Combining LDR seed positions with transrectal ultrasound imaging in a prostate gel phantom. Phys Med 2017; 34:55-64. [DOI: 10.1016/j.ejmp.2017.01.012] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Revised: 01/12/2017] [Accepted: 01/14/2017] [Indexed: 01/22/2023] Open
|
9
|
Haworth A, Mears C, Betts JM, Reynolds HM, Tack G, Leo K, Williams S, Ebert MA. A radiobiology-based inverse treatment planning method for optimisation of permanent l-125 prostate implants in focal brachytherapy. Phys Med Biol 2015; 61:430-44. [PMID: 26675313 DOI: 10.1088/0031-9155/61/1/430] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Treatment plans for ten patients, initially treated with a conventional approach to low dose-rate brachytherapy (LDR, 145 Gy to entire prostate), were compared with plans for the same patients created with an inverse-optimisation planning process utilising a biologically-based objective. The 'biological optimisation' considered a non-uniform distribution of tumour cell density through the prostate based on known and expected locations of the tumour. Using dose planning-objectives derived from our previous biological-model validation study, the volume of the urethra receiving 125% of the conventional prescription (145 Gy) was reduced from a median value of 64% to less than 8% whilst maintaining high values of TCP. On average, the number of planned seeds was reduced from 85 to less than 75. The robustness of plans to random seed displacements needs to be carefully considered when using contemporary seed placement techniques. We conclude that an inverse planning approach to LDR treatments, based on a biological objective, has the potential to maintain high rates of tumour control whilst minimising dose to healthy tissue. In future, the radiobiological model will be informed using multi-parametric MRI to provide a personalised medicine approach.
Collapse
Affiliation(s)
- Annette Haworth
- Department Physical Sciences Peter MacCallum Cancer Centre, Vic, 3002, Australia. Sir Peter MacCallum Department of Oncology, University of Melbourne, Vic, 3010, Australia
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Safavi-Naeini M, Han Z, Alnaghy S, Cutajar D, Petasecca M, Lerch MLF, Franklin DR, Bucci J, Carrara M, Zaider M, Rosenfeld AB. BrachyView, a novel in-body imaging system for HDR prostate brachytherapy: Experimental evaluation. Med Phys 2015; 42:7098-107. [DOI: 10.1118/1.4935866] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
11
|
Loo K, Jakubek J, Zemlicka J, Petasecca M, Safavi-Naeini M, Bucci J, Zaider M, Rosenfeld A. BrachyView: Feasibility study into the application of Timepix detectors for soft tissue thickness imaging in prostate brachytherapy treatment. RADIAT MEAS 2014. [DOI: 10.1016/j.radmeas.2014.03.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
12
|
Kertzscher G, Rosenfeld A, Beddar S, Tanderup K, Cygler JE. In vivo dosimetry: trends and prospects for brachytherapy. Br J Radiol 2014; 87:20140206. [PMID: 25007037 DOI: 10.1259/bjr.20140206] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The error types during brachytherapy (BT) treatments and their occurrence rates are not well known. The limited knowledge is partly attributed to the lack of independent verification systems of the treatment progression in the clinical workflow routine. Within the field of in vivo dosimetry (IVD), it is established that real-time IVD can provide efficient error detection and treatment verification. However, it is also recognized that widespread implementations are hampered by the lack of available high-accuracy IVD systems that are straightforward for the clinical staff to use. This article highlights the capabilities of the state-of-the-art IVD technology in the context of error detection and quality assurance (QA) and discusses related prospects of the latest developments within the field. The article emphasizes the main challenges responsible for the limited practice of IVD and provides descriptions on how they can be overcome. Finally, the article suggests a framework for collaborations between BT clinics that implemented IVD on a routine basis and postulates that such collaborations could improve BT QA measures and the knowledge about BT error types and their occurrence rates.
Collapse
Affiliation(s)
- G Kertzscher
- 1 Centre for Nuclear Technologies, Technical University of Denmark, Roskilde, Denmark
| | | | | | | | | |
Collapse
|