Páez-Carpio A, Gómez FM, Isus Olivé G, Paredes P, Baetens T, Carrero E, Sánchez M, Vollmer I. Image-guided percutaneous ablation for the treatment of lung malignancies: current state of the art. Insights Imaging 2021; 12:57. [PMID: 33914187 PMCID: PMC8085189 DOI: 10.1186/s13244-021-00997-5] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Accepted: 04/09/2021] [Indexed: 12/25/2022] Open
Abstract
Image-guided percutaneous lung ablation has proven to be a valid treatment alternative in patients with early-stage non-small cell lung carcinoma or oligometastatic lung disease. Available ablative modalities include radiofrequency ablation, microwave ablation, and cryoablation. Currently, there are no sufficiently representative studies to determine significant differences between the results of these techniques. However, a common feature among them is their excellent tolerance with very few complications. For optimal treatment, radiologists must carefully select the patients to be treated, perform a refined ablative technique, and have a detailed knowledge of the radiological features following lung ablation. Although no randomized studies comparing image-guided percutaneous lung ablation with surgery or stereotactic radiation therapy are available, the current literature demonstrates equivalent survival rates. This review will discuss image-guided percutaneous lung ablation features, including available modalities, approved indications, possible complications, published results, and future applications.
Collapse
Affiliation(s)
- Alfredo Páez-Carpio
- Department of Radiology, CDI, Hospital Clínic, University of Barcelona, Barcelona, Spain.
| | - Fernando M Gómez
- Department of Radiology, CDI, Hospital Clínic, University of Barcelona, Barcelona, Spain.,Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Gemma Isus Olivé
- Department of Radiology, CDI, Hospital Clínic, University of Barcelona, Barcelona, Spain
| | - Pilar Paredes
- Department of Nuclear Medicine, CDI, Hospital Clínic, University of Barcelona, Barcelona, Spain
| | - Tarik Baetens
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Enrique Carrero
- Department of Anesthesiology, Hospital Clínic, University of Barcelona, Barcelona, Spain
| | - Marcelo Sánchez
- Department of Radiology, CDI, Hospital Clínic, University of Barcelona, Barcelona, Spain
| | - Ivan Vollmer
- Department of Radiology, CDI, Hospital Clínic, University of Barcelona, Barcelona, Spain
| |
Collapse
|
2
|
Evaluation of surface dose and image quality using the half-scan mode in chest computed tomography-guided interventional radiology: a phantom study. Radiol Phys Technol 2018; 11:138-148. [DOI: 10.1007/s12194-018-0445-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2017] [Revised: 02/14/2018] [Accepted: 02/17/2018] [Indexed: 10/17/2022]
|
3
|
Teles P, Nikodemová D, Bakhanova E, Becker F, Kneževic Ž, Pereira MF, Sarmento S. A Review of Radiation Protection Requirements and Dose Estimation for Staff and Patients in CT Fluoroscopy. RADIATION PROTECTION DOSIMETRY 2017; 174:518-534. [PMID: 27522054 DOI: 10.1093/rpd/ncw231] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2016] [Accepted: 07/06/2016] [Indexed: 06/06/2023]
Abstract
The combination of fluoroscopically guided interventional procedures with computed tomography (CTF) has become widespread around the world. The benefits of CTF include the ability to obtain a real-time visualization of the entire body, increased target accuracy and improved visualization of biopsy needles. Modern CTF units work with variable frame rates for image selection, and therefore the dose distributions for patients and staff can considerably vary, creating growing concern in terms of the occupational exposure of interventionists and the drawback of a higher exposure of the patient. A literature review of the latest CTF publications is summarized in this article. A wide range of CTF studies reveal different treatment methods used in clinical practice, and therefore the differences in the exposures between them; as well as in the radiation protection tools and dose monitoring. Further optimization of radiation protection methods, harmonization of exposure patterns as well as training and education of CTF staff on the basis of the information in the survey, are strongly recommended.
Collapse
Affiliation(s)
- P Teles
- Grupo de Proteção e Segurança Radiológica, Centro de Ciências e Tecnologias Nucleares (C2TN), Instituto Superior Técnico, Universidade de Lisboa, Pólo de Loures. Estrada Nacional 10 (km 139,7), 2695-066 Bobadela LRS, Portugal
| | - D Nikodemová
- Slovak Medical University, Limbová 14, 83301 Bratislava, Slovakia
| | - E Bakhanova
- National Research Center for Radiation Medicine, NAMS Ukraine, Melnikova 53, Kiev 04050, Ukraine
| | - F Becker
- Institute for Nuclear Waste Disposal, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | - Ž Kneževic
- Ruder Boškovic Institute, Bijenicka 54, 10000 Zagreb, Croatia
| | - M F Pereira
- Grupo de Proteção e Segurança Radiológica, Centro de Ciências e Tecnologias Nucleares (C2TN), Instituto Superior Técnico, Universidade de Lisboa, Pólo de Loures. Estrada Nacional 10 (km 139,7), 2695-066 Bobadela LRS, Portugal
- Laboratório de Proteção e Segurança Radiológica (LPSR), Instituto Superior Técnico, Universidade de Lisboa, Pólo de Loures. Estrada Nacional 10 (km 139,7), 2695-066 Bobadela LRS, Portugal
| | - S Sarmento
- Medical Physics, Radiobiology and Radiation Protection Group, IPO Porto Research Center (CI-IPOP), Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
| |
Collapse
|
4
|
Hasegawa H, Sato M, Tanaka H. Evaluation of an X-Ray Dose Profile Derived from an Optically Stimulated Luminescent Dosimeter during Computed Tomographic Fluoroscopy. PLoS One 2015; 10:e0132154. [PMID: 26151914 PMCID: PMC4494858 DOI: 10.1371/journal.pone.0132154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2015] [Accepted: 06/10/2015] [Indexed: 11/19/2022] Open
Abstract
The purpose of this study was to evaluate scatter radiation dose to the subject surface during X-ray computed tomography (CT) fluoroscopy using the integrated dose ratio (IDR) of an X-ray dose profile derived from an optically stimulated luminescent (OSL) dosimeter. We aimed to obtain quantitative evidence supporting the radiation protection methods used during previous CT fluoroscopy. A multislice CT scanner was used to perform this study. OSL dosimeters were placed on the top and the lateral side of the chest phantom so that the longitudinal direction of dosimeters was parallel to the orthogonal axis-to-slice plane for measurement of dose profiles in CT fluoroscopy. Measurement of fluoroscopic conditions was performed at 120 kVp and 80 kVp. Scatter radiation dose was evaluated by calculating the integrated dose determined by OSL dosimetry. The overall percent difference of the integrated doses between OSL dosimeters and ionization chamber was 5.92%. The ratio of the integrated dose of a 100-mm length area to its tails (−50 to −6 mm, 50 to 6 mm) was the lowest on the lateral side at 80 kVp and the highest on the top at 120 kVp. The IDRs for different measurement positions were larger at 120 kVp than at 80 kVp. Similarly, the IDRs for the tube voltage between the primary X-ray beam and scatter radiation was larger on the lateral side than on the top of the phantom. IDR evaluation suggested that the scatter radiation dose has a high dependence on the position and a low dependence on tube voltage relative to the primary X-ray beam for constant dose rate fluoroscopic conditions. These results provided quantitative evidence supporting the radiation protection methods used during CT fluoroscopy in previous studies.
Collapse
Affiliation(s)
- Hiroaki Hasegawa
- Department of Bioinformatics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo, Japan
- * E-mail:
| | - Masanori Sato
- Department of Radiological Sciences, Graduate School of Health Sciences, Komazawa University, Setagaya-ku, Tokyo, Japan
| | - Hiroshi Tanaka
- Department of Bioinformatics, Division of Medical Genomics, Medical Research Institute, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo, Japan
| |
Collapse
|