Hetzel R, Urbanevych V, Bolke A, Kasper J, Kercz M, Kołodziej M, Magiera A, Mueller F, Müller S, Rafecas M, Rusiecka K, Schug D, Schulz V, Stahl A, Weissler B, Wong ML, Wrońska A. Near-field coded-mask technique and its potential for proton therapy monitoring. Phys Med Biol 2023; 68:245028. [PMID: 37863101 DOI: 10.1088/1361-6560/ad05b2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Accepted: 10/20/2023] [Indexed: 10/22/2023]
Abstract
Objective.Prompt-gamma imaging encompasses several approaches to the online monitoring of the beam range or deposited dose distribution in proton therapy. We test one of the imaging techniques - a coded mask approach - both experimentally and via simulations.Approach.Two imaging setups have been investigated experimentally. Each of them comprised a structured tungsten collimator in the form of a modified uniformly redundant array mask and a LYSO:Ce scintillation detector of fine granularity. The setups differed in detector dimensions and operation mode (1D or 2D imaging). A series of measurements with radioactive sources have been conducted, testing the performance of the setups for near-field gamma imaging. Additionally, Monte Carlo simulations of a larger setup of the same type were conducted, investigating its performance with a realistic gamma source distribution occurring during proton therapy.Main results.The images of point-like sources reconstructed from two small-scale prototypes' data using the maximum-likelihood expectation maximisation algorithm constitute the experimental proof of principle for the near-field coded-mask imaging modality, both in the 1D and the 2D mode. Their precision allowed us to calibrate out certain systematic offsets appearing due to the limited alignment accuracy of setup elements. The simulation of the full-scale setup yielded a mean distal falloff retrieval precision of 0.72 mm in the studies for beam energy range 89.5-107.9 MeV and with 1 × 108protons (a typical number for distal spots). The implemented algorithm of image reconstruction is relatively fast-a typical procedure needs several seconds.Significance.Coded-mask imaging appears a valid option for proton therapy monitoring. The results of simulations let us conclude that the proposed full-scale setup is competitive with the knife-edge-shaped and the multi-parallel slit cameras investigated by other groups.
Collapse
Affiliation(s)
- Ronja Hetzel
- III. Physikalisches Institut B, RWTH Aachen University, Aachen, Germany
| | - Vitalii Urbanevych
- Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków, Poland
| | - Andreas Bolke
- Institute of Medical Engineering, University of Lübeck, Lübeck, Germany
| | - Jonas Kasper
- III. Physikalisches Institut B, RWTH Aachen University, Aachen, Germany
| | - Monika Kercz
- Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków, Poland
- Doctoral School of Exact and Natural Sciences, Jagiellonian University, Kraków, Poland
| | - Magdalena Kołodziej
- Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków, Poland
- Doctoral School of Exact and Natural Sciences, Jagiellonian University, Kraków, Poland
| | - Andrzej Magiera
- Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków, Poland
| | - Florian Mueller
- Physics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany
| | - Sara Müller
- III. Physikalisches Institut B, RWTH Aachen University, Aachen, Germany
| | - Magdalena Rafecas
- Institute of Medical Engineering, University of Lübeck, Lübeck, Germany
| | - Katarzyna Rusiecka
- Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków, Poland
| | - David Schug
- Physics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany
- Hyperion Hybrid Imaging Systems GmbH, Aachen, Germany
| | - Volkmar Schulz
- III. Physikalisches Institut B, RWTH Aachen University, Aachen, Germany
- Physics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany
- Hyperion Hybrid Imaging Systems GmbH, Aachen, Germany
| | - Achim Stahl
- III. Physikalisches Institut B, RWTH Aachen University, Aachen, Germany
| | - Bjoern Weissler
- Physics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany
- Hyperion Hybrid Imaging Systems GmbH, Aachen, Germany
| | - Ming-Liang Wong
- Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków, Poland
| | - Aleksandra Wrońska
- Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków, Poland
| |
Collapse
|
2
|
Malekzadeh E, Rajabi H, Tajik-Mansoury MA, Sabouri P, Fiorina E, Kalantari F. Design and performance evaluation of a slit-slat camera for 2D prompt gamma imaging in proton therapy monitoring: A Monte Carlo simulation study. Med Phys 2023. [PMID: 36718592 DOI: 10.1002/mp.16259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 12/21/2022] [Accepted: 12/26/2022] [Indexed: 02/01/2023] Open
Abstract
PURPOSE We investigated the design of a prompt gamma camera for real-time dose delivery verification and the partial mitigation of range uncertainties. METHODS A slit slat (SS) camera was optimized using the trade-off between the signal-to-noise ratio and spatial resolution. Then, using the GATE Monte Carlo package, the camera performances were estimated by means of target shifts, beam position quantification, changing the camera distance from the beam, and air cavity inserting. A homogeneous PMMA phantom and the air gaps induced PMMA phantom were used. The air gaps ranged from 5 mm to 30 mm by 5 mm increments were positioned in the middle of the beam range. To reduce the simulation time, phase space scoring was used. The batch method with five realizations was used for stochastic error calculations. RESULTS The system's detection efficiency was 1.1 × 10 - 4 PGs Emitted PGs ( 1.8 × 10 - 5 $1.1 \times {10}^{-4}\frac{{\rm PGs}}{{\rm Emitted}\ {\rm PGs}}\ (1.8 \times {10}^{-5}$ PGs/proton) for a 10 × 20 cm2 detector (source-to-collimator distance = 15.0 cm). Axial and transaxial resolutions were 23 mm and 18 mm, respectively. The SS camera estimated the range as 69.0 ± 3.4 (relative stochastic error 1-sigma is 5%) and 67.6 ± 1.8 mm (2.6%) for the real range of 67.0 mm for 107 and 108 protons of 100 MeV, respectively. Considering 160 MeV, these values are 155.5 ± 3.1 (2%) and 152.2 ± 2.0 mm (1.3%) for the real range of 152.0 mm for 107 and 108 protons, respectively. Considering phantom shift, for a 100 MeV beam, the precision of the quantification (1-sigma) in the axial and lateral phantom shift estimation is 2.6 mm and 1 mm, respectively. Accordingly, the axial and lateral quantification precisions were 1.3 mm and 1 mm for a 160 MeV beam, respectively. Furthermore, the quantification of an air gap formulated as gap d e t = 0.98 × gap real ${{\rm gap}}_{det}=0.98 \times {{\rm gap}}_{{\rm real}}$ , where gap d e t ${{\rm gap}}_{det}$ and gapreal are the estimated and real air gap, respectively. The precision of the air gap quantification is 1.6 mm (1 sigma). Moreover, 2D PG images show the trajectory of the proton beam through the phantom. CONCLUSION The proposed slit-slat imaging systems can potentially provide a real-time, in-vivo, and non-invasive treatment monitoring method for proton therapy.
Collapse
Affiliation(s)
- Etesam Malekzadeh
- Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
| | - Hossein Rajabi
- Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
| | - Mohammad Ali Tajik-Mansoury
- Biomedical Engineering and Medical Physics Department, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Pouya Sabouri
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| | - Elisa Fiorina
- National Institute of Nuclear Physics INFN, Section of Torino, Torino, Italy.,Clinical Department, Fondazione CNAO, Pavia, Italy
| | - Faraz Kalantari
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| |
Collapse
|
3
|
Mohan R, Das IJ, Ling CC. Empowering Intensity Modulated Proton Therapy Through Physics and Technology: An Overview. Int J Radiat Oncol Biol Phys 2017; 99:304-316. [PMID: 28871980 PMCID: PMC5651132 DOI: 10.1016/j.ijrobp.2017.05.005] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2017] [Revised: 04/11/2017] [Accepted: 05/02/2017] [Indexed: 01/15/2023]
Abstract
Considering the clinical potential of protons attributable to their physical characteristics, interest in proton therapy has increased greatly in this century, as has the number of proton therapy installations. Until recently, passively scattered proton therapy was used almost entirely. Notably, the overall clinical results to date have not shown a convincing benefit of protons over photons. A rapid transition is now occurring with the implementation of the most advanced form of proton therapy, intensity modulated proton therapy (IMPT). IMPT is superior to passively scattered proton therapy and intensity modulated radiation therapy (IMRT) dosimetrically. However, numerous limitations exist in the present IMPT methods. In particular, compared with IMRT, IMPT is highly vulnerable to various uncertainties. In this overview we identify three major areas of current limitations of IMPT: treatment planning, treatment delivery, and motion management, and discuss current and future efforts for improvement. For treatment planning, we need to reduce uncertainties in proton range and in computed dose distributions, improve robust planning and optimization, enhance adaptive treatment planning and delivery, and consider how to exploit the variability in the relative biological effectiveness of protons for clinical benefit. The quality of proton therapy also depends on the characteristics of the IMPT delivery systems and image guidance. Efforts are needed to optimize the beamlet spot size for both improved dose conformality and faster delivery. For the latter, faster energy switching time and increased dose rate are also needed. Real-time in-room volumetric imaging for guiding IMPT is in its early stages with cone beam computed tomography (CT) and CT-on-rails, and continued improvements are anticipated. In addition, imaging of the proton beams themselves, using, for instance, prompt γ emissions, is being developed to determine the proton range and to reduce range uncertainty. With the realization of the advances described above, we posit that IMPT, thus empowered, will lead to substantially improved clinical results.
Collapse
Affiliation(s)
- Radhe Mohan
- Department of Radiation Physics, MD Anderson Cancer Center, Houston, Texas.
| | - Indra J Das
- Department of Radiation Oncology, New York University Langone Medical Center, New York, New York
| | - Clifton C Ling
- Varian Medical Systems and Department of Radiation Oncology, Stanford University, Stanford, California
| |
Collapse
|