• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4591707)   Today's Articles (1619)   Subscriber (49314)
For: Ramsay EB, Reinstein LE, Meek AG. Tests of an electron monitor for routine quality control measurements of electron energies. Med Phys 1991;18:1247-50. [PMID: 1753912 DOI: 10.1118/1.596598] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]  Open
Number Cited by Other Article(s)
1
Evaluation of the depth-ratio and backscattering-factor methods in quality control measurements of electron beam energies. Appl Radiat Isot 2005;63:217-22. [PMID: 15963431 DOI: 10.1016/j.apradiso.2005.01.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2003] [Revised: 01/07/2005] [Accepted: 01/30/2005] [Indexed: 11/18/2022]
2
A design study for a  spiral staircase  ionization chamber for the quality control of electron beams. Phys Med Biol 2004;49:N181-90. [PMID: 15285263 DOI: 10.1088/0031-9155/49/13/n01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
3
An automated procedure for the quality assurance of electron beam output and energy. Med Phys 2004;31:972-4. [PMID: 15191280 DOI: 10.1118/1.1688040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
4
Electron energy constancy verification using a double-wedge phantom. J Appl Clin Med Phys 2003;4:204-8. [PMID: 12841790 PMCID: PMC5724443 DOI: 10.1120/jacmp.v4i3.2516] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]  Open
5
Stability of electron-beam energy monitor for quality assurance of the electron-beam energy from radiotherapy accelerators. TOHOKU J EXP MED 2002;198:197-201. [PMID: 12597247 DOI: 10.1620/tjem.198.197] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
6
Detecting electron beam energy shifts with a commercially available energy monitor. Med Phys 2000;27:1661-3. [PMID: 10947270 DOI: 10.1118/1.599033] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
7
The electron linac accident of Zaragoza – could it have been avoided by an energy monitor? Z Med Phys 1992. [DOI: 10.1016/s0939-3889(15)70649-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA