Lee WJ, Kim DS, Kang SW, Yi WJ. Material depth reconstruction method of multi-energy X-ray images using neural network. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2012:1514-1517. [PMID: 23366190 DOI: 10.1109/embc.2012.6346229] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
With the advent of technology, multi-energy X-ray imaging is promising technique that can reduce the patient's dose and provide functional imaging. Two-dimensional photon-counting detector to provide multi-energy imaging is under development. In this work, we present a material decomposition method using multi-energy images. To acquire multi-energy images, Monte Carlo simulation was performed. The X-ray spectrum was modeled and ripple effect was considered. Using the dissimilar characteristics in energy-dependent X-ray attenuation of each material, multiple energy X-ray images were decomposed into material depth images. Feedforward neural network was used to fit multi-energy images to material depth images. In order to use the neural network, step wedge phantom images were used for training neuron. Finally, neural network decomposed multi-energy X-ray images into material depth image. To demonstrate the concept of this method, we applied it to simulated images of a 3D head phantom. The results show that neural network method performed effectively material depth reconstruction.
Collapse
Affiliation(s)
- Woo-Jin Lee
- College of Medicine, BK21, Seoul National University, South Korea
| | | | | | | |
Collapse
|
2
|
Bontempi M, Andreani L, Rossi PL, Visani A. Monte Carlo simulator of realistic x-ray beam for diagnostic applications. Med Phys 2010; 37:4201-9. [PMID: 20879581 DOI: 10.1118/1.3453578] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Abstract
PURPOSE Monte Carlo simulation is a very useful tool for radiotherapy and diagnostic radiology. Yet even with the latest PCs, simulation of photon spectra emitted by an x-ray tube is a time-consuming task, potentially reducing the possibility to obtain relevant data such as dose evaluations, simulation of geometric settings, or monitor detector efficiency. This study developed and validated a method to generate random numbers for realistic beams in terms of photon spectrum and intensity to simulate x-ray tubes via Monte Carlo algorithms. METHODS Starting from literature data, the most common semiempirical models of bremsstrahlung are analyzed and implemented, adjusting their formulation to describe a large irradiation area (i.e., large field of view) and to take account of the heel effect as in common practice during patient examinations. RESULTS Simulation results show that Birch and Marshall's model is the fastest and most accurate for the aims of this work. Correction of the geometric size of the beam and validation of the intensity variation (heel effect) yielded excellent results with differences between experimental and simulated data of less than 6%. CONCLUSIONS The results of validation and execution time showed that the tube simulator calculates the x-ray photons quickly and efficiently and is perfectly capable of considering all the phenomena occurring in a real beam (total filtration, focal spot size, and heel effect), so it can be used in a wide range of applications such as industry, medical physics, or quality assurance.
Collapse
Affiliation(s)
- Marco Bontempi
- Biomechanics Laboratory, Istituto Ortopedico Rizzoli, Bologna, Italy.
| | | | | | | |
Collapse
|
3
|
Mehranian A, Ay MR, Alam NR, Zaidi H. Quantifying the effect of anode surface roughness on diagnostic x-ray spectra using Monte Carlo simulation. Med Phys 2010; 37:742-52. [PMID: 20229884 DOI: 10.1118/1.3284212] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The accurate prediction of x-ray spectra under typical conditions encountered in clinical x-ray examination procedures and the assessment of factors influencing them has been a longstanding goal of the diagnostic radiology and medical physics communities. In this work, the influence of anode surface roughness on diagnostic x-ray spectra is evaluated using MCNP4C-based Monte Carlo simulations. METHODS An image-based modeling method was used to create realistic models from surface-cracked anodes. An in-house computer program was written to model the geometric pattern of cracks and irregularities from digital images of focal track surface in order to define the modeled anodes into MCNP input file. To consider average roughness and mean crack depth into the models, the surface of anodes was characterized by scanning electron microscopy and surface profilometry. It was found that the average roughness (Ra) in the most aged tube studied is about 50 pm. The correctness of MCNP4C in simulating diagnostic x-ray spectra was thoroughly verified by calling its Gaussian energy broadening card and comparing the simulated spectra with experimentally measured ones. The assessment of anode roughness involved the comparison of simulated spectra in deteriorated anodes with those simulated in perfectly plain anodes considered as reference. From these comparisons, the variations in output intensity, half value layer (HVL), heel effect, and patient dose were studied. RESULTS An intensity loss of 4.5% and 16.8% was predicted for anodes aged by 5 and 50 microm deep cracks (50 kVp, 6 degrees target angle, and 2.5 mm A1 total filtration). The variations in HVL were not significant as the spectra were not hardened by more than 2.5%; however, the trend for this variation was to increase with roughness. By deploying several point detector tallies along the anode-cathode direction and averaging exposure over them, it was found that for a 6 degrees anode, roughened by 50 microm deep cracks, the reduction in exposure is 14.9% and 13.1% for 70 and 120 kVp tube voltages, respectively. For the evaluation of patient dose, entrance skin radiation dose was calculated for typical chest x-ray examinations. It was shown that as anode roughness increases, patient entrance skin dose decreases averagely by a factor of 15%. CONCLUSIONS It was concluded that the anode surface roughness can have a non-negligible effect on output spectra in aged x-ray imaging tubes and its impact should be carefully considered in diagnostic x-ray imaging modalities.
Collapse
Affiliation(s)
- A Mehranian
- Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, P.O. Box 14155-6447, Tehran, Iran
| | | | | | | |
Collapse
|
4
|
Huda W, Nickoloff EL, Boone JM. Overview of patient dosimetry in diagnostic radiology in the USA for the past 50 years. Med Phys 2009; 35:5713-28. [PMID: 19175129 DOI: 10.1118/1.3013604] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
This review covers the role of medical physics in addressing issues directly related to patient dosimetry in radiography, fluoroscopy, mammography, and CT. The sections on radiography and fluoroscopy radiation doses review the changes that have occurred during the last 50 to 60 years. A number of technological improvements have contributed to both a significant reduction in patient and staff radiation doses and improvements to the image quality during this period of time. There has been a transition from film-screen radiography with hand dip film processing to electronic digital imaging utilizing CR and DR. Similarly, fluoroscopy has progressed by directly viewing image intensifiers in darkened rooms to modern flat panel image receptor systems utilizing pulsed radiation, automated variable filtration, and digitally processed images. Mammography is one of the most highly optimized imaging procedures performed, because it is a repetitive screening procedure that results in annual radiation exposure. Mammography is also the only imaging procedure in the United States in which the radiation dose is regulated by the federal government. Consequently, many medical physicists have studied the dosimetry associated with screen-film and digital mammography. In this review, a brief history of mammography dose assessment by medical physicists is discussed. CT was introduced into clinical practice in the early 1970s, and has grown into one of the most important modalities available for diagnostic imaging. CT dose quantities and measurement techniques are described, and values of radiation dose for different types of scanner are presented. Organ and effective doses to adult patients are surveyed from the earliest single slice scanners, to the latest versions that include up to two x-ray tubes and can incorporate as many as 256 detector channels. An overview is provided of doses received by pediatric patients undergoing CT examinations, as well as methods, and results, of studies performed to assess the radiation absorbed by the conceptus of pregnant patients.
Collapse
Affiliation(s)
- Walter Huda
- Department of Radiology, Medical University of South Carolina, Charleston, South Carolina 29425-3230, USA.
| | | | | |
Collapse
|
5
|
Costa PR, Nersissian DY, Salvador FC, Rio PB, Caldas LVE. Generation of calibrated tungsten target x-ray spectra: modified TBC model. HEALTH PHYSICS 2007; 92:24-32. [PMID: 17164596 DOI: 10.1097/01.hp.0000231565.66004.f9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
In spite of the recent advances in the experimental detection of x-ray spectra, theoretical or semi-empirical approaches for determining realistic x-ray spectra in the range of diagnostic energies are important tools for planning experiments, estimating radiation doses in patients, and formulating radiation shielding models. The TBC model is one of the most useful approaches since it allows for straightforward computer implementation, and it is able to accurately reproduce the spectra generated by tungsten target x-ray tubes. However, as originally presented, the TBC model fails in situations where the determination of x-ray spectra produced by an arbitrary waveform or the calculation of realistic values of air kerma for a specific x-ray system is desired. In the present work, the authors revisited the assumptions used in the original paper published by . They proposed a complementary formulation for taking into account the waveform and the representation of the calculated spectra in a dosimetric quantity. The performance of the proposed model was evaluated by comparing values of air kerma and first and second half value layers from calculated and measured spectra by using different voltages and filtrations. For the output, the difference between experimental and calculated data was better then 5.2%. First and second half value layers presented differences of 23.8% and 25.5% in the worst case. The performance of the model in accurately calculating these data was better for lower voltage values. Comparisons were also performed with spectral data measured using a CZT detector. Another test was performed by the evaluation of the model when considering a waveform distinct of a constant potential. In all cases the model results can be considered as a good representation of the measured data. The results from the modifications to the TBC model introduced in the present work reinforce the value of the TBC model for application of quantitative evaluations in radiation physics.
Collapse
Affiliation(s)
- Paulo R Costa
- Instituto de Eletrotécnica e Energia/Universidade de São Paulo, Brazil.
| | | | | | | | | |
Collapse
|
6
|
Terini RA, Pereira MAG, Künzel R, Costa PR, Herdade SB. Comprehensive analysis of the spectrometric determination of voltage applied to X-ray tubes in the radiography and mammography energy ranges using a silicon PIN photodiode. Br J Radiol 2004; 77:395-404. [PMID: 15121703 DOI: 10.1259/bjr/32514512] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
This work describes the analysis of factors which affect the results of estimation of the electron accelerating potential (kVp) applied to an X-ray tube, through determination of the end point of the energy spectrum of the emitted radiation beam. Measurements have been performed utilizing two spectrometers each with a silicon PIN photodiode: one operating at room temperature, and the other, a high resolution spectrometer, with a Peltier cooler. Both were directly irradiated by different X-ray beams. Both systems work at low voltage and without liquid nitrogen cooling, thus avoiding the drawbacks presented by germanium detectors. Each kVp value was determined by linear regression of the end of the spectrum, so as to give, simultaneously, the best fit to the experimental data and low standard deviation for the kVp value. Detector energy resolution and calibration, counting statistics and high voltage waveform ripple have been investigated in order to establish better experimental conditions and to optimize measurement time. Results of measurements carried out with X-ray tubes connected to single-phase, three-phase or constant potential units, using additional filtration of Cu, Al or Mo (for mammographic beams), are presented. The variations resulted in kVp uncertainties up to 0.1 kV.
Collapse
Affiliation(s)
- R A Terini
- Serviço Técnico de Aplicações Médico-Hospitalares, Instituto de Eletrotécnica e Energia, Universidade de São Paulo, Av. Prof. Luciano Gualberto, 1289, Cidade Universitária, CEP. 05508-010, São Paulo, SP, Brazil
| | | | | | | | | |
Collapse
|
7
|
Silva MC, Herdade SB, Lammoglia P, Costa PR, Terini RA. Determination of the voltage applied to x-ray tubes from the bremsstrahlung spectrum obtained with a silicon PIN photodiode. Med Phys 2000; 27:2617-23. [PMID: 11128315 DOI: 10.1118/1.1318222] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
This work describes a methodology for the obtainment of the electron accelerating potential (kVp) applied to an x-ray tube, through the determination of the end point of the energy spectrum of the radiation emitted by the tube. The measurements have been performed utilizing alternatively two silicon PIN photodiodes, directly irradiated by the x-ray beam. Both were operated at room temperature, with low bias, so avoiding the drawbacks presented by photomultiplier tubes and germanium detectors. The energy calibration of the system was performed with X- and gamma-emitter radioactive sources, which makes the method absolute. Each kVp value was determined by means of a linear regression in the end of the spectrum, to give, simultaneously, a good fit of the straight line to the experimental data and a low standard deviation for the kVp value. Results of the measurements carried out with an x-ray tube connected to a three-phase generator, using additional filtration between 1.5 and 4.0 mm of Cu, are presented. This filtration was used in order to minimize the contribution of low energy photons and to reduce pulse pile-up. Errors determined for the values of kVp are between 0.06 and 0.16 kV, in the potential range from 50 to 100 kV. As an example, the methodology has been applied in the verification of the secondary calibration of a voltage divider, utilized, by its turn, in the tertiary calibration of noninvasive kVp meters. All intrinsic sources of errors involved in the process are discussed and evaluated.
Collapse
Affiliation(s)
- M C Silva
- Instituto de Física, Universidade de São Paulo, SP, Brazil.
| | | | | | | | | |
Collapse
|
8
|
Matsumoto M, Yamamoto A, Honda I, Taniguchi A, Kanamori H. Direct measurement of mammographic x-ray spectra using a CdZnTe detector. Med Phys 2000; 27:1490-502. [PMID: 10947252 DOI: 10.1118/1.599015] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Our purpose is to directly measure mammographic x-ray spectra with collimators and a low-efficiency CdZnTe detector developed recently and to find out the best fit response function of CdZnTe detector to correct the measured spectra. Photon spectra (target Mo or Rh) produced by a mammographic x-ray unit at 25-32 kV and 240 mAs (= 3 times of 80 mAs) and transmitted through 0.03 mm Mo or 0.025 mm Rh filter and object (0.1 mm Al to 0.8 mm Al phantoms) have been analyzed. Since detected spectra were distorted by the response of CdZnTe detector and did not present the true photon spectra, the correction was applied by the stripping procedure. The response function of detector used in this procedure has been determined by the evaluation of interactions (K-escape, coherent scattering, and Compton scattering processes) and incomplete charge collection calculated using the Monte Carlo method. We have used Kalpha1, Kalpha2, Kbeta1, Kbeta2 radiations of Cd, Zn, and Te, respectively and have used the weight function for the incomplete charge collection and have considered Compton scattering. The Monte Carlo simulations were continued by changing the important factors (mean path length of hole lambda(h), dead layer of the CZT crystal and weight factor Wq) of incomplete charge collection until the best fit response function was found out. Corrected photon spectra were compared with the mammographic x-ray spectral data of Bureau of Radiological Health (BRH) measured using a Ge detector. Attenuation curves of aluminum for 25-32 kV were calculated from the corrected photon spectra and compared with the attenuation curves measured using an ionization chamber. These results obtained using the CdZnTe detector agreed with the mammographic x-ray spectral data of BRH and attenuation curves obtained by the ionization chamber.
Collapse
Affiliation(s)
- M Matsumoto
- School of Allied Health Sciences, Faculty of Medicine, Osaka University, Suita City, Japan.
| | | | | | | | | |
Collapse
|
9
|
Matsumoto M, Kubota H, Ozaki Y, Kanamori H. Experimental verification of reverse order of diagnostic X-ray beam quality in voltage-ripple dependence. Med Biol Eng Comput 1995; 33:48-51. [PMID: 7616781 DOI: 10.1007/bf02522945] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
It has been generally expected that, as X-ray tube-voltage ripple increases, the X-ray spectrum shifts to the low photon-energy side, and therefore the mean energy decreases, i.e. the beam quality is softened. This is the normal order. Previous calculation (Birch et al., 1979), however, showed that the beam quality generated by 100% ripple was harder than that by 50% ripple. This is the reverse order, against general expectation. To verify the reverse order, X-ray spectra are measured using a germanium detector system. The measurements are performed with various thicknesses of aluminium object. To obtain large ripples at small tube currents, small-capacity high-voltage cables are made. To perform efficient measurements, the homogeneous sensitive region of the germanium crystal is determined, and detector-collimators with various diameters are prepared. As a result, experimental verification of the reverse order is performed for various thicknesses of object. The reverse order also appears in photon spectra and mean energies calculated using three models from previous work (Kramer, 1923; Birch and Marshall, 1979; Tucker et al., 1991) by inserting the tube-voltage waveforms measured with the authors' system. The experimental results agree well with the results using the Birch-Marshall model. Mean energies reach the minimum levels for the three models at 20-60% ripple, as do the experimental results. The reason for the phenomenon is clarified by qualitative illustration.
Collapse
Affiliation(s)
- M Matsumoto
- School of Allied Health Sciences, Faculty of Medicine, Osaka University, Japan
| | | | | | | |
Collapse
|