1
|
Feng L. Golden-Angle Radial MRI: Basics, Advances, and Applications. J Magn Reson Imaging 2022; 56:45-62. [PMID: 35396897 PMCID: PMC9189059 DOI: 10.1002/jmri.28187] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 03/23/2022] [Accepted: 03/24/2022] [Indexed: 12/21/2022] Open
Abstract
In recent years, golden‐angle radial sampling has received substantial attention and interest in the magnetic resonance imaging (MRI) community, and it has become a popular sampling trajectory for both research and clinical use. However, although the number of relevant techniques and publications has grown rapidly, there is still a lack of a review paper that provides a comprehensive overview and summary of the basics of golden‐angle rotation, the advantages and challenges/limitations of golden‐angle radial sampling, and recommendations in using different types of golden‐angle radial trajectories for MRI applications. Such a review paper is expected to be helpful both for clinicians who are interested in learning the potential benefits of golden‐angle radial sampling and for MRI physicists who are interested in exploring this research direction. The main purpose of this review paper is thus to present an overview and summary about golden‐angle radial MRI sampling. The review consists of three sections. The first section aims to answer basic questions such as: what is a golden angle; how is the golden angle calculated; why is golden‐angle radial sampling useful, and what are its limitations. The second section aims to review more advanced trajectories of golden‐angle radial sampling, including tiny golden‐angle rotation, stack‐of‐stars golden‐angle radial sampling, and three‐dimensional (3D) kooshball golden‐angle radial sampling. Their respective advantages and limitations and potential solutions to address these limitations are also discussed. Finally, the third section reviews MRI applications that can benefit from golden‐angle radial sampling and provides recommendations to readers who are interested in implementing golden‐angle radial trajectories in their MRI studies.
Collapse
Affiliation(s)
- Li Feng
- BioMedical Engineering and Imaging Institute (BMEII) and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| |
Collapse
|
2
|
Ladrova M, Martinek R, Nedoma J, Hanzlikova P, Nelson MD, Kahankova R, Brablik J, Kolarik J. Monitoring and Synchronization of Cardiac and Respiratory Traces in Magnetic Resonance Imaging: A Review. IEEE Rev Biomed Eng 2021; 15:200-221. [PMID: 33513108 DOI: 10.1109/rbme.2021.3055550] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Synchronization of human vital signs, namely the cardiac cycle and respiratory excursions, is necessary during magnetic resonance imaging of the cardiovascular system and the abdominal cavity to achieve optimal image quality with minimized artifacts. This review summarizes techniques currently available in clinical practice, as well as methods under development, outlines the benefits and disadvantages of each approach, and offers some unique solutions for consideration.
Collapse
|
3
|
Lee H, Zhao X, Song HK, Wehrli FW. Self-Navigated Three-Dimensional Ultrashort Echo Time Technique for Motion-Corrected Skull MRI. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:2869-2880. [PMID: 32149683 PMCID: PMC7484857 DOI: 10.1109/tmi.2020.2978405] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Ultrashort echo time (UTE) MRI is capable of detecting signals from protons with very short T2 relaxation times, and thus has potential for skull-selective imaging as a radiation-free alternative to computed tomography. However, relatively long scan times make the technique vulnerable to artifacts from involuntary subject motion. Here, we developed a self-navigated, three-dimensional (3D) UTE pulse sequence, which builds on dual-RF, dual-echo UTE imaging, and a retrospective motion correction scheme for motion-resistant skull MRI. Full echo signals in the second readout serve as a self-navigator that yields a time-course of center of mass, allowing for adaptive determination of motion states. Furthermore, golden-means based k-space trajectory was employed to achieve a quasi-uniform distribution of sampling views on a spherical k-space surface for any subset of the entire data collected, thereby allowing reconstruction of low-resolution images pertaining to each motion state for subsequent estimation of rigid-motion parameters. Finally, the extracted trajectory of the head was used to make the whole k-space datasets motion-consistent, leading to motion-corrected, high-resolution images. Additionally, we posit that hardware-related k-space trajectory errors, if uncorrected, result in obscured bone contrast. Thus, a calibration scan was performed once to measure k-space encoding locations, subsequently used during image reconstruction of actual imaging data. In vivo studies were performed to evaluate the effectiveness of the proposed correction schemes in combination with approaches to accelerated bone-selective imaging. Results illustrating effective removal of motion artifacts and clear depiction of skull bone voxels suggest that the proposed method is robust to intermittent head motions during scanning.
Collapse
|
4
|
Chen Z, Kang L, Xia L, Wang Q, Li Y, Hu X, Liu F, Huang F. Technical Note: Sequential combination of parallel imaging and dynamic artificial sparsity framework for rapid free-breathing golden-angle radial dynamic MRI: K-T ARTS-GROWL. Med Phys 2017; 45:202-213. [DOI: 10.1002/mp.12639] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2017] [Revised: 09/17/2017] [Accepted: 10/18/2017] [Indexed: 12/25/2022] Open
Affiliation(s)
- Zhifeng Chen
- Department of Biomedical Engineering; Zhejiang University; Hangzhou China
| | - Liyi Kang
- Department of Biomedical Engineering; Zhejiang University; Hangzhou China
| | - Ling Xia
- Department of Biomedical Engineering; Zhejiang University; Hangzhou China
- State Key Lab of CAD&CG; Zhejiang University; Hangzhou China
| | - Qiuliang Wang
- Division of Superconducting Magnet Science and Technology; Institute of Electrical Engineering; Chinese Academy of Sciences; Beijing China
| | - Yi Li
- Division of Superconducting Magnet Science and Technology; Institute of Electrical Engineering; Chinese Academy of Sciences; Beijing China
| | - Xinning Hu
- Division of Superconducting Magnet Science and Technology; Institute of Electrical Engineering; Chinese Academy of Sciences; Beijing China
| | - Feng Liu
- School of Information Technology and Electrical Engineering; The University of Queensland; Brisbane QLD Australia
| | | |
Collapse
|
5
|
Stäb D, Bollmann S, Langkammer C, Bredies K, Barth M. Accelerated mapping of magnetic susceptibility using 3D planes-on-a-paddlewheel (POP) EPI at ultra-high field strength. NMR IN BIOMEDICINE 2017; 30:e3620. [PMID: 27763692 DOI: 10.1002/nbm.3620] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2015] [Revised: 07/04/2016] [Accepted: 08/17/2016] [Indexed: 06/06/2023]
Abstract
With the advent of ultra-high field MRI scanners in clinical research, susceptibility based MRI has recently gained increasing interest because of its potential to assess subtle tissue changes underlying neurological pathologies/disorders. Conventional, but rather slow, three-dimensional (3D) spoiled gradient-echo (GRE) sequences are typically employed to assess the susceptibility of tissue. 3D echo-planar imaging (EPI) represents a fast alternative but generally comes with echo-time restrictions, geometrical distortions and signal dropouts that can become severe at ultra-high fields. In this work we assess quantitative susceptibility mapping (QSM) at 7 T using non-Cartesian 3D EPI with a planes-on-a-paddlewheel (POP) trajectory, which is created by rotating a standard EPI readout train around its own phase encoding axis. We show that the threefold accelerated non-Cartesian 3D POP EPI sequence enables very fast, whole brain susceptibility mapping at an isotropic resolution of 1 mm and that the high image quality has sufficient signal-to-noise ratio in the phase data for reliable QSM processing. The susceptibility maps obtained were comparable with regard to QSM values and geometric distortions to those calculated from a conventional 4 min 3D GRE scan using the same QSM processing pipeline. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Daniel Stäb
- The Centre for Advanced Imaging, The University of Queensland, Brisbane, Queensland, Australia
- Department of Diagnostic and Interventional Radiology, University of Würzburg, Würzburg, Germany
| | - Steffen Bollmann
- The Centre for Advanced Imaging, The University of Queensland, Brisbane, Queensland, Australia
| | | | - Kristian Bredies
- Institute for Mathematics and Scientific Computing, University of Graz, Graz, Austria
| | - Markus Barth
- The Centre for Advanced Imaging, The University of Queensland, Brisbane, Queensland, Australia
| |
Collapse
|
6
|
Godenschweger F, Kägebein U, Stucht D, Yarach U, Sciarra A, Yakupov R, Lüsebrink F, Schulze P, Speck O. Motion correction in MRI of the brain. Phys Med Biol 2016; 61:R32-56. [PMID: 26864183 DOI: 10.1088/0031-9155/61/5/r32] [Citation(s) in RCA: 104] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Subject motion in MRI is a relevant problem in the daily clinical routine as well as in scientific studies. Since the beginning of clinical use of MRI, many research groups have developed methods to suppress or correct motion artefacts. This review focuses on rigid body motion correction of head and brain MRI and its application in diagnosis and research. It explains the sources and types of motion and related artefacts, classifies and describes existing techniques for motion detection, compensation and correction and lists established and experimental approaches. Retrospective motion correction modifies the MR image data during the reconstruction, while prospective motion correction performs an adaptive update of the data acquisition. Differences, benefits and drawbacks of different motion correction methods are discussed.
Collapse
Affiliation(s)
- F Godenschweger
- Biomedical Magnetic Resonance, Otto-von-Guericke University, Magdeburg, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Gai ND, Malayeri A, Agarwal H, Evers R, Bluemke D. Evaluation of optimized breath-hold and free-breathing 3D ultrashort echo time contrast agent-free MRI of the human lung. J Magn Reson Imaging 2015; 43:1230-8. [PMID: 26458867 DOI: 10.1002/jmri.25073] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2015] [Accepted: 09/25/2015] [Indexed: 01/11/2023] Open
Abstract
PURPOSE To evaluate an optimized stack of radials ultrashort echo time (UTE) 3D magnetic resonance imaging (MRI) sequence for breath-hold and free-breathing imaging of the human lung. MATERIALS AND METHODS A 3D stack of ultrashort echo time radials trajectory was optimized for coronal and axial lower-resolution breath-hold and higher-resolution free-breathing scans using Bloch simulations. The sequence was evaluated in 10 volunteers, without the use of contrast agents. Signal-to-noise ratio (SNR) mean and 95% confidence interval (CI) were determined from separate signal and noise images in a semiautomated fashion. The four scanning schemes were evaluated for significant differences in image quality using Student's t-test. Ten clinical patients were scanned with the sequence and findings were compared with concomitant computed tomography (CT) in nine patients. Breath-hold 3D spokes images were compared with 3D stack of radials in five volunteers. A Mann-Whitney U-test was performed to test significance in both cases. RESULTS Breath-hold imaging of the entire lung in volunteers was performed with SNR (mean = 42.5 [CI]: 35.5-49.5; mean = 34.3 [CI]: 28.6-40) in lung parenchyma for coronal and axial scans, respectively, which can be used as a quick scout scan. Longer respiratory triggered free-breathing scan enabled high-resolution UTE scanning with mean SNR of 14.2 ([CI]: 12.9-15.5) and 9.2 ([CI]: 8.2-10.2) for coronal and axial scans, respectively. Axial free-breathing scans showed significantly higher image quality (P = 0.008) than the three other scanning schemes. The mean score for comparison with CT was 1.67 (score 0: n = 0; 1: n = 3; 2: n = 6). There was no significant difference between CT and MRI (P = 0.25). 3D stack of radials images were significantly better than 3D spokes images (P < 0.001). CONCLUSION The optimized 3D stack of radials trajectory was shown to provide high-quality MR images of the lung parenchyma without the use of MRI contrast agents. The sequence may offer the possibility of breath-hold imaging and provides greater flexibility in trading off slice thickness and parallel imaging for scan time.
Collapse
Affiliation(s)
- Neville D Gai
- Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland, USA
| | - Ashkan Malayeri
- Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland, USA
| | - Harsh Agarwal
- Philips Research N.A., Briarcliff Manor, New York, USA
| | - Robert Evers
- Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland, USA
| | - David Bluemke
- Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
8
|
Vaillant G, Prieto C, Kolbitsch C, Penney G, Schaeffter T. Retrospective Rigid Motion Correction in k-Space for Segmented Radial MRI. IEEE TRANSACTIONS ON MEDICAL IMAGING 2014; 33:1-10. [PMID: 23782798 DOI: 10.1109/tmi.2013.2268898] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Motion occurring during magnetic resonance imaging acquisition is a major factor of image quality degradation. Self-navigation can help reduce artefacts by estimating motion from the acquired data to enable motion correction. Popular self-navigation techniques rely on the availability of a fully-sampled motion-free reference to register the motion corrupted data with. In the proposed technique, rigid motion parameters are derived using the inherent correlation between radial segments in k-space. The registration is performed exclusively in k-space using the Phase Correlation Method, a popular registration technique in computer vision. Robust and accurate registration has been carried out from radial segments composed of as few as 32 profiles. Successful self-navigation has been performed on 2-D dynamic brain scans corrupted with continuous motion for six volunteers. Retrospective motion correction using the derived self-navigation parameters resulted in significant improvement of image quality compared to the conventional sliding window. This work also demonstrates the benefits of using a bit-reversed ordering scheme to limit undesirable effects specific to retrospective motion correction on radial trajectories. This method provides a fast and efficient mean of measuring rigid motion directly in k-space from dynamic radial data under continuous motion.
Collapse
|
9
|
Feng L, Grimm R, Block KT, Chandarana H, Kim S, Xu J, Axel L, Sodickson DK, Otazo R. Golden-angle radial sparse parallel MRI: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI. Magn Reson Med 2013; 72:707-17. [PMID: 24142845 DOI: 10.1002/mrm.24980] [Citation(s) in RCA: 440] [Impact Index Per Article: 40.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2013] [Revised: 09/12/2013] [Accepted: 09/12/2013] [Indexed: 12/25/2022]
Abstract
PURPOSE To develop a fast and flexible free-breathing dynamic volumetric MRI technique, iterative Golden-angle RAdial Sparse Parallel MRI (iGRASP), that combines compressed sensing, parallel imaging, and golden-angle radial sampling. METHODS Radial k-space data are acquired continuously using the golden-angle scheme and sorted into time series by grouping an arbitrary number of consecutive spokes into temporal frames. An iterative reconstruction procedure is then performed on the undersampled time series where joint multicoil sparsity is enforced by applying a total-variation constraint along the temporal dimension. Required coil-sensitivity profiles are obtained from the time-averaged data. RESULTS iGRASP achieved higher acceleration capability than either parallel imaging or coil-by-coil compressed sensing alone. It enabled dynamic volumetric imaging with high spatial and temporal resolution for various clinical applications, including free-breathing dynamic contrast-enhanced imaging in the abdomen of both adult and pediatric patients, and in the breast and neck of adult patients. CONCLUSION The high performance and flexibility provided by iGRASP can improve clinical studies that require robustness to motion and simultaneous high spatial and temporal resolution. Magn Reson Med 72:707-717, 2014. © 2013 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Li Feng
- Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine New York, New York, USA; Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine New York, New York, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Anderson AG, Velikina J, Block W, Wieben O, Samsonov A. Adaptive retrospective correction of motion artifacts in cranial MRI with multicoil three-dimensional radial acquisitions. Magn Reson Med 2012; 69:1094-103. [PMID: 22760728 DOI: 10.1002/mrm.24348] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2012] [Revised: 04/10/2012] [Accepted: 05/03/2012] [Indexed: 11/11/2022]
Abstract
Despite reduction in imaging times through improved hardware and rapid acquisition schemes, motion artifacts can compromise image quality in magnetic resonance imaging, especially in three-dimensional imaging with its prolonged scan durations. Direct extension of most state-of-the-art two-dimensional rigid body motion compensation techniques to the three-dimensional case is often challenging or impractical due to a significant increase in sampling requirements. This article introduces a novel motion correction technique that is capable of restoring image quality in motion corrupted two-dimensional and three-dimensional radial acquisitions without a priori assumptions about when motion occurs. The navigating properties of radial acquisitions-corroborated by multiple receiver coils-are exploited to detect actual instances of motion. Pseudorandom projection ordering provides flexibility of reconstructing navigator images from the obtained motion-free variable-width subsets for subsequent estimation of rigid body motion parameters by coregistration. The proposed approach does not require any additional navigators or external motion estimation schemes. The capabilities and limitations of the method are described and demonstrated through simulations and representative volunteer cranial acquisitions.
Collapse
Affiliation(s)
- Ashley G Anderson
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA.
| | | | | | | | | |
Collapse
|
11
|
Liu J, Spincemaille P, Codella NCF, Nguyen TD, Prince MR, Wang Y. Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition. Magn Reson Med 2010; 63:1230-7. [PMID: 20432294 DOI: 10.1002/mrm.22306] [Citation(s) in RCA: 97] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A respiratory and cardiac self-gated free-breathing three-dimensional cine steady-state free precession imaging method using multiecho hybrid radial sampling is presented. Cartesian mapping of the k-space center along the slice encoding direction provides intensity-weighted position information, from which both respiratory and cardiac motions are derived. With in plan radial sampling acquired at every pulse repetition time, no extra scan time is required for sampling the k-space center. Temporal filtering based on density compensation is used for radial reconstruction to achieve high signal-to-noise ratio and contrast-to-noise ratio. High correlation between the self-gating signals and external gating signals is demonstrated. This respiratory and cardiac self-gated, free-breathing, three-dimensional, radial cardiac cine imaging technique provides image quality comparable to that acquired with the multiple breath-hold two-dimensional Cartesian steady-state free precession technique in short-axis, four-chamber, and two-chamber orientations. Functional measurements from the three-dimensional cardiac short axis cine images are found to be comparable to those obtained using the standard two-dimensional technique.
Collapse
Affiliation(s)
- Jing Liu
- Cornell Cardiovascular Magnetic Resonance Imaging Laboratory, Radiology Department, Weill Cornell Medical College, New York, New York, USA
| | | | | | | | | | | |
Collapse
|
12
|
Bookwalter CA, Griswold MA, Duerk JL. Multiple overlapping k-space junctions for investigating translating objects (MOJITO). IEEE TRANSACTIONS ON MEDICAL IMAGING 2010; 29:339-349. [PMID: 19709968 PMCID: PMC5793906 DOI: 10.1109/tmi.2009.2029854] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
It is a well-known property in Fourier transform magnetic resonance imaging (MRI) that rigid body translational motion in image space results in linear phase accumulation in k -space. This work describes Multiple Overlapping k-space Junctions for Investigating Translating Objects (MOJITO), a correction scheme based on phase differences at trajectory intersections caused by 2-D alterations in the position of an object during MR imaging. The algorithm allows both detection and correction of motion artifacts caused by 2-D rigid body translational motion. Although similar in concept to navigator echoes, MOJITO does not require a repeating path through k-space, uses k-space data from a broader region of k -space, and uses the repeated data in image reconstruction; this provides the potential for a highly efficient self-navigating motion correction method. Here, the concept and theoretical basis of MOJITO is demonstrated using the continuous sampling BOWTIE trajectory in simulation and MR experiments. This particular trajectory is selected since it is well suited for such an algorithm due to numerous trajectory intersections. Specifically, the validity of the technique in the presence of noise and off-resonance effects is demonstrated through simulation.
Collapse
Affiliation(s)
- Candice A Bookwalter
- Case Center for Imaging Research, Department of Radiology and Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106 USA.
| | | | | |
Collapse
|
13
|
Automatic correction of in-plane bulk motion artifacts in self-navigated radial MRI. Magn Reson Imaging 2008; 26:367-78. [PMID: 18068927 DOI: 10.1016/j.mri.2007.08.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2007] [Revised: 08/03/2007] [Accepted: 08/08/2007] [Indexed: 11/24/2022]
Abstract
Radial MRI is typically used for scans that are sensitive to unavoidable motion. While the translational motion artifact can be easily removed from the radial trajectory data by phase correction, correction of rotational motion still remains a challenge in radial MRI. We present a novel method to refocus the image corrupted by view-to-view motion in the view-interleaved radial MRI data. In this method, the error in rotational view angles was modeled as a polynomial function of the view order and the model parameters were estimated by minimizing the self-navigator image metrics such as image entropy, gradient entropy, normalized gradient squared and mean square difference. Translational motion correction was conducted by aligning the projection profiles. Simulation studies were conducted to demonstrate the robustness of both translational and rotational motion correction methods in different noise levels. The proposed method was successfully applied to correct for motion of healthy subjects. Substantial motion correction with relative error of less than 5% was achieved by using either first- or second-order model with the image metrics. This study demonstrates the potential of the method for motion-sensitive applications.
Collapse
|
14
|
Abstract
The need for ECG gating presents many difficulties in cardiac magnetic resonance imaging (CMRI). Real-time imaging techniques eliminate the need for ECG gating in cine CMRI, but they cannot offer the spatial and temporal resolution provided by segmented acquisition techniques. Previous MR signal-based techniques have demonstrated an ability to provide cardiac gating information; however, these techniques result in decreased imaging efficiency. The purpose of this work was to develop a new "self-gated" (SG) acquisition technique that eliminates these efficiency deficits by extracting the motion synchronization signal directly from the same MR signals used for image reconstruction. Three separate strategies are proposed for deriving the SG signal from data acquired using radial k-space sampling: echo peak magnitude, kymogram, and 2D correlation. The SG techniques were performed on seven normal volunteers. A comparison of the results showed that they provided cine image series with no significant differences in image quality compared to that obtained with conventional ECG gating techniques. SG techniques represent an important practical advance in clinical MRI because they enable the acquisition of high temporal and spatial resolution cardiac cine images without the need for ECG gating and with no loss in imaging efficiency.
Collapse
Affiliation(s)
- Andrew C Larson
- Laboratory of Cardiac Energetics, NHLBI, National Institutes of Health, Department of Health and Human Services, Bethesda, Maryland 20892-1061, USA.
| | | | | | | | | | | |
Collapse
|
15
|
Bernstein MA, Shu Y, Elliott AM. RINGLET motion correction for 3D MRI acquired with the elliptical centric view order. Magn Reson Med 2004; 50:802-12. [PMID: 14523967 DOI: 10.1002/mrm.10584] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
A new rigid-body motion correction algorithm is described that is compatible with 3D image sets acquired with the elliptical centric (EC) view order. With this view order, an annular ring of k-space data is acquired in the ky-kz plane during any short time interval. Images for tracking motion can be reconstructed in the yz-plane from any ring of the acquisition data. In these tracking images, a point source (such as an external marker) shows a characteristic bull's-eye pattern that permits motion monitoring and correction. The true position of the point object is located at the center of the bull's-eye pattern. Cross correlation can be performed to automatically track the positions of markers reconstructed from adjacent rings of k-space. To increase the marker signal, the markers are encased in inductively coupled RF coils. Rigid-body motion in the yz-plane is calculated directly with the Euclidean group for rotation and translation, and corrected by rotating and applying phase shifts to any corrupted rings of data. In the current work we present a theoretical analysis of this method, as well as results of volunteer and controlled phantom experiments that demonstrate its initial feasibility. Although the EC view order has mainly been used for MR angiography (MRA), it can also be used for most 3D acquisitions.
Collapse
|
16
|
Welch EB, Rossman PJ, Felmlee JP, Manduca A. Self-navigated motion correction using moments of spatial projections in radial MRI. Magn Reson Med 2004; 52:337-45. [PMID: 15282816 DOI: 10.1002/mrm.20151] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Interest in radial MRI (also known as projection reconstruction (PR) MRI) has increased recently for uses such as fast scanning and undersampled acquisitions. Additionally, PR acquisitions offer intrinsic advantages over standard two-dimensional Fourier transform (2DFT) imaging with respect to motion of the imaged object. It is well known that aligning each spatial domain projection's center of mass (calculated using the 0th and 1st moments) to the center of the field of view (FOV) corrects shifts caused by in-plane translation. In this work, a previously unrealized ability to determine the in-plane rotational motion of an imaged object using the 2nd moments of the spatial domain projections in conjunction with a specific projection angle acquisition time order is reported. We performed the correction using only the PR data itself acquired with the newly proposed projection angle acquisition time order. With the proposed view angle acquisition order, the acquisition is "self-navigating" with respect to both in-plane translation and rotation. We reconstructed the images using the aligned projections and detected acquisition angles to significantly reduce image artifacts due to such motion. The theory of the correction technique is described, and its effectiveness is demonstrated in phantom and in vivo experiments.
Collapse
Affiliation(s)
- Edward Brian Welch
- MRI Research Laboratory, Department of Diagnostic Radiology, Mayo Clinic, Rochester, Minnesota 55905, USA
| | | | | | | |
Collapse
|
17
|
Abstract
Patient motion, especially respiratory motion, results in various artefacts such as blurring and streaks in tomographic images. The interplay of the movement of the beam aperture and variations of organ anatomy during delivery can create 'hot' and 'cold' spots throughout the field in intensity-modulated radiation therapy (IMRT). Detection and correction of patient motion is extremely important in tomographic imaging and IMRT. Tomographic projection data (sinogram) encode not only the patient anatomy information, but also the intra-scanning motion information. In this paper, we developed an algorithm to detect and correct the in-plane respiratory motion directly in sinogram space. The respiratory motion is modelled as time-varying scaling along the x and y directions. Its effects on the sinogram are discussed. Based on the traces of some nodal points in the sinogram, the intra-scanning motion is determined. The motion correction is also implemented in sinogram space. The motion-corrected sinogram is used for reconstruction by the filtered back-projection (FBP) method. Computer simulations validate the motion detection and correction algorithm. The reconstructed images from the motion-corrected sinogram eliminate the majority of the artefacts. The method could be applied to projection data used in CT and ECT, as well as in tomotherapy delivery modification and dose reconstruction.
Collapse
Affiliation(s)
- Weiguo Lu
- Department of Medical Physics, University of Wisconsin-Madison 53706, USA.
| | | |
Collapse
|
18
|
Udupa JK, Herman GT. Medical image reconstruction, processing, visualization, and analysis: the MIPG perspective. Medical Image Processing Group. IEEE TRANSACTIONS ON MEDICAL IMAGING 2002; 21:281-295. [PMID: 12022617 DOI: 10.1109/tmi.2002.1000253] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
|
19
|
Abstract
A new way to correct magnetic resonance image artifacts resulting from view-dependent phase variations and view-dependent variations in rigid body object translation is presented by exploiting basic properties of the trajectory of radial k-space acquisitions. Simulations, phantom studies, and in vivo experiments are used to demonstrate the feasibility and the utility of this method. While somewhat analogous to navigator echo correction, in which special gradients are interleaved into the imaging sequence so echoes at the center of k-space can be acquired prior to or after collection of the image data, the current method does not require additional new gradient structures within the pulse sequence or increases in scan time. The new method uses the phase information from all collected radial k-space data points rather than only the navigator echo, which permits correction of multiple sources of view-dependent phase variation in the image data. The resultant effect is improved image quality in radial MRI acquisitions. Magn Reson Med 45:277-288, 2001.
Collapse
Affiliation(s)
- A Shankaranarayanan
- Department of Radiology, Case Western Reserve University and University Hospitals of Cleveland, 1100 Euclid Avenue, Cleveland, OH 44106, USA
| | | | | | | |
Collapse
|
20
|
Abstract
Timing inaccuracies between the even and odd echoes lead to the formation of Nyquist ghosts in conventional (blipped) echo-planar imaging (EPI). A fast radial scanning method based on the linogram sampling geometry was designed and implemented. No ghosting effects are seen with this scheme, and correction for timing inaccuracies is performed using simple postprocessing steps before reconstruction.
Collapse
Affiliation(s)
- N Gai
- Department of Radiology, Cornell Medical Center, New York, NY, USA
| | | |
Collapse
|
21
|
Abstract
An alternate scheme for linogram image reconstruction, which is more logical from the viewpoint of its applicability to MRI data, is presented here. As a result, an intermediate step for this method, the direct Fourier method (DFM) gives the same results as the earlier developed general reconstruction algorithm labeled as the linogram method (LM). However, the two differ in the pathways taken to the solution. As a result, an intermediate step for DFM corresponds directly with the geometry of linogram data collected for MRI, in contrast to the LM reconstruction. The two reconstruction methods are delineated within the context of MRI data reconstruction, and applied to reconstruct images from linogram spin-echo data of a physical phantom, obtained on a clinical 1.5 T scanner.
Collapse
Affiliation(s)
- N Gai
- Department of Radiology, University of Pennsylvania, Philadelphia 19104, USA
| | | |
Collapse
|
22
|
Abstract
Chemical shift differences, field inhomogeneity, and gradient nonlinearity result in artifacts in magnetic resonance imaging. Three artifacts are characterized for linogram imaging and it is shown that, based on computer simulations and theory, linogram MRI behaves similarly to 2DFT. A correction technique similar to a scheme for 2DFT imaging based on the Dixon technique and coordinate transform methods is proposed. The algorithm is applied to correct for field inhomogeneity and gradient nonlinearity-induced artifacts in both simulations and images of a clinical phantom. The results show good correlation with the theory. It is concluded that linogram imaging offers certain attractive features of both 2DFT and PR imaging techniques, and is a potentially viable alternative to PR imaging in the presence of field inhomogeneity.
Collapse
Affiliation(s)
- N Gai
- Department of Radiology, University of Pennsylvania, Philadelphia 19104, USA
| | | |
Collapse
|