1
|
Cheon BW, Yoo DH, Shin WG, Choi HJ, Park HJ, Kim JI, Min CH. Development of advanced skin dose evaluation technique using a tetrahedral-mesh phantom in external beam radiotherapy: a Monte Carlo simulation study. Phys Med Biol 2019; 64:165005. [PMID: 31269480 DOI: 10.1088/1361-6560/ab2ef5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Incorrect prediction of skin dose in external beam radiotherapy (EBR) can have normal tissue complication such as acute skin desquamation and skin necrosis. The absorbed dose of skin should be evaluated within basal layer, placed between the epidermis and dermis layers. However, current treatment planning systems (TPS) cannot correctly define the skin layer because of the limitation of voxel resolution in computed tomography (CT). Recently, a new tetrahedral-mesh (TM) phantom was developed to evaluate radiation dose realistically. This study aims to develop a technique to evaluate realistic skin dose using the TM phantom in EBR. The TM phantom was modeled with thin skin layers, including the epidermis, basal layer, and dermis from CT images. Using the Geant4 toolkit, the simulation was performed to evaluate the skin dose according to the radiation treatment conditions. The skin dose was evaluated at a surface depth of 50 µm and 2000 µm. The difference in average skin dose between depths was up to 37%, depending on the thickness and region of the skin to be measured. The results indicate that the skin dose has been overestimated when the skin is evaluated using commercial TPS. Although it is not possible with traditional TPS, our skin dose evaluation technique can realistically express the absorbed dose at thin skin layers from a patient-specific phantom.
Collapse
Affiliation(s)
- Bo-Wi Cheon
- Department of Radiation Convergence Engineering, Yonsei University, Wonju 26493, Republic of Korea
| | | | | | | | | | | | | |
Collapse
|
2
|
Fu HJ, Li CW, Tsai WT, Chang CC, Tsang YW. Skin dose for head and neck cancer patients treated with intensity-modulated radiation therapy(IMRT). Radiat Phys Chem Oxf Engl 1993 2017. [DOI: 10.1016/j.radphyschem.2017.02.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
3
|
Vicoroski N, Espinoza A, Duncan M, Oborn BM, Carolan M, Metcalfe P, Menichelli D, Perevertaylo VL, Lerch MLF, Rosenfeld AB, Petasecca M. Development of a silicon diode detector for skin dosimetry in radiotherapy. Med Phys 2017; 44:5402-5412. [DOI: 10.1002/mp.12469] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2017] [Revised: 06/14/2017] [Accepted: 06/28/2017] [Indexed: 11/06/2022] Open
Affiliation(s)
- Nikolina Vicoroski
- Centre for Medical Radiation Physics; University of Wollongong; Wollongong NSW 2500 Australia
| | - Anthony Espinoza
- Centre for Medical Radiation Physics; University of Wollongong; Wollongong NSW 2500 Australia
| | - Mitchell Duncan
- Centre for Medical Radiation Physics; University of Wollongong; Wollongong NSW 2500 Australia
| | - Bradley M. Oborn
- Centre for Medical Radiation Physics; University of Wollongong; Wollongong NSW 2500 Australia
- Illawarra Cancer Care Centre; Wollongong Hospital; Wollongong NSW 2500 Australia
| | - Martin Carolan
- Centre for Medical Radiation Physics; University of Wollongong; Wollongong NSW 2500 Australia
- Illawarra Cancer Care Centre; Wollongong Hospital; Wollongong NSW 2500 Australia
| | - Peter Metcalfe
- Centre for Medical Radiation Physics; University of Wollongong; Wollongong NSW 2500 Australia
- Illawarra Health and Medical Research Institute - IHMRI; Wollongong NSW 2500 Australia
| | | | | | - Michael L. F. Lerch
- Centre for Medical Radiation Physics; University of Wollongong; Wollongong NSW 2500 Australia
- Illawarra Health and Medical Research Institute - IHMRI; Wollongong NSW 2500 Australia
| | - Anatoly B. Rosenfeld
- Centre for Medical Radiation Physics; University of Wollongong; Wollongong NSW 2500 Australia
- Illawarra Health and Medical Research Institute - IHMRI; Wollongong NSW 2500 Australia
| | - Marco Petasecca
- Centre for Medical Radiation Physics; University of Wollongong; Wollongong NSW 2500 Australia
- Illawarra Health and Medical Research Institute - IHMRI; Wollongong NSW 2500 Australia
| |
Collapse
|
4
|
Initial experiments with gel-water: towards MRI-linac dosimetry and imaging. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2016; 39:921-932. [PMID: 27815727 DOI: 10.1007/s13246-016-0495-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2016] [Accepted: 10/25/2016] [Indexed: 10/20/2022]
Abstract
Tracking the position of a moving radiation detector in time and space during data acquisition can replicate 4D image-guided radiotherapy (4DIGRT). Magnetic resonance imaging (MRI)-linacs need MRI-visible detectors to achieve this, however, imaging solid phantoms is an issue. Hence, gel-water, a material that provides signal for MRI-visibility, and which will in future work, replace solid water for an MRI-linac 4DIGRT quality assurance tool, is discussed. MR and CT images of gel-water were acquired for visualisation and electron density verification. Characterisation of gel-water at 0 T was compared to Gammex-RMI solid water, using MagicPlate-512 (M512) and RMI Attix chamber; this included percentage depth dose, tissue-phantom ratio (TPR20/10), tissue-maximum ratio (TMR), profiles, output factors, and a gamma analysis to investigate field penumbral differences. MR images of a non-powered detector in gel-water demonstrated detector visualisation. The CT-determined gel-water electron density agreed with the calculated value of 1.01. Gel-water depth dose data demonstrated a maximum deviation of 0.7% from solid water for M512 and 2.4% for the Attix chamber, and by 2.1% for TPR20/10 and 1.0% for TMR. FWHM and output factor differences between materials were ≤0.3 and ≤1.4%. M512 data passed gamma analysis with 100% within 2%, 2 mm tolerance for multileaf collimator defined fields. Gel-water was shown to be tissue-equivalent for dosimetry and a feasible option to replace solid water.
Collapse
|
5
|
De Puysseleyr A, Lechner W, De Neve W, Georg D, De Wagter C. Absorbed dose measurements in the build-up region of flattened versus unflattened megavoltage photon beams. Z Med Phys 2016; 26:177-83. [PMID: 27020966 DOI: 10.1016/j.zemedi.2016.02.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2014] [Revised: 02/24/2016] [Accepted: 02/25/2016] [Indexed: 12/01/2022]
Abstract
This study evaluated absorbed dose measurements in the build-up region of conventional (FF) versus flattening filter-free (FFF) photon beams. The absorbed dose in the build-up region of static 6 and 10MV FF and FFF beams was measured using radiochromic film and extrapolation chamber dosimetry for single beams with a variety of field sizes, shapes and positions relative to the central axis. Removing the flattening filter generally resulted in slightly higher relative build-up doses. No considerable impact on the depth of maximum dose was found.
Collapse
Affiliation(s)
- Annemieke De Puysseleyr
- Department of Radiation Oncology and Experimental Cancer Research, Ghent University, Ghent, Belgium.
| | - Wolfgang Lechner
- Department of Radiation Oncology, Medical University of Vienna/AKH Wien, Vienna, Austria; Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Wilfried De Neve
- Department of Radiation Oncology and Experimental Cancer Research, Ghent University, Ghent, Belgium
| | - Dietmar Georg
- Department of Radiation Oncology, Medical University of Vienna/AKH Wien, Vienna, Austria; Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Carlos De Wagter
- Department of Radiation Oncology and Experimental Cancer Research, Ghent University, Ghent, Belgium
| |
Collapse
|
6
|
Reynolds TA, Higgins P. Surface dose measurements with commonly used detectors: a consistent thickness correction method. J Appl Clin Med Phys 2015; 16:358–366. [PMID: 26699319 PMCID: PMC5690169 DOI: 10.1120/jacmp.v16i5.5572] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2015] [Revised: 05/06/2015] [Accepted: 04/29/2015] [Indexed: 11/23/2022] Open
Abstract
The purpose of this study was to review application of a consistent correction method for the solid state detectors, such as thermoluminescent dosimeters (chips (cTLD) and powder (pTLD)), optically stimulated detectors (both closed (OSL) and open (eOSL)), and radiochromic (EBT2) and radiographic (EDR2) films. In addition, to compare measured surface dose using an extrapolation ionization chamber (PTW 30-360) with other parallel plate chambers RMI-449 (Attix), Capintec PS-033, PTW 30-329 (Markus) and Memorial. Measurements of surface dose for 6MV photons with parallel plate chambers were used to establish a baseline. cTLD, OSLs, EDR2, and EBT2 measurements were corrected using a method which involved irradiation of three dosimeter stacks, followed by linear extrapolation of individual dosimeter measurements to zero thickness. We determined the magnitude of correction for each detector and compared our results against an alternative correction method based on effective thickness. All uncorrected surface dose measurements exhibited overresponse, compared with the extrapolation chamber data, except for the Attix chamber. The closest match was obtained with the Attix chamber (-0.1%), followed by pTLD (0.5%), Capintec (4.5%), Memorial (7.3%), Markus (10%), cTLD (11.8%), eOSL (12.8%), EBT2 (14%), EDR2 (14.8%), and OSL (26%). Application of published ionization chamber corrections brought all the parallel plate results to within 1% of the extrapolation chamber. The extrapolation method corrected all solid-state detector results to within 2% of baseline, except the OSLs. Extrapolation of dose using a simple three-detector stack has been demonstrated to provide thickness corrections for cTLD, eOSLs, EBT2, and EDR2 which can then be used for surface dose measurements. Standard OSLs are not recommended for surface dose measurement. The effective thickness method suffers from the subjectivity inherent in the inclusion of measured percentage depth-dose curves and is not recommended for these types of measurements.
Collapse
Affiliation(s)
- Tatsiana A. Reynolds
- Department of Radiation OncologyUniversity of Minnesota Med School‐Twin CitiesMinneapolisMNUSA
| | - Patrick Higgins
- Department of Radiation OncologyUniversity of Minnesota Med School‐Twin CitiesMinneapolisMNUSA
| |
Collapse
|
7
|
Olch AJ, Gerig L, Li H, Mihaylov I, Morgan A. Dosimetric effects caused by couch tops and immobilization devices: Report of AAPM Task Group 176. Med Phys 2014; 41:061501. [DOI: 10.1118/1.4876299] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
8
|
Nakano M, Hill RF, Whitaker M, Kim JH, Kuncic Z. A study of surface dosimetry for breast cancer radiotherapy treatments using Gafchromic EBT2 film. J Appl Clin Med Phys 2012; 13:3727. [PMID: 22584169 PMCID: PMC5716557 DOI: 10.1120/jacmp.v13i3.3727] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2011] [Revised: 01/17/2012] [Accepted: 01/13/2012] [Indexed: 11/26/2022] Open
Abstract
The present study quantified surface doses on several rectangular phantom setups and on curved surface phantoms for a 6 MV photon field using the Attix parallel‐plate chamber and Gafchromic EBT2 film. For the rectangular phantom setups, the surface doses on a homogenous water equivalent phantom and a water equivalent phantom with 60 mm thick lung equivalent material were measured. The measurement on the homogenous phantom setup showed consistency in surface and near‐surface doses between an open field and enhanced dynamic wedge (EDW) fields, whereas physical wedged fields showed small differences. Surface dose measurements made using the EBT2 film showed good agreement with results of the Attix chamber and results obtained in previous studies which used other dosimeters within the measurement uncertainty of 3.3%. The surface dose measurements on the phantom setup with lung equivalent material showed a small increase without bolus and up to 6.9% increase with bolus simulating the increase of chest wall thickness. Surface doses on the cylindrical CT phantom and customized Perspex chest phantom were measured using the EBT2 film with and without bolus. The results indicate the important role of the presence of bolus if the clinical target volume (CTV) is quite close to the surface. Measurements on the cylindrical phantom suggest that surface doses at the oblique positions of 60° and 90° are mainly caused by the lateral scatter from the material inside the phantom. In the case of a single tangential irradiation onto Perspex chest phantom, the distribution of the surface dose with and without bolus materials showed opposing inclination patterns, whereas the dose distribution for two opposed tangential fields gave symmetric dose distribution. This study also demonstrates the suitability of Gafchromic EBT2 film for surface dose measurements in megavoltage photon beams. PACS number: 87.53.Bn
Collapse
Affiliation(s)
- Masahiro Nakano
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, NSW 2006, Australia.
| | | | | | | | | |
Collapse
|
9
|
|
10
|
Hsu SH, Moran JM, Chen Y, Kulasekere R, Roberson PL. Dose discrepancies in the buildup region and their impact on dose calculations for IMRT fields. Med Phys 2010; 37:2043-53. [PMID: 20527537 DOI: 10.1118/1.3377769] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Dose accuracy in the buildup region for radiotherapy treatment planning suffers from challenges in both measurement and calculation. This study investigates the dosimetry in the buildup region at normal and oblique incidences for open and IMRT fields and assesses the quality of the treatment planning calculations. METHODS This study was divided into three parts. First, percent depth doses and profiles (for 5 x 5, 10 x 10, 20 x 20, and 30 x 30 cm2 field sizes at 0 degrees, 45 degrees, and 70 degrees incidences) were measured in the buildup region in Solid Water using an Attix parallel plate chamber and Kodak XV film, respectively. Second, the parameters in the empirical contamination (EC) term of the convolution/ superposition (CVSP) calculation algorithm were fitted based on open field measurements. Finally, seven segmental head-and-neck IMRT fields were measured on a flat phantom geometry and compared to calculations using gamma and dose-gradient compensation (C) indices to evaluate the impact of residual discrepancies and to assess the adequacy of the contamination term for IMRT fields. RESULTS Local deviations between measurements and calculations for open fields were within 1% and 4% in the buildup region for normal and oblique incidences, respectively. The C index with 5%/1 mm criteria for IMRT fields ranged from 89% to 99% and from 96% to 98% at 2 mm and 10 cm depths, respectively. The quality of agreement in the buildup region for open and IMRT fields is comparable to that in nonbuildup regions. CONCLUSIONS The added EC term in CVSP was determined to be adequate for both open and IMRT fields. Due to the dependence of calculation accuracy on (1) EC modeling, (2) internal convolution and density grid sizes, (3) implementation details in the algorithm, and (4) the accuracy of measurements used for treatment planning system commissioning, the authors recommend an evaluation of the accuracy of near-surface dose calculations as a part of treatment planning commissioning.
Collapse
Affiliation(s)
- Shu-Hui Hsu
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109, USA.
| | | | | | | | | |
Collapse
|
11
|
Smith DW, Christophides D, Dean C, Naisbit M, Mason J, Morgan A. Dosimetric characterization of the iBEAM evo carbon fiber couch for radiotherapy. Med Phys 2010; 37:3595-606. [DOI: 10.1118/1.3451114] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
12
|
Hsu SH, Roberson PL, Chen Y, Marsh RB, Pierce LJ, Moran JM. Assessment of skin dose for breast chest wall radiotherapy as a function of bolus material. Phys Med Biol 2008; 53:2593-606. [PMID: 18441412 DOI: 10.1088/0031-9155/53/10/010] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
13
|
Becker SJ, Patel RR, Mackie TR. Increased Skin Dose With the Use of a Custom Mattress for Prone Breast Radiotherapy. Med Dosim 2007; 32:196-9. [PMID: 17707199 DOI: 10.1016/j.meddos.2007.01.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2006] [Revised: 01/17/2007] [Accepted: 01/24/2007] [Indexed: 11/29/2022]
Abstract
The purpose of this study was to measure and compare the loss of buildup to the skin of the breast in the prone position due to 2 different positioning systems during tangential external beam irradiation. Two experiments were performed; one with a standard nylon-covered foam support and another with a novel helium-filled Mylar bag support. The choice of helium-filled Mylar was to reduce the contamination to as low as possible. The experiments were designed to allow a surface dose measurement and a depth dose profile with the pads placed in the path of the beam in front of the detector. All measurements were taken using a Capintec PS-033 thin-window parallel plate ionization chamber. The standard nylon-covered foam pad caused the surface dose to rise as it got closer to the skin. When the pad was directly touching the surface, the surface dose increased by 300% compared to the result when no pad was present. This loss of buildup to the surface was similar to that of a custom bolus material. The opposite effect occurred with the use of the helium-filled Mylar bag, namely the surface dose gradually decreased as the pad got closer to the phantom. When the Mylar pad was directly touching the phantom, the surface dose was decreased by 7% compared to when no pad was present. The use of a foam pad could potentially result in a significant higher dose to the skin, resulting in an enhanced acute skin reaction. Therefore, special care should be taken in this clinical scenario and further investigation of an air- or helium-based mylar support pad should be investigated in the context of definitive breast radiation treatment.
Collapse
Affiliation(s)
- Stewart J Becker
- Department of Medical Physics, University of Wisconsin, Madison, WI, USA.
| | | | | |
Collapse
|
14
|
Ramsey CR, Seibert RM, Robison B, Mitchell M. Helical tomotherapy superficial dose measurements. Med Phys 2007; 34:3286-93. [PMID: 17879792 DOI: 10.1118/1.2757000] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Helical tomotherapy is a treatment technique that is delivered from a 6 MV fan beam that traces a helical path while the couch moves linearly into the bore. In order to increase the treatment delivery dose rate, helical tomotherapy systems do not have a flattening filter. As such, the dose distributions near the surface of the patient may be considerably different from other forms of intensity-modulated delivery. The purpose of this study was to measure the dose distributions near the surface for helical tomotherapy plans with a varying separation between the target volume and the surface of an anthropomorphic phantom. A hypothetical planning target volume (PTV) was defined on an anthropomorphic head phantom to simulate a 2.0 Gy per fraction IMRT parotid-sparing head and neck treatment of the upper neck nodes. A total of six target volumes were created with 0, 1, 2, 3, 4, and 5 mm of separation between the surface of the phantom and the outer edge of the PTV. Superficial doses were measured for each of the treatment deliveries using film placed in the head phantom and thermoluminescent dosimeters (TLDs) placed on the phantom's surface underneath an immobilization mask. In the 0 mm test case where the PTV extends to the phantom surface, the mean TLD dose was 1.73 +/- 0.10 Gy (or 86.6 +/- 5.1% of the prescribed dose). The measured superficial dose decreases to 1.23 +/- 0.10 Gy (61.5 +/- 5.1% of the prescribed dose) for a PTV-surface separation of 5 mm. The doses measured by the TLDs indicated that the tomotherapy treatment planning system overestimates superficial doses by 8.9 +/- 3.2%. The radiographic film dose for the 0 mm test case was 1.73 +/- 0.07 Gy, as compared to the calculated dose of 1.78 +/- 0.05 Gy. Given the results of the TLD and film measurements, the superficial calculated doses are overestimated between 3% and 13%. Without the use of bolus, tumor volumes that extend to the surface may be underdosed. As such, it is recommended that bolus be added for these clinical cases. For cases where the target volume is located 1 to 5 mm below the surface, the tumor volume coverage can be achieved with surface doses ranging from 56% to 93% of the prescribed dose.
Collapse
Affiliation(s)
- Chester R Ramsey
- Department of Radiation Oncology, Thompson Cancer Survival Center, Knoxville, Tennessee 37916, USA.
| | | | | | | |
Collapse
|
15
|
Raaijmakers AJE, Raaymakers BW, van der Meer S, Lagendijk JJW. Integrating a MRI scanner with a 6 MV radiotherapy accelerator: impact of the surface orientation on the entrance and exit dose due to the transverse magnetic field. Phys Med Biol 2007; 52:929-39. [PMID: 17264362 DOI: 10.1088/0031-9155/52/4/005] [Citation(s) in RCA: 120] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
At the UMC Utrecht, in collaboration with Elekta and Philips Research Hamburg, we are developing a radiotherapy accelerator with integrated MRI functionality. The radiation dose will be delivered in the presence of a lateral 1.5 T field. Although the photon beam is not affected by the magnetic field, the actual dose deposition is done by a cascade of secondary electrons and these electrons are affected by the Lorentz force. The magnetic field causes a reduced build-up distance: because the trajectory of the electrons between collisions is curved, the entrance depth in tissue decreases. Also, at tissue-air interfaces an increased dose occurs due to the so-called electron return effect (ERE): electrons leaving tissue will describe a circular path in air and re-enter the tissue yielding a local dose increase. In this paper the impact of a 1.5 T magnetic field on both the build-up distance and the dose increase due to the ERE will be investigated as a function of the angle between the surface and the incident beam. Monte Carlo simulations demonstrate that in the presence of a 1.5 T magnetic field, the surface dose, the build-up distance and the exit dose depend more heavily on the surface orientation than in the case without magnetic field. This is caused by the asymmetrical pointspread kernel in the presence of 1.5 T and the directional behaviour of the re-entering electrons. Simulations on geometrical phantoms show that ERE dose increase at air cavities can be avoided using opposing beams, also when the air-tissue boundary is not perpendicular to the beam. For the more general case in patient anatomies, more problems may arise. Future work will address the possibilities and limitations of opposing beams in combination with IMRT in a magnetic field.
Collapse
Affiliation(s)
- A J E Raaijmakers
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
| | | | | | | |
Collapse
|
16
|
McNiven AL, Mulligan M, Kron T, Battista JJ. The response of prototype plane-parallel ionization chambers in small megavoltage x-ray fields. Med Phys 2006; 33:3997-4004. [PMID: 17153379 DOI: 10.1118/1.2356650] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Accurate small-field dosimetry has become important with the use of multiple small fields in modern radiotherapy treatments such as IMRT and stereotactic radiosurgery. In this study, we investigate the response of a set of prototype plane-parallel ionization chambers, based upon the Exradin T11 chamber, with active volume diameters of 2, 4, 10, and 20 mm, exposed to 6 MV stereotactic radiotherapy x-ray fields. Our goal was to assess their usefulness for accurate small x-ray field dose measurements. The relative ionization response was measured in circular fields (0.5 to 4 cm diameter) as compared to a 10 x 10 cm2 reference field. A large discrepancy (approximately 40%) was found between the relative response in the smallest plane-parallel chamber and other small volume dosimeters (radiochromic film, micro-metal-oxide-semiconductor field-effect transistor and diode) used for comparison. Monte Carlo BEAMnrc simulations were used to simulate the experimental setup in order to investigate the cause of the under-response and to calculate appropriate correction factors that could be applied to experimental measurements. It was found that in small fields, the air cavity of these custom-made research chambers perturbed the secondary electron fluence profile significantly, resulting in decreased fluence within the active volume, which in turn produces a chamber under-response. It is demonstrated that a large correction to the p(fl) correction factor would be required to improve dosimetric accuracy in small fields, and that these factors could be derived using Monte Carlo simulations.
Collapse
Affiliation(s)
- Andrea L McNiven
- Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| | | | | | | |
Collapse
|
17
|
Chung H, Jin H, Dempsey JF, Liu C, Palta J, Suh TS, Kim S. Evaluation of surface and build-up region dose for intensity-modulated radiation therapy in head and neck cancer. Med Phys 2005; 32:2682-9. [PMID: 16193799 DOI: 10.1118/1.1992067] [Citation(s) in RCA: 73] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Despite much development, there remains dosimetric uncertainty in the surface and build-up regions in intensity-modulated radiation therapy treatment plans for head and neck cancers. Experiments were performed to determine the dosimetric discrepancies in the surface and build-up region between the treatment planning system (TPS) prediction and experimental measurement using radiochromic film. A head and neck compression film phantom was constructed from two semicylindrical solid water slabs. Treatment plans were generated using two commercial TPSs (PINNACLE3 and CORVUS) for two cases, one with a shallow (approximately 0.5 cm depth) target and another with a deep (approximately 6 cm depth) target. The plans were evaluated for a 54 Gy prescribed dose. For each case, two pieces of radiochromic film were used for dose measurement. A small piece of film strip was placed on the surface and another was inserted within the phantom. Overall, both TPSs showed good agreement with the measurement. For the shallow target case, the dose differences were within +/- 300 cGy (5.6% with respect to the prescribed dose) for PINNACLE3 and +/- 240 cGy (4.4%) for CORVUS in 90% of the region of interest. For the deep target case, the dose differences were +/- 350 (6.5%) for PINNACLE3 and +/- 260 cGy (4.8%) for CORVUS in 90% of the region of interest. However, it was found that there were significant discrepancies from the surface to about 0.2 cm in depth for both the shallow and deep target cases. It was concluded that both TPSs overestimated the surface dose for both shallow and deep target cases. The amount of overestimation ranges from 400 to 1000 cGy (approximately 7.4% to 18.5% with respect to the prescribed dose, 5400 cGy).
Collapse
Affiliation(s)
- Heeteak Chung
- Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, Florida 32610, USA
| | | | | | | | | | | | | |
Collapse
|
18
|
Paelinck L, De Wagter C, Van Esch A, Duthoy W, Depuydt T, De Neve W. Comparison of build-up dose between Elekta and Varian linear accelerators for high-energy photon beams using radiochromic film and clinical implications for IMRT head and neck treatments. Phys Med Biol 2005; 50:413-28. [PMID: 15773720 DOI: 10.1088/0031-9155/50/3/002] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Skin toxicity has been reported for IMRT of head and neck cancer. The purpose of this study was to investigate the dose in the build-up region delivered by a 6 MV treatment plan for which important skin toxicity was observed. We also investigated if the different designs of the treatment head of an Elekta and a Varian linear accelerator, especially the lower position of the Varian multi-leaf collimator, give rise to different build-up doses. For regular square open beams, the build-up dose along the central beam axis is higher for the Varian machine than for the Elekta machine, both for 6 MV and 18 MV. At the Elekta machine at 18 MV, the superficial dose of a diamond shaped 10 x 10 cm2 field is 3.6% lower than the superficial dose of a regular 10 x 10 cm2 field. This effect is not seen at 6 MV. At the Varian machine, the superficial dose of the diamond shaped field is respectively 3.5 and 14.2% higher than the superficial dose of the regular 10 x 10 cm2 field for 6 MV and 18 MV. Despite the differences measured in build-up dose for single beams between the Elekta and the Varian linear accelerator, there were no measurable differences in superficial dose when a typical IMRT dose plan of 6 MV for a head and neck tumour is executed at the two machines.
Collapse
Affiliation(s)
- L Paelinck
- Ghent University Hospital, De Pintelaan 185, B-9000 Gent, Belgium.
| | | | | | | | | | | |
Collapse
|
19
|
Dogan N, Glasgow GP. Surface and build-up region dosimetry for obliquely incident intensity modulated radiotherapy 6 MV x rays. Med Phys 2003; 30:3091-6. [PMID: 14713075 DOI: 10.1118/1.1625116] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
This study investigates the surface dose and build-up region dosimetry for oblique IMRT beams. The dependence of surface and build-up region doses of 0 degrees (perpendicular incidence) and 75 degrees (oblique incidence) IMRT fields on field size was measured and compared with open field dosimetry. Measurements were performed using a parallel-plate chamber and KODAK EDR2 films in a polystyrene phantom for a 6 cm x 6 cm and a 12 cm x 12 cm, 6 MV photon beam at depths of 0 mm (surface) through dmax. Data were normalized to the dmax value of each field. Four intensity modulated delivery patterns were created and delivered using step-and-shoot IMRT: (1) six static 1 cm x 6 cm strips (IMRTstrip), (2) 12 static 1 cm x 12 cm strips (IMRTstrip), (3) intensity modulated beam patterns created by using the inverse planning optimization software (IMRTopt) for 6 cm x 6 cm, and (4) IMRTopt for 12 cm x 12 cm field sizes. The percent depth doses (PDDs) of 0 degrees, 6 cm x 6 cm IMRTstrip beam at the surface and 5 mm were lower by 8.8% and 1.6%, respectively, compared to the open field. The PDDs of 75 degrees, 6 cm x 6 cm IMRTstrip beam at the surface and 5 mm were lower by 6.7% and 2.4%, respectively, compared to the open field. This study showed that IMRT itself is not contributing to greater skin doses.
Collapse
Affiliation(s)
- Nesrin Dogan
- Loyola University Chicago Medical Center, Department of Radiation Oncology, Maywood, Illinois 60153, USA.
| | | |
Collapse
|
20
|
Carl J, Vestergaard A. Skin damage probabilities using fixation materials in high-energy photon beams. Radiother Oncol 2000; 55:191-8. [PMID: 10799732 DOI: 10.1016/s0167-8140(00)00177-8] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
INTRODUCTION Patient fixation, such as thermoplastic masks, carbon-fibre support plates and polystyrene bead vacuum cradles, is used to reproduce patient positioning in radiotherapy. Consequently low-density materials may be introduced in high-energy photon beams. The aim of the this study was to measure the increase in skin dose when low-density materials are present and calculate the radiobiological consequences in terms of probabilities of early and late skin damage. METHOD An experimental thin-windowed plane-parallel ion chamber was used. Skin doses were measured using various overlaying low-density fixation materials. A fixed geometry of a 10x10 cm field, a SSD=100 cm and photon energies of 4, 6 and 10 MV on Varian Clinac 2100C accelerators were used for all measurements. Radiobiological consequences of introducing these materials into the high-energy photon beams were evaluated in terms of early and late damage of the skin based on the measured surface doses and the LQ-model. RESULTS The experimental ion chamber gave results consistent with other studies. A relationship between skin dose and material thickness in mg/cm(2) was established and used to calculate skin doses in scenarios assuming radiotherapy treatment with opposed fields. CONCLUSION Conventional radiotherapy may apply mid-point doses up to 60-66 Gy in daily 2-Gy fractions opposed fields. Using thermoplastic fixation and high-energy photons as low as 4 MV do increase the dose to the skin considerably. However, using thermoplastic materials with thickness less than 100 mg/cm(2) skin doses are comparable with those produced by variation in source to skin distance, field size or blocking trays within clinical treatment set-ups. The use of polystyrene cradles and carbon-fibre materials with thickness less than 100 mg/cm(2) should be avoided at 4 MV at doses above 54-60 Gy.
Collapse
Affiliation(s)
- J Carl
- Radiophysics Laboratory, Department of Oncology, Aalborg Hospital, Section South, DK-9000, Aalborg, Denmark
| | | |
Collapse
|