Li B, Huang J, Ruan J, Peng Q, Huang S, Li Y, Li F. Dosimetric impact of CT metal artifact reduction for spinal implants in stereotactic body radiotherapy planning. Quant Imaging Med Surg 2023; 13:8290-8302. [PMID: 38106297 PMCID: PMC10721987 DOI: 10.21037/qims-23-442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 09/14/2023] [Indexed: 12/19/2023]
Abstract
Background Metal artifacts due to spinal implants may affect the accuracy of dose calculation for radiotherapy. However, the dosimetric impact of metal artifact reduction (MAR) for spinal implants in stereotactic body radiotherapy (SBRT) plans has not been well studied. The objective of this study was to evaluate the dosimetric impact of MAR in spinal SBRT planning with three clinically common dose calculation algorithms. Methods Gammex phantom and 10 patients' computed tomography (CT) images were studied to investigate the effects of titanium implants. A commercial orthopedic MAR algorithm was employed to reduce artifacts. Dose calculations for SBRT were conducted on both artifact-corrected and uncorrected images using three commercial algorithms [analytical anisotropic algorithm (AAA), Acuros XB (AXB), and Monte Carlo (MC)]. Dose discrepancies between artifact-corrected and uncorrected cases were appraised using a dose-volume histogram (DVH) and 3-dimensional (3D) gamma analysis with different distance to agreement (DTA) and dose difference criteria. The gamma agreement index (GAI) was denoted as G(∆D, DTA). Statistical analysis of t-test was utilized to evaluate the dose differences of different algorithms. Results The phantom study demonstrated that titanium metal artifacts can be effectively reduced. The patient cases study showed that dose differences between the artifact-corrected and uncorrected datasets were small evaluated by gamma index and DVH. Gamma analysis found that even the strict criterion local G(1,1) had average values ≥93.9% for the three algorithms. For all DVH metrics, average differences did not exceed 0.7% in planning target volume (PTV) and 2.1% in planning risk volume of spinal cord (PRV-SC). Statistical analysis showed that the observed dose differences of MC method were significantly larger than those of AAA (P<0.01 for D98% of PTV and P<0.001 for D0.1cc of spinal cord) and AXB methods (P<0.001 for D98% and P<0.0001 for D0.1cc). Conclusions Dosimetric impact of artifacts caused by titanium implants is not significant in spinal SBRT planning, which indicates that dose calculation algorithms might not be very sensitive to CT number variation caused by titanium inserts.
Collapse
Affiliation(s)
- Bin Li
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Jiexing Huang
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
- Department of Radiation Oncology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Junjie Ruan
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Qinghe Peng
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Sijuan Huang
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Yunfei Li
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Fanghua Li
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| |
Collapse
|
2
|
Chen Q, Rong Y, Burmeister JW, Chao EH, Corradini NA, Followill DS, Li XA, Liu A, Qi XS, Shi H, Smilowitz JB. AAPM Task Group Report 306: Quality control and assurance for tomotherapy: An update to Task Group Report 148. Med Phys 2023; 50:e25-e52. [PMID: 36512742 DOI: 10.1002/mp.16150] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 09/22/2022] [Accepted: 11/28/2022] [Indexed: 12/15/2022] Open
Abstract
Since the publication of AAPM Task Group (TG) 148 on quality assurance (QA) for helical tomotherapy, there have been many new developments on the tomotherapy platform involving treatment delivery, on-board imaging options, motion management, and treatment planning systems (TPSs). In response to a need for guidance on quality control (QC) and QA for these technologies, the AAPM Therapy Physics Committee commissioned TG 306 to review these changes and make recommendations related to these technology updates. The specific objectives of this TG were (1) to update, as needed, recommendations on tolerance limits, frequencies and QC/QA testing methodology in TG 148, (2) address the commissioning and necessary QA checks, as a supplement to Medical Physics Practice Guidelines (MPPG) with respect to tomotherapy TPS and (3) to provide risk-based recommendations on the new technology implemented clinically and treatment delivery workflow. Detailed recommendations on QA tests and their tolerance levels are provided for dynamic jaws, binary multileaf collimators, and Synchrony motion management. A subset of TPS commissioning and QA checks in MPPG 5.a. applicable to tomotherapy are recommended. In addition, failure mode and effects analysis has been conducted among TG members to obtain multi-institutional analysis on tomotherapy-related failure modes and their effect ranking.
Collapse
Affiliation(s)
- Quan Chen
- Radiation Oncology, City of Hope Medical Center, Duarte, California, USA
| | - Yi Rong
- Department of Radiation Oncology, Mayo Clinic Hospitals, Phoenix, Arizona, USA
| | - Jay W Burmeister
- Karmanos Cancer Center, Gershenson R.O.C., Detroit, Michigan, USA
- Department of Oncology, Wayne State University School of Medicine, Detroit, Michigan, USA
| | | | | | - David S Followill
- Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - X Allen Li
- Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - An Liu
- Radiation Oncology, City of Hope Medical Center, Duarte, California, USA
| | - X Sharon Qi
- Radiation Oncology, UCLA School of Medicine, Los Angeles, California, USA
| | - Hairong Shi
- Radiation Oncology, Oklahoma Cancer Specialists and Research Institute, Tulsa, Oklahoma, USA
| | - Jennifer B Smilowitz
- Human Oncology and Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
3
|
Müller BS, Ryang YM, Oechsner M, Düsberg M, Meyer B, Combs SE, Wilkens JJ. The dosimetric impact of stabilizing spinal implants in radiotherapy treatment planning with protons and photons: standard titanium alloy vs. radiolucent carbon-fiber-reinforced PEEK systems. J Appl Clin Med Phys 2020; 21:6-14. [PMID: 32476247 PMCID: PMC7484848 DOI: 10.1002/acm2.12905] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2020] [Revised: 04/13/2020] [Accepted: 04/20/2020] [Indexed: 12/17/2022] Open
Abstract
Background Throughout the last years, carbon‐fibre‐reinforced PEEK (CFP) pedicle screw systems were introduced to replace standard titanium alloy (Ti) implants for spinal instrumentation, promising improved radiotherapy (RT) treatment planning accuracy. We compared the dosimetric impact of both implants for intensity modulated proton (IMPT) and volumetric arc photon therapy (VMAT), with the focus on uncertainties in Hounsfield unit assignment of titanium alloy. Methods Retrospective planning was performed on CT data of five patients with Ti and five with CFP implants. Carbon‐fibre‐reinforced PEEK systems comprised radiolucent pedicle screws with thin titanium‐coated regions and titanium tulips. For each patient, one IMPT and one VMAT plan were generated with a nominal relative stopping power (SP) (IMPT) and electron density (ρ) (VMAT) and recalculated onto the identical CT with increased and decreased SP or ρ by ±6% for the titanium components. Results Recalculated VMAT dose distributions hardly deviated from the nominal plans for both screw types. IMPT plans resulted in more heterogeneous target coverage, measured by the standard deviation σ inside the target, which increased on average by 7.6 ± 2.3% (Ti) vs 3.4 ± 1.2% (CFP). Larger SPs lead to lower target minimum doses, lower SPs to higher dose maxima, with a more pronounced effect for Ti screws. Conclusions While VMAT plans showed no relevant difference in dosimetric quality between both screw types, IMPT plans demonstrated the benefit of CFP screws through a smaller dosimetric impact of CT‐value uncertainties compared to Ti. Reducing metal components in implants will therefore improve dose calculation accuracy and lower the risk for tumor underdosage.
Collapse
Affiliation(s)
- Birgit S Müller
- Department of Radiation Oncology, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
| | - Yu-Mi Ryang
- Department of Neurosurgery, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
| | - Markus Oechsner
- Department of Radiation Oncology, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
| | - Mathias Düsberg
- Department of Radiation Oncology, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
| | - Bernhard Meyer
- Department of Neurosurgery, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
| | - Stephanie E Combs
- Department of Radiation Oncology, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany.,Institute of Innovative Radiotherapy, Helmholtz Zentrum München, Neuherberg, Germany
| | - Jan J Wilkens
- Department of Radiation Oncology, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
| |
Collapse
|
4
|
Hu Y, Byrne M, Archibald-Heeren B, Squires M, Teh A, Seiffert K, Cheers S, Wang Y. A Feasibility Study on the Use of TomoTherapy Megavoltage Computed Tomography Images for Palliative Patient Treatment Planning. J Med Phys 2017; 42:163-170. [PMID: 28974863 PMCID: PMC5618464 DOI: 10.4103/jmp.jmp_32_17] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2017] [Revised: 06/12/2017] [Accepted: 06/14/2017] [Indexed: 11/16/2022] Open
Abstract
Dedicated rapid access palliative radiation therapy improves patients' access to care, allowing more timely treatment which would positively impact on quality of life. The TomoTherapy (Accuray, Sunnyvale, CA) system provides megavoltage (MV) fan-beam computed tomography (FBCT) as the image guidance technique, and a module called "statRT" that allows the use of these MV FBCT images for direct planning. The possibility of using this imaging modality for palliative radiotherapy treatment planning is assessed against accepted planning CT standards by performing tests following AAPM TG 66 and an end-to-end measurement. Results have shown that MV FBCT images acquired by TomoTherapy are of sufficient quality for the purpose of target delineation and dose calculation for palliative treatments. Large image noise and extended scan acquisition time are the two main drawbacks, so this imaging modality should only be used for palliative treatments at areas with well-known, easily distinguishable, and relatively immobile targets such as spine and whole brain.
Collapse
Affiliation(s)
- Yunfei Hu
- Radiation Oncology Centres, Gosford, NSW, Australia
| | - Mikel Byrne
- Radiation Oncology Centres, Wahroonga, NSW, Australia
| | | | | | - Amy Teh
- Radiation Oncology Centres, Gosford, NSW, Australia
- Radiation Oncology Centres, Wahroonga, NSW, Australia
| | | | - Sonja Cheers
- Radiation Oncology Centres, Gosford, NSW, Australia
| | - Yang Wang
- Radiation Oncology Centres, Wahroonga, NSW, Australia
| |
Collapse
|
5
|
Giantsoudi D, De Man B, Verburg J, Trofimov A, Jin Y, Wang G, Gjesteby L, Paganetti H. Metal artifacts in computed tomography for radiation therapy planning: dosimetric effects and impact of metal artifact reduction. Phys Med Biol 2017; 62:R49-R80. [DOI: 10.1088/1361-6560/aa5293] [Citation(s) in RCA: 82] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
6
|
Held M, Cremers F, Sneed PK, Braunstein S, Fogh SE, Nakamura J, Barani I, Perez-Andujar A, Pouliot J, Morin O. Assessment of image quality and dose calculation accuracy on kV CBCT, MV CBCT, and MV CT images for urgent palliative radiotherapy treatments. J Appl Clin Med Phys 2016; 17:279-290. [PMID: 27074487 PMCID: PMC5874969 DOI: 10.1120/jacmp.v17i2.6040] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2015] [Revised: 10/27/2015] [Accepted: 11/18/2015] [Indexed: 12/03/2022] Open
Abstract
A clinical workflow was developed for urgent palliative radiotherapy treatments that integrates patient simulation, planning, quality assurance, and treatment in one 30‐minute session. This has been successfully tested and implemented clinically on a linac with MV CBCT capabilities. To make this approach available to all clinics equipped with common imaging systems, dose calculation accuracy based on treatment sites was assessed for other imaging units. We evaluated the feasibility of palliative treatment planning using on‐board imaging with respect to image quality and technical challenges. The purpose was to test multiple systems using their commercial setup, disregarding any additional in‐house development. kV CT, kV CBCT, MV CBCT, and MV CT images of water and anthropomorphic phantoms were acquired on five different imaging units (Philips MX8000 CT Scanner, and Varian TrueBeam, Elekta VersaHD, Siemens Artiste, and Accuray Tomotherapy linacs). Image quality (noise, contrast, uniformity, spatial resolution) was evaluated and compared across all machines. Using individual image value to density calibrations, dose calculation accuracies for simple treatment plans were assessed for the same phantom images. Finally, image artifacts on clinical patient images were evaluated and compared among the machines. Image contrast to visualize bony anatomy was sufficient on all machines. Despite a high noise level and low contrast, MV CT images provided the most accurate treatment plans relative to kV CT‐based planning. Spatial resolution was poorest for MV CBCT, but did not limit the visualization of small anatomical structures. A comparison of treatment plans showed that monitor units calculated based on a prescription point were within 5% difference relative to kV CT‐based plans for all machines and all studied treatment sites (brain, neck, and pelvis). Local dose differences >5% were found near the phantom edges. The gamma index for 3%/3 mm criteria was ≥95% in most cases. Best dose calculation results were obtained when the treatment isocenter was near the image isocenter for all machines. A large field of view and immediate image export to the treatment planning system were essential for a smooth workflow and were not provided on all devices. Based on this phantom study, image quality of the studied kV CBCT, MV CBCT, and MV CT on‐board imaging devices was sufficient for treatment planning in all tested cases. Treatment plans provided dose calculation accuracies within an acceptable range for simple, urgently planned palliative treatments. However, dose calculation accuracy was compromised towards the edges of an image. Feasibility for clinical implementation should be assessed separately and may be complicated by machine specific features. Image artifacts in patient images and the effect on dose calculation accuracy should be assessed in a separate, machine‐specific study. PACS number(s): 87.55.D‐, 87.57.C‐, 87.57.Q‐
Collapse
|
7
|
Held M, Sneed PK, Fogh SE, Pouliot J, Morin O. Feasibility of MV CBCT-based treatment planning for urgent radiation therapy: dosimetric accuracy of MV CBCT-based dose calculations. J Appl Clin Med Phys 2015; 16:458-471. [PMID: 26699575 PMCID: PMC5690985 DOI: 10.1120/jacmp.v16i6.5625] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2015] [Revised: 08/18/2015] [Accepted: 08/25/2015] [Indexed: 11/23/2022] Open
Abstract
Unlike scheduled radiotherapy treatments, treatment planning time and resources are limited for emergency treatments. Consequently, plans are often simple 2D image‐based treatments that lag behind technical capabilities available for nonurgent radiotherapy. We have developed a novel integrated urgent workflow that uses onboard MV CBCT imaging for patient simulation to improve planning accuracy and reduce the total time for urgent treatments. This study evaluates both MV CBCT dose planning accuracy and novel urgent workflow feasibility for a variety of anatomic sites. We sought to limit local mean dose differences to less than 5% compared to conventional CT simulation. To improve dose calculation accuracy, we created separate Hounsfield unit–to–density calibration curves for regular and extended field‐of‐view (FOV) MV CBCTs. We evaluated dose calculation accuracy on phantoms and four clinical anatomical sites (brain, thorax/spine, pelvis, and extremities). Plans were created for each case and dose was calculated on both the CT and MV CBCT. All steps (simulation, planning, setup verification, QA, and dose delivery) were performed in one 30 min session using phantoms. The monitor units (MU) for each plan were compared and dose distribution agreement was evaluated using mean dose difference over the entire volume and gamma index on the central 2D axial plane. All whole‐brain dose distributions gave gamma passing rates higher than 95% for 2%/2 mm criteria, and pelvic sites ranged between 90% and 98% for 3%/3 mm criteria. However, thoracic spine treatments produced gamma passing rates as low as 47% for 3%/3 mm criteria. Our novel MV CBCT‐based dose planning and delivery approach was feasible and time‐efficient for the majority of cases. Limited MV CBCT FOV precluded workflow use for pelvic sites of larger patients and resulted in image clearance issues when tumor position was far off midline. The agreement of calculated MU on CT and MV CBCT was acceptable for all treatment sites. PACS numbers: 87.55.D‐, 87.57.Q‐
Collapse
|
8
|
Yoshikawa H, Roback DM, Larue SM, Nolan MW. DOSIMETRIC CONSEQUENCES OF USING CONTRAST-ENHANCED COMPUTED TOMOGRAPHIC IMAGES FOR INTENSITY-MODULATED STEREOTACTIC BODY RADIOTHERAPY PLANNING. Vet Radiol Ultrasound 2015; 56:687-95. [PMID: 26242716 DOI: 10.1111/vru.12281] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2014] [Revised: 05/11/2015] [Accepted: 05/12/2015] [Indexed: 12/01/2022] Open
Abstract
Potential benefits of planning radiation therapy on a contrast-enhanced computed tomography scan (ceCT) should be weighed against the possibility that this practice may be associated with an inadvertent risk of overdosing nearby normal tissues. This study investigated the influence of ceCT on intensity-modulated stereotactic body radiotherapy (IM-SBRT) planning. Dogs with head and neck, pelvic, or appendicular tumors were included in this retrospective cross-sectional study. All IM-SBRT plans were constructed on a pre- or ceCT. Contours for tumor and organs at risk (OAR) were manually constructed and copied onto both CT's; IM-SBRT plans were calculated on each CT in a manner that resulted in equal radiation fluence. The maximum and mean doses for OAR, and minimum, maximum, and mean doses for targets were compared. Data were collected from 40 dogs per anatomic site (head and neck, pelvis, and limbs). The average dose difference between minimum, maximum, and mean doses as calculated on pre- and ceCT plans for the gross tumor volume was less than 1% for all anatomic sites. Similarly, the differences between mean and maximum doses for OAR were less than 1%. The difference in dose distribution between plans made on CTs with and without contrast enhancement was tolerable at all treatment sites. Therefore, although caution would be recommended when planning IM-SBRT for tumors near "reservoirs" for contrast media (such as the heart and urinary bladder), findings supported the use of ceCT with this dose calculation algorithm for both target delineation and IM-SBRT treatment planning.
Collapse
Affiliation(s)
- Hiroto Yoshikawa
- Department of Environmental and Radiologic Health Sciences, Colorado State University, Fort Collins, CO, 80523
| | - Donald M Roback
- Department of Radiation Oncology, Rex Cancer Center, Raleigh, NC, 27607
| | - Susan M Larue
- Department of Environmental and Radiologic Health Sciences, Colorado State University, Fort Collins, CO, 80523
| | - Michael W Nolan
- Department of Clinical Sciences, Center for Comparative Medicine and Translational Research, North Carolina State University, Raleigh, NC, 27695
| |
Collapse
|