1
|
Ketterling JA, Silverman RH. High-Frequency Multipulse, Plane-Wave Acoustic Contrast Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:934-942. [PMID: 31841408 PMCID: PMC7195994 DOI: 10.1109/tuffc.2019.2960211] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Multipulse (MP) ultrasound contrast agent (UCA) imaging is a method to increase the contrast-to-background (CBR) ratio in regions of blood flow. Plane-wave imaging allows high frame rates, and with high-frequency ultrasound, fine-spatial and temporal resolution. MP and plane-wave imaging have not been applied to high-frequency ultrasound. Here, an 18-MHz linear array was employed to implement the MP methods of pulse inversion (PI) and amplitude modulation (AM) using high-speed, multiangle, compound plane-wave imaging. A flow of the UCA DEFINITY© at a dilution ratio of 2000:1 circulating through a 2-mm-diameter flow channel in a tissue-mimicking phantom was used to characterize CBR and compared with cases of standard, multiangle compound plane-wave imaging. The relative improvement of PI and AM versus standard plane-wave imaging ranged from 5 to 10 dB. The CBR was observed to be stable over a 60-min time duration for a 2000:1 dilution ratio and a 2000:1 dilution ratio provided an optimal CBR.
Collapse
|
2
|
Hayashi R, Allen JS, Chitnis PV, Mamou J, Ketterling JA. Subharmonic Response of Polymer Contrast Agents Based on the Empirical Mode Decomposition. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:2107-2113. [PMID: 27913328 DOI: 10.1109/tuffc.2016.2615047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The subharmonic threshold for ultrasound contrast agents has been defined as a 20-25 dB difference between the fundamental and subharmonic (2/1) spectral components of the backscatter signal. However, this Fourier-based criterion assumes a linear time-invariant signal. A more appropriate criterion for short cycle and frequency-modulated waveforms is proposed with an adaptive signal-processing approach based on the empirical mode decomposition (EMD) method. The signal is decomposed into an orthogonal basis known as intrinsic mode functions (IMFs) and a subharmonic threshold is defined with respect to the energy ratio of the subharmonic IMF component to that of the incident signal. The method is applied to backscatter data acquired from two polymer-shelled contrast agents, Philips (#38, mean diameter 2.0 [Formula: see text]) and Point Biomedical (#12027, mean diameter 3.9 [Formula: see text]). The acoustic backscatter signals are investigated for a single contrast agent subjected to monofrequency (20 MHz, 20 cycles) and chirp (15-25 MHz, 20 cycles) forcing for incident pressures ranging from 0.5 to 2.4 MPa. In comparison to the spectral peak difference (20 dB) criterion, the EMD method is more sensitive in determining subharmonic signals.
Collapse
|
3
|
Volz KR, Evans KD, Kanner CD, Basso DM. Exploring Targeted Contrast-Enhanced Ultrasound to Detect Neural Inflammation. JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY 2016. [DOI: 10.1177/8756479316665865] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Targeted contrast-enhanced ultrasound (TCEUS) is an innovative method of molecular imaging used for detection of inflammatory biomarkers in vivo. By targeting ultrasound contrast to cell adhesion molecules (CAMs), which are known inflammatory markers within neural tissue, a more direct evaluation of neural inflammation can be made. Due to the novel nature of TCEUS, standardized methods of image analysis do not yet exist. Time intensity curve (TIC) shape analysis is currently used in magnetic resonance contrast imaging to determine temporal behavior of perfusion. Therefore, the presented research attempts to determine TIC shape analysis utility in TCEUS imaging by applying it to TCEUS scans targeted to CAMs present in neural inflammation. This was done in an animal model that underwent a traumatic spinal cord injury to induce inflammation ( n = 31). Subjects were divided into four groups, each receiving a TCEUS targeted to a different CAM seven days after surgery (P-selectin, intracellular adhesion molecule 1 [ICAM-1], vascular cell adhesion molecule 1 [VCAM-1], and control). TICs were generated using average pixel intensity within the injured region of the spinal cord. TIC shape analysis found similar curves were produced while targeting P-selectin and VCAM-1, both demonstrating rapid and sustained enhancement. Control injections demonstrated no enhancement. ICAM-1 injections demonstrated limited enhancement and a shape similar to the control.
Collapse
Affiliation(s)
- Kevin R. Volz
- College of Medicine, School of Health and Rehabilitation Science, The Ohio State University, Columbus, OH, USA
| | - Kevin D. Evans
- College of Medicine, School of Health and Rehabilitation Science, The Ohio State University, Columbus, OH, USA
| | - Christopher D. Kanner
- College of Medicine, School of Health and Rehabilitation Science, The Ohio State University, Columbus, OH, USA
| | - D. Michele Basso
- College of Medicine, School of Health and Rehabilitation Science, The Ohio State University, Columbus, OH, USA
| |
Collapse
|
4
|
Shekhar H, Rychak JJ, Doyley MM. Modifying the size distribution of microbubble contrast agents for high-frequency subharmonic imaging. Med Phys 2014; 40:082903. [PMID: 23927358 DOI: 10.1118/1.4813017] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
PURPOSE Subharmonic imaging is of interest for high frequency (>10 MHz) nonlinear imaging, because it can specifically detect the response of ultrasound contrast agents (UCA). However, conventional UCA produce a weak subharmonic response at high frequencies, which limits the sensitivity of subharmonic imaging. We hypothesized that modifying the size distribution of the agent can enhance its high-frequency subharmonic response. The overall goal of this study was to investigate size-manipulated populations of the agent to determine the range of sizes that produce the strongest subharmonic response at high frequencies (in this case, 20 MHz). A secondary goal was to assess whether the number or the volume-weighted size distribution better represents the efficacy of the agent for high-frequency subharmonic imaging. METHODS The authors created six distinct agent size distributions from the native distribution of a commercially available UCA (Targestar-P®). The median (number-weighted) diameter of the native agent was 1.63 μm, while the median diameters of the size-manipulated populations ranged from 1.35 to 2.99 μm. The authors conducted acoustic measurements with native and size-manipulated agent populations to assess their subharmonic response to 20 MHz excitation (pulse duration 1.5 μs, pressure amplitudes 100-398 kPa). RESULTS The results showed a considerable difference between the subharmonic response of the agent populations that were investigated. The subharmonic response peaked for the agent population with a median diameter of 2.15 μm, which demonstrated a subharmonic signal that was 8 dB higher than the native agent. Comparing the subharmonic response of different UCA populations indicated that microbubbles with diameters between 1.3 and 3 μm are the dominant contributors to the subharmonic response at 20 MHz. Additionally, a better correlation was observed between the subharmonic response of the agent and the number-weighted size-distribution (R2=0.98) than with the volume-weighted size distribution (R2=0.53). CONCLUSIONS Modifying the size distribution of the agent appears to be a viable strategy to improve the sensitivity of high-frequency subharmonic imaging. In addition, when the size distribution of the UCA has not been suitably modified, the number-weighted size distribution is a useful parameter to accurately describe the efficacy of the agent for high-frequency subharmonic imaging.
Collapse
Affiliation(s)
- Himanshu Shekhar
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, New York 14627, USA
| | | | | |
Collapse
|
5
|
Paul S, Nahire R, Mallik S, Sarkar K. Encapsulated microbubbles and echogenic liposomes for contrast ultrasound imaging and targeted drug delivery. COMPUTATIONAL MECHANICS 2014; 53:413-435. [PMID: 26097272 PMCID: PMC4470369 DOI: 10.1007/s00466-013-0962-4] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Micron- to nanometer-sized ultrasound agents, like encapsulated microbubbles and echogenic liposomes, are being developed for diagnostic imaging and ultrasound mediated drug/gene delivery. This review provides an overview of the current state of the art of the mathematical models of the acoustic behavior of ultrasound contrast microbubbles. We also present a review of the in vitro experimental characterization of the acoustic properties of microbubble based contrast agents undertaken in our laboratory. The hierarchical two-pronged approach of modeling contrast agents we developed is demonstrated for a lipid coated (Sonazoid™) and a polymer shelled (poly D-L-lactic acid) contrast microbubbles. The acoustic and drug release properties of the newly developed echogenic liposomes are discussed for their use as simultaneous imaging and drug/gene delivery agents. Although echogenicity is conclusively demonstrated in experiments, its physical mechanisms remain uncertain. Addressing questions raised here will accelerate further development and eventual clinical approval of these novel technologies.
Collapse
Affiliation(s)
- Shirshendu Paul
- Department of Mechanical Engineering, University of Delaware, Newark DE 19716, USA
| | - Rahul Nahire
- Department of Pharmaceutical Sciences, North Dakota State University, Fargo ND 58108, USA
| | - Sanku Mallik
- Department of Pharmaceutical Sciences, North Dakota State University, Fargo ND 58108, USA
| | - Kausik Sarkar
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC 20052, USA
| |
Collapse
|
6
|
Paul S, Russakow D, Rodgers T, Sarkar K, Cochran M, Wheatley M. Determination of the interfacial rheological properties of a poly(DL-lactic acid)-encapsulated contrast agent using in vitro attenuation and scattering. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1277-91. [PMID: 23643050 PMCID: PMC3674163 DOI: 10.1016/j.ultrasmedbio.2013.02.004] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2012] [Revised: 02/06/2013] [Accepted: 02/11/2013] [Indexed: 05/22/2023]
Abstract
The stabilizing encapsulation of a microbubble-based ultrasound contrast agent (UCA) critically affects its acoustic properties. Polymers, which behave differently from materials commonly used (i.e., lipids or proteins) for monolayer encapsulation, have the potential for better stability and improved control of encapsulation properties. Air-filled microbubbles coated with poly(DL-lactic acid) (PLA) are characterized here using in vitro acoustic experiments and several models of encapsulation. The interfacial rheological properties of the encapsulation are determined according to each model using attenuation of ultrasound through a suspension of microbubbles. Then the model predictions are compared with scattered non-linear (sub- and second harmonic) responses. For this microbubble population (average diameter, 1.9 μm), the peak in attenuation measurement indicates a weighted-average resonance frequency of 2.5-3 MHz, which, in contrast to other encapsulated microbubbles, is lower than the resonance frequency of a free bubble of similar size (diameter, 1.9 μm). This apparently contradictory result stems from the extremely low surface dilational elasticity (around 0.01-0.07 N/m) and the reduced surface tension of the poly(DL-lactic acid) encapsulation, as well as the polydispersity of the bubble population. All models considered here are shown to behave similarly even in the non-linear regime because of the low surface dilational elasticity value. Pressure-dependent scattering measurements at two different excitation frequencies (2.25 and 3 MHz) revealed strongly non-linear behavior with 25-30 dB and 5-20 dB enhancements in fundamental and second-harmonic responses, respectively, for a contrast agent concentration of 1.33 μg/mL in the suspension. Sub-harmonic responses are registered above a relatively low generation threshold of 100-150 kPa, with up to 20 dB enhancement beyond that pressure. Numerical predictions from all models show good agreement with the experimentally measured fundamental response, but not with the experimental second-harmonic response. The characteristic features of sub-harmonic responses and the steady response beyond the threshold are matched well by model predictions. However, prediction of the threshold value depends on estimated properties and size distribution. The variation in size distribution from sample to sample leads to variation in estimates of encapsulation properties: the lowest estimated value for surface dilational viscosity better predicts the sub-harmonic threshold.
Collapse
Affiliation(s)
- Shirshendu Paul
- Mechanical Engineering, University of Delaware, Newark, DE 19716
| | - Daniel Russakow
- Mechanical Engineering, University of Delaware, Newark, DE 19716
| | - Tyler Rodgers
- Mechanical Engineering, University of Delaware, Newark, DE 19716
| | - Kausik Sarkar
- Mechanical Engineering, University of Delaware, Newark, DE 19716
- Mechanical and Aerospace Engineering, George Washington University, Washington, DC 20052
| | - Michael Cochran
- Biomedical Engineering, Drexel University, Philadelphia, PA 19104
| | | |
Collapse
|
7
|
Zhushma A, Lebedeva N, Sen P, Rubinstein M, Sheiko SS, Dayton PA. A system for acoustical and optical analysis of encapsulated microbubbles at ultrahigh hydrostatic pressures. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2013; 84:055105. [PMID: 23742587 DOI: 10.1063/1.4803158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Acoustics are commonly used for borehole (i.e., oil well) imaging applications, under conditions where temperature and pressure reach extremes beyond that of conventional medical ultrasonics. Recently, there has been an interest in the application of encapsulated microbubbles as borehole contrast agents for acoustic assessment of fluid composition and flow. Although such microbubbles are widely studied under physiological conditions for medical imaging applications, to date there is a paucity of information on the behavior of encapsulated gas-filled microbubbles at high pressures. One major limitation is that there is a lack of experimental systems to assess both optical and acoustic data of micrometer-sized particles data at these extremes. In this paper, we present the design and application of a high-pressure cell designed for acoustical and optical studies of microbubbles at hydrostatic pressures up to 27.5 MPa (271 atm).
Collapse
Affiliation(s)
- Aleksandr Zhushma
- Department of Chemistry, University of North Carolina, Chapel Hill, North Carolina 27599, USA.
| | | | | | | | | | | |
Collapse
|
8
|
Faez T, Emmer M, Kooiman K, Versluis M, van der Steen A, de Jong N. 20 years of ultrasound contrast agent modeling. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2013; 60:7-20. [PMID: 23287909 DOI: 10.1109/tuffc.2013.2533] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
The merits of ultrasound contrast agents (UCAs) were already known in the 1960s. It was, however, not until the 1990s that UCAs were clinically approved and marketed. In these years, it was realized that the UCAs are not just efficient ultrasound scatterers, but that their main constituent, the coated gas microbubble, acts as a nonlinear resonator and, as such, is capable of generating harmonic energy. Subharmonic, ultraharmonic, and higher harmonic frequencies of the transmitted ultrasound frequency have been reported. This opened up new prospects for their use and several detection strategies have been developed to exploit this harmonic energy to discriminate the contrast bubbles from surrounding tissue. This insight created a need for tools to study coated bubble behavior in an ultrasound field and the first models were developed. Since then, 20 years have elapsed, in which a broad range of UCAs and UCA models have been developed. Although the models have helped in understanding the responses of coated bubbles, the influence of the coating has not been fully elucidated to date and UCA models are still being improved. The aim of this review paper is to offer an overview in these developments and indicate future directions for research.
Collapse
Affiliation(s)
- Telli Faez
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands.
| | | | | | | | | | | |
Collapse
|
9
|
Falou O, Jafari Sojahrood A, Kumaradas JC, Kolios MC. Surface modes and acoustic scattering of microspheres and ultrasound contrast agents. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 132:1820-1829. [PMID: 22978909 DOI: 10.1121/1.4740505] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Surface modes of spherical objects subject to ultrasound excitation have been recently proposed to explain experimental measurements of scattering from microspheres and ultrasound contrast agents (UCAs). In this work, the relationship between surface modes and resonance frequencies of microspheres and UCAs is investigated. A finite-element model, built upon the fundamentals of wave propagation and structural mechanics, was introduced and validated against analytical solutions (error <5%). Numerical results showed the existence of a systematic relationship between resonance frequencies and surface modes of a 30 μm microsphere driven at 1-70 MHz. On the contrary, for a 100 nm shelled, 4 μm diameter UCA, no clear relationship between the resonance frequencies and the surface modes was found in the frequency range examined. Instead, the UCA exhibited a collection of complex oscillations, which appear to be a combination of various surface modes and displacements. A study of the effects of varying the shell properties on the backscatter showed the presence of peaks in the backscatter of thick-shelled UCAs, which are not predicted by previous models. In summary, this work presents a systematic effort to examine scattering and surface modes from ultrasound contrast agents using finite-element models.
Collapse
Affiliation(s)
- Omar Falou
- Department of Electrical and Computer Engineering, Ryerson University, 350 Victoria Street, Toronto, Ontario, M5B 2K3, Canada.
| | | | | | | |
Collapse
|
10
|
Shekhar H, Doyley MM. Improving the sensitivity of high-frequency subharmonic imaging with coded excitation: a feasibility study. Med Phys 2012; 39:2049-60. [PMID: 22482626 PMCID: PMC3321054 DOI: 10.1118/1.3694101] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2011] [Revised: 02/23/2012] [Accepted: 02/23/2012] [Indexed: 12/18/2022] Open
Abstract
PURPOSE Subharmonic intravascular ultrasound imaging (S-IVUS) could visualize the adventitial vasa vasorum, but the high pressure threshold required to incite subharmonic behavior in an ultrasound contrast agent will compromise sensitivity-a trait that has hampered the clinical use of S-IVUS. The purpose of this study was to assess the feasibility of using coded-chirp excitations to improve the sensitivity and axial resolution of S-IVUS. METHODS The subharmonic response of Targestar-p(TM), a commercial microbubble ultrasound contrast agent (UCA), to coded-chirp (5%-20% fractional bandwidth) pulses and narrowband sine-burst (4% fractional bandwidth) pulses was assessed, first using computer simulations and then experimentally. Rectangular windowed excitation pulses with pulse durations ranging from 0.25 to 3 μs were used in all studies. All experimental studies were performed with a pair of transducers (20 MHz/10 MHz), both with diameter of 6.35 mm and focal length of 50 mm. The size distribution of the UCA was measured with a Casy(TM) Cell counter. RESULTS The simulation predicted a pressure threshold that was an order of magnitude higher than that determined experimentally. However, all other predictions were consistent with the experimental observations. It was predicted that: (1) exciting the agent with chirps would produce stronger subharmonic response relative to those produced by sine-bursts; (2) increasing the fractional bandwidth of coded-chirp excitation would increase the sensitivity of subharmonic imaging; and (3) coded-chirp would increase axial resolution. The experimental results revealed that subharmonic-to-fundamental ratios obtained with chirps were 5.7 dB higher than those produced with sine-bursts of similar duration. The axial resolution achieved with 20% fractional bandwidth chirps was approximately twice that achieved with 4% fractional bandwidth sine-bursts. CONCLUSIONS The coded-chirp method is a suitable excitation strategy for subharmonic IVUS imaging. At the 20 MHz transmission frequency and 20% fractional bandwidth, coded-chirp excitation appears to represent the ideal tradeoff between subharmonic strength and axial resolution.
Collapse
|
11
|
Sciallero C, Paradossi G, Trucco A. A preliminary in vitro assessment of polymer-shelled microbubbles in contrast-enhanced ultrasound imaging. ULTRASONICS 2012; 52:456-64. [PMID: 22133737 DOI: 10.1016/j.ultras.2011.10.008] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2011] [Revised: 09/27/2011] [Accepted: 10/19/2011] [Indexed: 05/05/2023]
Abstract
This paper focuses on the use of poly (vinyl alcohol)-shelled microbubbles as a contrast agent in ultrasound medical imaging. The objective was an in vitro assessment of the different working conditions and signal processing methods for the visual detection (especially in small vessels) of such microbubbles, while avoiding their destruction. Polymer-shelled microbubbles have recently been proposed as ultrasound contrast agents with some important advantages. The major drawback is a shell that is less elastic than that of the traditional lipidic microbubbles. Weaker echoes are expected, and their detection at low concentrations may be critical. In vitro experiments were performed with a commercial ultrasound scanner equipped with a dedicated acquisition board. A concentration of 100bubbles/mm(3), excitation pressure amplitudes from 120kPa to 320kPa, and a central frequency of 3MHz or 4.5MHz were used. Three multi-pulse techniques (i.e., pulse inversion, contrast pulse sequence based on three transmitted signals, and contrast pulse sequence in combination with the chirp pulse) were compared. The results confirmed that these microbubbles produce a weaker ultrasound response than lipidic bubbles with a reduced second-order nonlinear component. Nevertheless, these microbubbles can be detected by the contrast pulse sequence technique, especially when the chirp pulse is adopted. The best value of the contrast-to-tissue ratio was obtained at an excitation pressure amplitude of 230kPa: although this pressure amplitude is higher than what is typically used for lipidic microbubbles, it does not cause the rupture of the polymeric contrast agent.
Collapse
Affiliation(s)
- C Sciallero
- Department of Biophysical and Electronic Engineering (DIBE), University of Genoa, Via all'Opera Pia 11, Genova 16145, Italy.
| | | | | |
Collapse
|
12
|
Chitnis PV, Lee P, Dayton PA, Mamou J, Ketterling JA. Characterisation of polymer shelled microbubbles in wall less flow phantom using high frequency ultrasound and video microscopy. BUBBLE SCIENCE ENGINEERING AND TECHNOLOGY 2011; 3:73-78. [PMID: 23795208 PMCID: PMC3686316 DOI: 10.1179/1758897911y.0000000005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
A high frequency ultrasound pulse echo system and a video microscope were combined to investigate the relationship between backscatter from polymer shelled ultrasound contrast agents (UCAs) and their diameter. Individual UCAs (manufactured by Point Biomedical or Philips Research) were imaged while being sonicated with 40 MHz tone bursts. The backscatter magnitude produced by the Philips UCAs was proportional to UCA size, which is consistent with theoretically predicted behaviour of encapsulated microbubbles driven at frequencies above resonance. Despite being smaller, the Point UCAs produced a backscatter magnitude twice that of Philips UCAs, indicating that Point UCAs might behave quasi-resonantly when excited at 40 MHz.
Collapse
Affiliation(s)
- P. V. Chitnis
- F. L. Lizzi Center for Biomedical Engineering, Riverside Research 156 William Street, New York, NY 10038, USA
| | - P. Lee
- F. L. Lizzi Center for Biomedical Engineering, Riverside Research 156 William Street, New York, NY 10038, USA
| | - P. A. Dayton
- Department of Biomedical Engineering, University of North Carolina Chapel Hill Campus Box 7575, Chapel Hill, NC 27599, USA
| | - J. Mamou
- F. L. Lizzi Center for Biomedical Engineering, Riverside Research 156 William Street, New York, NY 10038, USA
| | - J. A. Ketterling
- F. L. Lizzi Center for Biomedical Engineering, Riverside Research 156 William Street, New York, NY 10038, USA
| |
Collapse
|
13
|
Chitnis PV, Lee P, Mamou J, Allen JS, Böhmer M, Ketterling JA. Rupture threshold characterization of polymer-shelled ultrasound contrast agents subjected to static overpressure. JOURNAL OF APPLIED PHYSICS 2011; 109:84906-8490610. [PMID: 21580800 PMCID: PMC3094458 DOI: 10.1063/1.3565062] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2010] [Accepted: 02/13/2011] [Indexed: 05/20/2023]
Abstract
Polymer-shelled micro-bubbles are employed as ultrasound contrast agents (UCAs) and vesicles for targeted drug delivery. UCA-based delivery of the therapeutic payload relies on ultrasound-induced shell rupture. The fragility of two polymer-shelled UCAs manufactured by Point Biomedical or Philips Research was investigated by characterizing their response to static overpressure. The nominal diameters of Point and Philips UCAs were 3 μm and 2 μm, respectively. The UCAs were subjected to static overpressure in a glycerol-filled test chamber with a microscope-reticule lid. UCAs were reconstituted in 0.1 mL of water and added over the glycerol surface in contact with the reticule. A video-microscope imaged UCAs as glycerol was injected (5 mL∕h) to vary the pressure from 2 to 180 kPa over 1 h. Neither UCA population responded to overpressure until the rupture threshold was exceeded, which resulted in abrupt destruction. The rupture data for both UCAs indicated three subclasses that exhibited different rupture behavior, although their mean diameters were not statistically different. The rupture pressures provided a measure of UCA fragility; the Philips UCAs were more resilient than Point UCAs. Results were compared to theoretical models of spherical shells under compression. Observed variations in rupture pressures are attributed to shell imperfections. These results may provide means to optimize polymeric UCAs for drug delivery and elucidate associated mechanisms.
Collapse
|
14
|
Haïat G, Berti R, Galaz B, Taulier N, Amman JJ, Urbach W. Two-dimensional simulation of linear wave propagation in a suspension of polymeric microcapsules used as ultrasound contrast agents. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2011; 129:1642-1652. [PMID: 21428527 DOI: 10.1121/1.3543966] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A generation of tissue-specific stable ultrasound contrast agent (UCA) composed of a polymeric capsule with a perfluorocarbone liquid core has become available. Despite promising uses in clinical practice, the acoustical behavior of such UCA suspensions remains unclear. A simulation code (2-D finite-difference time domain, FDTD) already validated for homogeneous particles [Galaz Haiat, Berti, Taulier, Amman and Urbach, (2010). J. Acoust. Soc. Am. 127, 148-154] is used to model the ultrasound propagation in such UCA suspensions at 50 MHz to investigate the sensitivity of the ultrasonic parameters to physical parameters of UCA. The FDTD simulation code is validated by comparison with results obtained using a shell scatterer model. The attenuation coefficient (respectively, the sound velocity) increases (respectively, decreases) from 4.1 to 58.4 dB/cm (respectively, 1495 to 1428 m/s) when the concentration varies between 1.37 and 79.4 mg/ml, while the backscattered intensity increases non-linearly, showing that a concentration of around 30 mg/ml is sufficient to obtain optimal backscattering intensity. The acoustical parameters vary significantly as a function of the membrane thickness, longitudinal and transverse velocity, indicating that mode conversions in the membrane play an important role in the ultrasonic propagation. The results may be used to help manufacturers to conceive optimal liquid-filled UCA suspensions.
Collapse
Affiliation(s)
- Guillaume Haïat
- CNRS (Centre Nationale de la Recherche Scientifique), Université Paris-Est, Laboratoire Modélisation et Simulation Multi-Échelle, UMR (Unité mixte de recherche) 8208 CNRS, 94010 Créteil Cédex, France.
| | | | | | | | | | | |
Collapse
|
15
|
Mamou J, Ketterling JA. Subharmonic analysis using singular-value decomposition of ultrasound contrast agents. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2009; 125:4078-91. [PMID: 19507989 PMCID: PMC2719484 DOI: 10.1121/1.3117384] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Ultrasound contrast agents (UCAs) are designed to be used below 10 MHz, but interest is growing in studying the response of agents to high-frequency ultrasound. In this study, the subharmonic response of polymer-shelled UCAs with a mean diameter of 1.1 mum excited with 40-MHz tone-bursts of 1-20 cycles was analyzed. UCAs were diluted in water and streamed through a flow phantom that permitted single-bubble backscatter events to be acquired at peak-negative pressures from 0.75 to 5.0 MPa. At each exposure condition, 1000 single-bubble-backscatter events were digitized. Subharmonic content at 20 MHz was screened using a conventional and a singular-value-decomposition (SVD) method. The conventional method evaluated each event spectrum individually while the SVD method treated the 1000-event data set at one time. A subharmonic score (SHS) indicative of how much subharmonic content a 1000-event data set contained was computed for both methods. Empirical-simulation results indicated that SHSs obtained from the two methods were linearly related. Also, experimental data with both methods indicated that subharmonic likelihood increased with pulse duration and peaked near 2 MPa. The SVD method also yielded quantitative information about subharmonic events not available with the conventional method.
Collapse
Affiliation(s)
- Jonathan Mamou
- Frederic L. Lizzi Center for Biomedical Engineering, Riverside Research Institute, New York, New York 10038, USA.
| | | |
Collapse
|
16
|
Marston PL. Negative axial radiation forces on solid spheres and shells in a Bessel beam. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2007; 122:3162-3165. [PMID: 18247728 DOI: 10.1121/1.2799501] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Prior computations predict that fluid spheres illuminated by an acoustic Bessel beam can be subjected to a radiation force directed opposite the direction of beam propagation. The prediction of negative acoustic radiation force is extended to the cases of a solid poly(methylmethacrylate) PMMA sphere in water and an empty aluminum spherical shell in water. Compared with the angular scattering patterns for plane wave illumination, the scattering into the back hemisphere is suppressed when the radiation force is negative. This investigation may be helpful in the development of acoustic tweezers and in the development of methods for manipulating objects during space flight.
Collapse
Affiliation(s)
- Philip L Marston
- Department of Physics and Astronomy, Washington State University, Pullman, Washington 99164-2814, USA.
| |
Collapse
|