1
|
Alomari A, Langton C. Comparison of deconvoluted-convoluted reconstituted ultrasound signals with their experimental original in a porous composite, cancellous bone. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2023. [DOI: 10.1016/j.jrras.2022.100519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
2
|
Wear KA. Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:454-482. [PMID: 31634127 PMCID: PMC7050438 DOI: 10.1109/tuffc.2019.2947755] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Ultrasound is now a clinically accepted modality in the management of osteoporosis. The most common commercial clinical devices assess fracture risk from measurements of attenuation and sound speed in cancellous bone. This review discusses fundamental mechanisms underlying the interaction between ultrasound and cancellous bone. Because of its two-phase structure (mineralized trabecular network embedded in soft tissue-marrow), its anisotropy, and its inhomogeneity, cancellous bone is more difficult to characterize than most soft tissues. Experimental data for the dependencies of attenuation, sound speed, dispersion, and scattering on ultrasound frequency, bone mineral density, composition, microstructure, and mechanical properties are presented. The relative roles of absorption, scattering, and phase cancellation in determining attenuation measurements in vitro and in vivo are delineated. Common speed of sound metrics, which entail measurements of transit times of pulse leading edges (to avoid multipath interference), are greatly influenced by attenuation, dispersion, and system properties, including center frequency and bandwidth. However, a theoretical model has been shown to be effective for correction for these confounding factors in vitro and in vivo. Theoretical and phantom models are presented to elucidate why cancellous bone exhibits negative dispersion, unlike soft tissue, which exhibits positive dispersion. Signal processing methods are presented for separating "fast" and "slow" waves (predicted by poroelasticity theory and supported in cancellous bone) even when the two waves overlap in time and frequency domains. Models to explain dependencies of scattering on frequency and mean trabecular thickness are presented and compared with measurements. Anisotropy, the effect of the fluid filler medium (marrow in vivo or water in vitro), phantoms, computational modeling of ultrasound propagation, acoustic microscopy, and nonlinear properties in cancellous bone are also discussed.
Collapse
|
3
|
Thibeaux R, Duval H, Smaniotto B, Vennat E, Néron D, David B. Assessment of the interplay between scaffold geometry, induced shear stresses, and cell proliferation within a packed bed perfusion bioreactor. Biotechnol Prog 2019; 35:e2880. [PMID: 31271252 DOI: 10.1002/btpr.2880] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 05/29/2019] [Accepted: 06/27/2019] [Indexed: 11/12/2022]
Abstract
By favoring cell proliferation and differentiation, perfusion bioreactors proved efficient at optimizing cell culture. The aim of this study was to quantify cell proliferation within a perfusion bioreactor and correlate it to the wall shear stress (WSS) distribution by combining 3-D imaging and computational fluid dynamics simulations.NIH-3T3 fibroblasts were cultured onto a scaffold model made of impermeable polyacetal spheres or Polydimethylsiloxane cubes. After 1, 2, and 3 weeks of culture, constructs were analyzed by micro-computed tomography (μCT) and quantification of cell proliferation was assessed. After 3 weeks, the volume of cells was found four times higher in the stacking of spheres than in the stacking of cube.3D-μCT reconstruction of bioreactors was used as input for the numerical simulations. Using a lattice-Boltzmann method, we simulated the fluid flow within the bioreactors. We retrieved the WSS distribution (PDF) on the scaffolds surface at the beginning of cultivation and correlated this distribution to the local presence of cells after 3 weeks of cultivation. We found that the WSS distributions strongly differ between spheres and cubes even if the porosity and the specific wetted area of the stackings were very similar. The PDF is narrower and the mean WSS is lower for cubes (11 mPa) than for spheres (20 mPa). For the stacking of spheres, the relative occupancy of the surface sites by cells is maximal when WSS is greater than 20 mPa. For cubes, the relative occupancy is maximal when the WSS is lower than 10 mPa. The discrepancies between spheres and cubes are attributed to the more numerous sites in stacking of spheres that may induce 3-D (multi-layered) proliferation.
Collapse
Affiliation(s)
- Roman Thibeaux
- MSSMat, CentraleSupélec, Université Paris Saclay, CNRS, Gif sur Yvette, France
| | - Hervé Duval
- LGPM, CentraleSupélec, Université Paris Saclay, Gif sur Yvette, France
| | | | - Elsa Vennat
- MSSMat, CentraleSupélec, Université Paris Saclay, CNRS, Gif sur Yvette, France
| | - David Néron
- LMT, ENS Paris-Saclay, CNRS, Université Paris-Saclay, Cachan, France
| | - Bertrand David
- MSSMat, CentraleSupélec, Université Paris Saclay, CNRS, Gif sur Yvette, France
| |
Collapse
|
4
|
Hoffmeister BK, Huber MT, Viano AM, Huang J. Characterization of a polymer, open-cell rigid foam that simulates the ultrasonic properties of cancellous bone. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 143:911. [PMID: 29495707 PMCID: PMC5812744 DOI: 10.1121/1.5023219] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Revised: 01/12/2018] [Accepted: 01/16/2018] [Indexed: 05/28/2023]
Abstract
Materials that simulate the ultrasonic properties of tissues are used widely for clinical and research purposes. However, relatively few materials are known to simulate the ultrasonic properties of cancellous bone. The goal of the present study was to investigate the suitability of using a polymer, open-cell rigid foam (OCRF) produced by Sawbones®. Measurements were performed on OCRF specimens with four different densities. Ultrasonic speed of sound and normalized broadband ultrasonic attenuation were measured with a 0.5 MHz transducer. Three backscatter parameters were measured with a 5 MHz transducer: apparent integrated backscatter, frequency slope of apparent backscatter, and normalized mean of the backscatter difference. X-ray micro-computed tomography was used to measure the microstructural characteristics of the OCRF specimens. The trabecular thickness and relative bone volume of the OCRF specimens were similar to those of human cancellous bone, but the trabecular separation was greater. In most cases, the ultrasonic properties of the OCRF specimens were similar to values reported in the literature for cancellous bone, including dependence on density. In addition, the OCRF specimens exhibited an ultrasonic anisotropy similar to that reported for cancellous bone.
Collapse
Affiliation(s)
| | - Matthew T Huber
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Ann M Viano
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Jinsong Huang
- College of Medicine, University of Tennessee Health Science Center, Memphis, Tennessee 38163, USA
| |
Collapse
|
5
|
Alomari AH, Wille ML, Langton CM. Soft-tissue thickness compensation for ultrasound transit time spectroscopy estimated bone volume fraction—an experimental replication study. Biomed Phys Eng Express 2017. [DOI: 10.1088/2057-1976/aa7b47] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
6
|
Rizvi B, Da Silva E, Slatkovska L, Cheung AM, Tavakkoli J, Pejović-Milić A. Technical Note: Bone mineral density measurements of strontium-rich trabecular bone-mimicking phantoms using quantitative ultrasound. Med Phys 2016; 43:5817. [DOI: 10.1118/1.4963805] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
|
7
|
Lee KI. Dependences of quantitative ultrasound parameters on frequency and porosity in water-saturated nickel foams. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2014; 135:EL61-7. [PMID: 25234916 DOI: 10.1121/1.4862878] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The frequency-dependent phase velocity, attenuation coefficient, and backscatter coefficient were measured from 0.8 to 1.2 MHz in 24 water-saturated nickel foams as trabecular-bone-mimicking phantoms. The power law fits to the measurements showed that the phase velocity, the attenuation coefficient, and the backscatter coefficient were proportional to the frequency with exponents n of 0.95, 1.29, and 3.18, respectively. A significant linear correlation was found between the phase velocity at 1.0 MHz and the porosity. In contrast, the best regressions for the normalized broadband ultrasound attenuation and the backscatter coefficient at 1.0 MHz were obtained with the polynomial fits of second order.
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 200-701, Republic of Korea
| |
Collapse
|
8
|
Lee KI. Ultrasonic properties in marrow-filled and water-filled bovine femoral trabecular bones in vitro. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 132:EL296-EL302. [PMID: 23039568 DOI: 10.1121/1.4751989] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Phase velocity and normalized broadband ultrasound attenuation (nBUA) were measured in 22 marrow-filled and water-filled bovine femoral trabecular bone samples. Replacement of marrow by water led to a significant increase in the mean phase velocity of 47 ± 12 m/s (+3.1%), but a decrease in the mean nBUA of 10.4 ± 2.9 dB/cm/MHz (-38.9%). All the ultrasonic properties in the marrow-filled and water-filled samples exhibited significant negative Pearson's correlation coefficients of r = -0.87 to -0.92 with porosity. High correlations were also observed between pairs of the ultrasonic properties, with r = 0.85 to 0.93.
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 200-701, Republic of Korea.
| |
Collapse
|
9
|
Il Lee K, Joo Choi M. Frequency-dependent attenuation and backscatter coefficients in bovine trabecular bone from 0.2 to 1.2 MHz. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 131:EL67-73. [PMID: 22280732 DOI: 10.1121/1.3671064] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The frequency-dependent attenuation and backscatter coefficients were measured in 25 bovine femoral trabecular bone samples from 0.2 to 1.2 MHz. When the average attenuation coefficient was fitted to a nonlinear power law α(f)=α(0)+α(1)f(n), the exponent n was found to be 1.65. In contrast, the average backscatter coefficient was fitted to a power law η(f)=η(1)f(n) and the exponent n was measured as 3.25. The apparent bone density was significantly correlated with the parameter α(1) (0.2-0.7 MHz: r = 0.852, 0.6-1.2 MHz: r = 0.832) as well as the backscatter coefficient (0.5 MHz: r = 0.751, 1.0 MHz: r = 0.808).
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 200-701, Republic of Korea
| | | |
Collapse
|
10
|
Aygün H, Attenborough K, Lauriks W, Langton CM. Ultrasonic wave propagation in stereo-lithographical bone replicas. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2010; 127:3781-3789. [PMID: 20550276 DOI: 10.1121/1.3397581] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Predictions of a modified anisotropic Biot-Allard theory are compared with measurements of pulses centered on 100 kHz and 1 MHz transmitted through water-saturated stereo-lithographical bone replicas. The replicas are 13 times larger than the original bone samples. Despite the expected effects of scattering, which is neglected in the theory, at 100 kHz the predicted and measured transmitted waveforms are similar. However, the magnitude of the leading negative edge of the waveform is overpredicted, and the trailing parts of the waveforms are not predicted well. At 1 MHz, although there are differences in amplitudes, the theory predicts that the transmitted waveform is almost a scaled version of that incident in conformity with the data.
Collapse
Affiliation(s)
- Haydar Aygün
- Medical Physics, Post-Graduate Medical Institute, The University of Hull, Cottingham Road, Hull HU6 7RX, United Kingdom
| | | | | | | |
Collapse
|
11
|
Culjat MO, Goldenberg D, Tewari P, Singh RS. A review of tissue substitutes for ultrasound imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2010; 36:861-73. [PMID: 20510184 DOI: 10.1016/j.ultrasmedbio.2010.02.012] [Citation(s) in RCA: 353] [Impact Index Per Article: 23.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2009] [Revised: 02/03/2010] [Accepted: 02/22/2010] [Indexed: 05/05/2023]
Abstract
The characterization and calibration of ultrasound imaging systems requires tissue-mimicking phantoms with known acoustic properties, dimensions and internal features. Tissue phantoms are available commercially for a range of medical applications. However, commercial phantoms may not be suitable in ultrasound system design or for evaluation of novel imaging techniques. It is often desirable to have the ability to tailor acoustic properties and phantom configurations for specific applications. A multitude of tissue-mimicking materials and phantoms are described in the literature that have been created using a variety of materials and preparation techniques and that have modeled a range of biological systems. This paper reviews ultrasound tissue-mimicking materials and phantom fabrication techniques that have been developed over the past four decades, and describes the benefits and disadvantages of the processes. Both soft tissue and hard tissue substitutes are explored.
Collapse
Affiliation(s)
- Martin O Culjat
- Center for Advanced Surgical and Interventional Technology (CASIT), UCLA, Los Angeles, CA, USA.
| | | | | | | |
Collapse
|
12
|
Haïat G, Naili S. Independent scattering model and velocity dispersion in trabecular bone: comparison with a multiple scattering model. Biomech Model Mechanobiol 2010; 10:95-108. [PMID: 20490887 DOI: 10.1007/s10237-010-0220-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2009] [Accepted: 04/26/2010] [Indexed: 10/19/2022]
|
13
|
Le LH, Zhang C, Ta D, Lou E. Measurement of tortuosity in aluminum foams using airborne ultrasound. ULTRASONICS 2010; 50:1-5. [PMID: 19720388 DOI: 10.1016/j.ultras.2009.07.011] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2009] [Revised: 05/29/2009] [Accepted: 07/28/2009] [Indexed: 05/10/2023]
Abstract
The slow compressional wave in air-saturated aluminum foams was studied by means of ultrasonic transverse transmission method over a frequency range from 0.2 MHz to 0.8 MHz. The samples investigated have three different cell sizes or pores per inch (5, 10 and 20 ppi) and each size has three aluminum volume fractions (5%, 8% and 12% AVF). Phase velocities show minor dispersion at low frequencies but remain constant after 0.7 MHz. Pulse broadening and amplitude attenuation are obvious and increase with increasing ppi. Attenuation increases considerably with AVF for 20 ppi foams. Tortuosity ranges from 1.003 to 1.032 and increases with AVF and ppi. However, the increase of tortuosity with AVF is very small for 10 and 20 ppi samples.
Collapse
Affiliation(s)
- Lawrence H Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, AB, Canada T6G 2B7.
| | | | | | | |
Collapse
|
14
|
Haïat G, Lhémery A, Renaud F, Padilla F, Laugier P, Naili S. Velocity dispersion in trabecular bone: influence of multiple scattering and of absorption. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2008; 124:4047-58. [PMID: 19206827 DOI: 10.1121/1.3003077] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Speed of sound measurements are widely used clinically to assess bone strength. Trabecular bone is an attenuating composite material in which negative values of velocity dispersion have been measured, this behavior remaining poorly explained physically. The aim of this work is to describe the ultrasonic propagation in trabecular bone modeled by infinite cylinders immersed in a saturating matrix, and to derive the physical determinants of velocity dispersion. A homogenization model accounting for the coupling of multiple scattering and absorption phenomena allows the computation of phase velocity and of dispersion while varying bone properties. The present model is adapted from the generalized self-consistent method developed in the work of Yang and Mal [(1994). "Multiple-scattering of elastic waves in a fiber-reinforced composite," J. Mech. Phys. Solids 42, 1945-1968]. It predicts negative values of velocity dispersion, in agreement with experimental results obtained in phantoms mimicking trabecular bone. In trabecular bone, mostly negative and also positive values of velocity dispersion are predicted by the model, which span within the range of values measured experimentally. Scattering effects are responsible for the negative values of dispersion, whereas the frequency dependence of the absorption coefficient in bone marrow and/or in the trabeculae results in an increase in dispersion, which may then become positive.
Collapse
Affiliation(s)
- G Haïat
- CNRS, Laboratoire de Recherches Orthopédiques, UMR CNRS 7052 B2OA, Paris, France.
| | | | | | | | | | | |
Collapse
|
15
|
Falco EE, Patel M, Fisher JP. Recent Developments in Cyclic Acetal Biomaterials for Tissue Engineering Applications. Pharm Res 2008; 25:2348-56. [DOI: 10.1007/s11095-008-9620-5] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2008] [Accepted: 04/29/2008] [Indexed: 10/22/2022]
|